1
|
Valente R, Mourato A, Xavier J, Sousa P, Domingues T, Tavares P, Avril S, Tomás A, Fragata J. Experimental Protocols to Test Aortic Soft Tissues: A Systematic Review. Bioengineering (Basel) 2024; 11:745. [PMID: 39199703 PMCID: PMC11351783 DOI: 10.3390/bioengineering11080745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 06/24/2024] [Accepted: 07/18/2024] [Indexed: 09/01/2024] Open
Abstract
Experimental protocols are fundamental for quantifying the mechanical behaviour of soft tissue. These data are crucial for advancing the understanding of soft tissue mechanics, developing and calibrating constitutive models, and informing the development of more accurate and predictive computational simulations and artificial intelligence tools. This paper offers a comprehensive review of experimental tests conducted on soft aortic tissues, employing the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) methodology, based on the Scopus, Web of Science, IEEE, Google Scholar and PubMed databases. This study includes a detailed overview of the test method protocols, providing insights into practical methodologies, specimen preparation and full-field measurements. The review also briefly discusses the post-processing methods applied to extract material parameters from experimental data. In particular, the results are analysed and discussed providing representative domains of stress-strain curves for both uniaxial and biaxial tests on human aortic tissue.
Collapse
Affiliation(s)
- Rodrigo Valente
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; (R.V.); (A.M.)
| | - André Mourato
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; (R.V.); (A.M.)
| | - José Xavier
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal; (R.V.); (A.M.)
- Intelligent Systems Associate Laboratory, LASI, 4800-058 Guimarães, Portugal
| | - Pedro Sousa
- INEGI, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (P.S.); (P.T.)
| | - Tiago Domingues
- INEGI, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (P.S.); (P.T.)
| | - Paulo Tavares
- INEGI, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (P.S.); (P.T.)
| | - Stéphane Avril
- Mines Saint-Etienne, University of Lyon, Inserm, Sainbiose U1059, Campus Santé Innovation, 10, rue de la Marandière, 42270 Saint-Priest-en-Jarez, France;
| | - António Tomás
- Department of Cardiothoracic Surgery, Santa Marta Hospital, Rua de Santa Marta, 1169-024 Lisboa, Portugal; (A.T.); (J.F.)
| | - José Fragata
- Department of Cardiothoracic Surgery, Santa Marta Hospital, Rua de Santa Marta, 1169-024 Lisboa, Portugal; (A.T.); (J.F.)
- Department of Surgery and Human Morphology, NOVA Medical School, Universidade NOVA de Lisboa, Campo Mártires da Pátria, 1169-056 Lisboa, Portugal
| |
Collapse
|
2
|
Alloisio M, Wolffs JJM, Gasser TC. Specimen width affects vascular tissue integrity for in-vitro characterisation. J Mech Behav Biomed Mater 2024; 154:106520. [PMID: 38569421 DOI: 10.1016/j.jmbbm.2024.106520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 12/01/2023] [Revised: 03/08/2024] [Accepted: 03/21/2024] [Indexed: 04/05/2024]
Abstract
The preparation of slender specimens for in-vitro tissue characterisation could potentially alter mechanical tissue properties. To investigate this factor, rectangular specimens were prepared from the wall of the porcine aorta for uniaxial tensile loading. Varying strip widths of 16 mm, 8 mm, and 4 mm were achieved by excising zero, one, and three cuts within the specimen along the loading direction, respectively. While specimens loaded along the vessel's circumferential direction acquired consistent tissue properties, the width of test specimens influenced the results of axially loaded tissue; vascular wall stiffness was reduced by approximately 40% in specimens with strips 4 mm wide. In addition, the cross-loading stretch was strongly influenced by specimen strip width, and fiber sliding contributed to the softening of slender tensile specimens, an outcome from finite element analysis of test specimens. We may, therefore, conclude that cutting orthogonal to the main direction of collagen fibers introduces mechanical trauma that weakens slender tensile specimens, compromising the determination of representative mechanical vessel wall properties.
