1
|
Han HC, Sultan S, Xiang M. The effects of axial twisting and material non-symmetry on arterial bent buckling. J Biomech 2023; 157:111735. [PMID: 37499429 DOI: 10.1016/j.jbiomech.2023.111735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 06/25/2023] [Accepted: 07/18/2023] [Indexed: 07/29/2023]
Abstract
Artery buckling occurs due to hypertensive lumen pressure or reduced axial tension and other pathological conditions. Since arteries in vivo often experience axial twisting and the collagen fiber alignment in the arterial wall may become nonsymmetric, it is imperative to know how axial twisting and nonsymmetric collagen alignment would affect the buckling behavior of arteries. To this end, the objective of this study was to determine the effect of axial twisting and nonsymmetric collagen fiber distribution on the critical pressure of arterial bent buckling. The buckling model analysis was generalized to incorporate an axial twist angle and nonsymmetric fiber alignment. The effect of axial twisting on the critical pressure was simulated and experimentally tested in a group of porcine carotid arteries. Our results showed that axial twisting tends to reduce the critical pressure depending on the axial stretch ratio and twist angle. In addition, nonsymmetric fiber alignment reduces the critical pressure. Experimental results confirmed that a twist angle of 90° reduces the critical pressure significantly (p < 0.05). It was concluded that axial twisting and non-axisymmetric collagen fibers distribution could make arteries prone to bent buckling. These results enrich our understanding of artery buckling and vessel tortuosity. The model analysis and results could also be applicable to other fiber reinforced tubes under lumen pressure and axial twisting.
Collapse
Affiliation(s)
- Hai-Chao Han
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, United States.
| | - Sarah Sultan
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, United States
| | - Michael Xiang
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, United States
| |
Collapse
|
2
|
Han HC. Effects of material non-symmetry on the mechanical behavior of arterial wall. J Mech Behav Biomed Mater 2022; 129:105157. [DOI: 10.1016/j.jmbbm.2022.105157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 01/17/2022] [Accepted: 02/27/2022] [Indexed: 12/21/2022]
|
3
|
Seddighi Y, Han HC. Buckling of Arteries With Noncircular Cross Sections: Theory and Finite Element Simulations. Front Physiol 2021; 12:712636. [PMID: 34483964 PMCID: PMC8414815 DOI: 10.3389/fphys.2021.712636] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 07/01/2021] [Indexed: 11/17/2022] Open
Abstract
The stability of blood vessels is essential for maintaining the normal arterial function, and loss of stability may result in blood vessel tortuosity. The previous theoretical models of artery buckling were developed for circular vessel models, but arteries often demonstrate geometric variations such as elliptic and eccentric cross-sections. The objective of this study was to establish the theoretical foundation for noncircular blood vessel bent (i.e., lateral) buckling and simulate the buckling behavior of arteries with elliptic and eccentric cross-sections using finite element analysis. A generalized buckling equation for noncircular vessels was derived and finite element analysis was conducted to simulate the artery buckling behavior under lumen pressure and axial tension. The arterial wall was modeled as a thick-walled cylinder with hyper-elastic anisotropic and homogeneous material. The results demonstrated that oval or eccentric cross-section increases the critical buckling pressure of arteries and having both ovalness and eccentricity would further enhance the effect. We conclude that variations of the cross-sectional shape affect the critical pressure of arteries. These results improve the understanding of the mechanical stability of arteries.
