1
|
Ulsaker H, Halvorsen H, Braaten AO, Dorenberg E, Rikken Lindberg B, Nordhus KC, Jakobsen Ø, Brekken R, Seternes A, Manstad-Hulaas F. Early and mid-term results after endovascular repair of thoracoabdominal aortic aneurysms using the off-the-shelf multibranched t-Branch device: a national multi-center study. SCAND CARDIOVASC J 2024; 58:2335906. [PMID: 38613333 DOI: 10.1080/14017431.2024.2335906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 03/24/2024] [Indexed: 04/14/2024]
Abstract
Objective: The multibranched off-the-shelf Zenith® t-Branch (Cook Medical, Bloomington, IN) device is commonly chosen for endovascular repair of thoracoabdominal aortic aneurysms. The aim of this study was to report early and mid-term outcomes in all patients treated with the t-Branch in Norway; Design and Methods: A retrospective multicenter study with Norwegian centers performing complex endovascular aortic repair was undertaken. T-Branch patients from 2014 to 2020 were included. All postoperative computed tomography angiography images were reviewed, and demographic, anatomical, perioperative and follow-up data were analyzed; Results: Seventy patients were treated in a single-step (n = 55) or staged (n = 15) procedure. Symptomatic presentation was seen in 20 patients, six of which had a contained rupture. Technical success was 87% (n = 59), with failures caused by unsuccessful bridging of target vessels (n = 4), target vessel bleeding (n = 3), persisting type 1c endoleak (n = 1) and t-Branch malrotation (n = 1). 30-day mortality was 9% (n = 6) and was associated with high BMI (p = .038). The spinal cord ischemia rate was 21% (n = 15) and was associated with type II aneurysms (OR 5.4, 95% CI 1.1-26.7, p = .04), smoking (OR 6.0, 95% CI 1.3-27.6, p = .02) and intraoperative blood loss (OR 1.1, 95% CI 1.0-1.3, p = .01). Survival at one, two and three years was 84 ± 4%, 70 ± 6% and 67 ± 6%, respectively. Freedom from aortic-related reinterventions at one, two and three years was 80 ± 5%, 65 ± 7% and 50 ± 8%, respectively; Conclusion: The study showed low early mortality (9%) and satisfactory mid-term survival. Technical success was achieved in acceptable 87% of procedures. The rate of spinal cord ischemia was high, occurring in 21% of patients.
Collapse
Affiliation(s)
- Håvard Ulsaker
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Norwegian National Research Centre for Minimally Invasive and Image-guided Diagnostics and Therapy, St. Olavs Hospital, Trondheim, Norway
| | | | | | - Eric Dorenberg
- Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | | | | | - Øyvind Jakobsen
- Department of Cardiothoracic and Vascular Surgery, University Hospital of North, Norway
| | - Reidar Brekken
- Norwegian National Research Centre for Minimally Invasive and Image-guided Diagnostics and Therapy, St. Olavs Hospital, Trondheim, Norway
- Department of Health Research, SINTEF, Trondheim, Norway
| | - Arne Seternes
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Department of Surgery, St. Olavs University Hospital, Trondheim, Norway
| | - Frode Manstad-Hulaas
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Norwegian National Research Centre for Minimally Invasive and Image-guided Diagnostics and Therapy, St. Olavs Hospital, Trondheim, Norway
- Department of Radiology, St. Olavs University Hospital, Trondheim, Norway
| |
Collapse
|
2
|
Chen Y, Bashir M, Guo J, Piffaretti G, Jubouri M, D'Oria M. Expert-Based Narrative Review on Contemporary Use of an Off-The-Shelf Multibranched Endograft for Endovascular Treatment of Thoracoabdominal Aortic Aneurysms: Device Design, Anatomical Suitability, Technical Tips, Perioperative Care, Clinical Applications, and Real-World Experience. Ann Vasc Surg 2024; 108:98-111. [PMID: 38942377 DOI: 10.1016/j.avsg.2024.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 05/10/2024] [Accepted: 05/15/2024] [Indexed: 06/30/2024]
Abstract
