1
|
Migliorini F, Cocconi F, Schipper I, Ten Duis K, Marzi I, Komadina R, Hildebrand F, Wendt K. Arterial angioembolisation versus pre-peritoneal pelvic packing in haemodynamically unstable patients with complex pelvic fractures: a meta-analysis. Eur J Trauma Emerg Surg 2024; 50:1295-1304. [PMID: 37962595 PMCID: PMC11458644 DOI: 10.1007/s00068-023-02389-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/23/2023] [Indexed: 11/15/2023]
Abstract
INTRODUCTION Angioembolisation (AE) and/or pre-peritoneal pelvic packing (PPP) may be necessary for patients with complex pelvic fractures who are haemodynamically unstable. However, it remains unclear whether AE or PPP should be performed as an initial intervention and ongoing debates exist. This meta-analysis aimed to compare AE versus PPP in haemodynamically unstable patients with acute pelvic fractures. The primary outcomes of interest were to compare in-hospital mortality rate and number of blood units transfused. Secondary outcomes included evaluating differences in the time from diagnosis to treatment, as well as the length of stay in the intensive care unit (ICU) and hospital. METHODS All clinically relevant studies comparing AE versus PPP in patients with complex pelvic fractures and haemodynamic instability were accessed. The 2020 PRISMA guidelines were followed. In September 2023, the following databases were accessed: PubMed, Web of Science, Google Scholar and Embase, without constraint. RESULTS Data from 320 patients were collected (AE: 174; PPP: 146). The mean age on admission was 47.4 ± 7.2 years. The mean Injury Severity Score (ISS) on admission was 43.5 + 5.4 points. Baseline comparability was observed in ISS (P = 0.5, Table 3) and mean age (P = 0.7, Table 3). No difference was reported in mortality rate (P = 0.2) or rate of blood units transfused (P = 0.3). AE had a longer mean time to the procedure of 44.6 min compared to PPP (P = 0.04). The mean length of ICU and hospital stay were similar in both groups. CONCLUSION Despite the longer mean time from admission to the procedure, no significant differences were found between AE and PPP in terms of in-hospital mortality, blood units transfused, or length of ICU, and hospital stay. These findings should be interpreted considering the limitations of the present study. High-quality comparative research is strongly warranted. LEVEL OF EVIDENCE Level IV, meta-analysis.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedics, Trauma and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy.
| | - Federico Cocconi
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy
| | - Inger Schipper
- Department of Orthopaedic and Trauma Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Kaj Ten Duis
- Department of Orthopaedic and Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Ingo Marzi
- Department of Orthopaedic and Trauma Surgery, University Hospital Frankfurt, Goethe University, Frankfurt, Germany
| | - Radko Komadina
- Department of Orthopaedic and Trauma Surgery, Medical Faculty, University of Ljubljana, Ljubljana, Slovenia
| | - Frank Hildebrand
- Department of Orthopaedics, Trauma and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Klaus Wendt
- Department of Orthopaedic and Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
2
|
Jordan MC, Fuchs KF, Herath SC, Windolf J, Meffert RH, Neubert A. Do we need another screw? Sacroiliac screw fixation in open-book pelvic ring injuries (APC type II). EFORT Open Rev 2024; 9:827-836. [PMID: 39087500 PMCID: PMC11370719 DOI: 10.1530/eor-23-0173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/02/2024] Open
Abstract
Purpose To compare anterior plate fixation (SP fixation) both alone and in combination with an additional posterior sacroiliac screw (SP+SIS fixation) as a treatment for pelvic ring injuries with widening of the pubic symphysis and disruption to the anterior sacroiliac ligaments. Methods To find studies with pelvic ring injuries (APC II; B2.3d) and SP or SP+SIS fixation, a systematic literature review was conducted by searching four databases. A protocol was published a priori at Open Science Framework (https://doi.org/10.17605/OSF.IO/3YHAV). Exclusion criteria included perineal injuries, chronic instability of the symphysis, complete sacroiliac separation, and pediatric patients (age <18 years). Primary outcomes of interest were defined as implant failure, health-related quality of life, and revision rate. Results Altogether, 1861 studies were screened, and 40 studies qualified for full-text analysis. In total, 14 studies (two surveys, six biomechanical studies, and six retrospective clinical studies) were included. The surveys revealed that surgeons who had more recently begun practicing were more likely to use posterior fixation (SP+ISS). The biomechanical studies were heterogenous and did not yield a uniform pattern. In clinical studies, 117 patients (45%) received SP fixation, and 142 patients (55%) received SP+SIS fixation. Complications occurred in 31 SP patients (30%) and in five SP+SIS patients (3.5%). Conclusion A high risk of bias was uncovered, and reporting was found to be incomplete. SP+SIS may have the potential to improve outcomes, but the evidence remains too inconclusive to draw reliable recommendations.
