1
|
Kyaw MS, Ebihara A, Iino Y, Thu M, Maki K, Kimura S, Htun PH, Okiji T. Effect of preset torque setting on torque/force generation, shaping ability and surface changes of nickel titanium rotary instrument in different root canal curvature locations: An ex vivo study. Dent Mater J 2024; 43:329-337. [PMID: 38583993 DOI: 10.4012/dmj.2023-244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
The aim of this study was to evaluate how preset torque settings influence the torque, vertical force, and root canal-centering ability of ProGlider and ProTaper NEXT nickel-titanium rotary instruments in canals with different curvature locations. Based on micro-computed tomography, mesial roots of human mandibular molars (25°-40° curvature) were allocated to the apical curvature (apical 1-5 mm) or the middle curvature (apical 5-9 mm) groups, and mandibular incisors (curvature <5°) to the straight canal group. Each group was subjected to automated instrumentation and torque/force measurement with the preset torque of 1, 2.5, or 5 N•cm. Canal-centering ratios were determined with micro-computed tomography. Instrument fracture occurred only in the 2.5 and 5 N•cm groups in curved canals. The preset torque setting and curvature location did not influence canal shaping ability.
Collapse
Affiliation(s)
- Moe Sandar Kyaw
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
- Department of Conservative Dentistry, University of Dental Medicine (Mandalay)
| | - Arata Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Yoshiko Iino
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Myint Thu
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Keiichiro Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Shunsuke Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Pyae Hein Htun
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Takashi Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| |
Collapse
|
2
|
Diaconu CT, Diaconu AE, Tuculina MJ, Mihai LL, Gheorghiță M, Gheorghiță LM, Mărășescu P, Gliga A, Diaconu OA. Assessment of the Cyclic Fatigue Performance of the Novel Protaper Ultimate File System Used in Different Kinematics: An In Vitro Study. J Funct Biomater 2024; 15:85. [PMID: 38667542 PMCID: PMC11051539 DOI: 10.3390/jfb15040085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 03/06/2024] [Accepted: 03/27/2024] [Indexed: 04/28/2024] Open
Abstract
This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals. As far as the authors are aware, no study has previously compared the three file systems before this current investigation. Therefore, closing this information gap is the goal of the current research. Methods: A total of (60 new endodontic files were randomly divided into 6 groups (10 files per group); groups 1, 3, and 5 used continuous rotation (CR), while groups 2, 4, and 6 used forward reciprocating motion (FRM). A manufactured stainless-steel artificial canal was used to perform the cyclic fatigue testing. The results were analyzed using Student's t-test and two-way ANOVA. All pairwise comparisons revealed statistically significant differences in the time to failure (TTF) for every study group (p < 0.001), with the exception of the PTG and M3 files, which performed similarly using both CR and FRM. Conclusions: The PTU files performed better than the PTG and M3 files in terms of the TTF and number of cycles to failure (NCF) using both CR and FRM.
Collapse
Affiliation(s)
- Cezar Tiberiu Diaconu
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Anca Elena Diaconu
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Mihaela Jana Tuculina
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Laurența Lelia Mihai
- Faculty of Dental Medicine, University Titu Maiorescu of Bucharest, 031593 Bucharest, Romania
| | - Mircea Gheorghiță
- Faculty of Dental Medicine, Department of Oral and Maxillofacial Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Lelia Mihaela Gheorghiță
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Petre Mărășescu
- Faculty of Dental Medicine, Department of Dental Prothesis Technology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Alexandru Gliga
- Faculty of Dental Medicine, Department of Operative Dentistry, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania;
| | - Oana Andreea Diaconu
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| |
Collapse
|
3
|
Chalikkandy SN, Bhandi S, Shawkani HAAA, Wadei MHDA, Mohammed Abdul Kader M, Jaafari AHH, Vinothkumar TS, Varadarajan S, Testarelli L, Patil S. A systematic review assessing the dental pulp stone prevalence in the Saudi Arabian population. Saudi Dent J 2023; 35:803-811. [PMID: 38077230 PMCID: PMC10699125 DOI: 10.1016/j.sdentj.2023.07.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 07/10/2023] [Accepted: 07/18/2023] [Indexed: 06/21/2024] Open
Abstract
This Systematic Review (SR) was to report on the prevalence of pulp stones in the Saudi Arabian (KSA) population. The electronic databases were searched for scientific research articles during May 2021. The data search was performed in electronic search engines like PubMed, Scopus, Web of science, and Saudi Digital Library, and 6 original research articles which fulfilled the eligibility criteria were assessed for qualitative data. The prevalence of pulp stones among the KSA population ranged from 4.6% to 50.93% among the study participants and it ranged between 10.2%-13.34% in the teeth assessed. The pulp stones were more frequently reported in decayed teeth, periodontal diseases, attrition, teeth with dental restorations, and higher in the molar teeth in comparison with the premolar teeth. The data on the prevalence of pulp stones among the Saudi population will be helpful for clinicians in planning endodontic procedures.
