1
|
Buser R, Dönmez MB, Hoffmann M, Hampe R, Stawarczyk B. Fatigue behavior and reliability of pressed lithium disilicate ceramics compared to 5Y-TZP zirconia under different loading protocols. Dent Mater 2025; 41:134-140. [PMID: 39617643 DOI: 10.1016/j.dental.2024.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2024] [Revised: 11/11/2024] [Accepted: 11/27/2024] [Indexed: 01/20/2025]
Abstract
OBJECTIVE To compare the fatigue behavior and reliability of 5 pressed lithium disilicate ceramics and a 5 mol% yttria-stabilized zirconia (5Y-TZP) when 3 dynamic loading protocols were used. METHODS Bar-shaped specimens (30 × 4 × 3 mm) were fabricated from 5 pressed lithium disilicate ceramics (AMB, CEL, INI, IPS, and LIV) and a 5Y-TZP (ZR) (N = 324). Six specimens from each material were subjected to a static 4-point fracture load test, while the remaining specimens were subjected dynamic loading by increasing the starting load (30 % of the static fracture load) in every 5000 cycles by 50 N (loading protocol 1), in every 5000 cycles by 5 % (loading protocol 2) or in every 1000 cycles by 10 N (loading protocol 3) until fracture (n = 16). The fracture load, flexural strength, and number of cycles until failure were analyzed with 2-way analysis of variance and Scheffé tests. The survival rate was evaluated with Kaplan-Meier analysis and further compared with Mantel-Cox test, while the correlation between the fracture load and flexural strength was analyzed with Pearson's correlation test (α = 0.05). Fractographic analysis was also performed. RESULTS The interaction between the materials and the loading protocol affected the number of cycles until failure, while the material type affected fracture load and flexural strength values (P < 0.001). ZR had the highest and LIV mostly had lower fracture load and flexural strength (P ≤ 0.034). A positive correlation was found between the fracture load and flexural strength (r = 0.997, P < 0.001). For lithium disilicate ceramics, loading protocol 2 and for ZR, loading protocols 1 and 3 led to the highest number of cycles and survival rate (P ≤ 0.041). Regardless of the loading protocol, all lithium disilicate ceramics had a similar fragmentation pattern with single compression curls and 2-piece fractures were observed. SIGNIFICANCE Tested materials are suitable for adhesively luted monolithic single-unit prosthesis as they had mean flexural strength values higher than 100 MPa. Measuring the fracture load with loading protocol 3 can be considered time-efficient to evaluate the fatigue behavior of pressed lithium disilicate ceramics.
Collapse
Affiliation(s)
- Ramona Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Mustafa Borga Dönmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, Faculty of Dentistry, Biruni University, İstanbul, Turkey.
| | - Moritz Hoffmann
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Rüdiger Hampe
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, Munich, Germany
| |
Collapse
|
2
|
Jurado CA, Bora PV, Azpiazu-Flores FX, Cho SH, Afrashtehfar KI. Effect of resin cement selection on fracture resistance of chairside CAD-CAM lithium disilicate crowns containing virgilite: A comparative in vitro study. J Prosthet Dent 2025; 133:203-207. [PMID: 37739880 DOI: 10.1016/j.prosdent.2023.08.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 08/21/2023] [Accepted: 08/22/2023] [Indexed: 09/24/2023]
Abstract
STATEMENT OF PROBLEM Studies on the fracture performance of a recently introduced computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate ceramic containing virgilite with different cements are lacking. PURPOSE The purpose of this in vitro study was to evaluate the fracture resistance of crowns made of a recently introduced chairside CAD-CAM lithium disilicate containing virgilite cemented with different types of adhesive luting cement. MATERIAL AND METHODS Sixty complete coverage crowns for a maxillary right central incisor were milled out of a lithium disilicate with virgilite (CEREC Tessera) (n=48) and a traditional lithium disilicate (e.max CAD) (n=12) using a chairside CAD-CAM system (Primescan). The central incisor tooth preparation included a 1.5-mm incisal reduction, a 1.0-mm axial reduction, and a 1.0-mm chamfer finish line. The restorations were bonded with different types of resin cement to 3D printed dies of the tooth preparation and were divided into 5 groups (n=12 per group): e.max CAD with Multilink Automix (E.Mu); Tessera with Multilink Automix (T.Mu); Tessera with Calibra (T.Ca); Tessera with Unicem (T.Un); and Tessera with Speedcem (T.Sp). The cemented restorations were stored in water for 30 days and then loaded until they were fractured in compression. The load at fracture was analyzed with a 1-way analysis of variance (ANOVA) and the honestly significant difference (HSD) Tukey test (α=.05). RESULTS The mean fracture resistance of traditional lithium disilicate and virgilite lithium disilicate anterior crowns significantly differed depending on the type of resin cement used (P<.05). Group E.Mu displayed the highest values (946.35 ±155 N), followed by group T.Un (819.59 ±232 N), group T.Sp (675.52 ±153 N), and group T.Mu (656.95 ±193 N). The lowest values were displayed by group T.Ca (567.94 ±184 N). CONCLUSIONS The fracture resistance of lithium disilicate containing virgilite and traditional lithium disilicate crowns cemented with the same cement displayed statistically similar values. However, significant differences were observed when the virgilite lithium disilicate crowns were cemented with different types of adhesive luting cement. The crowns in the T.Ca group displayed the lowest fracture resistance.
Collapse
Affiliation(s)
- Carlos A Jurado
- Clinical Associate Professor, Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa.
| | - Pranit V Bora
- Resident, Master of Sciences in Dental Materials Program, School of Dentistry, University of Alabama at Birmingham, Birmingham, Ala.
| | - Francisco X Azpiazu-Flores
- Assistant Professor, Department of Restorative Dentistry, Gerald Niznick College of Dentistry, University of Manitoba, Winnipeg, Manitoba, Canada; ITI Scholar, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind.
| | - Seok-Hwan Cho
- Associate Professor and Department Chair, Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa.
| | - Kelvin I Afrashtehfar
- Assistant Professor and Director of Evidence-Based Practice Unit, Clinical Sciences Department, College of Dentistry, Ajman University, Ajman City, AE, United Arab Emirates; Adjunct Research Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Senior Scientific Researcher, Artificial Intelligence Research Center (AIRC), Ajman University, Dubai, United Arab Emirates; and Visiting Professor, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea..
| |
Collapse
|
3
|
Ereifej NS, Musa DB, Oweis YG, Abu-Awwad M, Tabnjh AK. The influence of core-build up materials on biaxial flexural strength of strength-gradient zirconia and lithium disilicate ceramics: an in-vitro study. Sci Rep 2024; 14:30115. [PMID: 39627323 PMCID: PMC11615382 DOI: 10.1038/s41598-024-82030-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Accepted: 12/02/2024] [Indexed: 12/06/2024] Open
Abstract
The aim of this study was to investigate the effect of using different core build-up materials on biaxial flexural strength (BFS) of multilayered strength-gradient zirconia ceramic in comparison to lithium disilicate ceramic. Thirty zirconia discs were fabricated from IPS e.max ZirCAD Prime (Zir), 30 discs from IPS e.max CAD (LS2), 30 composite discs were prepared from Tetric N-Ceram (TNC) and 30 from MultiCore Flow (MCF). The ceramic discs were adhesively cemented to composite discs forming 4 groups (n = 15) (Zir-MCF, Zir-TNC, LS2-MCF and LS2-TNC). BFS was determined using a piston-on-3-ball test. The data were statistically analyzed with independent t-tests for significant differences (p = 0.05). In zirconia groups, significantly higher stress values were recorded in the composite and the ceramic for Zir-TNC, compared to Zir-MCF (p < 0.001), while for LS2 groups, no significant differences were found between the 2 composites (p = 0.157) but stresses in LS2 were significantly higher for LS2-TNC than LS2-MCF (p < 0.001). Comparing the values between the ceramic groups, stresses were significantly higher for zirconia than LS2 (p < 0.001). It was concluded that the tested composite materials significantly differ in their strength, which also influenced the strength of the overlying ceramics, and that strength-gradient zirconia had higher strength than LS2. Monolithic strength-gradient zirconia restorations supported by composite core build-up materials with superior mechanical properties can be durable restorative options for high stress-bearing areas.
Collapse
Affiliation(s)
- Nadia S Ereifej
- Department of Prosthetic Dentistry, Faculty of Dentistry, The University of Jordan, Queen Rania Street, Amman, 11942, Jordan.
| | | | - Yara G Oweis
- Department of Restorative Dentistry, Faculty of Dentistry, The University of Jordan, Amman, Jordan
| | - Motasum Abu-Awwad
- Department of Applied Dental Sciences, Faculty of Applied Medical Science, Jordan University of Science and Technology, Irbid, Jordan
| | - Abedelmalek K Tabnjh
- Department of Applied Dental Sciences, Faculty of Applied Medical Science, Jordan University of Science and Technology, Irbid, Jordan
| |
Collapse
|
4
|
Moreira PM, Carvalho GLM, de Castro Albuquerque R, André CB. Effect of hydrofluoric acid and self-etch ceramic primers on the flexural strength and fatigue resistance of glass ceramics: A systematic review and meta-analysis of in vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2024; 60:198-210. [PMID: 39027733 PMCID: PMC11254839 DOI: 10.1016/j.jdsr.2024.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 05/06/2024] [Accepted: 06/04/2024] [Indexed: 07/20/2024] Open
Abstract
This systematic review evaluated the effect of different hydrofluoric acid (HF) etching regimens and a self-etch ceramic primer (SECP) on the flexural strength (FS) and fatigue failure load (FFL) of glass-ceramic materials.The identification of relevant studies was conducted by two authors in five databases: PubMED, Scopus, Web Of Science, LILACS and Virtual Health Library (BVS) until July 2022 with no year limit. The analysis was conducted in RevMan 5.4.1 Software (Cochrane Collaboration) using Random effect model at 5 %. The risk of bias of the included studies were assessed. From the 5349 articles identified, 34 were included for quantitative analysis. Meta-analysis showed that for predominantly glassy ceramics, etching with HF 5 % had no significant impact on FS, however, HF acid etching with concentrations greater than 5 % negatively impacted FS. For lithium disilicate glass-ceramics (LDGC) HF acid etching, negatively influenced FS, while increasing the FFL. HF etching negatively affected FS of hybrid ceramics. The self-etch ceramic primer and HF acid etching showed a similar impact on FFL and FS. This meta-analysis indicates that the impact of SECP and HF acid etching on the mechanical behavior of glass ceramics is material-dependent.
Collapse
Affiliation(s)
- Paulo Matias Moreira
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | | | - Rodrigo de Castro Albuquerque
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Carolina Bosso André
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| |
Collapse
|
5
|
Çınar Ş, Altan Çınar B, Güneş Bağlan G, Yıldırım E. Effect of different surface conditioning methods and low pH solutions on the shear bond strength of orthodontic brackets to newly introduced CAD/CAM materials. Heliyon 2024; 10:e40018. [PMID: 39553625 PMCID: PMC11565453 DOI: 10.1016/j.heliyon.2024.e40018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 10/21/2024] [Accepted: 10/30/2024] [Indexed: 11/19/2024] Open
Abstract
Aim To evaluate the shear bond strength (SBS) of ceramic and metallic orthodontic brackets bonded to lithium disilicate ceramics or hybrid ceramics and subjected to different surface conditioning treatments. Materials and methods In total, 300 specimens were fabricated from GC LiSi (lithium disilicate) and GC Cerasmart (hybrid) ceramic blocks. The specimens were divided into four groups according to the following surface treatments: hydrofluoric acid (HF); sandblasting with 50 μm aluminum oxide; Monobond Etch and Prime; and erbium-doped yttrium aluminum garnet (Er-YAG) laser. Metal (Victory Series) and ceramic (Clarity) brackets were bonded using an orthodontic adhesive resin (Transbond XT; 3M Unitek, CA, USA). The specimens were then stored in three different mediums (artificial saliva, mouth rinse, and gastric juice) and thermocycled. An SBS test was performed after 1 week. The surface morphology was examined after the conditioning treatments using a scanning electron microscope. Data were analyzed using analysis of variance, t-test, and Duncan test. Results The SBS data revealed that the type of computer-aided design/computer-aided manufacturing (CAD/CAM) block and surface conditioning method significantly affected the SBS. The highest SBS was recorded (10.112 MPa) for the HF-treated hybrid ceramic blocks stored in the saliva medium, while the lowest SBS (1.862 MPa) was reported for the Er-YAG laser-treated lithium disilicate ceramic blocks stored in the gastric juice medium. GC Cerasmart exhibited better bond strength than that of GC LiSi; however, no significant difference was observed between the ceramic and metal brackets. Conclusion The CAD/CAM material, surface conditioning method, and medium affect the SBS.
