1
|
Sorzano COS, Jiménez-Moreno A, Maluenda D, Martínez M, Ramírez-Aportela E, Krieger J, Melero R, Cuervo A, Conesa J, Filipovic J, Conesa P, del Caño L, Fonseca YC, Jiménez-de la Morena J, Losana P, Sánchez-García R, Strelak D, Fernández-Giménez E, de Isidro-Gómez FP, Herreros D, Vilas JL, Marabini R, Carazo JM. On bias, variance, overfitting, gold standard and consensus in single-particle analysis by cryo-electron microscopy. Acta Crystallogr D Struct Biol 2022; 78:410-423. [PMID: 35362465 PMCID: PMC8972802 DOI: 10.1107/s2059798322001978] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 02/18/2022] [Indexed: 12/05/2022] Open
Abstract
Single-particle analysis (SPA) by cryo-electron microscopy comprises the estimation of many parameters along its image-processing pipeline. Overfitting observed in SPA is normally due to misestimated parameters, and the only way to identify these is by comparing the estimates of multiple algorithms or, at least, multiple executions of the same algorithm. Cryo-electron microscopy (cryoEM) has become a well established technique to elucidate the 3D structures of biological macromolecules. Projection images from thousands of macromolecules that are assumed to be structurally identical are combined into a single 3D map representing the Coulomb potential of the macromolecule under study. This article discusses possible caveats along the image-processing path and how to avoid them to obtain a reliable 3D structure. Some of these problems are very well known in the community. These may be referred to as sample-related (such as specimen denaturation at interfaces or non-uniform projection geometry leading to underrepresented projection directions). The rest are related to the algorithms used. While some have been discussed in depth in the literature, such as the use of an incorrect initial volume, others have received much less attention. However, they are fundamental in any data-analysis approach. Chiefly among them, instabilities in estimating many of the key parameters that are required for a correct 3D reconstruction that occur all along the processing workflow are referred to, which may significantly affect the reliability of the whole process. In the field, the term overfitting has been coined to refer to some particular kinds of artifacts. It is argued that overfitting is a statistical bias in key parameter-estimation steps in the 3D reconstruction process, including intrinsic algorithmic bias. It is also shown that common tools (Fourier shell correlation) and strategies (gold standard) that are normally used to detect or prevent overfitting do not fully protect against it. Alternatively, it is proposed that detecting the bias that leads to overfitting is much easier when addressed at the level of parameter estimation, rather than detecting it once the particle images have been combined into a 3D map. Comparing the results from multiple algorithms (or at least, independent executions of the same algorithm) can detect parameter bias. These multiple executions could then be averaged to give a lower variance estimate of the underlying parameters.
Collapse
|
2
|
Sorzano COS, Semchonok D, Lin SC, Lo YC, Vilas JL, Jiménez-Moreno A, Gragera M, Vacca S, Maluenda D, Martínez M, Ramírez-Aportela E, Melero R, Cuervo A, Conesa JJ, Conesa P, Losana P, Caño LD, de la Morena JJ, Fonseca YC, Sánchez-García R, Strelak D, Fernández-Giménez E, de Isidro F, Herreros D, Kastritis PL, Marabini R, Bruce BD, Carazo JM. Algorithmic robustness to preferred orientations in single particle analysis by CryoEM. J Struct Biol 2021; 213:107695. [PMID: 33421545 DOI: 10.1016/j.jsb.2020.107695] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 12/18/2020] [Accepted: 12/24/2020] [Indexed: 01/30/2023]
Abstract
The presence of preferred orientations in single particle analysis (SPA) by cryo-Electron Microscopy (cryoEM) is currently one of the hurdles preventing many structural analyses from yielding high-resolution structures. Although the existence of preferred orientations is mostly related to the grid preparation, in this technical note, we show that some image processing algorithms used for angular assignment and three-dimensional (3D) reconstruction are more robust than others to these detrimental conditions. We exemplify this argument with three different data sets in which the presence of preferred orientations hindered achieving a 3D reconstruction without artifacts or, even worse, a 3D reconstruction could never be achieved.
Collapse
Affiliation(s)
- C O S Sorzano
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain.
| | - D Semchonok
- ZIK HALOMEM & Institute of Biochemistry and Biotechnology, Martin Luther University Halle-Wittenberg, Biozentrum, Halle (Saale), Germany
| | - S-C Lin
- Genomics Research Center, Academia Sinica, Taipei 11529, Taiwan
| | - Y-C Lo
- Dept. Biotechnology and Bioindustry Sciences, College of Bioscience and Biotechnology, National Cheng Kung University, Tainan 70101, Taiwan
| | - J L Vilas
- Dept. of Biomedical Engineering, Yale University, New Haven, United States
| | - A Jiménez-Moreno
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - M Gragera
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - S Vacca
- Dept. of Biochemistry, Univ. Zurich, Winterthurerstr. 190, CH-8057 Zurich, Switzerland
| | - D Maluenda
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - M Martínez
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - E Ramírez-Aportela
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - R Melero
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - A Cuervo
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - J J Conesa
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - P Conesa
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - P Losana
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - L Del Caño
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - J Jiménez de la Morena
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - Y C Fonseca
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - R Sánchez-García
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - D Strelak
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - E Fernández-Giménez
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - F de Isidro
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - D Herreros
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - P L Kastritis
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| | - R Marabini
- Escuela Politecnica Superior, Universidad Autónoma de Madrid, 28049 Cantoblanco, Madrid, Spain
| | - B D Bruce
- Dept. Biochemistry & Cellular and Molecular Biology, Univ. Tennessee Knoxville, Knoxville, TN 37996, United States
| | - J M Carazo
- Biocomputing Unit, Centro Nacional de Biotecnologia (CNB-CSIC), Darwin, 3, Campus Universidad Autonoma, 28049 Cantoblanco, Madrid, Spain
| |
Collapse
|
3
|
Ramírez-Aportela E, Mota J, Conesa P, Carazo JM, Sorzano COS. DeepRes: a new deep-learning- and aspect-based local resolution method for electron-microscopy maps. IUCRJ 2019; 6:1054-1063. [PMID: 31709061 PMCID: PMC6830216 DOI: 10.1107/s2052252519011692] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Accepted: 08/22/2019] [Indexed: 05/26/2023]
Abstract
In this article, a method is presented to estimate a new local quality measure for 3D cryoEM maps that adopts the form of a 'local resolution' type of information. The algorithm (DeepRes) is based on deep-learning 3D feature detection. DeepRes is fully automatic and parameter-free, and avoids the issues of most current methods, such as their insensitivity to enhancements owing to B-factor sharpening (unless the 3D mask is changed), among others, which is an issue that has been virtually neglected in the cryoEM field until now. In this way, DeepRes can be applied to any map, detecting subtle changes in local quality after applying enhancement processes such as isotropic filters or substantially more complex procedures, such as model-based local sharpening, non-model-based methods or denoising, that may be very difficult to follow using current methods. It performs as a human observer expects. The comparison with traditional local resolution indicators is also addressed.
