1
|
Agyeman K, Minaie A, Dodds SD. Does the polarity of radial head arthroplasty affect functional outcomes? A systematic review and meta-analysis. Clin Shoulder Elb 2024; 27:141-148. [PMID: 38738328 PMCID: PMC11181073 DOI: 10.5397/cise.2023.01088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Revised: 01/08/2024] [Accepted: 01/24/2024] [Indexed: 05/14/2024] Open
Abstract
BACKGROUND Radial head arthroplasty allows a high degree of customizability, and implant polarity has emerged as an important variable. The purpose of this meta-analysis was to evaluate differences in functional and clinical outcomes between patients receiving monopolar and bipolar radial head prosthetic implants. METHODS A systematic review and meta-analysis were employed, and 65 articles were identified in three databases. Twelve articles contained non-English or insufficient text and were consequently excluded, and 20 others did not contain sufficient data or follow-up. The remaining 33 articles were qualitatively and quantitatively reviewed. RESULTS In total, 33 populations were identified, with 809 unduplicated patients: 565 with monopolar and 244 with bipolar implants. In these respective patients, the mean follow-up was 40.2 and 56.9 months. Average Mayo Elbow Performance Score were 86.7 and 87.4 (P=0.80), respectively; average Disability of the Arm, Shoulder, and Hand scores were 17.9 and 14.7 (P=0.47), and average final flexion/extension arcs were 119.4° and 118.7° (P=0.48). Revision rates were 4.07% and 6.56%, while complication rates were 19.65% and 20.08% in the respective monopolar and bipolar patients. These increased relative risks associated with bipolar implants were not significant. CONCLUSIONS Radial head implant polarity does not appear to affect functional outcomes. While bipolar prosthetic design may increase the risks of revision and complications, the increases were not significant. Level of evidence: IV.
Collapse
Affiliation(s)
- Kofi Agyeman
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Arya Minaie
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Seth D. Dodds
- Department of Orthopaedics, University of Miami, Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
2
|
Vannabouathong C, Venugopal N, Athwal GS, Moro J, Bhandari M. Radial head arthroplasty: fixed-stem implants are not all equal-a systematic review and meta-analysis. JSES Int 2020; 4:30-38. [PMID: 32195463 PMCID: PMC7075758 DOI: 10.1016/j.jseint.2019.11.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Background Numerous fixed-stem implants exist for radial head arthroplasty; therefore, we conducted a systematic review to compare the safety and efficacy of different types of fixed-stem implants. Methods We conducted a literature search, updated from a previous systematic review, to identify studies evaluating a fixed-stem radial head arthroplasty implant for any indication. We extracted data on revision rates, specific complications, and functional scores. We pooled results across studies using a random-effects method, using proportions for dichotomous data and mean values for functional scores. We analyzed outcomes by indication and specific implant. Results We included 31 studies. Studies included patients with radial head fractures only, terrible-triad injuries, or Essex-Lopresti injuries or included a heterogeneous population. We identified 15 different fixed-stem implants. The results of our analysis revealed that patients with terrible-triad injuries may be at an increased risk of revision and instability and patients with Essex-Lopresti injuries may be at an increased risk of arthritis, capitellar erosion, and osteolysis. After removing these outliers and pooling the results by specific device, we observed variability across devices in the rates of revision, arthritis, capitellar erosion, instability, and osteolysis, as well as in functional scores. Conclusion Differences were seen across different implants in revision rates, certain complications, and functional scores. This study highlighted that these devices should be evaluated within the context of the patient population under examination, as patients with Essex-Lopresti or terrible-triad injuries may demonstrate worse outcomes relative to those with a fracture only.
Collapse
Affiliation(s)
| | | | - George S Athwal
- Department of Surgery, Western University, London, ON, Canada
| | - Jaydeep Moro
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Mohit Bhandari
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
3
|
Chen H, Wang Z, Shang Y. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis. J INVEST SURG 2018; 31:178-184. [PMID: 28901795 DOI: 10.1080/08941939.2017.1299262] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. MATERIALS AND METHODS Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. RESULTS The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values <0.001 for both unipolar and bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). CONCLUSION Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.
