1
|
Vierling L, Liu CC, Wiedemeier D, Gubler A, Schmidlin PR. Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study. Dent J (Basel) 2024; 12:136. [PMID: 38786534 PMCID: PMC11119916 DOI: 10.3390/dj12050136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/29/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024] Open
Abstract
This study investigates the impact of various instrumentation techniques on material removal and surface changes in titanium (Ti)- and zirconia (Zr) implant discs. Ti- and Zr discs were subjected to standardized experiments using various instruments including airflow, ultrasound, carbide, and diamond burs. Instrumentation was performed for 60 s with continuous automatic motion. Abrasion and changes in surface roughness were assessed using profilometry, while scanning electron microscopy was used to examine morphological changes and particle size. Carbide burs predominantly caused abrasion on Ti discs, while diamond burs caused more abrasion on Zr discs. The Ti discs were more susceptible to surface changes. However, among the materials tested, machined Zr discs treated with diamond burs produced the largest particle. In certain cases, a statistical significance (p < 0.05) was observed between the groups, while in others, there was no considerable difference among the means (p > 0.05). These results highlighted the statistical significance of our findings. These results found diverse alterations in surface characteristics of Ti- and Zr discs due to different instruments, with carbide and diamond burs causing notable effects. The findings highlight the need for a careful balance between promoting healing and minimizing harm during implantoplasty.
Collapse
Affiliation(s)
- Louisa Vierling
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Chun Ching Liu
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Daniel Wiedemeier
- Statistics Group, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland;
| | - Andrea Gubler
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| | - Patrick R. Schmidlin
- Clinic of Conservative and Preventive Dentistry, Division of Periodontology and Peri-Implant Diseases, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (L.V.); (C.C.L.); (A.G.)
| |
Collapse
|
2
|
Aliberti SM, Funk RHW, De Stefano M, Hoffmann T, Capunzo M. An epidemiological qualitative/quantitative SWOT-AHP analysis in order to highlight the positive or critical aspects of dental implants: A pilot study. Clin Exp Dent Res 2024; 10:e2836. [PMID: 38450945 PMCID: PMC10918715 DOI: 10.1002/cre2.836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 12/15/2023] [Accepted: 12/22/2023] [Indexed: 03/08/2024] Open
Abstract
OBJECTIVES In recent years, dental implants are increasing in popularity due to their high success rate, demonstrated functionality, and aesthetic treatment results. Scientific research is very active in proposing improvements in the quality and survival of implants, taking into consideration various aspects. The objective of this study was to provide a holistic epidemiologic view of the state of dental implants, using a systematic approach based on a multimethod SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis and AHP (analytical hierarchical process) qualitative-quantitative analysis to identify the characteristics that can determine their success or failure. MATERIALS AND METHODS The study used the hybrid method of SWOT-AHP. RESULTS Analysis of the results showed that among strengths, the skill of the dentist was considered the most important factor, followed by the success of dental implants in the old people; among weaknesses, bruxism and chronic diseases were highlighted; for opportunities, biomechanical behavior, in terms of good mechanical strength and good tribological resistance to chemical and physical agents in the oral cavity, were considered the most important factors; finally, among threats, medical liability and biomechanical problems had equal weight. CONCLUSIONS This study applied a multimethod SWOT-AHP approach to bring out favorable or critical evidence on the topic of dental implants. In accordance with the result of the strategic vector identified in the Twisting zone Adjustment type section, showed that implant surgery is a widespread technique but always needs improvement to increase the likelihood of success and reduce the complications that can lead to implant failure.
Collapse
Affiliation(s)
- Silvana Mirella Aliberti
- Department of Medicine, Surgery and Dentistry, “Scuola Medica Salernitana”University of SalernoSalernoItaly
| | - Richard H. W. Funk
- Institute of AnatomyTechnische Universität (TU) DresdenDresdenGermany
- Division of Preventive MedicineDresden International University (DIU)DresdenGermany
| | - Marco De Stefano
- Department of Industrial EngineeringUniversity of SalernoSalernoItaly
| | - Thomas Hoffmann
- Division of Preventive MedicineDresden International University (DIU)DresdenGermany
| | - Mario Capunzo
- Department of Medicine, Surgery and Dentistry, “Scuola Medica Salernitana”University of SalernoSalernoItaly
| |
Collapse
|
3
|
Smirnov A, Yanushevich O, Krikheli N, Solis Pinargote NW, Peretyagin P, Grigoriev S, Alou L, Sevillano D, López-Piriz R, Guitian F, Bartolomé JF. 3Y-TZP/Ta Biocermet as a Dental Material: An Analysis of the In Vitro Adherence of Streptococcus Oralis Biofilm and an In Vivo Pilot Study in Dogs. Antibiotics (Basel) 2024; 13:175. [PMID: 38391561 PMCID: PMC10886202 DOI: 10.3390/antibiotics13020175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/24/2024] Open
Abstract
The surface adhesion of bacterial cells and the in vivo biocompatibility of a new ceramic-metal composite made of zirconium dioxide and tantalum were evaluated. Within the framework of an in vitro study using the crystal violet staining and colony counting methods, a relatively similar adhesion of Streptococcus oralis to the 3Y-TZP/Ta biocermet (roughness Ra = 0.12 ± 0.04 µm) and Ti-Al6-V4 titanium alloy (Ra = 0.04 ± 0.01 µm) was found. In addition, in an in vivo preliminary study focused on the histological analysis of a series of rods implanted in the jaws of beagle dogs for a six-month period, the absence of any fibrous tissue or inflammatory reaction at the interface between the implanted 3Y-TZP/Ta biocermets and the new bone was found. Thus, it can be concluded that the developed ceramic-metal biocomposite may be a promising new material for use in dentistry.