Collapse
Affiliation(s)
- Marta Alloisio
- Material and Structural Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Joey J M Wolffs
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - T Christian Gasser
- Material and Structural Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden.
| |
Collapse
|
3
|
Fischer J, Heidrová A, Hermanová M, Bednařík Z, Joukal M, Burša J. Structural parameters defining distribution of collagen fiber directions in human carotid arteries. J Mech Behav Biomed Mater 2024; 153:106494. [PMID: 38507995 DOI: 10.1016/j.jmbbm.2024.106494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 01/05/2024] [Revised: 02/16/2024] [Accepted: 03/01/2024] [Indexed: 03/22/2024]
Abstract
Collagen fiber arrangement is decisive for constitutive description of anisotropic mechanical response of arterial wall. In this study, their orientation in human common carotid artery was investigated using polarized light microscopy and an automated algorithm giving more than 4·106 fiber angles per slice. In total 113 slices acquired from 18 arteries taken from 14 cadavers were used for fiber orientation in the circumferential-axial plane. All histograms were approximated with unimodal von Mises distribution to evaluate dominant direction of fibers and their concentration parameter. 10 specimens were analyzed also in circumferential-radial and axial-radial planes (2-4 slices per specimen in each plane); the portion of radially oriented fibers was found insignificant. In the circumferential-axial plane, most specimens showed a pronounced unimodal distribution with angle to circumferential direction μ = 0.7° ± 9.4° and concentration parameter b = 3.4 ± 1.9. Suitability of the unimodal fit was confirmed by high values of coefficient of determination (mean R2 = 0.97, median R2 = 0.99). Differences between media and adventitia layers were not found statistically significant. The results are directly applicable as structural parameters in the GOH constitutive model of arterial wall if the postulated two fiber families are unified into one with circumferential orientation.
Collapse
Affiliation(s)
- Jiří Fischer
- Brno University of Technology, Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, Technická 2896/2, Brno, 616 69, Czech Republic.
| | - Aneta Heidrová
- Brno University of Technology, Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, Technická 2896/2, Brno, 616 69, Czech Republic
| | - Markéta Hermanová
- 1st Department of Pathology, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Pekařská 664/53, 656 91, Brno, Czech Republic
| | - Zdeněk Bednařík
- 1st Department of Pathology, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Pekařská 664/53, 656 91, Brno, Czech Republic
| | - Marek Joukal
- Department of Anatomy, Faculty of Medicine, Masaryk University, Kamenice 126/3, 625 00, Brno, Czech Republic
| | - Jiří Burša
- Brno University of Technology, Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, Technická 2896/2, Brno, 616 69, Czech Republic
| |
Collapse
|
4
|
Bose S, Akbarzadeh Khorshidi M, Johnston RD, Watschke B, Mareena E, Lally C. Experimental testing combined with inverse-FE for mechanical characterisation of penile tissues. Acta Biomater 2024; 179:180-191. [PMID: 38494081 DOI: 10.1016/j.actbio.2024.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 12/07/2023] [Revised: 02/29/2024] [Accepted: 03/11/2024] [Indexed: 03/19/2024]
Abstract
Erectile dysfunction (ED) predominantly affects men in their 40-70s and can lead to poor quality of life. One option for ED treatment is surgical implantation of an inflatable penile prosthesis (IPP). However, they can be associated with negative outcomes including infection, migration or fibrosis. To improve outcomes, the interaction between the IPP device and surrounding tissues needs further investigation and this could be achieved using pre-clinical testbeds, but they need to be informed by extensive tissue testing. In this study, an experimental approach is adopted to characterise the mechanics of horse penile tissue and establish a testing protocol for penile tissue. The whole penis segments were tested in plate compression tests to obtain whole penis behaviour which is necessary for validation of a pre-clinical testbed, whilst tensile and compression tests were performed on individual penile tissues, namely corpus cavernosa and tunica albuginea. The second part of the paper deals with the development of a computational model employing an inverse finite element approach to estimate the material parameters of each tissue layer. These material parameters are in good agreement with the experimental results obtained from the individual tissue layers and whole organ tissue tests. This paper presents the first study proposing realistic nonlinear elastic material parameters for penile tissues and offers a validated testbed for IPPs. STATEMENT OF SIGNIFICANCE: Erectile Dysfunction (ED) affects over half the male population aged 40-70 potentially leading to poor quality of life. Patients not responding to conventional treatments of ED, are advised to use penile prostheses which can create an erection using implanted inflatable cylinders. A significant drawback of such prostheses, however, is the substantial tissue damage they can induce during their usage. Preclinical testbeds, including computational and bench-top models, could offer an efficient means of improving device designs to mitigate this damage but such testbeds require extensive knowledge of penile tissue properties. In this study, the authors determine penile tissue mechanics and apply an inverse FE approach to characterise the penile material properties required to validate preclinical models of the penis.