Collapse
Affiliation(s)
- Hongwei Chen
- a Department of Orthopedics , Wenzhou Medical College-Affiliated Yiwu Central Hospital , Yiwu, Zhejiang , China
| | - Ziyang Wang
- a Department of Orthopedics , Wenzhou Medical College-Affiliated Yiwu Central Hospital , Yiwu, Zhejiang , China
| | - Yongjun Shang
- b Department of Orthopedics , Dalian University Affiliated Xinhua Hospital , Dalian , Liaoning , China
| |
Collapse
|
4
|
Kachooei AR, Baradaran A, Ebrahimzadeh MH, van Dijk CN, Chen N. The Rate of Radial Head Prosthesis Removal or Revision: A Systematic Review and Meta-Analysis. J Hand Surg Am 2018; 43:39-53.e1. [PMID: 29054353 DOI: 10.1016/j.jhsa.2017.08.031] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Revised: 08/25/2017] [Accepted: 08/30/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE We conducted a meta-analysis and systematic review with the primary objective to determine the overall incidence of radial head prosthesis removal or revision. Our secondary objectives addressed the incidence of removal or revision based on the type of prosthesis fixation (cemented, uncemented smooth stem, uncemented press-fit), material (metal, Vitallium, titanium, pyrocarbon), and design (short vs long stem and monopolar vs bipolar), and the reasons for prosthetic removal or revision. METHODS We included 30 studies with a total of 1,017 patients out of whom 77 prostheses were removed and 45 prostheses were revised. RESULTS The pooled rate of radial head prosthesis removal or revision was 10.0% (95% confidence interval, 7.3%-13.6%) with a mean follow-up of 38 months. Subgroup analysis showed that the incidence of removal/revision was lowest with the cemented fixation, longer-stem, Vitallium material, and bipolar prosthesis. More than half of the prostheses were removed/revised for excision of the heterotopic ossification (47%) and for the treatment of stiffness and limitation of motion (42%). Other reasons recorded were pain (19%), loosening (16%), overstuffing (13%), instability (12%), infection (8%), and prosthesis disassembly (4%). CONCLUSIONS The current data show that the highest incidence of removal/revision occurred within 2 years after implantation. There was no major difference in the incidence of removal/revision among different designs and materials. Implant removal was often performed as part of a procedure to manage elbow stiffness and heterotopic ossification at the surgeon's preference, not necessarily because the implant was malfunctioning. It appears that most radial head arthroplasties have an acceptable and comparable mid-term longevity; however, it is unclear whether long-term longevity will differ between devices. TYPE OF STUDY/LEVEL OF EVIDENCE Prognostic II.
Collapse
Affiliation(s)
- Amir R Kachooei
- Orthopedic Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
| | - Aslan Baradaran
- Orthopedic Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - C Niek van Dijk
- Department of Orthopaedic Surgery, Academic Medical Center Amsterdam, Amsterdam, The Netherlands
| | - Neal Chen
- Hand and Upper Extremity Service, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
5
|
Laumonerie P, Reina N, Kerezoudis P, Declaux S, Tibbo ME, Bonnevialle N, Mansat P. The minimum follow-up required for radial head arthroplasty: a meta-analysis. Bone Joint J 2017; 99-B:1561-1570. [PMID: 29212677 DOI: 10.1302/0301-620x.99b12.bjj-2017-0543.r2] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Accepted: 08/11/2017] [Indexed: 11/05/2022]
Abstract
AIMS The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation. MATERIALS AND METHODS Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up. RESULTS A total of 40 studies were analysed: three were Group I and included 80 implants and 37 were Group II and included 1192 implants. In Group I, the mean time to re-operation was 1.37 years (0 to 11.25), the standard minimum follow-up was 3.25 years; painful loosening was the main indication for re-operation. In Group II, 33 Group II articles (89.2%) reported a minimum follow-up of < 3.25 years. CONCLUSION The literature does not provide a reliable estimate of the rate of re-operation after RHA. The reproducibility of results would be improved by using a minimum follow-up of three years combined with a consensus of the definition of the reasons for failure after RHA. Cite this article: Bone Joint J 2017;99-B:1561-70.
