1
|
Chang NW, Liu CA, Hong JA, Shen SH. Effect of iodized oil embolization on temperature change during cryoablation for renal cell carcinoma. MINIM INVASIV THER 2024; 33:237-244. [PMID: 38491916 DOI: 10.1080/13645706.2024.2326019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 02/06/2024] [Indexed: 03/18/2024]
Abstract
INTRODUCTION We aimed to evaluate the effect of transcatheter arterial embolization (TAE) with iodized oil (Lipiodol) on temperature change during cryoablation (CA) for renal cell carcinoma (RCC). MATERIAL AND METHODS We retrospectively reviewed patients receiving CA for RCC from February 2020 to July 2021, including those who received Lipiodol TAE prior to CA (TAE group) and those who underwent only CA with comparable clinical and tumor characteristics (non-TAE group). Clinical data and tumor characteristics of both groups were recorded. The temperature readings of each cryoprobe at every 15 s and 'time to -100 °C' were compared between the groups. RESULTS A total of 17 patients with 18 RCCs were recruited (seven in the TAE group and 11 in the non-TAE group). The 'time to -100 °C' was significantly longer in the TAE group than in the non-TAE group (64.5 ± 24.3 s vs. 48.8 ± 9.7 s, p = 0.018). Positive correlation between 'time to -100 °C' and tumor maximal diameter, RENAL nephrometry and PADUA score were observed in the non-TAE group, while no corresponding correlation was found in the TAE group. CONCLUSIONS Pre-embolization with iodized oil influences the temporal temperature changes during cryoablation by disrupting the positive correlation between the time to reach the target temperature and tumor characteristics.
Collapse
Affiliation(s)
- Nai-Wen Chang
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chien-An Liu
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Jia-An Hong
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Shu-Huei Shen
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| |
Collapse
|
2
|
Iheanacho F, Rex N, Oueidat K, Collins S, Baird GL, Kim D, Dubel GJ, Jay BS, Maxwell AWP. Prospective Margin Estimates Predict Local Tumor Progression Following Microwave Ablation of Small Renal Masses. Cardiovasc Intervent Radiol 2024; 47:200-207. [PMID: 38151603 DOI: 10.1007/s00270-023-03635-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 11/26/2023] [Indexed: 12/29/2023]
Abstract
PURPOSE To evaluate the relationship between prospectively generated ablative margin estimates and local tumor progression (LTP) among patients undergoing microwave ablation (MWA) of small renal masses (SRMs). MATERIALS AND METHODS Between 2017 and 2020, patients who underwent MWA for SRM were retrospectively identified. During each procedure, segmented kidney and tumor shapes were coregistered with intraprocedural helical CT images obtained after microwave antenna placement. Predicted ablation zone shape and size were then overlaid onto the resultant model, and a model-to-model distance algorithm was employed to calculate multiple ablative margin estimates. LTP was modeled as a function of each margin estimate by hazard regression. Models were evaluated using hazard ratios and Akaike information criterion. Receiver operating characteristic curve area under the curve was also estimated using Harrell's and Uno's C indices (HI and UI, respectively). RESULTS One hundred and twenty-eight patients were evaluated (median age 72.1 years). Mean tumor diameter was 2.4 ± 0.9 cm. LTP was observed in nine (7%) patients. Analysis showed that decreased estimated margin size as measured by first quartile (Q1; 25th percentile), maximum, and average ablative margin metrics was significantly associated with risk of LTP. For every one millimeter increase in Q1, maximum, and mean ablative margin, the hazard of LTP increased 67% (HR: 1.67; 95% CI = 1.25-2.20, UI = 0.93, HI = 0.77), 32% (HR: 1.32; 95% CI 1.09-1.60; UI = 0.93; HI = 0.76), and 48% (HR: 1.48; 95% CI 1.18-1.85; UI = 0.83; HI = 0.75), respectively. CONCLUSION Prospectively generated ablative margin estimates can be used to predict the risk of local tumor progression following microwave ablation of small renal masses. LEVEL OF EVIDENCE 3: Retrospective cohort study.
Collapse
Affiliation(s)
- Franklin Iheanacho
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - Nathaniel Rex
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - Karim Oueidat
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA.
| | - Scott Collins
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - Grayson L Baird
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - DaeHee Kim
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - Gregory J Dubel
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - Bryan S Jay
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| | - Aaron W P Maxwell
- Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, 593 Eddy Street, Providence, RI, 02903, USA
| |
Collapse
|
3
|
Young S, Abamyan A, Goldberg D, Hannallah J, Schaub D, Kalarn S, Fitzgerald Z, Woodhead G. Cryoablation in the liver: how accurately does the iceball predict the ablation zone? Abdom Radiol (NY) 2024; 49:625-630. [PMID: 38036773 DOI: 10.1007/s00261-023-04117-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 10/23/2023] [Accepted: 10/26/2023] [Indexed: 12/02/2023]
Abstract
PURPOSE To evaluate the accuracy with which the iceball predicts the realized ablation zone in patients undergoing cryoablation of the liver. MATERIALS AND METHODS Continuous patients who underwent cryoablation of primary or secondary malignancies of the liver were retrospectively reviewed. Iceball and ablation zone dimensions on 1 month follow up imaging were collected in three orientations, the long axis (LA), perpendicular transverse (PTR), and perpendicular craniocaudal (PCC). Factors which may predict differences in the measurements were evaluated with regression analysis. Oncologic outcomes were also collected. RESULTS The mean size of the iceball was 5.5 ± 1.1 cm, 3.9 ± 1.1 cm, and 4.4 ± 1.4 cm in the LA, PTR, and PCC orientations, respectively. The mean size of the one-month ablation cavity was 4.3 ± 1.3 cm, 3 ± 1.1 cm, and 3 ± 1.3 cm in the LA, PTR, and PCC orientations, respectively. The iceball was significantly larger than the ablation zone in all orientations (p < 0.001). When comparing HCC and non-HCC patients the Kaplan-Meier analysis of TTLP, the Kaplan Meier curves deviated significantly (p = 0.015, HR 2.26 (95%CI 1.17-4.37)). When a similar analysis was performed looking at TTP again the curves diverged significantly (p = 0.002, HR 2.4 (95%CI 1.37-4.19)). CONCLUSION The iceball seems to overestimate the realized ablation zone by about 1 cm in all orientations during hepatic cryoablation.