Collapse
Affiliation(s)
- Erney Ramírez-Aportela
- Biocomputing Unit, National Center for Biotechnology (CSIC), Calle Darwin 3, Campus Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Javier Mota
- Biocomputing Unit, National Center for Biotechnology (CSIC), Calle Darwin 3, Campus Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Pablo Conesa
- Biocomputing Unit, National Center for Biotechnology (CSIC), Calle Darwin 3, Campus Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Jose Maria Carazo
- Biocomputing Unit, National Center for Biotechnology (CSIC), Calle Darwin 3, Campus Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Carlos Oscar S. Sorzano
- Biocomputing Unit, National Center for Biotechnology (CSIC), Calle Darwin 3, Campus Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
- Universidad CEU San Pablo, Campus Urbanizacion Montepríncipe, Boadilla del Monte, 28668 Madrid, Spain
| |
Collapse
|
4
|
Heymann JB. Single-particle reconstruction statistics: a diagnostic tool in solving biomolecular structures by cryo-EM. Acta Crystallogr F Struct Biol Commun 2019; 75:33-44. [PMID: 30605123 PMCID: PMC6317460 DOI: 10.1107/s2053230x18017636] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Accepted: 12/13/2018] [Indexed: 11/10/2022] Open
Abstract
In single-particle analysis (SPA), the aim is to obtain a 3D reconstruction of a biological molecule from 2D electron micrographs to the highest level of detail or resolution as possible. Current practice is to collect large volumes of data, hoping to reach high-resolution maps through sheer numbers. However, adding more particles from a specific data set eventually leads to diminishing improvements in resolution. Understanding what these resolution limits are and how to deal with them are important in optimization and automation of SPA. This study revisits the theory of 3D reconstruction and demonstrates how the associated statistics can provide a diagnostic tool to improve SPA. Small numbers of images already give sufficient information on micrograph quality and the amount of data required to reach high resolution. Such feedback allows the microscopist to improve sample-preparation and imaging parameters before committing to extensive data collection. Once a larger data set is available, a B factor can be determined describing the suppression of the signal owing to one or more causes, such as specimen movement, radiation damage, alignment inaccuracy and structural variation. Insight into the causes of signal suppression can then guide the user to consider appropriate actions to obtain better reconstructions.
Collapse
Affiliation(s)
- J Bernard Heymann
- Laboratory for Structural Biology Research, NIAMS, National Institutes of Health, Bethesda, MD 20892, USA
| |
Collapse
|
5
|
A Local Agreement Filtering Algorithm for Transmission EM Reconstructions. J Struct Biol 2018; 205:30-40. [PMID: 30502495 PMCID: PMC6351148 DOI: 10.1016/j.jsb.2018.11.011] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Revised: 11/14/2018] [Accepted: 11/25/2018] [Indexed: 12/04/2022]
Abstract
We propose an algorithm, LAFTER, that recovers features with more signal than noise from half maps. LAFTER is shown to recover features over a wide range of FSCs and local signal-to-noise ratios. We suggest effective local noise suppression be evaluated by comparing the filter-sum xFSC to Cref.
We present LAFTER, an algorithm for de-noising single particle reconstructions from cryo-EM. Single particle analysis entails the reconstruction of high-resolution volumes from tens of thousands of particle images with low individual signal-to-noise. Imperfections in this process result in substantial variations in the local signal-to-noise ratio within the resulting reconstruction, complicating the interpretation of molecular structure. An effective local de-noising filter could therefore improve interpretability and maximise the amount of useful information obtained from cryo-EM maps. LAFTER is a local de-noising algorithm based on a pair of serial real-space filters. It compares independent half-set reconstructions to identify and retain shared features that have power greater than the noise. It is capable of recovering features across a wide range of signal-to-noise ratios, and we demonstrate recovery of the strongest features at Fourier shell correlation (FSC) values as low as 0.144 over a 2563-voxel cube. A fast and computationally efficient implementation of LAFTER is freely available. We also propose a new way to evaluate the effectiveness of real-space filters for noise suppression, based on the correspondence between two FSC curves: 1) the FSC between the filtered and unfiltered volumes, and 2) Cref, the FSC between the unfiltered volume and a hypothetical noiseless volume, which can readily be estimated from the FSC between two half-set reconstructions.
Collapse
|
6
|
Yang YJ, Wang S, Zhang B, Shen HB. Resolution Measurement from a Single Reconstructed Cryo-EM Density Map with Multiscale Spectral Analysis. J Chem Inf Model 2018; 58:1303-1311. [DOI: 10.1021/acs.jcim.8b00149] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Yu-Jiao Yang
- Institute of Image Processing and Pattern Recognition and MOE Key Laboratory of System Control and Information Processing, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Shuai Wang
- Institute of Image Processing and Pattern Recognition and MOE Key Laboratory of System Control and Information Processing, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Biao Zhang
- Institute of Image Processing and Pattern Recognition and MOE Key Laboratory of System Control and Information Processing, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Hong-Bin Shen
- Institute of Image Processing and Pattern Recognition and MOE Key Laboratory of System Control and Information Processing, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
7
|
Abstract
Structural studies of biocomplexes using single-particle cryo-electron microscopy (cryo-EM) is now a well-established technique in structural biology and has become competitive with X-ray crystallography. The latest advances in EM enable us to determine structures of protein complexes at 3-5 Å resolution for an extremely broad range of sizes from ~200 kDa up to hundreds of megadaltons (Bartesaghi et al., Science 348(6239):1147-1151, 2051; Bai et al., Nature 525(7568):212-217, 2015; Vinothkumar et al., Nature 515(7525):80-84, 2014; Grigorieff and Harrison, Curr Opin Struct Biol 21(2):265-273, 2011). The majority of biocomplexes comprise a number of different components and are not amenable to crystallisation. Secretion systems are typical examples of such multi-protein complexes, and structural studies of them are extremely challenging. The only feasible approach to revealing their spatial organisation and functional modification is cryo-EM. The development of systems for digital registration of images and algorithms for the fast and efficient processing of recorded images and subsequent analysis facilitated the determination of structures at near-atomic resolution. In this review we will describe sample preparation for cryo-EM, how data are collected by new detectors, and the logistics of image analysis through the basic steps required for reconstructions of both small and large biological complexes and their refinement to nearly atomic resolution. The processing workflow is illustrated using examples of EM analysis of a Type IV Secretion System.
