1
|
Arsana KGY, Saladino GM, Brodin B, Toprak MS, Hertz HM. Laboratory Liquid-Jet X-ray Microscopy and X-ray Fluorescence Imaging for Biomedical Applications. Int J Mol Sci 2024; 25:920. [PMID: 38255992 PMCID: PMC10815599 DOI: 10.3390/ijms25020920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/30/2023] [Accepted: 01/08/2024] [Indexed: 01/24/2024] Open
Abstract
Diffraction-limited resolution and low penetration depth are fundamental constraints in optical microscopy and in vivo imaging. Recently, liquid-jet X-ray technology has enabled the generation of X-rays with high-power intensities in laboratory settings. By allowing the observation of cellular processes in their natural state, liquid-jet soft X-ray microscopy (SXM) can provide morphological information on living cells without staining. Furthermore, X-ray fluorescence imaging (XFI) permits the tracking of contrast agents in vivo with high elemental specificity, going beyond attenuation contrast. In this study, we established a methodology to investigate nanoparticle (NP) interactions in vitro and in vivo, solely based on X-ray imaging. We employed soft (0.5 keV) and hard (24 keV) X-rays for cellular studies and preclinical evaluations, respectively. Our results demonstrated the possibility of localizing NPs in the intracellular environment via SXM and evaluating their biodistribution with in vivo multiplexed XFI. We envisage that laboratory liquid-jet X-ray technology will significantly contribute to advancing our understanding of biological systems in the field of nanomedical research.
Collapse
Affiliation(s)
| | | | | | | | - Hans M. Hertz
- Department of Applied Physics, Biomedical and X-ray Physics, KTH Royal Institute of Technology, 10691 Stockholm, Sweden (G.M.S.)
| |
Collapse
|
2
|
Cooper C, Thompson RCA, Clode PL. Investigating parasites in three dimensions: trends in volume microscopy. Trends Parasitol 2023; 39:668-681. [PMID: 37302958 DOI: 10.1016/j.pt.2023.05.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/17/2023] [Accepted: 05/17/2023] [Indexed: 06/13/2023]
Abstract
To best understand parasite, host, and vector morphologies, host-parasite interactions, and to develop new drug and vaccine targets, structural data should, ideally, be obtained and visualised in three dimensions (3D). Recently, there has been a significant uptake of available 3D volume microscopy techniques that allow collection of data across centimetre (cm) to Angstrom (Å) scales by utilising light, X-ray, electron, and ion sources. Here, we present and discuss microscopy tools available for the collection of 3D structural data, focussing on electron microscopy-based techniques. We highlight their strengths and limitations, such that parasitologists can identify techniques best suited to answer their research questions. Additionally, we review the importance of volume microscopy to the advancement of the field of parasitology.
Collapse
Affiliation(s)
- Crystal Cooper
- Centre for Microscopy, Characterisation, and Analysis, University of Western Australia, Stirling Hwy, Crawley, WA 6009, Australia.
| | - R C Andrew Thompson
- School of Veterinary and Life Sciences, Murdoch University, 90 South Street, Murdoch, WA 6150, Australia
| | - Peta L Clode
- Centre for Microscopy, Characterisation, and Analysis, University of Western Australia, Stirling Hwy, Crawley, WA 6009, Australia; School of Biological Sciences, University of Western Australia, Stirling Hwy, Crawley, WA 6009, Australia
| |
Collapse
|
3
|
Chen JH, Vanslembrouck B, Ekman A, Aho V, Larabell CA, Le Gros MA, Vihinen-Ranta M, Weinhardt V. Soft X-ray Tomography Reveals HSV-1-Induced Remodeling of Human B Cells. Viruses 2022; 14:2651. [PMID: 36560654 PMCID: PMC9781670 DOI: 10.3390/v14122651] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 11/29/2022] Open
Abstract
Upon infection, viruses hijack the cell machinery and remodel host cell structures to utilize them for viral proliferation. Since viruses are about a thousand times smaller than their host cells, imaging virus-host interactions at high spatial resolution is like looking for a needle in a haystack. Scouting gross cellular changes with fluorescent microscopy is only possible for well-established viruses, where fluorescent tagging is developed. Soft X-ray tomography (SXT) offers 3D imaging of entire cells without the need for chemical fixation or labeling. Here, we use full-rotation SXT to visualize entire human B cells infected by the herpes simplex virus 1 (HSV-1). We have mapped the temporospatial remodeling of cells during the infection and observed changes in cellular structures, such as the presence of cytoplasmic stress granules and multivesicular structures, formation of nuclear virus-induced dense bodies, and aggregates of capsids. Our results demonstrate the power of SXT imaging for scouting virus-induced changes in infected cells and understanding the orchestration of virus-host remodeling quantitatively.