Collapse
Affiliation(s)
| | - Shilpa Bhandi
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA
| | - Hamed Ahmed Ali Al Shawkani
- Department of Restorative Dental Science, Division of Endodontics, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | | | - M. Mohammed Abdul Kader
- Department of Restorative Dental Science, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | - Thilla Sekar Vinothkumar
- Department of Restorative Dental Science, Division of Operative Dentistry, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | - Saranya Varadarajan
- Distinguished Adjunct Faculty, Department of Oral Pathology and Microbiology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600 077, India
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, University di Roma La Sapienza, Roma 00185, Italy
| | - Shankargouda Patil
- College of Dental Medicine, Roseman University of Health Sciences, South Jordan, UT 84095, USA
| |
Collapse
|
4
|
Ex Vivo Comparison of File Fracture and File Deformation in Canals with Moderate Curvature: Neolix Rotary System versus Manual K-files. JOURNAL OF RESEARCH IN DENTAL AND MAXILLOFACIAL SCIENCES 2022. [DOI: 10.52547/jrdms.7.4.219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023] Open
|
5
|
Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12126253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25), 10 WaveOne Gold (WOG), 10 EdgeOne Fire (EOF) and 10 recently introduced instruments OneRECI (OR), for a total of 40 new instruments. Before root canal shaping, each instrument is mounted on a stub in a standardized position and observed using a scanning electron microscope (SEM) to detect any surface alteration, such as microfractures, metal defects, deformations, blunt and disruption of cutting edges, debris, pitting and tip flattening. Micrographs are acquired at the level of the tip, 4 mm, 8 mm and 12 mm from it. After that, each instrument is used in four simulated resin root canals. SEM observation was repeated after the simulated clinical use to assess the wear resistance of the instruments. Surface alterations are registered before and after instrumentation and statistical analysis is performed using a Chi-Square test to verify homogeneity of defects distribution and GLM to evaluate the differences of RMS at baseline and after use for both groups (α level 0.05). Before simulated clinical uses, no alterations are found except for three cases of EOF with metal strips in correspondence to the tip, disruption of the cutting edge of WOG and oily spotting on two different OR. After simulated clinical use, EOF shows a statistically significant difference in terms of spiral distortion and flattening of the cutting edges. The OR shows the highest presence of debris despite the ultrasonic cleaning procedures. No instrument fractures are observed. EOF should be discarded after four clinical uses and carefully inspected after each insertion into root canals. Moreover, tough attention should be paid during disinfection and cleaning procedures after instrumentation considering the copious debris detected in each instrument, particularly in OR.
Collapse
|
6
|
Seracchiani M, Reda R, Zanza A, D'Angelo M, Russo P, Luca T. Mechanical performance and Metallurgical Characteristic of Five Different Single-File Reciprocating Instruments: a Comparative in Vitro and Laboratory Study. J Endod 2022; 48:1073-1080. [PMID: 35667568 DOI: 10.1016/j.joen.2022.05.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 04/16/2022] [Accepted: 05/26/2022] [Indexed: 11/18/2022]
Abstract
INTRODUCTION Since there are no data regarding an instrument recently introduced on the market (OneRECI), the aim of the study was to assess its mechanical and metallurgical properties comparing them with those of widespread reciprocating instruments such as Reciproc, Reciproc Blue, EdgeOne Fire and WaveOne Gold. METHODS A total of 65 NiTi files from five different reciprocating systems (OneRECI, Reciproc, Reciproc Blue, EdgeOne Fire and WaveOne Gold) were evaluated throughout a combined mechanical and metallurgical method. Mechanical performances of the selected file were examined subjecting each specimen to cyclic fatigue, torsional and bending resistance tests, whilst their metallurgical properties were assessed analyzing the nickel-titanium alloy composition and the phase transformation temperatures respectively through an energy-dispersive X-ray spectroscopy (EDX) and a differential scanning calorimetry (DSC). One-way ANOVA and post hoc Tukey's was performed with significance level set to a 95% confidence level. RESULTS The EDX showed a similar alloy composition for all of the tested files, with nickel percentage of about 52-53% and a corresponding percentage of titanium of 47-48%, whilst the DSC analysis, although evidenced martensitic characteristics for all files, showed differences in terms of phase transformation temperatures. Overall, OneRECI showed the best mechanical performances in terms of cyclic fatigue and torsional resistance (respectively of 32.95 ± 2.33 s and 0.76 ± 0.03 Ncm) and flexibility (48.4 ± 4.1 g), with statistically significant differences for all tests (p<0.05). Reciproc files showed the worst flexibility and cyclic fatigue resistance, respectively of 157.2 ± 8.3 g and 9.27 ± 1.18 s, whilst the EdgeOne Fire showed the lowest torsional resistance (0.39 ± 0.12 Ncm), whit statistically significant differences (p<0.05). CONCLUSIONS Within the limitation of this study, the recently introduced file OneRECI showed the best mechanical performance in comparison to the tested instruments, with an equiatomic composition of the NiTi alloy and a martensitic behavior.
