Keating MF, Wolfe CA, Liebenberg K, Montgomery A, Porcari AM, Fleming ND, Makarov A, Eberlin LS. Data Acquisition and Intraoperative Tissue Analysis on a Mobile, Battery-Operated, Orbitrap Mass Spectrometer. Anal Chem 2024; 96:8234-8242. [PMID: 38739527 DOI: 10.1021/acs.analchem.4c00722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
Mass spectrometry has been increasingly explored in intraoperative studies as a potential technology to help guide surgical decision making. Yet, intraoperative experiments using high-performance mass spectrometry instrumentation present a unique set of operational challenges. For example, standard operating rooms are often not equipped with the electrical requirements to power a commercial mass spectrometer and are not designed to accommodate their permanent installation. These obstacles can impact progress and patient enrollment in intraoperative clinical studies because implementation of MS instrumentation becomes limited to specific operating rooms that have the required electrical connections and space. To expand our intraoperative clinical studies using the MasSpec Pen technology, we explored the feasibility of transporting and acquiring data on Orbitrap mass spectrometers operating on battery power in hospital buildings. We evaluated the effect of instrument movement including acceleration and rotational speeds on signal stability and mass accuracy by acquiring data using direct infusion electrospray ionization. Data were acquired while rolling the systems in/out of operating rooms and while descending/ascending a freight elevator. Despite these movements and operating the instrument on battery power, the relative standard deviation of the total ion current was <5% and the magnitude of the mass error relative to the internal calibrant never exceeded 5.06 ppm. We further evaluated the feasibility of performing intraoperative MasSpec Pen analysis while operating the Orbitrap mass spectrometer on battery power during an ovarian cancer surgery. We observed that the rich and tissue-specific molecular profile commonly detected from ovarian tissues was conserved when running on battery power. Together, these results demonstrate that Orbitrap mass spectrometers can be operated and acquire data on battery power while in motion and in rotation without losses in signal stability or mass accuracy. Furthermore, Orbitrap mass spectrometers can be used in conjunction to the MasSpec Pen while on battery power for intraoperative tissue analysis.
Collapse
Affiliation(s)
- Michael F Keating
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
- Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, United States
| | - Charles A Wolfe
- Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, United States
| | - Keziah Liebenberg
- Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, United States
| | - Ashley Montgomery
- Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, United States
| | - Andreia M Porcari
- Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, United States
- MS4Life Laboratory of Mass Spectrometry, Health Sciences Postgraduate Program, Universidade São Francisco, Bragança Paulista, SP 12916-900, Brazil
| | - Nicole D Fleming
- Department of Surgery, MD Anderson Cancer Center, Houston, Texas 77030, United States
| | | | - Livia S Eberlin
- Department of Surgery, Baylor College of Medicine, Houston, Texas 77030, United States
| |
Collapse
|
2
|
Cafarella C, Mangraviti D, Rigano F, Dugo P, Mondello L. Rapid evaporative ionization mass spectrometry: A survey through 15 years of applications. J Sep Sci 2024; 47:e2400155. [PMID: 38772742 DOI: 10.1002/jssc.202400155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/15/2024] [Accepted: 04/16/2024] [Indexed: 05/23/2024]
Abstract
Rapid evaporative ionization mass spectrometry (REIMS) is a relatively recent MS technique explored in many application fields, demonstrating high versatility in the detection of a wide range of chemicals, from small molecules (phenols, amino acids, di- and tripeptides, organic acids, and sugars) to larger biomolecules, that is, phospholipids and triacylglycerols. Different sampling devices were used depending on the analyzed matrix (liquid or solid), resulting in distinct performances in terms of automation, reproducibility, and sensitivity. The absence of laborious and time-consuming sample preparation procedures and chromatographic separations was highlighted as a major advantage compared to chromatographic methods. REIMS was successfully used to achieve a comprehensive sample profiling according to a metabolomics untargeted analysis. Moreover, when a multitude of samples were available, the combination with chemometrics allowed rapid sample differentiation and the identification of discriminant features. The present review aims to provide a survey of literature reports based on the use of such analytical technology, highlighting its mode of operation in different application areas, ranging from clinical research, mostly focused on cancer diagnosis for the accurate identification of tumor margins, to the agri-food sector aiming at the safeguard of food quality and security.
