1
|
Sakineh Esfandiari Baghbamidi. Surface Modification of Glassy Carbon Electrode Using Hematoxylin and MWCNTs/Fe3O4/TiO2 Nanocomposite; a Sensitive Electrochemical Technique for Detection of Methyldopa in the Presence of Folic Acid. RUSS J ELECTROCHEM+ 2022. [DOI: 10.1134/s1023193522060040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
2
|
Kaya SI, Cetinkaya A, Ozkan SA. Carbon Nanomaterial-Based Drug Sensing Platforms Using State-of-the-
Art Electroanalytical Techniques. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999200802024629] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Currently, nanotechnology and nanomaterials are considered as the most popular and outstanding
research subjects in scientific fields ranging from environmental studies to drug analysis. Carbon nanomaterials such as
carbon nanotubes, graphene, carbon nanofibers etc. and non-carbon nanomaterials such as quantum dots, metal
nanoparticles, nanorods etc. are widely used in electrochemical drug analysis for sensor development. Main aim of drug
analysis with sensors is developing fast, easy to use and sensitive methods. Electroanalytical techniques such as
voltammetry, potentiometry, amperometry etc. which measure electrical parameters such as current or potential in an
electrochemical cell are considered economical, highly sensitive and versatile techniques.
Methods:
Most recent researches and studies about electrochemical analysis of drugs with carbon-based nanomaterials were
analyzed. Books and review articles about this topic were reviewed.
Results:
The most significant carbon-based nanomaterials and electroanalytical techniques were explained in detail. In
addition to this; recent applications of electrochemical techniques with carbon nanomaterials in drug analysis was expressed
comprehensively. Recent researches about electrochemical applications of carbon-based nanomaterials in drug sensing were
given in a table.
Conclusion:
Nanotechnology provides opportunities to create functional materials, devices and systems using
nanomaterials with advantageous features such as high surface area, improved electrode kinetics and higher catalytic
activity. Electrochemistry is widely used in drug analysis for pharmaceutical and medical purposes. Carbon nanomaterials
based electrochemical sensors are one of the most preferred methods for drug analysis with high sensitivity, low cost and
rapid detection.
Collapse
Affiliation(s)
- S. Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| | - Sibel A. Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560, Ankara,Turkey
| |
Collapse
|
3
|
Jlalia I, Zouaoui F, Chabbah T, Chatti S, Saint-Martin P, Casabianca H, Minot S, Bessueille F, Marestin C, Mercier R, Errachid A, Abderrazak H, Hammami M, Jaffrezic-Renault N. Adsorption Characteristics of WFD Heavy Metal Ions on New Biosourced Polyimide Films Determined by Electrochemical Impedance Spectroscopy. J Inorg Organomet Polym Mater 2021. [DOI: 10.1007/s10904-020-01842-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
4
|
Rajasekhar Chokkareddy, Gan G Redhi. A Facile Electrochemical Sensor Based on Ionic Liquid Functionalized Multiwalled Carbon Nanotubes for Isoniazid Detection. JOURNAL OF ANALYTICAL CHEMISTRY 2020. [DOI: 10.1134/s1061934820120059] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
5
|
Amiri M, Nekoueian K, Saberi RS. Graphene-family materials in electrochemical aptasensors. Anal Bioanal Chem 2020; 413:673-699. [PMID: 32939567 DOI: 10.1007/s00216-020-02915-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 08/02/2020] [Accepted: 08/25/2020] [Indexed: 02/07/2023]
Abstract
The study of graphene-based carbon nanocomposites has remarkably increased in recent years. Functionalized graphene-based nanostructures, including graphene oxide and reduced graphene oxide, have great potential as new innovative electrode materials in the fabrication of novel electrochemical sensors. Electrochemical sensors based on aptamers attracted great attention because of their high sensitivity and selectivity, and simple instrumentation, as well as low production cost. Aptamers as a potent alternative to antibodies are functional nucleic acids with a high tendency to specific analytes. Electrochemical aptasensors show specific recognition ability for a wide range of analytes. Although aptamers are selected in vitro in contrast to antibodies, they are interesting due to advantages like high stability, easy chemical modifications, and the potential to be employed in nanostructured device fabrication or electrochemical sensing devices. Recently, new nanomaterials have shown a significant impact on the production of electrochemical sensors with high efficiency and performance. This review aims to give an outline of electrochemical aptasensors based on the graphene family materials and discuss the detection mechanism in this type of aptasensors. The present review summarizes some of the recent achievements in graphene-based aptasensors and includes their recent electroanalytical applications. Graphical Abstract Graphical Abstract.
