1
|
Priya K, Rathinasabapathi P, Arunraj R, Sugapriya D, Ramya M. Development of multiplex HRM-based loop-mediated isothermal amplification method for specific and sensitive detection of Treponema pallidum. Arch Microbiol 2022; 204:355. [PMID: 35648234 DOI: 10.1007/s00203-022-02973-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/25/2022] [Accepted: 05/11/2022] [Indexed: 11/25/2022]
Abstract
Syphilis is a sexually transmitted disease caused by the spirochaete bacterium Treponema pallidum. This study has developed a multiplex High-Resolution Melt-curve Loop-mediated isothermal amplification (multiplex HRM-LAMP) assay targeting the marker genes polA and tprL to detect T. pallidum. The multiplex HRM-LAMP assay conditions were optimized at 65 °C for 45 min. Real-time melt-curve analysis of multiplex HRM-LAMP shows two melt-curve peaks corresponding to polA and tprL with a Tm value of 80 ± 0.5 °C and 87 ± 0.5 °C, respectively. The detection limit of multiplex HRM-LAMP was found to be 6.4 × 10-4 ng/μL (3.79 copies/μL) of T. pallidum. The specificity was evaluated using seven different bacterial species, and the developed method was 100% specific in detecting T. pallidum. A total of 64 blood samples of T. pallidum suspected cases were used to validate the assay method. The clinical validation showed that the assay was 96.43% sensitive and 100% specific in detecting syphilis. Thus, the developed method was more rapid and sensitive than other available methods and provides a multigene-based diagnostic approach to detect T. pallidum.
Collapse
Affiliation(s)
- Krishnamoorthy Priya
- Molecular Genetics Laboratory, Department of Genetic Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Kanchipuram District, Chennai, Tamil Nadu, 603203, India
| | - Pasupathi Rathinasabapathi
- Molecular Genetics Laboratory, Department of Genetic Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Kanchipuram District, Chennai, Tamil Nadu, 603203, India
| | - Rex Arunraj
- Molecular Genetics Laboratory, Department of Genetic Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Kanchipuram District, Chennai, Tamil Nadu, 603203, India
| | - Dhanasekaran Sugapriya
- Department of Medical Laboratory (Pathology), College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Wadi-Al Dawaser, 11451, Riyadh, Saudi Arabia
| | - Mohandass Ramya
- Molecular Genetics Laboratory, Department of Genetic Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Kanchipuram District, Chennai, Tamil Nadu, 603203, India.
| |
Collapse
|
2
|
Peng R, Pan Y, Liu B, Li Z, Pan P, Zhang S, Qin Z, Wheeler AR, Tang XS, Liu X. Understanding Carbon Nanotube-Based Ionic Diodes: Design and Mechanism. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100383. [PMID: 34171160 DOI: 10.1002/smll.202100383] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 04/27/2021] [Indexed: 06/13/2023]
Abstract
The rectification of ion transport through biological ion channels has attracted much attention and inspired the thriving invention and applications of ionic diodes. However, the development of high-performance ionic diodes is still challenging, and the working mechanisms of ionic diodes constructed by 1D ionic nanochannels have not been fully understood. This work reports the systematic investigation of the design and mechanism of a new type of ionic diode constructed from horizontally aligned multi-walled carbon nanotubes (MWCNTs) with oppositely charged polyelectrolytes decorated at their two entrances. The major design and working parameters of the MWCNT-based ionic diode, including the ion channel size, the driven voltage, the properties of working fluids, and the quantity and length of charge modification, are extensively investigated through numerical simulations and/or experiments. An optimized ionic current rectification (ICR) ratio of 1481.5 is experimentally achieved on the MWCNT-based ionic diode. These results promise potential applications of the MWCNT-based ionic diode in biosensing and biocomputing. As a proof-of-concept, DNA detection and HIV-1 diagnosis is demonstrated on the ionic diode. This work provides a comprehensive understanding of the working principle of the MWCNT-based ionic diodes and will allow rational device design and optimization.