Collapse
Affiliation(s)
- Cinzia Cafarella
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Messina Institute of Technology, former Veterinary School, University of Messina, Messina, Italy
| | - Domenica Mangraviti
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Messina Institute of Technology, former Veterinary School, University of Messina, Messina, Italy
| | - Francesca Rigano
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Messina Institute of Technology, former Veterinary School, University of Messina, Messina, Italy
| | - Paola Dugo
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Messina Institute of Technology, former Veterinary School, University of Messina, Messina, Italy
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Chromaleont s.r.l., former Veterinary School, University of Messina, Messina, Italy
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Messina Institute of Technology, former Veterinary School, University of Messina, Messina, Italy
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, Chromaleont s.r.l., former Veterinary School, University of Messina, Messina, Italy
| |
Collapse
|
3
|
Pekov SI, Bormotov DS, Bocharova SI, Sorokin AA, Derkach MM, Popov IA. Mass spectrometry for neurosurgery: Intraoperative support in decision-making. MASS SPECTROMETRY REVIEWS 2024. [PMID: 38571445 DOI: 10.1002/mas.21883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/29/2024] [Accepted: 03/23/2024] [Indexed: 04/05/2024]
Abstract
Ambient ionization mass spectrometry was proved to be a powerful tool for oncological surgery. Still, it remains a translational technique on the way from laboratory to clinic. Brain surgery is the most sensitive to resection accuracy field since the balance between completeness of resection and minimization of nerve fiber damage determines patient outcome and quality of life. In this review, we summarize efforts made to develop various intraoperative support techniques for oncological neurosurgery and discuss difficulties arising on the way to clinical implementation of mass spectrometry-guided brain surgery.
Collapse
Affiliation(s)
- Stanislav I Pekov
- Skolkovo Institute of Science and Technology, Moscow, Russian Federation
- Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
- Siberian State Medical University, Tomsk, Russian Federation
| | - Denis S Bormotov
- Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| | | | - Anatoly A Sorokin
- Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| | - Maria M Derkach
- Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| | - Igor A Popov
- Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
- Siberian State Medical University, Tomsk, Russian Federation
| |
Collapse
|
4
|
Rankin‐Turner S, Sears P, Heaney LM. Applications of ambient ionization mass spectrometry in 2022: An annual review. ANALYTICAL SCIENCE ADVANCES 2023; 4:133-153. [PMID: 38716065 PMCID: PMC10989672 DOI: 10.1002/ansa.202300004] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Revised: 04/16/2023] [Accepted: 04/17/2023] [Indexed: 06/28/2024]
Abstract
The development of ambient ionization mass spectrometry (AIMS) has transformed analytical science, providing the means of performing rapid analysis of samples in their native state, both in and out of the laboratory. The capacity to eliminate sample preparation and pre-MS separation techniques, leading to true real-time analysis, has led to AIMS naturally gaining a broad interest across the scientific community. Since the introduction of the first AIMS techniques in the mid-2000s, the field has exploded with dozens of novel ion sources, an array of intriguing applications, and an evident growing interest across diverse areas of study. As the field continues to surge forward each year, ambient ionization techniques are increasingly becoming commonplace in laboratories around the world. This annual review provides an overview of AIMS techniques and applications throughout 2022, with a specific focus on some of the major fields of research, including forensic science, disease diagnostics, pharmaceuticals and food sciences. New techniques and methods are introduced, demonstrating the unwavering drive of the analytical community to further advance this exciting field and push the boundaries of what analytical chemistry can achieve.
