Zhan X, Gao F, Yang Y, Tsai T, Wan Z, Yu Y. Effect of Insertional Direction of Pedicle Screw on Screw Loosening: A Biomechanical Study on Synthetic Bone Vertebra under a Physiology-like Load. Orthop Surg 2024; 16:1461-1472. [PMID: 38714346 PMCID: PMC11144517 DOI: 10.1111/os.14080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/06/2024] [Accepted: 04/09/2024] [Indexed: 05/09/2024] Open
Abstract
OBJECTIVES It is now understood that pedicle screw loosening at the implant-bone interface can lead to poor screw-bone interface purchase and decreased fixation stability. Previous biomechanical tests used cadaveric vertebrae and pull-out or torque loads to assess the effect of the insertional direction of pedicle screws on screw loosening. However, these tests faced challenges in matching biomechanical differences among specimens and simulating in vivo loads applied on pedicle screws. This study aimed to evaluate the effect of the insertional direction of pedicle screws on screw loosening using tension-compression-bending loads and synthetic bone vertebrae. METHODS Polyaxial pedicle screws were inserted into nine synthetic bone vertebrae in three directions (three samples per group): cranial, parallel, and caudad (-10°, 0°, +10° of the pedicle screw rod to the upper plane of the vertebra, respectively). Pedicle screws in the vertebrae were loaded using a polyethylene block connected to a material testing machine. Tension-compression-bending loads (100N-250N) with 30,000 cycles were applied to the pedicle screws, and displacements were recorded and then cycle-displacement curve was drawn based on cycle number. Micro-CT scans were performed on the vertebrae after removing the pedicle screws to obtain images of the screw hole, and the screw hole volume was measured using imaging analysis software. Direct comparison of displacements was conducted via cycle-displacement curve. Screw hole volume was analyzed using analysis of variance. The correlation between the displacement, screw hole volume and the direction of pedicle screw was assessed by Spearman correlation analysis. RESULTS The smallest displacements were observed in the caudad group, followed by the parallel and cranial groups. The caudad group had the smallest screw hole volume (p < 0.001 and p = 0.009 compared to the cranial and parallel groups, respectively), while the volume in the parallel group was greater than that in the cranial group (p = 0.003). Correlation analysis revealed that the insertional direction of the pedicle screw was associated with the displacement (p = -0.949, p < 0.001) and screw hole volume (p = -0.944, p < 0.001). CONCLUSION Strong correlations were found between the insertional direction of the pedicle screw and relevant parameters, including displacement and screw hole volume. Pedicle screw insertion in the caudad direction resulted in the least pedicle screw loosening.
Collapse
Affiliation(s)
- Xuqiang Zhan
- Department of Spine SurgeryTongji Hospital, School of Medicine, Tongji UniversityShanghaiChina
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration, Ministry of Education, Department of Spine SurgeryTongji Hospital, School of Medicine, Tongji UniversityShanghaiChina
| | - Feng Gao
- Department of Spine SurgeryTongji Hospital, School of Medicine, Tongji UniversityShanghaiChina
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration, Ministry of Education, Department of Spine SurgeryTongji Hospital, School of Medicine, Tongji UniversityShanghaiChina
- Yuyao Maternity and Child Health Care Hospital (Yuyao Second People's Hospital)ZhejiangChina
| | - Yangyang Yang
- School of Biomedical Engineering & Med‐X Research Institute, Shanghai Jiao Tong UniversityShanghaiChina
| | - Tsung‐Yuan Tsai
- School of Biomedical Engineering & Med‐X Research Institute, Shanghai Jiao Tong UniversityShanghaiChina
| | - Zongmiao Wan
- The First Affiliated Hospital of NanChang UniversityNanchangChina
| | - Yan Yu
- Department of Spine SurgeryTongji Hospital, School of Medicine, Tongji UniversityShanghaiChina
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration, Ministry of Education, Department of Spine SurgeryTongji Hospital, School of Medicine, Tongji UniversityShanghaiChina
| |
Collapse
|
2
|
Zhao J, Zhang Y, Zhan S, Zhang Q, Wang D, Peng F, Cui S, Wang B, Shi Z, He D, Liu B, Yang Z. Pedicle screw path planning for multi-level vertebral fixation. Med Phys 2024; 51:1547-1560. [PMID: 38215725 DOI: 10.1002/mp.16890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 07/28/2023] [Accepted: 08/16/2023] [Indexed: 01/14/2024] Open
Abstract