Collapse
Affiliation(s)
- Ran Peng
- Department of Marine Engineering, Dalian Maritime University, 1 Lingshui Road, Dalian, Liaoning, 116026, China
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario, M5S 3G8, Canada
| | - Yueyue Pan
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario, M5S 3G8, Canada
| | - Biwu Liu
- Department of Chemistry & Waterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xianning West Road, Xi'an, Shaanxi, 710049, China
| | - Zhi Li
- Department of Chemistry & Waterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Peng Pan
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario, M5S 3G8, Canada
| | - Shuailong Zhang
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
- Institute of Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario, M5S 3G9, Canada
| | - Zhen Qin
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario, M5S 3G8, Canada
| | - Aaron R Wheeler
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
- Institute of Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario, M5S 3G9, Canada
| | - Xiaowu Shirley Tang
- Department of Chemistry & Waterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, Ontario, N2L 3G1, Canada
| | - Xinyu Liu
- Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario, M5S 3G8, Canada
- Institute of Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario, M5S 3G9, Canada
| |
Collapse
|
3
|
Oudeng G, Benz M, Popova AA, Zhang Y, Yi C, Levkin PA, Yang M. Droplet Microarray Based on Nanosensing Probe Patterns for Simultaneous Detection of Multiple HIV Retroviral Nucleic Acids. ACS APPLIED MATERIALS & INTERFACES 2020; 12:55614-55623. [PMID: 33269927 PMCID: PMC7724762 DOI: 10.1021/acsami.0c16146] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 11/20/2020] [Indexed: 05/09/2023]
Abstract
Multiplexed detection of viral nucleic acids is important for rapid screening of viral infection. In this study, we present a molybdenum disulfide (MoS2) nanosheet-modified dendrimer droplet microarray (DMA) for rapid and sensitive detection of retroviral nucleic acids of human immunodeficiency virus-1 (HIV-1) and human immunodeficiency virus-2 (HIV-2) simultaneously. The DMA platform was fabricated by omniphobic-omniphilic patterning on a surface-grafted dendrimer substrate. Functionalized MoS2 nanosheets modified with fluorescent dye-labeled oligomer probes were prepatterned on positively charged amino-modified omniphilic spots to form a fluorescence resonance energy transfer (FRET) sensing microarray. With the formation of separated microdroplets of sample on the hydrophobic-hydrophilic micropattern, prepatterned oligomer probes specifically hybridized with the target HIV genes and detached from the MoS2 nanosheet surface due to weakening of the adsorption force, leading to fluorescence signal recovery. As a proof of concept, we used this microarray with a small sample size (<150 nL) for simultaneous detection of HIV-1 and HIV-2 nucleic acids with a limit of detection (LOD) of 50 pM. The multiplex detection capability was further demonstrated for simultaneous detection of five viral genes (HIV-1, HIV-2, ORFlab, and N genes of SARS-COV-2 and M gene of Influenza A). This work demonstrated the potential of this novel MoS2-DMA FRET sensing platform for high-throughput multiplexed viral nucleic acid screening.
Collapse
Affiliation(s)
- Gerile Oudeng
- Department of Biomedical
Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon 999077, Hong Kong SAR, P. R. China
| | - Maximilian Benz
- Institute of Biological and Chemical Systems—Functional Molecular
Systems (IBCS-FMS), Karlsruhe Institute
of Technology (KIT), Hermann-von Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, German
| | - Anna A. Popova
- Institute of Biological and Chemical Systems—Functional Molecular
Systems (IBCS-FMS), Karlsruhe Institute
of Technology (KIT), Hermann-von Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, German
| | - Yu Zhang
- Department
of Mechanical and Automotive Engineering, Royal Melbourne Institute of Technology University, Victoria 3000, Melbourne, Australia
| | - Changqing Yi
- Key Laboratory of
Sensing Technology and Biomedical Instruments (Guangdong Province),
School of Biomedical Engineering, Sun Yat-Sen
University, Guangzhou 510006, P. R. China
| | - Pavel A. Levkin
- Institute of Biological and Chemical Systems—Functional Molecular
Systems (IBCS-FMS), Karlsruhe Institute
of Technology (KIT), Hermann-von Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, German
| | - Mo Yang
- Department of Biomedical
Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon 999077, Hong Kong SAR, P. R. China
| |
Collapse
|
4
|
Molecular and Immunological Diagnostic Techniques of Medical Viruses. Int J Microbiol 2020; 2020:8832728. [PMID: 32908530 PMCID: PMC7474384 DOI: 10.1155/2020/8832728] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/24/2020] [Accepted: 08/15/2020] [Indexed: 01/12/2023] Open
Abstract
Viral infections are causing serious problems in human population worldwide. The recent outbreak of coronavirus disease 2019 caused by SARS-CoV-2 is a perfect example how viral infection could pose a great threat to global public health and economic sectors. Therefore, the first step in combating viral pathogens is to get a timely and accurate diagnosis. Early and accurate detection of the viral presence in patient sample is crucial for appropriate treatment, control, and prevention of epidemics. Here, we summarize some of the molecular and immunological diagnostic approaches available for the detection of viral infections of humans. Molecular diagnostic techniques provide rapid viral detection in patient sample. They are also relatively inexpensive and highly sensitive and specific diagnostic methods. Immunological-based techniques have been extensively utilized for the detection and epidemiological studies of human viral infections. They can detect antiviral antibodies or viral antigens in clinical samples. There are several commercially available molecular and immunological diagnostic kits that facilitate the use of these methods in the majority of clinical laboratories worldwide. In developing countries including Ethiopia where most of viral infections are endemic, exposure to improved or new methods is highly limited as these methods are very costly to use and also require technical skills. Since researchers and clinicians in all corners of the globe are working hard, it is hoped that in the near future, they will develop good quality tests that can be accessible in low-income countries.