Advanced endovascular techniques, such as fenestrated stent grafts, are nowadays available that permit minimally invasive treatment of complex abdominal aortic aneurysms. However, thoracoabdominal aortic aneurysm patients have anatomic limitations to fenestrated stent-grafts given a large lumen, that is, the gap between the endograft and the inner aortic wall. This has led to the development of branched endovascular aneurysm repair as the ideal option for such patients. The Zenith t-Branch multibranched endograft (Cook Medical, Bloomington, IN), which has been commercially available in Europe to treat thoracoabdominal aortic aneurysm since June 2012, represents a feasible off-the-shelf alternative for treatment of such pathologies, especially in the urgent setting, for patients who cannot wait the time required for manufacturing and delivery of custom-made endografts. The device's anatomical suitability should be considered, especially for female patients with smaller iliofemoral vessels. Several tips may help deal with particularly complex scenarios (such as, for instance, in case of narrow inner aortic lumens or when treating patients with failure of prior endovascular aneurysm repair), and a broad array of techniques and devices must be available to ensure technical and clinical success. Despite promising early outcomes, concerns remain particularly regarding the risk for spinal cord ischemia and further assessment of long-term durability is needed, including the rate of target vessel instability and need for secondary interventions. As the published evidence mainly comes from retrospective registries, it is likely that reported outcomes may suffer from an intrinsic bias as most procedures reported to date have been carried out at high-volume aortic centers. Nonetheless, with the never-ceasing adoption of new and refined techniques, outcomes are expected to ameliorate.
Collapse
Affiliation(s)
- Yonghui Chen
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China.
| | - Mohamad Bashir
- Vascular & Endovascular Surgery, Velindre University NHS Trust, Health & Education Improvement Wales (HEIW), Cardiff, Wales, UK
| | - Jiayin Guo
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Gabriele Piffaretti
- Vascular Surgery Department of Medicine and Surgery, University of Insubria School of Medicine, Varese, Italy
| | - Matti Jubouri
- Vascular & Endovascular Surgery, Velindre University NHS Trust, Health & Education Improvement Wales (HEIW), Cardiff, Wales, UK
| | - Mario D'Oria
- Department of Vascular and Endovascular Surgery, Cardio-Thoraco-Vascular Department, University Hospital of Trieste ASUGI, Trieste, Italy
| |
Collapse
|
3
|
Chen Y, Liu Z, Wang S, D'Oria M, Zhang X, Bi J, Cui D, Dai X. Systematic Review and Meta-analysis of Short-term and Mid-term Outcomes After Use of t-Branch Off-the-shelf Multibranched Endograft for Elective and Urgent Treatment of Thoracoabdominal Aortic Aneurysms. J Endovasc Ther 2023:15266028231220322. [PMID: 38158706 DOI: 10.1177/15266028231220322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
OBJECTIVE To conduct a meta-analysis to assess the safety and efficacy of t-Branch off-the-shelf multibranched endograft for the treatment of thoracoabdominal aortic aneurysm (TAAA). DATA SOURCES PubMed, Embase, and Web of Science. REVIEW METHODS Online databases were searched from June 2012 to March 2023. The data were pooled together using a random-effects model of proportions. The outcomes overall included technical success, spinal cord ischemia, target vessel occlusion, type I or III endoleak, reintervention, early mortality (30-day), and mid-term outcomes. Subgroup meta-analyses and meta-regression were performed to explore variation among studies. RESULTS A total of 15 studies containing 1238 patients were included in the meta-analysis. The overall study quality assessment was found to be moderate to good. The pooled technical success was 97.0% (95% confidence interval [CI]=95.5-98.6, I2=53.01%, 1185/1238 cases, 15 studies). Overall, early mortality was 7.3% (95% CI=4.4-10.1, I2=74.48%, 124/1238 cases, 15 studies). Early spinal cord ischemia was 13.4% (95% CI=9.6-17.2, I2=67.24%, 160/1238 cases, 15 studies), and early type I or III endoleak was 6.0% (95% CI=3.4-8.5, I2=53.71%, 68/1032 cases, 9 studies). Mid-term outcomes showed target