Collapse
Affiliation(s)
- Anton Smirnov
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
| | - Oleg Yanushevich
- Scientific Department, A.I. Evdokimov Moscow State University of Medicine and Dentistry, Delegatskaya St., 20, p. 1, Moscow 127473, Russia
| | - Natella Krikheli
- Scientific Department, A.I. Evdokimov Moscow State University of Medicine and Dentistry, Delegatskaya St., 20, p. 1, Moscow 127473, Russia
| | - Nestor Washington Solis Pinargote
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
| | - Pavel Peretyagin
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
- Scientific Department, A.I. Evdokimov Moscow State University of Medicine and Dentistry, Delegatskaya St., 20, p. 1, Moscow 127473, Russia
| | - Sergey Grigoriev
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
| | - Luis Alou
- Microbiology Department, School of Medicine, Universidad Complutense, Avda. Complutense s/n, 28040 Madrid, Spain
| | - David Sevillano
- Microbiology Department, School of Medicine, Universidad Complutense, Avda. Complutense s/n, 28040 Madrid, Spain
| | - Roberto López-Piriz
- Instituto de Cirugía Oral Avanzada-ICOA, Calle de Fray Luis de León, 14, 28012 Madrid, Spain
| | - Francisco Guitian
- Instituto de Materiales, iMATUS-USC, Santiago de Compostela, Avenida do Mestre Mateo 25, 15782 La Coruña, Spain
| | - José Florindo Bartolomé
- Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), Campus de Cantoblanco, Calle Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| |
Collapse
|
4
|
Ng E, Tay JRH, Mattheos N, Bostanci N, Belibasakis GN, Seneviratne CJ. A Mapping Review of the Pathogenesis of Peri-Implantitis: The Biofilm-Mediated Inflammation and Bone Dysregulation (BIND) Hypothesis. Cells 2024; 13:315. [PMID: 38391928 PMCID: PMC10886485 DOI: 10.3390/cells13040315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 02/04/2024] [Accepted: 02/07/2024] [Indexed: 02/24/2024] Open
Abstract
This mapping review highlights the need for a new paradigm in the understanding of peri-implantitis pathogenesis. The biofilm-mediated inflammation and bone dysregulation (BIND) hypothesis is proposed, focusing on the relationship between biofilm, inflammation, and bone biology. The close interactions between immune and bone cells are discussed, with multiple stable states likely existing between clinically observable definitions of peri-implant health and peri-implantitis. The framework presented aims to explain the transition from health to disease as a staged and incremental process, where multiple factors contribute to distinct steps towards a tipping point where disease is manifested clinically. These steps might be reached in different ways in different patients and may constitute highly individualised paths. Notably, factors affecting the underlying biology are identified in the pathogenesis of peri-implantitis, highlighting that disruptions to the host-microbe homeostasis at the implant-mucosa interface may not be the sole factor. An improved understanding of disease pathogenesis will allow for intervention on multiple levels and a personalised treatment approach. Further research areas are identified, such as the use of novel biomarkers to detect changes in macrophage polarisation and activation status, and bone turnover.
Collapse
Affiliation(s)
- Ethan Ng
- Department of Restorative Dentistry, National Dental Centre Singapore, Singapore 168938, Singapore;
| | - John Rong Hao Tay
- Department of Restorative Dentistry, National Dental Centre Singapore, Singapore 168938, Singapore;
| | - Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand;
- Division of Oral Health and Periodontology, Department of Dental Medicine, Karolinska Institute, 14152 Stockholm, Sweden; (N.B.); (G.N.B.)
| | - Nagihan Bostanci
- Division of Oral Health and Periodontology, Department of Dental Medicine, Karolinska Institute, 14152 Stockholm, Sweden; (N.B.); (G.N.B.)
| | - Georgios N. Belibasakis
- Division of Oral Health and Periodontology, Department of Dental Medicine, Karolinska Institute, 14152 Stockholm, Sweden; (N.B.); (G.N.B.)