Collapse
Affiliation(s)
- Shirsha Bose
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland
| | - Majid Akbarzadeh Khorshidi
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland
| | - Robert D Johnston
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland
| | - Brian Watschke
- Urology, Boston Scientific Corp, Inc, Minnetonka, MN, USA
| | - Evania Mareena
- Urology, Boston Scientific Corp, Inc, Clonmel Co, Tipperary, Ireland
| | - Caitríona Lally
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland.
| |
Collapse
|
5
|
Chen H, Zhao M, Li Y, Wang Q, Xing Y, Bian C, Li J. A study on the ultimate mechanical properties of middle-aged and elderly human aorta based on uniaxial tensile test. Front Bioeng Biotechnol 2024; 12:1357056. [PMID: 38576445 PMCID: PMC10991712 DOI: 10.3389/fbioe.2024.1357056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 12/17/2023] [Accepted: 03/07/2024] [Indexed: 04/06/2024] Open
Abstract
Background The mechanical properties of the aorta are particularly important in clinical medicine and forensic science, serving as basic data for further exploration of aortic disease or injury mechanisms. Objective To study the influence of various factors (age, gender, test direction, anatomical location, and pathological characteristics) on the mechanical properties and thickness of the aorta. Methods In this study, a total of 24 aortas (age range: 54-88 years old) were collected, one hundred and seventy-four dog-bone-shaped samples were made, and then the uniaxial tensile test was run, finally, pathological grouping was performed through histological staining. Results Atherosclerotic plaques were mainly distributed near the openings of blood vessel branches. The distribution was most severe in the abdominal aorta, followed by the aortic arch. Aortic atherosclerosis was a more severe trend in the male group. In the comparison of thickness, there were no significant differences in age (over 50 years) and test direction, the average thickness of the aorta was greater in the male group than the female group and decreased progressively from the ascending aorta to the abdominal aorta. Comparing the mechanical parameters, various parameters are mainly negatively correlated with age, especially in the circumferential ascending aorta (εp "Y = -0.01402*X + 1.762, R2 = 0.6882", εt "Y = -0.01062*X + 1.250, R2 = 0.6772"); the parameters of males in the healthy group were larger, while the parameters of females were larger in atherosclerosis group; the aorta has anisotropy, the parameters in the circumferential direction were greater than those in the axial direction; the parameters of the ascending aorta were the largest in the circumferential direction, the ultimate stress [σp "1.69 (1.08,2.32)"] and ultimate elastic modulus [E2"8.28 (6.67,10.25)"] of the abdominal aorta were significantly larger in the axial direction; In the circumferential direction, the stress [σp "2.2 (1.31,3.98)", σt "0.13 (0.09,0.31)"] and ultimate elastic modulus (E2 "14.10 ± 7.21") of adaptive intimal thickening were greater than those of other groups, the strain (εp "0.82 ± 0.17", εt "0.53 ± 0.14") of pathological intimal thickening was the largest in the pathological group. Conclusion The present study systematically analyzed the influence of age, sex, test direction, anatomical site, and pathological characteristics on the biomechanical properties of the aorta, described the distribution of aortic atherosclerosis, and illustrated the characteristics of aortic thickness changes. At the same time, new insights into the grouping of pathological features were presented.
Collapse
Affiliation(s)
- Hongbing Chen
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| | - Minzhu Zhao
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| | - Yongguo Li
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| | - Qi Wang
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| | - Yu Xing
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| | - Cunhao Bian
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| | - Jianbo Li
- Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China
- Chongqing Engineering Research Center for Criminal Investigation Technology, Chongqing, China
- Chongqing Key Laboratory of Forensic Medicine, Chongqing, China
| |
Collapse
|
6
|
Gasser TC, Miller C, Polzer S, Roy J. A quarter of a century biomechanical rupture risk assessment of abdominal aortic aneurysms. Achievements, clinical relevance, and ongoing developments. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3587. [PMID: 35347895 DOI: 10.1002/cnm.3587] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Academic Contribution Register] [Received: 09/08/2021] [Revised: 01/28/2022] [Accepted: 03/03/2022] [Indexed: 05/12/2023]
Abstract
Abdominal aortic aneurysm (AAA) disease, the local enlargement of the infrarenal aorta, is a serious condition that causes many deaths, especially in men exceeding 65 years of age. Over the past quarter of a century, computational biomechanical models have been developed towards the assessment of AAA risk of rupture, technology that is now on the verge of being integrated within the clinical decision-making process. The modeling of AAA requires a holistic understanding of the clinical problem, in order to set appropriate modeling assumptions and to draw sound conclusions from the simulation results. In this article we summarize and critically discuss the proposed modeling approaches and report the outcome of clinical validation studies for a number of biomechanics-based rupture risk indices. Whilst most of the aspects concerning computational mechanics have already been settled, it is the exploration of the failure properties of the AAA wall and the acquisition of robust input data for simulations that has the greatest potential for the further improvement of this technology.