Collapse
Affiliation(s)
- Şevki Çınar
- Department of Prosthodontics, Faculty of Dentistry, University of Health Sciences, Tıbbiye Street No: 38, 34668, Uskudar, Istanbul, Turkey
| | - Bike Altan Çınar
- Department of Prosthodontics, Faculty of Dentistry, University of Health Sciences, Tıbbiye Street No: 38, 34668, Uskudar, Istanbul, Turkey
| | - Gökçe Güneş Bağlan
- Department of Prosthodontics, Faculty of Dentistry, University of Health Sciences, Tıbbiye Street No: 38, 34668, Uskudar, Istanbul, Turkey
| | - Ersin Yıldırım
- Department of Orthodontics, Faculty of Dentistry, University of Health Sciences, Turkey
| |
Collapse
|
6
|
Alzahrani KM. Effect of resin cement viscosities and surface roughness on shear bond strength of conditioned polymer infiltrated ceramic network. Photodiagnosis Photodyn Ther 2024; 49:104333. [PMID: 39245304 DOI: 10.1016/j.pdpdt.2024.104333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Revised: 09/01/2024] [Accepted: 09/06/2024] [Indexed: 09/10/2024]
Abstract
BACKGROUND Hybrid ceramics bonding with the dentinal substrate is crucial for clinical success and longevity. To enhance adhesion, the surface of ceramic restorations is modified through various conditioning techniques AIM: Effect of Different Surface Conditioners Erbium-doped yttrium aluminum garnet (ER: YAG) laser and Low-level laser therapy (LLLT) activated Methylene blue (MB) on the surface roughness (Ra) and shear bond strength (SBS) of Polymer infiltrating ceramic network (PICN) discs bonded using different viscosity resin cement before and after thermal aging. MATERIAL AND METHODS One hundred and fifty human central incisors and one hundred and fifty-three PICN discs were prepared. PICN discs were randomly allocated into three groups based on the surface conditioning(n = 51) Group 1:10 % HF acid-S, Group 2: LLLT (MB), and Group 3: Er: YAG laser. Following conditioning Ra scores of ten samples were performed. Surface topography of samples was performed using a scanning electron microscope (SEM). Bonding of forty PICN discs from each conditioning group was performed with high (A) or low viscosity (B) dual-curing resin cement (n = 20 each). Each subgroup was divided into two cohorts and subjected to varying storage conditions. The SBS test and failure mode analysis were performed using a universal testing machine and stereomicroscope. Descriptive statistics of SBS and Ra for each group were analyzed using ANOVA and Tukey post hoc tests. HF acid-S attained the highest Ra scores. RESULTS Group 1A (HF-S+HIGH) samples achieved the highest SBS values at baseline. Group 3A, on the other hand, displayed the lowest bond score (Er: YAG laser+HIGH) after thermal aging. Intergroup comparison analysis at baseline unveiled that Group 1A and Group 1B (HF(S) + LOW) displayed no significant difference in their bond strength scores (p>0.05). Following artificial aging, it was observed that Group 2A (LLLT (MB) + HIGH) and Group 3A (Er:YAG laser + HIGH) ) presented comparable SBS(p > 0.05). Thermal aging decreased SBS significantly in all groups. PICN conditioned with HF-S results in high surface roughness. CONCLUSION PICN conditioned with HF acid with silane and bonded with low-viscosity resin cement to the dentinal substrate is preferable. Aging influences SBS.
Collapse
Affiliation(s)
- Khaled M Alzahrani
- Department of Prosthetic Dental Sciences, College of Dentistry Prince Sattam Bin Abdulaziz University, 11942 Alkharj, Saudi Arabia.
| |
Collapse
|
7
|
Chandy TS, Driscoll C, Masri R. Effect of silver diamine fluoride on the surface roughness of dental ceramics. J Prosthet Dent 2024; 132:614-622. [PMID: 36372584 DOI: 10.1016/j.prosdent.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 10/03/2022] [Accepted: 10/04/2022] [Indexed: 11/11/2022]
Abstract
STATEMENT OF PROBLEM Application of silver diamine fluoride (SDF) can be a straightforward and efficient way to manage recurrent caries around the margins of crowns. However, its effect on ceramic surfaces is unknown. PURPOSE The purpose of this in vitro study was to evaluate and compare the effect of SDF, acidulated phosphate fluoride (APF), and distilled water on the surface roughness of dental ceramics. MATERIAL AND METHODS Forty-five rectangles (10×10×2 mm) each of 5% yttria-stabilized tetragonal zirconia polycrystal (5Y-TZP) zirconia (Zir), lithium disilicate (LDS), overglazed feldspathic porcelain (FO), and polished feldspathic porcelain (FP) were fabricated. The specimens were treated with 38% SDF, 1.23% APF, and distilled water to simulate 3 years of topical applications. The surface roughness (Ra) of each rectangle was measured with a profilometer before and after treatment with the solutions, and the change in Ra (△Ra) was calculated. Scanning electron microscope images were obtained of each treatment group. Multiple comparison of the means among the ceramics and testing solutions was done using 2-way ANOVA followed by the Tukey Honestly Significant test (α=.05). RESULTS ANOVA revealed significant differences in the 2 main factors, as well as their interaction (P<.001). The surface roughness of the treated rectangles was significantly dependent on the type of ceramic and the testing solution. The greatest surface roughness increase was seen in the interaction of LDS:APF (△Ramean=0.51 ±0.13 μm), closely followed by FO:APF (△Ramean=0.49 ±0.20 μm) and FP:APF (△Ramean=0.41 ±0.17 μm) (P<.001). SDF increased the surface roughness of LDS, FO, and FP; however, the increase was not significant (△Ramean LDS=0.25 ±0.11 μm; △Ramean FO=0.17 ±0.16 μm; △Ramean FP=.1 ±0.14 μm; P >.118). None of the solutions had any effect on zirconia (P>.977). CONCLUSIONS SDF is safe to use around zirconia restorations. Long-term and repeated application of SDF on lithium disilicate and feldspathic porcelain must be considered with caution.
Collapse
Affiliation(s)
- Tintu Sara Chandy
- Fellow, Maxillofacial Prosthetics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Carl Driscoll
- Clinical Professor, Postgraduate Prosthodontics, School of Dentistry, University of Maryland, Baltimore, Md
| | - Radi Masri
- Professor and Director, Postgraduate Prosthodontics, School of Dentistry, University of Maryland, Baltimore, Md.
| |
Collapse
|
8
|
Pilecco RO, da Rosa LS, Baldi A, Machry RV, Tribst JPM, Valandro LF, Kleverlaan CJ, Scotti N, Pereira GKR. How do different intraoral scanners and milling machines affect the fit and fatigue behavior of lithium disilicate and resin composite endocrowns? J Mech Behav Biomed Mater 2024; 155:106557. [PMID: 38657286 DOI: 10.1016/j.jmbbm.2024.106557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/03/2024] [Accepted: 04/17/2024] [Indexed: 04/26/2024]
Abstract
The aim of this in vitro study was to evaluate the effect of the combinations of two different intraoral scanners (IOS), two milling machines, and two restorative materials on the marginal/internal fit and fatigue behavior of endocrowns produced by CAD-CAM. Eight groups (n= 10) were considered through the combination of TRIOS 3 (TR) or Primescan (PS) IOS; 4-axes (CR; CEREC MC XL) or 5-axes (PM; PrograMill PM7) milling machines; and lithium disilicate (LD; IPS e.max CAD) or resin composite (RC; Tetric CAD) restorative materials. Specific surface treatments were applied to each material, and the bonding to its corresponding Endocrown-shaped fiberglass-reinforced epoxy resin preparations was performed (Variolink Esthetic DC). Computed microtomography (μCT) was performed to assess the marginal/internal fit, as well as a mechanical fatigue test (20 Hz, initial load = 100 N/5000 cycles; step-size = 50 N/10,000 cycles until a threshold of 1500 N, then, the step-size was increased if needed to 100 N/10,000 cycles until failure or a threshold of 2800 N) to evaluate the restorations long-term behavior. Complementary analysis of the fracture features and surface topography in scanning electron microscopy was performed. Three-way ANOVA and Kaplan-Meier test (α = 0.05) were performed for marginal/internal fit, and fatigue behavior data, respectively. PS scanner, CR milling machine, and RC endocrowns resulted in a better marginal fit compared to their counterparts. Still, the PM machine resulted in a better pulpal space fit compared to the CR milling machine. Regardless of the scanner and milling machine, RC endocrowns exhibited superior fatigue behavior than LD ones. LD endocrowns presented margin chipping regardless of the milling machine used. Despite minor differences in terms of fit, the 'IOS' and 'milling machine' factors did not impair the fatigue behavior of endocrowns. Resin-composite restorations resulted in a higher survival rate compared to glass-ceramic ones, independently of the digital devices used in the workflow.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andrea Baldi
- Department of Surgical Sciences, Dental School, University of Turin (UNITO), Turin, Piedmont, Italy.
| | - Renan Vaz Machry
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands.
| | - Nicola Scotti
- Department of Surgical Sciences, Dental School, University of Turin (UNITO), Turin, Piedmont, Italy.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
9
|
Temp RW, Packaeser MG, Machry RV, Dapieve KS, Rippe MP, Pereira GKR, Valandro LF. Characteristic fatigue strength and reliability of dental glass-ceramics: Effect of distinct surface treatments - Hydrofluoric acid etching and silane treatment vs one-step self-etching ceramic primer. J Mech Behav Biomed Mater 2024; 150:106338. [PMID: 38159495 DOI: 10.1016/j.jmbbm.2023.106338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/14/2023] [Accepted: 12/16/2023] [Indexed: 01/03/2024]
Abstract
The aim of this study was to mechanically characterize through flexural fatigue test two CAD-CAM glass-ceramics according to distinct surface etching protocols. To do so, feldspathic (FELD) and lithium disilicate (LD) glass ceramics were subjected to different surface treatments: (1) control - no treatment (Ctrl); (2) conventional protocol etching with 5% hydrofluoric acid followed by silane coupling agent application (HF + SIL; Monobond N, Ivoclar); or (3) using a self-etching ceramic primer (E&P; Monobond Etch & Prime, Ivoclar). Ceramic discs (N = 120; Ø = 12 mm; thickness = 1.2 mm) were produced from CAD-CAM blocks, with 60 being from FELD (VITABLOCS Mark II, Vita Zahnfabrik) and 60 from LD (IPS e.max CAD, Ivoclar). Next, 20 disks of each ceramic were allocated into three groups: Ctrl, HF + SIL, or E&P. Surface roughness data were collected on all samples before and after surface treatments (except for Ctrl). Cyclic fatigue (n = 15) biaxial flexural strength tests were performed by the piston-on-three-balls geometry (ISO 6872) considering the test parameters established from a monotonic test (n = 5). The monotonic test was carried out at a 1 mm/min loading rate and 500 kgf loading cell until fracture to obtain the failure data. The cyclic fatigue test was executed underwater at a frequency up to 20 Hz, with the first stress being 25% of the monotonic test for 5000 cycles, followed by increments of 5% of the monotonic test at each step of 10,000 cycles until failure (fracture). Complementary fractography, topography and Atomic Force Microscopy (AFM) analyses were performed. Characteristic Fatigue Strength (CFS) and Weibull modulus were analyzed by Weibull analysis using the fatigue test data. Roughness and complementary analysis data were analyzed by one-way ANOVA. The statistical results exhibited similar CFS among Ctrl, HF + SIL and E&P for both glass-ceramics. The survival analysis corroborates the findings, however the Weibull modulus pointed out superior structural reliability of FELD treated with the E&P group compared to HF + SIL. According to the complementary analyses, HF + SIL exhibited a higher surface area than E&P and Ctrl for FELD (p = 0.001). Roughness showed statistically significant differences among conditions for FELD (E&P < Ctrl = HF + SIL; p < 0.05) and no difference for LD (p > 0.05). Therefore, the CFS were not influenced by any condition evaluated for FELD and LD glass-ceramics; however, superior structural reliability (higher Weibull modulus) for the feldspathic ceramic treated with the E&P was observed.
