Jourdan A, Vegleur A, Bodner J, Rousset P, Passot G, Ruyet AL. A combined experimental and numerical approach to evaluate hernia mesh biomechanical stability in situ. Med Eng Phys 2025; 135:104271. [PMID: 39922651 DOI: 10.1016/j.medengphy.2024.104271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 10/14/2024] [Accepted: 12/01/2024] [Indexed: 02/10/2025]
Abstract
A ventral hernia involves tissue protrusion through the abdominal wall (AW). It is a common surgical issue with high recurrence rates. Primary stability of hernia meshes is essential to guarantee mesh integration, yet existing meshes often fail to match the AW's complex biomechanics. This study proposes a novel method aiming at understanding post-operative mesh-AW interactions. Three fresh frozen human specimens underwent an open Rives-Stoppa implantation of a synthetic hernia mesh coated with metallic micro-beads. Additional beads were placed into the AW muscle tissue. CT scans were conducted at increasing levels of intra-abdominal pressure to reproduce forced breathing. Beads 3D coordinates were exported from the CT-scans and motion and strain of both the hernia mesh and the AW were calculated. At 30 mmHg, the mesh-muscle motion (or sliding) was 2.3 ± 1.3 mm. Muscle exhibited significantly higher strains (12.9 ± 4.7 %) than the hernia mesh (4.7 ± 1.1 %), most likely due to difference in material properties between the mesh and the AW. A repeatability study was carried out to build confidence in the proposed method. This protocol can bring insights of the hernia mesh use-conditions to improve hernia mesh design requirements and develop safer implants to reduce hernia recurrence.
Collapse
Affiliation(s)
- Arthur Jourdan
- Medtronic, Surgical Operating Unit, General Surgical Technologies - BioTex, Trévoux, France.
| | - Anthony Vegleur
- Medtronic, Surgical Operating Unit, General Surgical Technologies - BioTex, Trévoux, France.
| | - Jeff Bodner
- Medtronic, Corporate Core Technologies, MN, USA.
| | - Pascal Rousset
- Department of Radiology, Hospices Civils de Lyon, Lyon Sud University Hospital, Lyon 1 Claude Bernard University, EMR 3738, Pierre Bénite, France.
| | - Guillaume Passot
- Department of General Surgery, Hospices Civils de Lyon, Lyon Sud University Hospital, Lyon 1 Claude Bernard University, EMR 3738, Pierre Bénite, France.
| | - Anicet Le Ruyet
- Medtronic, Surgical Operating Unit, General Surgical Technologies - BioTex, Trévoux, France.
| |
Collapse
|
2
|
Jinka SK, Janis JE. Clinically Applied Biomechanics of Mesh-reinforced Ventral Hernia Repair: A Practical Review. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2024; 12:e6294. [PMID: 39583784 PMCID: PMC11584225 DOI: 10.1097/gox.0000000000006294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 09/18/2024] [Indexed: 11/26/2024]
Abstract
Background Ventral hernia repair is inherently prone to recurrence. This article is a practical review that summarizes the literature on the biomechanics of ventral hernia repairs to provide clinically applicable, evidence-based recommendations to reduce hernia recurrence. Methods A practical review of all relevant literature in PubMed concerning the mechanics of ventral hernia repairs and the forces involved was conducted in August 2023. Results Of the 598 full-text publications retrieved, 29 satisfied inclusion criteria. Among these, 5 articles included enough numeric data for a quantitative analysis of the ultimate tensile strength of the layers of the abdominal wall. Conclusions The utilization of mesh in ventral hernia repairs is recommended to strengthen weakened abdominal wall tissue. It is essential to primarily close the anterior sheath with a robust mesh-tissue overlap to promote "load-sharing" between the mesh and the abdominal wall. This approach reduces mesh deformity and stress on fixation points, leading to lower hernia recurrence rates. Minimizing mesh fixation (when placed in the retromuscular plane) can reduce postoperative pain and hospital stay without significantly affecting hernia recurrence. Orienting mesh according to abdominal anisotropy is crucial for reducing mesh stiffness, improving healing, and preventing recurrence. Future studies with advanced computer modeling will continue to provide further insights into mesh biomechanics and abdominal wall healing.
Collapse
Affiliation(s)
- Sanjay K.A. Jinka
- From the Department of Plastic Surgery, Wright State University, Dayton, Ohio
| | - Jeffrey E. Janis
- Department of Plastic and Reconstructive Surgery, Ohio State University Wexner Medical Center, Columbus, Ohio
| |
Collapse
|
3
|
Naveed A, Martin ND, Bawazeer M, Jastaniah A, Rezende-Neto JB. Early placement of a non-invasive, pressure-regulated, fascial reapproximation device improves reduction of the fascial gap in open abdomens: a retrospective cohort study. Trauma Surg Acute Care Open 2024; 9:e001529. [PMID: 39411009 PMCID: PMC11474681 DOI: 10.1136/tsaco-2024-001529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Accepted: 09/23/2024] [Indexed: 10/19/2024] Open
Abstract
Background Since current fascial traction methods involve invasive procedures, they are generally employed late in the management of the open abdomen (OA). This study aimed to evaluate early versus late placement of a non-invasive, pressure-regulated device for fascial reapproximation and gap reduction in OA patients. Methods The study included all patients who had the abdominal fascia intentionally left open after damage control operation for trauma and emergency general surgery and were managed with the device in an academic hospital between January 1, 2020, and December 31, 2023. Time of device placement in relation to the end of index laparotomy was defined as early (≤24 hours) versus late (>24 hours). Time-related mid-incisional width reduction of the fascial gap and fascial closure were assessed using descriptive and linear regression analysis. Results There was a significantly higher percent reduction in the fascial gap at the midpoint of the laparotomies in the early (≤24 hours) AbClo placement group compared with the late (>24 hours) AbClo placement group, respectively, median 76% versus 43%, p<0.001. Linear regression adjusting for body mass index and the number of takebacks indicated that fascial approximation was 22% higher for early placement (β=0.22; CI 0.12, 0.33, p<0.001). Primary myofascial closure rate with early (≤24 hours) application of the device was 98% versus 85% with late application. Conclusion Early non-invasive application of the device (≤24 hours) after the initial laparotomy resulted in greater reduction of the fascial gap and higher primary fascial closure rate compared with late placement (>24 hours). Early non-invasive intervention could prevent abdominal wall myofascial retraction in OA patients. Level of evidence IV.