vessel occlusion was 4% (95% CI=1.4-6.5, I2=65.18%, 28/528 cases, 10 studies, 5-21.2 months), type I or III endoleak was 4.7% (95% CI=2-7.5, I2=49.74%, 38/512 cases, 10 studies, 5-21.2 months), reintervention was 11.2% (95% CI=8.1-14.3, I2=31.06%, 85/650 cases, 10 studies, 5-21.2 months), and pooled mortality was 13.9% (95% CI=7.2-20.7, I2=76.32%, 84/550 cases, 11 studies, 5-21.2 months). Meta-regression found a significant linear association between higher technical success and earlier publication year (p=0.014) and studies with anatomic inclusion criteria (p=0.037). Urgent patients (p=0.021) and later publication year (p=0.048) were significantly associated with higher early mortality. CONCLUSION The use of the off-the-shelf t-Branch multibranched endograft for elective or urgent endovascular TAAA repair is associated with high technical success rates and proved to be safe and effective at early and mid-term follow-up. However, the heterogeneity between the included studies is high, and prospective, randomized studies along with future larger studies with long-term follow-up are needed. CLINICAL IMPACT The Zenith t-Branch (Cook Medical, Bloomington, Ind) was approved as a commercially available device in Europe in June 2012. Although a decade has past, the outcomes of t-Branch have rarely been synthesized at the global level. This meta-analysis included 15 studies containing 1238 patients. The meta-analyses included technical success, major adverse events, reintervention, early mortality, and mid-term outcomes. The outcome was very meaningful and representative for the use of t-Branch. It is helpful for endovascular surgeons to make decisions on the treatment of TAAA patients.
Collapse
Affiliation(s)
- Yonghui Chen
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Zongwei Liu
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Shuaishuai Wang
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, Cardio-thoraco-vascular Department, University Hospital of Trieste Azienda Sanitaria Universitaria Giuliano Isontina, Trieste, Italy
| | - Xiaoxing Zhang
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Jiaxue Bi
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Dongsheng Cui
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| | - Xiangchen Dai
- Department of Vascular Surgery, Tianjin Medical University General Hospital, Tianjin, China
| |
Collapse
|
4
|
Khoury MK, Lancaster E, Eagleton MJ, Gasper WJ. Update of T-branch use from the US Aortic Research Consortium. THE JOURNAL OF CARDIOVASCULAR SURGERY 2023; 64:470-474. [PMID: 37389548 DOI: 10.23736/s0021-9509.23.12737-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/01/2023]
Abstract
Aortic endograft evolution has altered our approach to treating patients with both standard and complex aortic disease. In particular, fenestrated and branched aortic endografts have allowed for the expansion of therapy to include those patients with extensive thoracoabdominal aortic aneurysms (TAAAs). The fenestrations and branches allow for the aortic endografts to achieve a seal in the proximal and distal aspects of the aorto-iliac tree, to exclude the aneurysm, while maintaining perfusion to the renal and visceral vessels. Historically, many of the grafts used for this purpose are custom made devices designed for a specific patient based on their preoperative computed tomography imaging. One downside to this approach is the time it takes to construct these grafts. Given this, much effort has been directed towards developing "off-the-shelf" grafts which may be applicable to many patients in an immediate-need bases. The Zenith T-Branch device offers an off-the-shelf graft with four directional branches. Its utilization is not applicable to all patients, but can be applied to many patients with TAAAs. Large reported series on outcomes for these devices is limited to centers in Europe as well as within the United States Aortic Research Consortium. While early outcomes appear excellent, long-term outcomes related to aneurysm exclusion, branch patency, and freedom from reintervention are needed and will be forthcoming.
