1
|
Juri AZ, Belli R, Lohbauer U, Ebendorff-Heidepriem H, Yin L. Edge chipping damage in lithium silicate glass-ceramics induced by conventional and ultrasonic vibration-assisted diamond machining. Dent Mater 2023:S0109-5641(23)00091-X. [PMID: 37076403 DOI: 10.1016/j.dental.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 04/21/2023]
Abstract
OBJECTIVES Diamond machining of lithium silicate glass-ceramics (LS) induces extensive edge chipping damage, detrimentally affecting LS restoration functionality and long-term performance. This study approached novel ultrasonic vibration-assisted machining of pre-crystallized and crystallized LS materials to investigate induced edge chipping damage in comparison with conventional machining. METHODS The vibration-assisted diamond machining was conducted using a five-axis ultrasonic high-speed grinding/machining machine at different vibration amplitudes while conventional machining was performed using the same machine without vibration assistance. LS microstructural characterization and phase development were performed using scanning electron microscopy (SEM) and x-ray diffraction (XRD) techniques. Machining-induced edge chipping depths, areas and morphology were also characterized using the SEM and Java-based imaging software. RESULTS All machining-induced edge chipping damages resulted from brittle fractures. The damage scales, however, depended on the material microstructures; mechanical properties associated with the fracture toughness, critical strain energy release rates, brittleness indices, and machinability indices; and ultrasonic vibration amplitudes. Pre-crystallized LS with more glass matrix and lithium metasilicate crystals yielded respective 1.8 and 1.6 times greater damage depths and specific damage areas than crystallized LS with less glass matrix and tri-crystal phases in conventional machining. Ultrasonic machining at optimized amplitudes diminished such damages by over 50 % in pre-crystallized LS and up to 13 % in crystallized LS. SIGNIFICANCE This research highlights that ultrasonic vibration assistance at optimized conditions may advance current dental CAD/CAM machining techniques by significant suppression of edge chipping damage in pre-crystallized LS.
Collapse
Affiliation(s)
- Afifah Z Juri
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide 5005, SA, Australia.
| | - Renan Belli
- Research Laboratory for Dental Biomaterials, Dental Clinic 1 - Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Ulrich Lohbauer
- Research Laboratory for Dental Biomaterials, Dental Clinic 1 - Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Heike Ebendorff-Heidepriem
- Institute for Photonics and Advanced Sensing (IPAS) and School of Physics, Chemistry and Earth Sciences, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Ling Yin
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide 5005, SA, Australia.
| |
Collapse
|
2
|
Soft machining-induced surface and edge chipping damage in pre-crystalized lithium silicate glass ceramics. J Mech Behav Biomed Mater 2022; 131:105224. [DOI: 10.1016/j.jmbbm.2022.105224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 03/28/2022] [Accepted: 04/02/2022] [Indexed: 11/19/2022]
|
3
|
Alao AR, Mohd Azhari MA. Investigation of indentation size effect and R-curve behaviour of Li 2O-SiO 2 and Li 2O-2SiO 2 glass ceramics. J Mech Behav Biomed Mater 2021; 124:104842. [PMID: 34555624 DOI: 10.1016/j.jmbbm.2021.104842] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 09/14/2021] [Accepted: 09/15/2021] [Indexed: 11/26/2022]
Abstract
Indentation size effect (ISE) and R-curve behaviour of Li2O-SiO2 and Li2O-2SiO2 glass ceramics are investigated using micro-indentation and indentation-strength (IS) techniques, respectively. Vickers micro-indentations were applied on both materials at the load of 0.10-19.6 N to determine the load influence on the measured hardness. For the IS-measured fracture toughness, the load ranged from 1.96 to 19.6 N. The hardness decreased with increasing load by 20% and 18% on Li2O-SiO2 and Li2O-2SiO2 glass ceramics, respectively, indicating the ISE behaviour on both materials. The fracture toughness increased with the load by 27% and 59% on Li2O-SiO2 and Li2O-2SiO2 glass ceramics, respectively, signifying the R-curve behaviour. The ISE behaviour of both materials was analysed using the Meyer's, Hays-Kendall (HK), proportional specimen resistance (PSR), Nix-Gao (NG), modified PSR (MPSR) and elastic plastic deformation (EPD) models while the R-curve behaviour was analysed by the fractional power law. The Meyer's index of both materials was less than 2, strongly confirming the ISE existence. The HK, PSR and NG models were only suitable to determine intrinsic Vickers hardness for Li2O-2SiO2 glass ceramic while the MPSR and EPD models were successful for both materials. The fractional power law gave higher R-curve steepness for Li2O-2SiO2 than Li2O-SiO2 glass ceramics. Also, material and brittleness indices predicted, respectively, higher quasi-plasticity and better machinability for Li2O-2SiO2 than Li2O-SiO2 glass ceramics indicating superior performance in the former to the latter. Finally, this study presents a new significant insight into the micro-mechanisms of fracture tolerance behaviour of these glass ceramics which is critical to their functional performance as structural ceramics.
