1
|
Moreira PM, Carvalho GLM, de Castro Albuquerque R, André CB. Effect of hydrofluoric acid and self-etch ceramic primers on the flexural strength and fatigue resistance of glass ceramics: A systematic review and meta-analysis of in vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2024; 60:198-210. [PMID: 39027733 PMCID: PMC11254839 DOI: 10.1016/j.jdsr.2024.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 05/06/2024] [Accepted: 06/04/2024] [Indexed: 07/20/2024] Open
Abstract
This systematic review evaluated the effect of different hydrofluoric acid (HF) etching regimens and a self-etch ceramic primer (SECP) on the flexural strength (FS) and fatigue failure load (FFL) of glass-ceramic materials.The identification of relevant studies was conducted by two authors in five databases: PubMED, Scopus, Web Of Science, LILACS and Virtual Health Library (BVS) until July 2022 with no year limit. The analysis was conducted in RevMan 5.4.1 Software (Cochrane Collaboration) using Random effect model at 5 %. The risk of bias of the included studies were assessed. From the 5349 articles identified, 34 were included for quantitative analysis. Meta-analysis showed that for predominantly glassy ceramics, etching with HF 5 % had no significant impact on FS, however, HF acid etching with concentrations greater than 5 % negatively impacted FS. For lithium disilicate glass-ceramics (LDGC) HF acid etching, negatively influenced FS, while increasing the FFL. HF etching negatively affected FS of hybrid ceramics. The self-etch ceramic primer and HF acid etching showed a similar impact on FFL and FS. This meta-analysis indicates that the impact of SECP and HF acid etching on the mechanical behavior of glass ceramics is material-dependent.
Collapse
Affiliation(s)
- Paulo Matias Moreira
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | | | - Rodrigo de Castro Albuquerque
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| | - Carolina Bosso André
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil
| |
Collapse
|
2
|
Tribst JPM, Tach Q, de Kok P, Dal Piva AMDO, Kuijs RH, Kleverlaan CJ. Thickness and Substrate Effect on the Mechanical Behaviour of Direct Occlusal Veneers. Int Dent J 2023; 73:612-619. [PMID: 36509557 PMCID: PMC10509395 DOI: 10.1016/j.identj.2022.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 11/09/2022] [Indexed: 12/13/2022] Open
Abstract
PURPOSE This study aimed to evaluate the fracture resistance and stress magnitude of occlusal veneers made of conventional or flowable resin composites at different minimal thicknesses bonded on enamel or dentin. MATERIAL AND METHODS A total of 120 sound bovine incisors were flattened and used as substrates (enamel or dentin) for the restorations. The teeth were embedded into polymethyl methacrylate and allocated into 4 groups according to the resin composite (Clearfil AP-X PLT and Clearfil Majesty Flow, Kuraray Dental) and substrate. Further, the substrates were randomly subdivided in 12 groups (N = 120, n = 10) according to the occlusal veneer minimal thickness: 0.5, 1.0, or 2.0 mm. The teeth were directly restored with a standardised procedure. Then, the specimens were loaded until fracture in a universal testing machine (Instron 6022, Instron Corp.). A 3-way and a 1-way analysis of variance were used to determine significant differences for each factor. Three-dimensional finite element analysis was carried out following the in vitro boundary conditions to assess the stress magnitude in the restoration during compressive loading. RESULTS The fracture loads were recorded into initial load to failure (ILF) and fatal load to failure (FLF). Differences were found in material for ILF and FLF, leading to an overall equal good performance in fracture load and stress distribution for both materials, regardless of the substrate. Differences in thickness were apparent in both ILF and FLF. CONCLUSIONS Direct conventional and flow resin composite occlusal veneers present a promising mechanical behaviour when bonded on enamel or dentin. However, caution is advised when preparing 0.5-mm minimal thickness restorations.
Collapse
Affiliation(s)
- João Paulo M Tribst
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Qais Tach
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands; Private practice, Rotterdam, The Netherlands
| | - Paul de Kok
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Amanda Maria de O Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands.