Collapse
Affiliation(s)
- Renatta Wrasse Temp
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Maria Gabriela Packaeser
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Renan Vaz Machry
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Kiara Serafini Dapieve
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Marilia Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontic Unit), Faculty of Odontology, Center for Development of Advanced Materials, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
10
|
Dalla-Nora F, Da Rosa LS, Pereira GKR, Valandro LF, Rippe MP. Is dentin analogue material a viable substitute for human dentin in fatigue behavior studies? J Mech Behav Biomed Mater 2024; 150:106312. [PMID: 38134583 DOI: 10.1016/j.jmbbm.2023.106312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/04/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023]
Abstract
This study aimed to compare the fatigue performance of a lithium disilicate ceramic cemented on different substrates (human dentin and glass fiber-reinforced epoxy resin - GFRER), treated with different types of conditioning (CTR - without surface conditioning; HF5 - 5% hydrofluoric acid; HF10 - 10% hydrofluoric acid; H3PO4 - phosphoric acid 37%; SAND - sandblasting with aluminum oxide). The occlusal surface of human molars (DENT group) (n = 15) was ground for dentin exposure and the root portion was cut, then the dentin slice (2.0 mm thick) was conditioned with 37% phosphoric acid and a dual-curing dental adhesive was applied. The GFRER in a round-rod format was cut into discs (Ø = 10 mm, 2.0 mm thick). Lithium disilicate glass ceramic blocks (IPS e.max CAD, Ivoclar, Schaan, Liechtenstein) were shaped into a cylinder format and cut, resulting in 90 discs (Ø = 10 mm, 1.5 mm thick). The substrate materials of each group were etched according to the groups and the ceramic was etched with 5% hydrofluoric acid for 30 s. A silane coupling agent was applied over the cementation surface in ceramic and GFRER surfaces and a dual cement was used for cementation (ceramic/GFRER or dentin). The disc/disc sets were submitted to thermocycling (25,000 cycles + storage for 6 months), and then tested in step-wise accelerated cyclic fatigue test. The failure pattern and topography were analyzed and the roughness and contact angle were measured before and after surface treatment. The DENT group presented the lowest load to failure values and number of cycles to failure in fatigue (637.33 N; 118.333), showing no statistical similarity with any of the other tested groups (p < 0.05). The topographic analysis showed that all proposed surface treatments modified the substrate surface when compared to the CTR group. All of the fractographical inspections demonstrated failure by radial crack. Considering the roughness analysis, the post-etched DENT group showed similar roughness to all groups of GFRER materials with their surface treated, except for SAND, which showed greater roughness and statistically different from the other groups. The DENT group (49.5) showed statistically different post-conditioning contact angle values from the HF10 group (96.5) and similar to the other groups. The glass fiber-reinforced epoxy resin was not able to simulate the results presented by the human dentin substrate when cemented to lithium disilicate regarding fatigue failure load and number of cycles for failure, regardless of the surface treatment. Lithium disilicate cemented on dentin analogue overestimates the load values for fatigue failure.
Collapse
Affiliation(s)
- F Dalla-Nora
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - L S Da Rosa
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - G K R Pereira
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - L F Valandro
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - M P Rippe
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
11
|
Maqbool B, Rego HMC, Santos GC, Ari N, Santos MJMC. Effect of different surface treatment protocols on the bond strength between lithium disilicate and resin cements. Odontology 2024; 112:74-82. [PMID: 37036616 DOI: 10.1007/s10266-023-00809-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 03/24/2023] [Indexed: 04/11/2023]
Abstract
Because the use of hydrofluoric acid (HF) poses health risks if handled improperly, many clinicians prefer to have the ceramic restorations pre-etched in dental laboratories. However, during the try-in procedure, the pre-etched glass-ceramic restorations may be contaminated with saliva resulting in reduced bond strength. This in-vitro study aimed to investigate the effect of different surface treatments on the bond strength of lithium disilicate (LD) glass-ceramic restorations (IPS e.max Press, Ivoclar Vivadent) to two resin cements. One-hundred eighty blocks (4X4X3mm) of LD glass-ceramic were divided into twelve groups (n = 15), of which six received Variolink Esthetic DC (VE) cement and six received RelyX Ultimate (RU) cement, following the surface treatments: G1) Control: Hydrofluoric Acid + Silane (HF + Sil); G2) Hydrofluoric Acid + Saliva + Silane (HF + S + Sil); G3) Hydrofluoric Acid + Saliva + Ivoclean + Silane (HF + S + IC + Sil); G4) Hydrofluoric Acid + Saliva + Phosphoric Acid + Silane (HF + S + P + Sil); G5) Hydrofluoric Acid + Saliva + Monobond Etch & Prime (HF + S + EP); G6) Monobond Etch & Prime (EP). Following treatment, a resin-cement cylinder (2.3 mm diameter) was built on the glass-ceramic surface, photocured (20 s), stored in distilled water (37 °C, 24 h) and submitted to the shear bond strength test. Bond strength data (MPa) were subjected to two-way ANOVA and Tukey (α = 0.01). Cement type and surface treatment had a significant effect on the bond strength (p < 0.001) (Table 4). Single-step Monobond Etch & Prime (EP) significantly improved the bond strength of resin-cements to glass-ceramic with and without saliva contamination.
Collapse
Affiliation(s)
- Bilal Maqbool
- Schulich Medicine and Dentistry, Western University, London, ON, Canada
| | - Heleine Maria Chagas Rego
- Department of Restorative Dentistry, Schulich Medicine and Dentistry, Western University, DSB, London, ON, N6A 5C1, Canada
| | - Gildo Coelho Santos
- Department of Restorative Dentistry, Schulich Medicine and Dentistry, Western University, DSB, London, ON, N6A 5C1, Canada
| | - Nilgun Ari
- Department of Restorative Dentistry, Schulich Medicine and Dentistry, Western University, London, ON, Canada
| | | |
Collapse
|
12
|
Tomm AGF, Machado PS, Rosa LSD, Pereira GKR, Spazzin AO, Alessandretti R. Fatigue resistance of monolithic and multilayer zirconia crowns using veneer layering or CAD-on technique. Braz Dent J 2023; 34:150-159. [PMID: 38133089 PMCID: PMC10742353 DOI: 10.1590/0103-6440202305687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 11/24/2023] [Indexed: 12/23/2023] Open
Abstract
This study aims to evaluate the fatigue resistance of monolithic zirconia (Yz) and multilayer ceramic structures using the CAD-on technique in different thicknesses. Fifty (N=50) standardized single crowns preparations were made in fiberglass-reinforced epoxy resin (NEMA grade G10), digitalized, and restorations were machined in CAD-CAM, composing 5 groups (n= 10): Control: 1.5 mm (milled zirconia framework + manual layered porcelain); Yz monolithic 1.5 mm; Yz monolithic 1.0 mm; CAD-on 1.5 mm; and CAD-on 1.0 mm (milled zirconia framework 0.5 mm thickness bonded by a low fuse ceramic to a milled lithium disilicate layer of 1.0 mm or 0.5 mm, respectively). The G10 bases were conditioned with 10% hydrofluoric acid; the crowns were air abraded with 110 μm alumina particles; and then luted onto each other with self-adhesive resin cement. A cyclic fatigue test was performed (initial load: 400N for 10,000 cycles, frequency of 20 Hz, step size of 200N) until failure, and the data was submitted to a survival statistical analysis. No failures were observed at Yz monolithic 1.5 mm. High and similar performance was observed for Cad-On groups and Yz monolithic 1.0 mm. The control group depicted the worst behavior. The Weibull modulus of CAD-on 1.5 mm was higher than the control while being similar to the other conditions. Both the monolithic systems and the CAD-on technique showed high and similar fatigue fracture behavior and survival rates, which were also higher than the control bilayer system. Both systems reduced the occurrence of delamination failures, making them suitable for clinical use.
Collapse
Affiliation(s)
| | - Pablo Soares Machado
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Center for Development of Advanced Materials, Division of Prosthodontics-Biomaterials, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | | | | |
Collapse
|
13
|
Alves WG, Souza LFB, Pereira GKR, Valandro LF, Kapczinski MP, Mengatto CM, Fraga S. Fit and fatigue behavior of CAD-CAM lithium disilicate crowns. J Prosthet Dent 2023; 130:241.e1-241.e8. [PMID: 37328406 DOI: 10.1016/j.prosdent.2023.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 05/19/2023] [Accepted: 05/19/2023] [Indexed: 06/18/2023]
Abstract
STATEMENT OF PROBLEM New computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate glass-ceramics have been marketed. However, information concerning their biomechanical behavior is lacking. PURPOSE The purpose of this in vitro study was to compare the fit and fatigue behavior of two recently introduced CAD-CAM lithium disilicate materials with the standard IPS e.max CAD ceramic and to investigate the effect of the thermal treatment for crystallization on crown fit. MATERIAL AND METHODS Monolithic crowns (n=15) were milled from 3 CAD-CAM lithium disilicates: IPS e.max CAD (Ivoclar AG), Rosetta SM (Hass), and T-lithium (Shenzhen Upcera Dental Technology). Marginal and internal fit were evaluated using the replica technique before and after crystallization, and the fatigue behavior of the luted crowns was evaluated by the step-stress method. One-way ANOVA and the Tukey test were used to compare fit among the materials. Fatigue failure load was evaluated by the Kaplan-Meier and Mantel-Cox tests. The effect of crystallization on fit was evaluated with the paired t test (α=.05). RESULTS Marginal fit was different between IPS e.max CAD (74 μm) and Rosetta SM (63 μm) (P=.02). T-lithium was similar to the other ceramics (68 μm) (P>.05). Occlusal internal space was similar among all materials (P=.69). Fatigue failure loads of Rosetta SM (1160 N) and T-lithium (1063 N) were similar to IPS e.max CAD (1082 N) (P>.05). The fatigue failure load of Rosetta SM was higher than that of T-lithium (P=.04). Crystallization reduced the axial internal space of all materials (P<.05) without significantly affecting marginal fit (P>.05). CONCLUSIONS The fit and fatigue behavior of Rosetta SM and T-lithium were similar to that of IPS e.max CAD. Crystallization reduced the internal space of the crowns.