BACKGROUND For the spinal internal fixation procedures, connecting rods to the pedicle screws are commonly used in all spinal segments from the cervical to sacral spine. So far, we have only seen single vertebral screw trajectory planning methods in literatures. Joint screw placements in multi-level vertebrae with the constraint of an ipsilateral connecting rod are not considered. PURPOSE In this paper, a screw trajectory planning method that considers screw-rod joint system with both multi-level vertebral constraints and individual vertebral safety tolerance are proposed. METHODS The proposed method addresses three challenging constraints jointly for multi-level vertebral fixation with pedicle screws. First, a cylindrical screw safe passage model is suggested instead of a unique mathematical optimal trajectory for a single pedicle. Second, the flexible screw cap accessibility model is also included. Third, the connecting rod is modeled to accommodate the spine contour and support the needed gripping capacity. The retrospective clinical data of relative normal shape spines from Beijing Jishuitan hospital were used in the testing. The screw trajectories from the existing methods based on single vertebra and the proposed method based on multi-level vertebrae optimization are calculated and compared. RESULTS The results showed that the calculated screw placements by the proposed method can achieve 88% success rate without breaking the pedicle cortex and 100% in clinical class A quality (allow less than 2 mm out of the pedicle cortex) compared to 86.1% and 99.1%, respectively, with the existing methods. Expert evaluation showed that the screw path trajectories and the connecting rod calculated by the new method satisfied the clinical implantation requirements. CONCLUSIONS The new screw planning approach that seeks an overall optimization for multi-level vertebral fixation is feasible and more advantageous for clinical use than the single vertebral approaches.
Collapse
Affiliation(s)
- Jingwei Zhao
- Spine Surgery Department, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Yunxian Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Shi Zhan
- Spine Surgery Department, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Qi Zhang
- Spine Surgery Department, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Dan Wang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Fan Peng
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Shangqi Cui
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Binbin Wang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Zhe Shi
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Da He
- Spine Surgery Department, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Bo Liu
- Spine Surgery Department, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Zhi Yang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| |
Collapse
|
3
|
Tai CL, Chen WP, Liu MY, Li YD, Tsai TT, Lai PL, Hsieh MK. Biomechanical comparison of pedicle screw fixation strength among three different screw trajectories using single vertebrae and one-level functional spinal unit. Front Bioeng Biotechnol 2022; 10:1054738. [PMID: 36568298 PMCID: PMC9780459 DOI: 10.3389/fbioe.2022.1054738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 11/29/2022] [Indexed: 12/14/2022] Open
Abstract
Three key factors are responsible for the biomechanical performance of pedicle screw fixation: screw mechanical characteristics, bone quality and insertion techniques. To the best of the authors' knowledge, no study has directly compared the biomechanical performance among three trajectories, i.e., the traditional trajectory (TT), modified trajectory (MT) and cortical bone trajectory (CBT), in a porcine model. This study compared the pullout strength and insertion torque of three trajectory methods in single vertebrae, the pullout strength and fixation stiffness including flexion, extension, and lateral bending in a one-level instrumented functional spinal unit (FSU) that mimics the in vivo configuration were clarified. A total of 18 single vertebrae and 18 FSUs were randomly assigned into three screw insertion methods (n = 6 in each trajectory group). In the TT group, the screw converged from its entry point, passed completely inside the pedicle, was parallel to the superior endplate, was located in the superior third of the vertebral body and reached to at least the anterior third of the vertebral body. In the MT group, the convergent angle was similar to that of the TT method but directed caudally to the anterior inferior margin of the vertebral body. The results of insertion torque and pullout strength in single vertebrae were analyzed; in addition, the stiffness and pullout strength in the one-level FSU were also investigated. This study demonstrated that, in single vertebrae, the insertion torque was significantly higher in CBT groups than in TT and MT groups (p < 0.05). The maximal pullout strength was significantly higher in MT groups than in TT and CBT groups (p < 0.05). There was no significant difference in stiffness in the three motions among all groups. The maximal pullout strength in FSUs of MT and CBT groups were significantly higher than the TT groups (p < 0.05). We concluded that either MT or CBT provides better biomechanical performance than TT in single vertebrae or FSUs. The lack of significance of stiffness in FSUs among three methods suggested that MT or CBT could be a reasonable alternative to TT if the traditional trajectory was not feasible.