Collapse
Affiliation(s)
- Marco Seracchiani
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Rodolfo Reda
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy.
| | - Maurilio D'Angelo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Paola Russo
- Department of Chemical Engineering, Materials, Environment Dipartimento di Ingegneria Chimica Materiali Ambiente, La Sapienza University of Rome, Rome, Italy
| | - Testarelli Luca
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
7
|
Mechanical and Metallurgical Evaluation of 3 Different Nickel-Titanium Rotary Instruments: An In Vitro and In Laboratory Study. Bioengineering (Basel) 2022; 9:bioengineering9050221. [PMID: 35621499 PMCID: PMC9137481 DOI: 10.3390/bioengineering9050221] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/11/2022] [Accepted: 05/18/2022] [Indexed: 11/17/2022] Open
Abstract
An in-depth evaluation of the mechanical and metallurgical properties of NiTi instruments is fundamental to assess their performance and to compare recently introduced instrument with widespread ones. According to this, since there are no data on this topic, the aim of the study was to mechanically and metallurgically evaluate an instrument recently introduced into the market (ZenFlex (ZF)), by comparing it with two well-known instruments with similar characteristics: Vortex Blue (VB) and EdgeSequel Sapphire (EES). According to this, 195 instruments were selected: 65 ZF, 65 VB and 65 EES. Each group was divided in subgroups according to the mechanical tests (i.e., cyclic fatigue resistance, torsional resistance and bending ability; (n = 20)) and the metallurgical test (differential scanning calorimetry (n = 5)). A scanning electron microscopy was performed to verify the causes of fracture after mechanical tests (cyclic fatigue and torsional tests). According to results, VB showed the highest flexibility and cyclic fatigue resistance in comparison to the other instruments, with a statistically significant difference (p < 0.05). Regarding torsional resistance, EES showed the lowest value of torque at fracture, with a statistically significant difference, whilst the comparison between ZF and VB showed no statistically significant difference (p > 0.05). DSC analysis pointed out that VB had the highest austenite start and finish temperatures, followed by ESS and then ZF. ESS sample showed the highest martensite start and finish temperatures followed by VB and ZF. Considering the results, it can be concluded that VB showed the best mechanical performance during static tests in comparison to ESS and ZF. This is fundamentally due to the interaction of parameters such as instrument design and heat-treatments that are able to enhance its mechanical performance.
Collapse
|
8
|
Future Trends in Endodontics: How Could Materials Increase the Long-Term Outcome of Root Canal Therapies? MATERIALS 2022; 15:ma15103473. [PMID: 35629501 PMCID: PMC9146320 DOI: 10.3390/ma15103473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 05/11/2022] [Indexed: 02/04/2023]
|
9
|
Basturk FB, Özyürek T, Uslu G, Gündoğar M. Mechanical Properties of the New Generation RACE EVO and R-Motion Nickel-Titanium Instruments. MATERIALS 2022; 15:ma15093330. [PMID: 35591664 PMCID: PMC9105925 DOI: 10.3390/ma15093330] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 04/21/2022] [Accepted: 05/03/2022] [Indexed: 12/04/2022]
Abstract
This study aimed to evaluate and compare the dynamic cyclic fatigue, torsional and bending resistance of two novel RACE EVO (FKG Dentaire SA, La Chaux de Fonds, Switzerland) and R-Motion (FKG) nickel−titanium instruments with traditional RaCe (FKG) instruments. RACE EVO, R-Motion and RaCe instruments with a size of 25 and taper of 0.06 were used. A dynamic cyclic fatigue test was used to assess the time to fracture. The fractured surfaces were further analyzed using scanning electron microscopy at ×350 and ×3000 magnifications. A torsional resistance test was performed to measure the maximum torsional strength and angle of rotation. Phase transformations with temperature were evaluated using differential scanning calorimetry. The results were statistically analyzed with a Kruskal−Wallis test at a 5% significance level. R-Motion had the highest time to fracture and the lowest torsional and bending resistance, whereas RaCe had the lowest time to fracture and the highest torsional and bending resistance (p < 0.05). In relation to the angle of rotation, RACE EVO instruments had the highest deformation capacity followed by R-Motion and RaCe instruments (p < 0.05). The greater cyclic fatigue resistance and lower torsional and bending resistance results indicate that the novel R-Motion and RACE EVO instruments are less rigid and more flexible than RaCe instruments.