| | - Chaminda Jayampath Seneviratne
- School of Dentistry, The University of Queensland, Brisbane, QLD 4006, Australia
- School of Dentistry, Center for Oral-Facial Regeneration, Rehabilitation and Reconstruction (COR3), The University of Queensland, Brisbane, QLD 4072, Australia
- National Dental Research Institute Singapore, National Dental Centre Singapore, Singapore 168938, Singapore
| |
Collapse
|
5
|
Thu MK, Kang YS, Kwak JM, Jo YH, Han JS, Yeo ISL. Comparison between bone-implant interfaces of microtopographically modified zirconia and titanium implants. Sci Rep 2023; 13:11142. [PMID: 37429939 DOI: 10.1038/s41598-023-38432-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 07/07/2023] [Indexed: 07/12/2023] Open
Abstract
The aim of this study was to investigate the surface characteristics and evaluate the bone-implant interfaces of injection molded zirconia implants with or without surface treatment and compare them with those of conventional titanium implants. Four different zirconia and titanium implant groups (n = 14 for each group) were prepared: injection-molded zirconia implants without surface treatment (IM ZrO2); injection-molded zirconia implants with surface treatment via sandblasting (IM ZrO2-S); turned titanium implants (Ti-turned); and titanium implants with surface treatments via sandblasting with large-grit particles and acid-etching (Ti-SLA). Scanning electron microscopy, confocal laser scanning microscopy, and energy dispersive spectroscopy were used to assess the surface characteristics of the implant specimens. Eight rabbits were used, and four implants from each group were placed into the tibiae of each rabbit. Bone-to-implant contact (BIC) and bone area (BA) were measured to evaluate the bone response after 10-day and 28-day healing periods. One-way analysis of variance with Tukey's pairwise comparison was used to find any significant differences. The significance level was set at α = 0.05. Surface physical analysis showed that Ti-SLA had the highest surface roughness, followed by IM ZrO2-S, IM ZrO2, and Ti-turned. There were no statistically significant differences (p > 0.05) in BIC and BA among the different groups according to the histomorphometric analysis. This study suggests that injection-molded zirconia implants are reliable and predictable alternatives to titanium implants for future clinical applications.
Collapse
Affiliation(s)
- Myint Kyaw Thu
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Young Suk Kang
- 618th Medical Company (Dental Area Support)/Dental Health Activity-Korea, Camp Humphreys, APO, AP, 96297, USA
| | - Jeong Min Kwak
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Ye-Hyeon Jo
- Dental Research Institute, Seoul National University, Seoul, 03080, Korea
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea.
| |
Collapse
|
6
|
Kohal RJ, von Schierholz C, Nold J, Spies BC, Adolfsson E, Vach K, Burkhardt F. Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment. Clin Oral Implants Res 2023; 34:105-115. [PMID: 36444693 DOI: 10.1111/clr.14022] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 10/31/2022] [Accepted: 11/22/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To investigate the fracture strength and potential phase transformation of an injection-molded two-piece zirconia implant restored with a zirconia abutment after loading and/or aging. METHODS Thirty-two two-piece zirconia implants (4.0 mm diameter) restored with zirconia abutments were embedded according to ISO 14801 and divided into four groups (n = 8/group): Three groups were either exclusively hydrothermally treated (group HT; 85°C), dynamically loaded (group DL; 107 cycles; 98 N), or subjected to both treatments simultaneously (group DL/HT). One group remained untreated (group 0). A sample from each group was cross-sectioned and examined by scanning electron microscopy for possible crystal phase transformation. The remaining samples were then loaded to fracture in a static loading test. A one-way ANOVA was used for statistical analyses. RESULTS During dynamic loading, three implants of group DL and six implants of group DL/HT fractured at a load of 98 N. The fracture strength of group DL/HT (108 ± 141 Ncm) was significantly reduced compared to the other groups (group 0: 342 ± 36 Ncm; HT: 363 ± 49 Ncm; DL: 264 ± 198 Ncm) (p < .05). Fractures from group 0 and HT occurred at both implant and abutment level, whereas implants from group DL and DL/HT fractured only at implant level. A shallow monoclinic transformation zone of approximately 2 μm was observed following hydrothermal treatment. CONCLUSIONS Within the limitations of this study, it can be concluded that dynamic loading and the combination of loading and aging reduced the fracture strength of the implant abutment combination. Hydrothermal treatment caused a shallow transformation zone which had no influence on the fracture strength.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Christopher von Schierholz
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Julian Nold
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| | | | - Kirstin Vach
- Faculty of Medicine, Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, University of Freiburg, Freiburg, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
7
|
Sala L, Zufía J, Blasi G, Carrillo-de-Albornoz A. Clinical evaluation and patient related outcomes of one- and two-piece zirconia implants at five years of loading: A case series study. J ESTHET RESTOR DENT 2022; 35:577-585. [PMID: 36583946 DOI: 10.1111/jerd.13002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 12/04/2022] [Accepted: 12/12/2022] [Indexed: 12/31/2022]
Abstract
OBJECTIVE The objective of this study was to investigate the survival and biological and mechanical complications of one-piece and two-piece zirconia implants at five years of loading. MATERIALS AND METHODS Consecutive patients receiving zirconia implants were studied, collecting data at five years of loading on their clinical history, peri-implant health status, mechanical complications, esthetic results, and patient related outcomes. RESULTS The study included 18 patients with 29 implants. The survival rate was 86% in implant-based analysis and 78% in patient-based analysis. There were no cases of peri-implantitis, but mucositis was present in 53% of implants. A mean of 4.1 ± 0.81 mm was obtained for probing depth and 1.6 ± 0.9 mm for crestal bone loss (radiographic assessment). There were no implant fractures. Major (10%) and minor (10%) prosthesis complications were observed. The esthetic outcome was moderate to almost perfect, with a high level of patient satisfaction. No significant association was found between survival rate and the presence of mucositis around one- or two-piece implants or any other study variable. CONCLUSIONS The survival rate is low for one- and two-piece zirconia implants. Both types of implants demonstrated a low mechanical complication rate. The incidence of periimplantitis is low but mucositis is present in 50%. Patient satisfaction related to esthetics and function is moderate to high. They represent a good option for patients requiring an alternative to titanium implants. CLINICAL RELEVANCE Zirconia implants appear to be an alternative to the titanium option and may be indicated for patients requiring "metal-free" restorations.
