Jhun CS, Xu L, Siedlecki C, Bartoli CR, Yeager E, Lukic B, Scheib CM, Newswanger R, Cysyk JP, Shen C, Bohnenberger K, Weiss WJ, Rosenberg G. Kinetic and Dynamic Effects on Degradation of von Willebrand Factor. ASAIO J 2023; 69:467-474. [PMID: 36399789 PMCID: PMC10143388 DOI: 10.1097/mat.0000000000001848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
The loss of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in aortic stenosis (AS) and continuous-flow left ventricular assist devices (cf-LVADs) is believed to be associated with high turbulent blood shear. The objective of this study is to understand the degradation mechanism of HMWM in terms of exposure time (kinetic) and flow regime (dynamics) within clinically relevant pathophysiologic conditions. A custom high-shear rotary device capable of creating fully controlled exposure times and flows was used. The system was set so that human platelet-poor plasma flowed through at 1.75 ml/sec, 0.76 ml/sec, or 0.38 ml/sec resulting in the exposure time ( texp ) of 22, 50, or 100 ms, respectively. The flow was characterized by the Reynolds number (Re). The device was run under laminar (Re = 1,500), transitional (Re = 3,000; Re = 3,500), and turbulent (Re = 4,500) conditions at a given texp followed by multimer analysis. No degradation was observed at laminar flow at all given texp . Degradation of HMWM at a given texp increases with the Re. Re ( p < 0.0001) and texp ( p = 0.0034) are significant factors in the degradation of HMWM. Interaction between Re and texp , however, is not always significant ( p = 0.73).
Collapse
Affiliation(s)
- Choon-Sik Jhun
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Lichong Xu
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Christopher Siedlecki
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
- Department of Biomedical Engineering, College of Engineering, The Pennsylvania State University, University Park, Pennsylvania
| | - Carlo R. Bartoli
- Department of Cardiothoracic Surgery, Geisinger Medical Center, Danville, Pennsylvania
| | - Eric Yeager
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Branka Lukic
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Christopher M. Scheib
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Raymond Newswanger
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Joshua P. Cysyk
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Chan Shen
- Division of Outcomes Research and Quality, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - Karl Bohnenberger
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
| | - William J. Weiss
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
- Department of Biomedical Engineering, College of Engineering, The Pennsylvania State University, University Park, Pennsylvania
| | - Gerson Rosenberg
- From the Division of Applied Biomedical Engineering, Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
- Department of Biomedical Engineering, College of Engineering, The Pennsylvania State University, University Park, Pennsylvania
| |
Collapse
|
2
|
Li Y, Wang H, Xi Y, Sun A, Wang L, Deng X, Chen Z, Fan Y. A mathematical model for assessing shear induced bleeding risk. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 231:107390. [PMID: 36745955 DOI: 10.1016/j.cmpb.2023.107390] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 01/16/2023] [Accepted: 01/30/2023] [Indexed: 06/18/2023]
Abstract
PURPOSE The objective of this study is to develop a bleeding risk model for assessing device-induced bleeding risk in patients supported with blood contact medical devices (BCMDs). METHODS The mathematical model for evaluating bleeding risk considers the effects of shear stress on von Willebrand factor (vWF) unfolding, high molecular weight multimers-vWF (HMWM-vWF) degradation, platelet activation and receptor shedding and platelet-vWF binding ability. Functions of the effect of shear stress on the above factors are fitted/employed and solved by the Eulerian transport equation. An axial flow-through Couette device and two clinical VADs which are HeartWare Ventricular Assist Device (HVAD) and HeartMate II (HM II) blood pump were employed to perform the simulation to evaluate platelet receptor shedding (GPIbα and GPIIb/IIIa), loss of HWMW-vWF, platelet-vWF binding ability and bleeding risk for validating the accuracy of our model. RESULTS The platelet-vWF binding ability after being subjected to high shear region in the axial flow-through Couette device predicted by our bleeding model was highly consistent with reported experimental data. As indicated by our CFD simulation results in the axial flow-through Couette device, it can find that an increase in shear stress led to a decrease in the adhesion ability of platelets on vWF, while the binding ability of vWF with platelets first increase and then decrease as shear stress elevates gradually beyond a threshold. The factor of exposure time can enhance the effect of shear stress. Additionally, the shear-induced bleeding risk predicted by our model increases with increasing shear stress and exposure time in an axial flow-through Couette device. As indicated by our numerical model, the bleeding risk in HVAD was higher than HMII, which is highly consistent with the meta-analysis based on clinical statistics. Our simulation investigations in these two clinical VADs also found that HVAD caused a higher rate of platelet receptor shedding and lower damage to HWMW-vWF than HeartMate II. The high shear stress generated in the narrow and turbulent regions of both VADs was the underlying cause of device-induced bleeding. CONCLUSION In this study, the shear-induced bleeding risk predicted by our bleeding model in axial flow-through Couette device and two clinical VADs is consistent or highly correlated with experimental and clinical findings, which proves the accuracy of our bleeding model. Our bleeding model can be used to aid the development of new BCMDs with improved functional characteristics and biocompatibility, and help to reduce risk of device-induced adverse events in patients.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Lizhen Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China.