Collapse
Affiliation(s)
- Yasamin Seddighi
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, United States
| | - Hai-Chao Han
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, United States
| |
Collapse
|
4
|
Thirugnanasambandam M, Canchi T, Piskin S, Karmonik C, Kung E, Menon PG, Avril S, Finol EA. Design, Development, and Temporal Evaluation of a Magnetic Resonance Imaging-Compatible In Vitro Circulation Model Using a Compliant Abdominal Aortic Aneurysm Phantom. J Biomech Eng 2021; 143:051004. [PMID: 33493273 PMCID: PMC8086180 DOI: 10.1115/1.4049894] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 01/05/2021] [Indexed: 11/08/2022]
Abstract
Biomechanical characterization of abdominal aortic aneurysms (AAAs) has become commonplace in rupture risk assessment studies. However, its translation to the clinic has been greatly limited due to the complexity associated with its tools and their implementation. The unattainability of patient-specific tissue properties leads to the use of generalized population-averaged material models in finite element analyses, which adds a degree of uncertainty to the wall mechanics quantification. In addition, computational fluid dynamics modeling of AAA typically lacks the patient-specific inflow and outflow boundary conditions that should be obtained by nonstandard of care clinical imaging. An alternative approach for analyzing AAA flow and sac volume changes is to conduct in vitro experiments in a controlled laboratory environment. In this study, we designed, built, and characterized quantitatively a benchtop flow loop using a deformable AAA silicone phantom representative of a patient-specific geometry. The impedance modules, which are essential components of the flow loop, were fine-tuned to ensure typical intraluminal pressure conditions within the AAA sac. The phantom was imaged with a magnetic resonance imaging (MRI) scanner to acquire time-resolved images of the moving wall and the velocity field inside the sac. Temporal AAA sac volume changes lead to a corresponding variation in compliance throughout the cardiac cycle. The primary outcome of this work was the design optimization of the impedance elements, the quantitative characterization of the resistive and capacitive attributes of a compliant AAA phantom, and the exemplary use of MRI for flow visualization and quantification of the deformed AAA geometry.
Collapse
Affiliation(s)
- Mirunalini Thirugnanasambandam
- University of Texas at San Antonio, UTSA/UTHSCSA Joint Graduate Program in Biomedical Engineering, San Antonio, TX 78249
| | - Tejas Canchi
- Department of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798
| | - Senol Piskin
- Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249; Department of Mechanical Engineering, Istinye University, Istanbul 34010, Turkey
| | | | - Ethan Kung
- Department of Mechanical Engineering, Clemson UniversityClemson, SC 29634
| | - Prahlad G. Menon
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15260
| | - Stephane Avril
- Ecole Nationale Supérieure des Mines, Center for Biomedical and Healthcare Engineering, St-Etienne 75006, France
| | - Ender A. Finol
- University of Texas at San Antonio, UTSA/UTHSCSA Joint Graduate Program in Biomedical Engineering, San Antonio, TX 78249; Department of Mechanical Engineering, University of Texas at San Antonio, Room EB 3.04.08 One UTSA Circle, San Antonio, TX 78249
| |
Collapse
|
5
|
Abstract
Vascular tortuosity may impede blood flow, occlude the lumen, and ultimately lead to ischemia or even infarction. Mechanical loads like blood pressure, axial force, and also torsion are key factors participating in this complex mechanobiological process. The available studies on arterial torsion instability followed computational or experimental approaches, yet single available theoretical study had modeled the artery as isotropic linear elastic. This paper aim is to validate a theoretical model of arterial torsion instability against experimental data. The artery is modeled as a single-layered, nonlinear, hyperelastic, anisotropic solid, with parameters calibrated from experiment. Linear bifurcation analysis is then performed to predict experimentally measured stability margins. Uncertainties in geometrical parameters and in measured mechanical response were considered. Also, the type of rate (incremental) boundary conditions (RBCs) impact on the results was examined (e.g., dead load, fluid pressure). The predicted critical torque and twist angle followed the experimentally measured trends. The closest prediction errors in the critical torque and twist rate were 22% and 67%, respectively. Using the different RBCs incurred differences of up to 50% difference within the model predictions. The present results suggest that the model may require further improvements. However, it offers an approach that can be used to predict allowable twist levels in surgical procedures (like anastomosis and grafting) and in the design of stents for arteries subjected to high torsion levels (like the femoropopliteal arteries). It may also be instructive in understanding biomechanical processes like arterial tortuosity, kinking, and coiling.