Collapse
Affiliation(s)
- William Garcia Alves
- Graduate student, Department of Conservative Dentistry, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Luiza Freitas Brum Souza
- Postgraduate Student, Post-Graduate Program in Dental Science, Prosthodontics Unit, Department of Restorative Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, Department of Restorative Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Luiz Felipe Valandro
- Professor, Department of Restorative Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Myriam Pereira Kapczinski
- Associate Professor, Department of Conservative Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Cristiane Machado Mengatto
- Associate Professor, Department of Conservative Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Sara Fraga
- Adjunct Professor, Department of Conservative Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil.
| |
Collapse
|
14
|
Marini G, Saldanha da Rosa L, Machado PS, Silvestre FA, Valandro LF, Feitosa VP, Pereira GKR, Bacchi A. Fatigue performance analysis of strength-graded zirconia polycrystals for monolithic three-unit implant-supported prostheses. J Mech Behav Biomed Mater 2023; 140:105736. [PMID: 36801783 DOI: 10.1016/j.jmbbm.2023.105736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Revised: 02/10/2023] [Accepted: 02/13/2023] [Indexed: 02/16/2023]
Abstract
The aim of this study was to evaluate the fatigue behavior of strength-graded zirconia polycrystals used as monolithic three-unit implant-supported prosthesis; complementarily, crystalline phase and micromorphology were also assessed. Fixed prostheses with 3 elements supported by 2 implants were confectioned, as follows: Group 3Y/5Y - monolithic structures of a graded 3Y-TZP/5Y-TZP zirconia (IPS e.max® ZirCAD PRIME); Group 4Y/5Y - monolithic structures of a graded 4Y-TZP/5Y-TZP zirconia (IPS e.max® ZirCAD MT Multi); Group Bilayer - framework of a 3Y-TZP zirconia (Zenostar T) veneered with porcelain (IPS e.max Ceram). The samples were tested for fatigue performance with step-stress analysis. The fatigue failure load (FFL), the number of cycles required until failure (CFF), and the survival rates in each cycle were recorded. The Weibull module was calculated and the fractography analyzed. The crystalline structural content via Micro-Raman spectroscopy and the crystalline grain size via Scanning Electron microscopy were also assessed for graded structures. Group 3Y/5Y showed the highest FFL, CFF, probability of survival, and reliability (based on Weibull modulus). Group 4Y/5Y showed significantly superior FFL and probability of survival than group bilayer. Fractographic analysis revealed catastrophic flaws in the monolithic structure and cohesive fracture of porcelain in bilayer prostheses, all originating from the occlusal contact point. The graded zirconia presented small grain size (≤0.61 μm), with the smallest values at the cervical region. The main composition of graded zirconia was of grains at tetragonal phase. The strength-graded monolithic zirconia, especially the 3Y-TZP/5Y-TZP, showed to be promising for use as monolithic three-unit implant-supported prosthesis.
Collapse
Affiliation(s)
- Gabriel Marini
- Post-Graduate Program in Dentistry, Atitus Education, Passo Fundo, RS, Brazil
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Dental Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil
| | - Pablo Soares Machado
- Post-Graduate Program in Dental Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil
| | | | - Luiz Felipe Valandro
- Post-Graduate Program in Dental Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil
| | - Victor Pinheiro Feitosa
- Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry (FACPP), Fortaleza, CE, Brazil
| | | | - Atais Bacchi
- Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry (FACPP), Fortaleza, CE, Brazil.
| |
Collapse
|
15
|
Sağlam G, Cengiz S, Köroğlu A, Şahin O, Velioğlu N. Comparison of the Micro-Shear Bond Strength of Resin Cements to CAD/CAM Glass Ceramics with Various Surface Treatments. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2635. [PMID: 37048927 PMCID: PMC10095943 DOI: 10.3390/ma16072635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/15/2023] [Accepted: 03/24/2023] [Indexed: 06/19/2023]
Abstract
This study aimed to compare the effect of acid etching, sandblasting, or silica coating on the micro-shear bond strength of dual-cured resin cements to computer-aided design and computer-aided manufacturing (CAD/CAM) glass ceramic materials. Feldspathic, lithium disilicate, and zirconia-reinforced CAD/CAM ceramics were divided into four groups: control group (C), no surface treatment; hydrofluoric (HF) group, 5% HF acid-etched; sandblasting (SB) group, abraded with 50 µm aluminum oxide (Al2O3) particles; silica-coated (CJ) group, abraded with 30 µm silica-modified Al2O3 particles. Roughness values were obtained by using a profilometer. The cements were condensed on the surface-treated specimens and a micro-shear bond test was conducted. The ceramic material (p < 0.001) and surface treatment type (p < 0.001) significantly affected the micro-shear bond strength values. HF acid etching can be recommended for the surface pretreatment of feldspathic, lithium disilicate, and zirconia-reinforced CAD/CAM ceramics. Better bond strengths can be obtained with HF acid etching than with sandblasting and silica coating.
Collapse
Affiliation(s)
- Gaye Sağlam
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
| | - Seda Cengiz
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
| | - Ayşegül Köroğlu
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
| | - Onur Şahin
- Department of Prosthodontics, DCT Clinic, Antalya 07000, Turkey
| | - Neslin Velioğlu
- Department of Prosthodontics, Navadent Oral and Dental Health Policlinic, Zonguldak 67000, Turkey
| |
Collapse
|
16
|
Dapieve KS, Velho HC, da Rosa LS, Pivetta JP, Maidana FC, Venturini AB, Kleverlaan CJ, Pereira GKR, Valandro LF. Ceramic surface conditioning, resin cement viscosity, and aging relationships affect the load-bearing capacity under fatigue of bonded glass-ceramics. J Mech Behav Biomed Mater 2023; 139:105667. [PMID: 36657192 DOI: 10.1016/j.jmbbm.2023.105667] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/03/2023] [Accepted: 01/05/2023] [Indexed: 01/09/2023]
Abstract
This study aimed to evaluate the influence of ceramic surface treatments, resin cement viscosities, and storage regimens on the fatigue performance of bonded glass-ceramics (lithium disilicate, LD; feldspathic, FEL). Ceramic discs (Ø = 10 mm; thickness = 1.5 mm) were allocated into eight groups per ceramic (n = 15), considering three factors: "ceramic surface treatment" in two levels - 5% hydrofluoric acid etching and silane-based coupling agent application (HF), or self-etching ceramic primer (E&P); "resin cement viscosity" in two levels - in high or low viscosity; and "storage regimen" in two levels - baseline, 24 h to 5 days; or aging, 180 days + 25,000 thermal cycles. Adhesive luting was performed onto glass fiber-reinforced epoxy resin discs (Ø = 10 mm; thickness = 2 mm) and the bonded assemblies were subjected to cyclic fatigue tests: initial load = 200 N; step-size = 25 N (FEL) and 50 N (LD); 10,000 cycles/step; 20 Hz. Scanning electron microscopy (SEM) inspections were performed. Regarding the LD ceramic, the fatigue behavior was reduced after aging for HF_HIGH and E&P_LOW conditions, while stable performance was observed for HF_LOW and E&P_HIGH. Regarding the FEL results, aging negatively affected HF_HIGH, E&P_HIGH, and E&P_LOW, being that only the HF_LOW condition presented a stable behavior. The failure initiated from defects on the etched surface of the ceramics, where the cross-sectional analysis commonly revealed unfilled areas. Long-term aging might induce a decrease in mechanical behavior. The 'ceramic microstructure/surface conditioning/resin cement viscosity relationships' modulate the fatigue performance of lithium disilicate and feldspathic glass-ceramics.
Collapse
Affiliation(s)
- Kiara Serafini Dapieve
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Helder Callegaro Velho
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Jordana Pavanelo Pivetta
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Cocco Maidana
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andressa Borin Venturini
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North-Holland, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
17
|
Pilecco RO, Zucuni CP, Carvalho ABGD, Saavedra GDSFA, Marinho RMDM, Rocha Pereira GK, Valandro LF. Polishing the bonding surface, before or after crystallization, does not alter the fatigue behavior of bonded CAD-CAM lithium disilicate. J Mech Behav Biomed Mater 2023; 142:105794. [PMID: 37037152 DOI: 10.1016/j.jmbbm.2023.105794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 03/17/2023] [Accepted: 03/19/2023] [Indexed: 04/08/2023]
Abstract
The aim of this study was to assess if the finishing/polishing of the bonding surface of lithium disilicate ceramic, prior to or after crystallization, would affect the fatigue behavior of a bonded restorations. For this, lithium disilicate ceramic (IPS e.max CAD) discs (n = 15) were milled and randomly divided into 3 groups: CAD-CAM group which remained untouched; PRE group which received a finishing/polishing protocol (OptraFine system) prior to its crystallization; and POST group, which received the treatment after its crystallization. After surface treatments, ceramic and glass-fiber reinforced epoxy resin discs were paired and bonded using a resin cement (Multilink N). A cyclical fatigue test was conducted (frequency 20 Hz, initial load 200 N for 5000 cycles, step-size of 100 N for 10,000 cycles/step) until failure occurrence. Surface roughness and topography were analyzed. An initial descriptive analysis of surface roughness, FFL and CFF was performed to obtain the mean, standard deviation and confidence interval values (SPSS v. 21, SPSS Inc.) for statistical analysis. Roughness data was using one-way ANOVA with Tukey's post hoc test (α = 0.05), while the fatigue data was submitted to survival analysis with Kaplan-Meier test (α = 0.05) and Weibull modulus (Weibull++, Reliasoft). Neither the finishing/polishing procedure of the bonding surface, nor the moment (prior to or after crystallization), affected the fatigue behavior of bonded milled lithium disilicate. There were also no differences for mechanical reliability among conditions. Despite this, finishing/polishing reduced surface roughness and led to smoother topography. Finishing/polishing the bonding surface of milled lithium disilicate, before or after crystallization, does not alter the fatigue behavior of the bonded restorative set, although there is some influence on roughness and topography.
Collapse
|
18
|
da Rosa LS, Velho HC, Tribst JPM, Valandro LF, Kleverlaan CJ, Pereira GKR. Weak adhesion between ceramic and resin cement impairs the load-bearing capacity under fatigue of lithium disilicate glass-ceramic crowns. J Mech Behav Biomed Mater 2023; 138:105604. [PMID: 36509013 DOI: 10.1016/j.jmbbm.2022.105604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/28/2022] [Accepted: 12/01/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To evaluate the fatigue behavior of lithium disilicate crowns with a simplified anatomy against progressive cement/ceramic debonding scenarios. MATERIALS AND METHODS Lithium disilicate crowns were fabricated via CAD/CAM and luted onto a dentin analogue material using resin cement following the manufacturer's instructions. Then, the different crown regions were isolated with paraffin oil for the absence of chemical adhesion according to four experimental groups (n = 15): Shoulder; Shoulder + Axial; Fully isolated; and Control (no insulation/fully bonded). Load to failure tests (n = 3) were run to determine cyclic fatigue parameters, and the specimens were subsequently submitted to a cyclic fatigue test (n = 12) (initial load 200 N for 5000 cycles, step 100 N, 15,000 cycles/step, frequency 20 Hz) until cracks were observed, and later fracture. The data were analyzed by Kaplan-Meier + Mantel-Cox post-hoc tests for both outcomes (cracks and fracture). Fractographic, cross-sectional surface, and finite element (FEA) analyzes were performed. RESULTS When it comes to crack occurrence when the chemical adhesion to the occlusal surface is compromised, there is worsening (p < 0.05) in fatigue behavior compared to groups where the occlusal portion of the crown is still bonded. Considering fracture occurrence, there was no difference (p > 0.05) among the tested groups. All cracks occurred in the occlusal portion, first as a radial crack at the ceramic intaglio surface, and posteriorly unleashing a Hertzian cone crack at the top surface, resulting in fractures on the frontal walls. The interface analysis showed no interference of the insulating agent. FEA showed that as the isolated areas increased, there was also an increase in both tensile and shear stresses concentration in the crown and in the cement layer. CONCLUSION The chemical adhesion between cement and ceramic is essential for better fatigue behavior of lithium disilicate crowns with a simplified anatomy, especially in the occlusal portion, but the restoration performance is impaired when such adhesion is compromised. There is an increase in crown and cement stress concentration with the progressive loss of chemical bonding of the crown's walls.