Collapse
Affiliation(s)
- Leticia Sala
- Department of Periodontology, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Juan Zufía
- Private Practice in Madrid, Madrid, Spain
| | - Gonzalo Blasi
- Department of Periodontics, School of Dentistry, University of Maryland Baltimore, Baltimore, Maryland, USA.,Department of Periodontics, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Ana Carrillo-de-Albornoz
- Department of Periodontology, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
8
|
Sonaye SY, Bokam VK, Saini A, Nayak VV, Witek L, Coelho PG, Bhaduri SB, Bottino MC, Sikder P. Patient-specific 3D printed Poly-ether-ether-ketone (PEEK) dental implant system. J Mech Behav Biomed Mater 2022; 136:105510. [PMID: 36244326 DOI: 10.1016/j.jmbbm.2022.105510] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/29/2022] [Accepted: 10/02/2022] [Indexed: 11/06/2022]
Abstract
Fused Filament Fabrication (FFF)-based 3D printing is an efficient technique for developing medical implants, but it is not very useful in developing small yet mechanically robust design-specific fixtures such as dental implants (<15 mm). Specifically, it is challenging to 3D print robust Polyetheretherketone (PEEK) small implants due to PEEK's high melting temperature and melt viscosity. However, in this study, we efficiently utilize high-temperature FFF to develop the first-of-its-kind patient-specific robust PEEK dental implants with high print resolution. Specifically, we explore the effects of critical FFF processing conditions on the mechanical properties of the implants and subsequently determine an optimized set of processing conditions that are essential in developing durable dental implant systems. Our results indicate that the 3D printed dental implants exhibit good fatigue properties and suffice the clinical and industrial requirements for dental implants. Furthermore, we prove that the 3D printed implants exhibit adequate mechanical durability even after simulated (accelerated) aging of 30 years.
Collapse
Affiliation(s)
| | - Vijay K Bokam
- Department of Mechanical Engineering, Cleveland State University, Cleveland, OH, USA
| | - Akshay Saini
- Department of Mechanical Engineering, Cleveland State University, Cleveland, OH, USA
| | - Vasudev V Nayak
- Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA; Biomaterials Division - Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA
| | - Lukasz Witek
- Biomaterials Division - Department of Molecular Pathobiology, New York University College of Dentistry, New York, NY, USA; Department of Biomedical Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA
| | - Paulo G Coelho
- Department of Surgery, University of Miami Miller School of Medicine, Miami, FL, USA; Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Sarit B Bhaduri
- Department of Mechanical, Industrial and Manufacturing Engineering, University of Toledo, Toledo, OH, USA
| | - Marco C Bottino
- Department of Cariology, Restorative Sciences, Endodontics, School of Dentistry, University of Michigan, Ann Arbor, MI, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Prabaha Sikder
- Department of Mechanical Engineering, Cleveland State University, Cleveland, OH, USA.
| |
Collapse
|
9
|
Zhang F, Monzavi M, Li M, Čokić S, Manesh A, Nowzari H, Vleugels J, Van Meerbeek B. Fracture analysis of one/two-piece clinically failed zirconia dental implants. Dent Mater 2022; 38:1633-1647. [PMID: 36064469 DOI: 10.1016/j.dental.2022.08.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/13/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Analyzing factors that may have led to fracture of zirconia implants by macro/micro-fractography. METHODS Six one-piece and ten two-piece full-ceramic zirconia implants from two manufacturers, Z-Systems and CeraRoot, were retrieved after clinical failure. The time-to-failure ranged from 3 to 49 months. Optical and scanning electron microscopy (SEM) were used to analyze the fracture planes at the macro- and microscopic level. Treatment planning, surgical protocol, fracture-origin location and characteristic fracture features were assessed. RESULTS The fracture of all implants seemed to have been primarily due to overload in bending mode, while the fracture-initiation sites varied for the one- and two-piece implants. The fracture of all one-piece implants originated in the constriction region between two threads in the endosseous implant part. For two-piece implants, the abutment neck, internal abutment-implant connections and inner threads were found to be the main fracture-initiation sites. Surface defects at the root area for one-piece implants and damages at the abutment surface for two-piece implants were connected to the fracture origins. Importantly, the clinical failures of implants were often found to result from combined effects related to patient aspects, treatment planning/protocols, a high bending moment at the weakest link, implant-surface conditions and specific implant designs. SIGNIFICANCE This study provided information to be considered for future optimization of treatment planning and the surgical protocol for zirconia implants. Optimization of the surface conditions and the zirconia-starting powder were also suggested.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`; KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium.