Collapse
Affiliation(s)
- Nir Emuna
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| | - David Durban
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| |
Collapse
|
6
|
Sharzehee M, Fatemifar F, Han HC. Computational simulations of the helical buckling behavior of blood vessels. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2019; 35:e3277. [PMID: 31680465 PMCID: PMC7286361 DOI: 10.1002/cnm.3277] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 08/27/2019] [Accepted: 10/17/2019] [Indexed: 06/10/2023]
Abstract
Tortuous vessels are often observed in vivo and could hinder or even disrupt blood flow to distal organs. Besides genetic and biological factors, the in vivo mechanical loading seems to play a role in the formation of tortuous vessels, but the mechanism for formation of helical vessel shape remains unclear. Accordingly, the aim of this study was to investigate the biomechanical loads that trigger the occurrence of helical buckling in blood vessels using finite element analysis. Porcine carotid arteries were modeled as thick-walled cylindrical tubes using generalized Fung and Holzapfel-Gasser-Ogden constitutive models. Physiological loadings, including axial tension, lumen pressure, and axial torque, were applied. Simulations of various geometric dimensions, different constitutive models and at various levels of axial stretch ratios, lumen pressures, and twist angles were performed to identify the mechanical factors that determine the helical stability. Our results demonstrated that axial torsion can cause wringing (twist buckling) that leads to kinking or helical coiling and even looping and winding. The specific buckling patterns depend on the combination of lumen pressure, axial torque, axial tension, and the dimensions of the vessels. This study elucidates the mechanism of how blood vessels buckle under various mechanical loads and how complex mechanical loads yield helical buckling.
Collapse
Affiliation(s)
- Mohammadali Sharzehee
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, USA
| | - Fatemeh Fatemifar
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, USA
| | - Hai-Chao Han
- Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, USA
- Biomedical Engineering Program, UTSA-UTHSCSA, San Antonio, TX
| |
Collapse
|
7
|
Thirugnanasambandam M, Simionescu DT, Escobar PG, Sprague E, Goins B, Clarke GD, Han HC, Amezcua KL, Adeyinka OR, Goergen CJ, Finol E. The Effect of Pentagalloyl Glucose on the Wall Mechanics and Inflammatory Activity of Rat Abdominal Aortic Aneurysms. J Biomech Eng 2019; 140:2683232. [PMID: 30003259 DOI: 10.1115/1.4040398] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
An abdominal aortic aneurysm (AAA) is a permanent localized expansion of the abdominal aorta with mortality rate of up to 90% after rupture. AAA growth is a process of vascular degeneration accompanied by a reduction in wall strength and an increase in inflammatory activity. It is unclear whether this process can be intervened to attenuate AAA growth, and hence, it is of great clinical interest to develop a technique that can stabilize the AAA. The objective of this work is to develop a protocol for future studies to evaluate the effects of drug-based therapies on the mechanics and inflammation in rodent models of AAA. The scope of the study is limited to the use of pentagalloyl glucose (PGG) for aneurysm treatment in the calcium chloride rat AAA model. Peak wall stress (PWS) and matrix metalloproteinase (MMP) activity, which are the biomechanical and biological markers of AAA growth and rupture, were evaluated over 4 weeks in untreated and treated (with PGG) groups. The AAA specimens were mechanically characterized by planar biaxial tensile testing and the data fitted to a five-parameter nonlinear, hyperelastic, anisotropic Holzapfel–Gasser–Ogden (HGO) material model, which was used to perform finite element analysis (FEA) to evaluate PWS. Our results demonstrated that there was a reduction in PWS between pre- and post-AAA induction FEA models in the treatment group compared to the untreated group using either animal-specific or average material properties. However, this reduction was not statistically significant. Conversely, there was a statistically significant reduction in MMP-activated fluorescent signal between pre- and post-AAA induction models in the treated group compared to the untreated group. Therefore, the primary contribution of this work is the quantification of the stabilizing effects of PGG using biomechanical and biological markers of AAA, thus indicating that PGG could be part of a new clinical treatment strategy that will require further investigation.