Collapse
Affiliation(s)
- Asad Naveed
- Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Niels D Martin
- Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | - Atif Jastaniah
- Department of Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Joao B Rezende-Neto
- Department of Surgery, Division of General Surgery St. Michael's Hospital, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
4
|
Spadoni S, Todros S, Pavan PG. Numerical modeling of the abdominal wall biomechanics and experimental analysis for model validation. Front Bioeng Biotechnol 2024; 12:1472509. [PMID: 39398644 PMCID: PMC11466767 DOI: 10.3389/fbioe.2024.1472509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Accepted: 09/17/2024] [Indexed: 10/15/2024] Open
Abstract
The evaluation of the biomechanics of the abdominal wall is particularly important to understand the onset of pathological conditions related to weakening and injury of the abdominal muscles. A better understanding of the biomechanics of the abdominal wall could be a breakthrough in the development of new therapeutic approaches. For this purpose, several studies in the literature propose finite element models of the human abdomen, based on the geometry of the abdominal wall from medical images and on constitutive formulations describing the mechanical behavior of fascial and muscular tissues. The biomechanics of the abdominal wall depends on the passive mechanical properties of fascial and muscle tissue, on the activation of abdominal muscles, and on the variable intra-abdominal pressure. To assess the quantitative contribution of these features to the development and validation of reliable numerical models, experimental data are fundamental. This work presents a review of the state of the art of numerical models developed to investigate abdominal wall biomechanics. Different experimental techniques, which can provide data for model validation, are also presented. These include electromyography, ultrasound imaging, intraabdominal pressure measurements, abdominal surface deformation, and stiffness/compliance measurements.
Collapse
Affiliation(s)
- Silvia Spadoni
- Department of Industrial Engineering, University of Padova, Padova, Italy
| | - Silvia Todros
- Department of Industrial Engineering, University of Padova, Padova, Italy
| | - Piero G. Pavan
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Fondazione Istituto di Ricerca Pediatrica Città della Speranza, Padova, Italy
| |
Collapse
|
5
|
Yuan J, Sun B, Ma W, Cai C, Huang Z, Zhou P, Yi L, Liu L, Chen S. Orthogonally woven 3D nanofiber scaffolds promote rapid soft tissue regeneration by enhancing bidirectional cell migration. Bioact Mater 2024; 39:582-594. [PMID: 38883316 PMCID: PMC11179174 DOI: 10.1016/j.bioactmat.2024.04.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 04/17/2024] [Accepted: 04/22/2024] [Indexed: 06/18/2024] Open
Abstract
Repairing large-area soft tissue defects caused by traumas is a major surgical challenge. Developing multifunctional scaffolds with suitable scalability and favorable cellular response is crucial for soft tissue regeneration. In this study, we developed an orthogonally woven three-dimensional (3D) nanofiber scaffold combining electrospinning, weaving, and modified gas-foaming technology. The developed orthogonally woven 3D nanofiber scaffold had a modular design and controlled fiber alignment. In vitro, the orthogonally woven 3D nanofiber scaffold exhibited adjustable mechanical properties, good cell compatibility, and easy drug loading. In vivo, for one thing, the implantation of an orthogonally woven 3D nanofiber scaffold in a full abdominal wall defect model demonstrated that extensive granulation tissue formation with enough mechanical strength could promote recovery of abdominal wall defects while reducing intestinal adhesion. Another result of diabetic wound repair experiments suggested that orthogonally woven 3D nanofiber scaffolds had a higher wound healing ratio, granulation tissue formation, collagen deposition, and re-epithelialization. Taken together, this novel orthogonally woven 3D nanofiber scaffold may provide a promising and effective approach for optimal soft tissue regeneration.
Collapse
Affiliation(s)
- Jiayi Yuan
- School of Pharmacy, Jiangsu Ocean University, Lianyungang, 222005, China
- Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325001, China
| | - Bingbing Sun
- Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325001, China
- Department of Critical Care Medicine, The Air Force Characteristic Medical Center, Air Force Medical University, Beijing, 100000, China
| | - Weixing Ma
- School of Pharmacy, Jiangsu Ocean University, Lianyungang, 222005, China
| | - Chao Cai
- Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325001, China
| | - Zhenzhen Huang
- Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325001, China
| | - Peiyi Zhou
- Chongqing Health Center for Women and Children, Chongqing Obstetric and Gynecologic Hospital, Chongqing, China
| | - Lei Yi
- Department of Burn, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Lubin Liu
- Chongqing Health Center for Women and Children, Chongqing Obstetric and Gynecologic Hospital, Chongqing, China
| | - Shixuan Chen
- Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, 325001, China
| |
Collapse
|
6
|
Troka M, Szepietowska K, Lubowiecka I. Self-organising maps in the analysis of strains of human abdominal wall to identify areas of similar mechanical behaviour. J Mech Behav Biomed Mater 2024; 156:106578. [PMID: 38781775 DOI: 10.1016/j.jmbbm.2024.106578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 03/05/2024] [Accepted: 05/08/2024] [Indexed: 05/25/2024]
Abstract
The study refers to the application of a type of artificial neural network called the Self-Organising Map (SOM) for the identification of areas of the human abdominal wall that behave in a similar mechanical way. The research is based on data acquired during in vivo tests using the digital image correlation technique (DIC). The mechanical behaviour of the human abdominal wall is analysed during changing intra-abdominal pressure. SOM allow to study simultaneously three variables in four time/load steps. The variables refer to the principal strains and their directions. SOM classifies all the abdominal surface data points into clusters that behave similarly in accordance with the 12 variables. The analysis of the clusters provides a better insight into abdominal wall deformation and its evolution under pressure than when observing a single mechanical variable. The presented results may provide a better understanding of the mechanics of the living human abdominal wall. It might be particularly useful when selecting proper implants as well as for the design of surgical meshes for the treatment of abdominal hernias, which would be mechanically compatible with identified regions of the human anterior abdominal wall, and possibly open the way for patient-specific solutions.
Collapse
Affiliation(s)
- Mateusz Troka
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Katarzyna Szepietowska
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Izabela Lubowiecka
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland.
| |
Collapse
|
7
|
Gueroult P, Joppin V, Chaumoitre K, Di Bisceglie M, Masson C, Bege T. Linea alba 3D morphometric variability by CT scan exploration. Hernia 2024; 28:485-494. [PMID: 38177404 DOI: 10.1007/s10029-023-02939-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 11/26/2023] [Indexed: 01/06/2024]
Abstract
PURPOSE The width of the Linea alba, which is often gauged by inter-rectus distance, is a key risk factor for incisional hernia and recurrence. Previous studies provided limited descriptions with no consideration for width, location variability, or curvature. We aimed to offer a comprehensive 3D anatomical analysis of the Linea alba, emphasizing its variations across diverse demographics. METHODS Using open source software, 2D sagittal plane and 3D reconstructions were performed on 117 patients' CT scans. Linea alba length, curvature assessed by the sagitta (the longest perpendicular segment between xipho-pubic line and the Linea alba), and continuous width along the height were measured. RESULTS The Linea alba had a rhombus shape, with a maximum width at the umbilicus of 4.4 ± 1.9 cm and a larger width above the umbilicus than below. Its length was 37.5 ± 3.6 cm, which increased with body mass index (BMI) (p < 0.001), and was shorter in women (p < 0.001). The sagitta was 2.6 ± 2.2 cm, three times higher in the obese group (p < 0.001), majorated with age (p = 0.009), but was independent of gender (p = 0.212). Linea alba width increased with both age and BMI (p < 0.001-p = 0.002), being notably wider in women halfway between the umbilicus and pubis (p = 0.007). CONCLUSION This study provides an exhaustive 3D description of Linea alba's anatomical variability, presenting new considerations for curvature. This method provides a patient-specific anatomy description of the Linea alba. Further studies are needed to determine whether 3D reconstruction correlates with pathologies, such as hernias and diastasis recti.