| |
Collapse
|
3
|
Analysis of the HeartWare HVAD pump characteristics under pulsatile operation. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
4
|
Shiraishi Y, Tachizaki Y, Inoue Y, Hayakawa M, Yamada A, Kayashima M, Matsumoto M, Horiuchi H, Yambe T. Hemolysis and von Willebrand factor degradation in mechanical shuttle shear flow tester. J Artif Organs 2021; 24:111-119. [PMID: 33559766 PMCID: PMC8154843 DOI: 10.1007/s10047-020-01219-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 04/15/2020] [Indexed: 12/02/2022]
Abstract
Chronic blood trauma caused by the shear stresses generated by mechanical circulatory support (MCS) systems is one of the major concerns to be considered during the development of ventricular assist devices. Large multimers with high-molecular-weight von Willebrand factor (VWF) are extended by the fluid forces in a shear flow and are cleaved by ADAMTS13. Since the mechanical revolving motions in artificial MCSs induce cleavage in large VWF multimers, nonsurgical bleeding associated with the MCS is likely to occur after mechanical hemodynamic support. In this study, the shear stress (~ 600 Pa) and exposure time related to hemolysis and VWF degradation were investigated using a newly designed mechanical shuttle shear flow tester. The device consisted of a pair of cylinders facing the test section of a small-sized pipe; both the cylinders were connected to composite mechanical heads with a sliding-sleeve structure for axial separation during the withdrawing motion. The influence of exposure time, in terms of the number of stress cycles, on hemolysis and VWF degradation was confirmed using fresh goat blood, and the differences in the rates of dissipation of the multimers were established. The plasma-free hemoglobin levels showed a logarithmic increase corresponding to the number of cycles, and the dissipation of large VWF multimers occurred within a few seconds under high shear stress flow conditions.
Collapse
Affiliation(s)
- Yasuyuki Shiraishi
- Department of Preclinical Evaluation, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan.
- Department of Medical Engineering and Cardiology, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan.
| | - Yuma Tachizaki
- Department of Medical Engineering and Cardiology, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Yusuke Inoue
- Department of Medical Engineering and Cardiology, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Masaki Hayakawa
- Department of Blood Transfusion Medicine, Nara Medical University, Nara, Japan
| | - Akihiro Yamada
- Department of Medical Engineering and Cardiology, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| | - Michinori Kayashima
- Department of Blood Transfusion Medicine, Nara Medical University, Nara, Japan
| | - Masanori Matsumoto
- Department of Blood Transfusion Medicine, Nara Medical University, Nara, Japan
| | - Hisanori Horiuchi
- Department of Molecular and Cellular Biology, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan
| | - Tomoyuki Yambe
- Department of Preclinical Evaluation, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan
- Department of Medical Engineering and Cardiology, Pre-Clinical Research Center, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryo-machi, Aoba-ku, Sendai, 980-8575, Japan
| |
Collapse
|
5
|
Köhne I. Kontinuierlich fördernde Blutpumpen für die Langzeitherzunterstützung. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2020. [DOI: 10.1007/s00398-020-00398-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
6
|
Ferrari A, Giampietro C, Bachmann B, Bernardi L, Bezuidenhhout D, Ermanni P, Hopf R, Kitz S, Kress G, Loosli C, Marina V, Meboldt M, Pellegrini G, Poulikakos D, Rebholz M, Schmid Daners M, Schmidt T, Starck C, Stefopoulos G, Sündermann S, Thamsen B, Zilla P, Potapov E, Falk V, Mazza E. A Novel Hybrid Membrane VAD as First Step Toward Hemocompatible Blood Propulsion. Ann Biomed Eng 2020; 49:716-731. [PMID: 32901382 PMCID: PMC7851026 DOI: 10.1007/s10439-020-02590-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 08/11/2020] [Indexed: 12/31/2022]
Abstract
Heart failure is a raising cause of mortality. Heart transplantation and ventricular assist device (VAD) support represent the only available lifelines for end stage disease. In the context of donor organ shortage, the future role of VAD as destination therapy is emerging. Yet, major drawbacks are connected to the long-term implantation of current devices. Poor VAD hemocompatibility exposes the patient to life-threatening events, including haemorrhagic syndromes and thrombosis. Here, we introduce a new concept of artificial support, the Hybrid Membrane VAD, as a first-of-its-kind pump prototype enabling physiological blood propulsion through the cyclic actuation of a hyperelastic membrane, enabling the protection from the thrombogenic interaction between blood and the implant materials. The centre of the luminal membrane surface displays a rationally-developed surface topography interfering with flow to support a living endothelium. The precast cell layer survives to a range of dynamically changing pump actuating conditions i.e., actuation frequency from 1 to 4 Hz, stroke volume from 12 to 30 mL, and support duration up to 313 min, which are tested both in vitro and in vivo, ensuring the full retention of tissue integrity and connectivity under challenging conditions. In summary, the presented results constitute a proof of principle for the Hybrid Membrane VAD concept and represent the basis for its future development towards clinical validation.