Collapse
Affiliation(s)
- Ching-Lung Tai
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan,Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Weng-Pin Chen
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan
| | - Mu-Yi Liu
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Yun-Da Li
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan,Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Tsung-Ting Tsai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Po-Liang Lai
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Ming-Kai Hsieh
- Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan,*Correspondence: Ming-Kai Hsieh,
| |
Collapse
|
4
|
Optimization of Spinal Reconstructions for Thoracolumbar Burst Fractures to Prevent Proximal Junctional Complications: A Finite Element Study. Bioengineering (Basel) 2022; 9:bioengineering9100491. [DOI: 10.3390/bioengineering9100491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/17/2022] [Accepted: 09/19/2022] [Indexed: 11/16/2022] Open
Abstract
The management strategies of thoracolumbar (TL) burst fractures include posterior, anterior, and combined approaches. However, the rigid constructs pose a risk of proximal junctional failure. In this study, we aim to systemically evaluate the biomechanical performance of different TL reconstruction constructs using finite element analysis. Furthermore, we investigate the motion and the stress on the proximal junctional level adjacent to the constructs. We used a T10-L3 finite element model and simulated L1 burst fracture. Reconstruction with posterior instrumentation (PI) alone (U2L2 and U1L1+(intermediate screw) and three-column spinal reconstruction (TCSR) constructs (U1L1+PMMA and U1L1+Cage) were compared. Long-segment PI resulted in greater global motion reduction compared to constructs with short-segment PI. TCSR constructs provided better stabilization in L1 compared to PI alone. Decreased intradiscal and intravertebral pressure in the proximal level were observed in U1L1+IS, U1L1+PMMA, and U1L1+Cage compared to U2L2. The stress and strain energy of the pedicle screws decreased when anterior reconstruction was performed in addition to PI. We showed that TCSR with anterior reconstruction and SSPI provided sufficient immobilization while offering additional advantages in the preservation of physiological motion, the decreased burden on the proximal junctional level, and lower risk of implant failure.
Collapse
|
5
|
López I, Echeverry-Mejía J, Ortiz JG, Juha M. Selection methodology of femoral stems under fatigue loading conditions. Comput Methods Biomech Biomed Engin 2022:1-10. [PMID: 36106657 DOI: 10.1080/10255842.2022.2112186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The endurance properties of a femoral stem under fatigue loading must be known and the methodology proposed in this work provides the mathematical tools for designers of femoral stems and orthopedic surgeons to select the adequate material and femoral stem design with a new graph that condensate the information in an easy to use selection process. Initially, the theoretical and computational development of the fatigue analysis provides comparable results with an average error of 8.3%. And the formulated methodology with the aim of selecting the mechanical device with the best fatigue performance with an average error of 8.7%.
Collapse
Affiliation(s)
- Iván López
- Doctorado en ingeniería, Facultad de Ingeniería, Universidad de La Sabana, Chía, Cundinamarca, Colombia
- Human Centered Design (HCD) research group, Universidad de La Sabana, Chía, Cundinamarca, Colombia
| | | | | | - Mario Juha
- Energy, Materials and Environment (GEMA) research group, Universidad de La Sabana, Chía, Cundinamarca, Colombia
| |
Collapse
|
6
|
Ji Y, Zhang Q, Song Y, Hu Q, Fekete G, Baker JS, Gu Y. Biomechanical characteristics of 2 different posterior fixation methods of bilateral pedicle screws: A finite element analysis. Medicine (Baltimore) 2022; 101:e30419. [PMID: 36086784 PMCID: PMC10980486 DOI: 10.1097/md.0000000000030419] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 07/27/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND To explore the biomechanical characteristics of 2 posterior bilateral pedicle screw fixation methods using finite element analysis. METHODS A normal L3-5 finite element model was established. Based on the verification of its effectiveness, 2 different posterior internal fixation methods were simulated: bilateral pedicle screws (model A) were placed in the L3 and L5 vertebral bodies, and bilateral pedicle screws (model B) were placed in the L3, L4, and L5 vertebral bodies. The stability and stress differences of intervertebral discs, endplates, screws, and rods between models were compared. RESULTS Compared with the normal model, the maximum stress of the range of motion, intervertebral disc, and endplate of the 2 models decreased significantly. Under the 6 working conditions, the 2 internal fixation methods have similar effects on the stress of the endplate and intervertebral disc, but the maximum stress of the screws and rods of model B is smaller than that of model A. CONCLUSIONS Based on these results, it was found that bilateral pedicle screw fixation in 2 vertebrae L3 and L5 can achieve similar stability as bilateral pedicle screw fixation in 3 vertebrae L3, L4, and L5. However, the maximum stress of the screw and rod in model B is less than that in model A, so this internal fixation method can effectively reduce the risk of fracture. The 3-dimensional finite element model established in this study is in line with the biomechanical characteristics of the spine and can be used for further studies on spinal column biomechanics. This information can serve as a reference for clinicians for surgical selection.