Collapse
Affiliation(s)
- Abdur-Rasheed Alao
- Mechanical Engineering Programme Area, Faculty of Engineering, Universiti Teknologi, Brunei, Gadong, BE1410, Brunei Darussalam.
| | - Mohd Azmir Mohd Azhari
- Faculty of Manufacturing Engineering, Universiti Malaysia Pahang, 26600, Pekan, Pahang, Malaysia
| |
Collapse
|
4
|
Daguano JKMB, Dantas L, Soares VO, Alves MFRP, Santos CD, Zanotto ED. Optimizing the microstructure of a new machinable bioactive glass-ceramic. J Mech Behav Biomed Mater 2021; 122:104695. [PMID: 34293695 DOI: 10.1016/j.jmbbm.2021.104695] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 06/28/2021] [Accepted: 07/02/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES This study aimed to optimize the crystallization process and the microstructure of a new bioactive glass-ceramic (GC) previously developed by our research group to obtain machinable glass-ceramics. METHODS Differential scanning calorimetry (DSC) analyses were conducted to explore the characteristic temperatures and construct a semi-quantitative nucleation curve. The GC specimens were characterized by X-ray diffraction (XRD) and Rietveld refinement. Their brittleness index (B) and machinability were characterized and compared with IPS e.max-CAD®. Their Young's modulus, fracture toughness, and hardness were assessed. RESULTS We found that the maximum crystal nucleation rate temperature of this GC is ~470 °C. Treatments were designed based on the 1st DSC peak onset (570 °C), 1st peak offset (650 °C), and 2nd peak offset (705 °C) crystallization temperatures of lithium metasilicate (LS, LiSi2O3) and lithium disilicate (LS2, Li2Si2O5). Rietveld refinement indicated an increase in LS2 and a reduction in LS and amorphous phase for increased temperatures and longer treatment times. Their B values indicate good machinability compared with that of the control group based on statistical analyses. As expected, lower levels of LS2 increase the machinability regardless of the rotation speed adopted, leading to a greater depth of cut and reduced Edge Chipping Damage Depth (ECDD). CONCLUSION This bioactive GC with optimized microstructure presents high machinability. For treatment temperatures above 570 °C, the number of elongated LS2 crystals increases and decreases the amorphous phase content, which reduce the machinability of the GC, and should therefore be avoided. The best results were obtained using heat treatment at 570 °C, which produces LS crystals embedded in a glassy matrix (67%) with small contents of secondary phases.
Collapse
Affiliation(s)
- Juliana K M B Daguano
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, São Bernardo do Campo, SP, Brazil; Center for Information Technology Renato Archer, Campinas, SP, Brazil
| | - Laís Dantas
- Vitreous Materials Laboratory, Materials Engineering Department, Federal University of São Carlos, São Carlos, SP, Brazil
| | - Viviane O Soares
- Vitreous Materials Laboratory, Materials Engineering Department, Federal University of São Carlos, São Carlos, SP, Brazil
| | - Manuel F R P Alves
- Materials and Processes Laboratory, Faculty of Technology, State University of Rio de Janeiro, Resende, RJ, Brazil
| | - Claudinei Dos Santos
- Materials and Processes Laboratory, Faculty of Technology, State University of Rio de Janeiro, Resende, RJ, Brazil.
