1
|
Mocuta Bojoga DE, Grad Buriac O, Mateas M, Luca R, Carmen Todea D. Comparative Evaluation of Influence of Nd:YAG Laser (1064 nm) and 980 nm Diode Laser on Enamel around Orthodontic Brackets: An In Vitro Study. Medicina (Kaunas) 2022; 58:633. [PMID: 35630050 PMCID: PMC9145095 DOI: 10.3390/medicina58050633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/27/2022] [Accepted: 04/29/2022] [Indexed: 11/17/2022]
Abstract
(1) Background: The prevention of demineralizing lesions at the enamel structure level continues to represent a challenge in daily dental practice. When bacteria influence the pH level, this will decrease below the threshold for remineralization and the dissociation of hydroxyapatite will occur with a high percentage of phosphate and calcium loss. These elements continue to be studied by many authors in order to obtain a working protocol that will lead to their stabilization at the level of the enamel structure, thus preventing the demineralization process. The aim of this study is to evaluate and compare the influence of two types of laser wavelengths on the surface morphology and mineral components of the enamel through an examination with scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometry (EDX). (2) Methods: Thirty permanent human incisors extracted for periodontal reasons from patients aged 25−40 years old were selected for this study. Metallic brackets (SS Standard 022 Slot, OC Orthodontics, McMinnville, OR, 97128, USA) were bonded onto each tooth. The buccal surface was randomly assigned three sections: Section A—negative control (no treatment), section B—treated with 980 nm Gallium−Aluminum−Arsenide diode laser (a 300 µm optic fiber was used with 0.8 W output power, energy density of 5.33 J/mm2, in continuous mode, for 30 s, oriented perpendicularly to the enamel surface in contact mode) (KaVo GENTLEray 980 Diode Laser, Kaltenbach & Voigt GmbH, Biberach, Germany), and section C—treated with Nd:YAG laser (a 300 µm fiber was carried out at a 1 mm distance from the enamel surface with 0.75 W power, 75 mJ pulse energy, pulse repetition rate of 10 Hz, 5 J/mm2 fluency, average exposure time of 30 s, and water cooling assisted) (LIGHTWALKER AT S, M021-5AF/1 S, Fotona d.o.o, Ljubljana, Slovenia). The elements evaluated in this study were calcium (Ca), phosphate (P), oxygen (O), and carbon (C). A one-way analysis of variance, paired t-tests, and independent t-tests were carried out to evaluate the results using the SPSS 19 IBM Statistical package software for Microsoft. (3) Results: The evaluation of the data indicated that both wavelengths produced an increase in Ca wt% (for diode laser the mean of Ca wt% before irradiation was 21.06, while that after treatment reached 28.24; and for Nd:YAG laser, the mean of Ca wt% before irradiation was 21.31, while that after treatment reached 33.88); as well, the 980 nm diode laser decreased P wt% (from 17.20 before irradiation to 16.92 after irradiation) and the Nd:YAG laser increased P wt% (from 17.46 before irradiation to 18.28 after irradiation). These results showed a statistically significant difference at the p < 0.05 level. (4) Conclusions: It can be concluded that the best improvement of enamel chemical composition was obtained with Nd:YAG irradiation.
Collapse
Affiliation(s)
- Daliana-Emanuela Mocuta Bojoga
- Department of Oral Rehabilitation and Dental Emergencies, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy, 9 Revolutiei 1989 Avenue, 300070 Timisoara, Romania
- Interdisciplinary Research Center for Dental Medical Research, Lasers and Innovative Technologies, 9 Revolutiei 1989 Avenue, 300070 Timisoara, Romania
| | - Oana Grad Buriac
- Faculty of Industrial Chemistry and Environmental Engineering, Research Institute for Renewable Energy, Politehnica University of Timisoara, Piata Victoriei, 300006 Timisoara, Romania
| | - Marius Mateas
- Mechatronics Department, Polytechnic University of Timisoara, 1 Mihai Viteazu Avenue, 300006 Timisoara, Romania
| | - Ruxandra Luca
- Department of Oral Rehabilitation and Dental Emergencies, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy, 9 Revolutiei 1989 Avenue, 300070 Timisoara, Romania
- Interdisciplinary Research Center for Dental Medical Research, Lasers and Innovative Technologies, 9 Revolutiei 1989 Avenue, 300070 Timisoara, Romania
| | - Darinca Carmen Todea
- Department of Oral Rehabilitation and Dental Emergencies, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy, 9 Revolutiei 1989 Avenue, 300070 Timisoara, Romania
- Interdisciplinary Research Center for Dental Medical Research, Lasers and Innovative Technologies, 9 Revolutiei 1989 Avenue, 300070 Timisoara, Romania
| |
Collapse
|
2
|
Faus-Matoses V, Pérez García R, Faus-Llácer V, Faus-Matoses I, Alonso Ezpeleta Ó, Albaladejo Martínez A, Zubizarreta-Macho Á. Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files. Int J Environ Res Public Health 2022; 19:ijerph19074414. [PMID: 35410096 PMCID: PMC8998441 DOI: 10.3390/ijerph19074414] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 02/04/2023]
Abstract
In this study, we compare and analyze the scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), morphometry and cyclic fatigue resistance of Endogal, PathMax, and Smarttrack novel brands of nickel−titanium (NiTi) alloy endodontic files. Material and Methods: Thirty sterile NiTi endodontic rotary files were randomly selected and assigned to one of the following study groups: A: 25.08 F2 Endogal (EDG) (n = 10); B: 25.08 F2 Path Max Pro (PMP) (n = 10); and C: 25.06 Smarttrack (ST) (n = 10). Dynamic cyclic fatigue tests were conducted using a cyclic fatigue device in stainless steel artificial root canal systems with an apical diameter of 250 µm, curvature angle of 60°, radius of curvature of 3 mm, and taper of 6%. Additionally, we analyzed the NiTi endodontic rotary files using EDX, SEM, and morphometry after micro-CT scanning. The results were analyzed using Weibull statistical analysis and ANOVA testing. Results: SEM, EDX, and morphometric analyses showed differences between the three novel brands of NiTi endodontic rotary files. Moreover, statistically significant differences were observed between the number of cycles to failure and time to failure of the three novel brands of NiTi endodontic rotary files (p < 0.001). Conclusions: Smarttrack NiTi alloy endodontic reciprocating files display greater resistance to cyclic fatigue than Endogal and Path Max Pro NiTi alloy endodontic rotary files, due to the reciprocating movement and metallurgical composition.