Collapse
Affiliation(s)
- Lucas Saldanha da Rosa
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Helder Callegaro Velho
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - João Paulo Mendes Tribst
- Academic Centre for Dentistry Amsterdam (ACTA), Department of Oral Regenerative Medicine, University of Amsterdam and Vrije Universiteit Amsterdam, 1081 LA, Amsterdam, the Netherlands.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| | - Cornelis Johannes Kleverlaan
- Academic Centre for Dentistry Amsterdam (ACTA), Department of Dental Material Sciences, University of Amsterdam and Vrije Universiteit Amsterdam, 1081 LA, Amsterdam, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Sciences, Federal University of Santa Maria (UFSM), Santa Maria, RS, Brazil.
| |
Collapse
|
19
|
A brief review on fatigue test of ceramic and some related matters in Dentistry. J Mech Behav Biomed Mater 2023; 138:105607. [PMID: 36549251 DOI: 10.1016/j.jmbbm.2022.105607] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/28/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022]
Abstract
The characteristics of dental ceramics have been extensively studied over the years to provide highly qualified materials for use in prosthetic restorations. The ability to adhere to dental substrates, outstanding aesthetics (translucency, color, and substrate masking ability) and improved mechanical properties provide these materials with optical features and high strength to withstand masticatory stimuli. Different classifications are adopted, and it is generally considered that glass-ceramics have better optical characteristics due to the high glass content, and polycrystalline ceramics have superior strength favored by their densified and organized crystals, hampering crack growth. This knowledge was largely built-up during years of scientific research through different testing methodologies, but mainly employing static loads. It is important to not only take into account the intensity of loads that these materials will be exposed to, but also the effect of the intermittence of cyclic load application leading to mechanical fatigue and the influence of factors related to the crack origin and their propagation under this condition. Furthermore, the bonding surface of ceramic restorations requires surface treatments that improve the bond strength to luting agents; however, these treatments require caution because of their potential to produce defects and affect the structural behavior. Moreover, ceramic restorations often require internal adjustments for proper seating or external adjustments for fitting the occlusal contact with the antagonist. In this sense, finishing/polishing protocols may alter the defect population, as luting agents may also interact by filling in the superficial defects on the restoration intaglio surface. Thus, the balance among all these factors will define the performance of a restorative setup, as well as the posterior exposure to the humid environment and the masticatory stimuli (cyclical loading), which may favor developing slow and subcritical growth of cracks in ceramic materials and the degradation of the bond interface. Therefore, it is essential that the concepts which explain the fatigue mechanism are understood, as well as the crack propagation and failure patterns of restorative ceramic materials.
Collapse
|
20
|
Lampl S, Gurunathan D, Krithikadatta J, Mehta D, Moodley D. Reasons for Failure of CAD/CAM Restorations in Clinical Studies: A Systematic Review and Meta-analysis. J Contemp Dent Pract 2023; 24:129-136. [PMID: 37272145 DOI: 10.5005/jp-journals-10024-3472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
AIM The systematic review presented herein was performed to descriptively analyze the causes for the failure of computer-aided design/computer-aided manufacture (CAD/CAM) restorations. The meta-analysis reported herein was performed to estimate long-term survival and success rates of CAD-CAM fabrications. MATERIALS AND METHODS Using the PICOS paradigm, a systematic search was carried out in the PubMed and Cochrane databases to identify randomized controlled trials (RCTs) and prospective observational studies reporting survival data for CAD/CAM restorations. After selecting studies with a predefined set of selection criteria, data from included prospective clinical studies and RCTs were used for a systematic review aimed at a descriptive analysis of factors associated with failure of CAD-CAM restorations. Data from the included prospective clinical studies were used for meta-analysis, wherein 5-year and 10-year survival and success rates were estimated using Poisson regression models. RESULTS The systematic review included data from 9 RCTs and 6 observational studies, which had a median follow-up of 36 months and 60 months, respectively. About 58 failures and 118 technical/ biological complications were noted in the included RCTs and 9 failures along with 58 technical/biological complications were noted in the prospective clinical studies. Poisson regression indicated an estimated 5-year and 10-year survival rates of 85.55-100 and 71-100, respectively. The estimated 5-year and 10-year success rates were 74.2-92.75 and 33.3-85.5, respectively. CONCLUSION Several technical and biological complications contribute to failure of CAD/CAM restorations. However, CAD/CAM restorations with routine chairside materials might have clinically meaningful success rates in the long term. CLINICAL SIGNIFICANCE The results presented herein indicate that optimal strategies for mitigation of biological and technical complications may augment the success of CAD/CAM fabrications in restorative dentistry. Studies aimed at identification of such strategies are needed to further enhance the long-term success rates of CAD/CAM restorations.
Collapse
Affiliation(s)
- Stephan Lampl
- Department of Paediatric Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
| | - Deepa Gurunathan
- Department of Paediatric Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India, Phone: +91 9994619386, e-mail:
| | - Jogikalmat Krithikadatta
- Department of Paediatric Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
| | - Deepak Mehta
- Department of Conservative Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, India; Department of Operative Dentistry, Tohoku University Graduate School of Dentistry, Tohoku University, Sendai, Japan
| | | |
Collapse
|
21
|
Burgo TL, Pereira GKR, Iglesias BA, Moreira KS, Valandro LF. AFM advanced modes for dental and biomedical applications. J Mech Behav Biomed Mater 2022; 136:105475. [PMID: 36195052 DOI: 10.1016/j.jmbbm.2022.105475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 09/15/2022] [Accepted: 09/18/2022] [Indexed: 11/18/2022]
Abstract
Several analytical methods have been employed to elucidate bonding mechanisms between dental hard tissues, luting agents and restorative materials. Atomic Force Microscopy (AFM) imaging that has been extensively used in materials science, but its full capabilities are poorly explored by dental research community. In fact, commonly used to obtain topographic images of different surfaces, it turns out that AFM is an underestimated technique considering that there are dozens of basic and advanced modes that are scarcely used to explain properties of biomaterials. Thus, this paper addresses the use of phase-contrast imaging, force-distance curves, nanomechanical and Kelvin probe force techniques during AFM analysis to explore topological, nanomechanical and electrical properties of Y-TZP samples modified by different surface treatments, which has been widely used to promote adhesive enhancements to such substrate. The AFM methods are capable of access erstwhile inaccessible properties of Y-TZP which allowed us to describe its adhesive properties correctly. Thus, AFM technique emerges as a key tool to investigate the complex nature of biomaterials and highlighting its inherent interdisciplinarity that can be successfully used for bridging fragmented disciplines such as solid-state physics, microbiology and dental sciences.
Collapse
Affiliation(s)
- ThiagoA L Burgo
- Department of Chemistry and Environmental Sciences, Ibilce, São Paulo State University (Unesp), São Jose do Rio Preto, São Paulo State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and Ph.D. Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Bernardo Almeida Iglesias
- Department of Chemistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Kelly S Moreira
- Department of Chemistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- MSciD and Ph.D. Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
22
|
Abstract
The purpose of this study is to present current dental ceramic materials and processing methods. The clinical indication was emphasized on basis of the material's microstructure and composition. Studies of ceramic characterization were also discussed, as they impact the clinical indication and serve as a parameter for the development of new materials. The novel strategies were mostly found aiming to mimic the natural dental structures, provide mechanical reliability, and develop predictable restorations in terms of adaptation and design.
Collapse
Affiliation(s)
- Atais Bacchi
- Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry, Rua Joaquim Sá 900, Fortaleza, Ceará 60325-218, Brazil.
| | - Paulo Francisco Cesar
- Department of Biomaterials and Oral Biology, University of São Paulo - USP. Av Prof Lineu Prestes, 2227. Cidade Universitária, São Paulo, São Paulo 05508-000, Brazil
| |
Collapse
|
23
|
Velho HC, da Rosa LS, Temp RW, Cocco FM, Pereira GKR, May LG, Valandro LF. Adhesive application after ceramic surface treatment is detrimental to load-bearing capacity under fatigue of a lithium disilicate glass-ceramic. J Mech Behav Biomed Mater 2022; 135:105453. [PMID: 36126505 DOI: 10.1016/j.jmbbm.2022.105453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/30/2022] [Accepted: 09/03/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate whether an adhesive application after surface treatment on a lithium disilicate ceramic (LD) has an influence on its load-bearing capacity under fatigue. METHODS LD discs (Ø= 10 mm; thickness= 1 mm) were allocated into 8 groups (n= 15), considering 3 factors: "ceramic surface treatment" - HF: hydrofluoric acid + universal primer application; or MEP: single-component ceramic primer; "adhesive application" - with or without; and "aging protocol" - baseline: 24 h to 7 days; or aging: 180 days of storage + 25,000 thermal cycles. The LD discs were adhesively bonded to glass fiber-reinforced epoxy resin discs (Ø= 10 mm; thickness= 2 mm) and stored according to the condition and each group. Cyclic fatigue testing (initial load= 100 N; step size= 100 N until600 N and after step size= 25 N to failure; 10,000 cycles/step; 20 Hz frequency) was performed. Fractographic and adhesive interface analyzes were also performed. The collected data were then analyzed by Kaplan Meier and Mantel-Cox tests and One-way ANOVA. RESULTS The adhesive application in the baseline condition had no influence on the load-bearing capacity under fatigue when the HF surface treatment was performed, however, adhesive application for the MEP treatment led to worse results than without it. The adhesive application in the aged condition showed worse fatigue outcomes for both treatments. All specimens presented radial cracks. MEP treatment followed by adhesive application presented the thickest luting layer. CONCLUSION The adhesive application after surface treatments of a lithium disilicate glass-ceramic is detrimental to its load-bearing capacity under fatigue when adhesively luted onto a supporting substrate.
Collapse
Affiliation(s)
- Helder Callegaro Velho
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renatta Wrasse Temp
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Maidana Cocco
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Liliana Gressler May
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
24
|
Aragonez GC, Pilecco RO, Dapieve KS, Burgo TAL, Guilardi LF, Prochnow C, Valandro LF, Rippe MP. Simulation of CAD/CAM milling on lithium disilicate: Mechanical and topographic analyses of surface grinding different protocols. J Mech Behav Biomed Mater 2022; 132:105278. [PMID: 35653917 DOI: 10.1016/j.jmbbm.2022.105278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 05/14/2022] [Accepted: 05/17/2022] [Indexed: 10/18/2022]
Abstract
The aim of this study was to evaluate the topography and the fatigue performance of lithium disilicate glass-ceramic after surface grinding through different laboratory protocols used to simulate the Computer-aided design/Computer-aided manufacturing (CAD/CAM) milling. Ceramic discs (IPS e.max CAD, Ø = 13.5 mm × 1.2 mm of thickness) were produced through different methodologies: milling in CAD/CAM system (CAD/CAM group); produced in-lab with a polished surface (POL group); or produced through in-lab methods and randomly distributed into five groups according to different grinding protocols to simulate the CAD/CAM milling [grinding with a CAD/CAM bur coupled to a mandrel (CAD/CAM Bur group); fine diamond bur using oscillatory movements (DBO group); fine diamond bur in x and y axes of the disc (DBXY group); #60-grit silicon carbide sandpaper (SiC group); and #60-grit wood sandpaper (WS group)]. The specimens were fatigue tested (n = 15) according to the step-stress method (initial load: 60 N; step-size: 20 N; 10,000 cycles/step; 20 Hz frequency). A roughness analysis was performed on all specimens, while fractal dimension (FD) and fractography were performed on representative samples. The Kaplan-Meier analysis showed that the POL (293.3 N) group presented better fatigue performance (higher load and number of cycles for failure) (p < 0.05) than the other groups (CAD/CAM = 222.7 N; CAD/CAM Bur = 181.3 N; DBO = 184.0 N; DBXY = 192.0 N; SiC = 182.6 N; WS = 182.6 N). For roughness, only the SiC (Ra = 1.616; Rz = 10.465) and WS (Ra = 1.673; Rz = 10.655) groups produced statistically similar Ra (μm) and Rz (μm) values to the CAD/CAM (Ra = 1.628; Rz = 9.571) group (p > 0.05). The surface created by CAD/CAM milling and POL group exhibited more complexity (FD) higher values than the experimental groups. For the ceramic surface topography images, the CAD/CAM milling visibly produced a uniform surface compared to the other groups; however, the POL group was the smoothest. The DBO, DBXY, SiC, and WS groups resulted in similar characteristics of surface topography. Therefore, although the SiC and WS groups showed similar roughness to the control group (CAD/CAM), no in-lab simulation method was fully capable to mimic the mechanical performance of the CAD/CAM-milled lithium disilicate glass-ceramic.