Collapse
Affiliation(s)
- P Laumonerie
- Institut Locomoteur, Hôpital Pierre-Paul Riquet, Place du Dr Baylac, TSA 40 031, Toulouse 31059, France
| | - N Reina
- Institut Locomoteur, Hôpital Pierre-Paul Riquet, Place du Dr Baylac, TSA 40 031, Toulouse 31059, France
| | - P Kerezoudis
- Mayo Clinic, 1216 2nd Street SW, Rochester, Minnesota 55905, USA
| | - S Declaux
- Institut Locomoteur, Hôpital Pierre-Paul Riquet, Place du Dr Baylac, TSA 40 031, Toulouse 31059, France
| | - M E Tibbo
- Mayo Clinic, 1216 2nd Street SW, Rochester, Minnesota 55905, USA
| | - N Bonnevialle
- Institut Locomoteur, Hôpital Pierre-Paul Riquet, Place du Dr Baylac, TSA 40 031, Toulouse 31059, France
| | - P Mansat
- Institut Locomoteur, Hôpital Pierre-Paul Riquet, Place du Dr Baylac, TSA 40 031, Toulouse 31059, France
| |
Collapse
|
6
|
Hackl M, Wegmann K, Koslowsky TC, Zeifang F, Schoierer O, Müller LP. Rare implant-specific complications of the MoPyC radial head prosthesis. J Shoulder Elbow Surg 2017; 26:830-837. [PMID: 28131684 DOI: 10.1016/j.jse.2016.11.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 11/06/2016] [Accepted: 11/11/2016] [Indexed: 02/01/2023]
Abstract
BACKGROUND According to currently available data, the clinical short-term results of the MoPyC radial head prosthesis (Bioprofile, Tornier, Montbonnot-Saint-Martin, France) seem favorable. However, we have encountered several implant-specific complications in recent years. Hence, this case series reports rare complications after radial head arthroplasty with the MoPyC prosthesis to make surgeons aware of their existence and to provide information about the underlying cause and possible salvage strategies. METHODS A retrospective chart review from 2011 to 2016 was conducted to identify all adult patients with a minimum 2-year follow-up who underwent or were referred after radial head arthroplasty with the MoPyC radial head prosthesis and experienced implant-related complications. RESULTS Five patients with 7 implant-related complications were found. One patient experienced breakage of the pyrocarbon head. In another patient, breakage of the stem and-after revision surgery-partial breakage were observed. Disassembly of the prosthesis was seen in 1 case. Extensive periprosthetic stress shielding was seen in 3 patients resulting in symptomatic loosening (1), periprosthetic radial neck fracture (1), and stem migration (1). CONCLUSIONS Whereas clinical short-term results of the MoPyC radial head prosthesis are satisfactory, rare implant-related complications can occur. Surgeons should be aware of these complications as they may lead to a poor outcome.
Collapse
Affiliation(s)
- Michael Hackl
- Center for Orthopedic and Trauma Surgery, Uniklinik Köln, Köln, Germany; Köln Center for Musculoskeletal Biomechanics, Medical Faculty, University of Köln, Köln, Germany.