Collapse
Affiliation(s)
- Jian-Hua Chen
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, USA
| | - Bieke Vanslembrouck
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, USA
| | - Axel Ekman
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Vesa Aho
- Department of Biological and Environmental Science, Nanoscience Center, University of Jyvaskyla, 40014 Jyvaskyla, Finland
| | - Carolyn A. Larabell
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, USA
| | - Mark A. Le Gros
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, USA
| | - Maija Vihinen-Ranta
- Department of Biological and Environmental Science, Nanoscience Center, University of Jyvaskyla, 40014 Jyvaskyla, Finland
| | - Venera Weinhardt
- Centre for Organismal Studies, University of Heidelberg, 69120 Heidelberg, Germany
| |
Collapse
|
4
|
Li A, Zhang S, Loconte V, Liu Y, Ekman A, Thompson GJ, Sali A, Stevens RC, White K, Singla J, Sun L. An intensity-based post-processing tool for 3D instance segmentation of organelles in soft X-ray tomograms. PLoS One 2022; 17:e0269887. [PMID: 36048824 PMCID: PMC9436087 DOI: 10.1371/journal.pone.0269887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 05/29/2022] [Indexed: 11/29/2022] Open
Abstract
Investigating the 3D structures and rearrangements of organelles within a single cell is critical for better characterizing cellular function. Imaging approaches such as soft X-ray tomography have been widely applied to reveal a complex subcellular organization involving multiple inter-organelle interactions. However, 3D segmentation of organelle instances has been challenging despite its importance in organelle characterization. Here we propose an intensity-based post-processing tool to identify and separate organelle instances. Our tool separates sphere-like (insulin vesicle) and columnar-shaped organelle instances (mitochondrion) based on the intensity of raw tomograms, semantic segmentation masks, and organelle morphology. We validate our tool using synthetic tomograms of organelles and experimental tomograms of pancreatic β-cells to separate insulin vesicle and mitochondria instances. As compared to the commonly used connected regions labeling, watershed, and watershed + Gaussian filter methods, our tool results in improved accuracy in identifying organelles in the synthetic tomograms and an improved description of organelle structures in β-cell tomograms. In addition, under different experimental treatment conditions, significant changes in volumes and intensities of both insulin vesicle and mitochondrion are observed in our instance results, revealing their potential roles in maintaining normal β-cell function. Our tool is expected to be applicable for improving the instance segmentation of other images obtained from different cell types using multiple imaging modalities.
Collapse
Affiliation(s)
- Angdi Li
- iHuman Institute, ShanghaiTech University, Shanghai, China
- School of Life Science and Technology, ShanghaiTech University, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Shuning Zhang
- iHuman Institute, ShanghaiTech University, Shanghai, China
- School of Life Science and Technology, ShanghaiTech University, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Valentina Loconte
- iHuman Institute, ShanghaiTech University, Shanghai, China
- School of Life Science and Technology, ShanghaiTech University, Shanghai, China
| | - Yan Liu
- iHuman Institute, ShanghaiTech University, Shanghai, China
- School of Life Science and Technology, ShanghaiTech University, Shanghai, China
| | - Axel Ekman
- Department of Anatomy, University of California San Francisco, San Francisco, CA, United States of America
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America
| | | | - Andrej Sali
- California Institute for Quantitative Biosciences, Department of Bioengineering and Therapeutic Sciences, Department of Pharmaceutical Chemistry, University of California, San Francisco, San Francisco, CA, United States of America
| | - Raymond C. Stevens
- iHuman Institute, ShanghaiTech University, Shanghai, China
- School of Life Science and Technology, ShanghaiTech University, Shanghai, China
- Department of Biological Sciences, Bridge Institute, University of Southern California, Los Angeles, CA, United States of America
- Department of Chemistry, Bridge Institute, University of Southern California, Los Angeles, CA, United States of America
| | - Kate White
- Department of Chemistry, Bridge Institute, University of Southern California, Los Angeles, CA, United States of America
- * E-mail: (KW); (JS); (LS)
| | - Jitin Singla
- Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
- * E-mail: (KW); (JS); (LS)
| | - Liping Sun
- iHuman Institute, ShanghaiTech University, Shanghai, China
- School of Life Science and Technology, ShanghaiTech University, Shanghai, China
- * E-mail: (KW); (JS); (LS)
| |
Collapse
|
5
|
Loetgering L, Witte S, Rothhardt J. Advances in laboratory-scale ptychography using high harmonic sources [Invited]. OPTICS EXPRESS 2022; 30:4133-4164. [PMID: 35209658 DOI: 10.1364/oe.443622] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/22/2021] [Indexed: 06/14/2023]
Abstract
Extreme ultraviolet microscopy and wavefront sensing are key elements for next-generation ultrafast applications, such as chemically-resolved imaging, focal spot diagnostics in pump-and-probe experiments, and actinic metrology for the state-of-the-art lithography node at 13.5 nm wavelength. Ptychography offers a robust solution to the aforementioned challenges. Originally adapted by the electron and synchrotron communities, advances in the stability and brightness of high-harmonic tabletop sources have enabled the transfer of ptychography to the laboratory. This review covers the state of the art in tabletop ptychography with high harmonic generation sources. We consider hardware options such as illumination optics and detector concepts as well as algorithmic aspects in the analysis of multispectral ptychography data. Finally, we review technological application cases such as multispectral wavefront sensing, attosecond pulse characterization, and depth-resolved imaging.