| | - Mona Monzavi
- Periodontics and Ceramic Implantology (private Practice), 1401N Tustin Ave Suite #345, Santa Ana, CA 92705, USA
| | - Maoyin Li
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Stevan Čokić
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| | - Al Manesh
- Mission Dental Implant Center (private Practice), 26800 Crown Valley Pkwy Ste 425, Mission Viejo, CA 92691, USA
| | - Hessam Nowzari
- Periodontics and Implant Dentistry (private practice), 120 S Spalding Dr #201, Beverlyhills, CA 90210, USA
| | - Jef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, B-3001 Leuven, Belgium`
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, Kapucijnenvoer 7 block a, B-3000 Leuven, Belgium
| |
Collapse
|
10
|
Alfrisany NM, Somogyi-Ganss E, Tam L, Hatton BD, Sodhi RN, De Souza GM. Room-temperature atomic layer deposition of SiO2 on microcracked ZrO2 layers. J Mech Behav Biomed Mater 2022; 134:105410. [DOI: 10.1016/j.jmbbm.2022.105410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 07/28/2022] [Accepted: 08/01/2022] [Indexed: 10/15/2022]
|
11
|
Zhang F, Spies BC, Willems E, Inokoshi M, Wesemann C, Cokic SM, Hache B, Kohal RJ, Altmann B, Vleugels J, Van Meerbeek B, Rabel K. 3D printed zirconia dental implants with integrated directional surface pores combine mechanical strength with favorable osteoblast response. Acta Biomater 2022; 150:427-441. [PMID: 35902036 DOI: 10.1016/j.actbio.2022.07.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 06/25/2022] [Accepted: 07/19/2022] [Indexed: 11/01/2022]
Abstract
Dental implants need to combine mechanical strength with promoted osseointegration. Currently used subtractive manufacturing techniques require a multi-step process to obtain a rough surface topography that stimulates osseointegration. Advantageously, additive manufacturing (AM) enables direct implant shaping with unique geometries and surface topographies. In this study, zirconia implants with integrated lamellar surface topography were additively manufactured by nano-particle ink-jetting. The ISO-14801 fracture load of as-sintered implants (516±39 N) resisted fatigue in 5-55°C water thermo-cycling (631±134 N). Remarkably, simultaneous mechanical fatigue and hydrothermal aging at 90°C significantly increased the implant strength to 909±280 N due to compressive stress generated at the seamless transition of the 30-40 µm thick, rough and porous surface layer to the dense implant core. This unique surface structure induced an elongated osteoblast morphology with uniform cell orientation and allowed for osteoblast proliferation, long-term attachment and matrix mineralization. In conclusion, the developed AM zirconia implants not only provided high long-term mechanical resistance thanks to the dense core along with compressive stress induced at the transition zone, but also generated a favorable osteoblast response owing to the integrated directional surface pores. STATEMENT OF SIGNIFICANCE: : Zirconia ceramics are becoming the material of choice for metal-free dental implants, however significant efforts are required to obtain a rough/porous surface for enhanced osseointegration, along with the risk of surface delamination and/or microstructure variation. In this study, we addressed the challenge by additively manufacturing implants that seamlessly combine dense core with a porous surface layer. For the first time, a unique surface with a directional lamellar pore morphology was additively obtained. This AM implant also provided strength as strong as conventionally manufactured zirconia implants before and after long-term fatigue. Favorable osteoblast response was proved by in-vitro cell investigation. This work demonstrated the opportunity to AM fabricate novel ceramic implants that can simultaneously meet the mechanical and biological functionality requirements.
Collapse
Affiliation(s)
- Fei Zhang
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium.
| | - Benedikt C Spies
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - Evita Willems
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Masanao Inokoshi
- Tokyo Medical and Dental University, Graduate School of Medical and Dental Sciences, Department of Gerodontology and Oral Rehabilitation, Tokyo, Japan
| | - Christian Wesemann
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Berlin, Germany
| | - Stevan M Cokic
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Benedikt Hache
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; University of Freiburg, Faculty of Medicine, Research Center for Tissue Replacement, Regeneration and Neogenesis, Section of Cell biology-inspired Bone Regeneration, G.E.R.N. Freiburg, Germany
| | - Ralf J Kohal
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - Brigitte Altmann
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany; University of Freiburg, Faculty of Medicine, Research Center for Tissue Replacement, Regeneration and Neogenesis, Section of Cell biology-inspired Bone Regeneration, G.E.R.N. Freiburg, Germany
| | - Jef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry, Leuven, Belgium
| | - Kerstin Rabel
- University of Freiburg, Faculty of Medicine, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| |
Collapse
|
12
|
Atalay P, Öztaş DD. Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments. J ESTHET RESTOR DENT 2022; 34:1060-1067. [PMID: 35855644 DOI: 10.1111/jerd.12944] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE Zirconia implants are assumed to satisfy the esthetic requirements that titanium implants cannot meet, however, there are not enough studies in the literature about narrow-diameter and angled zirconia implants that can be preferred especially in the anterior region. This in vitro study aimed to evaluate the fatigue resistance and fracture strength of narrow-diameter zirconia implants with angled abutments. MATERIALS AND METHODS Forty-eight one-piece experimental zirconia implants and monolithic zirconia crowns were produced from 3-YTZP blanks. The implant diameters (3.0 or 3.7 mm) and the restoration types were determined according to three intraoral regions (upper central incisors, lower central incisors, and upper canine), and abutments were designed as straight or 15° angled. The samples were subjected to chewing simulation corresponding to 5 years of clinical performance and then the static loading test. The survival rates of groups were measured by the Kaplan-Meier log-rank test, and the fracture load values were estimated by using Kruskal-Wallis and Mann-Whitney U tests (p < 0.05). RESULTS All 3.0 mm diameter implants failed the fatigue test. The fatigue resistance of the implants with angled abutments was significantly lower than the straight abutments, and different crown designs were found to affect survival rates significantly. The fracture strengths of the surviving groups were above the maximum physiological chewing forces, and the differences were not significant. CONCLUSIONS The implant diameter, abutment angle, and restoration type have a significant effect on the fatigue behavior of zirconia implants. CLINICAL SIGNIFICANCE The fracture strengths of the one-piece zirconia implants with a 3.7 mm diameter and a 15° abutment angle are above the chewing forces for the anterior intraoral region.