Collapse
Affiliation(s)
- P Gueroult
- Laboratoire de Biomécanique Appliquée, Aix Marseille Univ, IFSTTAR UMR T24, Marseille, France.
- Service de chirurgie viscérale et endocrinienne, Angers University Hospital, Rue Larrey, 49933, CEDEX 9, Angers, France.
| | - V Joppin
- Laboratoire de Biomécanique Appliquée, Aix Marseille Univ, IFSTTAR UMR T24, Marseille, France
| | - K Chaumoitre
- Department of Medical Imaging, Aix Marseille Univ, North Hospital, APHM, Marseille, France
- Anthropologie Biologique UMR 7268ADES, Aix Marseille Univ, Marseille, France
| | - M Di Bisceglie
- Department of Medical Imaging, Aix Marseille Univ, North Hospital, APHM, Marseille, France
| | - C Masson
- Laboratoire de Biomécanique Appliquée, Aix Marseille Univ, IFSTTAR UMR T24, Marseille, France
| | - T Bege
- Laboratoire de Biomécanique Appliquée, Aix Marseille Univ, IFSTTAR UMR T24, Marseille, France
- Department of General Surgery, Aix Marseille Univ, North Hospital, APHM, Marseille, France
| |
Collapse
|
8
|
Terrie L, Philips C, Muylle E, Weisrock A, Lecomte-Grosbras P, Thorrez L. Decellularized tissue exhibits large differences of extracellular matrix properties dependent on decellularization method: novel insights from a standardized characterization on skeletal muscle. Biofabrication 2024; 16:025033. [PMID: 38394679 DOI: 10.1088/1758-5090/ad2c99] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 02/23/2024] [Indexed: 02/25/2024]
Abstract
Decellularized matrices are an attractive choice of scaffold in regenerative medicine as they can provide the necessary extracellular matrix (ECM) components, signals and mechanical properties. Various detergent-based protocols have already been proposed for decellularization of skeletal muscle tissue. However, a proper comparison is difficult due to differences in species, muscle origin and sample sizes. Moreover, a thorough evaluation of the remaining acellular matrix is often lacking. We compared an in-house developed decellularization protocol to four previously published methods in a standardized manner. Porcine skeletal muscle samples with uniform thickness were subjected to in-depth histological, ultrastructural, biochemical and biomechanical analysis. In addition, 2D and three-dimensional cytocompatibility experiments were performed. We found that the decellularization methods had a differential effect on the properties of the resulting acellular matrices. Sodium deoxycholate combined with deoxyribonuclease I was not an effective method for decellularizing thick skeletal muscle tissue. Triton X-100 in combination with trypsin, on the other hand, removed nuclear material but not cytoplasmic proteins at low concentrations. Moreover, it led to significant alterations in the biomechanical properties. Finally, sodium dodecyl sulphate (SDS) seemed most promising, resulting in a drastic decrease in DNA content without major effects on the ECM composition and biomechanical properties. Moreover, cell attachment and metabolic activity were also found to be the highest on samples decellularized with SDS. Through a newly proposed standardized analysis, we provide a comprehensive understanding of the impact of different decellularizing agents on the structure and composition of skeletal muscle. Evaluation of nuclear content as well as ECM composition, biomechanical properties and cell growth are important parameters to assess. SDS comes forward as a detergent with the best balance between all measured parameters and holds the most promise for decellularization of skeletal muscle tissue.
Collapse
Affiliation(s)
- Lisanne Terrie
- Tissue Engineering Lab, Department of Development and Regeneration, KU Leuven, Kortrijk, Belgium
| | - Charlot Philips
- Tissue Engineering Lab, Department of Development and Regeneration, KU Leuven, Kortrijk, Belgium
| | - Ewout Muylle
- Tissue Engineering Lab, Department of Development and Regeneration, KU Leuven, Kortrijk, Belgium
| | - Antoine Weisrock
- Tissue Engineering Lab, Department of Development and Regeneration, KU Leuven, Kortrijk, Belgium
- Univ. Lille, CNRS, Centrale Lille, UMR 9013-LaMcube-Laboratoire de Mécanique, Multiphysique, Multi-échelle, Lille, France
| | - Pauline Lecomte-Grosbras
- Univ. Lille, CNRS, Centrale Lille, UMR 9013-LaMcube-Laboratoire de Mécanique, Multiphysique, Multi-échelle, Lille, France
| | - Lieven Thorrez
- Tissue Engineering Lab, Department of Development and Regeneration, KU Leuven, Kortrijk, Belgium
| |
Collapse
|
9
|
Jiao Y, Yang X, Li Y, Wang F, Wang L, Li C. Spider-Silk-like Fiber Mat-Covered Polypropylene Warp-Knitted Hernia Mesh for Inhibition of Fibrosis under Dynamic Environment. Biomacromolecules 2024; 25:1214-1227. [PMID: 38295271 DOI: 10.1021/acs.biomac.3c01181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
Hernia surgery is a widely performed procedure, and the use of a polypropylene mesh is considered the standard approach. However, the mesh often leads to complications, including the development of scar tissue that wraps around the mesh and causes it to shrink. Consequently, there is a need to investigate the relationship between the mesh and scar formation as well as to develop a hernia mesh that can prevent fibrosis. In this study, three different commercial polypropylene hernia meshes were examined to explore the connection between the fabric structure and mechanical properties. In vitro dynamic culture was used to investigate the mechanism by which the mechanical properties of the mesh in a dynamic environment affect cell differentiation. Additionally, electrospinning was employed to create polycaprolactone spider-silk-like fiber mats to achieve mechanical energy dissipation in dynamic conditions. These fiber mats were then combined with the preferred hernia mesh. The results demonstrated that the composite mesh could reduce the activation of fibroblast mechanical signaling pathways and inhibit its differentiation into myofibroblasts in dynamic environments.