Collapse
Affiliation(s)
- Shamar Young
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA.
| | - Art Abamyan
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| | - Dan Goldberg
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| | - Jack Hannallah
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| | - David Schaub
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| | - Salil Kalarn
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| | - Zachary Fitzgerald
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| | - Gregory Woodhead
- Division of Interventional Radiology, Department of Radiology, University of Arizona, 1501 N Campbell Ave, PO Box 245067, Tucson, AZ, 85724, USA
| |
Collapse
|
4
|
Grand T, Delavaud C, Dariane C, Ramtohul T, Guinebert S, Hélénon O, Mejean A, Timsit MO, Correas JM, Bodard S. Contrast enhancement early after renal malignancy cryoablation: imaging findings associated with benignity. Eur Radiol 2023; 33:8703-8714. [PMID: 37405502 DOI: 10.1007/s00330-023-09814-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 03/16/2023] [Accepted: 04/15/2023] [Indexed: 07/06/2023]
Abstract
OBJECTIVES Contrast enhancement by MRI done early after cryoablation for renal malignancies may suggest residual tumor (RT). However, we have observed MRI enhancement within 48 h of cryoablation in patients who had no contrast enhancement 6 weeks later. Our purpose was to identify features of 48-h contrast enhancement in patients without RT. METHODS This single-center retrospective study included consecutive patients who underwent percutaneous cryoablation of renal malignancies in 2013-2020, exhibited cryoablation-zone MRI contrast enhancement 48 h later, and had available 6-week MRI scans. Persistent or growing CE at 6 weeks vs. 48 h was classified as RT. A washout index was calculated for each 48-h MRI, and its performance for predicting RT was assessed by receiver operating characteristic curve analysis. RESULTS We included 60 patients with 72 cryoablation procedures and 83 cryoablation zones exhibiting 48-h contrast enhancement; mean age was 66 ± 17 years. Clear-cell renal cell carcinoma accounted for 95% of tumors. Of the 83 48-h enhancement zones, RT was observed in eight while 75 were benign. The 48-h enhancement was consistently visible at the arterial phase. Washout was significantly associated with RT (p < 0.001) and gradually increasing contrast enhancement with benignity (p < 0.009). A washout index below - 1.1 predicted RT with 88% sensitivity and 84% specificity. CONCLUSION MRI contrast enhancement 48 h after cryoablation of renal malignancies was usually benign. Washout was associated with residual tumor, with a washout index value below - 1.1 exhibiting good performance in predicting residual tumor. These findings may help to guide decisions about repeat cryoablation. CLINICAL RELEVANCE STATEMENT Magnetic resonance imaging contrast enhancement 48 h after cryoablation of renal malignancies rarely indicates residual tumor, which is characterized by washout with a washout index lower than - 1.1. KEY POINTS • Contrast enhancement at the arterial phase of magnetic resonance imaging done 48 h after cryoablation of a renal malignancy is usually benign. • Residual tumor manifesting as contrast enhancement at the arterial phase is characterized by subsequent marked washout. • A washout index below - 1.1 has 88% sensitivity and 84% specificity for residual tumor.
Collapse
Affiliation(s)
- Téodor Grand
- AP-HP, Hôpital Necker Enfants Malades, Service d'Imagerie Adulte, F-75015, Paris, France.
- Adult Radiology Department, Necker University Hospital, 149 Rue de Sèvres, 75015, Paris, France.
| | - Christophe Delavaud
- AP-HP, Hôpital Necker Enfants Malades, Service d'Imagerie Adulte, F-75015, Paris, France
| | - Charles Dariane
- AP-HP, Hôpital Européen Georges Pompidou, Service d'urologie, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
| | - Toulsie Ramtohul
- Institut Curie, Service de Radiologie, PSL Research University, F-75005, Paris, France
| | - Sylvain Guinebert
- AP-HP, Hôpital Necker Enfants Malades, Service d'Imagerie Adulte, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
| | - Olivier Hélénon
- AP-HP, Hôpital Necker Enfants Malades, Service d'Imagerie Adulte, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
| | - Arnaud Mejean
- AP-HP, Hôpital Européen Georges Pompidou, Service d'urologie, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
| | - Marc-Olivier Timsit
- AP-HP, Hôpital Européen Georges Pompidou, Service d'urologie, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
| | - Jean-Michel Correas
- AP-HP, Hôpital Necker Enfants Malades, Service d'Imagerie Adulte, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
- Sorbonne Université, CNRS, INSERM Laboratoire d'Imagerie Biomédicale, Paris, France
| | - Sylvain Bodard
- AP-HP, Hôpital Necker Enfants Malades, Service d'Imagerie Adulte, F-75015, Paris, France
- Université de Paris Cité, F-75006, Paris, France
- Sorbonne Université, CNRS, INSERM Laboratoire d'Imagerie Biomédicale, Paris, France
| |
Collapse
|
5
|
Moulin B, Kammoun T, Audoual R, Droupy S, Servois V, Meria P, Beregi JP, Frandon J. Single-Probe Percutaneous Cryoablation with Liquid Nitrogen for the Treatment of T1a Renal Tumors. Cancers (Basel) 2023; 15:5192. [PMID: 37958366 PMCID: PMC10648217 DOI: 10.3390/cancers15215192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 10/09/2023] [Accepted: 10/24/2023] [Indexed: 11/15/2023] Open
Abstract
Kidney cancer accounts for 3% of adult malignancies and is increasingly detected through advanced imaging techniques, highlighting the need for effective treatment strategies. This retrospective study assessed the safety and efficacy of a new single-probe percutaneous cryoablation system using liquid nitrogen for treating T1a renal cancers. From May 2019 to May 2022, 25 consecutive patients from two academic hospitals, with a median age of 64.8 years [IQR 59; 75.5], underwent cryoablation for 26 T1a renal tumors. These tumors had a median size of 25.3 mm [20; 30.7] and a median RENAL nephrometry score, indicating tumor complexity, of 7 [5; 9]. No major complications arose, but three non-clinically relevant perirenal hematomas were detected on post-procedure CT scans. With a median follow-up of 795 days [573; 1020], the primary local control rate at one month stood was 80.8% (21 out of 26). The five recurrent lesions, which exhibited a higher renal score (p = 0.016), were treated again using cryoablation, achieving a secondary local control rate of 100%. No patient died, and the disease-free survival rate was 92% (23 out of 25). In conclusion, single-probe percutaneous cryoablation emerges as a promising modality for managing small renal masses. Notably, recurrence rates appear influenced by RENAL nephrometry scores, suggesting a need for further research to refine the technique.