| | - Ruud H Kuijs
- Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Cornelis J Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Alves WG, Souza LFB, Pereira GKR, Valandro LF, Kapczinski MP, Mengatto CM, Fraga S. Fit and fatigue behavior of CAD-CAM lithium disilicate crowns. J Prosthet Dent 2023; 130:241.e1-241.e8. [PMID: 37328406 DOI: 10.1016/j.prosdent.2023.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 05/19/2023] [Accepted: 05/19/2023] [Indexed: 06/18/2023]
Abstract
STATEMENT OF PROBLEM New computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate glass-ceramics have been marketed. However, information concerning their biomechanical behavior is lacking. PURPOSE The purpose of this in vitro study was to compare the fit and fatigue behavior of two recently introduced CAD-CAM lithium disilicate materials with the standard IPS e.max CAD ceramic and to investigate the effect of the thermal treatment for crystallization on crown fit. MATERIAL AND METHODS Monolithic crowns (n=15) were milled from 3 CAD-CAM lithium disilicates: IPS e.max CAD (Ivoclar AG), Rosetta SM (Hass), and T-lithium (Shenzhen Upcera Dental Technology). Marginal and internal fit were evaluated using the replica technique before and after crystallization, and the fatigue behavior of the luted crowns was evaluated by the step-stress method. One-way ANOVA and the Tukey test were used to compare fit among the materials. Fatigue failure load was evaluated by the Kaplan-Meier and Mantel-Cox tests. The effect of crystallization on fit was evaluated with the paired t test (α=.05). RESULTS Marginal fit was different between IPS e.max CAD (74 μm) and Rosetta SM (63 μm) (P=.02). T-lithium was similar to the other ceramics (68 μm) (P>.05). Occlusal internal space was similar among all materials (P=.69). Fatigue failure loads of Rosetta SM (1160 N) and T-lithium (1063 N) were similar to IPS e.max CAD (1082 N) (P>.05). The fatigue failure load of Rosetta SM was higher than that of T-lithium (P=.04). Crystallization reduced the axial internal space of all materials (P<.05) without significantly affecting marginal fit (P>.05). CONCLUSIONS The fit and fatigue behavior of Rosetta SM and T-lithium were similar to that of IPS e.max CAD. Crystallization reduced the internal space of the crowns.
Collapse
Affiliation(s)
- William Garcia Alves
- Graduate student, Department of Conservative Dentistry, School of Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Luiza Freitas Brum Souza
- Postgraduate Student, Post-Graduate Program in Dental Science, Prosthodontics Unit, Department of Restorative Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, Department of Restorative Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Luiz Felipe Valandro
- Professor, Department of Restorative Dentistry, Universidade Federal de Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Myriam Pereira Kapczinski
- Associate Professor, Department of Conservative Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Cristiane Machado Mengatto
- Associate Professor, Department of Conservative Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil
| | - Sara Fraga
- Adjunct Professor, Department of Conservative Dentistry, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, Rio Grande do Sul, Brazil.
| |
Collapse
|
4
|
Cyclic fatigue vs static loading for shear bond strength test of lithium disilicate and dentin substrates: A comparison of resin cement viscosities. Dent Mater 2022; 38:1910-1920. [DOI: 10.1016/j.dental.2022.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2022] [Revised: 09/22/2022] [Accepted: 09/22/2022] [Indexed: 11/16/2022]
|
5
|
Velho HC, da Rosa LS, Temp RW, Cocco FM, Pereira GKR, May LG, Valandro LF. Adhesive application after ceramic surface treatment is detrimental to load-bearing capacity under fatigue of a lithium disilicate glass-ceramic. J Mech Behav Biomed Mater 2022; 135:105453. [PMID: 36126505 DOI: 10.1016/j.jmbbm.2022.105453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 08/30/2022] [Accepted: 09/03/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate whether an adhesive application after surface treatment on a lithium disilicate ceramic (LD) has an influence on its load-bearing capacity under fatigue. METHODS LD discs (Ø= 10 mm; thickness= 1 mm) were allocated into 8 groups (n= 15), considering 3 factors: "ceramic surface treatment" - HF: hydrofluoric acid + universal primer application; or MEP: single-component ceramic primer; "adhesive application" - with or without; and "aging protocol" - baseline: 24 h to 7 days; or aging: 180 days of storage + 25,000 thermal cycles. The LD discs were adhesively bonded to glass fiber-reinforced epoxy resin discs (Ø= 10 mm; thickness= 2 mm) and stored according to the condition and each group. Cyclic fatigue testing (initial load= 100 N; step size= 100 N until600 N and after step size= 25 N to failure; 10,000 cycles/step; 20 Hz frequency) was performed. Fractographic and adhesive interface analyzes were also performed. The collected data were then analyzed by Kaplan Meier and Mantel-Cox tests and One-way ANOVA. RESULTS The adhesive application in the baseline condition had no influence on the load-bearing capacity under fatigue when the HF surface treatment was performed, however, adhesive application for the MEP treatment led to worse results than without it. The adhesive application in the aged condition showed worse fatigue outcomes for both treatments. All specimens presented radial cracks. MEP treatment followed by adhesive application presented the thickest luting layer. CONCLUSION The adhesive application after surface treatments of a lithium disilicate glass-ceramic is detrimental to its load-bearing capacity under fatigue when adhesively luted onto a supporting substrate.
Collapse
Affiliation(s)
- Helder Callegaro Velho
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Lucas Saldanha da Rosa
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renatta Wrasse Temp
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Maidana Cocco
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Liliana Gressler May
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|