Collapse
|
8
|
Vilas JL, Gómez-Blanco J, Conesa P, Melero R, Miguel de la Rosa-Trevín J, Otón J, Cuenca J, Marabini R, Carazo JM, Vargas J, Sorzano COS. MonoRes: Automatic and Accurate Estimation of Local Resolution for Electron Microscopy Maps. Structure 2018; 26:337-344.e4. [PMID: 29395788 DOI: 10.1016/j.str.2017.12.018] [Citation(s) in RCA: 126] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 10/06/2017] [Accepted: 12/29/2017] [Indexed: 11/29/2022]
Abstract
Since the beginning of electron microscopy, resolution has been a critical parameter. In this article, we propose a fully automatic, accurate method for determining the local resolution of a 3D map (MonoRes). The foundation of this algorithm is an extension of the concept of analytic signal, termed monogenic signal. The map is filtered at different frequencies and the amplitude of the monogenic signal is calculated, after which a criterion is applied to determine the resolution at each voxel. MonoRes is fully automatic without compulsory user parameters, with great accuracy in all tests, and is computationally more rapid than existing methods in the field. In addition, MonoRes offers the option of local filtering of the original map based on the calculated local resolution.
Collapse
Affiliation(s)
- Jose Luis Vilas
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain.
| | - Josué Gómez-Blanco
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain
| | - Pablo Conesa
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain
| | - Roberto Melero
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain
| | | | - Joaquin Otón
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain
| | - Jesús Cuenca
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain
| | - Roberto Marabini
- Escuela Politécnica Superior, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - José María Carazo
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain.
| | - Javier Vargas
- Department of Anatomy and Cell Biology, McGill University, University Street Strathcona Anatomy Building, 3640 Montreal, Canada
| | - Carlos Oscar S Sorzano
- Biocomputing Unit, National Center for Biotechnology (CSIC), Darwin 3, Campus Universidad Autónoma, Cantoblanco, 28049 Madrid, Spain; Department of Engineering of Electronic and Telecommunication Systems, Universidad San Pablo-CEU, Campus Urbanización Montepríncipe, Boadilla del Monte, 28668 Madrid, Spain.
| |
Collapse
|
9
|
Sorzano C, Vargas J, Otón J, Abrishami V, de la Rosa-Trevín J, Gómez-Blanco J, Vilas J, Marabini R, Carazo J. A review of resolution measures and related aspects in 3D Electron Microscopy. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2017; 124:1-30. [DOI: 10.1016/j.pbiomolbio.2016.09.005] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 08/22/2016] [Accepted: 09/18/2016] [Indexed: 12/21/2022]
|
10
|
Belnap DM. Electron Microscopy and Image Processing: Essential Tools for Structural Analysis of Macromolecules. ACTA ACUST UNITED AC 2015; 82:17.2.1-17.2.61. [PMID: 26521712 DOI: 10.1002/0471140864.ps1702s82] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Macromolecular electron microscopy typically depicts the structures of macromolecular complexes ranging from ∼200 kDa to hundreds of MDa. The amount of specimen required, a few micrograms, is typically 100 to 1000 times less than needed for X-ray crystallography or nuclear magnetic resonance spectroscopy. Micrographs of frozen-hydrated (cryogenic) specimens portray native structures, but the original images are noisy. Computational averaging reduces noise, and three-dimensional reconstructions are calculated by combining different views of free-standing particles ("single-particle analysis"). Electron crystallography is used to characterize two-dimensional arrays of membrane proteins and very small three-dimensional crystals. Under favorable circumstances, near-atomic resolutions are achieved. For structures at somewhat lower resolution, pseudo-atomic models are obtained by fitting high-resolution components into the density. Time-resolved experiments describe dynamic processes. Electron tomography allows reconstruction of pleiomorphic complexes and subcellular structures and modeling of macromolecules in their cellular context. Significant information is also obtained from metal-coated and dehydrated specimens.
Collapse
Affiliation(s)
- David M Belnap
- Departments of Biology and Biochemistry, University of Utah, Salt Lake City, Utah
| |
Collapse
|
11
|
Diebolder CA, Faas FGA, Koster AJ, Koning RI. Conical Fourier shell correlation applied to electron tomograms. J Struct Biol 2015; 190:215-23. [PMID: 25843950 DOI: 10.1016/j.jsb.2015.03.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 03/26/2015] [Accepted: 03/27/2015] [Indexed: 11/27/2022]
Abstract
The resolution of electron tomograms is anisotropic due to geometrical constraints during data collection, such as the limited tilt range and single axis tilt series acquisition. Acquisition of dual axis tilt series can decrease these effects. However, in cryo-electron tomography, to limit the electron radiation damage that occurs during imaging, the total dose should not increase and must be fractionated over the two tilt series. Here we set out to determine whether it is beneficial fractionate electron dose for recording dual axis cryo electron tilt series or whether it is better to perform single axis acquisition. To assess the quality of tomographic reconstructions in different directions here we introduce conical Fourier shell correlation (cFSCe/o). Employing cFSCe/o, we compared the resolution isotropy of single-axis and dual-axis (cryo-)electron tomograms using even/odd split data sets. We show that the resolution of dual-axis simulated and cryo-electron tomograms in the plane orthogonal to the electron beam becomes more isotropic compared to single-axis tomograms and high resolution peaks along the tilt axis disappear. cFSCe/o also allowed us to compare different methods for the alignment of dual-axis tomograms. We show that different tomographic reconstruction programs produce different anisotropic resolution in dual axis tomograms. We anticipate that cFSCe/o can also be useful for comparisons of acquisition and reconstruction parameters, and different hardware implementations.