Collapse
Affiliation(s)
- Yulei Ji
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Qiaolin Zhang
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Yang Song
- Faculty of Sports Science, Ningbo University, Ningbo, China
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
| | - Qiuli Hu
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Gusztáv Fekete
- Savaria Institute of Technology, Eötvös Loránd University, Szombathely, Hungary
| | - Julien S. Baker
- Department of Sport and Physical Education, Hong Kong Baptist University, Hong Kong, China
| | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo, China
| |
Collapse
|
7
|
Song F, Feng W, Yang D, Li G, Iqbal K, Liu Y, Yang H. A Novel Screw Modeling Approach to Study the Effects of Screw Parameters on Pullout Strength. J Biomech Eng 2022; 145:1143328. [PMID: 35864784 DOI: 10.1115/1.4055035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Indexed: 11/08/2022]
Abstract
Screw loosening remains a prominent problem for osteoporotic patients undergoing pedicle screw fixation surgeries and is affected by screw parameters (e.g., diameter, pitch and thread angle). However, the individual and interactive effects of these parameters on screw fixation are not fully understood. Furthermore, current finite element modeling of an threaded screw is less computationally efficient. To address these issues, we (1) explored a novel "simulated threaded screw" approach (virtual threads assigned to the contact elements of a simplified screw) and compared its performance with threaded and simplified screws, and (2) examined with this approach the individual and interactive effects of altering screw diameter (5.5-6.5 mm), pitch (1-2 mm) and half-thread angle (20-30°) on pullout strength of normal vertebrae. Results demonstrated that the "simulated threaded screw" approach equivalently predicted pullout strength compared to the "threaded screw" approach (R2 = 0.99, slope = 1). We further found that the pullout strength was most sensitive to the change in screw diameter, followed by thread angle, pitch and interactions of diameter*pitch or diameter*angle. In conclusion, the "simulated threaded screw" approach can achieve the same predictive capability compared to threaded modeling of the screw. The current findings may serve as useful references for planning of screw parameters, so as to improve the complication of screw loosening.
Collapse
Affiliation(s)
- Fei Song
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| | - Wentian Feng
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| | - Dongyue Yang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| | - Guanghui Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| | - Kamran Iqbal
- Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| | - Yuxuan Liu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| | - Haisheng Yang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China
| |
Collapse
|
8
|
Predicting pullout strength of pedicle screws in broken bones from X-ray images. J Mech Behav Biomed Mater 2022; 134:105366. [PMID: 35870229 DOI: 10.1016/j.jmbbm.2022.105366] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/23/2022] [Accepted: 07/09/2022] [Indexed: 12/19/2022]
Abstract
Pedicle screw fixation is one of the most common procedures used in spinal fusion surgery. The screw loosening is a major concern, which may be caused by broken pedicles. In vitro pullout tests or insertion torque are the main approaches for assessing the stability of the screw; however, direct evidence was lacking for clinical human spines. Here, we aim to provide a model that can predict the pullout strengths of pedicle screws in various pedicle conditions from X-ray images. A weighted embedded bone volume (EBV) model is proposed for pullout strengths prediction by considering the bone heterogeneity and confinement of the screw. We showed that the pullout strength is proportional to the EBV for homogeneous bone and the weighted EBV for layered composite bone. The proposed weighted EBV model is validated with in vitro Sawbones® pullout experiments. The results show that the model has better accuracy than the simple EBV model, with a coefficient of determination of 0.94. The proposed weighted EBV model can help assess the stability of a pedicle screw in a broken pedicle by simply examining 2D X-ray images.