Collapse
Affiliation(s)
- Fatima Betul Basturk
- Department of Endodontics, Istanbul Gelişim University, Istanbul 34310, Turkey
- Correspondence:
| | - Taha Özyürek
- Department of Endodontics, Bahçeşehir University, Istanbul 34734, Turkey;
| | - Gülşah Uslu
- Department of Endodontics, Çanakkale Onsekiz Mart University, Çanakkale 17100, Turkey;
| | - Mustafa Gündoğar
- Department of Endodontics, Istanbul Medipol University, Istanbul 34083, Turkey;
| |
Collapse
|
10
|
Faus-Matoses V, Pérez García R, Faus-Llácer V, Faus-Matoses I, Alonso Ezpeleta Ó, Albaladejo Martínez A, Zubizarreta-Macho Á. Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19074414. [PMID: 35410096 PMCID: PMC8998441 DOI: 10.3390/ijerph19074414] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 02/04/2023]
Abstract
In this study, we compare and analyze the scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), morphometry and cyclic fatigue resistance of Endogal, PathMax, and Smarttrack novel brands of nickel−titanium (NiTi) alloy endodontic files. Material and Methods: Thirty sterile NiTi endodontic rotary files were randomly selected and assigned to one of the following study groups: A: 25.08 F2 Endogal (EDG) (n = 10); B: 25.08 F2 Path Max Pro (PMP) (n = 10); and C: 25.06 Smarttrack (ST) (n = 10). Dynamic cyclic fatigue tests were conducted using a cyclic fatigue device in stainless steel artificial root canal systems with an apical diameter of 250 µm, curvature angle of 60°, radius of curvature of 3 mm, and taper of 6%. Additionally, we analyzed the NiTi endodontic rotary files using EDX, SEM, and morphometry after micro-CT scanning. The results were analyzed using Weibull statistical analysis and ANOVA testing. Results: SEM, EDX, and morphometric analyses showed differences between the three novel brands of NiTi endodontic rotary files. Moreover, statistically significant differences were observed between the number of cycles to failure and time to failure of the three novel brands of NiTi endodontic rotary files (p < 0.001). Conclusions: Smarttrack NiTi alloy endodontic reciprocating files display greater resistance to cyclic fatigue than Endogal and Path Max Pro NiTi alloy endodontic rotary files, due to the reciprocating movement and metallurgical composition.
Collapse
Affiliation(s)
- Vicente Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Raúl Pérez García
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Vicente Faus-Llácer
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Ignacio Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
- Correspondence:
| | - Óscar Alonso Ezpeleta
- Department of Endodontics, School of Health Sciences, University of Zaragoza, 22006 Zaragoza, Spain;
| | - Alberto Albaladejo Martínez
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain; (A.A.M.); or (Á.Z.-M.)
| | - Álvaro Zubizarreta-Macho
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain; (A.A.M.); or (Á.Z.-M.)
- Department of Endodontics, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain
| |
Collapse
|
11
|
Zanza A, Russo P, Di Matteo P, Reda R, Di Nardo D, Gambarini G, Testarelli L. Mechanical properties and metallurgical features of two similar endodontic rotary instruments with different heat treatments (FireWire™ and Gold). Sci Prog 2022; 105:368504221103763. [PMID: 35656775 PMCID: PMC10364944 DOI: 10.1177/00368504221103763] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The aim of this study was to explain the mechanical differences between EdgeTaper Platinum (ETP) and ProTaper Gold (PTG) determining the transition temperatures and the composition of the alloy of ETP, since no data are present in literature. A total of 130 instruments were selected: 65 ETP F2 and 65 PTG F2. 20 instruments per type were submitted to each mechanical tests. The cyclic fatigue and torsional tests were performed at a pre-set temperature of 35 °C ± 1 °C. During the cyclic fatigue test, Time to fracture, number of cycles to fracture (NCF) and the fragment length (FL) were recorded. During the static torsional, Torque to Fracture (TtF) and FL were recorded. The fracture surface of 5 randomly selected fragments from each test was examined through a Scanning Electron Microscopy (SEM) and an EDX analysis was performed. 20 instruments per type were submitted to a bending test The force generated (grams) to bend each was recorded. Recorded data of mechanical and metallurgical tests were statistically analyzed using a one-way analysis of variance (ANOVA) test with significance set to a 95% confidence level. ETP F2 showed a higher cyclic fatigue resistance and bending ability than PTG F2, with a statistically significant difference (p < 0.05). PTG showed a higher torsional resistance with a statistically significant difference (p < 0.05). DSC analysis of 5 samples for each instrument type pointed out that the austenite finish temperature of PTG was higher than the ETP, respectively of 49.99 ± 3.31 (°C) and 38.92 ± 1.75 (°C). EDX analysis confirmed the near-equiatomic composition of the Ni-Ti alloys, with a presence of a third component recognized as rubidium in the ETP samples. ETP showed higher flexibility in comparison with PTG, despite the latter is characterized by a more martensitic characterization. since its Af temperature is higher than the ETP.