Collapse
Affiliation(s)
- Yongjie Jiao
- Key Laboratory of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China
| | - Xiaowei Yang
- Key Laboratory of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China
| | - Yan Li
- Key Laboratory of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China
| | - Fujun Wang
- Key Laboratory of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China
| | - Lu Wang
- Key Laboratory of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China
| | - Chaojing Li
- Key Laboratory of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China
| |
Collapse
|
10
|
Jourdan A, Dhume R, Guérin E, Siegel A, Le Ruyet A, Palmer M. Numerical investigation of a finite element abdominal wall model during breathing and muscular contraction. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107985. [PMID: 38185041 DOI: 10.1016/j.cmpb.2023.107985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 12/04/2023] [Accepted: 12/15/2023] [Indexed: 01/09/2024]
Abstract
BACKGROUND AND OBJECTIVE Ventral hernia repair is faced with high recurrence rates. The personalization of the diagnosis, the surgical approach and the choice of the prosthetic implant seem relevant axes to improve the current results. Numerical models have the potential to allow this patient-specific approach, yet currently existing models lack validation. This work extensively investigated a realistic finite element abdominal wall model including the implementation of muscle activation. METHODS A parametric 3D finite element model composed of bone, muscle and aponeurotic structures was introduced. Hyperelastic anisotropic materials were implemented. Two loading scenarios were simulated: passive inflation of the abdominal cavity to represent, e.g., breathing, and passive inflation followed by muscular activation to simulate other daily activities such as cough. The impact of the inter-individual variability (e.g., BMI, tissue thickness, material properties, intra-abdominal pressure (IAP) and muscle contractility) on the model outputs was studied through a sensitivity analysis. RESULTS The overall model predictions were in good agreement with the experimental data in terms of shape variation, muscles displacements, strains and midline forces. A total of 34 and 41 runs were computed for the passive and active sensitivity analysis respectively. The regression model fits rendered high R-squared in both passive (84.0 ± 6.7 %) and active conditions (82.0 ± 8.3 %). IAP and muscle thickness were the most influential factors for the selected outputs during passive (breathing) activities. Maximum isometric stress, muscle thickness and pre-activation IAP were found to drive the response of the simulations involving muscular contraction. The material properties of the connective tissue were essential contributors to the behaviour of the medial part of the abdominal wall. CONCLUSIONS This work extensively investigated a realistic abdominal wall model and evaluated its robustness using experimental data from literature. Such a model could improve patient-specific simulation for ventral hernia surgical planning, prevention, and repair or implant evaluation. Further investigations will be conducted to evaluate the impact of the surgical technique and the mechanical characteristic of prosthetic meshes on the model outputs.
Collapse
Affiliation(s)
- Arthur Jourdan
- Medtronic, Surgical Operating Unit, General Surgical Technologies, 116 Avenue du Formans, BioTex 01600, Trévoux, France.
| | - Rohit Dhume
- Medtronic, Corporate Core Technologies, MN, USA
| | - Elisabeth Guérin
- Medtronic, Surgical Operating Unit, General Surgical Technologies, 116 Avenue du Formans, BioTex 01600, Trévoux, France
| | - Alice Siegel
- Medtronic, Surgical Operating Unit, General Surgical Technologies, 116 Avenue du Formans, BioTex 01600, Trévoux, France
| | - Anicet Le Ruyet
- Medtronic, Surgical Operating Unit, General Surgical Technologies, 116 Avenue du Formans, BioTex 01600, Trévoux, France
| | - Mark Palmer
- Medtronic, Corporate Core Technologies, MN, USA
| |
Collapse
|
11
|
Jiao Y, Li X, Liu X, Li C, Yang X, Sun X, Wang F, Wang L. Cobweb-Inspired Micro/Nanostructured Scaffolds for Soft Tissue Regeneration with Inhibition Effect of Fibrosis under Dynamic Environment. Adv Healthc Mater 2023; 12:e2300997. [PMID: 37713107 DOI: 10.1002/adhm.202300997] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 08/08/2023] [Indexed: 09/16/2023]
Abstract
In soft tissue repair, fibrosis can lead to repair failure and long-term chronic pain in patients. Excessive mechanical stimulation of fibroblasts is one of the causes of fibrosis during abdominal wall regeneration. Inspired by the cobweb, a polycaprolactone beaded fiber is prepared by electrospinning. The cobweb-inspired structure attenuates the mechanical stimulation of cells under a dynamic environment. Nano-protrusions are introduced into the scaffold for further inhibition of fibrosis by self-induced crystallization. A machine is built for in vitro dynamic culture and rat abdominal subcutaneous embedding experiments are performed to verify the inhibiting effect of fibrosis in a dynamic environment in vivo. Results show that the expression of integrin β1 and α-smooth muscle actin is inhibited by the cobweb-inspired structure under dynamic culture. The results of hematoxylin and eosin and Masson's trichrome indicate that the cobweb-inspired structure has a good inhibitory effect on fibrosis in a dynamic environment in vivo. In general, the cobweb-inspired scaffold with nano-protrusions has a good ability to inhibit fibrosis under both static and dynamic environments. It is believed that the scaffold has promising applications in the field of inhibiting fibrosis caused by mechanical stimulation.
Collapse
Affiliation(s)
- Yongjie Jiao
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Xiaojing Li
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Xingxing Liu
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Chaojing Li
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| | - Xiao Yang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Xuwei Sun
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Fujun Wang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
| | - Lu Wang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology, Donghua University, Shanghai, 201620, China
| |
Collapse
|
12
|
Vergari C, Persohn S, Rohan PY. The effect of breathing on the in vivo mechanical characterization of linea alba by ultrasound shearwave elastography. Comput Biol Med 2023; 167:107637. [PMID: 37897961 DOI: 10.1016/j.compbiomed.2023.107637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/09/2023] [Accepted: 10/24/2023] [Indexed: 10/30/2023]
Abstract
The most common surgical repair of abdominal wall hernia consists in implanting a mesh to reinforce hernia defects during the healing phase. Ultrasound shearwave elastography (SWE) is a promising non-invasive method to estimate soft tissue mechanical properties at bedside through shear wave speed (SWS) measurement. Combined with conventional ultrasonography, it could help the clinician plan surgery. In this work, a novel protocol is proposed to reliably assess the stiffness of the linea alba, and to evaluate the effect of breathing and of inflating the abdomen on SWS. Fifteen healthy adults were included. SWS was measured in the linea alba, in the longitudinal and transverse direction, during several breathing cycle and during active abdominal inflation. SWS during normal breathing was 2.3 [2.0; 2.5] m/s in longitudinal direction and 2.2 [1.9; 2.7] m/s in the transversal. Inflating the abdomen increased SWS both in longitudinal and transversal direction (3.5 [2.8; 5.8] m/s and 5.2 [3.0; 6.0] m/s, respectively). The novel protocol significantly improved the reproducibility relative to the literature (8% in the longitudinal direction and 14% in the transverse one). Breathing had a mild effect on SWS, and accounting for it only marginally improved the reproducibility. This study proved the feasibility of the method, and its potential clinical interest. Further studies on larger cohort should focus on improving our understanding of the relationship between abdominal wall properties and clinical outcomes, but also provide a cartography of the abdominal wall, beyond the linea alba.