Collapse
Affiliation(s)
- C A Diebolder
- Department of Molecular Cell Biology, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands; Crystal and Structural Chemistry, Bijvoet Center for Biomolecular Research, Department of Chemistry, Faculty of Science, Utrecht University, Padualaan 8, 3584 CH Utrecht, The Netherlands.
| | - F G A Faas
- Department of Molecular Cell Biology, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands.
| | - A J Koster
- Department of Molecular Cell Biology, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands.
| | - R I Koning
- Department of Molecular Cell Biology, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands.
| |
Collapse
|
12
|
Abstract
Validation is a necessity to trust the structures solved by electron microscopy by single particle techniques. The impressive achievements in single particle reconstruction fuel its expansion beyond a small community of image processing experts. This poses the risk of inappropriate data processing with dubious results. Nowhere is it more clearly illustrated than in the recovery of a reference density map from pure noise aligned to that map—a phantom in the noise. Appropriate use of existing validating methods such as resolution-limited alignment and the processing of independent data sets (“gold standard”) avoid this pitfall. However, these methods can be undermined by biases introduced in various subtle ways. How can we test that a map is a coherent structure present in the images selected from the micrographs? In stead of viewing the phantom emerging from noise as a cautionary tale, it should be used as a defining baseline. Any map is always recoverable from noise images, provided a sufficient number of images are aligned and used in reconstruction. However, with smaller numbers of images, the expected coherence in the real particle images should yield better reconstructions than equivalent numbers of noise or background images, even without masking or imposing resolution limits as potential biases. The validation test proposed is therefore a simple alignment of a limited number of micrograph and noise images against the final reconstruction as reference, demonstrating that the micrograph images yield a better reconstruction. I examine synthetic cases to relate the resolution of a reconstruction to the alignment error as a function of the signal-to-noise ratio. I also administered the test to real cases of publicly available data. Adopting such a test can aid the microscopist in assessing the usefulness of the micrographs taken before committing to lengthy processing with questionable outcomes.
Collapse
Affiliation(s)
- J Bernard Heymann
- National Institute of Arthritis and Musculoskeletal and Skin Diseases, National Institutes of Health, 50 South Dr, Bethesda, MD 20892, USA
| |
Collapse
|
13
|
Abstract
Methods for electron tomography of the nematode C. elegans are explained in detail, including a brief introduction to specimen preparation, methods for image collection, and a comparison of several general methods for producing dual-axis tomograms, with or without external fiducial reference objects. New electron tomograms highlight features in software for data display, annotation, and analysis. This chapter discusses the ultrastructural analysis of cells and tissues, rather than molecular studies.
Collapse
Affiliation(s)
- David H Hall
- Albert Einstein College of Medicine, Center for C. elegans Anatomy, 1410 Pelham Parkway South, Room 601, Bronx, NY, 10461, USA.
| | | |
Collapse
|
14
|
Kucukelbir A, Sigworth FJ, Tagare HD. Quantifying the local resolution of cryo-EM density maps. Nat Methods 2014; 11:63-5. [PMID: 24213166 PMCID: PMC3903095 DOI: 10.1038/nmeth.2727] [Citation(s) in RCA: 1385] [Impact Index Per Article: 138.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2013] [Accepted: 10/02/2013] [Indexed: 01/11/2023]
Abstract
We propose a definition of local resolution for three-dimensional electron cryo-microscopy (cryo-EM) density maps that uses local sinusoidal features. Our algorithm has no free parameters and is applicable to other imaging modalities, including tomography. By evaluating the local resolution of single-particle reconstructions and subtomogram averages for four example data sets, we report variable resolution across a 4- to 40-Å range.
Collapse
Affiliation(s)
- Alp Kucukelbir
- Department of Biomedical Engineering, Yale University, New Haven, United States
| | - Fred J. Sigworth
- Department of Biomedical Engineering, Yale University, New Haven, United States
- Department of Cellular and Molecular Physiology, Yale University, New Haven, United States
| | - Hemant D. Tagare
- Department of Biomedical Engineering, Yale University, New Haven, United States
- Department of Diagnostic Radiology, Yale University, New Haven, United States
| |
Collapse
|
15
|
Cardone G, Heymann JB, Steven AC. One number does not fit all: mapping local variations in resolution in cryo-EM reconstructions. J Struct Biol 2013; 184:226-36. [PMID: 23954653 DOI: 10.1016/j.jsb.2013.08.002] [Citation(s) in RCA: 252] [Impact Index Per Article: 22.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 07/31/2013] [Accepted: 08/07/2013] [Indexed: 12/26/2022]
Abstract
The resolution of density maps from single particle analysis is usually measured in terms of the highest spatial frequency to which consistent information has been obtained. This calculation represents an average over the entire reconstructed volume. In practice, however, substantial local variations in resolution may occur, either from intrinsic properties of the specimen or for technical reasons such as a non-isotropic distribution of viewing orientations. To address this issue, we propose the use of a space-frequency representation, the short-space Fourier transform, to assess the quality of a density map, voxel-by-voxel, i.e. by local resolution mapping. In this approach, the experimental volume is divided into small subvolumes and the resolution determined for each of them. It is illustrated in applications both to model data and to experimental density maps. Regions with lower-than-average resolution may be mobile components or ones with incomplete occupancy or result from multiple conformational states. To improve the interpretability of reconstructions, we propose an adaptive filtering approach that reconciles the resolution to which individual features are calculated with the results of the local resolution map.