Collapse
Affiliation(s)
- Gabriela Carrão Aragonez
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Rafaela Oliveira Pilecco
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Kiara Serafini Dapieve
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Thiago Augusto Lima Burgo
- Department of Physics, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luís Felipe Guilardi
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Catina Prochnow
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria - UFSM, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
25
|
Does adhesive luting promote improved fatigue performance of lithium disilicate simplified crowns? J Mech Behav Biomed Mater 2022; 134:105373. [PMID: 35868064 DOI: 10.1016/j.jmbbm.2022.105373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 07/14/2022] [Indexed: 11/22/2022]
Abstract
The present study aimed to determine the influence of adhesive luting on the fatigue mechanical properties of simplified lithium disilicate crowns luted to dentin analogues preparations, and to compare two different approaches of simulation of a non-adhesive luting procedure. To this end, 30 prosthetic preparations of glass fiber-filled epoxy resin used as dentin analogues were milled and lithium disilicate crowns were pressed (1.5 mm thickness), which were allocated into three different groups: resin cement (RC), resin cement isolated by paraffin oil (RCI) and zinc phosphate cement (ZP). For luting procedures, the ceramic crowns of the RC and RCI groups had their internal surface treated with 5% hydrofluoric acid and universal primer. Afterwards, a thin layer of paraffin oil was applied onto the ceramic crown intaglio surface in the RCI group. The dentin analogues were treated with 10% hydrofluoric acid, followed by primer application and luting as recommended by the manufacturer. No previous surface treatments were performed for the ZP group, and the cement was applied as recommended. The fatigue test was run under cyclic fatigue (load 400-2000 N, step-size 100 N, 15,000 cycles/step, frequency 20 Hz) until failure detection (radial crack) by transillumination. The fatigue failure load (FFL), number of cycles until failure (CFF), and survival rate in each testing step were recorded. The RC group presented a higher FFL, CFF and survival rate compared to the other groups (p < 0.001), which were statistically equal to each other (p > 0.05). Weibull analysis detected no difference between groups for the Weibull module. Therefore, loss of adhesion between the evaluated substrates induces a significant reduction in load-bearing capacity under fatigue of the lithium disilicate crowns, strengthening the strong-importance of long-lasting adhesion for crown's survival. In addition, different methods for the simulation of non-adhesive conditions induce the same performance in the explored outcomes, confirming that both are valid approaches for laboratory studies.
Collapse
|
26
|
Ottoni R, Marocho SMS, Griggs JA, Borba M. CAD/CAM versus 3D-printing/pressed lithium disilicate monolithic crowns: adaptation and fatigue behavior. J Dent 2022; 123:104181. [DOI: 10.1016/j.jdent.2022.104181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 05/13/2022] [Accepted: 06/06/2022] [Indexed: 10/18/2022] Open
|
27
|
PORTO BL, BARBON FJ, ISOLAN CP, BORGES AL, SPAZZIN AO, MORAES RR, BOSCATO N. Effect of ultrasound on preheated resin composites used as ceramic luting agents. Dent Mater J 2022; 41:451-458. [DOI: 10.4012/dmj.2021-246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Bruna L. PORTO
- Graduate Program in Dentistry, Universidade Federal de Pelotas
| | | | - Cristina P. ISOLAN
- School of Dentistry, Universidade Federal dos Vales do Jequitinhonha e Mucuri
| | | | | | | | - Noéli BOSCATO
- Graduate Program in Dentistry, Universidade Federal de Pelotas
| |
Collapse
|
28
|
Lithium disilicate and peek implant-retained single crowns - a randomized, prospective clinical study. SRP ARK CELOK LEK 2022. [DOI: 10.2298/sarh211110003j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Introduction/Objective. Comparing two materials under the same conditions is
the best way to define differences between them. PEEK is a polymer that has
many possible uses in dentistry as already well-known lithium disilicate
ceramics. The aim of this study was to compare peri-implant soft tissue
healing and evaluate patient satisfaction with esthetics in different
observation periods, as well as the success and survival rate of both types
of crowns. Methods. The study was conducted as a clinical, prospective,
randomized split-mouth study on 17 patients with bilaterally missing upper
teeth of the same type, replaced with dental implants. Study outcomes have
been analyzed with subjective (VAS scale) and objective parameters (MBI, MPI
and PPD) baseline, six and twelve months after fixing crowns onto the
implants. Results. Comparison of the results between PEEK and lithium
disilicate crowns showed no statistical differences in terms of MPI, MBI and
PPD in the observed periods. Analyzing MPI during observation periods in the
PEEK group of crowns, statistical significance was registered between
baseline values and after 6 months. Also, statistical significance was
noticed in terms of PPD during the observation time both in the study and
control group of crowns. Results for VAS for the esthetics showed no
statistically significant difference between the groups, while VAS for
restoration satisfaction showed a statistically significant difference.
Conclusion. This study showed that scores of the applied subjective and
objective parameters can be a reliable tool to rate the clinical outcome of
implant-retained single crowns over time.
Collapse
|
29
|
Dapieve KS, Pereira GKR, Venturini AB, Daudt N, Valcanaia A, Bottino MC, Valandro LF. Do resin cement viscosity and ceramic surface etching influence the fatigue performance of bonded lithium disilicate glass-ceramic crowns? Dent Mater 2021; 38:e59-e67. [PMID: 34969523 DOI: 10.1016/j.dental.2021.12.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 12/04/2021] [Accepted: 12/08/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To assess the effects of a resin cement in high and low viscosity and distinct conditioning of the intaglio surface of lithium disilicate glass-ceramic crowns on fatigue performance of the crowns. METHODS Prosthetic preparations (full-crown) in resin epoxy and crowns in lithium disilicate glass-ceramic were machined and allocated considering 2 factors (n = 10): "surface treatment" (HF - 5% hydrofluoric acid etching, followed by silane application; or E&P-self-etching ceramic primer) and "resin cement" (high or low viscosity). The preparations were etched with 10% hydrofluoric acid and an adhesive was applied. The intaglio surfaces of the ceramic crowns were treated as aforementioned (HF or E&P) and luted with high or low viscosity. The bonded sets were subjected to fatigue testing (step-stress approach: initial load of 200 N, step-size of 50 N, 10,000 cycles/step, 20 Hz) and complementary analyses (fractographic, topographic, and cross-sectional bonded interfacial zone analyses) were performed. RESULTS Treatment with HF and silane with high viscosity resin cement (955 N/156,000 cycles) and E&P with low viscosity resin cement (1090 N/183,000 cycles) showed the best fatigue performance (statistical similarity between them). The failures originated from defects of the cement-ceramic interface, and the HF treatment induced a more pronounced topographical alteration. SIGNIFICANCE Distinct topographical patterns from the HF and E&P treatments induced better fatigue results for the specific viscosity of the resin cement. Therefore, the fatigue performance depended on the existing topography, type of intaglio surface's defects/irregularities after surface treatment, and how the luting agent filled the irregularities.
Collapse
Affiliation(s)
- Kiara Serafini Dapieve
- Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Andressa Borin Venturini
- Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Natália Daudt
- Post-Graduate Program in Mechanical Engineering, Department of Mechanical Engineering, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - André Valcanaia
- Department of Cariology, Restorative Sciences and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.
| | - Marco Cícero Bottino
- Department of Cariology, Restorative Sciences and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Prosthetic Dentistry Unit, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
30
|
Machry RV, Cadore-Rodrigues AC, Packaeser MG, Lorenzett E, Burgo TADL, Pereira GKR, Valandro LF. Influence of surface treatment of resin composite substrate on the load-bearing capacity under fatigue of lithium disilicate monolithic simplified restorations. J Mech Behav Biomed Mater 2021; 124:104792. [PMID: 34488172 DOI: 10.1016/j.jmbbm.2021.104792] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/20/2021] [Accepted: 08/22/2021] [Indexed: 10/20/2022]
Abstract
This study evaluated the influence of surface treatments of resin composite substrate on the fatigue behavior of adhesively cemented lithium disilicate glass-ceramic simplified restorations. CAD/CAM lithium disilicate ceramic blocks were shaped into discs (N = 60, Ø = 10 mm; thickness = 1.0 mm). Resin composite discs (N = 60, Ø = 10 mm, thickness = 2 mm) were allocated into four groups considering the "surface treatment" factor: Ctrl - no surface treatment; Bur - grinding with coarse diamond bur (#3101G, KG Sorensen); PA - etching with 37% phosphoric acid (15 s); AA - air abrasion with alumina particles (45 μm, 10 mm distance, 2.8 bars, 10 s). The surface topography, the roughness, the fractal dimension (estimated by the box-counting method) and the contact angle analyses were performed after the surface treatments. The lithium disilicate discs were etched (5% hydrofluoric acid, 20 s), silanized and adhesively cemented (Multilink N, Ivoclar Vivadent) on the resin composite discs. The samples (bonded restoration set) were subjected to a step-stress fatigue test at 20 Hz, 10,000 cycles/step with a step-size of 100 N applied on the ceramic surface, having ceramic up and resin composite down. Fractographic analysis was performed. The fatigue data (Fatigue Failure Load - FFL; and Cycles for Failure - CFF) were analyzed by Kaplan Meier with Mantel-Cox log-rank post-hoc tests (α = 0.05). No statistical difference for fatigue performance could be found among the groups (FFL means: 820-867 N; CFF means: 53,195-61,090 cycles). The bur group showed higher surface roughness and contact angle values. The PA group has the highest average fractal dimension. Therefore, the resin composite surface treatment induces topographical changes, however, it has no effect on the fatigue behavior of lithium disilicate restorations.
Collapse
Affiliation(s)
- Renan Vaz Machry
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Ana Carolina Cadore-Rodrigues
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Maria Gabriela Packaeser
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Ezequiel Lorenzett
- Post-Graduate Program in Physics, Physics Department, Federal University of Santa Maria, Brazil.
| | | | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Faculty of Odontology, Federal University of Santa Maria, Brazil.
| |
Collapse
|
31
|
The Influence of Different Surface Cleansing Agents on Shear Bond Strength of Contaminated Lithium Disilicate Ceramic: An In Vitro Study. Int J Dent 2021; 2021:7112400. [PMID: 34422055 PMCID: PMC8373498 DOI: 10.1155/2021/7112400] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 07/27/2021] [Indexed: 11/18/2022] Open
Abstract
Materials and Methods Seventy LDS specimens were randomly divided into seven groups. The first group was noncontaminated surface (PC). The six other groups were contaminated with the saliva and silicone disclosing medium and treated with no surface cleansing agent (NC); phosphoric acid (PO); Ivoclean (IV); sodium hydroxide solution (NA); Restorative Cleansing Agent (RC); and hydrofluoric acid (HF). Then, LDS specimens were cementated with Panavia V5 to resin composite rod. Each specimen was subjected to an SBS test. The modes of failure was inspected under light microscope. The surface element of each group was examined by SEM-EDS. Results The results were analyzed with one-way ANOVA and Tamhane's T2. The mean SBS value of NC was significantly lower than others (p < 0.05), and HF was significantly higher than others (p < 0.05). However, PC, PO, IV, NA, and RC were not significantly different from each other (p > 0.05). The mode of failure was mostly adhesive failure in every group. The surface showed similar amount of elements in every group. Conclusions The SBS of LDS was reduced by saliva and silicone disclosing medium contamination which can be restored using acid- and alkaline-based surface cleansing agents before the cementation procedure.