Collapse
Affiliation(s)
- Benjamin Moulin
- Interventional Radiology Unit, Imaging Department, Institut Curie, 26 rue d’Ulm, 75005 Paris, France; (B.M.); (V.S.)
| | - Tarek Kammoun
- Department of Medical Imaging, Nimes University Hospital, University of Montpellier, Medical Imaging Group Nimes, Place du Pr. Robert Debré, 30029 Nîmes, France; (T.K.); (J.p.B.)
| | - Regis Audoual
- Interventional Radiology Unit, Imaging Department, Institut Curie, 26 rue d’Ulm, 75005 Paris, France; (B.M.); (V.S.)
| | | | - Vincent Servois
- Interventional Radiology Unit, Imaging Department, Institut Curie, 26 rue d’Ulm, 75005 Paris, France; (B.M.); (V.S.)
| | - Paul Meria
- Urology Department, Institut Curie, 26 rue d’Ulm, 75005 Paris, France;
| | - Jean paul Beregi
- Department of Medical Imaging, Nimes University Hospital, University of Montpellier, Medical Imaging Group Nimes, Place du Pr. Robert Debré, 30029 Nîmes, France; (T.K.); (J.p.B.)
| | - Julien Frandon
- Department of Medical Imaging, Nimes University Hospital, University of Montpellier, Medical Imaging Group Nimes, Place du Pr. Robert Debré, 30029 Nîmes, France; (T.K.); (J.p.B.)
| |
Collapse
|
6
|
Knudsen JS, Duus LA, Junker T, Mussmann B, Graumann O. Percutaneous Renal Tumor Cryoablation Effect on Renal Function. J Endourol 2023; 37:1149-1155. [PMID: 37578120 DOI: 10.1089/end.2021.0959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2023] Open
Abstract
Background: Percutaneous cryoablation (PCA) of renal tumors is a well-established alternative to partial nephrectomy, but the effects on renal function after the procedure are not well-documented. The purpose of this study was to evaluate renal function after computed tomography-guided PCA. Materials and Methods: A retrospective cohort study including 259 patients treated with PCA at Odense University Hospital, Denmark from January 1, 2015 to December 31, 2019. Both patients with malignant (96%) and benign tumors (4%) were included. Mean age of patients was 66.5 years (standard deviation [SD] = 10.9, range: 27-91) and 174 (67%) patients were men. Baseline estimated glomerular filtration rate (eGFR) was recorded at baseline and 12 months after cryoablation. Results: Mean tumor size was 27.5 mm (SD = 10.0) distributed in seven different histopathological types, mainly clear cell renal-cell carcinoma (RCC) (64%) and papillary RCC (22%). Mean eGFR at baseline was 73.7 mL/min/1.73 m2 (SD = 23.2) with a follow-up mean eGFR of 69.7 (SD = 23.7) (p < 0.0001). At baseline before intervention 190 patients (73%) had eGFR matching chronic kidney disease (CKD) groups 1 and 2 (normal to mild CKD), 64 patients (24%) matching CKD group 3 (average CKD), and 1% in groups 4 and 5. At 12-month follow-up, 171 patients (66%) had eGFR matching CKD groups 1 and 2, 77 patients (30%) matching CKD group 3 and 11 patients (4%) matching CKD groups 4 and 5. In patients with skewed renography who had PCA in the kidney with better excretion, eGFR at baseline was 64.7 and 61.2 at follow-up (p = 0.703). Conclusions: This study showed minimal decline in renal function 12 months after PCA, even for patients with reduced renal function. PCA is therefore considered a safe and relevant intervention.
Collapse
Affiliation(s)
- Jens Steensen Knudsen
- Department of Medicine, Faculty of Health Sciences, University of Southern Denmark (SDU), Odense, Denmark
- Research and Innovation Unit of Radiology, SDU, Odense, Denmark
| | - Louise Aarup Duus
- Research and Innovation Unit of Radiology, SDU, Odense, Denmark
- Department of Radiology, OUH, Odense, Denmark
| | - Theresa Junker
- Research and Innovation Unit of Radiology, SDU, Odense, Denmark
| | - Bo Mussmann
- Research and Innovation Unit of Radiology, SDU, Odense, Denmark
- Department of Radiology, OUH, Odense, Denmark
- Department of Health Sciences, Faculty of Health Sciences, Oslo Metropolitan University, Oslo, Norway
| | - Ole Graumann
- Research and Innovation Unit of Radiology, SDU, Odense, Denmark
- Department of Radiology, OUH, Odense, Denmark
| |
Collapse
|
7
|
de Jager NS, van Oostenbrugge TJ, Pätz T, Jenniskens SFM, Fütterer JJ, Langenhuijsen JF, Overduin CG. Intraoperative MRI-derived volumetric ablation margins and initial correlation with local outcome after MRI-guided cryoablation of renal tumors. Cancer Imaging 2023; 23:31. [PMID: 36998028 PMCID: PMC10064595 DOI: 10.1186/s40644-023-00546-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 03/15/2023] [Indexed: 04/01/2023] Open
Abstract
PURPOSE To assess volumetric ablation margins derived from intraoperative pre- and post-ablation MRI after magnetic resonance imaging (MRI)-guided percutaneous cryoablation of renal tumors and explore its correlation with local treatment success. METHODS Retrospective analysis was performed on 30 patients (mean age 69y) who underwent percutaneous MRI-guided cryoablation between May 2014 and May 2020 for 32 renal tumors (size: 1.6-5.1 cm). Tumor and ice-ball volumes were segmented on intraprocedural pre- and post-ablation MR images using Software Assistant for Interventional Radiology (SAFIR) software. After MRI-MRI co-registration, the software automatically quantified the minimal treatment margin (MTM),defined as the smallest 3D distance between the tumor and ice-ball surface. Local tumor progression (LTP) after cryoablation was assessed on follow-up imaging. RESULTS Median follow-up was 16 months (range: 1-58). Local control after cryoablation was achieved in 26 cases (81%) while LTP occurred in 6 (19%). The intended MTM of ≥5 mm was achieved in 3/32 (9%) cases. Median MTM was significantly smaller for cases with (- 7 mm; IQR:-10 to - 5) vs. without LTP (3 mm; IQR:2 to 4) (P < .001). All cases of LTP had a negative MTM. All negative treatment margins occurred in tumors > 3 cm. CONCLUSIONS Determination of volumetric ablation margins from intraoperative MRI was feasible and may be useful in predicting local outcome after MRI-guided renal cryoablation. In our preliminary data, an intraoperative MRI-derived minimal margin extending at least 1 mm beyond the MRI-visible tumor led to local control and this was more difficult to achieve in tumors > 3 cm. Ultimately, online margin analysis may be a valuable tool to intraoperatively assess therapy success, but larger prospective studies are needed to establish a reliable threshold for clinical use.