Collapse
|
6
|
Loconte V, Chen JH, Cortese M, Ekman A, Le Gros MA, Larabell C, Bartenschlager R, Weinhardt V. Using soft X-ray tomography for rapid whole-cell quantitative imaging of SARS-CoV-2-infected cells. CELL REPORTS METHODS 2021; 1:100117. [PMID: 34729550 PMCID: PMC8552653 DOI: 10.1016/j.crmeth.2021.100117] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 09/10/2021] [Accepted: 10/22/2021] [Indexed: 02/08/2023]
Abstract
High-resolution and rapid imaging of host cell ultrastructure can generate insights toward viral disease mechanism, for example for a severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection. Here, we employ full-rotation soft X-ray tomography (SXT) to examine organelle remodeling induced by SARS-CoV-2 at the whole-cell level with high spatial resolution and throughput. Most of the current SXT systems suffer from a restricted field of view due to use of flat sample supports and artifacts due to missing data. In this approach using cylindrical sample holders, a full-rotation tomogram of human lung epithelial cells is performed in less than 10 min. We demonstrate the potential of SXT imaging by visualizing aggregates of SARS-CoV-2 virions and virus-induced intracellular alterations. This rapid whole-cell imaging approach allows us to visualize the spatiotemporal changes of cellular organelles upon viral infection in a quantitative manner.
Collapse
Affiliation(s)
- Valentina Loconte
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
- Department of Anatomy, University of California, San Francisco, San Francisco, CA, USA
| | - Jian-Hua Chen
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
- Department of Anatomy, University of California, San Francisco, San Francisco, CA, USA
| | - Mirko Cortese
- Department of Infectious Diseases, Molecular Virology Heidelberg University, Heidelberg, Germany
| | - Axel Ekman
- Department of Anatomy, University of California, San Francisco, San Francisco, CA, USA
| | - Mark A. Le Gros
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
- Department of Anatomy, University of California, San Francisco, San Francisco, CA, USA
| | - Carolyn Larabell
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
- Department of Anatomy, University of California, San Francisco, San Francisco, CA, USA
| | - Ralf Bartenschlager
- Department of Infectious Diseases, Molecular Virology Heidelberg University, Heidelberg, Germany
- German Center for Infection Research, Heidelberg Partner Site, Heidelberg, Germany
- Division Virus-Associated Carcinogenesis, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Venera Weinhardt
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
- Centre for Organismal Studies, Heidelberg University, Heidelberg, Germany
| |
Collapse
|
7
|
Table-Top Water-Window Microscope Using a Capillary Discharge Plasma Source with Spatial Resolution 75 nm. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10186373] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
We present a design of a compact transmission water-window microscope based on the Z-pinching capillary discharge nitrogen plasma source. The microscope operates at wavelength of 2.88 nm (430 eV), and with its table-top dimensions provides an alternative to large-scale soft X-ray (SXR) microscope systems based on synchrotrons and free-electron lasers. The emitted soft X-ray radiation is filtered by a titanium foil and focused by an ellipsoidal condenser mirror into the sample plane. A Fresnel zone plate was used to create a transmission image of the sample onto a charge-coupled device (CCD) camera. To assess the resolution of the microscope, we imaged a standard sample-copper mesh. The spatial resolution of the microscope is 75 nm at half-pitch, calculated via a 10–90% intensity knife-edge test. The applicability of the microscope is demonstrated by the imaging of green algae-Desmodesmus communis. This paper describes the principle of capillary discharge source, design of the microscope, and experimental imaging results of Cu mesh and biological sample.
Collapse
|
8
|
Leontowich AFG, Berg R, Regier CN, Taylor DM, Wang J, Beauregard D, Geilhufe J, Swirsky J, Wu J, Karunakaran C, Hitchcock AP, Urquhart SG. Cryo scanning transmission x-ray microscope optimized for spectrotomography. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:093704. [PMID: 30278741 DOI: 10.1063/1.5041009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Accepted: 08/17/2018] [Indexed: 06/08/2023]
Abstract
A cryo scanning transmission X-ray microscope, the cryo-STXM, has been designed and commissioned at the Canadian Light Source synchrotron. The instrument is designed to operate from 100 to 4000 eV (λ = 12.4 - 0.31 nm). Users can insert a previously frozen sample, through a load lock, and rotate it ±70° in the beam to collect tomographic data sets. The sample can be maintained for extended periods at 92 K primarily to suppress radiation damage and a pressure on the order of 10-9 Torr to suppress sample contamination. The achieved spatial resolution (30 nm) and spectral resolution (0.1 eV) are similar to other current soft X-ray STXMs, as demonstrated by measurements on known samples and test patterns. The data acquisition efficiency is significantly more favorable for both imaging and tomography. 2D images, 3D tomograms, and 4D chemical maps of automotive hydrogen fuel cell thin sections are presented to demonstrate current performance and new capabilities, namely, cryo-spectrotomography in the soft X-ray region.