Collapse
|
32
|
Memon AR, Li J, Egger J, Chen X. A review on patient-specific facial and cranial implant design using Artificial Intelligence (AI) techniques. Expert Rev Med Devices 2021; 18:985-994. [PMID: 34404280 DOI: 10.1080/17434440.2021.1969914] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
INTRODUCTION Researchers and engineers have found their importance in healthcare industry including recent updates in patient-specific implant (PSI) design. CAD/CAM technology plays an important role in the design and development of Artificial Intelligence (AI) based implants.The across the globe have their interest focused on the design and manufacturing of AI-based implants in everyday professional use can decrease the cost, improve patient's health and increase efficiency, and thus many implant designers and manufacturers practice. AREAS COVERED The focus of this study has been to manufacture smart devices that can make contact with the world as normal people do, understand their language, and learn to improve from real-life examples. Machine learning can be guided using a heavy amount of data sets and algorithms that can improve its ability to learn to perform the task. In this review, artificial intelligence (AI), deep learning, and machine-learning techniques are studied in the design of biomedical implants. EXPERT OPINION The main purpose of this article was to highlight important AI techniques to design PSIs. These are the automatic techniques to help designers to design patient-specific implants using AI algorithms such as deep learning, machine learning, and some other automatic methods.
Collapse
Affiliation(s)
- Afaque Rafique Memon
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Institute of Bio-medical Manufacturing and Life Quality Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianning Li
- Faculty of Computer Science and Biomedical Engineering, Institute of Computer Graphics and Vision, Graz University of Technology, Graz, Austria.,The Laboratory of Computer Algorithm for Medicine, Medical University of Graz, Graz, Austria.,Department of Neurosurgery, Medical University of Graz, Graz, Austria
| | - Jan Egger
- Faculty of Computer Science and Biomedical Engineering, Institute of Computer Graphics and Vision, Graz University of Technology, Graz, Austria.,The Laboratory of Computer Algorithm for Medicine, Medical University of Graz, Graz, Austria.,Department of Neurosurgery, Medical University of Graz, Graz, Austria.,Department of Oral and Maxillofacial Surgery, Medical University of Graz, Graz, Austria
| | - Xiaojun Chen
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Institute of Bio-medical Manufacturing and Life Quality Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
33
|
Nascimento AR, Mantovani MB, Mendonça LC, Vesselovcz J, Pacheco RR, Pini NP, Sundfeld D. Two-Year Follow-Up of Self-Etching Ceramic Primer as Surface Treatment for Feldspathic Veneers: A Clinical Case Review. Oper Dent 2021; 46:126-135. [PMID: 34192329 DOI: 10.2341/20-036-t] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/22/2020] [Indexed: 11/23/2022]
Abstract
The two-step approach of applying hydrofluoric acid followed by silane is deemed the goldstandard surface treatment protocol before bonding to glass ceramics. Given hydrofluoric acid is a toxic conditioning agent and with the intention to simplify this step, the dental company Ivoclar Vivadent (Schaan, Lietchtenstein) released a self-etching ceramic primer, Monobond Etch & Prime in 2015, claiming that hydrofluoric acid and silane application would no longer be required prior to luting glass ceramics. Therefore, this clinical case report and retrospective analysis describes the replacement of unsatisfactory anterior veneers due to clinical failures for new feldspathic glass ceramic veneers, using the aforementioned self-etching ceramic primer. After two years, feldspathic glass ceramics presented satisfying clinical performance with absence of debonding, tooth sensitivity, recurrent carious lesions, or marginal infiltration.
Collapse
|
34
|
Effect of Different Surface Treatments of Lithium Disilicate on the Adhesive Properties of Resin Cements. MATERIALS 2021; 14:ma14123302. [PMID: 34203752 PMCID: PMC8232589 DOI: 10.3390/ma14123302] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 06/08/2021] [Accepted: 06/11/2021] [Indexed: 01/30/2023]
Abstract
The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF −90 s group (17.71 MPa), while the lowest values were observed in the 5% HF −20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as β (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.
Collapse
|
35
|
Brescansin FN, Prochnow C, Guilardi LF, Kleverlaan CJ, Bacchi A, Valandro LF, Pereira GKR. Effect of different surface treatments on optical, colorimetric, and surface characteristics of a lithium disilicate glass-ceramic. J ESTHET RESTOR DENT 2021; 33:1017-1028. [PMID: 34105868 DOI: 10.1111/jerd.12793] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 04/19/2021] [Accepted: 05/25/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate the effect of surface treatments on optical, colorimetric, and surface characteristics of lithium disilicate glass-ceramic. MATERIALS AND METHODS Specimens (n = 5, IPS e.max CAD) were randomly allocated to the following treatments: mirror-polished: SiC papers; as-cut: mimicking CAD-CAM milling; ground: 90-120 μm-grit diamond bur; ground polished: ground, finished (46-30 μm-grit diamond bur), polished (diamond cups, brush and diamond paste); ground glazed: ground, glazed; ground polished glazed: association of methods. CIELAB color coordinates were obtained by a spectrophotometer. CIEDE2000 color differences (ΔE00 ) and the translucency parameter (TP00 ) were calculated. Light transmittance was assessed with a colorimeter. Surface characteristics (topography and roughness) were analyzed. Statistical differences for each condition and outcome were detected using one-way ANOVA with Tukey's post-hoc test (α = 0.05). RESULTS TP00 data show statistical reduction after grinding (p < 0.05), which was only restored with polishing (solely or with glazing). ΔE00 shows that grinding results in perceptible variations in color (above 0.81), which were restored after all post-processing protocols (exception to only glaze application in contact with a black background). Light transmittance data corroborated such performance. Polishing and glazing reduced roughness and improved surface topography. CONCLUSION Grinding statistically increased roughness, reduced translucency, light transmittance through the ceramic, and resulted on color differences. On contrary, polishing (followed or not by glazing) reduced roughness and enhanced ceramic translucency and light transmittance. Glaze also reduced roughness, but it still presented reduced translucency. The positioning (facing up or down) of the ceramic treated surface influenced the considered outcomes. CLINICAL SIGNIFICANCE Grinding with diamond burs results in a deleterious impact to the optical, colorimetric and surface characteristics of lithium disilicate ceramic. Thus, polishing (followed or not by glazing) is recommended for optical and topographical enhancements when lithium disilicate monolithic restorations require occlusal adjustments.
Collapse
Affiliation(s)
| | - Catina Prochnow
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - Luís Felipe Guilardi
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Ataís Bacchi
- MSciD Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| |
Collapse
|
36
|
Pilecco RO, Dalla-Nora F, Guilardi LF, Pereira GKR, de Andrade GS, de Melo RM, Valandro LF, Rippe MP. In-lab simulation of CAD/CAM milling of lithium disilicate glass-ceramic specimens: Effect on the fatigue behavior of the bonded ceramic. J Mech Behav Biomed Mater 2021; 121:104604. [PMID: 34087550 DOI: 10.1016/j.jmbbm.2021.104604] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/11/2021] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
The aim of this study was to evaluate the effect of in-lab simulation procedures performed on a lithium disilicate ceramic luted to a dentin-analogue material regarding the fatigue performance and topographic changes. Lithium disilicate ceramic (IPS e.max CAD) discs (Ø = 13.5 mm and 1.5 mm of thickness) were produced in different ways: milled in a CAD/CAM system (CAD/CAM - control group); mirror-polished (POL group); produced in-lab and ground with #60 silicon carbide paper (SiC group); with #60 wood sandpaper (WS group); with a fine diamond bur (DB group); or with a CAD/CAM bur adapted in a handpiece with a custom mandrel (MANDREL group). The ceramic discs were adhesively luted (Multilink N) onto dentin analogue discs (Ø = 12 mm and 2 mm of thickness) and fatigue testing (n = 19 discs) was performed by step-stress methodology (initial load of 200 N; step-size of 50 N; 10,000 cycles per step; 20 Hz). Surface roughness and contact angle analysis were also performed. According to Kaplan-Meier and post-hoc Mantel-Cox (log-rank), distinct fabrication methods affected the fatigue performance of bonded glass-ceramic discs (p< 0.001). The CAD/CAM group presented the lowest fatigue failure loads (1250 N) and number of cycles for failure (185,000), while the POL groups obtained the highest results (1752 N; 284,444 cycles). The in-lab groups had intermediate values (1355 - 1526 N; 206,052 - 238,684 cycles). Polished specimens presented the lowest roughness values (Ra = 0.041 μm), while the SiC (1.604 μm), WS (1.701 μm), and MANDREL (1.867 μm) groups showed statistically similar roughness values to the CAD/CAM group (1.738 μm). Despite differences before etching, the contact angle was similar among the milled and simulated groups after etching, except for the polished group. Even with some topographic similarities, the tested in-lab simulation methods were not able to mimic the milled specimens in terms of fatigue findings, leading to distinct magnitude of overestimations of the results.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Dalla-Nora
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luís Felipe Guilardi
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
37
|
Lobo CMM, Sacorague SCMC, Silva NRD, Costa AKF, Alves LMM, Bottino MA, Özcan M, Souza RODAE, Melo RMD. Effect of glazing application side and mechanical cycling on the biaxial flexural strength and Weibull characteristics of a Y-TZP ceramic. J Appl Oral Sci 2020; 28:e20200438. [PMID: 32997088 PMCID: PMC7521420 DOI: 10.1590/1678-7757-2020-0438] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Accepted: 07/28/2020] [Indexed: 11/21/2022] Open
Abstract
Glaze application on monolithic zirconia (Y-TZP) can be a practical approach to improve the mechanical properties of this material.
Collapse
Affiliation(s)
- Carolina Machado Martinelli Lobo
- Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Ciência e Tecnologia, Departamento de Materiais Dentários e Prótese, São José dos Campos, São Paulo, Brasil
| | - Sâmia Carolina Mota Cavalcanti Sacorague
- Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Ciência e Tecnologia, Departamento de Materiais Dentários e Prótese, São José dos Campos, São Paulo, Brasil
| | - Nathalia Ramos da Silva
- Universidade Federal do Rio Grande do Norte (UFRN), Departamento de Odontologia, Natal, Rio Grande do Norte, Brasil
| | - Anna Karina Figueiredo Costa
- Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Ciência e Tecnologia, Departamento de Materiais Dentários e Prótese, São José dos Campos, São Paulo, Brasil
| | - Larissa Marcia Martins Alves
- Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Ciência e Tecnologia, Departamento de Materiais Dentários e Prótese, São José dos Campos, São Paulo, Brasil
| | - Marco Antônio Bottino
- Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Ciência e Tecnologia, Departamento de Materiais Dentários e Prótese, São José dos Campos, São Paulo, Brasil
| | - Mutlu Özcan
- University of Zurich, Center for Dental and Oral Medicine, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Zurich, Switzerland
| | | | - Renata Marques de Melo
- Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Ciência e Tecnologia, Departamento de Materiais Dentários e Prótese, São José dos Campos, São Paulo, Brasil
| |
Collapse
|
38
|
Cadore-Rodrigues AC, Machado PS, Oliveira JSD, Jahn SL, Callegari GL, Dorneles LS, Burgo TADL, Rippe MP, Rocha Pereira GK, Valandro LF. Fatigue performance of fully-stabilized zirconia polycrystals monolithic restorations: The effects of surface treatments at the bonding surface. J Mech Behav Biomed Mater 2020; 110:103962. [PMID: 32957253 DOI: 10.1016/j.jmbbm.2020.103962] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 10/23/2022]
Abstract
This study evaluated the distinct conditioning effect of the intaglio surface of bonded fully-stabilized zirconia (FSZ) simplified restorations on the mechanical fatigue behavior of the set prior to and after aging. Ceramic disc shaped specimens (Ø= 10 mm and 1 mm thick) were randomly allocated into 14 groups considering: "surface treatments" (Ctrl: no-treatment; PM: universal primer; GLZ: low-fusing porcelain glaze; SNF: 5 nm SiO2 nanofilm deposition; AlOx: air-abrasion with aluminum oxide; SiC: air-abrasion with silica-coated aluminum oxide; 7%Si: air-abrasion with 7% silica-coated aluminum oxide); and "aging" (baseline: 24 h at 37 °C in water; or aged: 90 days at 37 °C in water + 12,000 thermal cycles). The discs were treated, luted with resin cement onto the dentin analog, subjected to aging or not, and then tested under a step-stress fatigue test at 20 Hz, 10,000 cycles/step, step-size of 100N starting at 200N, and proceeding until failure detection. Fractographic, topographic, surface roughness, contact angle, and atomic force microscopy analyzes were performed. The surface treatments at baseline led to statistically similar fatigue failure loads (953N-1313N), except for GLZ (1313N), which was significantly higher than 7%Si (953 N). Meanwhile, Ctrl had 40% pre-test failures (debonding) after aging, and therefore the worst fatigue performance (notable decrease in fatigue results), while all the other groups presented superior and statistically similar fatigue behavior (973-1271N). In fact, when considering baseline Vs aging conditions, stable fatigue results could only be noted when using surface treatments. In conclusion, internal surface treatments of FSZ ceramic restorations are mandatory for fatigue behavior stability after aging the restorative set, while non-treatment induced unstable results.