Collapse
Affiliation(s)
- Nienke S de Jager
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, P.O. Box 9101, 6525, Nijmegen, GA, Netherlands
| | - Tim J van Oostenbrugge
- Department of Urology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, Netherlands
| | - Torben Pätz
- Fraunhofer Institute for Digital Medicine, Max-von-Laue-Str. 2, 28359, Bremen, Germany
| | - Sjoerd F M Jenniskens
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, P.O. Box 9101, 6525, Nijmegen, GA, Netherlands
| | - Jurgen J Fütterer
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, P.O. Box 9101, 6525, Nijmegen, GA, Netherlands
| | - Johan F Langenhuijsen
- Department of Urology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, Netherlands
| | - Christiaan G Overduin
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, P.O. Box 9101, 6525, Nijmegen, GA, Netherlands.
| |
Collapse
|
8
|
Duus LA, Junker T, Rasmussen BS, Bojsen JA, Pedersen AL, Anthonsen A, Lund L, Pedersen M, Graumann O. Safety, efficacy, and mid-term oncological outcomes of computed tomography-guided cryoablation of T1 renal cancer. Acta Radiol 2023; 64:814-820. [PMID: 35297745 DOI: 10.1177/02841851221081825] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
BACKGROUND Cryoablation is a promising minimally invasive, nephron-sparing treatment of small renal carcinoma (RCC) in co-morbid patients. PURPOSE To assess the safety, efficacy, and cancer-specific outcomes of computed tomography (CT)-guided cryoablation of stage T1 (RCC). MATERIAL AND METHODS A retrospective evaluation of 122 consecutive patients with 128 tumors treated with cryoablation during 2016-2017. All patients had biopsy-verified T1 RCC. RESULTS Median age was 69 years (IQR=59-76); 69% were male. Median tumor size was 26 mm (± 20-33); 9% were stage T1b. Mean follow-up time was 36.3±12.0 months. In total, 14 (11%) procedures led to complications, of which 4 (3%) were intraoperative, 5 (4%) appeared ≤30 days and 5 (4%) >30 days after treatment. Major complications arose after 4 (3%) procedures. Statistically significant associations were found between major complications and stage T1b (P = 0.039), RENAL score (P = 0.010), and number of needles used in cryoablation (P = 0.004). Residual tumor was detected after 4 (3%) procedures and 5 (4%) tumors had local tumor progression. Of 122 patients, 3 (2%) advanced to metastatic disease. Significant statistical associations were found between local tumor progression and T1b stage tumors and number of needles used in cryoablation (P = 0.05 and P = 0.004, respectively). For patients with T1a tumors, the one- and three-year disease-free survival was 98% and 95%, respectively, and for T1b 100% after one year and 75% after three years. CONCLUSIONS This study showed that cryoablation is a safe and effective treatment of stage T1 RCC and suggests that in selecting candidates for cryoablation of RCC, the tumor characteristics are more critical than patients' baseline health status.
Collapse
Affiliation(s)
- Louise A Duus
- Department of Radiology, 11286Odense University Hospital (OUH), Odense C, Denmark.,Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark.,OPEN, Odense Patient data Explorative Network, SDU, Odense C, Denmark
| | - Theresa Junker
- Department of Radiology, 11286Odense University Hospital (OUH), Odense C, Denmark.,Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark.,OPEN, Odense Patient data Explorative Network, SDU, Odense C, Denmark
| | - Benjamin S Rasmussen
- Department of Radiology, 11286Odense University Hospital (OUH), Odense C, Denmark.,Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark
| | - Jonas A Bojsen
- Department of Radiology, 11286Odense University Hospital (OUH), Odense C, Denmark.,Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark
| | - Allan L Pedersen
- Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark
| | - Andrea Anthonsen
- Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark
| | - Lars Lund
- Department of Urology, OUH, Odense C, Denmark.,Institute of Clinical Research, SDU, Odense C, Denmark
| | - Michael Pedersen
- Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark.,Comparative Medicine Lab, Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
| | - Ole Graumann
- Department of Radiology, 11286Odense University Hospital (OUH), Odense C, Denmark.,Research and Innovation Unit of Radiology, 6174University of Southern Denmark (SDU), Odense C, Denmark.,OPEN, Odense Patient data Explorative Network, SDU, Odense C, Denmark
| |
Collapse
|
9
|
Li Q, Zhang Z, Yin M, Cui C, Zhang Y, Wang Y, Liu F. What do we actually know about exosomal microRNAs in kidney diseases? Front Physiol 2022; 13:941143. [PMID: 36105281 PMCID: PMC9464820 DOI: 10.3389/fphys.2022.941143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 07/11/2022] [Indexed: 11/13/2022] Open
Abstract
There are several types of kidney diseases with complex causes. If left untreated, these diseases irreversibly progress to end-stage renal disease. Thus, their early diagnosis and targeted treatment are important. Exosomes-extracellular vesicles released by a variety of cells-are ideal carriers for DNA, RNA, proteins, and other metabolites owing to their bilayer membranes. Studies have shown that almost all renal cells can secrete exosomes. While research on exosomal microRNAs in the context of renal diseases begun only recently, rapid progress has been achieved. This review summarizes the changes in exosomal microRNA expression in different kidney diseases. Thus, it highlights the diagnostic and prognostic value of these exosomal microRNAs. Further, this review analyzes their roles in the development of different kidney diseases, guiding research on molecular mechanisms and therapeutic strategies.
Collapse
Affiliation(s)
- Qianyu Li
- Department of Nephrology, China–Japan Union Hospital of Jilin University, Changchun, China
| | - Zhiping Zhang
- Department of Nephrology, China–Japan Union Hospital of Jilin University, Changchun, China
| | - Min Yin
- Department of Nephrology, China–Japan Union Hospital of Jilin University, Changchun, China
| | - Cancan Cui
- Clinical Laboratory, China–Japan Union Hospital of Jilin University, Changchun, China
| | - Yucheng Zhang
- Scientific Research Center, China–Japan Union Hospital of Jilin University, Changchun, China
| | - Yali Wang
- Department of Blood Transfusion, China–Japan Union Hospital of Jilin University, Changchun, China
| | - Feng Liu
- Department of Nephrology, China–Japan Union Hospital of Jilin University, Changchun, China
| |
Collapse
|
10
|
Ablation zone considerations in cryoablation of RCC: accuracy of manufacturer provided model and change from first to second freeze cycle. Clin Imaging 2022; 89:10-15. [DOI: 10.1016/j.clinimag.2022.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 05/12/2022] [Accepted: 05/23/2022] [Indexed: 11/17/2022]
|
11
|
CT evaluation of patent artery after percutaneous cryoablation of renal cell carcinoma. Diagn Interv Imaging 2021; 102:753-758. [PMID: 34144934 DOI: 10.1016/j.diii.2021.06.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 05/29/2021] [Accepted: 06/01/2021] [Indexed: 11/20/2022]
Abstract
PURPOSE The purpose of this retrospective study was to determine the incidence of persistent patent artery after percutaneous cryoablation of renal cell carcinoma (RCC) and the relationship between patent arteries one month after cryoablation and early tumor progression. MATERIALS AND METHODS One hundred and fifty-nine patients (112 men, 47 women; mean age, 63.6±14.6 [SD] years; age range: 21-91 years) who underwent percutaneous cryoablation for 186 RCCs (mean diameter, 1.9±0.6 [SD] cm; range: 0.7-4.0cm) were retrospectively included. After cryoablation, patients underwent contrast-enhanced computed tomography (CT) with ≤2-mm slice thickness within one week from cryoablation, and at one, three, and six months. The time course of patent artery in the ablated renal parenchyma after cryoablation was the primary endpoint. The relationships between patent arteries one month after cryoablation and treatment effectiveness, tumor vascularity, tumor enhancement one month after cryoablation, tumor subtype, and renal function changes were evaluated as secondary endpoints. RESULTS CT showed patent arteries in the ablated renal parenchyma within one week in 166 RCCs (89.2%), at one month in 54 RCCs (29.0%), at three months in 8 RCCs (4.3%), and at six months in 2 RCCs (1.1%). The presence of patent artery one month after cryoablation was significantly associated with tumor enhancement at the same time point (P=0.015). There was no association between patent arteries one month after cryoablation and treatment effectiveness (P=0.693). CONCLUSION Patent arteries in the ablated renal parenchyma are commonly observed on CT examination after percutaneous cryoablation of RCC. However, they gradually disappear and do not require specific treatment.