Collapse
Affiliation(s)
- Aldo Ferrari
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092, Zurich, Switzerland. .,EMPA, Swiss Federal Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600, Dübendorf, Switzerland. .,Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.
| | - Costanza Giampietro
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092, Zurich, Switzerland.,EMPA, Swiss Federal Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600, Dübendorf, Switzerland
| | - Björn Bachmann
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092, Zurich, Switzerland
| | - Laura Bernardi
- Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Deon Bezuidenhhout
- Christiaan Barnard Division of Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Paolo Ermanni
- Laboratory of Composite Materials and Adaptive Structures, ETH Zurich, 8092, Zurich, Switzerland
| | - Raoul Hopf
- EMPA, Swiss Federal Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600, Dübendorf, Switzerland.,Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Sarah Kitz
- Laboratory for Animal Model Pathology, Institute of Veterinary Pathology, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Gerald Kress
- Laboratory of Composite Materials and Adaptive Structures, ETH Zurich, 8092, Zurich, Switzerland
| | - Christian Loosli
- Laboratory of Composite Materials and Adaptive Structures, ETH Zurich, 8092, Zurich, Switzerland
| | - Vita Marina
- Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Mirko Meboldt
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Giovanni Pellegrini
- Laboratory for Animal Model Pathology, Institute of Veterinary Pathology, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Dimos Poulikakos
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092, Zurich, Switzerland
| | - Mathias Rebholz
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Marianne Schmid Daners
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Tanja Schmidt
- Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin, Berlin, Germany
| | - Christoph Starck
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany
| | - Georgios Stefopoulos
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092, Zurich, Switzerland
| | - Simon Sündermann
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany.,Department of Cardiovascular Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.,Deutsches Zentrum für Herz-Kreislaufforschung, Standort Berlin, Germany
| | - Bente Thamsen
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Peter Zilla
- Christiaan Barnard Division of Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa
| | - Evgenij Potapov
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany.,Department of Cardiovascular Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.,Deutsches Zentrum für Herz-Kreislaufforschung, Standort Berlin, Germany.,Translational Cardiovascular Technologies, Institute of Translational Medicine, Department of Health Sciences and Technology, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany. .,Department of Cardiovascular Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany. .,Deutsches Zentrum für Herz-Kreislaufforschung, Standort Berlin, Germany. .,Translational Cardiovascular Technologies, Institute of Translational Medicine, Department of Health Sciences and Technology, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.
| | - Edoardo Mazza
- EMPA, Swiss Federal Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600, Dübendorf, Switzerland. .,Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.
| |
Collapse
|
7
|
Bartoli CR, Kang J, Motomura T. Decreased RPM reduces von Willebrand factor degradation with the EVAHEART LVAS: implications for device-specific LVAD management. J Card Surg 2020; 35:1477-1483. [PMID: 32652785 DOI: 10.1111/jocs.14620] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2020] [Revised: 04/16/2020] [Accepted: 04/29/2020] [Indexed: 12/13/2022]
Abstract
BACKGROUND Continuous-flow left ventricular assist devices (LVADs) produces supraphysiologic shear stress that causes von Willebrand factor (VWF) degradation and a bleeding diathesis. Reduction of revolutions per minute (RPM) with axial-flow LVADs does not decrease shear stress enough to reduce VWF degradation and bleeding. However, it is unknown if RPM reduction with centrifugal flow LVADs may minimize VWF degradation. We tested the hypothesis that RPM reduction preserves VWF multimers in the centrifugal-flow EVAHEART left ventricular assist system (LVAS), which is designed to minimize shear stress and blood trauma. METHODS Whole blood samples were collected from humans (n = 28). Blood was circulated in ex vivo mock circulatory loops for 6 hours with an EVAHEART LVAS at 2300 (n = 12), 2100 (n = 8), or 1800 RPM (n = 8). Immunoblotting was used to resolve and quantify VWF multimers and degradation fragments. RESULTS RPM reduction from 2300 to 2100 to 1800 RPM significantly decreased EVAHEART blood flow from 5.8 ± 0.4 to 4.3 ± 0.6 to 4.1 ± 0.5 L/min (analysis of variance [ANOVA], P = .03). RPM reduction protected VWF from pathologic degradation. At lower RPMs, significantly greater levels of VWF multimers were observed (ANOVA, P = .001). Similarly, at lower RPMs, significantly fewer VWF fragments, a product of VWF degradation, were observed (ANOVA, P = .007). CONCLUSIONS RPM reduction significantly reduced VWF degradation with the centrifugal-flow EVAHEART LVAS, an LVAD specifically designed with low shear stress. Different LVADs have unique hematologic footprints and should be managed with device-specific protocols. Adjustment of RPM to minimize blood trauma while still maintaining physiologic hemodynamics has the potential to decrease complications related to LVAD-associated von Willebrand's disease, such as gastrointestinal bleeding and hemorrhagic stroke.
Collapse
Affiliation(s)
- Carlo R Bartoli
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Jooeun Kang
- MD-PhD Program, Vanderbilt University, Nashville, Tennessee
| | | |
Collapse
|
8
|
Review and reflections about pulsatile ventricular assist devices from history to future: concerning safety and low haemolysis-still needed. J Artif Organs 2020; 23:303-314. [PMID: 32367384 PMCID: PMC7666270 DOI: 10.1007/s10047-020-01170-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Accepted: 04/13/2020] [Indexed: 11/23/2022]
Abstract
Since the first use of a ventricular assist device in 1963 many extracorporeal and implantable pulsatile blood pumps have been developed. After the invention of continuous flow blood pumps the implantable pulsatile pumps are not available anymore. The new rotary pumps spend a better quality of life because many of the patients can go home. Nevertheless, the extracorporeal pulsatile pumps have some advantages. They are low-cost systems, produce less haemolysis and heart-recovery can be tested easily. Pump failure is easy to realize because the pumps can be observed visually. Pump exchange can be done easily without any chirurgic surgery. As volume displacement pumps they can produce high blood pressure, so they are the only ones suitable for pediatric patients. Therefore, they are indispensable for clinical use today and in the future. In this work, nearly all pulsatile blood pumps used in clinical life are described.