Collapse
Affiliation(s)
| | | | - Patricia G. Escobar
- Department of Medicine, University of Texas Health at San Antonio, San Antonio, TX 78229
| | - Eugene Sprague
- UTSA/UTHSA Joint Graduate Program in Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249; Department of Medicine, University of Texas Health at San Antonio, San Antonio, TX 78229
| | - Beth Goins
- Department of Radiology, University of Texas Health at San Antonio, San Antonio, TX 78229
| | - Geoffrey D. Clarke
- Department of Radiology, University of Texas Health at San Antonio, San Antonio, TX 78229
| | - Hai-Chao Han
- UTSA/UTHSA Joint Graduate Program in Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249; Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249
| | - Krysta L. Amezcua
- UTSA/UTHSA Joint Graduate Program in Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249
| | - Oluwaseun R. Adeyinka
- UTSA/UTHSA Joint Graduate Program in Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249
| | - Craig J. Goergen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907
| | - Ender Finol
- UTSA/UTHSA Joint Graduate Program in Biomedical Engineering, University of Texas at San Antonio, San Antonio, TX 78249; Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249 e-mail:
| |
Collapse
|
8
|
Emuna N, Durban D. Instability of Incompatible Bilayered Soft Tissues and the Role of Interface Conditions. J Biomech Eng 2019; 141:2732258. [DOI: 10.1115/1.4043560] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Indexed: 11/08/2022]
Abstract
Mechanical stability analysis is instructive in explaining biological processes like morphogenesis, organogenesis, and pathogenesis of soft tissues. Consideration of the layered, residually stressed structure of tissues, requires accounting for the joint effects of interface conditions and layer incompatibility. This paper is concerned with the influence of imposed rate (incremental) interface conditions (RICs) on critical loads in soft tissues, within the context of linear bifurcation analysis. Aiming at simplicity, we analyze a model of bilayered isotropic hyperelastic (neo-Hookean) spherical shells with residual stresses generated by “shrink-fitting” two perfectly bonded layers with radial interfacial incompatibility. This setting allows a comparison between available, seemingly equivalent, interface conditions commonly used in the literature of layered media stability. We analytically determine the circumstances under which the interface conditions are equivalent or not, and numerically demonstrate significant differences between interface conditions with increasing level of layer incompatibility. Differences of more than tenfold in buckling and 30% in inflation instability critical loads are recorded using the different RICs. Contrasting instability characteristics are also revealed using the different RICs in the presence of incompatibility: inflation instability can occur before pressure maximum, and spontaneous instability may be excluded for thin shells. These findings are relevant to the growing body of stability studies of layered and residually stressed tissues. The impact of interface conditions on critical thresholds is significant in studies that use concepts of instability to draw conclusions about the normal development and the pathologies of tissues like arteries, esophagus, airways, and the brain.
Collapse
Affiliation(s)
- Nir Emuna
- Faculty of Aerospace Engineering, Technion—Israel Institute of Technology, Haifa 32000, Israel e-mail:
| | - David Durban
- Faculty of Aerospace Engineering, Technion—Israel Institute of Technology, Haifa 32000, Israel e-mail:
| |
Collapse
|
9
|
|
10
|
Zamani M, Khafaji M, Naji M, Vossoughi M, Alemzadeh I, Haghighipour N. A Biomimetic Heparinized Composite Silk-Based Vascular Scaffold with sustained Antithrombogenicity. Sci Rep 2017; 7:4455. [PMID: 28667291 PMCID: PMC5493666 DOI: 10.1038/s41598-017-04510-1] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 05/17/2017] [Indexed: 12/03/2022] Open
Abstract
Autologous grafts, as the gold standard for vascular bypass procedures, associated with several problems that limit their usability, so tissue engineered vessels have been the subject of an increasing number of works. Nevertheless, gathering all of the desired characteristics of vascular scaffolds in the same construct has been a big challenge for scientists. Herein, a composite silk-based vascular scaffold (CSVS) was proposed to consider all the mechanical, structural and biological requirements of a small-diameter vascular scaffold. The scaffold’s lumen composed of braided silk fiber-reinforced silk fibroin (SF) sponge covalently heparinized (H-CSVS) using Hydroxy-Iron Complexes (HICs) as linkers. The highly porous SF external layer with pores above 60 μm was obtained by lyophilization. Silk fibers were fully embedded in scaffold’s wall with no delamination. The H-CSVS exhibited much higher burst pressure and suture retention strength than native vessels while comparable elastic modulus and compliance. H-CSVSs presented milder hemolysis in vitro and significant calcification resistance in subcutaneous implantation compared to non-heparinized ones. The in vitro antithrombogenic activity was sustained for over 12 weeks. The cytocompatibility was approved using endothelial cells (ECs) and vascular smooth muscle cells (SMCs) in vitro. Therefore, H-CSVS demonstrates a promising candidate for engineering of small-diameter vessels.
