1
|
Meng X, Yuan Z, Yan T, Zheng W. Treatment of Uranyl Nitrate Solution by Nanofiltration. NUCL TECHNOL 2023. [DOI: 10.1080/00295450.2023.2169041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Affiliation(s)
- Xiang Meng
- China Institute of Atomic Energy, Department of Radiochemistry, Beijing, 102413, China
| | - Zhongwei Yuan
- China Institute of Atomic Energy, Department of Radiochemistry, Beijing, 102413, China
| | - Taihong Yan
- China Institute of Atomic Energy, Department of Radiochemistry, Beijing, 102413, China
| | - Weifang Zheng
- China Institute of Atomic Energy, Department of Radiochemistry, Beijing, 102413, China
| |
Collapse
|
2
|
Leisi R, Rostami I, Laughhunn A, Bieri J, Roth NJ, Widmer E, Ros C. Visualizing protein fouling and its impact on parvovirus retention within distinct filter membrane morphologies. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.120791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
4
|
Chen L, Deng Y, Dong S, Wang H, Li P, Zhang H, Chu W. The occurrence and control of waterborne viruses in drinking water treatment: A review. CHEMOSPHERE 2021; 281:130728. [PMID: 34010719 PMCID: PMC8084847 DOI: 10.1016/j.chemosphere.2021.130728] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/21/2021] [Accepted: 04/25/2021] [Indexed: 05/04/2023]
Abstract
As the coronavirus disease 2019 continues to spread globally, its culprit, the severe acute respiratory syndrome coronavirus 2 has been brought under scrutiny. In addition to inhalation transmission, the possible fecal-oral viral transmission via water/wastewater has also been brought under the spotlight, necessitating a timely global review on the current knowledge about waterborne viruses in drinking water treatment system - the very barrier that intercepts waterborne pathogens to terminal water users. In this article we reviewed the occurrence, concentration methods, and control strategies, also, treatment performance on waterborne viruses during drinking water treatment were summarized. Additionally, we emphasized the potential of applying the quantitative microbial risk assessment to guide drinking water treatment to mitigate the viral exposure risks, especially when the unregulated novel viral pathogens are of concern. This review paves road for better control of viruses at drinking water treatment plants to protect public health.
Collapse
Affiliation(s)
- Li Chen
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Yang Deng
- Department of Earth and Environmental Studies, Montclair State University, Montclair, NJ, USA
| | - Shengkun Dong
- Key LLaboratory of Water Cycle and Water Security in Southern China of Guangdong Higher Education Institute, School of Civil Engineering, Sun Yat-sen University, Guangdong, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Pan Li
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Huaiyu Zhang
- Central and Southern China Institute of Municipal Engineering Design and Research, Hubei, China
| | - Wenhai Chu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China.
| |
Collapse
|
5
|
Ideno S, Inoue T, Takahashi K, Urayama T, Maeno H, Takeuchi K, Sakai K. Phenotypic characterization of cell culture-derived hepatitis E virus subjected to different chemical treatments: Application in virus removal via nanofiltration. J Virol Methods 2021; 296:114244. [PMID: 34302862 DOI: 10.1016/j.jviromet.2021.114244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 07/15/2021] [Accepted: 07/16/2021] [Indexed: 12/23/2022]
Abstract
Safety evaluation for the hepatitis E virus (HEV) is required for plasma fractionation products. Plasma-derived HEV (pHEV) is quite unique in that it is associated with a lipid membrane, which, when stripped during manufacturing processes, induces morphological changes in the virus, making it difficult to select proper HEV phenotypes for clearance studies. We developed a convenient system for the preparation of a high titer cell culture-derived HEV (cHEV). In this system, PLC/PRF/5 cells transfected with the wild-type HEV genome generated lipid membrane-associated cHEV for a long period even after cryopreservation. We also examined how this lipid membrane-associated cHEV can be used to verify the robustness of pHEV removal via 19-nm nanofiltration. Sodium-deoxycholate and trypsin (NaDOC/T) treatment not only dissolved lipid but also digested membrane-associated proteins from pHEV and cHEV, making the resulting cHEV particle smaller in size than any pHEV phenotypes generated by ethanol or solvent-detergent treatment in this study. In both 19-nm and 35-nm nanofiltration, cHEV behaved identically to pHEV. These results indicate that cHEV is a useful resource for viral clearance studies in term of availability, and the use of NaDOC/T-treated cHEV ensured robust pHEV removal capacity via 19-nm nanofiltration.
Collapse
Affiliation(s)
- Shoji Ideno
- Central Research Laboratory, Research & Development Division, Japan Blood Products Organization, Kobe, Japan.
| | - Takamasa Inoue
- Central Research Laboratory, Research & Development Division, Japan Blood Products Organization, Kobe, Japan
| | - Kadue Takahashi
- Central Research Laboratory, Research & Development Division, Japan Blood Products Organization, Kobe, Japan
| | - Takeru Urayama
- Central Research Laboratory, Research & Development Division, Japan Blood Products Organization, Kobe, Japan
| | - Hideki Maeno
- Central Research Laboratory, Research & Development Division, Japan Blood Products Organization, Kobe, Japan
| | - Kaoru Takeuchi
- Laboratory of Environmental Microbiology, Division of Biomedical Science, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan
| | - Kaoru Sakai
- Central Research Laboratory, Research & Development Division, Japan Blood Products Organization, Kobe, Japan
| |
Collapse
|
6
|
Leisi R, Bieri J, Roth NJ, Ros C. Determination of parvovirus retention profiles in virus filter membranes using laser scanning microscopy. J Memb Sci 2020. [DOI: 10.1016/j.memsci.2020.118012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|