Collapse
|
9
|
Stöhr EJ, Cornwell W, Kanwar M, Cockcroft JR, McDonnell BJ. Bionic women and men - Part 1: Cardiovascular lessons from heart failure patients implanted with left ventricular assist devices. Exp Physiol 2020; 105:749-754. [PMID: 32104940 PMCID: PMC9089457 DOI: 10.1113/ep088323] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Accepted: 02/19/2020] [Indexed: 12/17/2022]
Abstract
NEW FINDINGS What is the topic of this review? Patients with advanced heart failure who are implanted with left ventricular assist devices (LVADs) present an opportunity to understand the human circulation under extreme conditions. What advances does it highlight? LVAD patients have a unique circulation that is characterized by a reduced or even absent arterial pulse. The remarkable survival of these patients is accompanied by circulatory complications, including stroke, gastrointestinal bleeding and right-heart failure. Understanding the mechanisms related to the complications in LVAD patients will help the patients and also advance our fundamental understanding of the human circulation in general. ABSTRACT Some humans with chronic, advanced heart failure are surgically implanted with a left ventricular assist device (LVAD). Because the LVAD produces a continuous flow, a palpable pulse is often absent in these patients. This allows for a unique investigation of the human circulation and has created a controversy around the 'need' for a pulse. The medical debate has also generated a more generic, fundamental discussion into what is 'normal' arterial physiology and health. The comprehensive study and understanding of the arterial responses to drastically altered haemodynamics due to continuous-flow LVADs, at rest and during activity, presents an opportunity to significantly increase our current understanding of the fundamental components of arterial regulation (flow, blood pressure, sympathetic activity, endothelial function, pulsatility) in a way that could never have been studied previously. In a series of four articles, we summarize the talks presented at the symposium entitled 'Bionic women and men - Physiology lessons from implantable cardiac devices' presented at the 2019 Annual Meeting of The Physiological Society in Aberdeen, UK. The articles highlight the novel questions generated by physiological phenomena observed in LVAD patients and propose future areas of interest within the field of cardiovascular physiology.
Collapse
Affiliation(s)
- Eric J. Stöhr
- School of Sport & Health Sciences, Cardiff Metropolitan University, Cardiff, CF5 2YB, UK
- Department of Medicine, Division of Cardiology, Columbia University Irving Medical Center, New York City, NY, USA
| | - William Cornwell
- Department of Medicine-Cardiology. University of Colorado Anschutz Medical Campus, Aurora, CO, USA
| | - Manreet Kanwar
- Cardiovascular Institute, Allegheny Health Network, Pittsburgh, PA, USA
| | - John R. Cockcroft
- School of Sport & Health Sciences, Cardiff Metropolitan University, Cardiff, CF5 2YB, UK
| | - Barry J. McDonnell
- School of Sport & Health Sciences, Cardiff Metropolitan University, Cardiff, CF5 2YB, UK
| |
Collapse
|
10
|
Acquired von Willebrand Syndrome in Pediatric Extracorporeal Membrane Oxygenation: Sheared and Cleaved Everywhere, but What to Do About It? Pediatr Crit Care Med 2019; 20:998-999. [PMID: 31580279 DOI: 10.1097/pcc.0000000000002021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
Hwang KY, Hwang NC. Facilitating noncardiac surgery for the patient with left ventricular assist device: A guide for the anesthesiologist. Ann Card Anaesth 2019; 21:351-362. [PMID: 30333327 PMCID: PMC6206808 DOI: 10.4103/aca.aca_239_17] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The introduction of left ventricular assist device (LVAD) has improved survival rates for patients with end-stage heart failure. Two categories of VADs exist: one generates pulsatile flow and the other produces nonpulsatile continuous flow. Survival is better for patients with continuous-flow LVADs. With improved survival, more of such patients now present for noncardiac surgery (NCS). This review, written for the general anesthesiologists, addresses the perioperative considerations when the patient undergoes NCS. For best outcomes, a multidisciplinary approach is essential in perioperative management of the patient.
Collapse
Affiliation(s)
- Kai-Yin Hwang
- Department of Anaesthesiology, Singapore General Hospital, 1 Hospital Drive, Singapore 169608, Singapore
| | - Nian-Chih Hwang
- Department of Anaesthesiology, Singapore General Hospital, 1 Hospital Drive, Singapore 169608; Department of Cardiothoracic Anaesthesia, National Heart Centre, Singapore, 5 Hospital Drive, Singapore 169609, Singapore
| |
Collapse
|
12
|
Rauch A, Susen S, Zieger B. Acquired von Willebrand Syndrome in Patients With Ventricular Assist Device. Front Med (Lausanne) 2019; 6:7. [PMID: 30805339 PMCID: PMC6371037 DOI: 10.3389/fmed.2019.00007] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2018] [Accepted: 01/11/2019] [Indexed: 01/27/2023] Open
Abstract
During the last decade the use of ventricular assist devices (VADs) for patients with severe heart failure has increased tremendously. However, flow disturbances, mainly high shear induced by the device is associated with bleeding complications. Shear stress-induced changes in VWF conformation are associated with a loss of high molecular weight multimers (HMW) of VWF and an increased risk of bleeding. This phenomenon and its cause will be elaborated and reviewed in the following.