Collapse
Affiliation(s)
- Martin C Jordan
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Würzburg, Germany
- TraumaEvidence @ German Society for Trauma Surgery, Berlin, Germany
| | - Konrad F Fuchs
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Würzburg, Germany
| | - Steven C Herath
- Department for Traumatology and Reconstructive Surgery, BG Trauma Center, University of Tübingen, Tübingen, Germany
| | - Joachim Windolf
- TraumaEvidence @ German Society for Trauma Surgery, Berlin, Germany
- Department of Orthopaedic and Traumatology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Rainer H Meffert
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Würzburg, Germany
| | - Anne Neubert
- TraumaEvidence @ German Society for Trauma Surgery, Berlin, Germany
- Department of Orthopaedic and Traumatology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
3
|
Notov D, Knorr E, Spiegl UJA, Osterhoff G, Höch A, Kleber C, Pieroh P. The clinical relevance of fixation failure after pubic symphysis plating for anterior pelvic ring injuries: an observational cohort study with long-term follow-up. Patient Saf Surg 2024; 18:17. [PMID: 38778372 PMCID: PMC11112942 DOI: 10.1186/s13037-024-00401-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 05/09/2024] [Indexed: 05/25/2024] Open
Abstract
BACKGROUND Open reduction and plate fixation is a standard procedure for treating traumatic symphyseal disruptions, but has a high incidence of implant failure. Several studies have attempted to identify predictors for implant failure and discussed its impact on functional outcome presenting conflicting results. Therefore, this study aimed to identify predictors of implant failure and to investigate the impact of implant failure on pain and functional outcome. METHODS In a single-center, retrospective, observational non-controlled cohort study in a level-1 trauma center from January 1, 2006, to December 31, 2017, 42 patients with a plate fixation of a traumatic symphyseal disruption aged ≥ 18 years with a minimum follow-up of 12 months were included. The following parameters were examined in terms of effect on occurrence of implant failure: age, body mass index (BMI), injury severity score (ISS), polytrauma, time to definitive treatment, postoperative weight-bearing, the occurrence of a surgical site infection, fracture severity, type of posterior injury, anterior and posterior fixation. A total of 25/42 patients consented to attend the follow- up examination, where pain was assessed using the Numerical Rating Scale and functional outcome using the Majeed Pelvic Score. RESULTS Sixteen patients had an anterior implant failure (16/42; 37%). None of the parameters studied were predictive for implant failure. The median follow-up time was six years and 8/25 patients had implant failure. There was no difference in the Numerical Rating Scale, but the work-adjusted Majeed Pelvic Score showed a better outcome for patients with implant failure. CONCLUSION implant failure after symphyseal disruptions is not predictable, but appears to be clinically irrelevant. Therefore, an additional sacroiliac screw to prevent implant failure should be critically discussed and plate removal should be avoided in asymptomatic patients.
Collapse
Affiliation(s)
- Dmitry Notov
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany.
| | - Eva Knorr
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Ulrich J A Spiegl
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
- Clinic for Trauma Surgery and Orthopaedics, Munich Harlaching, Sanatoriumspl. 2, 81545, München, Germany
| | - Georg Osterhoff
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Andreas Höch
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Christian Kleber
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| | - Philipp Pieroh
- Department of Orthopedics, Trauma and Plastic Surgery, University of Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany
| |
Collapse
|
4
|
陈 志, 李 强, 刘 瑞, 郭 浩, 唐 佩, 陈 华. [Research progress of pubic symphysis diastasis]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2023; 37:1541-1547. [PMID: 38130199 PMCID: PMC10739657 DOI: 10.7507/1002-1892.202306093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 11/09/2023] [Indexed: 12/23/2023]
Abstract
Objective To review the research progress of pubic symphysis diastasis and provide effective reference for orthopedic surgeons in the diagnosis and treatment of pubic symphysis diastasis. Methods The anatomy, injury mechanism, treatment, and other aspects of pubic symphysis diastasis were summarized and analyzed by reviewing the relevant research literature at domestically and internationally in recent years. Results The incidence of pubic symphysis diastasis is high in pelvic fractures, which is caused by the injury of the ligaments and fibrocartilage disc around the pubic symphysis by external force. The treatment plan should be individualized according to the pelvic stability and the needs of patients, aiming to restore the stability and integrity of the pelvis and improve the quality of life of patients after surgery. Conclusion At present, the research on pubic symphysis diastasis still needs to be improved. In the future, high-quality, multi-center, and large-sample studies are of great significance for the selection of treatment methods and the evaluation of effectiveness for patients with pubic symphysis diastasis.