Collapse
Affiliation(s)
- Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, via Caserta 6, 00161 Rome, Italy
| | - Paola Russo
- Department of Chemical Engineering, Materials, Environment DICMA, La Sapienza University of Rome, via Scarpa, 00161 Rome, Italy
| | - Paola Di Matteo
- Department of Chemical Engineering, Materials, Environment DICMA, La Sapienza University of Rome, via Scarpa, 00161 Rome, Italy
| | - Rodolfo Reda
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, via Caserta 6, 00161 Rome, Italy
| | - Dario Di Nardo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, via Caserta 6, 00161 Rome, Italy
| | - Gianluca Gambarini
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, via Caserta 6, 00161 Rome, Italy
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, via Caserta 6, 00161 Rome, Italy
| |
Collapse
|
12
|
Kyaw MS, Ebihara A, Maki K, Kimura S, Nakatsukasa T, Htun PH, Thu M, Omori S, Okiji T. Effect of kinematics on the torque/force generation, surface characteristics, and shaping ability of a nickel titanium rotary glide path instrument: an ex-vivo study. Int Endod J 2022; 55:531-543. [PMID: 35263803 DOI: 10.1111/iej.13718] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 03/01/2022] [Accepted: 03/01/2022] [Indexed: 11/30/2022]
Abstract
AIM To evaluate the effect of various rotational motions on the torque/force generation, surface wear, and shaping ability of the ProGlider glide path instrument (Dentsply Sirona). METHODOLOGY Mesiobuccal and mesiolingual canals of mandibular molars were selected based on the canal volume, length, angle of curvature (25°-40°), and radius of curvature (4-8 mm) after micro-computed tomographic scanning. The samples were randomly assigned to four groups (n = 13, each) according to movement kinematics [continuous rotation (CR; 300 rpm), optimum torque reverse motion (OTR; 180° forward and 90° reverse when torque > 0.4 N·cm), time-dependent reciprocal motion (TmR; 180° forward and 90° reverse), and optimum glide path motion (OGP; a combination of 90° forward, 90° reverse, 90° forward, and 120° reverse)]. Instrumentation was performed with an automated root canal instrument and torque/force analysing device. Maximum torque/force values, canal volume changes, and canal-centring ratios at 1, 3, 5, and 7 mm were evaluated. Surface defects (pits, grooves, microcracks, blunt cutting edges, and disruption of cutting edges) and spiral distortion on the ProGlider instrument were scored at the tip and 5 mm short of the tip before and after five consecutive uses with scanning electron microscopy. The Kruskal-Wallis test followed by Dunn's post-test with Bonferroni correction and Wilcoxon signed-rank test were used to analyse the data (α = 0.05). RESULTS OGP generated significantly less clockwise torque and greater upward force than other groups (P < 0.05). OGP resulted in significantly fewer surface defects than CR (P < 0.05). In OGP and CR, the tip exhibited more surface defects than 5 mm short of the tip (P < 0.05). CR resulted in greater volume changes than OGP and TmR (P < 0.05) and greater centring ratios (i.e., more deviation) than OGP at 1 mm and OTR at 3 mm (P < 0.05). CONCLUSIONS Under laboratory conditions using the ProGlider instrument, OGP generated significantly less clockwise torque and greater upward force than the other rotatory motions. OGP generated fewer superficial defects than CR, and the three modes of reciprocal rotation better maintained the apical curvature of root canals than CR with the ProGlider instrument.
Collapse
Affiliation(s)
- M S Kyaw
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.,Department of Conservative Dentistry, University of Dental Medicine (Mandalay), Mandalay, Myanmar
| | - A Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - K Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - S Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - T Nakatsukasa
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - P H Htun
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - M Thu
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - S Omori
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - T Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| |
Collapse
|
13
|
Nickel–Titanium Rotary Instruments: Mechanical and Metallurgical Characteristics. Clin Pract 2022; 12:94-96. [PMID: 35200263 PMCID: PMC8870687 DOI: 10.3390/clinpract12010012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 02/10/2022] [Indexed: 02/04/2023] Open
|
14
|
Mohamed RH, Abdelrahman AM, Sharaf AA. Evaluation of rotary file system (Kedo-S-Square) in root canal preparation of primary anterior teeth using cone beam computed tomography (CBCT)-in vitro study. BMC Oral Health 2022; 22:13. [PMID: 35042489 PMCID: PMC8764846 DOI: 10.1186/s12903-021-02021-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 12/13/2021] [Indexed: 11/12/2022] Open
Abstract
Background In recent years, pediatric endodontics has witnessed various advances including use of rotary files in pulpectomy. This study aimed to comparatively evaluate taper, amount of dentin removal and instrumentation time of the pediatric rotary Kedo-S Square file,
hand K-files and H-files in primary canines using cone beam computed tomography (CBCT). Methods 60 primary canines were randomly assigned into three groups; A1 Kedo-S-Square rotary file (group I), hand stainless steel K file (group II) and hand stainless steel H file (group III). Teeth were mounted in vinyl poly siloxane impression material templates to be scanned before and after instrumentation by CBCT scans using Ondemand 3D software. Shaping ability of the files were evaluated in terms of taper of the canal and amount of dentin remaining of each group. Instrumentation time was recorded using a digital stopwatch. Results Kedo-S Square removed a significantly less amount of dentin in both apical (P < 0.002) and coronal thirds (P < 0.014). Taper of the preparations showed significant differences as Kedo-S Square file showed good taper in maximum number of root canals, while maual K- and H-files showed poor taper in maximum number of root canals (P < 0.0001). Rotary Kedo-S Square files required less instrumentation time (P < 0.0001). Conclusion The use of rotary Kedo-S Square files resulted in better conservation of tooth structure, superior tapering ability and least instrumentation time compared to hand K- and H-files.