Collapse
Affiliation(s)
- Vicente Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Raúl Pérez García
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Vicente Faus-Llácer
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
| | - Ignacio Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain; (V.F.-M.); (R.P.G.); (V.F.-L.)
- Correspondence:
| | - Óscar Alonso Ezpeleta
- Department of Endodontics, School of Health Sciences, University of Zaragoza, 22006 Zaragoza, Spain;
| | - Alberto Albaladejo Martínez
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain; (A.A.M.); or (Á.Z.-M.)
| | - Álvaro Zubizarreta-Macho
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain; (A.A.M.); or (Á.Z.-M.)
- Department of Endodontics, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain
| |
Collapse
|
3
|
Faus-Llácer V, Hamoud-Kharrat N, Marhuenda Ramos MT, Faus-Matoses I, Zubizarreta-Macho Á, Ruiz Sánchez C, Faus-Matoses V. Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files-An In Vitro Study. J Clin Med 2021; 10:4713. [PMID: 34682836 DOI: 10.3390/jcm10204713] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/07/2021] [Accepted: 10/11/2021] [Indexed: 11/21/2022] Open
Abstract
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10); B: 20.04 rectangular cross-section NiTi alloy endodontic rotary files (T Pro E1) (n = 10); C: 25.04 convex triangular cross-section NiTi alloy endodontic rotary files (T Pro E2) (n = 10); and D: 25.06 triangular cross-section NiTi alloy endodontic rotary files (T Pro E4) (n = 10). A cyclic fatigue device was used to conduct the static cyclic fatigue tests with stainless steel artificial root canal systems with 200 µm and 250 µm apical diameter, 60° curvature angle, 3 mm radius of curvature, 20 mm length, and 4% and 8% taper. The results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All the pairwise comparisons presented statistically significant differences between the time to failure and number of cycles to failure for the cross-section design study groups (p < 0.001). Conclusions: the double S-shaped cross-section of Mtwo NiTi endodontic files shows higher cyclic fatigue resistance than the rectangular cross-section of T Pro E1 NiTi endodontic files, the convex triangular cross-section of T Pro E2 NiTi endodontic files, and the triangular cross-section of T Pro E4 NiTi endodontic files.
Collapse
|
4
|
Grazziotin-Soares R, Nekoofar MH, Davies TE, Bafail A, Alhaddar E, Hübler R, Busato ALS, Dummer PMH. Effect of bismuth oxide on white mineral trioxide aggregate: chemical characterization and physical properties. Int Endod J 2013; 47:520-33. [PMID: 24025109 DOI: 10.1111/iej.12181] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2013] [Accepted: 07/31/2013] [Indexed: 11/29/2022]
Abstract
AIM To assess the effect of bismuth oxide (Bi2 O3 ) on the chemical characterization and physical properties of White mineral trioxide aggregate (MTA) Angelus. METHODOLOGY Commercially available White MTA Angelus and White MTA Angelus without Bi2 O3 provided by the manufacturer especially for this study were subjected to the following tests: Rietveld X-ray diffraction analysis (XRD), energy-dispersive X-ray analysis (EDX), scanning electron microscopy (SEM), compressive strength, Vickers microhardness test and setting time. Chemical analysis data were reported descriptively, and physical properties were expressed as means and standard deviations. Data were analysed using Student's t-test and Mann-Whitney U test (P = 0.05). RESULTS Calcium silicate peaks were reduced in the diffractograms of both hydrated materials. Bismuth particles were found on the surface of White MTA Angelus, and a greater amount of particles characterized as calcium hydroxide was observed by visual examination on White MTA without Bi2 O3 . The material without Bi2 O3 had the shortest final setting time (38.33 min, P = 0.002), the highest Vickers microhardness mean value (72.35 MPa, P = 0.000) and similar compressive strength results (P = 0.329) when compared with the commercially available White MTA Angelus containing Bi2 O3 . CONCLUSION The lack of Bi2 O3 was associated with an increase in Vickers microhardness, a reduction in final setting time, absence of Bi2 O3 peaks in diffractograms, as well as a large amount of calcium and a morphology characteristic of calcium hydroxide in EDX/SEM analysis.
Collapse
|