Collapse
Affiliation(s)
- 志广 陈
- 内蒙古医科大学第一临床医学院(呼和浩特 010000)First Clinical Medical College, Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
| | - 强 李
- 内蒙古医科大学第一临床医学院(呼和浩特 010000)First Clinical Medical College, Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
| | - 瑞 刘
- 内蒙古医科大学第一临床医学院(呼和浩特 010000)First Clinical Medical College, Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
| | - 浩 郭
- 内蒙古医科大学第一临床医学院(呼和浩特 010000)First Clinical Medical College, Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
- 内蒙古医科大学附属医院骨科(呼和浩特 010000)Department of Orthopaedic Surgery, the Affiliated Hospital of Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
| | - 佩福 唐
- 内蒙古医科大学第一临床医学院(呼和浩特 010000)First Clinical Medical College, Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
| | - 华 陈
- 内蒙古医科大学第一临床医学院(呼和浩特 010000)First Clinical Medical College, Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
- 内蒙古医科大学附属医院骨科(呼和浩特 010000)Department of Orthopaedic Surgery, the Affiliated Hospital of Inner Mongolia Medical University, Hohhot Inner Mongolia, 010000, P. R. China
| |
Collapse
|
5
|
Kułakowski M, Elster K, Reichert P, Królikowska A, Jerominko J, Ślęczka P, Grzonkowska M, Szpinda M, Baumgart M. Anatomy of the sacroiliac joint with relation to the lumbosacral trunk: Is there sufficient space for a two-hole plate? PLoS One 2023; 18:e0292620. [PMID: 37856449 PMCID: PMC10586703 DOI: 10.1371/journal.pone.0292620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 09/25/2023] [Indexed: 10/21/2023] Open
Abstract
Dislocations of the sacroiliac joint (SIJ) are treated with iliosacral screws or anterior plating. The study aimed to investigate the course of the lumbosacral trunk with reference to SIJ and determine whether is there sufficient space for two screws through the sacrum while performing anterior plating. Sixty patients, who underwent an MRI of the lumbar spine were included in our study. The three transverse LT-SIJ distances were measured at the three points (A, B, and C). We also analyzed 60 CT pelvic scans at points A, B, and C in order to measure: the vertebral canal-to-SIJ distance, the sacrum's pelvic-to-dorsal surface sagittal distance, and the median plane-to-SIJ angle. The mean transverse LT-SIJ distances at points A, B, and C were 20.0 ± 3.05 mm, 17.9 ± 3.20 mm, and 12.3 ± 2.49 mm, respectively. Based on CT analyses, the vertebral canal-to-SIJ distances were 30.5 ± 7.65 mm at point A, 21.4 ± 5.05 mm at point B and 15.7 ± 6.05 mm at point C. The sacrum's pelvic-to-dorsal surface sagittal distances reached values: 35.1 ± 11.62 mm at point A, 52.5 ± 10.58 mm at point B, and 57.5 ± 7.79 mm at point C. The median plane-to-SIJ angles measured 31.4 ± 4.82 degrees at point A, 26.6 ± 3.77 degrees at point B and 21.3 ± 3.25 mm at point C. Proximally, the safe zone for applying an anterior plate of SIJ is 20.0 mm. Since both the safe zone and safe corridor taper distally, surgeons may securely use one screw of gradually increased length towards the distal direction of SIJ, with inclination of 30 degrees in relation to the median plane of the lesser pelvis.
