1
|
Kee CL, Ge X, Low MY, Gilard V, Malet-Martino M. Analytical methods for the detection and characterization of unapproved phosphodiesterase type 5 inhibitors (PDE-5i) used in adulteration of dietary supplements- a review. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2023; 40:1495-1530. [PMID: 38011602 DOI: 10.1080/19440049.2023.2279567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 10/31/2023] [Indexed: 11/29/2023]
Abstract
This article is an up-to-date review of 112 unapproved phosphodiesterase type 5 inhibitors (PDE-5i) found as adulterants in sexual enhancement dietary supplements and other products from 2003 to July 2023. Seventy-five of these unapproved PDE-5i are analogues of sildenafil (67%), followed by 26 analogues of tadalafil (23%), 9 analogues of vardenafil (8%) and 2 other type of compounds (2%). The products have been formulated in various packaging, primarily in capsule, tablet, and powder forms. Common screening techniques allowing detection of such analogues include high performance or ultra-high performance liquid chromatography in tandem with ultra-violet detector (HPLC-UV or UPLC-UV) (50%) and thin-layer chromatography in tandem with ultra-violet detection (TLC-UV) (7%). Screening by mass spectrometry (MS) is relatively less common with the use of single-, triple-quadrupole or time-of-flight (TOF) mass spectrometers (9%). Meanwhile, the combined detection by UV-MS has been recorded at 10% usage. Screening by proton nuclear magnetic resonance spectroscopy (NMR) (11%) has also been applied. For compound characterization, i.e. structural elucidation, NMR spectroscopy has been preferred (100 out of 112 compounds), followed by high-resolution mass spectrometry (HRMS) (74 out of 112 compounds) and Fourier-transform infrared spectroscopy (FTIR) (44 out of 112 compounds). Over the past two decades, analytical technology has been evolving with enhanced sensitivity and resolution. Despite this, structural elucidation of the new emerging analogues in adulterated dietary supplements remains a challenge, especially when the analogues involve complex structural modification. Therefore, the above-mentioned techniques may not be adequate to characterize the analogues. Additional work involving chiroptical methods, two-dimensional (2D) NMR experiments and X-ray crystallography are likely to be required in the future.
Collapse
Affiliation(s)
- Chee-Leong Kee
- Pharmaceutical Laboratory, Applied Sciences Group, Health Sciences Authority, Singapore
| | - Xiaowei Ge
- Pharmaceutical Laboratory, Applied Sciences Group, Health Sciences Authority, Singapore
| | - Min-Yong Low
- Pharmaceutical Laboratory, Applied Sciences Group, Health Sciences Authority, Singapore
| | - Véronique Gilard
- Laboratoire IMRCP (UMR CNRS 5623), Université Paul Sabatier, Université de Toulouse, Toulouse cedex, France
| | - Myriam Malet-Martino
- Laboratoire SPCMIB (UMR CNRS 5068), Université Paul Sabatier, Université de Toulouse, Toulouse cedex, France
| |
Collapse
|
2
|
Wang XB, Zheng J, Li JJ, Yu HY, Li QY, Xu LH, Liu MJ, Xian RQ, Sun YE, Liu BJ. Simultaneous analysis of 23 illegal adulterated aphrodisiac chemical ingredients in health foods and Chinese traditional patent medicines by ultrahigh performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. J Food Drug Anal 2018; 26:1138-1153. [PMID: 29976406 PMCID: PMC9303026 DOI: 10.1016/j.jfda.2018.02.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 01/31/2018] [Accepted: 02/12/2018] [Indexed: 12/31/2022] Open
Abstract
This paper presents an application of ultra high-performance liquid-chromatography-quadrupole-TOF high resolution mass spectrometry (UHPLC-Q-TOF HRMS) for simultaneous analysis of 23 illegal adulterated aphrodisiac type chemical ingredients in health foods and Chinese Traditional Patent Medicines (CTPMs). The mass spectrometer was operated in Information Dependent Acquisition (IDA) mode, which provides crucial information for the elemental composition analysis, structure elucidation and quantitative analysis simultaneously. Quantitative analysis was performed using the peak areas of the precursor ions in the XICs. The method validation included assessment of selectivity, sensitivity, calibration curve, accuracy, precision, recovery, matrix effect and stability. The results show good linear relationship with the concentrations of the analytes over wide concentration ranges (e.g., 0.05–10 μg/g for sildenafil) as all the fitting coefficients of determination r2 are >0.9984. The detection limits (LODs) were in the range of 0.002–0.1 μg/g. The recoveries were able to reach 82.5–103.6%, while the matrix effects ranged from 87.7 to 109.3%. The intra- and inter-day accuracies were in the range of 82.3–113.8%, while the intra- and inter-day precision ranged from 0.4 to 13.6%. Among 40 batches of health foods and 32 batches of CTPMs (including 28 capsules, 32 tablets, 10 liquid and 2 pills) samples, 28 batches of heath foods were positive. The detected chemical ingredients involved sildenafil, tadalafil, aildenafil and sulfoaildenafil. This method can be used for the screening, identification and quantification of illegal adulterated aphrodisiac chemical ingredients in health foods and CTPMs. Moreover, the LC-Q-TOF MS is very useful to structural elucidation of unknown compound.