Collapse
|
15
|
Orhan EO, Bahadır D, Irmak O. Kinematics of 'Adaptive Motion' under constant torque values. J Endod 2022; 48:355-361. [PMID: 34999094 DOI: 10.1016/j.joen.2021.12.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 12/24/2021] [Accepted: 12/31/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION To demonstrate the unknown kinematics of complex adaptive motion with respect to disclosed values, the aim of the present study was (i)to analyze the adaptive motion and (ii)to compare the effects of constant torque values on kinematics. METHODS A new endodontic motor(Aseptico AEU-28SYB Elements) and 8:1 contra-angle handpiece were used for analysis. A pilot test was conducted for synchronizing the external experimental stress on the shaft of the target object and the inbuilt torque sensor of the motor source. A load setup was developed by attaching universal precision weights to the shaft of the of the target object. The groups were adaptive motion with no load(TFA-0), adaptive motion with 100 gcm(TFA-100), and 200 gcm(TFA-200) constant load. The peak-to-peak based phase identification method was used to analyze the kinematics. Student's t and Mann Whitney U tests were used where applicable(α=0.05). RESULTS A noteworthy observation was the inconsistent kinematics of the TFA-100 compared to the kinematics of TFA-0 and TFA-200. TFA-100 presented mixed-phased kinematics, which consisted of both quaternary(n=33) phases similar to that of TFA-200, and dual(n=17) phases similar to that of TFA-0. The sequence of these quaternary and dual phases of TFA-100 was arbitrarily changing. The kinematic parameters of dual-phase intermittent motion of TFA-0 and TFA-100 and quaternary-phase reciprocating motion of TFA-100 and TFA-200 revealed significant differences(p<0.05). CONCLUSIONS The main conclusions of the present study are the kinematics of adaptive motion was demonstrated and the 100 gcm load is not sufficient for predictable and constant operation in reciprocating mode.
Collapse
Affiliation(s)
- Ekim Onur Orhan
- Translational Medicine Research and Clinical Center, Eskisehir Osmangazi University, TR26040, Eskisehir, Turkey; Computer-Aided Diagnosis and Treatment Application and Research Center in Healthcare, Eskisehir Osmangazi University, 26040 Eskisehir, Turkey; Department of Endodontics, Faculty of Dentistry, Eskişehir Osmangazi University, TR26040 Eskişehir, Turkey.
| | - Duygu Bahadır
- Department of Endodontics, Faculty of Dentistry, Eskişehir Osmangazi University, TR26040 Eskişehir, Turkey
| | - Ozgur Irmak
- Department of Restorative Dentistry, Faculty of Dentistry, Near East University, Nicosia / TRNC Mersin 10, Turkey
| |
Collapse
|
16
|
Zanza A, D’Angelo M, Reda R, Gambarini G, Testarelli L, Di Nardo D. An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective-An Overview. Bioengineering (Basel) 2021; 8:bioengineering8120218. [PMID: 34940371 PMCID: PMC8698980 DOI: 10.3390/bioengineering8120218] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 12/10/2021] [Accepted: 12/13/2021] [Indexed: 12/21/2022] Open
Abstract
Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.
Collapse
|
17
|
Role of the Crystallographic Phase of NiTi Rotary Instruments in Determining Their Torsional Resistance during Different Bending Conditions. MATERIALS 2021; 14:ma14216324. [PMID: 34771850 PMCID: PMC8585440 DOI: 10.3390/ma14216324] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 10/13/2021] [Accepted: 10/19/2021] [Indexed: 11/16/2022]
Abstract
The aim of this study was to assess the role of the crystallographic phase of Nickel-titanium (NiTi) rotary instruments in determining their torsional resistance during different bending conditions, such as different degrees and angles of curvature. 200 F-One 20.04 instruments (Fanta Dental, Shanghai, China) were used, 100 austenitic instruments and 100 martensitic instruments. Each group was divided in 5 subgroups according to the different bending conditions (straight canal, 90° or 60° of curvature degrees and 3 mm or 5 mm of radius of curvature). The static torsional test was performed by using a device composed of an electric motor capable of recording torque values (N·cm); a vice used to secure the instruments at 3 mm from the tip; and artificial canals, which allow instruments to remain flexed during test. Each instrument was rotated at 500 rpm with a torque limit set to 5.5 Ncm until its fracture. Torque at Fracture (TtF) was registered. A scanning electron microscopy (SEM) observation was conducted. The collected data confirm that an increase in the angle of curvature and a decrease in the radius of curvature of the artificial canals lead to an increase of TtF values with a statistically significant difference (p < 0.05), both in the austenitic and martensitic groups. Regarding the comparison between austenitic and martensitic groups in the same bending condition, a statistically significant difference was found only when the torsional test was performed in the canals with the degrees of curvature of 90° and the radius of curvature of 3 mm and 5 mm, with the austenitic instruments showing a higher TtF than the martensitic ones. In conclusion, it can be stated that the crystallographic phase influences the maximum torque at fracture when the instruments are subjected to severe bending and that the radius of curvature significantly influences their torsional resistance.