Collapse
Affiliation(s)
- Michał Kułakowski
- Orthopaedic and Trauma Surgery Department, Independent Public Healthcare Center Rypin, Rypin, Poland
| | - Karol Elster
- Orthopaedic and Trauma Surgery Department, Independent Public Healthcare Center Rypin, Rypin, Poland
| | - Paweł Reichert
- Clinical Department of Trauma and Hand Surgery, Jan Mikulicz-Radecki University Clinical Hospital in Wroclaw, Wroclaw, Poland
| | - Aleksandra Królikowska
- Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, Wroclaw, Poland
| | - Joanna Jerominko
- Department of Radiology, Franciszek Lukaszczyk Oncology Center, Bydgoszcz, Poland
| | - Paweł Ślęczka
- Orthopaedic and Trauma Surgery Department, Independent Public Healthcare Center Myślenice, Myślenice, Poland
| | - Magdalena Grzonkowska
- Department of Normal Anatomy, The Ludwik Rydygier Collegium Medicum in Bydgoszcz, The Nicolaus Copernicus University in Toruń, Toruń, Poland
| | - Michał Szpinda
- Department of Normal Anatomy, The Ludwik Rydygier Collegium Medicum in Bydgoszcz, The Nicolaus Copernicus University in Toruń, Toruń, Poland
| | - Mariusz Baumgart
- Department of Normal Anatomy, The Ludwik Rydygier Collegium Medicum in Bydgoszcz, The Nicolaus Copernicus University in Toruń, Toruń, Poland
| |
Collapse
|
6
|
Tseng KY, Lin KC, Yang SW. The radiographic outcome after plating for pubic symphysis diastasis: does it matter clinically? Arch Orthop Trauma Surg 2023; 143:1965-1972. [PMID: 35278092 PMCID: PMC10030392 DOI: 10.1007/s00402-022-04411-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 02/26/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Open reduction and internal fixation with plates is the most widespread surgery in traumatic pubic symphysis diastasis. However, implant failure or recurrent diastasis was commonly observed during follow-up. The aim of our study was to evaluate the radiologic findings and clinical outcomes. MATERIALS AND METHODS Sixty-five patients with traumatic pubic symphysis diastasis treated with plating between 2008 and 2019 were retrospectively reviewed. The exclusion criteria were a history of malignancy and age under 20 years. Radiographic outcomes were determined by radiograph findings, including pubic symphysis distance (PSD) and implant failure. Clinical outcomes were assessed according to the Majeed score at the final follow-up. RESULTS Twenty-eight patients were finally included. Nine patients (32%) experienced implant failure, including four (14%) with screw loosening and five (18%) with plate breakage. Only one patient underwent revision surgery. Postoperatively, a significant increase in PSD was observed at 3 months and 6 months. Postoperative PSD was not significantly different between patients with single plating and double plating, but it was significantly greater in the implant-failure group than in the non-failure group. The Majeed score was similar between patients with single plating and double plating or between the implant-failure group and the non-failure group. Body mass index, number of plates, age, and initial injured PSD were not significantly different between the implant-failure group and the non-failure group. Only a significant male predominance was observed in the implant-failure group. CONCLUSION A gradual increase in the symphysis distance and a high possibility of implant failure may be the distinguishing features of traumatic pubic symphysis diastasis fixation. The postoperative symphyseal distance achieved stability after 6 months, even after implant failure. Radiographic outcomes, such as increased symphysis distance, screw loosening, and plate breakage, did not affect clinical functional outcomes.
Collapse
Affiliation(s)
- Kuo-Yuan Tseng
- Department of Orthopedics, Kaohsiung Veterans General Hospital, 386 Ta-Chung 1st Road, Kaohsiung, 81346, Taiwan
| | - Kai-Cheng Lin
- Department of Orthopedics, Kaohsiung Veterans General Hospital, 386 Ta-Chung 1st Road, Kaohsiung, 81346, Taiwan
| | - Shan-Wei Yang
- Department of Orthopedics, Kaohsiung Veterans General Hospital, 386 Ta-Chung 1st Road, Kaohsiung, 81346, Taiwan.