Collapse
Affiliation(s)
- Mandana Amiri
- Department of Chemistry, University of Mohaghegh Ardabili, Daneshgah Street, Ardabil, 56199-11367, Iran.
| | - Khadijeh Nekoueian
- Department of Chemistry, University of Mohaghegh Ardabili, Daneshgah Street, Ardabil, 56199-11367, Iran
| | - Reyhaneh Sadat Saberi
- East Sage Investigative Corporation, Isfahan Science and Technology Town, Isfahan, 8415683111, Iran
| |
Collapse
|
6
|
Vogiazi V, de la Cruz A, Mishra S, Shanov V, Heineman WR, Dionysiou DD. A Comprehensive Review: Development of Electrochemical Biosensors for Detection of Cyanotoxins in Freshwater. ACS Sens 2019; 4:1151-1173. [PMID: 31056912 PMCID: PMC6625642 DOI: 10.1021/acssensors.9b00376] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Cyanobacteria harmful algal blooms are increasing in frequency and cyanotoxins have become an environmental and public concern in the U.S. and worldwide. In this Review, the majority of reported studies and developments of electrochemical affinity biosensors for cyanotoxins are critically reviewed and discussed. Essential background information about cyanobacterial toxins and electrochemical biosensors is combined with the rapidly moving development of electrochemical biosensors for these toxins. Current issues and future challenges for the development of useful electrochemical biosensors for cyanotoxin detection that meet the demands for applications in field freshwater samples are discussed. The major aspects of the entire review article in a prescribed sequence include (i) the state-of-the-art knowledge of the toxicity of cyanotoxins, (ii) important harmful algal bloom events, (iii) advisories, guidelines, and regulations, (iv) conventional analytical methods for determination of cyanotoxins, (v) electrochemical transduction, (vi) recognition receptors, (vii) reported electrochemical biosensors for cyanotoxins, (viii) summary of analytical performance, and (ix) recent advances and future trends. Discussion includes electrochemical techniques and devices, biomolecules with high affinity, numerous array designs, various detection approaches, and research strategies in tailoring the properties of the transducer-biomolecule interface. Scientific and engineering aspects are presented in depth. This review aims to serve as a valuable source to scientists and engineers entering the interdisciplinary field of electrochemical biosensors for detection of cyanotoxins in freshwaters.
Collapse
Affiliation(s)
- Vasileia Vogiazi
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| | - Armah de la Cruz
- Office of Research and Development , US Environmental Protection Agency , Cincinnati , Ohio 45220 , United States
| | - Siddharth Mishra
- Mechanical and Materials Engineering , University of Cincinnati , Cincinnati 45221 , Ohio United States
| | - Vesselin Shanov
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
- Mechanical and Materials Engineering , University of Cincinnati , Cincinnati 45221 , Ohio United States
| | - William R Heineman
- Department of Chemistry , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| | - Dionysios D Dionysiou
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| |
Collapse
|
7
|
Díaz E, Stożek S, Patiño Y, Ordóñez S. Electrochemical degradation of naproxen from water by anodic oxidation with multiwall carbon nanotubes glassy carbon electrode. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2019; 79:480-488. [PMID: 30924802 DOI: 10.2166/wst.2019.070] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Naproxen (NPX) degradation was investigated by anodic oxidation both at constant potential and by cyclic voltammetry, using this last technique for optimizing reaction conditions and catalyst properties. Three multiwall carbon nanotubes (MWCNTs)-promoted electrodes were used (MWCNT, MWCNT-COOH and MWCNT-NH2) and a two steps oxidation process was observed in all the cases. At the optimized conditions (volume of MWCNT = 15 μL), the influence of the scan rate indicates the diffusion-adsorption control of the process. Likewise, the kinetic study of NPX degradation at fix potential, considering two different stirring speeds (250 and 500 rpm), indicates that degradation rate increases with the stirring speed. After 20 h, NPX is degraded even an 82.5%, whereas the mineralization reaches almost 70%, as it was obtained from total organic carbon analysis. The pH effect was also analysed, in the range 5-11, observing a positive effect at low pH. Concerning the surface chemistry of the electrode, MWCNT-NH2, with the highest isoelectric point (4.70), is the most promising material due to the improved interactions with the reactant. From these observations, a pathway is proposed, which includes two steps of electrochemical oxidation followed by subsequent oxidation steps, until mineralization of the NPX, attributed mainly to active chlorine species and ·OH.