Collapse
Affiliation(s)
- A F G Leontowich
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - R Berg
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - C N Regier
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - D M Taylor
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - J Wang
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - D Beauregard
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - J Geilhufe
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - J Swirsky
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - J Wu
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - C Karunakaran
- Canadian Light Source, Inc., Saskatoon, Saskatchewan S7N 2V3, Canada
| | - A P Hitchcock
- Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - S G Urquhart
- Department of Chemistry, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5C9, Canada
| |
Collapse
|
9
|
Ekman A, Weinhardt V, Chen JH, McDermott G, Le Gros MA, Larabell C. PSF correction in soft X-ray tomography. J Struct Biol 2018; 204:9-18. [PMID: 29908247 DOI: 10.1016/j.jsb.2018.06.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 06/05/2018] [Accepted: 06/07/2018] [Indexed: 11/29/2022]
Abstract
In this article, we introduce a linear approximation of the forward model of soft X-ray tomography, such that the reconstruction is solvable by standard iterative schemes. This linear model takes into account the three-dimensional point spread function (PSF) of the optical system, which consequently enhances the reconstruction of data. The feasibility of the model is demonstrated on both simulated and experimental data, based on theoretically estimated and experimentally measured PSFs.
Collapse
Affiliation(s)
- Axel Ekman
- Department of Anatomy, University of California, San Francisco, CA 94143, USA
| | - Venera Weinhardt
- Department of Anatomy, University of California, San Francisco, CA 94143, USA; Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Jian-Hua Chen
- Department of Anatomy, University of California, San Francisco, CA 94143, USA
| | - Gerry McDermott
- Department of Anatomy, University of California, San Francisco, CA 94143, USA
| | - Mark A Le Gros
- Department of Anatomy, University of California, San Francisco, CA 94143, USA; Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Carolyn Larabell
- Department of Anatomy, University of California, San Francisco, CA 94143, USA; Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA.
| |
Collapse
|
10
|
Abstract
Water-window x-ray microscopy allows two- and three-dimensional (2D and 3D) imaging of intact unstained cells in their cryofixed near-native state with unique contrast and high resolution. Present operational biological water-window microscopes are based at synchrotron facilities, which limits their accessibility and integration with complementary methods. Laboratory-source microscopes have had difficulty addressing relevant biological tasks with proper resolution and contrast due to long exposure times and limited up-time. Here we report on laboratory cryo x-ray microscopy with the exposure time, contrast, and reliability to allow for routine high-spatial resolution 3D imaging of intact cells and cell-cell interactions. Stabilization of the laser-plasma source combined with new optics and sample preparation provide high-resolution cell imaging, both in 2D with ten-second exposures and in 3D with twenty-minute tomography. Examples include monitoring of the distribution of carbon-dense vesicles in starving HEK293T cells and imaging the interaction between natural killer cells and target cells.
Collapse
|
11
|
Li Q, Gluch J, Krüger P, Gall M, Neinhuis C, Zschech E. Pollen structure visualization using high-resolution laboratory-based hard X-ray tomography. Biochem Biophys Res Commun 2016; 479:272-276. [PMID: 27639647 DOI: 10.1016/j.bbrc.2016.09.058] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2016] [Accepted: 09/12/2016] [Indexed: 11/25/2022]
Abstract
A laboratory-based X-ray microscope is used to investigate the 3D structure of unstained whole pollen grains. For the first time, high-resolution laboratory-based hard X-ray microscopy is applied to study pollen grains. Based on the efficient acquisition of statistically relevant information-rich images using Zernike phase contrast, both surface- and internal structures of pine pollen - including exine, intine and cellular structures - are clearly visualized. The specific volumes of these structures are calculated from the tomographic data. The systematic three-dimensional study of pollen grains provides morphological and structural information about taxonomic characters that are essential in palynology. Such studies have a direct impact on disciplines such as forestry, agriculture, horticulture, plant breeding and biodiversity.
Collapse
Affiliation(s)
- Qiong Li
- Fraunhofer-Institut für Keramische Technologien und Systeme, Maria-Reiche-Straße 2, 01109, Dresden, Germany.
| | - Jürgen Gluch
- Fraunhofer-Institut für Keramische Technologien und Systeme, Maria-Reiche-Straße 2, 01109, Dresden, Germany
| | - Peter Krüger
- Fraunhofer-Institut für Keramische Technologien und Systeme, Maria-Reiche-Straße 2, 01109, Dresden, Germany
| | - Martin Gall
- Fraunhofer-Institut für Keramische Technologien und Systeme, Maria-Reiche-Straße 2, 01109, Dresden, Germany
| | - Christoph Neinhuis
- Department of Biology, Technische Universität Dresden, Zellescher Weg 20b, 01062, Dresden, Germany
| | - Ehrenfried Zschech
- Fraunhofer-Institut für Keramische Technologien und Systeme, Maria-Reiche-Straße 2, 01109, Dresden, Germany
| |
Collapse
|
12
|
Do M, Isaacson SA, McDermott G, Le Gros MA, Larabell CA. Imaging and characterizing cells using tomography. Arch Biochem Biophys 2015; 581:111-21. [PMID: 25602704 PMCID: PMC4506273 DOI: 10.1016/j.abb.2015.01.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2014] [Revised: 12/29/2014] [Accepted: 01/11/2015] [Indexed: 12/11/2022]
Abstract
We can learn much about cell function by imaging and quantifying sub-cellular structures, especially if this is done non-destructively without altering said structures. Soft X-ray tomography (SXT) is a high-resolution imaging technique for visualizing cells and their interior structure in 3D. A tomogram of the cell, reconstructed from a series of 2D projection images, can be easily segmented and analyzed. SXT has a very high specimen throughput compared to other high-resolution structure imaging modalities; for example, tomographic data for reconstructing an entire eukaryotic cell is acquired in a matter of minutes. SXT visualizes cells without the need for chemical fixation, dehydration, or staining of the specimen. As a result, the SXT reconstructions are close representations of cells in their native state. SXT is applicable to most cell types. The deep penetration of soft X-rays allows cells, even mammalian cells, to be imaged without being sectioned. Image contrast in SXT is generated by the differential attenuation soft X-ray illumination as it passes through the specimen. Accordingly, each voxel in the tomographic reconstruction has a measured linear absorption coefficient (LAC) value. LAC values are quantitative and give rise to each sub-cellular component having a characteristic LAC profile, allowing organelles to be identified and segmented from the milieu of other cell contents. In this chapter, we describe the fundamentals of SXT imaging and how this technique can answer real world questions in the study of the nucleus. We also describe the development of correlative methods for the localization of specific molecules in a SXT reconstruction. The combination of fluorescence and SXT data acquired from the same specimen produces composite 3D images, rich with detailed information on the inner workings of cells.