| |
Collapse
|
7
|
Poole WEC, Neilly DW, Rickman MS. Is unrestricted weight bearing immediately after fixation of rotationally unstable pelvic fractures safe? BMC Musculoskelet Disord 2022; 23:348. [PMID: 35410267 PMCID: PMC8996606 DOI: 10.1186/s12891-022-05299-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 03/23/2022] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION Rotationally unstable pelvic fractures treated with surgical fixation have traditionally been treated with restricted weight bearing on the affected side for 6-8 weeks post operatively. We have been developing pelvic fixation standards to allow for unrestricted weight bearing immediately post operatively in type B rotationally unstable pelvic fractures. AIMS To assess for safety and efficacy of allowing unrestrictive weight bearing in this cohort of patients, we have clinically and radiologically monitored outcomes up to two years post operatively. METHODS Through retrospective review, two cohorts of patients with Tile Type B pelvic fractures were identified that were treated at the Royal Adelaide Hospital, South Australia. Patient demographics, injury classification, surgical fixation and weight bearing status post operatively was recorded. One cohort of patients was allowed to fully weight bear post operatively, whilst the other was treated with 6 weeks of restricted post op weight bearing. At clinical follow up, post-operative x-rays were assessed for loss of reduction, screw or plate breakage and reoperation. RESULTS Between January 2018 and January 2021, 53 patients with rotationally unstable pelvic fractures that underwent surgical fixation were included in this study. One group of patents were allowed to immediately weight bear as tolerated (WBAT) post operatively (n = 28) and the other with restricted weightbearing (RWB) (n = 25). There was 1 re operation for failure of fixation in each group. Metalwork breakage was more common in the WBAT group than in the RWB group and this was seen only in APC fractures. This increase in metalwork failure was not associated with loss of reduction. CONCLUSIONS With surgical fixation, Tile type B rotationally unstable pelvic fractures can be allowed immediate weight bearing post operatively. We found this to be safe and effective, employing surgical strategies to address both anterior and posterior injuries to allow immediate unrestricted weight bearing. Broken metalwork was more commonly seen in the WBAT group but this was not associated with loss of reduction or reoperation.
Collapse
Affiliation(s)
- William E C Poole
- Orthopaedic Trauma Department, Royal Adelaide Hospital, Adelaide, Australia.
| | - David W Neilly
- Orthopaedic Trauma Department, Royal Adelaide Hospital, Adelaide, Australia
| | - Mark S Rickman
- Orthopaedic Trauma Department, Royal Adelaide Hospital, Adelaide, Australia.,Trauma & Orthopaedics, University of Adelaide, Adelaide, Australia
| |
Collapse
|
8
|
Can locking plate fixation of symphyseal disruptions allow early weight bearing? Injury 2021; 52:2725-2729. [PMID: 32107009 DOI: 10.1016/j.injury.2020.02.094] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 02/05/2020] [Accepted: 02/17/2020] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Anterior pubic symphyseal plate fixation is the recommended treatment for disruption of pubic symphysis in an unstable pelvic ring injury. The rigid construct offered by locking symphyseal plate has the theoretical advantage of allowing patients to weight bear early. However, there are concerns of catastrophic failure about the locked plate construct. The purpose of the study was to establish if locking plate fixation for pubic symphysis disruption was effective to allow patients to mobilise weight bearing immediately after surgery. PATIENT AND METHODS Retrospective analysis of a prospectively collected database from a single centre was performed. The study period was from 2008 to 2017. Radiographic evidence of fixation failure, revision surgery, removal of metalwork and follow up duration was noted. RESULTS We identified 46 patients (F:M 8:38) with a mean age of 46 years (range 14 to 74 years). Based on the mechanism of injury patients were classified into Antero-posterior compression (28), Vertical shear [10], lateral compression [4] and combined mechanism [4]. Either a 4-hole or 6-hole locking plate was used in all patients, depending on fracture extension. Posterior fixation was required in 28 (61%) patients. All patients were allowed to fully or partial weight bear. The mean radiological follow-up period was 31 weeks with 13 (28%) patients having evidence of radiological failure. Revision was performed in 1 (2%) patient, in whom the screws had pulled out of the bone. The most common mode of failure was either the screw backing out from the plate or broken screw. Among the 4 (8%) patients who had their metalwork removed, 1 (2%) had delayed onset of infection, 2 (4%) had symptoms related to backed out screw and 1 (2%) opted electively to have metalwork removed. CONCLUSIONS With our series of patients, we have found that using locking plate for pubic symphyseal diastasis is safe and effective in allowing patients to weight bear early. A low complication rate and need for re-operation is demonstrated.