Collapse
|
9
|
Osteolytic vs. Osteoblastic Metastatic Lesion: Computational Modeling of the Mechanical Behavior in the Human Vertebra after Screws Fixation Procedure. J Clin Med 2022; 11:jcm11102850. [PMID: 35628977 PMCID: PMC9144065 DOI: 10.3390/jcm11102850] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 05/11/2022] [Accepted: 05/16/2022] [Indexed: 12/27/2022] Open
Abstract
Metastatic lesions compromise the mechanical integrity of vertebrae, increasing the fracture risk. Screw fixation is usually performed to guarantee spinal stability and prevent dramatic fracture events. Accordingly, predicting the overall mechanical response in such conditions is critical to planning and optimizing surgical treatment. This work proposes an image-based finite element computational approach describing the mechanical behavior of a patient-specific instrumented metastatic vertebra by assessing the effect of lesion size, location, type, and shape on the fracture load and fracture patterns under physiological loading conditions. A specific constitutive model for metastasis is integrated to account for the effect of the diseased tissue on the bone material properties. Computational results demonstrate that size, location, and type of metastasis significantly affect the overall vertebral mechanical response and suggest a better way to account for these parameters in estimating the fracture risk. Combining multiple osteolytic lesions to account for the irregular shape of the overall metastatic tissue does not significantly affect the vertebra fracture load. In addition, the combination of loading mode and metastasis type is shown for the first time as a critical modeling parameter in determining fracture risk. The proposed computational approach moves toward defining a clinically integrated tool to improve the management of metastatic vertebrae and quantitatively evaluate fracture risk.
Collapse
|
10
|
Bakhshyani M, Jallab M, Aarabi M, Ghaffari M. Development of a high-performance PVA/DOPA bone adhesive incorporated with bioactive glass and hydroxyapatite particles for highly comminuted bone fractures. POLYM-PLAST TECH MAT 2022. [DOI: 10.1080/25740881.2021.1995419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Affiliation(s)
- Mobina Bakhshyani
- Department of Polymer Engineering, School of Engineering, Golestan University, Gorgan, Iran
| | - Mojtaba Jallab
- Department of Polymer Engineering, School of Engineering, Golestan University, Gorgan, Iran
| | - Mehdi Aarabi
- Bone, and Connective Tissue Research Center, Golestan University of Medical Sciences, Gorgan, Iran
| | - Mehdi Ghaffari
- Department of Polymer Engineering, School of Engineering, Golestan University, Gorgan, Iran
| |
Collapse
|
11
|
Wills DJ, Prasad A, Gilmer BB, Walsh WR. The thermal profile of self-tapping screws: The effect of insertion speed, power insertion, and screw geometry on heat production at the bone-screw interface. Med Eng Phys 2022; 100:103754. [DOI: 10.1016/j.medengphy.2022.103754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 11/24/2021] [Accepted: 01/05/2022] [Indexed: 10/19/2022]
|
12
|
Blázquez-Carmona P, Sanz-Herrera JA, Martínez-Vázquez FJ, Domínguez J, Reina-Romo E. Structural optimization of 3D-printed patient-specific ceramic scaffolds for in vivo bone regeneration in load-bearing defects. J Mech Behav Biomed Mater 2021; 121:104613. [PMID: 34126507 DOI: 10.1016/j.jmbbm.2021.104613] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/26/2021] [Accepted: 05/27/2021] [Indexed: 02/06/2023]
Abstract
Tissue engineering has recently gained popularity as an alternative to autografts to stimulate bone tissue regeneration through structures called scaffolds. Most of the in vivo experiments on long-bony defects use internally-stabilized generic scaffolds. Despite the wide variety of computational methods, a standardized protocol is required to optimize ceramic scaffolds for load-bearing bony defects stabilized with flexible fixations. An optimization problem was defined for applications to sheep metatarsus defects. It covers biological parameters (porosity, pore size, and the specific surface area) and mechanical constraints based on in vivo and in vitro results reported in the literature. The optimized parameters (59.30% of porosity, 5768.91 m-1 of specific surface area, and 360.80 μm of pore size) and the compressive strength of the selected structure were validated in vitro by means of tomographic images and compression tests of six 3D-printed samples. Divergences between the design and measured values of the optimized parameters, mainly due to manufacturing defects, are consistent with the previous studies. Using the mixed experimental-mathematical scaffold-design procedure described, they could be implanted in vivo with instrumented external fixators, therefore facilitating biomechanical monitoring of the regeneration process.