Collapse
|
12
|
Seager M, Kumar S, Lim E, Munneke G, Bandula S, Walkden M. Renal cryoablation - a practical guide for interventional radiologists. Br J Radiol 2020; 94:20200854. [PMID: 32960674 DOI: 10.1259/bjr.20200854] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Renal cryoablation is a treatment option for early stage renal cell carcinomas with excellent oncological outcomes and low morbidity. This review outlines the technique of renal cryoablation and provides a guide for interventional radiologists on setting up an integrated service within a renal cancer network multidisciplinary setting. Patient selection and preparation, together with the technical aspects which ensure optimal oncological outcomes and avoid collateral damage to adjacent organs are highlighted.
Collapse
Affiliation(s)
- Matthew Seager
- Interventional Oncology Service, University College Hospital, 235 Euston Road, NW1 2BU, London, United Kingdom
| | - Shankar Kumar
- Interventional Oncology Service, University College Hospital, 235 Euston Road, NW1 2BU, London, United Kingdom.,Centre for Medical Imaging, University College London, London, UK
| | - Emma Lim
- Interventional Oncology Service, University College Hospital, 235 Euston Road, NW1 2BU, London, United Kingdom
| | - Graham Munneke
- Interventional Oncology Service, University College Hospital, 235 Euston Road, NW1 2BU, London, United Kingdom
| | - Steve Bandula
- Interventional Oncology Service, University College Hospital, 235 Euston Road, NW1 2BU, London, United Kingdom.,Centre for Medical Imaging, University College London, London, UK
| | - Miles Walkden
- Interventional Oncology Service, University College Hospital, 235 Euston Road, NW1 2BU, London, United Kingdom
| |
Collapse
|
13
|
Abstract
PURPOSE OF REVIEW With the increasing incidence of small renal masses (SRMs), ablative technologies are becoming more commonly utilized. With any nascent treatment modality, outcomes literature needs to be constantly re-evaluated. The purpose of this review is to revisit the most updated literature regarding the safety and efficacy of ablative treatments of renal lesions. RECENT FINDINGS Recent literature demonstrates that small renal tumor ablation is safe and effective. Although it does not have the same oncological efficacy of surgical extirpation, local recurrence-free survival has consistently shown to be around 90%. Cryoablation and radiofrequency ablation have longer-term data demonstrating durable responses. Microwave ablation and irreversible electroporation are promising modalities with longer-term data coming. Complication rates and procedural morbidity of ablation are consistently lower than for partial nephrectomy. SUMMARY Image-guided focal ablation is a valuable tool in the management of SRMs. Although it does not have the same efficacy of surgical extirpation, with the ability to perform repeat procedures and salvage surgery if necessary, oncologic outcomes are comparable to those of upfront surgery. Ultimately, longer-term studies and prospective trials are needed to further elucidate these modalities.
Collapse
|
14
|
Degn S, Davidsen JR, Graumann O. Cryoablation: a potential treatment option for renal metastasis from lung cancer? BMJ Case Rep 2018; 2018:bcr-2018-225841. [PMID: 30389734 DOI: 10.1136/bcr-2018-225841] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Cryoablation is successfully performed as a treatment for small renal cancers. The occurrence of a solitary renal metastasis from lung cancer is an uncommon finding entailing a limited knowledge on the choice of its optimal treatment. We present two patients diagnosed with non-small cell lung cancer, who were initially treated with curatively intended chemoradiotherapy. In the follow-up period, a non-symptomatic solitary renal metastasis was found in both patients. Both received CT-guided cryoablation of their renal metastases. One patient was successfully treated with no relapse, whereas the other patient received re-cryoablation due to development of a new renal metastasis. In both patients, no residual tumour was found at the 3 months' follow-up examination. Whether the minimally invasive procedure of cryoablation is a feasible treatment in the management of solitary renal metastases from lung cancer is still undetermined. The recurrence and incomplete treatment are concerns requiring further research.
Collapse
Affiliation(s)
- Stine Degn
- Radiology Department, Odense University Hospital, Odense, Denmark
| | | | - Ole Graumann
- Research Unit at the Department of Radiology, Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
15
|
Zhang J, Wang W, Chen S, Wang Y, Xia S. Distinct non-invasive evaluation values of tumor-derived cell-free microRNAs, circulating microvesicles and exosomal microRNAs after renal carcinoma cryoablation. Biochem Biophys Res Commun 2018; 503:1278-1283. [PMID: 30017193 DOI: 10.1016/j.bbrc.2018.07.037] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 07/07/2018] [Indexed: 12/11/2022]
Abstract
The detection of peripheral circulating tumor-derived components, such as cell-free microRNAs, circulating microvesicles, and exosomal microRNAs, has been shown as a promising noninvasive strategy. However, the different roles of these components in tumor therapy evaluations have remained largely undefined. In this paper, we employed an in vivo model of the human clear cell renal cell carcinoma line Caki-1-bearing mice to evaluate the therapeutic effects of cryoablation, which is a new minimally invasive treatment for renal cell carcinoma. At different times after cryoablation, we found that the levels of the cell-free microRNAs miR-122, miR-155 and miR-210 were first increased and then decreased. Additionally, the number of large-sized microvesicles was increased after cryoablation, but the number of small-sized circulating microvesicles did not change. Furthermore, the exosomal microRNAs miR-126-3p, miR-17-5p, and miR-21-3p rapidly decreased one day after cryoablation, an effect that was well correlated with the treatment degree. Therefore, we suggest that these circulating components may have different levels of importance in the evaluation of the efficacy of renal cell cryoablation, furthermore, exosomal microRNAs may be more suitable for the early postoperative judgment of tumor elimination effects, which are worth further exploration in clinical practice.