Collapse
Affiliation(s)
- Eva Díaz
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain E-mail:
| | - Sonia Stożek
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain E-mail:
| | - Yolanda Patiño
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain E-mail:
| | - Salvador Ordóñez
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain E-mail:
| |
Collapse
|
8
|
Alam AU, Qin Y, Catalano M, Wang L, Kim MJ, Howlader MMR, Hu NX, Deen MJ. Tailoring MWCNTs and β-Cyclodextrin for Sensitive Detection of Acetaminophen and Estrogen. ACS APPLIED MATERIALS & INTERFACES 2018; 10:21411-21427. [PMID: 29856206 DOI: 10.1021/acsami.8b04639] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Monitoring of trace amount of acetaminophen and estrogen in drinking water is of great importance because of their potential links to gastrointestinal diseases and breast and prostate cancers. The sensitive and accurate detection of acetaminophen and estrogen requires the development of advanced sensing materials that possess appropriate number of analyte-capturing sites and suitable signal conduction path. This can be achieved by implementing appropriate chemical attachment of multiwalled carbon nanotubes (MWCNTs) and β-cyclodextrin (βCD). Here, we report a systematic investigation of four types of modified MWCNT-βCD: (1) physical mixing, (2) "click reaction", (3) thionyl chloride esterification, and (4) Steglich esterification. The Steglich esterification is a one-step approach with shorter reaction time, lower reaction temperature, and eliminates handling of air/moisture-sensitive reagents. MWCNT-βCD prepared by Steglich esterification possessed moderate βCD loading (5-10 wt %), large effective surface area, and fast electron transfer. The host-guest interaction of βCD and redox properties of MWCNT enabled sensitive detection of acetaminophen and 17β-estradiol (E2 is a primary female sex hormone) in the range of 0.005-20 and 0.01-15 μM, with low detection limits of 3.3 and 2.5 nM, respectively. We demonstrated accurate detection results of pharmaceutical compositions in water and urine samples. These results indicate that Steglich esterification method may be applied in fabricating pharmaceutical contaminants sensors for health and environmental applications.
Collapse
Affiliation(s)
- Arif Ul Alam
- Department of Electrical and Computer Engineering , McMaster University , 1280 Main Street West , Hamilton , Ontario L8S 4K1 , Canada
- Advanced Materials Laboratory , Xerox Research Centre of Canada , 2660 Speakman Drive , Mississauga , Ontario L5K 2L1 , Canada
| | - Yiheng Qin
- Department of Electrical and Computer Engineering , McMaster University , 1280 Main Street West , Hamilton , Ontario L8S 4K1 , Canada
- Advanced Materials Laboratory , Xerox Research Centre of Canada , 2660 Speakman Drive , Mississauga , Ontario L5K 2L1 , Canada
| | - Massimo Catalano
- Department of Materials Science and Engineering , The University of Texas at Dallas , 800 West Campbell Road , Richardson , Texas 75080 , United States
- CNR-IMM , Via Monteroni, ed.A3 , Lecce 73100 , Italy
| | - Luhua Wang
- Department of Materials Science and Engineering , The University of Texas at Dallas , 800 West Campbell Road , Richardson , Texas 75080 , United States
| | - Moon J Kim
- Department of Materials Science and Engineering , The University of Texas at Dallas , 800 West Campbell Road , Richardson , Texas 75080 , United States
| | - Matiar M R Howlader
- Department of Electrical and Computer Engineering , McMaster University , 1280 Main Street West , Hamilton , Ontario L8S 4K1 , Canada
| | - Nan-Xing Hu
- Advanced Materials Laboratory , Xerox Research Centre of Canada , 2660 Speakman Drive , Mississauga , Ontario L5K 2L1 , Canada
| | - M Jamal Deen
- Department of Electrical and Computer Engineering , McMaster University , 1280 Main Street West , Hamilton , Ontario L8S 4K1 , Canada
| |
Collapse
|
9
|
Patiño Y, Díaz E, Lobo-Castañón MJ, Ordóñez S. Carbon nanotube modified glassy carbon electrode for electrochemical oxidation of alkylphenol ethoxylate. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2018; 77:2436-2444. [PMID: 29893732 DOI: 10.2166/wst.2018.196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Electrochemical oxidation of an emerging pollutant, 2-(4-methylphenoxy)ethanol (MPET), from water has been studied by cyclic voltammetry (CV). Multiwall carbon nanotubes glassy carbon electrodes (MWCNT-GCE) were used as working electrode due to their extraordinary properties. The oxidation process is irreversible, since no reduction peaks were observed in the reverse scan. The electrocatalytic effect of MWCNT was confirmed as the oxidation peak intensity increases in comparison to bare-GCE. The effect of functional groups on MWCNT was also studied by MWCNT functionalized with NH2 (MWCNT-NH2) and COOH (MWCNT-COOH) groups. The oxidation peak current decreases in the following order: MWCNT > MWCNT-NH2 > MWCNT-COOH. Taking into account the normalized peak current, MWCNT-NH2 exhibits the best results due to its strong interaction with MPET. Under optimal conditions (pH = 5.0 and volume of MWCNT = 10 μL), degradation was studied for MWCNT-GCE and MWCNT-NH2-GCE. A complete MPET removal was observed using MWCNT-GCE after four CV cycles, for a volume/area (V/A) ratio equal to 19. In the case of MWCNT-NH2-GCE, the maximum MPET removal was close to 90% for V/A = 37, higher than that obtained for MWCNT-GCE at the same conditions (≈80%). In both cases, no organic by-products were detected.
