1
|
Wang C, Zhang J, Pei Y, Li C, Li Y, Chen S, Wang Z. Visualized electrochemiluminescence detection of trace copper in practical food samples. Food Chem 2024; 451:139461. [PMID: 38701733 DOI: 10.1016/j.foodchem.2024.139461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 04/09/2024] [Accepted: 04/21/2024] [Indexed: 05/05/2024]
Abstract
Copper as a widely applied element in food supply chain can cause serious contamination issues that threats food safety. In this research, we present a quick and visible method for trace copper ion (Cu2+) quantification in practical food samples. Polymer dots (Pdots) were firstly conjugated with a copper-specific DNA aptamer and then tailored with rhodamine B (RhB) to extinguish the electrochemiluminescence (ECL) signal through a resonance energy transfer process. The selective release of RhB leads to signal restoration when exposed to trace Cu2+ levels, achieving remarkable linearity with the logarithm of Cu2+ concentration within the range of 1 ng/L to 10 μg/L with an impressively low limit of detection at 11.8 pg/L. Most notably, our device was also applicable on visualizing and quantifying trace Cu2+ (∼0.2 μg/g) in practical Glycyrrhiza uralensis Fisch. samples, underscoring its potential as a tool for the early prevention of potential copper contamination in food samples.
Collapse
Affiliation(s)
- Cheng Wang
- School of Pharmacy, Changzhou University, No. 21 Middle Gehu Road, Changzhou 213164, PR China.
| | - Jiaxing Zhang
- School of Pharmacy, Changzhou University, No. 21 Middle Gehu Road, Changzhou 213164, PR China
| | - Yang Pei
- Chinese Cultural Teaching Centre, Xi'an Jiaotong-Liverpool University, 111 Ren'ai Road, Suzhou 215123, PR China
| | - Chengqi Li
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215123, PR China
| | - Yulin Li
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215123, PR China
| | - Shaoqing Chen
- Department of Radiology, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou 213004, PR China.
| | - Ziyu Wang
- State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou 215123, PR China.
| |
Collapse
|
2
|
Chen MM, Gao H, Ge ZB, Zhao FJ, Xu JJ, Wang P. Ultrasensitive Electrochemiluminescence Sensor Utilizing Aggregation-Induced Emission Active Probe for Accurate Arsenite Quantification in Rice Grains. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:2826-2833. [PMID: 38282384 DOI: 10.1021/acs.jafc.3c08389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2024]
Abstract
Arsenic (As) constitutes a substantial threat to global ecosystems and public health. An accurate quantification of inorganic arsenite (As(III)) in rice grains is crucial for ensuring food safety and human well-being. Herein, we constructed an electrochemiluminescence (ECL) biosensor utilizing aggregation-induced emission (AIE) active Pdots for the sensitive detection of As(III) in rice. We synthesized tetraphenylethylene-based AIE-active Pdots, exhibiting stable and highly efficient ECL emission in their aggregated states. Owing to the overlap of spectra, we employed an electrochemiluminescence resonance energy transfer (ECL-RET) system, with the Pdots as the donor and black hole quencher (BHQ) as the acceptor. Upon the introduction of As(III), the conformational changes of As(III)-specific aptamer could trigger the detachment of BHQ-labeled DNA aptamer from the electrode surface, leading to the recovery of the ECL signal. The target-induced "signal-on" bioassay enabled the sensitive and specific detection of As(III) with a linear range of 10 pM to 500 nM, with an ultralow limit of detection (LOD) of 5.8 pM/0.4 ppt. These values significantly surpass those of existing sensors designed for As(III) quantification in rice. Furthermore, by employing amylase hydrolysis for efficient extraction, we successfully applied our sensor to measure As(III) in actual rice samples sourced from diverse regions of China. The results obtained using our sensor were in close agreement with those derived from the reference method of HPLC-ICP-MS. This study not only presents a sensitive and reliable method for detecting arsenite but also underscores its potential applications in enhancing food safety, agriculture practices, and environmental monitoring.
Collapse
Affiliation(s)
- Ming-Ming Chen
- Centre for Agriculture and Health, Academy for Advanced Interdisciplinary Studies, Nanjing Agricultural University, Nanjing 210095, China
| | - Hang Gao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Zhan-Biao Ge
- Jiangsu Collaborative Innovation Center for Solid Organic Waste Resource Utilization, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095, China
| | - Fang-Jie Zhao
- Jiangsu Collaborative Innovation Center for Solid Organic Waste Resource Utilization, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095, China
| | - Jing-Juan Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Peng Wang
- Centre for Agriculture and Health, Academy for Advanced Interdisciplinary Studies, Nanjing Agricultural University, Nanjing 210095, China
- Jiangsu Collaborative Innovation Center for Solid Organic Waste Resource Utilization, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095, China
| |
Collapse
|
3
|
Dong M, Jiang D, Cao Q, Wang W, Shiigi H, Chen Z. A metal-organic framework regulated graphdiyne-based electrochemiluminescence sensor with a electrocatalytic self-acceleration effect for the detection of di-(2-ethylhexyl) phthalate. Analyst 2023; 148:4470-4478. [PMID: 37574902 DOI: 10.1039/d3an00954h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
In this work, a super-sensitive electrochemiluminescence (ECL) aptamer sensor was constructed using a multiple signal amplification strategy to realize ultra-sensitive detection of di-(2-ethylhexyl) phthalate (DEHP). The incorporation of a highly efficient electrocatalytic metal-organic framework (NH2-Zr-MOF) and graphdiyne (GDY) composite has significantly enhanced the overall electrochemically active surface area, facilitating electron transfer during the entire electrochemical reaction process, and the large number of pores in graphdiyne and NH2-Zr-MOF limited a series of redox reactions within a certain range. This resulted in the generation of a greater number of SO4˙- radicals, thereby boosting the ECL intensity of the GDY in the K2S2O8 system. To increase the performance of the sensor even further, sodium ascorbate (NaAsc) as an accelerator was added to the co-reactant system. Additionally, nitrogen micro-nano bubbles with higher stability and stronger mass transfer have been introduced into the ECL system for the first time. Based on these, the aptamer as the recognition element realized the ultra-sensitive detection of DEHP in the linear range of 1.0 × 10-12 to 1.0 × 10-4 mg mL-1 with the limit of detection (LOD) of 2.43 × 10-13 mg mL-1. In summary, we have utilized the electrocatalytic activity of the porous MOF and the reducing capability of sodium ascorbate to enhance the ECL emission of GDY, which has been successfully applied to the detection of DEHP in water samples.
Collapse
Affiliation(s)
- Meihua Dong
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China.
| | - Ding Jiang
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China.
- Advanced Catalysis and Green Manufacturing Collaborative Innovation Center, Changzhou University, Changzhou 213164, China
| | - Qianying Cao
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China.
| | - Wenchang Wang
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China.
- Advanced Catalysis and Green Manufacturing Collaborative Innovation Center, Changzhou University, Changzhou 213164, China
- Analysis and Testing Center, NERC Biomass of Changzhou University, China
| | - Hiroshi Shiigi
- Osaka Metropolitan University, Department of Applied Chemistry, Naka Ku, 1-2 Gakuen, Sakai, Osaka 5998570, Japan
| | - Zhidong Chen
- Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China.
- Advanced Catalysis and Green Manufacturing Collaborative Innovation Center, Changzhou University, Changzhou 213164, China
| |
Collapse
|