Collapse
Affiliation(s)
- Pelin Atalay
- Department of Prosthodontics, Faculty of Dentistry, University of Niğde Ömer Halisdemir, Niğde, Turkey
| | - Doğan Derya Öztaş
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
13
|
Surface and bulk properties of zirconia as a function of composition and aging. J Mech Behav Biomed Mater 2021; 126:104994. [PMID: 34864575 DOI: 10.1016/j.jmbbm.2021.104994] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/18/2021] [Accepted: 11/21/2021] [Indexed: 01/08/2023]
Abstract
Yttria-stabilized zirconia (Y-SZ) materials with different levels of translucency have been used for indirect dental restorations. Y-SZ composition and microstructure are modified to improve translucency, and it is not clear how these materials respond to aging. This study evaluated the effect of hydrothermal aging (HA) performed in an autoclave on the properties of four dental Y-SZ materials with different compositions. Sintered bar-shaped specimens (14 x 4 x 2 mm) were prepared from four different zirconia-based materials (n = 40): low translucency 3 mol % Y-SZ (3Y-LT; Ceramill ZI, Amann Girrbach); high translucency 4 mol % Y-SZ (4Y-HT; Ceramill Zolid); and two high translucency 5 mol % Y-SZ (5Y-HT - Lava Esthetic, 3M; 5Y-SHT - Ceramill Zolid FX). Fully sintered specimens were exposed to HA for different times (control - 0 h, 5 h, 10 h, or 15 h at 134 °C, 2 bar pressure) and characterized for surface roughness, flexural strength (three-point bending), hardness and elastic modulus (nanoindentation), surface wettability (sessile drop technique) and crystalline content (x-ray diffraction, XRD). Data was analyzed by two-way ANOVA and Tukey HSD (p < 0.05). Zirconia composition significantly affected roughness (p = 0.016). Zirconia*aging interaction affected flexural strength (p = 0.012), surface wettability (p < 0.001), and hardness (p = 0.002). Zirconia composition (p = 0.011) and aging (p = 0.001) affected elastic modulus, while the interaction effect was not significant (p = 0.94). HA affects zirconia-based materials in different degrees. For 3Y-LT and 4Y-HT, surface and bulk properties were affected by aging to a similar extent. However, surface and bulk properties may change during clinical use as a result of prolonged degradation of Y-SZ.
Collapse
|
14
|
Burkhardt F, Spies BC, Riemer L, Adolfsson E, Doerken S, Kohal RJ. Fracture resistance and crystal phase transformation of a one- and a two-piece zirconia implant with and without simultaneous loading and aging-An in vitro study. Clin Oral Implants Res 2021; 32:1288-1298. [PMID: 34352139 DOI: 10.1111/clr.13825] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants. METHODS One-piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; n = 16) and two-piece (with separate implant abutment, 2P; wide diameter [5 mm]; n = 16) zirconia implants were embedded according to ISO 14801. A two-piece titanium-zirconium implant (Ti-Zr; 4.1 mm diameter) served as a control (n = 16). One subgroup (n = 8) of each system was simultaneously dynamically loaded (107 cycles; 98N) and hydrothermally aged (85°C, 58 days), while the other subgroup (n = 8) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses. RESULTS The fracture resistance of 1P (1,117 [SD = 38] N; loaded/aged: 1,009 [60] N), 2P (850 [36] N; loaded/aged: 799 [84] N), and Ti-Zr implants (1,338 [205] N; loaded/aged: 1,319 [247] N) was not affected significantly by loading/aging (p = .171). However, when comparing the systems, they revealed significant differences independent of loading/aging (p ≤ .001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems. CONCLUSIONS The Ti-Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading/aging had no significant impact on the fracture resistance of both zirconia implants. The wide-body 2P zirconia implant was weaker than the regular body 1P implant.
Collapse
Affiliation(s)
- Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | - Lennart Riemer
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| | | | - Sam Doerken
- Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center - University of Freiburg, Center for Dental Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
15
|
Vilor-Fernández M, García-De-La-Fuente AM, Marichalar-Mendia X, Estefanía-Fresco R, Aguirre-Zorzano LA. Single tooth restoration in the maxillary esthetic zone using a one-piece ceramic implant with 1 year of follow-up: case series. Int J Implant Dent 2021; 7:26. [PMID: 33821399 PMCID: PMC8021669 DOI: 10.1186/s40729-021-00308-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 02/24/2021] [Indexed: 11/16/2022] Open
Abstract
Background Oral implants have helped clinicians to improve the quality of life for many patients. The material of choice for dental implants currently remains titanium type IV, whose mechanical and biological properties have been proven throughout the history of implantology. Yet, this material is not exempt from complications. For these reasons, ceramic alternatives to titanium have emerged. Thus, the purpose of this study is to evaluate peri-implant hard and soft tissue stability with the use of a one-piece ceramic implant (Straumann® PURE Ceramic Implant) during 1 year of follow-up. Study design One-piece all-ceramic zirconia (ZrO2) implants were placed to replace single missing teeth in the esthetic zone. Six to 8 weeks after the procedure, the definitive prosthesis was fabricated. At the time of prosthesis, placement (T0) photographs and periapical radiographs were taken, and the following clinical parameters were recorded: probing depth (PD), plaque index (PI), bleeding on probing (BOP), suppuration on probing (SOP), distance from gingival margin to incisal edge (GM-IE), and Jemt papilla index (JPI). Follow-up appointments were scheduled at 4 (T4), 8 (T8), and 12 (T12) months, when the same parameters were recorded. In addition, plaque control was reinforced and prophylaxis was carried out. In this last appointment, a final periapical radiograph was taken to assess marginal bone loss. Results A total of 32 zirconia implants were placed in 28 patients (16 women and 12 men, aged between 34 and 67 years). The survival and success rate were 93.75%. The increase in probing depth from baseline to 12 months was 0.78 mm. Assessments of plaque index and bleeding on probing showed a slight increase throughout the study. Conclusions The results obtained with the Straumann® PURE Ceramic implants show them to exhibit very good clinical behavior. The survival rate of the implants of our pilot study was 93.75%. For these reasons, we can say that zirconia implants could be an alternative to titanium implants in the esthetic zone.