Collapse
Affiliation(s)
- Giovanni Cardone
- Laboratory of Structural Biology, National Institute for Arthritis, Musculoskeletal and Skin Diseases, National Institutes of Health, Bethesda, MD 20892, USA
| | | | | |
Collapse
|
16
|
Diebolder CA, Koster AJ, Koning RI. Pushing the resolution limits in cryo electron tomography of biological structures. J Microsc 2012; 248:1-5. [PMID: 22670690 DOI: 10.1111/j.1365-2818.2012.03627.x] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Cryo electron tomography is a three-dimensional imaging technique that is suitable for imaging snapshots of the structural arrangements of biomolecular complexes and macromolecules, both in vitro and in the context of the cell. In terms of attainable resolution, cryo electron tomographic reconstructions now show resolvable details in the 5-10 nm range, connecting optical microscopy with molecular imaging techniques. In view of the current developments in super-resolution light microscopy and correlative light and electron microscopy, cryo electron tomography will be increasingly important in structural biology as a tool to bridge light microscopy with molecular imaging techniques like NMR, X-ray diffraction and single particle electron microscopy. In cell biology, one goal, often referred to as visual proteomics, is the molecular mapping of whole cells. To achieve this goal and link cryo electron tomography to these high-resolution techniques, increasing the attainable resolution to 2-5 nm is vital. Here, we provide an overview of technical factors that limit the resolution in cryo electron tomography and discuss how during data acquisition and image processing these can be optimized to attain the highest possible resolution. Also, existing resolution measurement approaches and current technological developments that potentially increase the resolution in cryo electron tomography are discussed.
Collapse
Affiliation(s)
- Christoph A Diebolder
- Molecular Cell Biology, Section Electron Microscopy, Leiden University Medical Center, P.O.Box 9600, 2300 RC, Leiden, The Netherlands
| | | | | |
Collapse
|
17
|
Tanigaki T, Aizawa S, Suzuki T, Tonomura A. Three-dimensional reconstructions of electrostatic potential distributions with 1.5-nm resolution using off-axis electron holography. Microscopy (Oxf) 2012; 61:77-84. [PMID: 22190597 DOI: 10.1093/jmicro/dfr097] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023] Open
Abstract
Three-dimensional (3D) reconstruction experiments were carried out by observing high-resolution 3D electrostatic potential distributions of Pt nanoparticles using off-axis electron holographic tomography. These Pt nanoparticles were mounted on the surfaces of amorphous silicon pillars. In order to realize high-resolution observation, we developed a mechanically stable 3D specimen holder with small specimen drifts and vibrations. From the 3D electrostatic potential distribution data of Pt nanoparticles (2.0 nm in diameter), we obtained the resolution of 1.5 nm.
Collapse
Affiliation(s)
- Toshiaki Tanigaki
- Advanced Science Institute, RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198, Japan.
| | | | | | | |
Collapse
|
18
|
Orlova EV, Saibil HR. Structural analysis of macromolecular assemblies by electron microscopy. Chem Rev 2011; 111:7710-48. [PMID: 21919528 PMCID: PMC3239172 DOI: 10.1021/cr100353t] [Citation(s) in RCA: 126] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2010] [Indexed: 12/11/2022]
Affiliation(s)
- E. V. Orlova
- Crystallography and Institute of Structural and Molecular Biology, Birkbeck College, Malet Street, London WC1E 7HX, United Kingdom
| | - H. R. Saibil
- Crystallography and Institute of Structural and Molecular Biology, Birkbeck College, Malet Street, London WC1E 7HX, United Kingdom
| |
Collapse
|
19
|
Cohen-Krausz S, Cabahug PC, Trachtenberg S. The Monomeric, Tetrameric, and Fibrillar Organization of Fib: The Dynamic Building Block of the Bacterial Linear Motor of Spiroplasma melliferum BC3. J Mol Biol 2011; 410:194-213. [DOI: 10.1016/j.jmb.2011.04.067] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2010] [Revised: 04/18/2011] [Accepted: 04/27/2011] [Indexed: 10/18/2022]
|
20
|
Structure and mechanism of the chromatin remodelling factor ISW1a. Nature 2011; 472:448-53. [PMID: 21525927 DOI: 10.1038/nature09947] [Citation(s) in RCA: 133] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2009] [Accepted: 02/17/2011] [Indexed: 12/24/2022]
Abstract
Site-specific recognition of DNA in eukaryotic organisms depends on the arrangement of nucleosomes in chromatin. In the yeast Saccharomyces cerevisiae, ISW1a and related chromatin remodelling factors are implicated in establishing the nucleosome repeat during replication and altering nucleosome position to affect gene activity. Here we have solved the crystal structures of S. cerevisiae ISW1a lacking its ATPase domain both alone and with DNA bound at resolutions of 3.25 Å and 3.60 Å, respectively, and we have visualized two different nucleosome-containing remodelling complexes using cryo-electron microscopy. The composite X-ray and electron microscopy structures combined with site-directed photocrosslinking analyses of these complexes suggest that ISW1a uses a dinucleosome substrate for chromatin remodelling. Results from a remodelling assay corroborate the dinucleosome model. We show how a chromatin remodelling factor could set the spacing between two adjacent nucleosomes acting as a 'protein ruler'.
Collapse
|
21
|
Liao HY, Frank J. Definition and estimation of resolution in single-particle reconstructions. Structure 2010; 18:768-75. [PMID: 20637413 DOI: 10.1016/j.str.2010.05.008] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2010] [Revised: 04/23/2010] [Accepted: 05/10/2010] [Indexed: 10/19/2022]
Abstract
In this paper, we review current practices for establishing the resolution in single-particle reconstructions. The classical Raleigh criterion for the resolution is not applicable in this case, and the resolution is commonly defined by a consistency test, whereby the data set is randomly split in half and the two resulting reconstructions are then compared. Such a procedure, however, may introduce statistical dependence between the two half-sets, which leads to a too optimistic resolution estimate. On the other hand, this overestimation is counteracted by the diminished statistical properties of a mere half of the data set. The "true" resolution of the whole data set can be estimated when the functional relationship between the data size and the resolution is known. We are able to estimate this functional by taking into account the B-factor and the geometry of data collection. Finally, the drawbacks of resolution estimation are entirely avoided by computing the correlation of neighboring voxels in the Fourier domain.