Collapse
Affiliation(s)
- Antoine Rauch
- INSERM, U1011, Univ. Lille, U1011-EGID, Institut Pasteur de Lille, Lille, France.,CHU Lille, Hematology and Transfusion, Lille, France
| | - Sophie Susen
- INSERM, U1011, Univ. Lille, U1011-EGID, Institut Pasteur de Lille, Lille, France.,CHU Lille, Hematology and Transfusion, Lille, France
| | - Barbara Zieger
- Division of Pediatric Hematology and Oncology, Department of Pediatrics and Adolescent Medicine, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Freiburg, Germany
| |
Collapse
|
13
|
Jhun CS, Siedlecki C, Xu L, Lukic B, Newswanger R, Yeager E, Reibson J, Cysyk J, Weiss W, Rosenberg G. Stress and Exposure Time on von Willebrand Factor Degradation. Artif Organs 2018; 43:199-206. [PMID: 30374981 DOI: 10.1111/aor.13323] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 05/14/2018] [Accepted: 06/22/2018] [Indexed: 12/13/2022]
Abstract
Despite the prevailing use of the continuous flow left ventricular assist devices (cf-LVAD), acquired von Willebrand syndrome (AvWS) associated with cf-LVAD still remains a major complication. As AvWS is known to be dependent on shear stress (τ) and exposure time (texp ), this study examined the degradation of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in terms of τ and texp . Two custom apparatus, i.e., capillary-tubing-type degrader (CTD) and Taylor-Couette-type degrader (TCD) were developed for short-term (0.033 sec ≤ texp ≤ 1.05 s) and long-term (10 s ≤ texp ≤ 10 min) shear exposures of vWF, respectively. Flow conditions indexed by Reynolds number (Re) for CTD were 14 ≤ Re ≤ 288 with corresponding laminar stress level of 52 ≤ τ CTD ≤ 1042 dyne/cm2 . Flow conditions for TCD were 100 ≤ Re ≤ 2500 with corresponding rotor speed of 180 ≤ o ≤ 4000 RPM and laminar stress level of 50 ≤ τ TCD ≤ 1114 dyne/cm2 . Due to transitional and turbulent flows in TCD at Re > 1117, total stress (i.e., τ total = laminar + turbulent) was also calculated using a computational fluid dynamics (CFD) solver, Converge CFD (Converge Science Inc., Madison, WI, USA). Inhibition of ADAMTS13 with different concentration of EDTA (5 mM and 10 mM) was also performed to investigate the mechanism of cleavage in terms of mechanical and enzymatic aspects. Degradation of HMWM with CTD was negligible at all given testing conditions. Although no degradation of HMWM was observed with TCD at Re < 1117 ( τ total = 1012 dyne/cm2 ), increase in degradation of HMWM was observed beyond Re of 1117 for all given exposure times. At Re ~ 2500 ( τ total = 3070 dyne/cm2 ) with texp = 60 s, a severe degradation of HMWM (90.7 ± 3.8%, abnormal) was observed, and almost complete degradation of HMWM (96.1 ± 1.9%, abnormal) was observed with texp = 600 s. The inhibition studies with 5 mM EDTA at Re ~ 2500 showed that loss of HMWM was negligible (<10%, normal) for all given exposure times except for texp = 10 min (39.5 ± 22.3%, borderline-abnormal). With 10 mM EDTA, no degradation of HMWM was observed (11.1 ± 4.4%, normal) even for texp = 10 min. This study investigated the effect of shear stress and exposure time on the HMWM of vWF in laminar and turbulent flows. The inhibition study by EDTA confirms that degradation of HMWM is initiated by shear-induced unfolding followed by enzymatic cleavage at given conditions. Determination of magnitude of each mechanism needs further investigation. It is also important to note that the degradation of vWF is highly dependent on turbulence regardless of the time exposed within our testing conditions.