Collapse
|
3
|
Kee CL, Ge X, Gilard V, Malet-Martino M, Low MY. A review of synthetic phosphodiesterase type 5 inhibitors (PDE-5i) found as adulterants in dietary supplements. J Pharm Biomed Anal 2018; 147:250-277. [DOI: 10.1016/j.jpba.2017.07.031] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 07/17/2017] [Accepted: 07/26/2017] [Indexed: 10/19/2022]
|
4
|
Skalicka-Woźniak K, Georgiev MI, Orhan IE. Adulteration of herbal sexual enhancers and slimmers: The wish for better sexual well-being and perfect body can be risky. Food Chem Toxicol 2017; 108:355-364. [DOI: 10.1016/j.fct.2016.06.018] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2016] [Revised: 06/16/2016] [Accepted: 06/17/2016] [Indexed: 11/25/2022]
|
5
|
Ge X, Kee CL, Zeng Y, Low MY. Identification of Sildenafil Designer Analogues Found in Dietary Supplements. APPLICATIONS OF TIME-OF-FLIGHT AND ORBITRAP MASS SPECTROMETRY IN ENVIRONMENTAL, FOOD, DOPING, AND FORENSIC ANALYSIS 2016. [DOI: 10.1016/bs.coac.2016.01.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
6
|
Guo B, Wang M, Liu Y, Zhou J, Dai H, Huang Z, Shen L, Zhang Q, Chen B. Wide-Scope Screening of Illegal Adulterants in Dietary and Herbal Supplements via Rapid Polarity-Switching and Multistage Accurate Mass Confirmation Using an LC-IT/TOF Hybrid Instrument. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2015; 63:6954-6967. [PMID: 26189662 DOI: 10.1021/acs.jafc.5b02222] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A new analytical strategy was developed that integrates a generic sample preparation into a liquid chromatography-multistage ion trap/time-of-flight mass spectrometry (LC-IT(MS(n))/TOF), allowing for large-scale screening and qualitative confirmation of wide-scope illegal adulterants in different food matrices. Samples were pretreated by a fast single-tube multifunction extraction for accurate multistage mass measurement on the hybrid LC-IT/TOF system. A qualitative validation performed for over 500 analyte-matrix pairs showed the method can reduce most of the matrix effects and achieve a lower limit of confirmation at 0.1 mg/kg for 73% of the target compounds. A unique combination of dual-polarity detection, retention time, isotopic profile, and accurate MS(n) spectra enables more comprehensive and precise confirmation, based on the multiparameter matching by automated library searching against the user-created database. Finally, the applicability of this LC-IT(MS(n))/TOF-based screening procedure for discriminating coeluting isobars, identifying nontarget adulterants, and even tentatively elucidating unexpected species in real samples is demonstrated.