Collapse
Affiliation(s)
- Jie Zhang
- Department of Urology, Shanghai General Hospital of Nanjing Medical University, China; Department of Urology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, China
| | - Wenbin Wang
- Department of Urology, Shanghai General Hospital of Nanjing Medical University, China; Department of Urology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, China
| | - Shasha Chen
- Center of Translational Medicine Research, Second Military Medical University, China
| | - Yue Wang
- Center of Translational Medicine Research, Second Military Medical University, China
| | - Shujie Xia
- Department of Urology, Shanghai General Hospital of Nanjing Medical University, China; Department of Urology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, China.
| |
Collapse
|
16
|
Lamid-Ochir O, Nakajima T, Miyazaki M, Zhang X, Erdene K, Murakami T, Tsushima Y. Bioluminescence Image as a Quantitative Imaging Biomarker for Preclinical Evaluation of Cryoablation in a Murine Model. J Vasc Interv Radiol 2018; 29:1034-1040. [PMID: 29884506 DOI: 10.1016/j.jvir.2018.03.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 02/22/2018] [Accepted: 03/07/2018] [Indexed: 01/29/2023] Open
Abstract
PURPOSE To employ bioluminescence imaging (BLI) as a quantitative imaging biomarker to assess preclinical evaluation of cryoablation in a murine model. MATERIALS AND METHODS In vitro, Colon26-Luc (C26-Luc) cells were seeded at 6 different concentrations in 35-mm dishes. These were divided into 6 groups: group 0 (G0), a control group without treatment; and groups 1-5 (G1-G5) according to the number of freeze-thaw cycles, with each cycle consisting of freezing at -80°C for 10 min followed by thawing at room temperature for 5 minutes. BLI and flow-cytometric analysis were performed after cryotherapy. In vivo, 20 tumor-bearing mice with C26-Luc cells were divided into 4 groups: group 0 (G0), a control group; and groups 1-3 (G1-G3) according to the number of freeze-thaw cycles. Each cryoablation procedure was performed for 30 seconds with liquid nitrogen (-170°C) applied with cotton-tipped applicators. BLI was acquired at 6 hours and 1, 3, and 7 days after treatments. RESULTS In vitro, BLI signal showed a negative correlation with the number of freeze-thaw cycles (r = -0.86, P = .02). In vivo, there was no difference in tumor volume at 1 day after cryoablation among all groups, but the BLI signals were significantly different between G0 and G2/G3 (P = .03 and P = .02, respectively) and between G1 and G3 (P = .04). BLI signals reflected tumor growth speed and survival ratio. CONCLUSIONS This study demonstrates the direct validation of BLI as a quantitative tool for the early assessment of therapeutic effects of cryoablation.
Collapse
Affiliation(s)
- Oyunbold Lamid-Ochir
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma 371-8511, Japan
| | - Takahito Nakajima
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma 371-8511, Japan.
| | - Masaya Miyazaki
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma 371-8511, Japan
| | - Xieyi Zhang
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma 371-8511, Japan
| | - Khongorzul Erdene
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma 371-8511, Japan
| | - Takashi Murakami
- Department of Microbiology, Faculty of Medicine, Saitama Medical University, Moroyama, Japan
| | - Yoshito Tsushima
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, 3-39-22 Showa, Maebashi, Gunma 371-8511, Japan; Research Program for Diagnostic and Molecular Imaging, Division of Integrated Oncology Research, Gunma University Initiative for Advanced Research, Maebashi, Japan
| |
Collapse
|
17
|
Single 15-Min Protocol Yields the Same Cryoablation Size and Margin as the Conventional 10-8-10-Min Protocol: Results of Kidney and Liver Swine Experiment. Cardiovasc Intervent Radiol 2018; 41:1089-1094. [PMID: 29651581 DOI: 10.1007/s00270-018-1950-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Accepted: 03/28/2018] [Indexed: 10/17/2022]
Abstract
INTRODUCTION The objective was to determine the ablation size of a single 15-min freeze and compare it with the conventional 10-min freeze-8-min thaw-10-min freeze protocol. Secondary objectives were to determine the ablation margin and to ascertain whether islands of viable tissue remain within the ablation zone. MATERIALS AND METHODS Five adult swine under general anesthesia were used. After surgical abdominal exposure, two ablations were performed in liver and two in kidney. One ablation utilized the 15-min and the second the 10-8-10-min protocol. At maximum ice-ball, tissue ink was infused via an angiographic catheter in hepatic or renal artery to stain the non-frozen tissue. Animals were euthanized and organs examined macro- and microscopically. RESULTS Three histological regions were observed: (A) a viable/stained region representing the tissue outside the ice-ball, (B) a central necrotic area representing the ablated region within the ice-ball and (C) an unstained but viable margin representing the non-lethal margin within ice-ball. Ablation size did not vary with protocol but did for tissue type. Renal ablation was approximately 5 × 4 cm with both protocols, whereas liver ablation was approximately 6.7 × 4.4 cm. Ablation margin was measured at 1 mm irrespective of ablation protocol or tissue. No islands of viable tissue were identified within the ablation zone. DISCUSSION Fifteen-minute cryoablation yielded an ablation size and margin identical to that of the conventional 10-8-10-min protocol. Within the ablated region, cell death was uniform. The only difference was a larger cryoablation zone in hepatic tissue compared to renal tissue, likely attributable to differences in blood perfusion.