Collapse
|
18
|
Experimental Study of the Effects of Torsional Loading on Three Types of Nickel-Titanium Endodontic Instruments. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11167224] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
In modern endodontics, nickel-titanium (NiTi) rotary instruments are used on a large scale for root canal shaping. Nevertheless, the separation of an instrument is a serious concern during shaping. The aim of this study is to determine and compare the torsional fracture characteristics of three types of NiTi endodontic instruments, each with different cross-section designs and movements performed during root canal shaping: Endostar E3 (Endostar, Poldent Co. Ltd., Warsaw, Poland); Reciproc R25 (VDW, Munich, Germany); and Protaper Next X2 (Dentsply Maillefer, Ballaigues, Switzerland). Fifteen instruments are used in this study, divided in three groups (n = 5): Group Endostar, Group Reciproc and Group Protaper. For testing, each instrument is used to shape five simulated root canals, following which its torsional stress to failure is measured. The fracture lengths of all three groups are roughly between 2 and 3 mm from the tip. Higher values of the moment of torsion in fracture, and smaller values of the maximum twisting angle are observed for Group Endostar, as well as closer to circular cross-sections. However, the values of the shear tension are similar for all three groups, because the disadvantage given by the fracture section shape for Groups Reciproc and Protaper is compensated either by size or by intrinsic properties of the instrument material. For the shear tension the Endostar values are insignificantly increased (Kruskal–Wallis test, p = 0.207), and in the case of the maximum twist angle the Protaper values are insignificantly increased (Kruskal–Wallis test, p = 0.287). Because of the instruments shape and conicity, the analysis had to be carried out separately with regard to the length of the fractured tip. Rules-of-thumb are extracted from the study for current practice: if a blockage of the first 2 to 3 mm part of the tip can be anticipated (by the excessive curving of the instrument), the handpiece must be adjusted to torque values that do not exceed 1.5 to 2.5 N · cm for Endostar and 1 to 2 N · cm for Reciproc and Protaper instruments.
Collapse
|
19
|
Angle of Insertion and Torsional Resistance of Nickel-Titanium Rotary Instruments. MATERIALS 2021; 14:ma14133744. [PMID: 34279315 PMCID: PMC8269838 DOI: 10.3390/ma14133744] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 06/25/2021] [Accepted: 06/30/2021] [Indexed: 12/20/2022]
Abstract
Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to investigate the influence of the angle of access on the torsional resistance of endodontic instruments. One hundred and eighty instruments were selected: 90 F-One Blue 25/04 and 90 HeroShaper 25/04 instruments. Three subgroups (n = 30) for each instrument type (A and B) were established according to the angle of insertion of the instruments inside the artificial canal (0°, 10° and 20°). The tests were performed using a custom-made device consisting of the following: a motor that can record torque values of 0.1 s; interchangeable stainless-steel canals with different curvature (0°, 10° and 20°) that allow the instrument’s angulated insertion and keep it flexed during testing procedures; and a vise used to secure the instrument at 3 mm from the tip. Torque limit was set to 5.5 Ncm, and each instrument was rotated at 500 rpm until fracture occurred. Torque to fracture (TtF) was registered by the endodontic motor, and the fragment length (FL) was measured with a digital caliper. Fractographic analysis was performed using a scanning electron microscopy (SEM) evaluation to confirm the cause of failure. TtF values and fragment length (FL) values were statistically analyzed using one-way analysis of variance (ANOVA) test and the Bonferroni correction for multiple comparisons across the groups with significance set to a 95% confidence level. Regarding the F-One Blue instruments, the results showed a higher TtF for group A3 (20°) than for group A1 (0°) and group A2 (10°), with a statistically significant difference between group A3 and the other two groups (p < 0.05), whereas no statistically significant difference was found between group A1 and group A2 (p > 0.05). Regarding the HeroShaper instrument, the results showed the highest TtF for group B3, with a statistically significant difference between the three subgroups B1, B2 and B3 (p < 0.05). The results showed that the torsional resistance increases as the angle of instrument access increases with a varying intensity, according to the crystallographic phase of the instrument selected.