Collapse
Affiliation(s)
- Myan Do
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, United States; National Center for X-ray Tomography, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States; Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States
| | - Samuel A Isaacson
- Department of Mathematics and Statistics, Boston University, Boston, MA 02215, United States
| | - Gerry McDermott
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, United States; National Center for X-ray Tomography, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States; Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States
| | - Mark A Le Gros
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, United States; National Center for X-ray Tomography, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States; Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States
| | - Carolyn A Larabell
- Department of Anatomy, University of California San Francisco, San Francisco, CA 94143, United States; National Center for X-ray Tomography, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States; Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, United States.
| |
Collapse
|
13
|
Selin M, Fogelqvist E, Werner S, Hertz HM. Tomographic reconstruction in soft x-ray microscopy using focus-stack back-projection. OPTICS LETTERS 2015; 40:2201-2204. [PMID: 26393699 DOI: 10.1364/ol.40.002201] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Tomographic reconstruction in soft x-ray microscopy is a powerful technique for obtaining high-resolution 3D images of biological samples. However, the depth of focus of such zone-plate-based microscopes is typically shorter than the thickness of many relevant biological objects, challenging the validity of the projection assumption used in conventional reconstruction algorithms. In order to make full use of the soft x-ray microscopes' high resolution, the tomographic reconstruction needs to take the depth of focus into account. Here we present a method to achieve high resolution in the full sample when the depth of focus is short compared to the sample thickness. The method relies on the back-projection of focus-stacked image data from x-ray microscopy. We demonstrate the method on theoretical and experimental data.
Collapse
|
14
|
Selin M, Fogelqvist E, Holmberg A, Guttmann P, Vogt U, Hertz HM. 3D simulation of the image formation in soft x-ray microscopes. OPTICS EXPRESS 2014; 22:30756-30768. [PMID: 25607024 DOI: 10.1364/oe.22.030756] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In water-window soft x-ray microscopy the studied object is typically larger than the depth of focus and the sample illumination is often partially coherent. This blurs out-of-focus features and may introduce considerable fringing. Understanding the influence of these phenomena on the image formation is therefore important when interpreting experimental data. Here we present a wave-propagation model operating in 3D for simulating the image formation of thick objects in partially coherent soft x-ray microscopes. The model is compared with present simulation methods as well as with experiments. The results show that our model predicts the image formation of transmission soft x-ray microscopes more accurately than previous models.
Collapse
|
15
|
Hagen C, Werner S, Carregal-Romero S, N Malhas A, G Klupp B, Guttmann P, Rehbein S, Henzler K, C Mettenleiter T, J Vaux D, J Parak W, Schneider G, Grünewald K. Multimodal nanoparticles as alignment and correlation markers in fluorescence/soft X-ray cryo-microscopy/tomography of nucleoplasmic reticulum and apoptosis in mammalian cells. Ultramicroscopy 2014; 146:46-54. [PMID: 24973653 PMCID: PMC4181793 DOI: 10.1016/j.ultramic.2014.05.009] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2014] [Revised: 05/15/2014] [Accepted: 05/24/2014] [Indexed: 11/19/2022]
Abstract
Correlative fluorescence and soft X-ray cryo-microscopy/tomography on flat sample holders is perfectly suited to study the uncompromised physiological status of adherent cells at its best possible preservation by imaging after fast cryo-immobilization. To understand the mechanism by which herpesviruses induce nucleoplasmic reticulum, i.e. invaginations of the nuclear envelope, during their egress from the host cell nucleus, morphologically similar structures found in laminopathies and after chemical induction were investigated as a potentially more easily accessible model system. For example, anti-retroviral protease inhibitors like Saquinavir also induce invaginations of the nuclear membranes. With the help of newly designed multimodal nanoparticles as alignment and correlation markers, and by optimizing fluorescence cryo-microscopy data acquisition, an elaborate three-dimensional network of nucleoplasmic reticulum was demonstrated in nuclei of Saquinavir-treated rabbit kidney cells expressing a fluorescently labeled inner nuclear membrane protein. In part of the protease inhibitor-treated samples, nuclei exhibited dramatic ultrastructural changes indicative of programmed cell death/apoptosis. This unexpected observation highlights another unique feature of soft X-ray microscopy, i.e. high absorption contrast information not relying on labeled cellular components, at a 3D resolution of approximately 40 nm (half-pitch) and through a sample thickness of several micrometers. These properties make it a valuable part of the cell biology imaging toolbox to visualize the cellular ultrastructure in its completeness.