| | - Edgar D Zanotto
- Vitreous Materials Laboratory, Materials Engineering Department, Federal University of São Carlos, São Carlos, SP, Brazil
| |
Collapse
|
5
|
Pilecco RO, Dalla-Nora F, Guilardi LF, Pereira GKR, de Andrade GS, de Melo RM, Valandro LF, Rippe MP. In-lab simulation of CAD/CAM milling of lithium disilicate glass-ceramic specimens: Effect on the fatigue behavior of the bonded ceramic. J Mech Behav Biomed Mater 2021; 121:104604. [PMID: 34087550 DOI: 10.1016/j.jmbbm.2021.104604] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/11/2021] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
The aim of this study was to evaluate the effect of in-lab simulation procedures performed on a lithium disilicate ceramic luted to a dentin-analogue material regarding the fatigue performance and topographic changes. Lithium disilicate ceramic (IPS e.max CAD) discs (Ø = 13.5 mm and 1.5 mm of thickness) were produced in different ways: milled in a CAD/CAM system (CAD/CAM - control group); mirror-polished (POL group); produced in-lab and ground with #60 silicon carbide paper (SiC group); with #60 wood sandpaper (WS group); with a fine diamond bur (DB group); or with a CAD/CAM bur adapted in a handpiece with a custom mandrel (MANDREL group). The ceramic discs were adhesively luted (Multilink N) onto dentin analogue discs (Ø = 12 mm and 2 mm of thickness) and fatigue testing (n = 19 discs) was performed by step-stress methodology (initial load of 200 N; step-size of 50 N; 10,000 cycles per step; 20 Hz). Surface roughness and contact angle analysis were also performed. According to Kaplan-Meier and post-hoc Mantel-Cox (log-rank), distinct fabrication methods affected the fatigue performance of bonded glass-ceramic discs (p< 0.001). The CAD/CAM group presented the lowest fatigue failure loads (1250 N) and number of cycles for failure (185,000), while the POL groups obtained the highest results (1752 N; 284,444 cycles). The in-lab groups had intermediate values (1355 - 1526 N; 206,052 - 238,684 cycles). Polished specimens presented the lowest roughness values (Ra = 0.041 μm), while the SiC (1.604 μm), WS (1.701 μm), and MANDREL (1.867 μm) groups showed statistically similar roughness values to the CAD/CAM group (1.738 μm). Despite differences before etching, the contact angle was similar among the milled and simulated groups after etching, except for the polished group. Even with some topographic similarities, the tested in-lab simulation methods were not able to mimic the milled specimens in terms of fatigue findings, leading to distinct magnitude of overestimations of the results.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Dalla-Nora
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luís Felipe Guilardi
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
6
|
Fracture Load of CAD/CAM Fabricated Cantilever Implant-Supported Zirconia Framework: An In Vitro Study. Molecules 2021; 26:molecules26082259. [PMID: 33924733 PMCID: PMC8069778 DOI: 10.3390/molecules26082259] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 04/06/2021] [Accepted: 04/07/2021] [Indexed: 11/17/2022] Open
Abstract
The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond burs during the milling process. The present in vitro study investigated the fracture load for different cross-sectional dimensions of connector sites of implant-supported cantilever zirconia frameworks (ISCZFs) with different cantilever lengths (load point). A total of 48 ISCZFs (Cercon, Degudent; Dentsply, Deutschland, Germany) were fabricated by CAD/CAM and divided into four groups based on cantilever length and reinforcement of distal-abutment: Group A: 9 mm cantilever; Group B: 9 mm cantilever with reinforced distal-abutment; Group C: 12 mm cantilever; Group D: 12 mm cantilever with reinforced distal-abutment (n = 12). The ISCZFs were loaded using a universal testing machine for recording the fracture load. Descriptive statistics, ANOVA, and Tukey's test were used for the statistical analysis (p < 0.05). Significant variations were found between the fracture loads of the four ISCZFs (p = 0.000); Group-C and B were found with the weakest and the strongest distal cantilever frameworks with fracture load of 670.39 ± 130.96 N and 1137.86 ± 127.85 N, respectively. The mean difference of the fracture load between groups A (810.49 + 137.579 N) and B (1137.86 ± 127.85 N) and between C (670.39 ± 130.96 N) and D (914.58 + 149.635 N) was statistically significant (p = 0.000). Significant variations in the fracture load between the ISCZFs with different cantilever lengths and thicknesses of the distal abutments were found. Increasing the thickness of the distal abutment only by 0.5 mm reinforces the distal abutments by significantly increasing the fracture load of the ISCZFs. Therefore, an increase in the thickness of the distal abutments is recommended in patients seeking implant-supported distal cantilever fixed prostheses.
Collapse
|