Collapse
|
9
|
Murena L, Canton G, Hoxhaj B, Sborgia A, Fattori R, Gulli S, Vaienti E. Early weight bearing in acetabular and pelvic fractures. ACTA BIO-MEDICA : ATENEI PARMENSIS 2021; 92:e2021236. [PMID: 34487095 PMCID: PMC8477081 DOI: 10.23750/abm.v92i4.10787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Accepted: 11/03/2020] [Indexed: 11/23/2022]
Abstract
Background and aim of the work: The incidence of pelvic and acetabular fractures is increasing during the years, counting 37 pelvic fractures per 100000 people annually. No weight bearing or toe touch weight bearing are usually chosen in the initial management to allow fracture and ligamentous healing and avoid fracture displacement and fixation failure. On the other hand, early weight bearing may stimulate fracture healing and allow prompt functional recovery, faster return to work and recreational activities and reduce complications linked to late rehabilitation. Aim of the study is to review the literature about weight bearing indications for pelvic and acetabular fractures to highlight clinical and biomechanical evidence supporting early weight bearing. Methods: Two independent reviewers independently extracted studies on early weight bearing of pelvic and acetabular fractures. All selected studies were screened independently based on title and abstract. Then the full text of any article that either judged potentially eligible was acquired and reviewed again. Any disagreement was resolved by discussing the full text manuscripts. Results: 44 studies including reviews, meta-analysis, clinical and biomechanical studies were selected. Conclusions: Despite biomechanical data, few clinical evidences can be found to support early weight bearing in pelvic and especially acetabular fractures treatment. The promising results of some clinical experiences, however, should direct further studies to clearly define the indications and limits of early weight bearing in these injuries. Recognizing intrinsic lesion stability and bone and fixation technique quality, together with patient age and compliance, should be the mainstay for post-operative management choice. (www.actabiomedica.it)
Collapse
Affiliation(s)
- Luigi Murena
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUGI, Department of Medical, Surgical and Life Sciences, Trieste University, Trieste (Italy)..
| | - Gianluca Canton
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUGI, Department of Medical, Surgical and Life Sciences, Trieste University, Trieste (Italy)..
| | | | - Andrea Sborgia
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUGI, Department of Medical, Surgical and Life Sciences, Trieste University, Trieste (Italy)..
| | - Roberto Fattori
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUGI, Department of Medical, Surgical and Life Sciences, Trieste University, Trieste (Italy)..
| | - Stefano Gulli
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUGI, Department of Medical, Surgical and Life Sciences, Trieste University, Trieste (Italy)..
| | - Enrico Vaienti
- Orthopaedics and Traumatology Clinic, Department of Medicine and Surgery, University of Parma (Italy)..
| |
Collapse
|
10
|
Jordan MC, Jäckle V, Scheidt S, Gilbert F, Hölscher-Doht S, Ergün S, Meffert RH, Heintel TM. Trans-obturator cable fixation of open book pelvic injuries. Sci Rep 2021; 11:13463. [PMID: 34188088 PMCID: PMC8241833 DOI: 10.1038/s41598-021-92755-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 06/15/2021] [Indexed: 01/13/2023] Open
Abstract
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
Collapse
Affiliation(s)
- Martin C Jordan
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
| | - Veronika Jäckle
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Sebastian Scheidt
- Department of Orthopaedic Surgery, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Fabian Gilbert
- Department of Orthopedics, Physical Medicine and Rehabilitation, University Hospital LMU München, Marchioninistr. 15, 81377, München, Germany
| | - Stefanie Hölscher-Doht
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Süleyman Ergün
- Institute of Anatomy, Julius-Maximilians-University Würzburg, Koellikerstraße 6, 97070, Würzburg, Germany
| | - Rainer H Meffert
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Timo M Heintel
- Department of Orthopaedic Traumatology, University Hospital Würzburg, Julius-Maximilians-University Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| |
Collapse
|
11
|
Barrientos-Mendoza C, Brañes J, Wulf R, Kremer A, Barahona M, León S. The role of anterior supra-acetabular external fixator as definitive treatment for anterior ring fixation in unstable pelvic fractures. Eur J Trauma Emerg Surg 2021; 48:3737-3746. [PMID: 34097076 DOI: 10.1007/s00068-021-01711-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 05/25/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Management of anterior ring injuries is still a matter of discussion, and there are only few studies reporting anterior external fixator as definitive treatment for unstable pelvic injuries. This study aimed to describe the clinical and radiological outcomes of a consecutive series of mechanically unstable pelvic injuries that were treated with definitive anterior supra-acetabular external fixator for the anterior ring, and to identify risk factors for failure. METHODS We included a consecutive series of patients with unstable pelvic ring fractures who underwent anterior supra-acetabular external fixation for definitive treatment, between January 2012 and January 2020. All demographics, associated injuries and procedures, injury mechanism, and complications were analysed. Pelvic fracture was classified based on Orthopaedic Trauma Association/Tile AO (OTA/AO) and Young-Burgess classifications. Complications associated with the external fixator were revised. All patients were functionally evaluated at final follow-up and asked to report their clinical outcomes using the Majeed score. RESULTS A total of 47 patients were included, of which 25 were females. The median age was 44 years (interquartile range 23-59). Median follow-up duration was 14 months (interquartile range 6-31). The most frequent aetiology was motor vehicle accident (35), followed by fall from height (8). All fractures required posterior pelvic ring fixation. The median time during which patients had external fixation in situ was 11 weeks (interquartile range 9-13). All patients achieved healing of pelvic fracture at median time of 10 weeks (interquartile range 8-12). At final follow-up, the median displacement of the anterior pelvis was 6 mm (interquartile range 0-11). Superficial infection was the most common complication (n = 7). No washout procedures were needed. No major complication was reported. No patient required reoperation for anterior ring fracture. The median Majeed score was 88 points (range 60-95; interquartile range 80-90) at final follow-up. CONCLUSION Our findings suggest that the use of supra-acetabular external fixator is safe and effective for definitive treatment of the anterior ring in unstable pelvic fractures. It is a method with high proportion of excellent results, regardless of the type of fracture. The rate of complications is low, and it does not compromise functional results.