Collapse
Affiliation(s)
- Christoph Hagen
- Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Oxford OX3 7BN, UK.
| | - Stephan Werner
- Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Wilhelm-Conrad-Röntgen Campus, 12489 Berlin, Germany.
| | | | - Ashraf N Malhas
- Sir William Dunn School of Pathology, University of Oxford, Oxford OX1 3RE, UK.
| | - Barbara G Klupp
- Institute of Molecular Virology and Cell Biology, Friedrich-Loeffler-Institut, 17493 Greifswald-Insel Riems, Germany.
| | - Peter Guttmann
- Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Wilhelm-Conrad-Röntgen Campus, 12489 Berlin, Germany.
| | - Stefan Rehbein
- Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Wilhelm-Conrad-Röntgen Campus, 12489 Berlin, Germany.
| | - Katja Henzler
- Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Wilhelm-Conrad-Röntgen Campus, 12489 Berlin, Germany.
| | - Thomas C Mettenleiter
- Institute of Molecular Virology and Cell Biology, Friedrich-Loeffler-Institut, 17493 Greifswald-Insel Riems, Germany.
| | - David J Vaux
- Sir William Dunn School of Pathology, University of Oxford, Oxford OX1 3RE, UK.
| | - Wolfgang J Parak
- Fachbereich Physik, Philipps Universität Marburg, Marburg 35043, Germany.
| | - Gerd Schneider
- Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Wilhelm-Conrad-Röntgen Campus, 12489 Berlin, Germany.
| | - Kay Grünewald
- Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Oxford OX3 7BN, UK.
| |
Collapse
|
16
|
Cinquin BP, Do M, McDermott G, Walters AD, Myllys M, Smith EA, Cohen-Fix O, Le Gros MA, Larabell CA. Putting molecules in their place. J Cell Biochem 2014; 115:209-16. [PMID: 23966233 DOI: 10.1002/jcb.24658] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2013] [Accepted: 08/14/2013] [Indexed: 12/18/2022]
Abstract
Each class of microscope is limited to imaging specific aspects of cell structure and/or molecular organization. However, imaging the specimen by complementary microscopes and correlating the data can overcome this limitation. Whilst not a new approach, the field of correlative imaging is currently benefitting from the emergence of new microscope techniques. Here we describe the correlation of cryogenic fluorescence tomography (CFT) with soft X-ray tomography (SXT). This amalgamation of techniques integrates 3D molecular localization data (CFT) with a high-resolution, 3D cell reconstruction of the cell (SXT). Cells are imaged in both modalities in a near-native, cryopreserved state. Here we describe the current state of the art in correlative CFT-SXT, and discuss the future outlook for this method.
Collapse
Affiliation(s)
- Bertrand P Cinquin
- Department of Anatomy, University of California San Francisco, San Francisco, California
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Dent KC, Hagen C, Grünewald K. Critical step-by-step approaches toward correlative fluorescence/soft X-ray cryo-microscopy of adherent mammalian cells. Methods Cell Biol 2014; 124:179-216. [PMID: 25287842 DOI: 10.1016/b978-0-12-801075-4.00009-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Soft X-ray cryo-microscopy/tomography with its extraordinary capability to map vitreous cells with high absorption contrast in their full three-dimensional extent, and at a resolution exceeding super-resolution fluorescence microscopy, is a valuable tool for integrative structural cell biology. Focusing on cell biological applications, its ongoing methodological development gained momentum by combining it with fluorescence cryo-microscopy, thus correlating highly resolved structural and specific information in situ. In this chapter, we provide a basic description of the techniques, as well as an overview of equipment and methods available to carry out correlative soft X-ray cryo-tomography experiments on frozen-hydrated cells grown on a planar support. Our aim here is to suggest ways that biologically representative data can be recorded to the highest possible resolution, while also keeping in mind the limitations of the technique during data acquisition and analysis. We have written from our perspective as electron cryo-microscopists/structural cell biologists who have experience using correlative fluorescence/cryoXM/T at synchrotron beamlines presently available for external users in Europe (HZB TXM at U41-FSGM, BESSY II, Berlin/Germany; Carl Zeiss TXMs at MISTRAL, ALBA, Barcelona/Spain, and B24, DLS, Oxfordshire, UK).