Collapse
Affiliation(s)
- Claudio Vergari
- Arts et Métiers Institute of Technology, Institut de Biomécanique Humaine Georges Charpak, Université Sorbonne Paris Nord, Paris, France.
| | - Sylvain Persohn
- Arts et Métiers Institute of Technology, Institut de Biomécanique Humaine Georges Charpak, Université Sorbonne Paris Nord, Paris, France
| | - Pierre-Yves Rohan
- Arts et Métiers Institute of Technology, Institut de Biomécanique Humaine Georges Charpak, Université Sorbonne Paris Nord, Paris, France
| |
Collapse
|
13
|
Szepietowska K, Troka M, Lichodziejewska-Niemierko M, Chmielewski M, Lubowiecka I. Full-field in vivo experimental study of the strains of a breathing human abdominal wall with intra-abdominal pressure variation. J Mech Behav Biomed Mater 2023; 147:106148. [PMID: 37797556 DOI: 10.1016/j.jmbbm.2023.106148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 09/13/2023] [Accepted: 09/23/2023] [Indexed: 10/07/2023]
Abstract
The presented study aims to assess the mechanical behaviour of the anterior abdominal wall based on an in vivo experiment on humans. Full-field measurement of abdominal wall displacement during changes of intra-abdominal pressure is performed using a digital image correlation (DIC) system. Continuous measurement in time enables the observation of changes in the strain field during breathing. The understanding of the mechanical behaviour of a living human abdominal wall is important for the proper design of surgical meshes used for ventral hernia repair, which was also a motivation for the research presented below. The research refers to the strain field of a loaded abdominal wall and presents the evolution of principal strains and their directions in the case of 12 subjects, 8 male and 4 female. Peritoneal dialysis procedure allows for the measurement of intra-abdominal pressure after fluid introduction. High variability among patients is observed, also in terms of principal strain direction. Subjects exhibit intra-abdominal pressure of values from 11 to 21 cmH2O. However, the strain values are not strongly correlated with the pressure value, indicating variability of material properties.
Collapse
Affiliation(s)
- Katarzyna Szepietowska
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | - Mateusz Troka
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland
| | | | - Michał Chmielewski
- Department of Nephrology, Transplantology and Internal Medicine, Medical University of Gdańsk, Gdańsk, Poland
| | - Izabela Lubowiecka
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gdańsk, Poland.
| |
Collapse
|
14
|
Whitehead-Clarke T, Brown C, Ail G, Mudera V, Smith C, Kureshi A. Characterisation of human posterior rectus sheath reveals mechanical and structural anisotropy. Clin Biomech (Bristol, Avon) 2023; 106:105989. [PMID: 37244136 DOI: 10.1016/j.clinbiomech.2023.105989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 05/01/2023] [Accepted: 05/10/2023] [Indexed: 05/29/2023]
Abstract
BACKGROUND Our work aims to investigate the mechanical properties of the human posterior rectus sheath in terms of its ultimate tensile stress, stiffness, thickness and anisotropy. It also aims to assess the collagen fibre organisation of the posterior rectus sheath using Second-Harmonic Generation microscopy. METHODS For mechanical analysis, twenty-five fresh-frozen samples of posterior rectus sheath were taken from six different cadaveric donors. They underwent uniaxial tensile stress testing until rupture either in the transverse (n = 15) or longitudinal (n = 10) plane. The thickness of each sample was also recorded using digital callipers. On a separate occasion, ten posterior rectus sheath samples and three anterior rectus sheath samples underwent microscopy and photography to assess collagen fibre organisation. FINDINGS samples had a mean ultimate tensile stress of 7.7 MPa (SD 4.9) in the transverse plane and 1.2 MPa (SD 0.8) in the longitudinal plane (P < 0.01). The same samples had a mean Youngs modulus of 11.1 MPa (SD 5.0) in the transverse plane and 1.7 MPa (SD 1.3) in the longitudinal plane (P < 0.01). The mean thickness of the posterior rectus sheath was 0.51 mm (SD 0.13). Transversely aligned collagen fibres could be identified within the posterior sheath tissue using Second-Harmonic Generation microscopy. INTERPRETATION The posterior rectus sheath displays mechanical and structural anisotropy with greater tensile stress and stiffness in the transverse plane compared to the longitudinal plane. The mean thickness of this layer is around 0.51 mm - consistent with other studies. The tissue is constructed of transversely aligned collagen fibres that are visible using Second-Harmonic Generation microscopy.
Collapse
Affiliation(s)
- Thomas Whitehead-Clarke
- Centre for 3D Models of Health and Disease, Division of Surgery and Interventional Science, University College London, UK.
| | | | - Geetika Ail
- Department of Anatomy, Brighton and Sussex Medical School, UK
| | - Vivek Mudera
- Division of Surgery and Interventional Science, University College London, UK
| | - Claire Smith
- Department of Anatomy, Brighton and Sussex Medical School, UK
| | - Alvena Kureshi
- Division of Surgery and Interventional Science, University College London, UK
| |
Collapse
|
15
|
Olmos-Juste R, Olza S, Gabilondo N, Eceiza A. Tailor-Made 3D Printed Meshes of Alginate-Waterborne Polyurethane as Suitable Implants for Hernia Repair. Macromol Biosci 2022; 22:e2200124. [PMID: 35766012 DOI: 10.1002/mabi.202200124] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 05/18/2022] [Indexed: 11/10/2022]
Abstract
Hernia injuries are the main condition where mesh implants are needed to provide a suitable reinforcement of the damaged tissue. Mesh implants made of polypropylene (PP) are widely used for this application, however complications related to lack of flexibility, elasticity, and mesh infection have been reported. The development of mesh implants from safer materials adaptable to patient necessities can suppose an alternative for conventional PP meshes. In this work, personalized mesh implants made of alginate and waterborne-polyurethane (A-WBPU) are developed using 3D printing technology. For that purpose, five waterborne polyurethane ink formulations with different amounts of alginate are developed and rheologically characterized. All ink formulations are 3D printed showing good printability, manufacturing surgical mesh implants with suitable morphological characteristics customizable to patient injury through computer-aided design (CAD) mesh model adaptation. A calcium chloride (CaCl2 ) coating is applied after 3D printing as mesh reinforcement. Mechanical analysis revealed that CaCl2 coated meshes containing 6 wt % of alginate in their formulation are the most suitable to be used as implants for small and groin hernias under physiological tensile strength value of 16 N cm-1 , and presenting proper elasticity to cover physiological corporal movements (42.57 %). Moreover, an antibiotic-loaded A-WBPU formulation suitable for 3D printing of meshes are developed as strategy to avoid possible mesh infection.