Collapse
Affiliation(s)
- Choon-Sik Jhun
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - Christopher Siedlecki
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA.,Department of Biomedical Engineering, Penn State University, University Park, PA, USA
| | - Lichong Xu
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - Branka Lukic
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - Raymond Newswanger
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - Eric Yeager
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - John Reibson
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - Joshua Cysyk
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA
| | - William Weiss
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA.,Department of Biomedical Engineering, Penn State University, University Park, PA, USA
| | - Gerson Rosenberg
- Division of Applied Biomedical Engineering, Department of Surgery, Penn State College of Medicine, Hershey PA, USA.,Department of Biomedical Engineering, Penn State University, University Park, PA, USA
| |
Collapse
|
14
|
Rosenberg G, Siedlecki CA, Jhun CS, Weiss WJ, Manning K, Deutsch S, Pierce W. Acquired Von Willebrand Syndrome and Blood Pump Design. Artif Organs 2018; 42:1119-1124. [DOI: 10.1111/aor.13291] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 04/05/2018] [Accepted: 04/30/2018] [Indexed: 12/27/2022]
Affiliation(s)
- Gerson Rosenberg
- Department of Surgery; The Pennsylvania State University; College of Medicine; Hershey
| | | | - Choon-Sik Jhun
- Department of Surgery; The Pennsylvania State University; College of Medicine; Hershey
| | - William J. Weiss
- Department of Surgery; The Pennsylvania State University; College of Medicine; Hershey
| | - Keefe Manning
- Biomedical Engineering; The Pennsylvania State University; University Park
| | - Steven Deutsch
- Applied Research Laboratory; The Pennsylvania State University; University Park PA, USA
| | - William Pierce
- Department of Surgery; The Pennsylvania State University; College of Medicine; Hershey
| |
Collapse
|
15
|
Kang J, Hennessy-Strahs S, Kwiatkowski P, Bermudez CA, Acker MA, Atluri P, McConnell PI, Bartoli CR. Continuous-Flow LVAD Support Causes a Distinct Form of Intestinal Angiodysplasia. Circ Res 2017; 121:963-969. [DOI: 10.1161/circresaha.117.310848] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2017] [Revised: 07/17/2017] [Accepted: 07/20/2017] [Indexed: 12/15/2022]
Abstract
Rationale:
The objective of this autopsy study was to determine whether gastrointestinal angiodysplasia develops during continuous-flow left ventricular assist device (LVAD) support.
Objective:
LVAD support causes pathologic degradation of von Willebrand factor (vWF) and bleeding from gastrointestinal angiodysplasia at an alarming rate. It has been speculated that LVAD support itself may cause angiodysplasia. The relationship to abnormal vWF metabolism is unknown. We tested the hypothesis that abnormal gastrointestinal vascularity develops during continuous-flow LVAD support.
Methods and Results:
Small bowel was obtained from deceased humans, cows, and sheep supported with a continuous-flow LVAD (n=9 LVAD, n=11 control). Transmural sections of jejunum were stained with fluorescein isothiocyanate–conjugated isolectin-B4 for endothelium to demarcate vascular structures and quantify intestinal vascularity. Paired plasma samples were obtained from humans before LVAD implantation and during LVAD support (n=41). vWF multimers and degradation fragments were quantified with agarose and polyacrylamide gel electrophoresis and immunoblotting. Abnormal vascular architecture was observed in the submucosa of the jejunum of human patients, cows, and sheep supported with a continuous-flow LVAD. Intestinal vascularity was significantly higher after LVAD support versus controls (5.2±1.0% versus 2.1±0.4%,
P
=0.004). LVAD support caused significant degradation of high–molecular-weight vWF multimers (–9±1%,
P
<0.0001) and accumulation of low–molecular-weight vWF multimers (+40±5%,
P
<0.0001) and vWF degradation fragments (+53±6%,
P
<0.0001).
Conclusions:
Abnormal intestinal vascular architecture and LVAD-associated vWF degradation were consistent findings in multiple species supported with a continuous-flow LVAD. These are the first direct evidence that LVAD support causes gastrointestinal angiodysplasia. Pathologic vWF metabolism may be a mechanistic link between LVAD support, abnormal angiogenesis, gastrointestinal angiodysplasia, and bleeding.
Collapse
Affiliation(s)
- Jooeun Kang
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Samson Hennessy-Strahs
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Pawel Kwiatkowski
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Christian A. Bermudez
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Michael A. Acker
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Pavan Atluri
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Patrick I. McConnell
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| | - Carlo R. Bartoli
- From the MD/PhD Program, Vanderbilt University School of Medicine, Nashville, TN (J.K.); Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia (J.K., S.H.-S., C.A.B., M.A.A., P.A., C.R.B.); and The Ohio State University, Columbus (P.K., P.I.M.)
| |
Collapse
|
16
|
Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device. Med Eng Phys 2017; 47:47-54. [DOI: 10.1016/j.medengphy.2017.06.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Revised: 06/05/2017] [Accepted: 06/14/2017] [Indexed: 01/17/2023]
|
17
|
Scardulla F, Pasta S, D’Acquisto L, Sciacca S, Agnese V, Vergara C, Quarteroni A, Clemenza F, Bellavia D, Pilato M. Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flow analyses. J Heart Lung Transplant 2017; 36:906-913. [DOI: 10.1016/j.healun.2017.03.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 02/17/2017] [Accepted: 03/22/2017] [Indexed: 11/27/2022] Open
|
18
|
Bartoli CR, Kang J, Zhang D, Howard J, Acker M, Atluri P, Motomura T. Left Ventricular Assist Device Design Reduces von Willebrand Factor Degradation: A Comparative Study Between the HeartMate II and the EVAHEART Left Ventricular Assist System. Ann Thorac Surg 2017; 103:1239-1244. [DOI: 10.1016/j.athoracsur.2016.06.112] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2016] [Revised: 06/01/2016] [Accepted: 06/22/2016] [Indexed: 11/25/2022]
|
19
|
Nowak-Machen M, Schmid E, Schlensak C, Consferent C, Haeberle HA, Rosenberger P, Magunia H, Hilberath JN. Safety of transesophageal echocardiography during extracorporeal life support. Perfusion 2016; 31:634-639. [PMID: 27125828 DOI: 10.1177/0267659116647472] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
INTRODUCTION: Use of extracorporeal life support (ECLS) has significantly increased in critically ill patients refractory to medical management. ECLS requires systemic anticoagulation to avoid thromboembolic complications and superimposed coagulopathies are common. Transesophageal echocardiography (TEE) is frequently employed to assess cannula position and cardiac function during extracorporeal therapy. The goal of this study was to assess whether TEE probe insertion and removal in systemically anticoagulated ECLS patients was safe compared to patients without ECLS and normal coagulation studies. METHODS: Eighty-seven separate TEE examinations in 53 adult ECLS patients were analyzed. Detailed complication profiles were logged for each patient from initiation through discontinuation of ECLS. Routine coagulation testing was recorded within two hours prior to the TEE exams. Controls consisted of age- and gender-matched patients undergoing perioperative TEE without ECLS and normal coagulation (N=87). RESULTS: Overall TEE-associated morbidity in ECLS patients was 2.3% and consisted of minor oropharyngeal bleeding (2/87 TEE exams) exclusively. The patients presenting with oropharyngeal bleeding received heparin for anticoagulation and had two or more abnormal coagulation studies at the time of TEE. Seventy-nine percent of ECLS patients received intravenous heparin infusions, 6.8% argatroban and 3.4% epoprostenol. Ten-point-eight percent of patients were not anticoagulated at the time of TEE because of pre-existing bleeding complications and/or deranged plasmatic coagulation profiles. No major complications (e.g., esophageal perforation, gastrointestinal bleeding, accidental extubation) were recorded in either group. CONCLUSIONS: TEE remained safe in critically ill patients under ECLS, despite systemic anticoagulation, during probe insertion, manipulation and removal. TEE-related complications pertained solely to oropharyngeal bleeding amenable to conservative management.