Collapse
Affiliation(s)
- Miren Vilor-Fernández
- Department of Stomatology II, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Bizkaia, Spain
| | - Ana-María García-De-La-Fuente
- Department of Stomatology II, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Bizkaia, Spain.
| | - Xabier Marichalar-Mendia
- Department of Nursing I, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Bizkaia, Spain
| | - Ruth Estefanía-Fresco
- Department of Stomatology II, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Bizkaia, Spain
| | - Luis-Antonio Aguirre-Zorzano
- Department of Stomatology II, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Bizkaia, Spain
| |
Collapse
|
16
|
Han J, Zhang F, Van Meerbeek B, Vleugels J, Braem A, Castagne S. Laser surface texturing of zirconia-based ceramics for dental applications: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 123:112034. [PMID: 33812647 DOI: 10.1016/j.msec.2021.112034] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 03/02/2021] [Accepted: 03/05/2021] [Indexed: 02/07/2023]
Abstract
Laser surface texturing is widely explored for modifying the surface topography of various materials and thereby tuning their optical, tribological, biological, and other surface properties. In dentistry, improved osseointegration has been observed with laser textured titanium dental implants in clinical trials. Due to several limitations of titanium materials, dental implants made of zirconia-based ceramics are now considered as one of the best alternatives. Laser surface texturing of zirconia dental implants is therefore attracting increasing attention. However, due to the brittle nature of zirconia, as well as the metastable tetragonal ZrO2 phase, laser texturing in the case of zirconia is more challenging than in the case of titanium. Understanding these challenges requires different fields of expertise, including laser engineering, materials science, and dentistry. Even though much progress was made within each field of expertise, a comprehensive analysis of all the related factors is still missing. This review paper provides thus an overview of the common challenges and current status on the use of lasers for surface texturing of zirconia-based ceramics for dental applications, including texturing of zirconia implants for improving osseointegration, texturing of zirconia abutments for reducing peri-implant inflammation, and texturing of zirconia restorations for improving restoration retention by bonding.
Collapse
Affiliation(s)
- Jide Han
- KU Leuven, Department of Mechanical Engineering and Flanders Make@KU Leuven-MaPS, Celestijnenlaan 300, 3001 Leuven, Belgium
| | - Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium; KU Leuven, Department of Oral Health Sciences, BIOMAT, Kapucijnenvoer 7 Block A, 3000 Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT, Kapucijnenvoer 7 Block A, 3000 Leuven, Belgium
| | - Jozef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium
| | - Annabel Braem
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium
| | - Sylvie Castagne
- KU Leuven, Department of Mechanical Engineering and Flanders Make@KU Leuven-MaPS, Celestijnenlaan 300, 3001 Leuven, Belgium.
| |
Collapse
|
17
|
Inokoshi M, Shimizubata M, Nozaki K, Takagaki T, Yoshihara K, Minakuchi S, Vleugels J, Van Meerbeek B, Zhang F. Impact of sandblasting on the flexural strength of highly translucent zirconia. J Mech Behav Biomed Mater 2020; 115:104268. [PMID: 33338964 DOI: 10.1016/j.jmbbm.2020.104268] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 12/08/2020] [Accepted: 12/10/2020] [Indexed: 11/26/2022]
Abstract
The objective of this study was to assess the influence of alumina sandblasting on the flexural strength of the latest generation of highly translucent yttria partially stabilized dental zirconia (Y-PSZ). Fully-sintered zirconia disk-shaped specimens (14.5-mm diameter; 1.2-mm thickness) of four Y-PSZ zirconia grades (KATANA HT, KATANA STML, KATANA UTML, all Kuraray Noritake; and Zpex Smile, Tosoh) were sandblasted at 0.2 MPa with 50-μm alumina (Al2O3) sand (Kulzer) or left as-sintered (control). For each zirconia grade, the yttria (Y2O3) content was determined using X-ray fluorescence (XRF). Surface roughness was assessed using 3D confocal laser microscopy. Micro-Raman spectroscopy (μ-Raman) and X-ray diffraction (XRD) were used to assess potentially induced residual stresses. Biaxial flexural strength (n = 20) was statistically compared by Weibull analysis. Focused ion beam - scanning electron microscopy (FIB/SEM) was used to observe the subsurface microstructure. Fracture surfaces after biaxial flexural strength testing were observed by SEM. KATANA UTML had the highest Y2O3 content (6 mol%), followed by KATANA STML and Zpex Smile (5 mol%), and KATANA HT (4 mol%). Al2O3-sandblasting significantly increased surface roughness of KATANA UTML and Zpex Smile. μRaman and XRD revealed the presence of residual compressive stress on all Al2O3-sandblasted surfaces. FIB/SEM revealed several sub-surface microcracks in the sandblasted specimens. Weibull analysis revealed that Al2O3-sandblasting increased the characteristic strength of KATANA HT, KATANA STML, whereas it decreased the strength of KATANA UTML. The strength enhancement after Al2O3-sandblasting of KATANA HT was the highest, followed by KATANA STML. For Zpex Smile, the influence was statistically insignificant. The impact of Al2O3-sandblasting on the Weibull modulus was controversial. The strength of zirconia after Al2O3-sandblasting is determined by the balance between microcrack formation (decreased strength) and surface compressive stress build-up (increased strength).