Collapse
|
18
|
Marcelin C, Leiner J, Nasri A, Petitpierre F, Le Bras Y, Yacoub M, Grenier N, Bernhard JC, Cornelis F. In vivo percutaneous microwave ablation in kidneys: Correlation with ex vivo data and ablation work. Diagn Interv Imaging 2017; 99:3-8. [PMID: 29066127 DOI: 10.1016/j.diii.2017.09.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Revised: 08/29/2017] [Accepted: 09/13/2017] [Indexed: 12/28/2022]
Abstract
PURPOSE To compare diameters of in vivo microwave ablation (MWA) performed in swine kidneys with ex vivo diameters, and to correlate with ablation work (AW), a new metric reflecting total energy delivered. MATERIAL AND METHODS Eighteen in vivo MWA were performed in 6 swine kidneys successively using one or two antennas (MicroThermX®). Ablation consisted in delivering power (45-120W) for 5-15minutes. Ex vivo diameters were provided by the vendors and obtained on bovine liver tissue. AW was defined as the sum of (power)*(time)*(number of antennas) for all phases of an ablation (in kJoules). Kidneys were removed laparoscopically immediately after ablation. After sacrifice, ablations zones were evaluated macroscopically, and maximum diameters of the zones were recorded. Wilcoxon sum rank test and Pearson's correlation were used for comparisons. RESULTS For a single antenna (n=12), the in vivo diameters ranged from 12 to 35mm, and 15-49mm for 2 antennas (n=6). The in vivo diameters remained shorter than ex vivo diameters by 8.6%±30.1 on 1 antenna and 11.7%±26.5 on 2 antennas (P=0.31 and 0.44, respectively). AW ranged from 13.5 to 108kJ. Diameters increased linearly with AW both with 1 and 2 antennas, but only moderate correlations were observed (r=0.43 [95% confidence interval: -0.19; 0.81], P=0.16; and 0.57 [-0.44; 0.95], P=0.24, respectively). CONCLUSION Although diameters after in vivo renal MWA increased linearly with AW, the moderate correlation and wide standard deviations observed may justify a careful imaging monitoring during treatment delivery and settings adaptation, if needed, for optimal ablation.
Collapse
Affiliation(s)
- C Marcelin
- Service d'imagerie diagnostique et thérapeutique de l'adulte, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France.
| | - J Leiner
- Service d'anatomopathologie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - A Nasri
- Service d'anatomopathologie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - F Petitpierre
- Service d'imagerie diagnostique et thérapeutique de l'adulte, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - Y Le Bras
- Service d'imagerie diagnostique et thérapeutique de l'adulte, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - M Yacoub
- Service d'anatomopathologie, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - N Grenier
- Service d'imagerie diagnostique et thérapeutique de l'adulte, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - J C Bernhard
- Service de chirurgie urologique, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - F Cornelis
- Service d'imagerie diagnostique et thérapeutique de l'adulte, hôpital Pellegrin, CHU de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France; Service de radiologie, hôpital Tenon, AP-HP, 4, rue de la Chine, 75020 Paris, France
| |
Collapse
|
19
|
van Oostenbrugge TJ, Langenhuijsen JF, Overduin CG, Jenniskens SF, Mulders PF, Fütterer JJ. Percutaneous MR Imaging–Guided Cryoablation of Small Renal Masses in a 3-T Closed-Bore MR Imaging Environment: Initial Experience. J Vasc Interv Radiol 2017; 28:1098-1107.e1. [DOI: 10.1016/j.jvir.2017.05.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2016] [Revised: 05/06/2017] [Accepted: 05/11/2017] [Indexed: 10/19/2022] Open
|
20
|
Cornelis FH, Durack JC, Kimm SY, Wimmer T, Coleman JA, Solomon SB, Srimathveeravalli G. A Comparative Study of Ablation Boundary Sharpness After Percutaneous Radiofrequency, Cryo-, Microwave, and Irreversible Electroporation Ablation in Normal Swine Liver and Kidneys. Cardiovasc Intervent Radiol 2017; 40:1600-1608. [PMID: 28516273 DOI: 10.1007/s00270-017-1692-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Accepted: 05/03/2017] [Indexed: 02/08/2023]
Abstract
PURPOSE To compare ablation boundary sharpness after percutaneous radiofrequency ablation (RFA), cryoablation (CA), microwave ablation (MWA) and irreversible electroporation (IRE) ablation in normal swine liver and kidney. MATERIALS AND METHODS Percutaneous CT-guided RFA (n = 5), CA (n = 5), MWA (n = 5) and IRE (n = 5) were performed in the liver and kidney of four Yorkshire pigs. Parameters were chosen to produce ablations 2-3 cm in diameter with a single ablation probe. Contrast-enhanced CT imaging was performed 24 h after ablation, and animals were killed. Treated organs were removed and processed for histologic analysis with hematoxylin and eosin, and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL). Three readers independently analyzed CT, H&E and TUNEL stained images of the ablation boundary to delineate regions of (1) viable cells, (2) complete necrosis or (3) mixture of viable and necrotic cells which was defined as the transition zone (TZ). The width of TZ was compared across the techniques and organs. RESULTS Ablations appeared as non-contrast-enhancing regions on CT with sharp transition to enhancing normal tissue. On TUNEL stained slides, the mean width (μm) of the TZ after MWA was 319 ± 157 in liver and 267 ± 95 in kidney, which was significantly lower than RFA (811 ± 477 and 938 ± 429); CA (452 ± 222 and 700 ± 563); and IRE (1319 ± 682 and 1570 ± 962) (all p < 0.01). No significant differences were observed between the organs. CONCLUSION Under similar conditions, the width of the TZ at the ablation boundary varies significantly between different ablation techniques.
Collapse
Affiliation(s)
- Francois H Cornelis
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Jeremy C Durack
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Simon Y Kimm
- Department of Urology, Palo Alto Medical Foundation, Palo Alto, CA, USA
| | | | - Jonathan A Coleman
- Division of Urology, Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Stephen B Solomon
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Govindarajan Srimathveeravalli
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA. .,Weill Cornell Medical College, New York, NY, USA.
| |
Collapse
|
21
|
Percutaneous MR-guided focal cryoablation for recurrent prostate cancer following radiation therapy: retrospective analysis of iceball margins and outcomes. Eur Radiol 2017; 27:4828-4836. [PMID: 28409355 PMCID: PMC5635095 DOI: 10.1007/s00330-017-4833-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Revised: 03/02/2017] [Accepted: 03/21/2017] [Indexed: 10/29/2022]
Abstract
OBJECTIVES To evaluate iceball margins after magnetic resonance (MR)-guided focal salvage prostate cryoablation and determine the correlation with local outcome. METHODS A retrospective review was performed on 47 patients that underwent percutaneous MR-guided focal cryoablation for biopsy-proven locally recurrent prostate cancer after primary radiotherapy. Preprocedural diagnostic and intraprocedural MR images were analysed to derive three-directional iceball margins. Local tumour progression after cryoablation was defined as evident tumour recurrence on follow-up MRI, positive MR-guided biopsy or biochemical failure without radiological evidence of metastatic disease. RESULTS Mean iceball margins were 8.9 mm (range -7.1 to 16.2), 10.1 mm (range 1.1-20.3) and 12.5 mm (range -1.5 to 22.2) in anteroposterior, left-right and craniocaudal direction respectively. Iceball margins were significantly smaller for tumours that were larger (P = .008) or located in the posterior gland (P = .047). Significantly improved local progression-free survival at 1 year post focal cryoablation was seen between patients with iceball margin >10 mm (100%), 5-10 mm (84%) and <5 mm (15%) (P < .001). CONCLUSIONS Iceball margins appear to correlate with local outcome following MR-guided focal salvage prostate cryoablation. Our initial data suggest that freezing should be applied at minimum 5 mm beyond the border of an MR-visible recurrent prostate tumour for successful ablation, with a wider margin appearing desirable. KEY POINTS • Shortest iceball margin most often occurred in anteroposterior direction • Margins were smaller in tumours that were larger or posteriorly located • Minimum iceball margin was a predictor of early local tumour progression • A minimum 5-mm margin seems required for effective cryoablation of recurrent PCa.