Collapse
Affiliation(s)
- Cristián Barrientos-Mendoza
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile. .,Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile. .,Orthopaedics Department, Hip and Pelvis Unit, Clínica Santa María, Santiago, Chile.
| | - Julián Brañes
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile.,Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| | - Rodrigo Wulf
- Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| | - Alex Kremer
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile
| | - Maximiliano Barahona
- Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| | - Sebastián León
- Orthopaedics Department, Hospital San José, San Jose 1196, 8380219, Santiago, Region Metropolitana, Chile.,Orthopaedics Department, Hospital Clínico de La Universidad de Chile, Santiago, Chile
| |
Collapse
|
12
|
The arterial blood supply of the symphysis pubis - Spatial orientated and highly variable. Ann Anat 2020; 234:151649. [PMID: 33227373 DOI: 10.1016/j.aanat.2020.151649] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 10/19/2020] [Accepted: 11/02/2020] [Indexed: 11/21/2022]
Abstract
BACKGROUND Open surgical treatment of the pubic region and adductor related pathologies require an exact knowledge of the arterial blood supply of the symphysis pubis that seems furthermore important to explain the hematogenous occurrence of symphysitis. Pubic bone marrow oedema (PBME) is a frequent occurring magnetic resonance imaging finding in groin pain. However, even asymptomatic athletes present PBME and a correlation to the physical activity or higher blood flow was suggested. Data on the vascular anatomy of the symphysis pubis are rare. METHODS Ten formaldehyde-embalmed cadavers were dissected, and the arterial blood supply was investigated and photographically documented. RESULTS In the majority of cases the following pattern was determined: superior-inferior epigastric artery (n=12 hemipelves), inferior - dorsal artery of the penis/dorsal artery of the clitoris (n=16), posterior- obturator artery (n=16 hemipelves), anterior- deep external pudendal artery (n=14 hemipelves). Besides variations for the deep external pudendal artery anteriorly, we observed a highly variable arterial supply, especially superior. Superior in 4/10 cadavers, inferior in 0/10 cadavers, posterior in 2/10 cadavers and anterior in 5/10 cadavers side variations were found. CONCLUSION The symphysis pubis has a spatial and rich organized arterial blood supply with several variations. Despite the symphysis pubis is recognized as bradytroph, the high number of vessels is presumably required in stress situations for example in heavy training.
Collapse
|
13
|
Jordan MC, Jäckle V, Scheidt S, Eden L, Gilbert F, Heintel TM, Jansen H, Meffert RH. [Outcome after plate stabilization of symphyseal diastasis]. Unfallchirurg 2020; 123:870-878. [PMID: 32347368 PMCID: PMC7653790 DOI: 10.1007/s00113-020-00804-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Hintergrund Die Symphysensprengung mit entsprechender Diastase kann durch eine Symphysenplatte stabilisiert werden. Fragestellung Welche Beckenverletzungen werden mit einer Symphysenplatte stabilisiert und wie ist das Outcome? Material und Methoden Retrospektive Auswertung von 64 Patienten über einen Untersuchungszeitraum von 24 Monaten. Ergebnisse Es waren 56 Patienten männlich, 8 weiblich und das mittlere Alter betrug 44 Jahre (SD ± 17). Unfälle im Straßenverkehr waren der führende Grund für die Beckenverletzung. Die Verteilung nach AO-Klassifikation zeigte sich wie folgt: 14-mal B1-, 10-mal B2-, 5‑mal B3-, 23-mal C1-, 9‑mal C2- und 3‑mal C3-Verletzungen. Die Verteilung nach Young und Burgess ergab: 9‑mal APC-I-, 18-mal APC-II-, 13-mal APC-III-, 9‑mal LC-I-, 3‑mal LC-II-, 2‑mal LC-III- und 10-mal VS-Verletzungen. Der mittlere Injury Severity Score (ISS) betrug 32 und die mittlere stationäre Verweildauer 29 Tage (pos. Korrelation p ≤ 0,001). Im Verlauf war eine radiologische Implantatlockerung bei 52 Patienten nachweisbar. Therapierelevante Komplikationen gab es in 14 Fällen. Hierbei war das Implantatversagen (n = 8) der Hauptgrund für eine operative Revision. Diskussion Obwohl die radiologische Implantatlockerung häufig beobachtet wird, ist sie nur selten Grund für einen Revisionseingriff. Kommt es hingegen zum vollständigen Implantatversagen, tritt dies meist innerhalb der ersten postoperativen Wochen auf und ist revisionsbedürftig. Eine frühzeitige Abklärung durch Röntgenbildgebung sollte bei Verdacht erfolgen.