Collapse
Affiliation(s)
- Mitri K Khoury
- Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Elizabeth Lancaster
- Division of Vascular and Endovascular Surgery, University of California San Francisco, San Francisco, CA, USA
| | - Matthew J Eagleton
- Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA, USA -
| | - Warren J Gasper
- Division of Vascular and Endovascular Surgery, University of California San Francisco, San Francisco, CA, USA
| |
Collapse
|
5
|
Bilman V, Rinaldi E, Loschi D, Sheick-Yousif B, Melissano G. Suitability of current off-the-shelf devices for endovascular TAAA repair: a systematic review. THE JOURNAL OF CARDIOVASCULAR SURGERY 2023; 64:459-469. [PMID: 37199677 DOI: 10.23736/s0021-9509.23.12704-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
INTRODUCTION The aim of the present study is to perform a systematic review of published papers regarding the suitability of the current off-the-shelf (OTS) devices for endovascular thoracoabdominal aortic aneurysm (TAAA) repair. EVIDENCE ACQUISITION A systematic review of the MEDLINE database via PubMed was performed in March 2023. All studies reporting the outcomes of the three currently available OTS stent-grafts: the Zenith t-Branch (Cook Medical, Bloomington, IN, USA), the Gore Excluder thoracoabdominal branch endoprosthesis (TAMBE; W.L. Gore & Associates, Flagstaff, AZ, USA) and the E-nside Multibranch Stent-Graft System (Artivion, Kennesaw, GA, USA), were retrieved and further analyzed. The main endpoints were technical success, reintervention rate, and primary branch patency. Theoretical feasibility studies of these OTS devices were also included and separately analyzed. EVIDENCE SYNTHESIS A total of 19 studies were published between 2014 and 2023. Thirteen clinical studies and six theoretical feasibility studies were included. Eleven studies reported the clinical outcomes of the t-Branch stent-graft, one detailed the observational results of the use of the E-nside endoprosthesis, and one described the TAMBE stent-graft results. The following data primarily involve the t-Branch device outcomes. A total of 1131 patients that underwent aneurysm repair using an OTS stent-graft were identified. Among those, 1002, 116 and 13 patients received a t-Branch, E-nside, and TAMBE stent-grafts, respectively. A total of 767 (67.8%) were men, with a mean age of 71.6±7.4 years old, and a mean Body Mass Index (BMI) of 26.3±3.8 kg/m2. Technical success ranged from 64% to 100%. A total of 4172 target visceral vessels (TVV) were planned for bridging, with a success rate ranging from 92 to 100%. The total of early and late reinterventions reported were 64 and 48, respectively, mainly due to endoleaks and visceral branch occlusions. Among the theoretical feasibility studies, six described the feasibility of the t-Branch device in a total of 661 patients, two described the E-nside and the TAMBE devices feasibility comprising 351 patients for each stent-graft. The overall feasibility of the t-Branch device varied from 39% to 88%, the E-nside from 43% to 75%, and the TAMBE stent-graft ranged from 33% to 94%. CONCLUSIONS This systematic review demonstrated a good suitability for the use of OTS endografts for the treatment of TAAA.