Collapse
Affiliation(s)
- Kyle C Dent
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom; Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Oxford, United Kingdom
| | - Christoph Hagen
- Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Oxford, United Kingdom
| | - Kay Grünewald
- Oxford Particle Imaging Centre, Division of Structural Biology, Wellcome Trust Centre for Human Genetics, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
18
|
Smith EA, Cinquin BP, Do M, McDermott G, Le Gros MA, Larabell CA. Correlative cryogenic tomography of cells using light and soft x-rays. Ultramicroscopy 2013; 143:33-40. [PMID: 24355261 DOI: 10.1016/j.ultramic.2013.10.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/10/2013] [Accepted: 10/18/2013] [Indexed: 10/26/2022]
Abstract
Correlated imaging is the process of imaging a specimen with two complementary modalities, and then combining the two data sets to create a highly informative, composite view. A recent implementation of this concept has been the combination of soft x-ray tomography (SXT) with fluorescence cryogenic microscopy (FCM). SXT-FCM is used to visualize cells that are held in a near-native, cryopreserved. The resultant images are, therefore, highly representative of both the cellular architecture and molecular organization in vivo. SXT quantitatively visualizes the cell and sub-cellular structures; FCM images the spatial distribution of fluorescently labeled molecules. Here, we review the characteristics of SXT-FCM, and briefly discuss how this method compares with existing correlative imaging techniques. We also describe how the incorporation of a cryo-rotation stage into a cryogenic fluorescence microscope allows acquisition of fluorescence cryogenic tomography (FCT) data. FCT is optimally suited for correlation with SXT, since both techniques image the specimen in 3-D, potentially with similar, isotropic spatial resolution.
Collapse
Affiliation(s)
- Elizabeth A Smith
- Department of Anatomy, School of Medicine, University of California San Francisco, San Francisco, CA, United States; National Center for X-ray Tomography, Advanced Light Source, Berkeley, CA, United States
| | - Bertrand P Cinquin
- Department of Anatomy, School of Medicine, University of California San Francisco, San Francisco, CA, United States; National Center for X-ray Tomography, Advanced Light Source, Berkeley, CA, United States
| | - Myan Do
- Department of Anatomy, School of Medicine, University of California San Francisco, San Francisco, CA, United States; National Center for X-ray Tomography, Advanced Light Source, Berkeley, CA, United States
| | - Gerry McDermott
- Department of Anatomy, School of Medicine, University of California San Francisco, San Francisco, CA, United States; National Center for X-ray Tomography, Advanced Light Source, Berkeley, CA, United States
| | - Mark A Le Gros
- Department of Anatomy, School of Medicine, University of California San Francisco, San Francisco, CA, United States; Physical BioSciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States; National Center for X-ray Tomography, Advanced Light Source, Berkeley, CA, United States.
| | - Carolyn A Larabell
- Department of Anatomy, School of Medicine, University of California San Francisco, San Francisco, CA, United States; Physical BioSciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, United States; National Center for X-ray Tomography, Advanced Light Source, Berkeley, CA, United States.
| |
Collapse
|
19
|
Carlson DB, Gelb J, Palshin V, Evans JE. Laboratory-based cryogenic soft x-ray tomography with correlative cryo-light and electron microscopy. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2013; 19:22-9. [PMID: 23332214 DOI: 10.1017/s1431927612013827] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Here we present a novel laboratory-based cryogenic soft X-ray microscope for whole cell tomography of frozen hydrated samples. We demonstrate the capabilities of this compact cryogenic microscope by visualizing internal subcellular structures of Saccharomyces cerevisiae cells. The microscope is shown to achieve better than 50 nm half-pitch spatial resolution with a Siemens star test sample. For whole biological cells, the microscope can image specimens up to 5 μm thick. Structures as small as 90 nm can be detected in tomographic reconstructions following a low cumulative radiation dose of only 7.2 MGy. Furthermore, the design of the specimen chamber utilizes a standard sample support that permits multimodal correlative imaging of the exact same unstained yeast cell via cryo-fluorescence light microscopy, cryo-soft X-ray microscopy, and cryo-transmission electron microscopy. This completely laboratory-based cryogenic soft X-ray microscope will enable greater access to three-dimensional ultrastructure determination of biological whole cells without chemical fixation or physical sectioning.
Collapse
Affiliation(s)
- David B Carlson
- Department of Molecular and Cellular Biology, University of California Davis, 1 Shields Avenue, Davis, CA 95616, USA
| | | | | | | |
Collapse
|
20
|
Harilal SS, Miloshevsky GV, Sizyuk T, Hassanein A. Effects of excitation laser wavelength on Ly-α and He-α line emission from nitrogen plasmas. PHYSICS OF PLASMAS 2013; 20:13105. [PMID: 23405037 PMCID: PMC3555915 DOI: 10.1063/1.4775725] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Accepted: 12/27/2012] [Indexed: 05/12/2023]
Abstract
Laser-produced nitrogen plasmas emitting radiation at 2.48 nm (Ly-α) and 2.88 nm (He-α) are considered potential efficient sources for water-window (WW) microscopy. The atomic and optical properties of nitrogen plasma and influence of the laser wavelength on the line emission in the WW range are investigated. It is found that the optimal temperatures for maximum emission from Ly-α and He-α spectral lines are 40-60 eV and 80-100 eV, respectively. The WW line emission and the conversion efficiency (CE) are estimated for three distinct Nd:YAG laser wavelengths (1064 nm, 532 nm, and 266 nm). The calculated CEs are compared with experimentally observed CE values. It is found that 1064 nm wavelength provides the highest CE from laser to Ly-α and He-α radiation.