Collapse
Affiliation(s)
- Raquel Olmos-Juste
- 'Materials + Technologies' Research Group (GMT), Department of Chemical and Environmental Engineering, Faculty of Engineering of Gipuzkoa, University of the Basque Country, Plaza Europa 1, Donostia-San Sebastian, 20018, Spain
| | - Sheila Olza
- Department of Cell Biology and Histology, Faculty of Medicine and Dentistry, University of the Basque Country, Barrio Sarriena s/n, Leioa, 48940, Spain
| | - Nagore Gabilondo
- 'Materials + Technologies' Research Group (GMT), Department of Chemical and Environmental Engineering, Faculty of Engineering of Gipuzkoa, University of the Basque Country, Plaza Europa 1, Donostia-San Sebastian, 20018, Spain
| | - Arantxa Eceiza
- 'Materials + Technologies' Research Group (GMT), Department of Chemical and Environmental Engineering, Faculty of Engineering of Gipuzkoa, University of the Basque Country, Plaza Europa 1, Donostia-San Sebastian, 20018, Spain
| |
Collapse
|
16
|
Jourdan A, Rapacchi S, Guye M, Bendahan D, Masson C, Bège T. Dynamic-MRI quantification of abdominal wall motion and deformation during breathing and muscular contraction. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 217:106667. [PMID: 35231757 DOI: 10.1016/j.cmpb.2022.106667] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 01/15/2022] [Accepted: 01/25/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Biomechanical assessment of the abdominal wall represents a major prerequisite for a better understanding of physiological and pathological situations such as hernia, post-delivery recovery, muscle dystrophy or sarcopenia. Such an assessment is challenging and requires muscular deformations quantification which have been very scarcely reported in vivo. In the present study, we intended to characterize abdominal wall deformations in passive and active conditions using dynamic MRI combined to a semiautomatic segmentation procedure. METHODS Dynamic deformations resulting from three complementary exercises i.e. forced breathing, coughing and Valsalva maneuver were mapped in a transversal abdominal plane and so for twenty healthy volunteers. Real-time dynamic MRI series were acquired at a rate of 182 ms per image, then segmented semi-automatically to follow muscles deformation through each exercise. Circumferential and radial strains of each abdominal muscle were computed from the geometrical characteristics' quantification, namely the medial axis length and the thickness. Muscular radial displacement maps were computed using image registration. RESULTS Large variations in circumferential and radial strains were observed for the lateral muscles (LM) but remained low for the rectus abdominis muscles (RA). Contraction phases of each exercise led to LM muscle shortening down to -9.6 ± 5.9% during Valsalva maneuver with a 16.2 ± 9.6% thickness increase. Contraction also led to inward radial displacement of the LM up to 9.9 ± 4.1 mm during coughing. During maximal inhalation, a significant 10.0 ± 6.6% lengthening was quantified for LM while a significant thickness decrease was computed for the whole set of muscles (-14.7 ± 6.6% for LM and -7.3 ± 6.5% for RA). The largest displacement was observed for the medial part of RA (17.9 ± 8.0 mm) whereas the posterior part of LM underwent limited motion (2.8 ± 2.3 mm). Displacement rate and correlation between muscle thickness and medial axis length during each exercise provided insights regarding subject-specific muscle function. CONCLUSIONS Dynamic MRI is a promising tool for the assessment of the abdominal wall motion and deformations. The corresponding metrics which have been continuously recorded during the exercises provided global and regional quantitative information. These metrics offer perspectives for a genuine clinical evaluation tool dedicated to the assessment of abdominal muscles function in both healthy subjects and patients.
Collapse
Affiliation(s)
- Arthur Jourdan
- Aix-Marseille Univ, Univ Gustave Eiffel, IFSTTAR, LBA, F-13016 Marseille, France.
| | | | - Maxime Guye
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France; APHM, Hopital Universitaire Timone, CEMEREM, Marseille, France.
| | | | - Catherine Masson
- Aix-Marseille Univ, Univ Gustave Eiffel, IFSTTAR, LBA, F-13016 Marseille, France.
| | - Thierry Bège
- Aix-Marseille Univ, Univ Gustave Eiffel, IFSTTAR, LBA, F-13016 Marseille, France; Department of General Surgery, Aix Marseille Univ, North Hospital, APHM, Marseille, France.
| |
Collapse
|
17
|
Kirilova-Doneva M, Pashkouleva D. The effects of age and sex on the elastic mechanical properties of human abdominal fascia. Clin Biomech (Bristol, Avon) 2022; 92:105591. [PMID: 35131681 DOI: 10.1016/j.clinbiomech.2022.105591] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 12/19/2021] [Accepted: 01/28/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND The abdominal hernias become more prevalent with age, that can adversely affect life quality. The mechanical properties of abdominal wall layers are supposed to play a significant role in developing of an abdominal hernia.The objective of this study was to determine the mechanical properties of the human abdominal layer - fascia and the effects of age and sex on it for choosing the proper brand of hernia mesh. METHODS 78 samples harvested from 19 fresh cadavers were subjected to uniaxial tension tests and divided into four groups according to age. Group A corresponds to age up to 60 years, Group B to age 61-70 years, Group C to age 71-80 years and Group D to 81-90 years. Median stress-stretch ratio curves with respect to age, sex and direction of loading were obtained. Median values of the maximum tensile stress, stretch at maximum stress and elastic modulus calculated at 5% strain were determined. FINDINGS The abdominal fascia showed large variations between specimens depending on age and sex. The stiffness of the fascia increased with age. There is statistically significant differences between the median curves of male samples (P = 0.008) and female samples (P = 0.019) according to age in the L direction. Statistically significant differences between the values of maximum stress (P = 0.01) and elastic modulus (P = 0.003) from Group C in the L direction and maximum stress (P = 0.03) from Group D in the T direction was established. INTERPRETATION The female samples are stiffer than male samples especially after 80 years.
Collapse
Affiliation(s)
- Miglena Kirilova-Doneva
- Faculty of Pharmacy, Medical University-Sofia, Sofia, Bulgaria; Institute of Mechanics, Bulgarian Academy of Sciences, Sofia, Bulgaria.
| | | |
Collapse
|
18
|
Pérez-Köhler B, Benito-Martínez S, Gómez-Gil V, Rodríguez M, Pascual G, Bellón JM. New Insights into the Application of 3D-Printing Technology in Hernia Repair. MATERIALS 2021; 14:ma14227092. [PMID: 34832493 PMCID: PMC8623842 DOI: 10.3390/ma14227092] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 11/18/2021] [Accepted: 11/19/2021] [Indexed: 12/29/2022]
Abstract
Abdominal hernia repair using prosthetic materials is among the surgical interventions most widely performed worldwide. These materials, or meshes, are implanted to close the hernial defect, reinforcing the abdominal muscles and reestablishing mechanical functionality of the wall. Meshes for hernia repair are made of synthetic or biological materials exhibiting multiple shapes and configurations. Despite the myriad of devices currently marketed, the search for the ideal mesh continues as, thus far, no device offers optimal tissue repair and restored mechanical performance while minimizing postoperative complications. Additive manufacturing, or 3D-printing, has great potential for biomedical applications. Over the years, different biomaterials with advanced features have been successfully manufactured via 3D-printing for the repair of hard and soft tissues. This technological improvement is of high clinical relevance and paves the way to produce next-generation devices tailored to suit each individual patient. This review focuses on the state of the art and applications of 3D-printing technology for the manufacture of synthetic meshes. We highlight the latest approaches aimed at developing improved bioactive materials (e.g., optimizing antibacterial performance, drug release, or device opacity for contrast imaging). Challenges, limitations, and future perspectives are discussed, offering a comprehensive scenario for the applicability of 3D-printing in hernia repair.