Collapse
Affiliation(s)
- Victor Bilman
- Department of Vascular Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Enrico Rinaldi
- Department of Vascular Surgery, Vita-Salute San Raffaele University School of Medicine, IRCCS San Raffaele Hospital, Milan, Italy
| | - Diletta Loschi
- Department of Vascular Surgery, Vita-Salute San Raffaele University School of Medicine, IRCCS San Raffaele Hospital, Milan, Italy
| | - Basheer Sheick-Yousif
- Department of Vascular Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Germano Melissano
- Department of Vascular Surgery, Vita-Salute San Raffaele University School of Medicine, IRCCS San Raffaele Hospital, Milan, Italy -
| |
Collapse
|
6
|
Grandi A, Melloni A, D'Oria M, Lepidi S, Bonardelli S, Kölbel T, Bertoglio L. Emergent endovascular treatment options for thoracoabdominal aortic aneurysm. Semin Vasc Surg 2023; 36:174-188. [PMID: 37330232 DOI: 10.1053/j.semvascsurg.2023.04.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/04/2023] [Accepted: 04/04/2023] [Indexed: 06/19/2023]
Abstract
For a long time, parallel grafting, physician-modified endografts, and, more recently, in situ fenestration were the only go-to endovascular options for ruptured thoracoabdominal aortic aneurysm, offered mixed results, and depended mainly on the operator's and center's experience. As custom-made devices have become an established endovascular treatment option for elective thoracoabdominal aortic aneurysm, they are not a viable option in the emergency setting, as endograft production can take up to 4 months. The development of off-the-shelf (OTS) multibranched devices with a standardized configuration has allowed the treatment of ruptured thoracoabdominal aortic aneurysm with emergent branched endovascular procedures. The Zenith t-Branch device (Cook Medical) was the first readily available graft outside the United States to receive the CE mark (in 2012) and is currently the most studied device for those indications. A new device, the E-nside thoracoabdominal branch endoprosthesis OTS multibranched endograft (Artivion), has been made commercially available, and the GORE EXCLUDER thoracoabdominal branch endoprosthesis OTS multibranched endograft (W. L. Gore and Associates) is expected to be released in 2023. Due to the lack of guidelines on ruptured thoracoabdominal aortic aneurysm, this review summarizes the available treatment options (ie, parallel grafts, physician-modified endografts, in situ fenestrations, and OTS multibranched devices), compares the indications and contraindications, and points out the evidence gaps that should be filled in the next decade.
Collapse
Affiliation(s)
- Alessandro Grandi
- Department of Vascular Medicine, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Andrea Melloni
- Division of Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia School of Medicine, ASST Spedali Civili of Brescia, Brescia, Italy
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, Cardiovascular Department, University Hospital of Trieste Azienda sanitaria universitaria Giuliano Isontina, Trieste, Italy
| | - Sandro Lepidi
- Division of Vascular and Endovascular Surgery, Cardiovascular Department, University Hospital of Trieste Azienda sanitaria universitaria Giuliano Isontina, Trieste, Italy
| | - Stefano Bonardelli
- Division of Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia School of Medicine, ASST Spedali Civili of Brescia, Brescia, Italy
| | - Tilo Kölbel
- Department of Vascular Medicine, University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Luca Bertoglio
- Division of Vascular Surgery, Department of Clinical and Experimental Sciences, University of Brescia School of Medicine, ASST Spedali Civili of Brescia, Brescia, Italy.
| |
Collapse
|
7
|
Zacà S, Patruno I, Pulli R, Angiletta D. Endovascular repair using parallel grafts to treat a suprarenal pancreatitis-related abdominal aortic pseudoaneurysm. Catheter Cardiovasc Interv 2023; 101:888-891. [PMID: 36883951 DOI: 10.1002/ccd.30624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 01/17/2023] [Accepted: 02/27/2023] [Indexed: 03/09/2023]
Abstract
Arterial pseudoaneurysms represent an uncommon complication of acute pancreatic inflammation or chronic pancreatitis. We describe a contained rupture of a suprarenal abdominal aortic pseudoaneurysm. An aorto-uni-iliac stent-graft was adopted as the aortic main body and was combined with two chimneys and two periscope stents for celiac/superior mesenteric artery and renal arteries, respectively. The procedure was complicated by the entrapment of the celiac sheath into the barbs of the aortic stent-graft and the attempts to remove the sheath resulted in an upward migration of the stent-grafts. A bail-out endovascular procedure was used to reline the stent-grafts and the pseudoaneurysmal sac was embolized with coils.