Collapse
Affiliation(s)
- Hstau Y Liao
- Department of Biochemistry and Molecular Biophysics, Columbia University, New York, NY 10032, USA
| | | |
Collapse
|
22
|
Abstract
Resolution measures in molecular electron microscopy provide means to evaluate quality of macromolecular structures computed from sets of their two-dimensional (2D) line projections. When the amount of detail in the computed density map is low there are no external standards by which the resolution of the result can be judged. Instead, resolution measures in molecular electron microscopy evaluate consistency of the results in reciprocal space and present it as a one-dimensional (1D) function of the modulus of spatial frequency. Here we provide description of standard resolution measures commonly used in electron microscopy. We point out that the organizing principle is the relationship between these measures and the spectral signal-to-noise ratio (SSNR) of the computed density map. Within this framework it becomes straightforward to describe the connection between the outcome of resolution evaluations and the quality of electron microscopy maps, in particular, the optimum filtration, in the Wiener sense, of the computed map. We also provide a discussion of practical difficulties of evaluation of resolution in electron microscopy, particularly in terms of its sensitivity to data processing operations used during structure determination process in single particle analysis and in electron tomography (ET).
Collapse
Affiliation(s)
- Pawel A Penczek
- Department of Biochemistry and Molecular Biology, The University of Texas, Houston Medical School, Houston, Texas, USA
| |
Collapse
|
23
|
Abstract
Single-particle electron microscopy (EM) can provide structural information for a large variety of biological molecules, ranging from small proteins to large macromolecular assemblies, without the need to produce crystals. The year 2008 has become a landmark year for single-particle EM as for the first time density maps have been produced at a resolution that made it possible to trace protein backbones or even to build atomic models. In this review, we highlight some of the recent successes achieved by single-particle EM and describe the individual steps involved in producing a density map by this technique. We also discuss some of the remaining challenges and areas, in which further advances would have a great impact on the results that can be achieved by single-particle EM.
Collapse
Affiliation(s)
- Yifan Cheng
- The W.M. Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California-San Francisco, CA 94158, USA.
| | | |
Collapse
|
24
|
High-resolution single-particle orientation refinement based on spectrally self-adapting common lines. J Struct Biol 2009; 167:83-94. [DOI: 10.1016/j.jsb.2009.04.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2009] [Revised: 04/21/2009] [Accepted: 04/22/2009] [Indexed: 11/23/2022]
|
25
|
Friedrich H, de Jongh PE, Verkleij AJ, de Jong KP. Electron Tomography for Heterogeneous Catalysts and Related Nanostructured Materials. Chem Rev 2009; 109:1613-29. [DOI: 10.1021/cr800434t] [Citation(s) in RCA: 210] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Heiner Friedrich
- Inorganic Chemistry and Catalysis, Debye Institute for Nanomaterials Science, Utrecht University, Sorbonnelaan 16, 3584 CA, Utrecht, The Netherlands, and Molecular Cell Biology, Utrecht University, Padualaan 8, 2584 CH, Utrecht, The Netherlands
| | - Petra E. de Jongh
- Inorganic Chemistry and Catalysis, Debye Institute for Nanomaterials Science, Utrecht University, Sorbonnelaan 16, 3584 CA, Utrecht, The Netherlands, and Molecular Cell Biology, Utrecht University, Padualaan 8, 2584 CH, Utrecht, The Netherlands
| | - Arie J. Verkleij
- Inorganic Chemistry and Catalysis, Debye Institute for Nanomaterials Science, Utrecht University, Sorbonnelaan 16, 3584 CA, Utrecht, The Netherlands, and Molecular Cell Biology, Utrecht University, Padualaan 8, 2584 CH, Utrecht, The Netherlands
| | - Krijn P. de Jong
- Inorganic Chemistry and Catalysis, Debye Institute for Nanomaterials Science, Utrecht University, Sorbonnelaan 16, 3584 CA, Utrecht, The Netherlands, and Molecular Cell Biology, Utrecht University, Padualaan 8, 2584 CH, Utrecht, The Netherlands
| |
Collapse
|
26
|
Karmali AM, Blundell TL, Furnham N. Model-building strategies for low-resolution X-ray crystallographic data. ACTA CRYSTALLOGRAPHICA SECTION D: BIOLOGICAL CRYSTALLOGRAPHY 2009; 65:121-7. [PMID: 19171966 PMCID: PMC2631632 DOI: 10.1107/s0907444908040006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2008] [Accepted: 11/27/2008] [Indexed: 11/24/2022]
Abstract
Interpretation of low-resolution X-ray crystallographic data can prove to be a difficult task. The challenges faced in electron-density interpretation, the strategies that have been employed to overcome them and developments to automate the process are reviewed. The interpretation of low-resolution X-ray crystallographic data proves to be challenging even for the most experienced crystallographer. Ambiguity in the electron-density map makes main-chain tracing and side-chain assignment difficult. However, the number of structures solved at resolutions poorer than 3.5 Å is growing rapidly and the structures are often of high biological interest and importance. Here, the challenges faced in electron-density interpretation, the strategies that have been employed to overcome them and developments to automate the process are reviewed. The methods employed in model generation from electron microscopy, which share many of the same challenges in providing high-confidence models of macromolecular structures and assemblies, are also considered.
Collapse
Affiliation(s)
- Anjum M Karmali
- Department of Biochemistry, University of Cambridge, Cambridge, England
| | | | | |
Collapse
|
27
|
JONIĆ S, SORZANO C, BOISSET N. Comparison of single-particle analysis and electron tomography approaches: an overview. J Microsc 2008; 232:562-79. [DOI: 10.1111/j.1365-2818.2008.02119.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
28
|
Scheres SHW, Núñez-Ramírez R, Sorzano COS, Carazo JM, Marabini R. Image processing for electron microscopy single-particle analysis using XMIPP. Nat Protoc 2008; 3:977-90. [PMID: 18536645 DOI: 10.1038/nprot.2008.62] [Citation(s) in RCA: 291] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We describe a collection of standardized image processing protocols for electron microscopy single-particle analysis using the XMIPP software package. These protocols allow performing the entire processing workflow starting from digitized micrographs up to the final refinement and evaluation of 3D models. A particular emphasis has been placed on the treatment of structurally heterogeneous data through maximum-likelihood refinements and self-organizing maps as well as the generation of initial 3D models for such data sets through random conical tilt reconstruction methods. All protocols presented have been implemented as stand-alone, executable python scripts, for which a dedicated graphical user interface has been developed. Thereby, they may provide novice users with a convenient tool to quickly obtain useful results with minimum efforts in learning about the details of this comprehensive package. Examples of applications are presented for a negative stain random conical tilt data set on the hexameric helicase G40P and for a structurally heterogeneous data set on 70S Escherichia coli ribosomes embedded in vitrified ice.