Collapse
|
20
|
Zanza A, Seracchiani M, Di Nardo D, Reda R, Gambarini G, Testarelli L. A Paradigm Shift for Torsional Stiffness of Nickel-Titanium Rotary Instruments: A Finite Element Analysis. J Endod 2021; 47:1149-1156. [PMID: 33915175 DOI: 10.1016/j.joen.2021.04.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 03/16/2021] [Accepted: 04/14/2021] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The aim of this study was to investigate the influence of mass and the polar moment of inertia on the torsional behavior of nickel-titanium rotary instruments to understand which parameter of cross-sectional design had a key role in terms of torsional resistance. METHODS Four different instrument models were designed and meshed using computer-aided engineering software (SolidWorks; Dassault Systems, Waltham, MA). Instrument models shared the same characteristics, except for cross-sectional design; triangle, rectangle, square, and hollow square geometry was selected. Finite element analysis was performed simulating a static torsional test using the FEEPlus internal solver (Solid Works). Von Mises stress and torsional load at fracture were calculated by the software. Linear regression analysis was performed to investigate the relationship of the polar moment of inertia, cross-sectional area, inner core radius, and mass per volume on the torsional resistance of nickel-titanium rotary instruments. RESULTS The polar moment of inertia positively affected the maximum torsional load with the highest level of correlation (R2 = 0.917). It could be stated that the higher the polar moment of inertia is, the more maximum torsional load at fracture is present. Mass and cross-sectional area had a lower level of correlation compared with the polar moment of inertia (R2 = 0.5533). According to this, 2 instruments with the same mass/mm and/or cross-sectional area could have different torsional resistance. CONCLUSIONS The polar moment of inertia can be considered as the most important cross-sectional factor in determining the torsional resistance of rotary instruments over metal mass and cross-sectional area.
Collapse
Affiliation(s)
- Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Marco Seracchiani
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Dario Di Nardo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy.
| | - Rodolfo Reda
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Gianluca Gambarini
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
21
|
An Update of the Possible Applications of Magnetic Resonance Imaging (MRI) in Dentistry: A Literature Review. J Imaging 2021; 7:jimaging7050075. [PMID: 34460671 PMCID: PMC8321370 DOI: 10.3390/jimaging7050075] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 04/15/2021] [Accepted: 04/19/2021] [Indexed: 12/21/2022] Open
Abstract
This narrative review aims to evaluate the current evidence for the application of magnetic resonance imaging (MRI), a radiation-free diagnostic exam, in some fields of dentistry. BACKGROUND Radiographic imaging plays a significant role in current first and second level dental diagnostics and treatment planning. However, the main disadvantage is the high exposure to ionizing radiation for patients. METHODS A search for articles on dental MRI was performed using the PubMed electronic database, and 37 studies were included. Only some articles about endodontics, conservative dentistry, implantology, and oral and craniofacial surgery that best represented the aim of this study were selected. RESULTS All the included articles showed that MRI can obtain well-defined images, which can be applied in operative dentistry. CONCLUSIONS This review highlights the potential of MRI for diagnosis in dental clinical practice, without the risk of biological damage from continuous ionizing radiation exposure.
Collapse
|
22
|
Iacono F, Pirani C, Gatto MR, Prati C, Peters OA. Combining apical torsional load and cyclic fatigue resistance of NiTi instruments: New approach to determine the effective lifespan of rotary instruments. AUST ENDOD J 2021; 47:429-434. [PMID: 33650137 DOI: 10.1111/aej.12495] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 12/28/2020] [Accepted: 02/12/2021] [Indexed: 11/29/2022]
Abstract
In the described proof-of-principle experiments, we introduced a novel testing device to investigate how different concurrent torsional loads influence the cyclic fatigue (CF) resistance of a nickel-titanium (NiTi) instrument. The device was designed to test CF resistance of NiTi files with a standardized load on the apical 5 mm; a movable cylinder controlled by a lever provided a uniform real-time load. Thirty-three NiTi instruments 25.04 (F360, Komet, Lemgo, Germany) were rotated until fracture at 30° curvature under three different torsional loads (n = 11 each); Group A: 2.5 Ncm; Group B: 5 Ncm; Group C: 10 Ncm. anova, multiple comparisons Tamhane tests, regression and Kaplan-Meyer analysis were performed to contrast means. Resistance to cyclic fatigue differed significantly among groups (P = 0.0001). Increased torsional loads led to a decrease in time to failure. An inverse correlation (r = -0.721, P = 0.001) was observed between time and torsional load, with higher torsional loads correlated to shorter times to fracture.
Collapse
Affiliation(s)
- Francesco Iacono
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Chiara Pirani
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Maria Rosaria Gatto
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Carlo Prati
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Ove A Peters
- School of Dentistry, University of Queensland, Herston, Queensland, Australia.,University of the Pacific, Arthur A. Dugoni School of Dentistry, San Francisco, California, USA
| |
Collapse
|
23
|
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files. J Clin Med 2020; 9:jcm9113755. [PMID: 33233442 PMCID: PMC7700305 DOI: 10.3390/jcm9113755] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 11/20/2020] [Accepted: 11/20/2020] [Indexed: 11/19/2022] Open
Abstract
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 µm apical diameter, 60° curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
Collapse
|