Collapse
Affiliation(s)
- Sergio Zacà
- Vascular and Endovascular Surgery-Department of Emergency and Organs Transplantation, "Aldo Moro" University of Bari School of Medicine, Bari, Italy
| | - Isabella Patruno
- Vascular and Endovascular Surgery-Department of Emergency and Organs Transplantation, "Aldo Moro" University of Bari School of Medicine, Bari, Italy
| | - Raffaele Pulli
- Department of Vascular Surgery, Careggi University Hospital, Florence, Italy
| | - Domenico Angiletta
- Vascular and Endovascular Surgery-Department of Emergency and Organs Transplantation, "Aldo Moro" University of Bari School of Medicine, Bari, Italy
| |
Collapse
|
8
|
Dias-Neto M, Tenorio ER, Lima GBB, Baghbani-Oskouei A, Saqib N, Mendes BC, Mirza AK, Oderich GS. Outcomes of low- and standard-profile fenestrated and branched stent grafts for treatment of complex abdominal and thoracoabdominal aortic aneurysms. J Vasc Surg 2022; 76:1160-1169.e1. [PMID: 35810953 DOI: 10.1016/j.jvs.2022.05.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 04/30/2022] [Accepted: 05/02/2022] [Indexed: 11/16/2022]
Abstract
OBJECTIVE We compared the outcomes of fenestrated-branched (FB) endovascular abdominal aortic aneurysm repair (EVAR) using low-profile (LP) and standard-profile (SP) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs) and thoracoabdominal aortic aneurysms (TAAAs). METHODS We reviewed the clinical data of 466 consecutive patients (70% male; mean age, 74 ± 8 years) enrolled in a prospective nonrandomized study to investigate FB-EVAR for the treatment of CAAAs and TAAAs (2013-2021). The endpoints compared between the patients treated with LP (18F-20F) and SP (20F-22F) devices included procedural metrics, access-related complications, major adverse events (MAE), patient survival, freedom from secondary intervention, thromboembolic events, stent graft integrity issues, aneurysm sac enlargement, and the rate of sac shrinkage. RESULTS Of the 466 aneurysms treated by FB-EVAR, 138 were CAAAs and 141 were extent IV and 187 extent I to III TAAAs, with a mean number of 3.9 ± 0.5 vessels stented per patient. LP devices had been used in 239 patients (51%) and SP devices in 227 patients (49%). LP devices had been used more frequently for chronic dissections (12% vs 7%; P = .041) and with preloaded systems (77% vs 65%; P = .005) and bilateral percutaneous femoral access (83% vs 74%; P = .020) and less frequently with upper extremity access (67% vs 88%; P < .001) and iliac conduits (2% vs 6%; P = .020). The patients treated using LP devices had experienced similar technical success (96% vs 97%; P = .527), with a shorter total operating time (225 ± 81 minutes vs 243 ± 78 minutes; P = .018), lower radiation exposure (median, 0.93 Gy; interquartile range [IQR], 0.94; vs median, 1.01 Gy; IQR, 0.91 Gy; P < .001), and less use of contrast (median, 135 mL; IQR, 68 mL; vs median, 144 mL; IQR, 80 mL; P = .008). No differences were found in the rates of iliofemoral access complications between the LP and SP device groups (1.3% vs 3.5%; P = .107). At 30 days, 5 patients had died (1%) and MAEs had occurred in 89 patients (19%), with no differences between the two groups. The mean follow-up was 28 months (95% confidence interval, 25-30 months). At 4 years, the patients treated with LP devices had had similar freedom from all-cause mortality (69% ± 6% vs 68% ± 4%; P = .199), freedom from aortic-related mortality (97% ± 1% vs 98% ± 1%; P = .488), freedom from any secondary intervention (65% ± 6% vs 70% ± 4%; P = .433), freedom from thromboembolic events (98% ± 1% vs 99% ± 1%; P = .364) and aneurysm sac enlargement (93% ± 3% vs 91% ± 3%; P = .293). However, the LP group had had less freedom from any integrity-related issues (92% ± 5% vs 100%; P < .001). The cumulative risk of sac shrinkage was greater for patients treated with LP devices (adjusted hazard ratio, 2.040; 95% confidence interval, 1.516-2.744; P < .001). CONCLUSIONS FB-EVAR was performed with low rates of mortality and MAEs, irrespective of the device profile. However, the procedures performed with LP devices had had less need for iliac conduits and had had better procedural metrics. The use of LP devices resulted in higher rates of sac shrinkage. However, the results on stent graft integrity require future investigation.