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, Uniklinik Köln, Köln, Germany; Köln Center for Musculoskeletal Biomechanics, Medical Faculty, University of Köln, Köln, Germany
| | | | - Felix Zeifang
- Center for Orthopedic and Trauma Surgery, University Medical Center, Heidelberg, Germany
| | - Oliver Schoierer
- Center for Orthopedic and Trauma Surgery, University Medical Center, Heidelberg, Germany
| | - Lars P Müller
- Center for Orthopedic and Trauma Surgery, Uniklinik Köln, Köln, Germany; Köln Center for Musculoskeletal Biomechanics, Medical Faculty, University of Köln, Köln, Germany
| |
Collapse
|
7
|
Bowman SH, Barfield WR, Slone HS, Shealy GJ, Walton ZJ. The clinical implications of heterotopic ossification in patients treated with radial head replacement for trauma: A case series and review of the literature. J Orthop 2016; 13:272-7. [PMID: 27408502 DOI: 10.1016/j.jor.2016.06.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 05/11/2016] [Accepted: 06/08/2016] [Indexed: 11/28/2022] Open
Abstract
Radial head arthroplasty (RHA) is an acceptable treatment for comminuted radial head fractures (RHF). Fourteen patients with no postop HO prophylaxis were treated with RHA for comminuted RHF. A 50% incidence in HO was seen following RHA with a statistically increased risk (p ≤ 0.05) of reoperation compared to those without HO. Decreased ROM was seen on the affected side (p ≤ 0.05); patients without HO showed no statistical difference (p ≥ 0.05) in ROM or grip strength. HO following RHA increases patient risk for reoperation and decreases ROM. We recommend HO prophylaxis with NSAIDs and/or radiotherapy if no direct patient contraindications are found.
Collapse
Affiliation(s)
- Seth H Bowman
- Medical University of South Carolina, Charleston, SC, United States
| | | | - Harris S Slone
- Medical University of South Carolina, Charleston, SC, United States
| | - Gerald J Shealy
- Medical University of South Carolina, Charleston, SC, United States
| | - Zeke J Walton
- Medical University of South Carolina, Charleston, SC, United States
| |
Collapse
|
8
|
Levy JC, Formaini NT, Kurowicki J. Outcomes and radiographic findings of anatomic press-fit radial head arthroplasty. J Shoulder Elbow Surg 2016; 25:802-9. [PMID: 26897310 DOI: 10.1016/j.jse.2015.11.014] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2015] [Revised: 10/26/2015] [Accepted: 11/10/2015] [Indexed: 02/01/2023]
Abstract
BACKGROUND Radial head arthroplasty (RHA) is a popular method of treatment for complex fractures of the radial head. The purpose of this study was to investigate patient outcomes and radiographic findings associated with a single anatomic monopolar press-fit radial head system commonly used for the treatment of radial head fractures. METHODS A retrospective review of prospectively collected data was performed for a consecutive series of patients treated with a press-fit anatomically designed RHA between November 2007 and April 2014. The most recent radiographs were evaluated for loosening, stress shielding, and instability. Postoperative motion and outcomes were reported at most recent follow-up. RESULTS At an average follow-up of 30 months, 6 of the 15 patients (40%) demonstrated radiographic loosening. Six of the 9 patients (67%) without loosening demonstrated stress shielding (average, 6 mm). Functional outcome scores included a mean American Shoulder and Elbow Surgeons score of 70, Mayo Elbow Performance Score of 85, visual analog scale score for pain of 2, visual analog scale score for function of 7, and Single Assessment Numeric Evaluation score of 75. Average flexion-extension arc was 14° to 138°, and average pronation-supination was 75° to 74°. All 6 of the patients with radiographic loosening had undergone RHA with an associated ligamentous injury repair. Satisfaction among patients was high as no patient reported an unsatisfactory outcome. CONCLUSIONS The use of an anatomic, press-fit monopolar RHA in the management of acute complex radial head fractures has yielded excellent clinical outcomes despite high rates of radiographic loosening and stress shielding. Press-fit RHA in the setting of ligamentous injury warrants further investigation because of a high rate of implant loosening observed.