Collapse
Affiliation(s)
- Sjors H W Scheres
- Centro Nacional de Biotecnología CSIC, Unidad de Biocomputación, Cantoblanco, 28049 Madrid, Spain
| | | | | | | | | |
Collapse
|
29
|
Abstract
![]()
The objective of molecular electron microscopy (EM) is to use electron
microscopes to visualize the structure of biological molecules. This
Review provides a brief overview of the methods used in molecular
EM, their respective strengths and successes, and current developments
that promise an even more exciting future for molecular EM in the
structural investigation of proteins and macromolecular complexes,
studied in isolation or in the context of cells and tissues.
Collapse
Affiliation(s)
- Henning Stahlberg
- Molecular and Cellular Biology,
College of Biological Sciences, University of California at Davis,
Briggs Hall, 1 Shields Avenue, Davis, California 95616
| | - Thomas Walz
- Department of Cell Biology, Harvard Medical School, 240 Longwood Avenue, Boston, Massachusetts 02115
| |
Collapse
|
30
|
Sorzano C, Velázquez-Muriel J, Marabini R, Herman G, Carazo J. Volumetric restrictions in single particle 3DEM reconstruction. PATTERN RECOGNITION 2008; 41:616. [PMID: 20119498 PMCID: PMC2812911 DOI: 10.1016/j.patcog.2007.06.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
3D electron microsscopy aims at the reconstruction of density volumes corresponding to the electrostatic potential distribution of macro-molecules. There are many factors limiting the resolution achievable when this technique is applied to biological macromolecules: microscope imperfections, molecule flexibility, lack of projections from certain directions, unknown angular distribution, noise, etc. In this communication we explore the quality gain in the reconstruction by including a priori knowledge such as particle symmetry, occupied volume, known surface relief, density nonnegativity and similarity to a known volume in order to improve the quality of the reconstruction. If the reconstruction is represented as a series expansion, such constraints can be expressed by set of equations that the expansion coefficients must satisfy. In this work, these equation sets are specified and combined in a novel way with the ART + blobs reconstruction algorithm. The effect of each one on the reconstruction of a realistic phantom is explored. Finally, the application of these restrictions to 3D reconstructions from experimental data are studied.
Collapse
Affiliation(s)
- C.O.S. Sorzano
- Unidad de Biocomputación, Centro Nacional de Biotecnología (CSIC), Campus Universidad Autónoma s/n, 28049 Cantoblanco, Madrid, Spain
- Dept. Ingeniería de Sistemas Electrónicos y de Telecomunicación, Escuela Politécnica Superior, Univ. San Pablo—CEU, Campus Urb. Montepríncipe s/n, 28668 Boadilla del Monte, Madrid, Spain
| | - J.A. Velázquez-Muriel
- Unidad de Biocomputación, Centro Nacional de Biotecnología (CSIC), Campus Universidad Autónoma s/n, 28049 Cantoblanco, Madrid, Spain
| | - R. Marabini
- Dept. Informática, Escuela Politécnica Superior, c/Francisco Tomás y Valiente, 11, Universidad Autónoma, 28049 Cantoblanco, Madrid, Spain
| | - G.T. Herman
- Department of Computer Science, The Graduate Center, The City University of New York, New York, NY 10016, USA
| | - J.M. Carazo
- Unidad de Biocomputación, Centro Nacional de Biotecnología (CSIC), Campus Universidad Autónoma s/n, 28049 Cantoblanco, Madrid, Spain
| |
Collapse
|
31
|
McEwen BF, Renken C, Marko M, Mannella C. Chapter 6 Principles and Practice in Electron Tomography. Methods Cell Biol 2008; 89:129-68. [DOI: 10.1016/s0091-679x(08)00606-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
32
|
Scheres SHW, Núñez-Ramírez R, Gómez-Llorente Y, San Martín C, Eggermont PPB, Carazo JM. Modeling experimental image formation for likelihood-based classification of electron microscopy data. Structure 2007; 15:1167-77. [PMID: 17937907 DOI: 10.1016/j.str.2007.09.003] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2007] [Revised: 08/18/2007] [Accepted: 09/01/2007] [Indexed: 11/15/2022]
Abstract
The coexistence of multiple distinct structural states often obstructs the application of three-dimensional cryo-electron microscopy to large macromolecular complexes. Maximum likelihood approaches are emerging as robust tools for solving the image classification problems that are posed by such samples. Here, we propose a statistical data model that allows for a description of the experimental image formation within the formulation of 2D and 3D maximum-likelihood refinement. The proposed approach comprises a formulation of the probability calculations in Fourier space, including a spatial frequency-dependent noise model and a description of defocus-dependent imaging effects. The Expectation-Maximization-like algorithms presented are generally applicable to the alignment and classification of structurally heterogeneous projection data. Their effectiveness is demonstrated with various examples, including 2D classification of top views of the archaeal helicase MCM and 3D classification of 70S E. coli ribosome and Simian Virus 40 large T-antigen projections.
Collapse
Affiliation(s)
- Sjors H W Scheres
- Centro Nacional de Biotecnología CSIC, Cantoblanco, 28049, Madrid, Spain
| | | | | | | | | | | |
Collapse
|
33
|
Sorzano COS, Jonic S, Cottevieille M, Larquet E, Boisset N, Marco S. 3D electron microscopy of biological nanomachines: principles and applications. EUROPEAN BIOPHYSICS JOURNAL: EBJ 2007; 36:995-1013. [PMID: 17611751 DOI: 10.1007/s00249-007-0203-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2007] [Revised: 06/01/2007] [Accepted: 06/11/2007] [Indexed: 11/21/2022]
Abstract
Transmission electron microscopy is a powerful technique for studying the three-dimensional (3D) structure of a wide range of biological specimens. Knowledge of this structure is crucial for fully understanding complex relationships among macromolecular complexes and organelles in living cells. In this paper, we present the principles and main application domains of 3D transmission electron microscopy in structural biology. Moreover, we survey current developments needed in this field, and discuss the close relationship of 3D transmission electron microscopy with other experimental techniques aimed at obtaining structural and dynamical information from the scale of whole living cells to atomic structure of macromolecular complexes.