Collapse
Affiliation(s)
- Stephanie Rankin‐Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public HealthJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Patrick Sears
- School of Chemistry and Chemical EngineeringUniversity of SurreyGuildfordUK
| | - Liam M Heaney
- School of Sport, Exercise and Health SciencesLoughborough UniversityLoughboroughUK
| |
Collapse
|
5
|
King ME, Lin M, Spradlin M, Eberlin LS. Advances and Emerging Medical Applications of Direct Mass Spectrometry Technologies for Tissue Analysis. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:1-25. [PMID: 36944233 DOI: 10.1146/annurev-anchem-061020-015544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Offering superb speed, chemical specificity, and analytical sensitivity, direct mass spectrometry (MS) technologies are highly amenable for the molecular analysis of complex tissues to aid in disease characterization and help identify new diagnostic, prognostic, and predictive markers. By enabling detection of clinically actionable molecular profiles from tissues and cells, direct MS technologies have the potential to guide treatment decisions and transform sample analysis within clinical workflows. In this review, we highlight recent health-related developments and applications of direct MS technologies that exhibit tangible potential to accelerate clinical research and disease diagnosis, including oncological and neurodegenerative diseases and microbial infections. We focus primarily on applications that employ direct MS technologies for tissue analysis, including MS imaging technologies to map spatial distributions of molecules in situ as well as handheld devices for rapid in vivo and ex vivo tissue analysis.
Collapse
Affiliation(s)
- Mary E King
- Department of Chemistry, The University of Texas at Austin, Austin, Texas, USA;
- Department of Surgery, Baylor College of Medicine, Houston, Texas, USA;
| | - Monica Lin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas, USA;
| | - Meredith Spradlin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas, USA;
| | - Livia S Eberlin
- Department of Surgery, Baylor College of Medicine, Houston, Texas, USA;
| |
Collapse
|
6
|
Bogusiewicz J, Bojko B. Insight into new opportunities in intra-surgical diagnostics of brain tumors. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
7
|
Van Hese L, De Vleeschouwer S, Theys T, Rex S, Heeren RMA, Cuypers E. The diagnostic accuracy of intraoperative differentiation and delineation techniques in brain tumours. Discov Oncol 2022; 13:123. [PMID: 36355227 PMCID: PMC9649524 DOI: 10.1007/s12672-022-00585-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 10/22/2022] [Indexed: 11/11/2022] Open
Abstract
Brain tumour identification and delineation in a timeframe of seconds would significantly guide and support surgical decisions. Here, treatment is often complicated by the infiltration of gliomas in the surrounding brain parenchyma. Accurate delineation of the invasive margins is essential to increase the extent of resection and to avoid postoperative neurological deficits. Currently, histopathological annotation of brain biopsies and genetic phenotyping still define the first line treatment, where results become only available after surgery. Furthermore, adjuvant techniques to improve intraoperative visualisation of the tumour tissue have been developed and validated. In this review, we focused on the sensitivity and specificity of conventional techniques to characterise the tumour type and margin, specifically fluorescent-guided surgery, neuronavigation and intraoperative imaging as well as on more experimental techniques such as mass spectrometry-based diagnostics, Raman spectrometry and hyperspectral imaging. Based on our findings, all investigated methods had their advantages and limitations, guiding researchers towards the combined use of intraoperative imaging techniques. This can lead to an improved outcome in terms of extent of tumour resection and progression free survival while preserving neurological outcome of the patients.