Collapse
|
9
|
Fowler JR, Henry SE, Xu P, Goitz RJ. Outcomes Following Radial Head Arthroplasty. Orthopedics 2016; 39:153-60. [PMID: 27045484 DOI: 10.3928/01477447-20160324-06] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Accepted: 02/04/2015] [Indexed: 02/03/2023]
Abstract
Most current series of radial head arthroplasty include small numbers of patients with short- to medium-term follow-up and significant heterogeneity in patients, treatments, and outcome measures. The purpose of this systematic review was to review outcomes for radial head arthroplasty based on injury chronicity, injury pattern, and type of implant used. The authors systematically searched electronic databases for studies containing radial head arthroplasty or radial head replacement and identified 19 studies for inclusion in the analysis. For each included study, a composite mean was obtained for Mayo Elbow Performance Score (MEPS) and range of motion. Outcomes were said to differ significantly if their confidence intervals did not overlap. The MEPS for acute treatment (90) was higher than that for delayed treatment (81). There was no difference in the pooled MEPS between the isolated (89) and complex injury pattern (87) groups or implant material. There was no difference in range of motion between the acute and delayed or isolated and complex groups, but the average degree of pronation was higher in patients treated with titanium implants (76°) compared with cobalt chromium implants (66°). This systematic review suggests that outcomes are improved following acute arthroplasty for treatment of radial head fractures compared with delayed treatment, based on MEPS. The lack of other significant differences detected is likely due to the significant heterogeneity and inadequate power in current studies. Further prospective studies isolating the different variables will be needed to determine their true effect on outcomes. [Orthopedics. 2016; 39(3):153-160.].
Collapse
|
10
|
Die Passgenauigkeit monopolarer Radiuskopfprothesen im proximalen Radioulnargelenk. ACTA ACUST UNITED AC 2015. [DOI: 10.1007/s11678-015-0337-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Delclaux S, Lebon J, Faraud A, Toulemonde J, Bonnevialle N, Coulet B, Mansat P. Complications of radial head prostheses. INTERNATIONAL ORTHOPAEDICS 2015; 39:907-13. [PMID: 25655903 DOI: 10.1007/s00264-015-2689-7] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Accepted: 01/20/2015] [Indexed: 11/27/2022]
Abstract
Radial head prostheses are indicated for treatment of complex radial head fractures not amenable for fixation. After the initial experience with silastic implants, metallic or pyrocarbon arthroplasty have been used for 20 years. Little is known about complications related to these implants. Main complications are related to loosening whether they are cemented or not cemented. Hypotheses have been proposed like inadequate stem design, insufficient cement technique, stress shielding, and foreign body reactions secondary to polyethylene wear. Pain and stiffness are other common complications often related to oversized radial head component or overstuffing of the joint with excessive lengthening of the radius. Instability can be another complication in the context of more complex trauma with lateral collateral ligament complex lesion and coronoid fracture. Fixation of the coronoid fracture, reinsertion of the lateral collateral ligament complex, and the use of monobloc radial head prosthesis are recommended to stabilize the joint. Finally, osteoarthritis is common with follow-up.