Collapse
Affiliation(s)
- Masoud Zamani
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Mona Khafaji
- Institute for Nano-science and Nano-technology, Sharif University of Technology, Tehran, Iran
| | - Mohammad Naji
- Department of Anatomy, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Manouchehr Vossoughi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran. .,Institute for Nano-science and Nano-technology, Sharif University of Technology, Tehran, Iran.
| | - Iran Alemzadeh
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | | |
Collapse
|
11
|
Garcia JR, Sanyal A, Fatemifar F, Mottahedi M, Han HC. Twist buckling of veins under torsional loading. J Biomech 2017; 58:123-130. [PMID: 28526174 DOI: 10.1016/j.jbiomech.2017.04.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 03/31/2017] [Accepted: 04/24/2017] [Indexed: 10/19/2022]
Abstract
Veins are often subjected to torsion and twisted veins can hinder and disrupt normal blood flow but their mechanical behavior under torsion is poorly understood. The objective of this study was to investigate the twist deformation and buckling behavior of veins under torsion. Twist buckling tests were performed on porcine internal jugular veins (IJVs) and human great saphenous veins (GSVs) at various axial stretch ratio and lumen pressure conditions to determine their critical buckling torques and critical buckling twist angles. The mechanical behavior under torsion was characterized using a two-fiber strain energy density function and the buckling behavior was then simulated using finite element analysis. Our results demonstrated that twist buckling occurred in all veins under excessive torque characterized by a sudden kink formation. The critical buckling torque increased significantly with increasing lumen pressure for both porcine IJV and human GSV. But lumen pressure and axial stretch had little effect on the critical twist angle. The human GSVs are stiffer than the porcine IJVs. Finite element simulations captured the buckling behavior for individual veins under simultaneous extension, inflation, and torsion with strong correlation between predicted critical buckling torques and experimental data (R2=0.96). We conclude that veins can buckle under torsion loading and the lumen pressure significantly affects the critical buckling torque. These results improve our understanding of vein twist behavior and help identify key factors associated in the formation of twisted veins.
Collapse
Affiliation(s)
- Justin R Garcia
- Department of Mechanical Engineering, University of Texas at San Antonio, USA; Biomedical Engineering Program, UTSA-UTHSCSA, USA
| | - Arnav Sanyal
- Department of Mechanical Engineering, University of Texas at San Antonio, USA
| | - Fatemeh Fatemifar
- Department of Mechanical Engineering, University of Texas at San Antonio, USA
| | - Mohammad Mottahedi
- Department of Mechanical Engineering, University of Texas at San Antonio, USA
| | - Hai-Chao Han
- Department of Mechanical Engineering, University of Texas at San Antonio, USA; Biomedical Engineering Program, UTSA-UTHSCSA, USA; Institute of Mechanobiology & Medical Engineering, Shanghai Jiaotong University, China.
| |
Collapse
|
12
|
Han HC, Liu Q, Jiang ZL. Mechanical behavior and wall remodeling of blood vessels under axial twist. YI YONG SHENG WU LI XUE 2016; 31:319-326. [PMID: 28529430 PMCID: PMC5437748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Blood vessels are often subjected to axial torsion (or twist) due to body movement or surgery. However, there are few studies on blood vessel under twist. This review first summarizes the clinical observation on the twist of blood vessels and then presents what we know about the mechanical behaviors of blood vessel under twist, including the constitutive models. The state of art researches on the remodeling of blood vessels under twist via ex vivo organ culture, in vivo animal experiments, and mathematical model simulations are further discussed. It is our hope that this review will draw attention for further in-depth studies on the behavior and remodeling of blood vessels under twist.
Collapse
Affiliation(s)
- Hai-Chao Han
- Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
- Institute of Mechanobiology & Medical Engineering, School of Life Sciences & Biotechnology, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Qin Liu
- Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
| | - Zong-Lai Jiang
- Institute of Mechanobiology & Medical Engineering, School of Life Sciences & Biotechnology, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|