Collapse
Affiliation(s)
- Martin C Jordan
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland.
| | - Veronika Jäckle
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Sebastian Scheidt
- Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Bonn, Venusberg-Campus 1, 53127, Bonn, Deutschland
| | - Lars Eden
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Fabian Gilbert
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Timo M Heintel
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Hendrik Jansen
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| | - Rainer H Meffert
- Klinik und Poliklinik für Unfall‑, Hand‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Würzburg, Oberdürrbacher Straße 8, 97080, Würzburg, Deutschland
| |
Collapse
|
14
|
Beder FK, Hamdy MS, El-Desouky II, Abdelkader KF, Abdelazeem AH. Symphyseal plate with trans-symphyseal cross-screws for fixation of tile-type B1 pelvic ring injuries: radiological and functional evaluation. INTERNATIONAL ORTHOPAEDICS 2020; 44:2745-2751. [PMID: 33057743 DOI: 10.1007/s00264-020-04851-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Accepted: 10/09/2020] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Failure to neutralize the different physiological forces acting on the inferior as well as the superior regions of the pubic symphysis, the long healing time, is blamed for the repeated failures of conventional superior symphyseal plating. MATERIAL AND METHODS A three years prospective case series study between January 2017 and December 2019 was done, to evaluate the radiological and the functional outcomes, using Matta/Tornetta and Majeed criteria respectively, of the combination of trans-symphyseal cross-screws configuration and superior symphyseal plate in Tile-type B1 pelvic injuries. RESULTS Thirty patients, 18 with anteroposterior compression type II and 12 with type III, with a mean follow-up of 20 months ±5 were included. Radiologically, 26 (86.6%) cases showed an excellent, one (3.3%) good and three (10%) fair outcome. Clinically, excellent outcome in 26 (86.6%) cases, good in two (6.6%) cases, and fair in two (6.6%). Intra-operative drill bit breakage occurred in three (10%) cases and was the only reported technical complication. Significant re-displacement was reported in three (10%) cases. CONCLUSION The open trans-symphyseal cross-screws for fixation of the superior symphyseal plate is a simple, efficient, and safe technique with the biomechanical advantages of an extra-fixation point to the inferior symphysis together with a long and a strong bony anchorage.
Collapse
Affiliation(s)
- Fady Kamal Beder
- Pelvic Trauma and Arthroplasty Unit, Department of Orthopaedics and Traumatology, Kasr-Alainy Hospital, Cairo University, Cairo, Egypt
| | - Mohamed Salama Hamdy
- Pelvic Trauma and Arthroplasty Unit, Department of Orthopaedics and Traumatology, Kasr-Alainy Hospital, Cairo University, Cairo, Egypt
| | - Ihab Ibraheem El-Desouky
- Pelvic Trauma and Arthroplasty Unit, Department of Orthopaedics and Traumatology, Kasr-Alainy Hospital, Cairo University, Cairo, Egypt
| | - Khaled Fawzy Abdelkader
- Pelvic Trauma and Arthroplasty Unit, Department of Orthopaedics and Traumatology, Kasr-Alainy Hospital, Cairo University, Cairo, Egypt
| | - Ahmed Hazem Abdelazeem
- Pelvic Trauma and Arthroplasty Unit, Department of Orthopaedics and Traumatology, Kasr-Alainy Hospital, Cairo University, Cairo, Egypt.
| |
Collapse
|