1
|
Chopra S, Balkhandia M, Khatak M, Sagar N, Agrawal VV. Molecularly imprinted electrochemical sensor based on APTES-functionalized indium tin oxide electrode for the determination of sulfadiazine. Mikrochim Acta 2024; 191:727. [PMID: 39499340 DOI: 10.1007/s00604-024-06781-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Accepted: 10/15/2024] [Indexed: 11/07/2024]
Abstract
An electrochemical sensor was developed for the sensitive and selective detection of sulfadiazine (SDZ), based on a molecularly imprinted polymer (MIP) film formed on an indium tin oxide (ITO) electrode through a self-assembly process. The SDZ-imprinted ITO electrode (SDZ-MIP/APTES-ITO) was prepared through in situ polymerization using sulfadiazine, methacrylic acid (MAA), ethylene glycol dimethacrylate (EGDMA), and 2,2'-azobisisobutyronitrile (AIBN) as the template, functional monomer, cross-linker, and initiator respectively. Before polymerization, the ITO electrode was functionalized with 3-aminopropyltriethoxysilane (APTES) to promote covalent attachment of the polymer to the electrode. After polymerization, the template molecule SDZ was removed to create selective recognition sites, forming the molecularly imprinted polymer electrode (MIP/APTES-ITO), which facilitates sulfadiazine detection. The sensor's performance was evaluated using cyclic and differential pulse voltammetry, demonstrating a linear response in the sulfadiazine concentration range 0.1 to 300 μM, with a detection limit of 0.11 μM. The MIP-based sensor exhibited good reproducibility, repeatability, selectivity, and stability in sulfadiazine detection. Its practical applicability was confirmed by the successful quantification of sulfadiazine in spiked milk samples.
Collapse
Affiliation(s)
- Samridhi Chopra
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Human Resource Development Centre, (CSIR-HRDC) Campus, Postal Staff College Area, Sector 19, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh, 201002, India
- CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, 110012, India
| | - Manisha Balkhandia
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Human Resource Development Centre, (CSIR-HRDC) Campus, Postal Staff College Area, Sector 19, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh, 201002, India
- CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, 110012, India
| | - Manisha Khatak
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Human Resource Development Centre, (CSIR-HRDC) Campus, Postal Staff College Area, Sector 19, Kamla Nehru Nagar, Ghaziabad, Uttar Pradesh, 201002, India
- CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, 110012, India
| | - Navya Sagar
- Amity University, Sector 125, Noida, Uttar Pradesh, 201301, India
| | - Ved Varun Agrawal
- CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, 110012, India.
| |
Collapse
|
2
|
Elamin MB, Ali SMA, Essousi H, Chrouda A, Alhaidari LM, Jaffrezic-Renault N, Barhoumi H. An Electrochemical Sensor for Sulfadiazine Determination Based on a Copper Nanoparticles/Molecularly Imprinted Overoxidized Polypyrrole Composite. SENSORS (BASEL, SWITZERLAND) 2023; 23:1270. [PMID: 36772311 PMCID: PMC9919664 DOI: 10.3390/s23031270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 01/12/2023] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
To protect consumers from risks related to overexposure to sulfadiazine, total residues of this antibacterial agent in animal-origin foodstuffs not exceed international regulations. To this end, a new electrochemical sensor based on a molecularly imprinted polymer nanocomposite using overoxidized polypyrrole and copper nanoparticles for the detection of sulfadiazine is elaborated. After optimization of the preparation of the electrochemical sensors, their differential pulse voltammetric signal exhibits an excellent stability and reproducibility at 1.05 V, with a large linear range between 10-9 and 10-5 mol L-1 and a low detection limit of 3.1 × 10-10 mol L-1. The produced sulfadiazine sensor was successfully tested in real milk samples. The combination of the properties of the electrical conduction of copper nanoparticles with the properties of the preconcentration of the molecularly imprinted overoxidized polypyrrole allows for the highly sensitive detection of sulfadiazine, even in real milk samples. This strategy is new and leads to the lowest detection limit yet achieved, compared to those of the previously published sulfadiazine electrochemical sensors.
Collapse
Affiliation(s)
- Manahil Babiker Elamin
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, Majmaah 11952, Saudi Arabia
| | | | - Houda Essousi
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, Monastir University, Monastir 5000, Tunisia
| | - Amani Chrouda
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, Majmaah 11952, Saudi Arabia
| | - Laila M. Alhaidari
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, Majmaah 11952, Saudi Arabia
| | | | - Houcine Barhoumi
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, Monastir University, Monastir 5000, Tunisia
| |
Collapse
|
3
|
3D-nanocubes of N-doped carbon quantum dots adorned manganese oxide: A functional electrocatalyst for the sensitive detection of sulfadiazine. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.129141] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
4
|
Ayankojo AG, Reut J, Nguyen VBC, Boroznjak R, Syritski V. Advances in Detection of Antibiotic Pollutants in Aqueous Media Using Molecular Imprinting Technique-A Review. BIOSENSORS 2022; 12:bios12070441. [PMID: 35884244 PMCID: PMC9312920 DOI: 10.3390/bios12070441] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/16/2022] [Accepted: 06/21/2022] [Indexed: 05/08/2023]
Abstract
Antibiotics constitute one of the emerging categories of persistent organic pollutants, characterised by their expansion of resistant pathogens. Antibiotic pollutants create a major public health challenge, with already identifiable detrimental effects on human and animal health. A fundamental aspect of controlling and preventing the spread of pollutants is the continuous screening and monitoring of environmental samples. Molecular imprinting is a state-of-the-art technique for designing robust biomimetic receptors called molecularly imprinted polymers (MIPs), which mimic natural biomolecules in target-selective recognition. When integrated with an appropriate sensor transducer, MIP demonstrates a potential for the needed environmental monitoring, thus justifying the observed rise in interest in this field of research. This review examines scientific interventions within the last decade on the determination of antibiotic water pollutants using MIP receptors interfaced with label-free sensing platforms, with an expanded focus on optical, piezoelectric, and electrochemical systems. Following these, the review evaluates the analytical performance of outstanding MIP-based sensors for environmentally significant antibiotics, while highlighting the importance of computational chemistry in functional monomer selection and the strategies for signal amplification and performance improvement. Lastly, the review points out the future trends in antibiotic MIP research, as it transits from a proof of concept to the much demanded commercially available entity.