Collapse
|
22
|
Fan WZ, Niu LZ, Wang Y, Yao XH, Zhang YQ, Tan GS, Yang JY, Li JP. Initial Experience: Alleviation of Pain with Percutaneous CT-Guided Cryoablation for Recurrent Retroperitoneal Soft-Tissue Sarcoma. J Vasc Interv Radiol 2016; 27:1798-1805. [PMID: 27617909 DOI: 10.1016/j.jvir.2016.06.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 06/16/2016] [Accepted: 06/27/2016] [Indexed: 02/07/2023] Open
Abstract
PURPOSE To evaluate the pain-alleviating effect of computed tomography (CT)-guided percutaneous cryoablation for recurrent retroperitoneal soft-tissue sarcomas (RPSs). MATERIALS AND METHODS Data from 19 men and 20 women (median age, 50.3 y) with recurrent malignant RPS who underwent percutaneous cryoablation were reviewed retrospectively. A total of 50 tumors were treated by cryoablation, including a single tumor in 29 patients, 2 tumors in 9, and 3 tumors in 1. Adverse events and analgesic outcomes were compared as a function of tumor size (< 10 cm and ≥ 10 cm). Efficacy was assessed based on modified Response Evaluation Criteria In Solid Tumors and progression-free survival (PFS). RESULTS Grade 1/2 adverse events included fever (n = 17), emesis (n = 7), frostbite (n = 5), and local pain (n = 4). The median follow-up period and PFS were 18.5 months (range, 12-42 mo) and 13.4 months ± 6.2, respectively. At the end of follow-up, 13 patients had died and 26 were living. The mean severe local pain scores on pretreatment day 1 and posttreatment days 1, 5, 10, 15, 20, and 25 were 7.49, 7.40, 6.51, 5.81, 5.35, 5.04, and 5.44, respectively, and significant differences versus pretreatment (P < .001) were reported for posttreatment days 5-25. Immediate relief occurred more frequently in the small-tumor group (4 of 7; 57.1%; P = .018), whereas delayed relief occurred more frequently in the large-tumor group (17 of 22; 77.3%; P = .030). CONCLUSIONS Minimally invasive percutaneous cryoablation improves local pain and is a feasible treatment for recurrent RPSs.
Collapse
Affiliation(s)
- Wen-Zhe Fan
- Departments of Interventional Oncology Guangzhou, China
| | - Li-Zhi Niu
- Fuda Cancer Hospital, Jinan University School of Medicine, Guangzhou, China; Fuda Institute of Cryosurgery for Cancer, Guangzhou, China
| | - Yu Wang
- Departments of Interventional Oncology Guangzhou, China
| | - Xue-Hua Yao
- Departments of Interventional Oncology Guangzhou, China
| | | | | | - Jian-Yong Yang
- Interventional Radiology, Guangzhou, China; Medical Imaging, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Jia-Ping Li
- Departments of Interventional Oncology Guangzhou, China.
| |
Collapse
|
23
|
Ablative Therapies for the Treatment of Small Renal Masses: a Review of Different Modalities and Outcomes. Curr Urol Rep 2016; 17:59. [DOI: 10.1007/s11934-016-0611-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
24
|
Chen JX, Maass D, Guzzo TJ, Bruce Malkowicz S, Wein AJ, Soulen MC, Clark TWI, Nadolski GJ, William Stavropoulos S. Tumor Growth Kinetics and Oncologic Outcomes of Patients Undergoing Active Surveillance for Residual Renal Tumor following Percutaneous Thermal Ablation. J Vasc Interv Radiol 2016; 27:1397-1406. [PMID: 27234485 DOI: 10.1016/j.jvir.2016.03.038] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 03/23/2016] [Accepted: 03/24/2016] [Indexed: 01/20/2023] Open
Abstract
PURPOSE To evaluate growth kinetics and oncologic outcomes of patients with renal tumors undergoing active surveillance (AS) for residual viable tumor following percutaneous ablation. MATERIALS AND METHODS Following percutaneous thermal ablation, residual tumor was detected in 21/133 (16%) patients on initial follow-up imaging, and AS was undertaken in 17/21 (81%) patients. Initial tumor volumes and volumes after ablation were assessed from cross-sectional imaging to calculate volumetric growth rate (VGR) and volume doubling time (VDT) of residual tumor. The rate of metastasis, overall survival, and renal cell carcinoma (RCC)-specific survival were compared between patients in the AS group and in the routine follow up group of patients who did not have residual tumor. RESULTS Median tumor volume prior to ablation, after first ablation, and at final follow-up were 25 cm(3), 6 cm(3), and 6 cm(3), respectively, in patients with residual tumor. Stable, mild, and moderate VGR occurred in 8/17 (47%), 4/17 (24%), and 5/17 (29%) cases, respectively. The 4 cases with fastest VDT underwent delayed intervention with ablation (n = 1) and nephrectomy (n = 3) without subsequent residual, recurrence, or metastasis. There was no significant difference in the rates of RCC metastasis, overall survival, or RCC-specific survival between AS and routine follow-up groups. Metastatic RCC and subsequent death occurred in 1 patient in the AS group, after the patient had refused offers for retreatment for local progression over 60.7 months of follow-up. CONCLUSIONS In cases when patients are not amenable to further intervention, AS of residual tumor may be an acceptable alternative and allows for successful delayed intervention when needed.
Collapse
Affiliation(s)
- James X Chen
- Division of Interventional Radiology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - Daniel Maass
- Division of Interventional Radiology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - Thomas J Guzzo
- Division of Urology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - S Bruce Malkowicz
- Division of Urology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - Alan J Wein
- Division of Urology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - Michael C Soulen
- Division of Interventional Radiology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - Timothy W I Clark
- Division of Interventional Radiology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - Gregory J Nadolski
- Division of Interventional Radiology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104
| | - S William Stavropoulos
- Division of Interventional Radiology, Department of Surgery, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104.
| |
Collapse
|