Collapse
|
5
|
Zou R, Zhang F, Chen C, Cai C. DNA-programming multicolor silver nanoclusters for sensitively simultaneous detection of two HIV DNAs. SENSORS AND ACTUATORS. B, CHEMICAL 2019; 296:126608. [PMID: 32288255 PMCID: PMC7126789 DOI: 10.1016/j.snb.2019.05.085] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 05/13/2019] [Accepted: 05/23/2019] [Indexed: 05/11/2023]
Abstract
A novel DNA-stabilized silver nanoclusters (AgNCs)-based label-free fluorescent platform for simultaneously detecting two human immunodeficiency virus oligonucleotides (HIV DNAs) was developed. The sensing platform was established based on fluorescence enhancement of guanine (G)-rich and the phenomenon in the process of two silver nanoclusters (AgNCs) forming a nanoclusters dimer. The probe (AgNCs/G) utilized for HIV-1 detection adopted an effective conformation based on enhancement effect of G-rich sequence (at 500 nm ex / 565 nm em) while the probe (AgNCs/AgNCs) for HIV-2 generated fluorescence signals (at 580 nm ex / 630 nm em) with bright fluorescence only in nanoclusters dimer. The nanoprobe shows high selectivity for multiplexed analysis of target DNA with a detection limit of 11 pM, respectively. Moreover, this is the first time to use the affectivity of fluorescent AgNCs and two HIV DNAs simultaneous detection integrated into a novel method, which shows a great promise in biomedical research and early clinical diagnosis.
Collapse
Affiliation(s)
- Rong Zou
- Key Laboratory for Green Organic Synthesis and Application of Hunan Province, Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan 411105, China
| | - Feng Zhang
- College of Science, Hunan Agricultural University, Changsha, 410128, China
| | - Chunyan Chen
- Key Laboratory for Green Organic Synthesis and Application of Hunan Province, Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan 411105, China
| | - Changqun Cai
- Key Laboratory for Green Organic Synthesis and Application of Hunan Province, Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan 411105, China
- Corresponding author.
| |
Collapse
|
6
|
Arca-Lafuente S, Martínez-Román P, Mate-Cano I, Madrid R, Briz V. Nanotechnology: A reality for diagnosis of HCV infectious disease. J Infect 2019; 80:8-15. [PMID: 31580870 DOI: 10.1016/j.jinf.2019.09.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 09/26/2019] [Indexed: 01/24/2023]
Abstract
Hepatitis C virus (HCV) is the primary etiologic agent of liver cirrhosis or hepatocellular carcinoma. HCV elevated infection rates are mostly due to the lack of an accurate and accessible screening and diagnosis, especially in low- and middle-income countries. Conventional HCV diagnostic algorithm consists of a serological test followed by a nucleic acid test. This sequence of tests is time consuming and not affordable for low-resource settings. Nanotechnology have introduced new promising tests for the diagnose of infectious diseases. Based on the employment of nanoparticles and other nanomaterials which lead to highly sensitive and specific nanoscale tests, most of them target pathogen genome. Implementation of nanoscale tests, which are affordable, portable and easy to use by non-specialized personal, would improve HCV diagnosis algorithm. In this review, we have summed up the current emerging nanotechnology tools, which will improve actual screening and treatment programs, and help to reach HCV elimination proposal.