Collapse
Affiliation(s)
- Bárbara Pérez-Köhler
- Departamento de Medicina y Especialidades Médicas, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain; (B.P.-K.); (S.B.-M.)
- Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain; (V.G.-G.); (M.R.); (J.M.B.)
- Ramón y Cajal Health Research Institute (IRYCIS), 28034 Madrid, Spain
| | - Selma Benito-Martínez
- Departamento de Medicina y Especialidades Médicas, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain; (B.P.-K.); (S.B.-M.)
- Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain; (V.G.-G.); (M.R.); (J.M.B.)
- Ramón y Cajal Health Research Institute (IRYCIS), 28034 Madrid, Spain
| | - Verónica Gómez-Gil
- Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain; (V.G.-G.); (M.R.); (J.M.B.)
- Departamento de Cirugía, Ciencias Médicas y Sociales, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain
- Departamento de Ciencias Biomédicas, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain
| | - Marta Rodríguez
- Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain; (V.G.-G.); (M.R.); (J.M.B.)
- Ramón y Cajal Health Research Institute (IRYCIS), 28034 Madrid, Spain
- Departamento de Cirugía, Ciencias Médicas y Sociales, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain
| | - Gemma Pascual
- Departamento de Medicina y Especialidades Médicas, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain; (B.P.-K.); (S.B.-M.)
- Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain; (V.G.-G.); (M.R.); (J.M.B.)
- Ramón y Cajal Health Research Institute (IRYCIS), 28034 Madrid, Spain
- Correspondence:
| | - Juan Manuel Bellón
- Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain; (V.G.-G.); (M.R.); (J.M.B.)
- Ramón y Cajal Health Research Institute (IRYCIS), 28034 Madrid, Spain
- Departamento de Cirugía, Ciencias Médicas y Sociales, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28805 Alcalá de Henares, Spain
| |
Collapse
|
19
|
A novel in vivo approach to assess strains of the human abdominal wall under known intraabdominal pressure. J Mech Behav Biomed Mater 2021; 125:104902. [PMID: 34717119 DOI: 10.1016/j.jmbbm.2021.104902] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 11/23/2022]
Abstract
The study concerns mechanical behaviour of a living human abdominal wall. A better mechanical understanding of a human abdominal wall and recognition of its material properties is required to find mechanically compatible surgical meshes to significantly improve the treatment of ventral hernias. A non-invasive methodology, based on in vivo optical measurements is proposed to determine strains of abdominal wall corresponding to a known intraabdominal pressure. The measurement is performed in the course of a standard procedure of peritoneal dialysis. A dedicated experimental stand is designed for the experiment. The photogrammetric technique is employed to recover the three-dimensional surface geometry of the anterior abdominal wall at the initial and terminal instants of the dialysis. This corresponds to two deformation states, before and after filling the abdominal cavity with dialysis fluid. The study provides information on strain fields of living human abdominal wall. The inquiry is aimed at principal strains and their directions, observed at the level from -10% to 17%. The intraabdominal pressure related to the amount of introduced dialysis fluid measured within the medical procedure covers the range 11-18.5 cmH2O. The methodology leads to the deformation state of the abdominal wall according to the corresponding loading conditions. Therefore, the study is a step towards an identification of mechanical properties of living human abdominal wall.
Collapse
|
20
|
Nienhuijs SW, Berkvens EHM, de Vries Reilingh TS, Mommers EHH, Bouvy ND, Wegdam J. The male rectus diastasis: a different concept? Hernia 2021; 25:951-956. [PMID: 34297251 DOI: 10.1007/s10029-021-02467-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 07/16/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE More interest in the treatment of rectus diastasis has been evoked lately. Following the postpartum females from a great distance, the middle-aged males living with obesity are the second most common group of rectus diastasis patients. Although gender differences are considered frequently in regard to cosmetic appearance and symptoms, it is less obvious in classifications and subsequent treatment strategies. Is a unisex approach of rectus diastasis still applicable? The lack of a firm answer warrants this review of the current literature. METHODS An explorative free-text multi-database bibliographic search (Pubmed/CENTRAL/EMBASE/PEDro/Scholar) was performed with the focus on the rectus diastasis in males. Anticipating the limited references, the design was a non-systematic review. All studies, regardless of study type, language or time period, describing etiology, symptoms, classification and/or treatment options were eligible for inclusion. From the articles retrieved out of this search, additional references were identified by a manual search among the cited references. RESULTS The multi-database search resulted in a total of 7633 records. Based on the title and abstract 95 records were full text assessed for eligibility. Eleven studies were identified as relevant, six by cross-reference and another four by hand-search were added to provide an insight in gender-specific aspects in rectus diastase. Hereditary causes are differences in collagen-like composition of types and concomitant abdominal aneurysm as well as gender differences in the linea alba architecture. Acquired etiology is distributed into both absolute pressure by visceral obesity and relative pressure caused by weight lifting or improper exercises. Furthermore, the impact of muscle thickness and age are considered as influencers of biomechanics. Gender differences can also play a role in symptoms of body image and core stability. It is known that there are anatomical differences between male and female persons; more transverse fibers are found in infra-umbilical region in women. In classifications the awareness of male rectus diastasis is limited, treatment outcome studies are scarce on males. CONCLUSION An overview of male-specific aspects of rectus diastasis is provided, underlining that key aspects surrounding rectus diastasis in males differ from females. Although males are the minority of rectus diastasis patients, we recommend that the male rectus diastasis as a concept should be specifically acknowledged in classifications systems and study outcome reporting to evaluate this subgroup more accurately in the future.
Collapse
Affiliation(s)
- S W Nienhuijs
- Department of Surgery, Catharina Hospital Eindhoven, Michelangelolaan 2, Eindhoven, 5623 EJ, The Netherlands.