Collapse
Affiliation(s)
- Stéphanie Delclaux
- Orthopaedic and Traumatology Department, University Hospital of Toulouse Riquet Hospital, CHU Purpan, Place du Dr Baylac, 31059, Toulouse, France
| | | | | | | | | | | | | |
Collapse
|
12
|
Allavena C, Delclaux S, Bonnevialle N, Rongières M, Bonnevialle P, Mansat P. Outcomes of bipolar radial head prosthesis to treat complex radial head fractures in 22 patients with a mean follow-up of 50 months. Orthop Traumatol Surg Res 2014; 100:703-9. [PMID: 25281556 DOI: 10.1016/j.otsr.2014.06.019] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2013] [Revised: 04/20/2014] [Accepted: 06/24/2014] [Indexed: 02/02/2023]
Abstract
BACKGROUND Radial head replacement is indicated to treat complex proximal radial fractures that are not amenable to internal fixation. HYPOTHESIS Implantation of a bipolar radial head prosthesis after radial head excision ensures stability of the elbow and forearm, thereby promoting ligament healing and restoring elbow function. MATERIAL AND METHODS Twenty-two patients managed with implantation of a bipolar radial head prosthesis (Guepar(®)) were evaluated after a mean follow-up of 50 months. The procedure was performed in the acute setting in 16 patients, including 13 with associated injuries; and at the stage of sequelae in 6 patients. RESULTS Prosthesis removal was required in 4 patients. Of the remaining 18 patients, 14 (77%) had satisfactory Mayo Elbow Performance Score values, 14 (77%) little or no functional impairment, and 11 (61%) little or no pain. Mean motion arcs were 100° in flexion-extension and 143° in pronation-supination. Mean elbow strength in flexion and mean wrist strength were 67% and 86%, respectively, of those on the contralateral normal side. Radio-lucent lines were visible around the prosthesis in 5 patients, radial neck osteolysis in 10 patients, and capitellar erosion in 7 patients. Seven patients each experienced a complication. Early revision surgery to treat elbow instability was required in 6 patients. DISCUSSION Outcomes after Guepar(®) bipolar radial head prosthesis implantation were disappointing in patients with complex radial head fractures seen in the acute or chronic setting. The associated injuries to bones and ligaments and the measures taken to repair them influence the prognosis. The complication rate is non-negligible and seems to increase over time. LEVEL OF EVIDENCE IV, retrospective study.
Collapse
Affiliation(s)
- C Allavena
- Service de chirurgie orthopédique-traumatologie, hôpital Purpan, place du Dr-Baylac, 31059 Toulouse cedex, France
| | - S Delclaux
- Service de chirurgie orthopédique-traumatologie, hôpital Purpan, place du Dr-Baylac, 31059 Toulouse cedex, France
| | - N Bonnevialle
- Service de chirurgie orthopédique-traumatologie, hôpital Purpan, place du Dr-Baylac, 31059 Toulouse cedex, France
| | - M Rongières
- Service de chirurgie orthopédique-traumatologie, hôpital Purpan, place du Dr-Baylac, 31059 Toulouse cedex, France
| | - P Bonnevialle
- Service de chirurgie orthopédique-traumatologie, hôpital Purpan, place du Dr-Baylac, 31059 Toulouse cedex, France
| | - P Mansat
- Service de chirurgie orthopédique-traumatologie, hôpital Purpan, place du Dr-Baylac, 31059 Toulouse cedex, France.
| |
Collapse
|
13
|
|
14
|
Kaur MN, MacDermid JC, Grewal RR, Stratford PW, Woodhouse LJ. Functional outcomes post-radial head arthroplasty: a systematic review of literature. Shoulder Elbow 2014; 6:108-18. [PMID: 27582924 PMCID: PMC4935071 DOI: 10.1177/1758573214524934] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2013] [Accepted: 01/31/2014] [Indexed: 12/14/2022]
Abstract
BACKGROUND The present study was conducted to determine the quality and content of research on the functional outcomes and complications post-metal radial head arthroplasty (RHAP). METHODS A comprehensive search of medical databases for studies reporting on functional outcomes of patients undergoing metallic RHAP was conducted. The Structured Effectiveness Quality Evaluation Scale (SEQES) was used to evaluate quality of the studies. RESULTS We identified 21 Sackett's Level IV studies reporting on 391 radial heads. The mean duration of follow-up was 47.2 months and the mean (SD) age of patients was 48.4 years (6.9 years). The male to female ratio was found to be 1.05 : 1 and the dominant arm was involved in 54% of patients. When functional outcomes achieved post-RHAP were compared with normative scores, the comparison suggested that RHAP has good to excellent functional outcomes in short- to mid-term follow-up. The weighted mean (SD) Mayo Elbow Performance Score was 85.8 (4.1) (95% confidence interval 85.3 to 86.3). Incidences of implant removal (3.06%) and revision (2.22%) were found to be low. CONCLUSIONS There is consistent low-quality evidence of positive functional outcomes following RHAP. The heterogeneity of type of implant, patient characteristics and outcome measures used, along with an inadequate reporting of study details, restrict any definitive conclusions being made.