Collapse
Affiliation(s)
- Yolanda Patiño
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, Oviedo 33006, Spain
| | - Eva Díaz
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, Oviedo 33006, Spain
| | - María Jesús Lobo-Castañón
- Department of Physical and Analytical Chemistry, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, Oviedo 33006, Spain
| | - Salvador Ordóñez
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, Oviedo 33006, Spain
| |
Collapse
|
10
|
McBeth C, Dughaishi RA, Paterson A, Sharp D. Ubiquinone modified printed carbon electrodes for cell culture pH monitoring. Biosens Bioelectron 2018; 113:46-51. [PMID: 29727751 DOI: 10.1016/j.bios.2018.04.052] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 04/06/2018] [Accepted: 04/24/2018] [Indexed: 11/30/2022]
Abstract
The measurement of pH is important throughout many biological systems, but there are limited available technologies to enable its periodical monitoring in the complex, small volume, media often used in cell culture experiments across a range of disciplines. Herein, pad printed electrodes are developed and characterised through modification with: a commercially available fullerene multiwall carbon nanotube composite applied in Nafion, casting of hydrophobic ubiquinone as a pH probe to provide the electrochemical signal, and coated in Polyethylene glycol to reduce fouling and potentially enhance biocompatibility, which together are proven to enable the determination of pH in cell culture media containing serum. The ubiquinone oxidation peak position (Epa) provided an indirect marker of pH across the applicable range of pH 6-9 (R2 = 0.9985, n = 15) in complete DMEM. The electrochemical behaviour of these sensors was also proven to be robust; retaining their ability to measure pH in cell culture media supplemented with serum up to 20% (v/v) [encompassing the range commonly employed in cell culture], cycled > 100 times in 10% serum containing media and maintain > 60% functionality after 5 day incubation in a 10% serum containing medium. Overall, this proof of concept research highlights the potential applicability of this, or similar, electrochemical approaches to enable to detection or monitoring of pH in complex cell culture media.
Collapse
Affiliation(s)
- Craig McBeth
- Centre for Biomedical Science Research, School of Clinical and Applied Sciences, Leeds Beckett University, Leeds LS1 3HE, United Kingdom
| | - Rajaa Al Dughaishi
- Centre for Biomedical Science Research, School of Clinical and Applied Sciences, Leeds Beckett University, Leeds LS1 3HE, United Kingdom
| | - Andrew Paterson
- Centre for Biomedical Science Research, School of Clinical and Applied Sciences, Leeds Beckett University, Leeds LS1 3HE, United Kingdom
| | - Duncan Sharp
- Centre for Biomedical Science Research, School of Clinical and Applied Sciences, Leeds Beckett University, Leeds LS1 3HE, United Kingdom.