| | - E H M Berkvens
- Department of Physiotherapy, Elkerliek Hospital Helmond, Helmond, The Netherlands
| | | | - E H H Mommers
- Department of Radiology, Maastricht University Hospital, Maastricht, The Netherlands
| | - N D Bouvy
- Department of Surgery, Maastricht University Hospital, Maastricht, The Netherlands
| | - J Wegdam
- Department of Surgery, Elkerliek Hospital Helmond, Helmond, The Netherlands
| |
Collapse
|
21
|
He W, Cao G, Gan X, Fan Y, Pei B, Li X. Evaluation methods for mechanical biocompatibility of hernia repair meshes: respective characteristics, application scope and future perspectives. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY 2021; 13:1826-1840. [DOI: 10.1016/j.jmrt.2021.05.086] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2025]
|
22
|
Morch A, Astruc L, Mayeur O, Witz JF, Lecomte-Grosbras P, Brieu M. Is there any objective and independent characterization and modeling of soft biological tissues? J Mech Behav Biomed Mater 2020; 110:103915. [PMID: 32771881 DOI: 10.1016/j.jmbbm.2020.103915] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 04/28/2020] [Accepted: 06/04/2020] [Indexed: 10/23/2022]
Abstract
The characterization of soft tissue raises several difficulties. Indeed, soft biological tissues usually shrink when dissected from their in vivo location. This shrinkage is characteristic of the release of residual stresses, since soft tissues are indeed often pre-stressed in their physiological configuration. During experimental loading, large extension at very low level of force are expected and assumed to be related to the progressive recruitment and stretching of fibers. However, the first phase of the mechanical test is also aiming at recovering the pre-stressed in vivo behavior. As a consequence, the initial phase, corresponding to the recovering of prestress and/or recruitment of fiberes, is questionable and frequently removed. One of the preferred methods to erase it consists in applying a preforce or prestress to the sample: this allows to easily get rid of the sample retensioning range. However this operation can impact the interpretation of the identified mechanical parameters. This study presents an evaluation of the impact of the data processing on the mechanical properties of a numerically defined material. For this purpose, a finite element simulation was performed to replicate a uniaxial tensile test on a biological soft tissue sample. The influence of different pre-stretches on the mechanical parameters of a second order Yeoh model was investigated. The Yeoh mechanical parameters, or any other strain energy density, depend strongly on any pre- and post-processing choices: they adapt to compensate the error made when choosing an arbitrary level of prestretch or prestress. This observation spreads to any modeling approach used in soft tissues. Mechanical parameters are indeed naturally bound to the choice of the pre-stretch (or pre-stress) through the elongation and the constitutive law. Regardless of the model, it would therefore be pointless to compare mechanical parameters if the conditions for the processing of experimental raw data are not fully documented.
Collapse
Affiliation(s)
- A Morch
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 LaMcube Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France
| | - L Astruc
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 LaMcube Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France
| | - O Mayeur
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 LaMcube Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France
| | - J-F Witz
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 LaMcube Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France
| | - P Lecomte-Grosbras
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 LaMcube Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France.
| | - M Brieu
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 LaMcube Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France; California State University, Los Angeles College Engineering, Computer Science and Technology, Dept. Mechanical Engineering, USA
| |
Collapse
|
23
|
Lubowiecka I, Tomaszewska A, Szepietowska K, Szymczak C, Śmietański M. In vivo performance of intraperitoneal onlay mesh after ventral hernia repair. Clin Biomech (Bristol, Avon) 2020; 78:105076. [PMID: 32535476 DOI: 10.1016/j.clinbiomech.2020.105076] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 05/01/2020] [Accepted: 06/04/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. METHODS This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures show the trunk of the patient at rest in a standing position and under side bending. The change in the distance between different tacks due to trunk movement was analyzed, which allowed us to determine the in vivo elongation of the mesh incorporated into the abdominal wall. FINDINGS The relative elongations of the surgical mesh varied from a few percent to greater than 100% in two cases. The median of the median relative elongations obtained for all patients is 9.5%, and the median of the maximum relative elongations for all patients is 32.6%. The maximum elongation occurs between tacks that are next to each other. Trunk movement causes implant deformation, and this study provides quantitative information regarding changes in the distance between fasteners. INTERPRETATION The physiological movement of the human abdomen must be regarded as a very important factor in mesh deformation and should be considered in surgical practice to reduce the hernia recurrence rate and postoperative pain.
Collapse
Affiliation(s)
- Izabela Lubowiecka
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gdańsk, Poland.
| | - Agnieszka Tomaszewska
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gdańsk, Poland
| | - Katarzyna Szepietowska
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Gdańsk, Poland
| | - Czesław Szymczak
- Gdansk University of Technology, Faculty of Ocean Engineering and Ship Technology, Gdańsk, Poland
| | - Maciej Śmietański
- Medical University of Gdańsk, 2(nd) Department of Radiology, Hospital Swissmed S.A., Department of Surgery, Poland
| |
Collapse
|
24
|
A numerical method for guiding the design of surgical meshes with suitable mechanical properties for specific abdominal hernias. Comput Biol Med 2020; 116:103531. [PMID: 31739005 DOI: 10.1016/j.compbiomed.2019.103531] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 10/18/2019] [Accepted: 11/04/2019] [Indexed: 11/19/2022]
|
25
|
Liu P, Fu K, Zeng X, Chen N, Wen X. Fabrication and Characterization of Composite Meshes Loaded with Antimicrobial Peptides. ACS APPLIED MATERIALS & INTERFACES 2019; 11:24609-24617. [PMID: 31199612 DOI: 10.1021/acsami.9b07246] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Biomaterials-centered infection or implant-associated infection plays critical roles in all areas of medicine with implantable devices. The widespread over use of antibiotics has caused severe bacterial resistance and even super bugs. Therefore, the development of anti-infection implantable devices with non-antibiotic-based new antimicrobial agents is indeed a priority for all of us. In this study, antimicrobial composite meshes were fabricated with broad-spectrum antimicrobial peptides (AMPs). Macroporous polypropylene meshes with poly-caprolactone electrospun nanosheets were utilized as a substrate to load AMPs and gellan gum presented as a media to gel with AMPs. Different amounts of AMPs were loaded onto gellan gum to determine the appropriate dose. The surface morphologies, Fourier-transform infrared spectroscopy spectra, in vitro release profiles, mechanical performances, in vitro antimicrobial properties, and cytocompatibility of composite scaffolds were evaluated. Results showed that AMPs were loaded into the meshes successfully, the in vitro release of AMPs in phosphate-buffered saline was prolonged, and less than 60% peptides were released in 10 days. The mechanical properties of composite meshes were also within the scope of several commercial surgical meshes. Composite meshes with the AMP loading amount of over 3 mg/cm2 showed inhibition against both Gram-negative and Gram-positive bacteria effectively, while they presented no toxicity to mammalian cells even at a loading amount of 10 mg/cm2. These results demonstrate a new simple and practicable method to offer antimicrobial properties to medical devices for hernia repair.
Collapse
Affiliation(s)
- Pengbi Liu
- College of Textiles , Donghua University , Shanghai 201620 , P. R. China
- Department of Chemical and Life Science Engineering, School of Engineering , Virginia Commonwealth University , Richmond , Virginia 23284 , United States
| | - Kun Fu
- Department of Chemical and Life Science Engineering, School of Engineering , Virginia Commonwealth University , Richmond , Virginia 23284 , United States
- Department of Stomatology , The First Affiliated Hospital of Zhengzhou University , Zhengzhou , Henan 450052 , P. R. China
| | - Xiaomei Zeng
- Department of Chemical and Life Science Engineering, School of Engineering , Virginia Commonwealth University , Richmond , Virginia 23284 , United States
| | - Nanliang Chen
- College of Textiles , Donghua University , Shanghai 201620 , P. R. China
| | - Xuejun Wen
- Department of Chemical and Life Science Engineering, School of Engineering , Virginia Commonwealth University , Richmond , Virginia 23284 , United States
- Beijing Ditan Hospital , Capital Medical University , Beijing 100015 , P. R. China
| |
Collapse
|