Collapse
Affiliation(s)
- Manraj Nirmal Kaur
- School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada,Surgical Outcomes Research Centre (SOURCE), Department of Surgery, McMaster University, Hamilton, ON, Canada,Manraj Kaur, 101-206 James S, Hamilton, Ontario, L8P 3A9 Canada. Tel.: 905-522-1155 ext. 35874. Fax: 905-523-0229. E-mail:
| | - Joy C MacDermid
- School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada,Hand and Upper Limb Centre, St. Joseph’s Health Centre, London, ON, Canada
| | - Ruby R Grewal
- Hand and Upper Limb Centre, St. Joseph’s Health Centre, London, ON, Canada,St Joseph’s Health Centre, University of Western Ontario, London, ON, Canada
| | - Paul W Stratford
- School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada
| | - Linda J Woodhouse
- Department of Physical Therapy, Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, Canada
| |
Collapse
|
15
|
Li N, Chen S. Open reduction and internal-fixation versus radial head replacement in treatment of Mason type III radial head fractures. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2013; 24:851-5. [DOI: 10.1007/s00590-013-1367-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2013] [Accepted: 11/08/2013] [Indexed: 10/26/2022]
|
16
|
Abstract
Radial head arthroplasty is the treatment of choice for non-reconstructble radial head fractures. Solid prostheses made of metal or pyocarbon can restore valgus stability of the elbow independent of design or stem fixation. Short-term and mid-term results show mostly good to excellent results without any evident differences between the different prosthesis philosophies. In order to obtain good results it is important to implant the prosthesis correctly without overfilling and to judge concomitant ligament injuries correctly. This article discusses the anatomical and biomechanical basis of radial head arthroplasty as well as the surgical technique and radiological diagnosis of overfilling.
Collapse
|
17
|
Berschback JC, Lynch TS, Kalainov DM, Wysocki RW, Merk BR, Cohen MS. Clinical and radiographic comparisons of two different radial head implant designs. J Shoulder Elbow Surg 2013; 22:1108-20. [PMID: 23659806 DOI: 10.1016/j.jse.2013.02.011] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2012] [Revised: 02/07/2013] [Accepted: 02/18/2013] [Indexed: 02/01/2023]
Abstract
BACKGROUND There is little comparative data to guide implant choice for radial head replacements. The purpose of this study was to evaluate the clinical and radiographic results between patients who received a smooth-stemmed bipolar radial head implant and patients who received an in-growth monopolar prosthesis. METHODS Twenty-seven patients requiring a metallic radial head implant in the management of acute or chronic elbow trauma were evaluated. Fourteen patients received a smooth-stemmed bipolar prosthesis and 13 patients received a press-fit monopolar prosthesis. Patients returned for follow-up at an average of 33 months (range, 18-57). Outcome assessments included joint motion, elbow stability, grip strength, pain, the Mayo Elbow Performance Index, and the Disability of Arm, Shoulder and Hand questionnaire. Radiographs were reviewed for joint congruence, ectopic bone, periprosthetic osteolysis, degenerative arthritis, and capitellar wear, and selected patients were tested for inflammatory markers and metal ion levels. RESULTS The differences between patient groups for elbow flexion and forearm pronation averaged 10° or less. There were no other pertinent differences between groups for standardized patient and examiner-determined outcomes. There was a trend for ectopic bone to develop more commonly around the smooth-stemmed implants, while periprosthetic osteolysis was more pronounced in cases with the press-fit design. Inflammatory markers were normal, and metal ion levels did not exceed values reported for a well-functioning hip arthroplasty. CONCLUSION Outcomes at short- to mid-term follow-up were similar with either implant design. Loosening of a press-fit prosthesis may lead to extensive osteolysis, but of undetermined clinical consequence.