Collapse
Affiliation(s)
- Martina Nowak-Machen
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| | - Eckhard Schmid
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| | - Christian Schlensak
- 2 Division of Cardiothoracic and Vascular Surgery, Eberhard Karls University, Tübingen, Germany
| | - Crina Consferent
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| | - Helene A Haeberle
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| | - Peter Rosenberger
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| | - Harry Magunia
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| | - Jan N Hilberath
- 1 Department of Anesthesiology and Critical Care Medicine, Eberhard Karls University, Tübingen, Germany
| |
Collapse
|
20
|
Kang J, Zhang DM, Restle DJ, Kallel F, Acker MA, Atluri P, Bartoli CR. Reduced continuous-flow left ventricular assist device speed does not decrease von Willebrand factor degradation. J Thorac Cardiovasc Surg 2016; 151:1747-1754.e1. [DOI: 10.1016/j.jtcvs.2016.01.031] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 01/09/2016] [Accepted: 01/15/2016] [Indexed: 02/07/2023]
|
21
|
Inhibition of ADAMTS-13 by Doxycycline Reduces von Willebrand Factor Degradation During Supraphysiological Shear Stress. JACC-HEART FAILURE 2015; 3:860-9. [DOI: 10.1016/j.jchf.2015.06.016] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 06/08/2015] [Accepted: 06/12/2015] [Indexed: 11/19/2022]
|
22
|
Restle DJ, Zhang DM, Hung G, Howard JL, Kallel F, Acker MA, Atluri P, Bartoli CR. Preclinical Models for Translational Investigations of Left Ventricular Assist Device-Associated von Willebrand Factor Degradation. Artif Organs 2015; 39:569-75. [PMID: 25810063 DOI: 10.1111/aor.12428] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Evidence suggests a major role for von Willebrand factor (vWF) in left ventricular assist device (LVAD)-associated bleeding. However, the mechanisms of vWF degradation during LVAD support are not well understood. We developed: (i) a simple and inexpensive vortexer model; and (ii) a translational LVAD mock circulatory loop to perform preclinical investigations of LVAD-associated vWF degradation. Whole blood was obtained from LVAD patients (n = 8) and normal humans (n = 15). Experimental groups included: (i) blood from continuous-flow LVAD patients (baseline vs. post-LVAD, n = 8); (ii) blood from normal humans (baseline vs. 4 h in vitro laboratory vortexer, ∼ 2400 rpm, shear stress ∼175 dyne/cm(2) , n = 8); and (iii) blood from normal humans (baseline vs. 12 h HeartMate II mock circulatory loop, 10 000 rpm, n = 7). vWF multimers and degradation fragments were characterized with electrophoresis and immunoblotting. Blood from LVAD patients, blood exposed to in vitro supraphysiologic shear stress, and blood circulated through an LVAD mock circulatory loop demonstrated a similar profile of decreased large vWF multimers and increased vWF degradation fragments. A laboratory vortexer and an LVAD mock circulatory loop reproduced the pathologic degradation of vWF that occurs during LVAD support. Both models are appropriate for preclinical studies of LVAD-associated vWF degradation.
Collapse
Affiliation(s)
- David J Restle
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - David M Zhang
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - George Hung
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Jessica L Howard
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | | | - Michael A Acker
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Pavan Atluri
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Carlo R Bartoli
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
23
|
Kavoussi SC, Liu J. Spontaneous hyphema and pupillary block in a patient with a left ventricular assist device. Digit J Ophthalmol 2015; 21:1-9. [PMID: 27330463 DOI: 10.5693/djo.02.2015.04.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The left ventricular assist device (LVAD) has been a standard of care for the management of patients with advanced heart failure since the 1990s. An increased risk of spontaneous bleeding related to the device has been noted, ranging from minor epistaxis to major thoracic and mediastinal hemorrhages. To our knowledge, intraocular hemorrhage has not been previously reported. We report a 72-year-old patient with an LVAD who subsequently developed a spontaneous intraocular hemorrhage that manifested as hyphema, pupillary block, and acute intraocular pressure elevation.