Collapse
Affiliation(s)
- Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
| | - Makoto Shimizubata
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kosuke Nozaki
- Department of Fixed Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tomohiro Takagaki
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University, Mizuho, Japan
| | - Kumiko Yoshihara
- National Institute of Advanced Industrial Science and Technology (AIST), Health Research Institute, Kagawa, Japan; Okayama University, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Department of Pathology & Experimental Medicine, Okayama, Japan
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Jozef Vleugels
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven, Dentistry, Leuven, Belgium
| | - Fei Zhang
- KU Leuven (University of Leuven), Department of Materials Engineering, Leuven, Belgium; KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven, Dentistry, Leuven, Belgium
| |
Collapse
|
18
|
Reliability of an injection-moulded two-piece zirconia implant with PEKK abutment after long-term thermo-mechanical loading. J Mech Behav Biomed Mater 2020; 110:103967. [PMID: 32851978 DOI: 10.1016/j.jmbbm.2020.103967] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 06/29/2020] [Accepted: 07/01/2020] [Indexed: 01/18/2023]
Abstract
Zirconia implants are appreciated in some clinical indications in light of their aesthetic appearance and good biocompatibility. The aim of this work was to evaluate the performance of a newly developed two-piece zirconia/polyether ketone ketone (PEKK) implant-abutment combination after long-term cyclic loading in a hydrothermal environment, using a new protocol adapted from two available ISO standards. Sixteen implants (n = 8/group) were embedded according to ISO 14801 and divided into two groups: implants in the Observational Group (OG) were cyclically loaded for 60 days (98 N, 10 million loading cycles, 2 Hz) in 85 °C water in a chewing simulator, while non-loaded/non-aged implants (as-received) constituted the Control Group (CG). After 4.7 million loading cycles, one OG implant fractured in the chewing simulator. The surviving implants were compared to CG implants by X-ray diffraction (XRD) to investigate potential ageing as suggested by ISO 13356, but also μ-Raman spectroscopy, Focused-Ion-Beam - Scanning-Electron-Microscopy (FIB-SEM), and load-to-fracture. Ageing was shown to have limited influence on the evaluated zirconia implant, with increased monoclinic content after loading/ageing being to a shallow transformed zone of ~2 μm at the implant surface. However, OG implants showed a significantly decreased fracture load of 751 ± 231 N (CG: 995 ± 161 N; p = .046). These values enable clinical application, but the fact that one failure was recorded during cyclic fatigue along with the significant decrease in strength after cyclic loading/ageing suggest that there may be room for further optimization of especially the PEKK abutment. Furthermore, good agreement was observed between the fracture modes of the implant that failed during the cyclic fatigue experiment and the in vivo failure of one implant during pre-clinical trials, validating the interest of the in vitro protocol used in this work to check the reliability of zirconia implant.
Collapse
|
19
|
Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, Spies BC. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E562. [PMID: 31991565 PMCID: PMC7040771 DOI: 10.3390/ma13030562] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 12/27/2022]
Abstract
Various protocols are available to preclinically assess the fracture resistance of zirconia oral implants. The objective of the present review was to determine the impact of different treatments (dynamic loading, hydrothermal aging) and implant features (e.g., material, design or manufacturing) on the fracture resistance of zirconia implants. An electronic screening of two databases (MEDLINE/Pubmed, Embase) was performed. Investigations including > 5 screw-shaped implants providing information to calculate the bending moment at the time point of static loading to fracture were considered. Data was extracted and meta-analyses were conducted using multilevel mixed-effects generalized linear models (GLMs). The Šidák method was used to correct for multiple testing. The initial search resulted in 1864 articles, and finally 19 investigations loading 731 zirconia implants to fracture were analyzed. In general, fracture resistance was affected by the implant design (1-piece > 2-piece, p = 0.004), material (alumina-toughened zirconia/ATZ > yttria-stabilized tetragonal zirconia polycrystal/Y-TZP, p = 0.002) and abutment preparation (untouched > modified/grinded, p < 0.001). In case of 2-piece implants, the amount of dynamic loading cycles prior to static loading (p < 0.001) or anatomical crown supply (p < 0.001) negatively affected the outcome. No impact was found for hydrothermal aging. Heterogeneous findings of the present review highlight the importance of thoroughly and individually evaluating the fracture resistance of every zirconia implant system prior to market release.
Collapse
Affiliation(s)
- Annalena Bethke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Felix Burkhardt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| |
Collapse
|