Collapse
Affiliation(s)
- Laura Van Hese
- Division of Mass Spectrometry Imaging, Maastricht MultiModal Molecular Imaging (M4I) Institute, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
- Department of Anaesthesiology, University Hospitals Leuven, 3000, Leuven, Belgium
- Department of Cardiovascular Sciences, KU Leuven, 3000, Leuven, Belgium
| | - Steven De Vleeschouwer
- Neurosurgery Department, University Hospitals Leuven, 3000, Leuven, Belgium
- Laboratory for Experimental Neurosurgery and Neuroanatomy, Department of Neurosciences, Leuven Brain Institute (LBI), 3000, Leuven, Belgium
| | - Tom Theys
- Neurosurgery Department, University Hospitals Leuven, 3000, Leuven, Belgium
- Laboratory for Experimental Neurosurgery and Neuroanatomy, Department of Neurosciences, Leuven Brain Institute (LBI), 3000, Leuven, Belgium
| | - Steffen Rex
- Department of Anaesthesiology, University Hospitals Leuven, 3000, Leuven, Belgium
- Department of Cardiovascular Sciences, KU Leuven, 3000, Leuven, Belgium
| | - Ron M A Heeren
- Division of Mass Spectrometry Imaging, Maastricht MultiModal Molecular Imaging (M4I) Institute, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands
| | - Eva Cuypers
- Division of Mass Spectrometry Imaging, Maastricht MultiModal Molecular Imaging (M4I) Institute, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
| |
Collapse
|
8
|
Morato NM, Brown HM, Garcia D, Middlebrooks EH, Jentoft M, Chaichana K, Quiñones-Hinojosa A, Cooks RG. High-throughput analysis of tissue microarrays using automated desorption electrospray ionization mass spectrometry. Sci Rep 2022; 12:18851. [PMID: 36344609 PMCID: PMC9640715 DOI: 10.1038/s41598-022-22924-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 10/20/2022] [Indexed: 11/09/2022] Open
Abstract
Tissue microarrays (TMAs) are commonly used for the rapid analysis of large numbers of tissue samples, often in morphological assessments but increasingly in spectroscopic analysis, where specific molecular markers are targeted via immunostaining. Here we report the use of an automated high-throughput system based on desorption electrospray ionization (DESI) mass spectrometry (MS) for the rapid generation and online analysis of high-density (6144 samples/array) TMAs, at rates better than 1 sample/second. Direct open-air analysis of tissue samples (hundreds of nanograms) not subjected to prior preparation, plus the ability to provide molecular characterization by tandem mass spectrometry (MS/MS), make this experiment versatile and applicable to both targeted and untargeted analysis in a label-free manner. These capabilities are demonstrated in a proof-of-concept study of frozen brain tissue biopsies where we showcase (i) a targeted MS/MS application aimed at identification of isocitrate dehydrogenase mutation in glioma samples and (ii) an untargeted MS tissue type classification using lipid profiles and correlation with tumor cell percentage estimates from histopathology. The small sample sizes and large sample numbers accessible with this methodology make for a powerful analytical system that facilitates the identification of molecular markers for later use in intraoperative applications to guide precision surgeries and ultimately improve patient outcomes.
Collapse
Affiliation(s)
- Nicolás M. Morato
- grid.169077.e0000 0004 1937 2197Department of Chemistry, Purdue Center for Cancer Research, and Bindley Bioscience Center, Purdue University, 560 Oval Drive, West Lafayette, IN 47907 USA
| | - Hannah Marie Brown
- grid.169077.e0000 0004 1937 2197Department of Chemistry, Purdue Center for Cancer Research, and Bindley Bioscience Center, Purdue University, 560 Oval Drive, West Lafayette, IN 47907 USA ,grid.4367.60000 0001 2355 7002Present Address: Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO USA
| | - Diogo Garcia
- grid.417467.70000 0004 0443 9942Department of Neurosurgery, Mayo Clinic, Jacksonville, FL USA
| | - Erik H. Middlebrooks
- grid.417467.70000 0004 0443 9942Department of Neurosurgery, Mayo Clinic, Jacksonville, FL USA ,grid.417467.70000 0004 0443 9942Department of Radiology, Mayo Clinic, Jacksonville, FL USA
| | - Mark Jentoft
- grid.417467.70000 0004 0443 9942Department of Laboratory Medicine and Pathology, Mayo Clinic, Jacksonville, FL USA
| | - Kaisorn Chaichana
- grid.417467.70000 0004 0443 9942Department of Neurosurgery, Mayo Clinic, Jacksonville, FL USA
| | | | - R. Graham Cooks
- grid.169077.e0000 0004 1937 2197Department of Chemistry, Purdue Center for Cancer Research, and Bindley Bioscience Center, Purdue University, 560 Oval Drive, West Lafayette, IN 47907 USA
| |
Collapse
|
9
|
Advances in MS instrumentation: The present and future of the clinical lab. J Mass Spectrom Adv Clin Lab 2022; 26:21-22. [DOI: 10.1016/j.jmsacl.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|