Collapse
Affiliation(s)
- John C Berschback
- Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL 60612, USA
| | | | | | | | | | | |
Collapse
|
18
|
Fowler JR, Goitz RJ. Radial head fractures: indications and outcomes for radial head arthroplasty. Orthop Clin North Am 2013; 44:425-31, x. [PMID: 23827844 DOI: 10.1016/j.ocl.2013.03.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Radial head fractures without associated bony or ligamentous injury can be safely treated with internal fixation, if possible, or arthroplasty if nonreconstructable. However, nonreconstructable radial head fractures in association with elbow dislocation and/or ligamentous injury in the elbow or forearm represent a specific subset of injuries that requires restoration of the radiocapitellar articulation for optimal function. The purpose of this article was to summarize the indications for radial head arthroplasty and discuss the reported outcomes.
Collapse
Affiliation(s)
- John R Fowler
- Division of Hand, Upper Extremity, and Microvascular Surgery, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA 15213, USA.
| | | |
Collapse
|
19
|
Ricón FJ, Sánchez P, Lajara F, Galán A, Lozano JA, Guerado E. Result of a pyrocarbon prosthesis after comminuted and unreconstructable radial head fractures. J Shoulder Elbow Surg 2012; 21:82-91. [PMID: 21531150 DOI: 10.1016/j.jse.2011.01.032] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2010] [Revised: 10/18/2010] [Accepted: 01/16/2011] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study is to analyze the results of treating unreconstructable acute radial head fractures associated with other elbow fractures and soft-tissue injuries with a pyrocarbon radial head prosthesis replacement, as well as repair of the associated injuries. MATERIALS AND METHODS Twenty-eight patients with Mason type III unreconstructable and unstable radial head fractures and with associated injuries (according to Hotchkiss classification modified by van Riet) were treated with a pyrocarbon radial head prosthesis replacement; repair of collateral ligaments and associated elbow fractures was also carried out. Patients were evaluated in accordance with the Mayo Elbow Performance Score, measuring pain, grip strength, range of motion, and stability, as well as radiographic images. RESULTS After a mean of 32 months postoperatively (range, 12-62 months), the mean Mayo Elbow Performance Score was 92 points. The result was considered excellent or good in 25 patients, with a high degree of satisfaction and functional restoration. CONCLUSION The results of treating Mason type III radial head fractures with additional elbow fractures and soft-tissue injuries with pyrocarbon radial head prostheses are satisfactory; nevertheless, long-term follow-up is still necessary.
Collapse
Affiliation(s)
- F Javier Ricón
- Orthopaedic Surgery and Traumatology Service, Vega Baja Hospital, Orihuela, Alicante, Spain.
| | | | | | | | | | | |
Collapse
|
20
|
Charalambous CP, Stanley JK, Mills SP, Hayton MJ, Hearnden A, Trail I, Gagey O. Comminuted radial head fractures: aspects of current management. J Shoulder Elbow Surg 2011; 20:996-1007. [PMID: 21600788 DOI: 10.1016/j.jse.2011.02.013] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2010] [Revised: 02/06/2011] [Accepted: 02/11/2011] [Indexed: 02/01/2023]
|
21
|
van Riet RP, Morrey BF. Delayed valgus instability and proximal migration of the radius after radial head prosthesis failure. J Shoulder Elbow Surg 2010; 19:e7-10. [PMID: 20675155 DOI: 10.1016/j.jse.2010.04.046] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2009] [Revised: 04/20/2010] [Accepted: 04/25/2010] [Indexed: 02/01/2023]
|
22
|
Abstract
There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.
Collapse
Affiliation(s)
- R. P. van Riet
- Monica Hospital SPM Deurne, Stevenslei 20, 2100 Deurne, Belgium
| | - J. Sanchez-Sotelo
- Department of Orthopaedic Surgery, Mayo Clinic, Mayo Foundation, 200 First Street SW, Rochester, Minnesota 55905, USA
| | - B. F. Morrey
- Department of Orthopaedic Surgery, Mayo Clinic, Mayo Foundation, 200 First Street SW, Rochester, Minnesota 55905, USA
| |
Collapse
|