Collapse
Affiliation(s)
- Shaheen C Kavoussi
- Department of Ophthalmology and Visual Science, Yale University School of Medicine, New Haven, Connecticut
| | - Ji Liu
- Department of Ophthalmology and Visual Science, Yale University School of Medicine, New Haven, Connecticut
| |
Collapse
|
24
|
Bartoli CR, Restle DJ, Zhang DM, Acker MA, Atluri P. Pathologic von Willebrand factor degradation with a left ventricular assist device occurs via two distinct mechanisms: Mechanical demolition and enzymatic cleavage. J Thorac Cardiovasc Surg 2015; 149:281-9. [DOI: 10.1016/j.jtcvs.2014.09.031] [Citation(s) in RCA: 67] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2014] [Revised: 08/21/2014] [Accepted: 09/04/2014] [Indexed: 02/04/2023]
|
25
|
Fiore M, James C, Mouton C, Calderon J, Barandon L, Ouattara A, Picard F. Assessment of platelet function with light transmission aggregometry in 24 patients supported with a continuous-flow left ventricular assist device: A single-center experience. J Thorac Cardiovasc Surg 2014; 148:3119-25.e1. [DOI: 10.1016/j.jtcvs.2014.07.091] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Revised: 06/09/2014] [Accepted: 07/12/2014] [Indexed: 10/24/2022]
|
26
|
Abstract
Mechanical circulatory support of the failing heart has become an important means of treating end-stage heart disease. This rapidly growing therapeutic field has produced impressive clinical outcomes and has great potential to help thousands of otherwise terminal patients worldwide. In this review, we examine the state of the art of mechanical circulatory support: current practice, totally implantable systems of the future, evolving biventricular support mechanisms, the potential for myocardial recovery and adjunctive treatment methods, and miniaturized devices with expanded indications for therapy.
Collapse
Affiliation(s)
- Hari R Mallidi
- Department of Surgery, Baylor College of Medicine; and Center for Cardiac Support, Texas Heart Institute; Houston, Texas 77030
| | - Jatin Anand
- Department of Surgery, Baylor College of Medicine; and Center for Cardiac Support, Texas Heart Institute; Houston, Texas 77030
| | - William E Cohn
- Department of Surgery, Baylor College of Medicine; and Center for Cardiac Support, Texas Heart Institute; Houston, Texas 77030
| |
Collapse
|
27
|
Kilercik M, Coskun A, Serteser M, Inan D, Unsal I. Biological variations of ADAMTS13 and von Willebrand factor in human adults. Biochem Med (Zagreb) 2014; 24:138-45. [PMID: 24627722 PMCID: PMC3936977 DOI: 10.11613/bm.2014.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Accepted: 01/15/2014] [Indexed: 12/22/2022] Open
Abstract
Background: The ultra-large von Willebrand factor (vWF) multimers are very active and must be degraded by ADAMTS13 for optimal activity. A severe functional deficiency of ADAMTS13 has been associated with thrombotic thrombocytopenic purpura. The correct interpretation of patient vWF and ADAMTS13 plasma levels requires an understanding of the biological variation associated with these analytes. In the present paper, we aimed to determine the biological variation of ADAMTS13 and vWF in human adults. Materials and methods: Blood samples were collected weekly from 19 healthy subjects for 5 consecutive weeks. vWF activity and antigenicity were determined using aggregometric and immunoturbidimetric methods. ADAMTS13 antigenicity and activity were determined by ELISA. Results: The within-subject biological variations for vWF activity and antigenicity were 8.06% and 14.37%, respectively, while the between-subject biological variations were 18.5% and 22.59%, respectively. The index of individuality for vWF activity was 0.44, while vWF antigenicity was 0.64. Similarly, ADAMTS13 activity and antigenicity within-subject biological variations were 12.73% and 9.75%, respectively, while between-subject biological variations were 9.63% and 6.28%, respectively. The ADAMTS13 indexes of individuality were 1.32 and 1.55, respectively. Conclusion: We report high biological variation and individuality in vWF antigenicity and activity levels. However, ADAMTS13 antigenicity and activity displayed high biological variation, but low individuality. Thus, population-based reference intervals may be useful for monitoring ADAMTS13 antigenicity and activity, but not for vWF, which displays high individuality. These findings should be considered when determining the reference interval and other clinical variables associated with ADAMTS13 and vWF levels.
Collapse
Affiliation(s)
- Meltem Kilercik
- Acibadem University, School of Medicine, Department of Medical Biochemistry, Istanbul, Turkey
| | - Abdurrahman Coskun
- Acibadem University, School of Medicine, Department of Medical Biochemistry, Istanbul, Turkey
| | - Mustafa Serteser
- Acibadem University, School of Medicine, Department of Medical Biochemistry, Istanbul, Turkey
| | - Deniz Inan
- Marmara University, Arts and Science Faculty, Department of Statistics, Istanbul, Turkey
| | - Ibrahim Unsal
- Acibadem University, School of Medicine, Department of Medical Biochemistry, Istanbul, Turkey
| |
Collapse
|