Collapse
Affiliation(s)
- T Christian Gasser
- Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden
- Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
| | - Christopher Miller
- Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Stanislav Polzer
- Department of Applied Mechanics, VSB-Technical University of Ostrava, Ostrava-Poruba, Czech Republic
| | - Joy Roy
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
- Department of Vascular Surgery, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
7
|
Methodology for estimation of undeformed thickness of arterial tissues. Sci Rep 2023; 13:2816. [PMID: 36797267 PMCID: PMC9935509 DOI: 10.1038/s41598-023-28871-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 07/22/2022] [Accepted: 01/25/2023] [Indexed: 02/18/2023] Open
Abstract
Soft tissue sample thickness measurement is one of the major sources of differences between mechanical responses published by different groups. New method for the estimation of unloaded sample thickness of soft tissues is proposed in this study. Ten 30 × 30 mm and ten 20 × 20 mm samples of porcine anterior thoracic aortas were loaded by gradually increased radial force. Their deformed thickness was then recorded in order to generate a pressure-thickness response. Next, the limit pressure to which the response can be considered linear was estimated. Line was fitted to the linear part of the curve and extrapolated towards zero pressure to estimate unloaded thickness (7 kPa fit). For comparison, data near zero pressure were fitted separately and extrapolated towards zero (Near Zero fit). The limit pressure for the linearity of the response was around 7 kPa. The Unloaded thickness for 30 × 30 mm samples was 2.68 ± 0.31 mm and 2.68 ± 0.3 mm for Near Zero fit and 7 kPa fit, respectively. The Unloaded thickness for 20 × 20 mm samples was 2.60 ± 0.35 mm and 2.59 ± 0.35 mm for Near Zero fit and 7 kPa fit, respectively. The median of thickness difference between smaller and larger samples was not found statistically different. Proposed method can estimate unloaded undeformed sample thickness quickly and reliably.
Collapse
|
8
|
Lisický O, Hrubanová A, Staffa R, Vlachovský R, Burša J. Constitutive models and failure properties of fibrous tissues of carotid artery atheroma based on their uniaxial testing. J Biomech 2021; 129:110861. [PMID: 34775341 DOI: 10.1016/j.jbiomech.2021.110861] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 06/15/2021] [Revised: 09/07/2021] [Accepted: 11/01/2021] [Indexed: 11/17/2022]
Abstract
To obtain an experimental background for the description of mechanical properties of fibrous tissues of carotid atheroma, a cohort of 141 specimens harvested from 44 patients during endarterectomies, were tested. Uniaxial stress-strain curves and ultimate stress and strain at rupture were recorded. With this cohort, the impact of the direction of load, presence of calcifications, specimen location, patient's age and sex were investigated. A significant impact of sex was revealed for the stress-strain curves and ultimate strains. The response was significantly stiffer for females than for males but, in contrast to ultimate strain, the strength was not significantly different. The differences in strength between calcified and non-calcified atheromas have reached statistical significance in the female group. At most of the analysed stress levels, the loading direction was found significant for the male cohort which was also confirmed by large differences in ultimate strains. The representative uniaxial stress-strain curves (given by median values of strains at chosen stress levels) were fitted with an isotropic hyperelastic model for different groups specified by the investigated factors while the observed differences between circumferential and longitudinal direction were captured by an anisotropic hyperelastic model. The obtained results should be valid also for the tissue of the fibrous cap, the rupture of which is to be predicted in clinics using computational modelling because it may induce arterial thrombosis and consequently a brain stroke.
Collapse
Affiliation(s)
- Ondřej Lisický
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Czech Republic.
| | - Anna Hrubanová
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Czech Republic
| | - Robert Staffa
- 2(nd) Department of Surgery, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Robert Vlachovský
- 2(nd) Department of Surgery, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Jiří Burša
- Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Czech Republic
| |
Collapse
|