Collapse
Affiliation(s)
| | - Meiling Wang
- §Hunan Academy of Inspection and Quarantine and Food Safety Key Laboratory of Hunan Province, Hunan Entry-Exit Inspection and Quarantine Bureau of China, Changsha 410004, China
| | | | | | - Hua Dai
- §Hunan Academy of Inspection and Quarantine and Food Safety Key Laboratory of Hunan Province, Hunan Entry-Exit Inspection and Quarantine Bureau of China, Changsha 410004, China
| | - Zhiqiang Huang
- §Hunan Academy of Inspection and Quarantine and Food Safety Key Laboratory of Hunan Province, Hunan Entry-Exit Inspection and Quarantine Bureau of China, Changsha 410004, China
| | - Lingling Shen
- #Guangzhou Branch, Shimadzu (China) Co., Limited,7FL,T. P. Plaza, 9/109 Liuhua Road, Guangzhou 510010, China
| | - Qingsheng Zhang
- ΔNational Institutes for Food and Drug Control, Beijing 100050, China
| | | |
Collapse
|
7
|
Kee CL, Ge X, Low MY. Application of Orbitrap-mass spectrometry to differentiate isomeric sildenafil- and thiosildenafil-like analogues used for the adulteration of dietary supplements. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2015; 32:1737-48. [PMID: 26179419 DOI: 10.1080/19440049.2015.1062923] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Two groups of isomeric phosphodiestrase-type 5 inhibitors (PDE-5), consisting of four sildenafil- and three thiosildenafil-like analogues, have been successfully differentiated using high-resolution MS/MS. The optimised MS/MS data obtained from each compound were used to build a database with the aid of mass processing software. Isomeric compounds with very close chromatographic separation like dimethylsildenafil and homosildenafil could be distinguished by their unique fingerprint fragment ions in the MS/MS database. All fragment ions were within the mass tolerance of 5 ppm. One case study using an adulterated dietary supplement is included to provide more insights into this application.
Collapse
Affiliation(s)
- Chee-Leong Kee
- a Pharmaceutical Laboratory, Applied Sciences Group , Health Sciences Authority , Singapore , Singapore
| | - Xiaowei Ge
- a Pharmaceutical Laboratory, Applied Sciences Group , Health Sciences Authority , Singapore , Singapore
| | - Min-Yong Low
- a Pharmaceutical Laboratory, Applied Sciences Group , Health Sciences Authority , Singapore , Singapore
| |
Collapse
|
8
|
|
9
|
Gilard V, Balayssac S, Tinaugus A, Martins N, Martino R, Malet-Martino M. Detection, identification and quantification by 1H NMR of adulterants in 150 herbal dietary supplements marketed for improving sexual performance. J Pharm Biomed Anal 2014; 102:476-93. [PMID: 25459948 DOI: 10.1016/j.jpba.2014.10.011] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2014] [Revised: 10/08/2014] [Accepted: 10/10/2014] [Indexed: 12/31/2022]
Abstract
One hundred and fifty dietary supplements (DS) marketed to increase sexual performance were analyzed. All these formulations were claimed to contain only natural compounds, plant extracts and/or vitamins. (1)H NMR spectroscopy was used for detecting the presence of adulterants and for their identification and quantification. Mass spectrometry was used as a complementary method for confirming the chemical structures. 61% of DS were adulterated with phosphodiesterase-5 inhibitors (PDE-5i) (27% with the PDE-5i medicines sildenafil, tadalafil and vardenafil, and 34% with their structurally modified analogues). Among them, 64% contained only one PDE-5i and 36% mixtures of two, three and even four. The amounts of PDE-5i medicines were higher than the maximum recommended dose in 25% of DS tainted with these drugs. Additional 5.5% DS included other drugs for the treatment of sexual dysfunction (yohimbine, flibanserin, phentolamine, dehydroepiandrosterone or testosterone). Some DS (2.5%) contained products (osthole, icariin) extracted from plants known to improve sexual performance. Only 31% of the samples could be considered as true herbal/natural products. A follow-up over time of several DS revealed that manufacturers make changes in the chemical composition of the formulations. Lack of quality or consistent manufacture (contamination possibly due to inadequate cleaning of the manufacturing chain, presence of impurities or degradation products, various compositions of a given DS with the same batch number, inadequate labelling) indicated poor manufacturing practices. In conclusion, this paper demonstrates the power of (1)H NMR spectroscopy as a first-line method for the detection of adulterated herbal/natural DS and the need for more effective quality control of purported herbal DS.
Collapse
Affiliation(s)
- Véronique Gilard
- Groupe de RMN Biomédicale, Laboratoire SPCMIB (UMR CNRS 5068), Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse cedex 9, France
| | - Stéphane Balayssac
- Groupe de RMN Biomédicale, Laboratoire SPCMIB (UMR CNRS 5068), Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse cedex 9, France
| | - Aurélie Tinaugus
- Groupe de RMN Biomédicale, Laboratoire SPCMIB (UMR CNRS 5068), Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse cedex 9, France
| | - Nathalie Martins
- Service commun de spectrométrie de masse, Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse cedex 9, France
| | - Robert Martino
- Groupe de RMN Biomédicale, Laboratoire SPCMIB (UMR CNRS 5068), Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse cedex 9, France
| | - Myriam Malet-Martino
- Groupe de RMN Biomédicale, Laboratoire SPCMIB (UMR CNRS 5068), Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse cedex 9, France.
| |
Collapse
|