Collapse
|
5
|
Wasąg J, Grabarczyk M. Copper Film Modified Glassy Carbon Electrode and Copper Film with Carbon Nanotubes Modified Screen-Printed Electrode for the Cd(II) Determination. MATERIALS 2021; 14:ma14185148. [PMID: 34576372 PMCID: PMC8466203 DOI: 10.3390/ma14185148] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/03/2021] [Accepted: 09/06/2021] [Indexed: 11/16/2022]
Abstract
A copper film modified glassy carbon electrode (CuF/GCE) and a novel copper film with carbon nanotubes modified screen-printed electrode (CuF/CN/SPE) for anodic stripping voltammetric measurement of ultratrace levels of Cd(II) are presented. During the development of the research procedure, several main parameters were investigated and optimized. The optimal electroanalytical performance of the working electrodes was achieved in electrolyte 0.1 M HCl and 2 × 10−4 M Cu(II). The copper film modified glassy carbon electrode exhibited operation in the presence of dissolved oxygen with a calculated limit of detection of 1.7 × 10−10 M and 210 s accumulation time, repeatability with RSD of 4.2% (n = 5). In the case of copper film with carbon nanotubes modified screen-printed electrode limit of detection amounted 1.3 × 10−10 M for accumulation time of 210 s and with RSD of 4.5% (n = 5). The calibration curve has a linear range in the tested concentration of 5 × 10−10–5 × 10−7 M (r = 0.999) for CuF/GCE and 3 × 10−10–3 × 10−7 M (r = 0.999) for CuF/CN/SPE with 210 s accumulation time in both cases. The used electrodes enable trace determination of cadmium in different environmental water samples containing organic matrix. The validation of the proposed procedures was carried out through analysis certified reference materials: TM-25.5, SPS-SW1, and SPS-WW1.
Collapse
Affiliation(s)
- Joanna Wasąg
- Department of Materials Engineering, Institute of Engineering and Technical Sciences, Faculty of Natural Sciences and Health, The John Paul II Catholic University of Lublin, 20-950 Lublin, Poland
- Correspondence:
| | - Malgorzata Grabarczyk
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, 20-031 Lublin, Poland;
| |
Collapse
|
6
|
Cardoso AR, Frasco MF, Serrano V, Fortunato E, Sales MGF. Molecular Imprinting on Nanozymes for Sensing Applications. BIOSENSORS 2021; 11:152. [PMID: 34067985 PMCID: PMC8152260 DOI: 10.3390/bios11050152] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 04/29/2021] [Accepted: 05/07/2021] [Indexed: 06/12/2023]
Abstract
As part of the biomimetic enzyme field, nanomaterial-based artificial enzymes, or nanozymes, have been recognized as highly stable and low-cost alternatives to their natural counterparts. The discovery of enzyme-like activities in nanomaterials triggered a broad range of designs with various composition, size, and shape. An overview of the properties of nanozymes is given, including some examples of enzyme mimics for multiple biosensing approaches. The limitations of nanozymes regarding lack of selectivity and low catalytic efficiency may be surpassed by their easy surface modification, and it is possible to tune specific properties. From this perspective, molecularly imprinted polymers have been successfully combined with nanozymes as biomimetic receptors conferring selectivity and improving catalytic performance. Compelling works on constructing imprinted polymer layers on nanozymes to achieve enhanced catalytic efficiency and selective recognition, requisites for broad implementation in biosensing devices, are reviewed. Multimodal biomimetic enzyme-like biosensing platforms can offer additional advantages concerning responsiveness to different microenvironments and external stimuli. Ultimately, progress in biomimetic imprinted nanozymes may open new horizons in a wide range of biosensing applications.
Collapse
Affiliation(s)
- Ana R. Cardoso
- BioMark@UC, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal; (A.R.C.); (M.F.F.); (V.S.)
- BioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal
- CEB, Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal
- i3N/CENIMAT, Department of Materials Science, Faculty of Sciences and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, 2829-516 Caparica, Portugal;
| | - Manuela F. Frasco
- BioMark@UC, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal; (A.R.C.); (M.F.F.); (V.S.)
- BioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal
- CEB, Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal
| | - Verónica Serrano
- BioMark@UC, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal; (A.R.C.); (M.F.F.); (V.S.)
- BioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal
- CEB, Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal
| | - Elvira Fortunato
- i3N/CENIMAT, Department of Materials Science, Faculty of Sciences and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, 2829-516 Caparica, Portugal;
| | - Maria Goreti Ferreira Sales
- BioMark@UC, Faculty of Sciences and Technology, University of Coimbra, 3030-790 Coimbra, Portugal; (A.R.C.); (M.F.F.); (V.S.)
- BioMark@ISEP, School of Engineering, Polytechnic Institute of Porto, 4249-015 Porto, Portugal
- CEB, Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal
| |
Collapse
|