| |
Collapse
|
11
|
Patiño Y, Pilehvar S, Díaz E, Ordóñez S, De Wael K. Electrochemical reduction of nalidixic acid at glassy carbon electrode modified with multi-walled carbon nanotubes. JOURNAL OF HAZARDOUS MATERIALS 2017; 323:621-631. [PMID: 27776850 DOI: 10.1016/j.jhazmat.2016.10.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Revised: 09/25/2016] [Accepted: 10/12/2016] [Indexed: 06/06/2023]
Abstract
The aqueous phase electrochemical degradation of nalidixic acid (NAL) is studied in this work, using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) as instrumental techniques. The promotional effect of multi-walled carbon nanotubes (MWCNT) on the performance of glassy carbon electrodes is demonstrated, being observed that these materials catalyze the NAL reduction. The effect of surface functional groups on MWCNT -MWCNT-COOH and MWCNT-NH2-was also studied. The modification of glassy carbon electrode (GCE) with MWCNT leads to an improved performance for NAL reduction following the order of MWCNT>MWCNT-NH2>MWCNT-COOH. The best behavior at MWCNT-GCE is mainly due to both the increased electrode active area and the enhanced MWCNT adsorption properties. The NAL degradation was carried out under optimal conditions (pH=5.0, deposition time=20s and volume of MWCNT=10μL) using MWCNT-GCE obtaining an irreversible reduction of NAL to less toxic products. Paramaters as the number of DPV cycles and the volume/area (V/A) ratio were optimized for maximize pollutant degradation. It was observed that after 15 DPV scans and V/A=8, a complete reduction was obtained, obtaining two sub-products identified by liquid chromatography-mass spectrometry (LC-MS).
Collapse
Affiliation(s)
- Yolanda Patiño
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain
| | - Sanaz Pilehvar
- AXES Research Group, Department of Chemistry, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Eva Díaz
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain
| | - Salvador Ordóñez
- Department of Chemical and Environmental Engineering, University of Oviedo, Faculty of Chemistry, Julián Clavería s/n, 33006 Oviedo, Spain.
| | - Karolien De Wael
- AXES Research Group, Department of Chemistry, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| |
Collapse
|
12
|
Ionic Liquid Crystals Modifier for Selective Determination of Terazosin Antihypertensive Drug in Presence of Common Interference Compounds. CRYSTALS 2017. [DOI: 10.3390/cryst7010027] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
13
|
ATTA NF, BINSABT MH, EL-ADS EH, GALAL A. Synthesis of neodymium-iron nanoperovskite for sensing applications of an antiallergic drug. Turk J Chem 2017. [DOI: 10.3906/kim-1610-73] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
|
14
|
Kumaravel A, Chandrasekaran M. Electrochemical Determination of Chlorpyrifos on a Nano-TiO₂Cellulose Acetate Composite Modified Glassy Carbon Electrode. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2015; 63:6150-6156. [PMID: 26075585 DOI: 10.1021/acs.jafc.5b02057] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A rapid and simple method of determination of chlorpyrifos is important in environmental monitoring and quality control. Electrochemical methods for the determination of pesticides are fast, sensitive, reproducible, and cost-effective. The key factor in electrochemical methods is the choice of suitable electrode materials. The electrode materials should have good stability, reproducibility, more sensitivity, and easy method of preparation. Mercury-based electrodes have been widely used for the determination of chlorpyrifos. From an environmental point of view mercury cannot be used. In this study a biocompatible nano-TiO2/cellulose acetate modified glassy carbon electrode was prepared by a simple method and used for the electrochemical sensing of chlorpyrifos in aqueous methanolic solution. Electroanalytical techniques such as cyclic voltammetry, differential pulse voltammetry, and amperometry were used in this work. This electrode showed very good stability, reproducibility, and sensitivity. A well-defined peak was obtained for the reduction of chlorpyrifos in cyclic voltammetry and differential pulse voltammetry. A smooth noise-free current response was obtained in amperometric analysis. The peak current obtained was proportional to the concentration of chlorpyrifos and was used to determine the unknown concentration of chlorpyrifos in the samples. Analytical parameters such as LOD, LOQ, and linear range were estimated. Analysis of real samples was also carried out. The results were validated through HPLC. This composite electrode can be used as an alternative to mercury electrodes reported in the literature.
Collapse
Affiliation(s)
- Ammasai Kumaravel
- §PSG Institute of Technology and Applied Research, Coimbatore 641062, Tamil Nadu, India
| | - Maruthai Chandrasekaran
- †CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi 630006, Tamil Nadu, India
| |
Collapse
|
15
|
Carbon Nanotube-Based Electrochemical Sensor for the Determination of Anthraquinone Hair Dyes in Wastewaters. CHEMOSENSORS 2015. [DOI: 10.3390/chemosensors3010022] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
|
17
|
Kutluay A, Aslanoglu M. An electrochemical sensor prepared by sonochemical one-pot synthesis of multi-walled carbon nanotube-supported cobalt nanoparticles for the simultaneous determination of paracetamol and dopamine. Anal Chim Acta 2014; 839:59-66. [DOI: 10.1016/j.aca.2014.05.018] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2013] [Revised: 04/28/2014] [Accepted: 05/09/2014] [Indexed: 11/16/2022]
|