Collapse
Affiliation(s)
- Sonia Arca-Lafuente
- Laboratory of Reference and Research on Viral Hepatitis, National Center for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain; BioAssays SL, c/Faraday, 7, Parque Científico de Madrid, Campus de Cantoblanco, 28049 Madrid, Spain
| | - Paula Martínez-Román
- Laboratory of Reference and Research on Viral Hepatitis, National Center for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain
| | - Irene Mate-Cano
- Laboratory of Reference and Research on Viral Hepatitis, National Center for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain
| | - Ricardo Madrid
- BioAssays SL, c/Faraday, 7, Parque Científico de Madrid, Campus de Cantoblanco, 28049 Madrid, Spain.
| | - Verónica Briz
- Laboratory of Reference and Research on Viral Hepatitis, National Center for Microbiology, Institute of Health Carlos III, Majadahonda, Madrid, Spain.
| |
Collapse
|
7
|
Kidd M, Drozdov IA, Matar S, Gurunlian N, Ferranti NJ, Malczewska A, Bennett P, Bodei L, Modlin IM. Utility of a ready-to-use PCR system for neuroendocrine tumor diagnosis. PLoS One 2019; 14:e0218592. [PMID: 31247038 PMCID: PMC6597157 DOI: 10.1371/journal.pone.0218592] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 06/05/2019] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Multigene-based PCR tests are time-consuming and limiting aspects of the protocol include increased risk of operator-based variation. In addition, such protocols are complex to transfer and reproduce between laboratories. AIMS Evaluate the clinical utility of a pre-spotted PCR plate (PSP) for a novel multigene (n = 51) blood-based gene expression diagnostic assay for neuroendocrine tumors (NETs). METHODS A pilot study (n = 44; 8 controls and 36 NETs) was undertaken to compare CQ, normalized gene expression and algorithm-based output (NETest score). Gene expression was then evaluated between matched blood:tumor tissue samples (n = 7). Thereafter, two prospective sets (diagnostic: n = 167; clinical validation: n = 48, respectively) were evaluated for diagnostic and clinical utility value. Two independent molecular diagnostics facilities were used to assess assay reproducibility and inter-laboratory metrics. Samples were collected (per CLIA protocol) processed to mRNA and cDNA and then either run per standard assay (liquid primers) or on PSPs. Separately, matching plasma samples were analyzed for chromogranin A (CgA). Statistics included non-parametric testing, Pearson-concordance, Predictive Modeling and AUROC analyses. RESULTS In the pilot study (n = 44), CQ values were highly concordant (r: 0.82, p<0.0001) and normalized gene expression data significantly related (p<0.0001) (Pearson-pairwise correlation). NETest values were not different (49.7±33 standard vs. 48.5±31.5 PSP) and the overall concordance in output 96%. Predictive modelling confirmed this concordance (F1 score = 0.95). Gene expression levels were highly correlated between blood and tumor tissue (R: 0.71-0.83). In the diagnostic cohort (n = 30 controls, n = 87 non-NET controls, n = 50 NET), NETest was significantly lower (p<0.0001) in controls (11±6.5) and non-NET controls (13±18) than NETs (61±31). The AUROCs were 0.93-0.97 and the diagnostic accuracy was 90-97.5%. As a diagnostic, the PSP-NETest was significantly better than CgA (accuracy: 56%, p<0.0001). For clinical samples, the PSP generated robust and accurate (>96%) scores and was significantly better (p<0.0001) than CgA. The assay protocol was consistent (r: 0.97) and reproducible (co-efficient of variation: 1.3-4.2%) across the two facilities. CONCLUSION The PSP protocol for the NETest has been established and prospectively tested in clinical samples. It is highly reproducible, has similar metrics (CV, categorization by control or NET) to the standard PCR assay and generates clinically concordant (>96%) NETest results. Moreover, it functions significantly more accurately than CgA.
Collapse
Affiliation(s)
- Mark Kidd
- Wren Laboratories, Branford, Connecticut, United States of America
| | - Ignat A. Drozdov
- Wren Laboratories, Branford, Connecticut, United States of America
| | - Somer Matar
- Wren Laboratories, Branford, Connecticut, United States of America
| | | | | | | | - Philip Bennett
- Sarah Cannon Molecular Diagnostics, London, United Kingdom
| | - Lisa Bodei
- Memorial Sloan Kettering Cancer Centre, New York, New York, United States of America
| | - Irvin M. Modlin
- Yale University, School of Medicine, New Haven, Connecticut, United States of America
| |
Collapse
|