Collapse
Affiliation(s)
- C O S Sorzano
- Bioengineering Lab, Escuela Politécnica Superior, Univ. San Pablo CEU, Campus Urb, Montepríncipe s/n, 28668, Boadilla del Monte, Madrid, Spain.
| | | | | | | | | | | |
Collapse
|
34
|
Zhang HB, Zhang XL, Wang Y, Takaoka A. Tomography experiment of an integrated circuit specimen using 3 MeV electrons in the transmission electron microscope. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2007; 78:013701. [PMID: 17503922 DOI: 10.1063/1.2409864] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The possibility of utilizing high-energy electron tomography to characterize the micron-scale three dimensional (3D) structures of integrated circuits has been demonstrated experimentally. First, electron transmission through a tilted SiO(2) film was measured with an ultrahigh-voltage electron microscope (ultra-HVEM) and analyzed from the point of view of elastic scattering of electrons, showing that linear attenuation of the logarithmic electron transmission still holds valid for effective specimen thicknesses up to 5 microm under 2 MV accelerating voltages. Electron tomography of a micron-order thick integrated circuit specimen including the Cu/via interconnect was then tried with 3 MeV electrons in the ultra-HVEM. Serial projection images of the specimen tilted at different angles over the range of +/-90 degrees were acquired, and 3D reconstruction was performed with the images by means of the IMOD software package. Consequently, the 3D structures of the Cu lines, via and void, were revealed by cross sections and surface rendering.
Collapse
Affiliation(s)
- Hai-Bo Zhang
- Department of Electronic Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
| | | | | | | |
Collapse
|
35
|
Abstract
Here we propose a novel method for automatic, markerless, feature-based alignment of TEM images suitable for electron tomography. The proposed method, termed trifocal alignment, is more accurate than the previous markerless methods. The key components developed are: (1) a reliable multi-resolution algorithm for matching feature points between images; (2) a robust, maximum-likelihood-based estimator for determining the geometry of three views--the trifocal constraint--required for validating the correctness of the matches; and (3) a robust, large-scale optimization framework to compute the alignment parameters from hundreds of thousands of feature point measurements from a few hundred images. The ability to utilize such a large number of measurements successfully compensates for point localization errors. The method was experimentally confirmed with electron tomography tilt series of biological and material sciences samples, consisting of from 40 to 150 images. The results show that, with this feature-based alignment approach, a level of accuracy comparable with fiducial marker alignment can be achieved.
Collapse
Affiliation(s)
- S S Brandt
- Laboratory of Computational Engineering, Helsinki University of Technology, PO Box 9203, FI-02015 TKK, Finland.
| | | |
Collapse
|
36
|
Gómez-Llorente Y, Fletcher RJ, Chen XS, Carazo JM, San Martín C. Polymorphism and double hexamer structure in the archaeal minichromosome maintenance (MCM) helicase from Methanobacterium thermoautotrophicum. J Biol Chem 2005; 280:40909-15. [PMID: 16221680 DOI: 10.1074/jbc.m509760200] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Methanobacterium thermoautotrophicum minichromosome maintenance complex (mtMCM), a cellular replicative helicase, is a useful model for the more complex eukaryotic MCMs. Biochemical and crystallographic evidence indicates that mtMCM assembles as a double hexamer (dHex), but previous electron microscopy studies reported only the presence of single heptamers or single hexamers (Pape, T., Meka, H., Chen, S., Vicentini, G., Van Heel, M., and Onesti, S. (2003) EMBO Rep. 4, 1079-1083; Yu, X., VanLoock, M. S., Poplawski, A., Kelman, Z., Xiang, T., Tye, B. K., and Egelman, E. H. (2002) EMBO Rep. 3, 792-797). Here we present the first three-dimensional electron microscopy reconstruction of the full-length mtMCM dHex in which two hexamers contact each other via the structurally well defined N-terminal domains. The dHex has obvious side openings that resemble the side channels of LTag (large T antigen). 6-fold and 7-fold rings were observed in the same mtMCM preparation, but we determined that assembly as a double ring favors 6-fold structures. Additionally, open rings were also detected, which suggests a direct mtMCM loading mechanism onto DNA.
Collapse
Affiliation(s)
- Yacob Gómez-Llorente
- Biocomputing Unit, Centro Nacional de Biotecnología, Consejo Superior de Investigaciones Científicas, Darwin 3, 28049 Madrid, Spain
| | | | | | | | | |
Collapse
|
37
|
Jiang W, Ludtke SJ. Electron cryomicroscopy of single particles at subnanometer resolution. Curr Opin Struct Biol 2005; 15:571-7. [PMID: 16140524 DOI: 10.1016/j.sbi.2005.08.004] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2005] [Revised: 07/09/2005] [Accepted: 08/24/2005] [Indexed: 11/24/2022]
Abstract
Electron cryomicroscopy and single-particle reconstruction have advanced substantially over the past two decades. There are now numerous examples of structures that have been solved using this technique to better than 10 A resolution. At such resolutions, direct identification of alpha helices is possible and, often, beta-sheet-containing regions can be identified. The most numerous subnanometer resolution structures are the icosahedral viruses, as higher resolution is easier to achieve with higher symmetry. Important non-icosahedral structures solved to subnanometer resolution include several ribosome structures, clathrin assemblies and, most recently, the Ca2+ release channel. There is now hope that, in the next few years, this technique will achieve resolutions approaching 4 A, permitting a complete trace of the protein backbone without reference to a crystal structure.
Collapse
Affiliation(s)
- Wen Jiang
- National Center for Macromolecular Imaging, Verna and Marrs McLean Department of Biochemistry and Molecular Biology, Baylor College of Medicine, Houston, TX 77030, USA
| | | |
Collapse
|