Collapse
Affiliation(s)
- S S Harilal
- Center for Materials Under Extreme Environment, School of Nuclear Engineering, Purdue University, West Lafayette, Indiana 47907, USA
| | | | | | | |
Collapse
|
21
|
Loch RA, Sobierajski R, Louis E, Bosgra J, Bijkerk F. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources. OPTICS EXPRESS 2012; 20:28200-28215. [PMID: 23263054 DOI: 10.1364/oe.20.028200] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly used multilayer optics and propose new material combinations selected for a high damage threshold. Our study demonstrates that the damage thresholds of multilayer optics can vary over a large range of incidence fluences and can be as high as several hundreds of mJ/cm(2). This strongly suggests that multilayer mirrors are serious candidates for damage resistant optics. Especially, multilayer optics based on Li(2)O spacers are very promising for use in current and future short-wavelength radiation sources.
Collapse
Affiliation(s)
- R A Loch
- FOM-Institute DIFFER – Dutch Institute for Fundamental Energy Research, P.O. Box 1207, 3430 BE Nieuwegein, The Netherlands.
| | | | | | | | | |
Collapse
|
22
|
Martz DH, Selin M, von Hofsten O, Fogelqvist E, Holmberg A, Vogt U, Legall H, Blobel G, Seim C, Stiel H, Hertz HM. High average brightness water window source for short-exposure cryomicroscopy. OPTICS LETTERS 2012; 37:4425-7. [PMID: 23114317 DOI: 10.1364/ol.37.004425] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Laboratory water window cryomicroscopy has recently demonstrated similar image quality as synchrotron-based microscopy but still with much longer exposure times, prohibiting the spread to a wider scientific community. Here we demonstrate high-resolution laboratory water window imaging of cryofrozen cells with 10 s range exposure times. The major improvement is the operation of a λ=2.48 nm, 2 kHz liquid nitrogen jet laser plasma source with high spatial and temporal stability at high average brightness >1.5×10(12) ph/(s×sr×μm(2)×line), i.e., close to that of early synchrotrons. Thus, this source enables not only biological x-ray microscopy in the home laboratory but potentially other applications previously only accessible at synchrotron facilities.
Collapse
Affiliation(s)
- D H Martz
- Biomedical and X-Ray Physics, Department of Applied Physics, KTH Royal Institute of Technology/Albanova, Stockholm, Sweden
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Yuan Q, Zhang K, Hong Y, Huang W, Gao K, Wang Z, Zhu P, Gelb J, Tkachuk A, Hornberger B, Feser M, Yun W, Wu Z. A 30 nm-resolution hard X-ray microscope with X-ray fluorescence mapping capability at BSRF. JOURNAL OF SYNCHROTRON RADIATION 2012; 19:1021-8. [PMID: 23093765 DOI: 10.1107/s0909049512032852] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Accepted: 07/19/2012] [Indexed: 05/22/2023]
Abstract
A full-field transmission X-ray microscope (TXM) operating continuously from 5 keV to 12 keV with fluorescence mapping capability has been designed and constructed at the Beijing Synchrotron Radiation Facility, a first-generation synchrotron radiation facility operating at 2.5 GeV. Spatial resolution better than 30 nm has been demonstrated using a Siemens star pattern in both absorption mode and Zernike phase-contrast mode. A scanning-probe mode fluorescence mapping capability integrated with the TXM has been shown to provide 50 p.p.m. sensitivity for trace elements with a spatial resolution (limited by probing beam spot size) of 20 µm. The optics design, testing of spatial resolution and fluorescence sensitivity are presented here, including performance measurement results.
Collapse
Affiliation(s)
- Qingxi Yuan
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, People's Republic of China
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Legall H, Blobel G, Stiel H, Sandner W, Seim C, Takman P, Martz DH, Selin M, Vogt U, Hertz HM, Esser D, Sipma H, Luttmann J, Höfer M, Hoffmann HD, Yulin S, Feigl T, Rehbein S, Guttmann P, Schneider G, Wiesemann U, Wirtz M, Diete W. Compact x-ray microscope for the water window based on a high brightness laser plasma source. OPTICS EXPRESS 2012; 20:18362-9. [PMID: 23038387 DOI: 10.1364/oe.20.018362] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
We present a laser plasma based x-ray microscope for the water window employing a high-average power laser system for plasma generation. At 90 W laser power a brightness of 7.4 x 10(11) photons/(s x sr x μm(2)) was measured for the nitrogen Lyα line emission at 2.478 nm. Using a multilayer condenser mirror with 0.3 % reflectivity 10(6) photons/(μm(2) x s) were obtained in the object plane. Microscopy performed at a laser power of 60 W resolves 40 nm lines with an exposure time of 60 s. The exposure time can be further reduced to 20 s by the use of new multilayer condenser optics and operating the laser at its full power of 130 W.
Collapse
Affiliation(s)
- H Legall
- Max-Born-Institut, Max-Born-Str. 2A, D-12489 Berlin, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|