Collapse
Affiliation(s)
| | - Pablo Soares Machado
- Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | - Sérgio Luiz Jahn
- Chemical Engineering, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | | | | | - Marilia Pivetta Rippe
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | - Luiz Felipe Valandro
- Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
39
|
Step-stress vs. staircase fatigue tests to evaluate the effect of intaglio adjustment on the fatigue behavior of simplified lithium disilicate glass-ceramic restorations. J Mech Behav Biomed Mater 2020; 113:104091. [PMID: 33032009 DOI: 10.1016/j.jmbbm.2020.104091] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 09/05/2020] [Accepted: 09/14/2020] [Indexed: 11/24/2022]
Abstract
The aim of the study was to compare the outcomes for the fatigue mechanical behavior of bonded simplified lithium disilicate restorations, with and without an internal adjustment by grinding with diamond bur in running two fatigue tests: Staircase and Step-stress testing approaches. Ceramic discs (IPS e.max CAD) were prepared (Ø = 10 mm; thickness = 1.0 mm), submitted to an in-lab simulation of CAD/CAM milling (#60 SiC paper) and allocated into 2 groups according to the internal adjustment by grinding of the cementation surface: no adjustment (CTRL); or grinding with a coarse diamond bur (GR). Adhesive cementation (Multilink N) was performed onto epoxy resin discs (Ø = 10 mm; thickness = 2 mm) after ceramic/epoxy surface treatments. The cemented assemblies of each group were randomly assigned into 2 subgroups considering two fatigue tests (n = 15): Staircase - SC (250,000 cycles; 20 Hz), or Step-stress - SS (10,000 cycles per step; 20 Hz). Roughness, topographic and fractographic analyses were additionally performed. Statistical analyses were carried out using the Dixon and Mood method for Staircase data, and Kaplan-Meier and Mantel-Cox (log-rank) tests for Step-stress data. Ceramic restorations having its intaglio surface ground (GR group: SC test = 306.67 N; SS test = 646.67 N) presented lower fatigue failure load (FFL) values than the CTRL group (SC test = 879.28 N; SS test = 1090.00 N), regardless of the fatigue testing approach. The percentage of mean FFL decrease comparing the CTRL to GR group was higher for SC (65.1%) than the SS (40.7%) approach. However, a different total number of cycles was applied for each method. Both fatigue tests were able to detect the negative effect of internal adjustments of lithium disilicate glass-ceramic simplified restorations on their mechanical behavior. Therefore, both methods can be applied for similar evaluations (fatigue testing for ceramic restorations).
Collapse
|
40
|
González-Serrano C, Phark JH, Fuentes MV, Albaladejo A, Sánchez-Monescillo A, Duarte S, Ceballos L. Effect of a single-component ceramic conditioner on shear bond strength of precoated brackets to different CAD/CAM materials. Clin Oral Investig 2020; 25:1953-1965. [PMID: 32803444 DOI: 10.1007/s00784-020-03504-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 08/05/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To compare the shear bond strength (SBS) of the CAD/CAM material-bracket interface using three surface treatments: following manufacturers' instructions (MI), Monobond Etch & Prime (MEP) and 9.6% hydrofluoric acid plus silane (9.6% HF), after 24 h of water storage (24 h) and 10,000 cycles of thermocycling (TC). MATERIALS AND METHODS A total of 126 crowns with four identical buccal surfaces were fabricated using seven different CAD/CAM materials: CEREC Blocs unglazed (CBU), CEREC Blocs glazed (CBG), IPS Empress CAD (EMP), IPS e.max CAD (EMA), VITA SUPRINITY PC (SUP), inCoris TZI (TZI) and VITA ENAMIC (ENA). A total of 504 APC Flash-Free (APC FF)-precoated brackets were bonded applying three surface treatments: (1) MI; (2) MEP and (3) 9.6% HF. SBS was performed after 24 h and TC. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests (p < 0.05). RESULTS MEP conditioning yielded lower SBS results compared with MI and 9.6% HF for CBG (24 h and TC) and EMA (TC) materials. EMP conditioning with MEP after 24 h obtained lower SBS values compared with MI; however, after TC, SBS was similar to MI group and higher than with 9.6% HF. After TC for TZI ceramic, MI protocol (sandblasting) obtained higher SBS scores than MEP, but similar than 9.6% HF. Treatment of ENA with MI and MEP produced higher results than 9.6% HF after TC. SBS results were similar for CBU and SUP, regardless of the treatment. CONCLUSIONS Although each CAD/CAM material requires specific surface treatment to obtain the highest SBS of APC FF brackets, the treatment with MEP is a valid orthodontic alternative for most of the materials tested. TC significantly decreased SBS for most of the materials. CLINICAL RELEVANCE MEP can be considered a valid and promising product to condition most of the CAD/CAM ceramics evaluated for APC FF bracket bonding purposes, allowing a faster and safer procedure.
Collapse
Affiliation(s)
- Carlos González-Serrano
- Nursing and Stomatology Department, IDIBO Research Group, School of Health Sciences, Rey Juan Carlos University, Av. de Atenas, S/N, 28922, Alcorcón, Madrid, Spain
| | - Jin-Ho Phark
- Division of Restorative Sciences, Ostrow School of Dentistry, University of Southern California, Los Angeles, CA, USA
| | - María Victoria Fuentes
- Nursing and Stomatology Department, IDIBO Research Group, School of Health Sciences, Rey Juan Carlos University, Av. de Atenas, S/N, 28922, Alcorcón, Madrid, Spain
| | - Alberto Albaladejo
- Department of Surgery, School of Medicine, University of Salamanca, Salamanca, Spain
| | - Andrés Sánchez-Monescillo
- Division of Restorative Sciences, Ostrow School of Dentistry, University of Southern California, Los Angeles, CA, USA
| | - Sillas Duarte
- Division of Restorative Sciences, Ostrow School of Dentistry, University of Southern California, Los Angeles, CA, USA
| | - Laura Ceballos
- Nursing and Stomatology Department, IDIBO Research Group, School of Health Sciences, Rey Juan Carlos University, Av. de Atenas, S/N, 28922, Alcorcón, Madrid, Spain.
| |
Collapse
|
41
|
Alves DM, Cadore-Rodrigues AC, Prochnow C, Burgo TADL, Spazzin AO, Bacchi A, Valandro LF, Rocha Pereira GK. Fatigue performance of adhesively luted glass or polycrystalline CAD-CAM monolithic crowns. J Prosthet Dent 2020; 126:119-127. [PMID: 32636073 DOI: 10.1016/j.prosdent.2020.03.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 03/23/2020] [Accepted: 03/23/2020] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM Data comparing the fatigue performance of adhesively luted glass or polycrystalline ceramic systems for computer-aided design and computer-aided manufacturing (CAD-CAM) are scarce. PURPOSE The purpose of this in vitro study was to evaluate and compare the fatigue performance of monolithic crowns manufactured from glass or polycrystalline CAD-CAM ceramic systems adhesively luted to a dentin analog. MATERIALS AND METHODS Fifty-four pairs of standardized preparations of dentin analog (NEMA Grade G10) and simplified ceramic crowns of 1.5-mm thickness were obtained with 3 ceramic materials: lithium disilicate (LD) glass-ceramic (IPS e.max CAD); zirconia-reinforced lithium silicate (ZLS) glass-ceramic (Vita Suprinity); and translucent yttrium fully stabilized polycrystalline zirconia (Trans YZ) (Prettau Anterior). The simplified crowns (n=15) were adhesively cemented onto the preparations and subjected to step-stress fatigue test (initial load of 400 N, 20 Hz, 10 000 cycles, followed by 100-N increment steps until failure). Collected data (fatigue failure load [FFL] and cycles for failure [CFF]) were submitted to survival analysis with the Kaplan-Meier and Mantel-Cox post hoc tests (α=.05) and to Weibull analysis (Weibull modulus and its respective 95% confidence interval). Failed crowns were submitted to fractography analysis. The surface characteristics of the internal surface (roughness, fractal dimension) of additional crowns were accessed, and the occlusal cement thickness obtained in each luted system was measured. RESULTS Trans YZ crowns presented the highest values of FFL, CFF, and survival rates, followed by ZLS and LD (mean FFL: 1740 N>1187 N>987 N; mean CFF: 149 000>92 613>73 667). Weibull modulus and cement thickness were similar for all tested materials. LD presented the roughest internal surface, followed by ZLS (mean Ra: 226 nm>169 nm>93 nm). The LD and ZLS internal surfaces also showed higher fractal dimension, pointing to a more complex surface topography (mean fractal dimension: 2.242=2.238>2.147). CONCLUSIONS CAD-CAM monolithic crowns of Trans YZ show the best fatigue performance. In addition, ZLS crowns also showed better performance than LD crowns.
Collapse
Affiliation(s)
- Daniela Meira Alves
- Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Ana Carolina Cadore-Rodrigues
- PhD student, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Catina Prochnow
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Thiago Augusto de Lima Burgo
- Adjunct Professor, Department of Physics, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Aloísio Oro Spazzin
- Professor, Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Ataís Bacchi
- Professor, Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Luiz Felipe Valandro
- Professor, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
42
|
Dapieve KS, Machry RV, Pilecco RO, Kleverlaan CJ, Rocha Pereira GK, Venturini AB, Valandro LF. One-step ceramic primer as surface conditioner: Effect on the load-bearing capacity under fatigue of bonded lithium disilicate ceramic simplified restorations. J Mech Behav Biomed Mater 2020; 104:103686. [DOI: 10.1016/j.jmbbm.2020.103686] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 02/06/2020] [Accepted: 02/07/2020] [Indexed: 10/25/2022]
|
43
|
Schestatsky R, Zucuni CP, Dapieve KS, Burgo TAL, Spazzin AO, Bacchi A, Valandro LF, Pereira GKR. Microstructure, topography, surface roughness, fractal dimension, internal and marginal adaptation of pressed and milled lithium-disilicate monolithic restorations. J Prosthodont Res 2020; 64:12-19. [DOI: 10.1016/j.jpor.2019.05.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 05/16/2019] [Accepted: 05/20/2019] [Indexed: 11/28/2022]
|