Collapse
Affiliation(s)
- Pablo Blázquez-Carmona
- E.T.S.I, Universidad de Sevilla, Avenida Camino de los Descubrimientos s/n, 41092, Seville, Spain.
| | | | | | - Jaime Domínguez
- E.T.S.I, Universidad de Sevilla, Avenida Camino de los Descubrimientos s/n, 41092, Seville, Spain.
| | - Esther Reina-Romo
- E.T.S.I, Universidad de Sevilla, Avenida Camino de los Descubrimientos s/n, 41092, Seville, Spain.
| |
Collapse
|
13
|
Sensale M, Vendeuvre T, Schilling C, Grupp T, Rochette M, Dall'Ara E. Patient-Specific Finite Element Models of Posterior Pedicle Screw Fixation: Effect of Screw's Size and Geometry. Front Bioeng Biotechnol 2021; 9:643154. [PMID: 33777914 PMCID: PMC7990075 DOI: 10.3389/fbioe.2021.643154] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 02/18/2021] [Indexed: 11/13/2022] Open
Abstract
Pedicle screw fixation is extensively performed to treat spine injuries or diseases and it is common for thoracolumbar fractures. Post-operative complications may arise from this surgery leading to back pain or revisions. Finite element (FE) models could be used to predict the outcomes of surgeries but should be verified when both simplified and realistic designs of screws are used. The aim of this study was to generate patient-specific Computed Tomography (CT)-based FE models of human vertebrae with two pedicle screws, verify the models, and use them to evaluate the effect of the screws' size and geometry on the mechanical properties of the screws-vertebra structure. FE models of the lumbar vertebra implanted with two pedicle screws were created from anonymized CT-scans of three patients. Compressive loads were applied to the head of the screws. The mesh size was optimized for realistic and simplified geometry of the screws with a mesh refinement study. Finally, the optimal mesh size was used to evaluate the sensitivity of the model to changes in screw's size (diameter and length) and geometry (realistic or simplified). For both simplified and realistic models, element sizes of 0.6 mm in the screw and 1.0 mm in the bone allowed to obtain relative differences of approximately 5% or lower. Changes in screw's length resulted in 4-10% differences in maximum deflection, 1-6% differences in peak stress in the screws, 10-22% differences in mean strain in the bone around the screw; changes in screw's diameter resulted in 28-36% differences in maximum deflection, 6-27% differences in peak stress in the screws, and 30-47% differences in mean strain in the bone around the screw. The maximum deflection predicted with realistic or simplified screws correlated very well (R 2 = 0.99). The peak stress in screws with realistic or simplified design correlated well (R 2 = 0.82) but simplified models underestimated the peak stress. In conclusion, the results showed that the diameter of the screw has a major role on the mechanics of the screw-vertebral structure for each patient. Simplified screws can be used to estimate the mechanical properties of the implanted vertebrae, but the systematic underestimation of the peak stress should be considered when interpreting the results from the FE analyses.
Collapse
Affiliation(s)
- Marco Sensale
- Ansys France, Lyon, France.,Department of Oncology and Metabolism, Mellanby Centre for Musculoskeletal Research, University of Sheffield, Sheffield, United Kingdom.,INSIGNEO Institute for in Silico Medicine, University of Sheffield, Sheffield, United Kingdom
| | - Tanguy Vendeuvre
- Spine and Neuromodulation Functional Unit, Poitiers University Hospital, Poitiers, France.,PRISMATICS Lab (Predictive Research in Spine/Neuromodulation Management and Thoracic Innovation/Cardiac Surgery), Poitiers University Hospital, Poitiers, France
| | | | - Thomas Grupp
- Aesculap AG, Research and Development, Tuttlingen, Germany.,Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, Ludwig Maximilians University of Munich, Munich, Germany
| | | | - Enrico Dall'Ara
- Department of Oncology and Metabolism, Mellanby Centre for Musculoskeletal Research, University of Sheffield, Sheffield, United Kingdom.,INSIGNEO Institute for in Silico Medicine, University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|