Collapse
Affiliation(s)
- Marina Dias-Neto
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX
| | - Emanuel R Tenorio
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX
| | - Guilherme B Barbosa Lima
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX
| | - Aidin Baghbani-Oskouei
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX
| | - Naveed Saqib
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX
| | - Bernardo C Mendes
- Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN
| | - Aleem K Mirza
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX
| | - Gustavo S Oderich
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX.
| |
Collapse
|
9
|
Tenorio ER, Oderich GS, Kölbel T, Gargiulo M, Timaran CH, Bertoglio L, Modarai B, Jama K, Eleshra A, Lima GBB, Scott C, Chiesa R, Jakimowicz T. Outcomes of off-the-shelf multibranched stent grafts with intentional occlusion of directional branches using endovascular plugs during endovascular repair of complex aortic aneurysms. J Vasc Surg 2022; 75:1142-1150.e4. [PMID: 34748899 DOI: 10.1016/j.jvs.2021.09.050] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/24/2021] [Indexed: 01/10/2023]
Abstract
OBJECTIVE To evaluate the technique and outcomes of intentional occlusion of directional branches (DBs) using endovascular plugs during branched endovascular aortic repair using off-the-shelf Zenith t-Branch thoracoabdominal (TAAA) stent grafts. METHODS We reviewed the clinical data and outcomes of all consecutive patients treated by branched endovascular aortic repair using off-the-shelf Zenith t-Branch TAAA stent-graft (Cook Medical, Bloomington, Ind) in seven academic centers from 2013 to 2019. All patients had at least one DB intentionally occluded using extension of the branch with balloon or self-expandable covered stent, followed by placement of endovascular plugs. Intentional occlusion was indicated in patients with variations in the normal four-vessel renal-mesenteric anatomy, pre-existing dialysis, or in those who failed catheterization of a target vessel. End points were 30-day/in-hospital mortality, major adverse events, secondary interventions, target artery (TA) patency, TA instability, and patient survival. RESULTS There were 100 patients, 65 male and 35 female, with median age of 71 years (interquartile range [IQR], 66-75 years). Of these, 31 patients (31%) had urgent/emergent operations for symptomatic/contained ruptured aneurysms. The median aneurysm diameter was 72 mm (IQR, 61-85 mm). A total of 290 renal-mesenteric arteries were incorporated with a median of three (IQR, 3-3) vessels/patient. Indications for DB occlusion were less than four suitable renal-mesenteric targets in 84 patients or pre-existing dialysis and inability to catheterize a target vessel in eight patients each. There were 110 DBs occluded by vascular plugs, including 48 celiac axis, one superior mesenteric artery, and 61 renal DBs. Thirty-day/in-hospital mortality was 10%, including 9% for elective and 13% for urgent/emergent procedures. Major adverse events occurred in 44 patients (44%), including acute kidney injury in 19 patients (19%), estimated blood loss >1 L in 12 patients (12%), respiratory failure and new onset dialysis in six patients (6%) each, bowel ischemia in five patients (5%), and myocardial infarction and paraplegia in two patients (2%) each. The median follow-up was 5 months (range, 1-13 months). Eighteen patients (18%) required secondary interventions, none for problems related to the occluded DB. There were no endoleaks related to the occluded DB. At 2 years, primary and secondary patency and freedom from TA instability were 93% ± 3%, 97% ± 2%, and 91% ± 4%, respectively. Freedom from secondary interventions and patient survival were 75% ± 6% and 63% ± 7%, respectively. CONCLUSIONS Intentional occlusion of DBs using endovascular plugs allows versatile use of a four-vessel off-the-shelf multi-branched TAAA stent graft in patients with variations in the normal renal and mesenteric anatomy or when technical difficulties prevent successful target vessel stenting. There were no endoleaks or secondary interventions associated with the occluded DB.
Collapse
Affiliation(s)
- Emanuel R Tenorio
- Department of Cardiothoracic and Vascular Surgery, Advanced Aortic Research Program at the University of Texas Health Science Center at Houston, McGovern Medical School, Houston, Tex
| | - Gustavo S Oderich
- Department of Cardiothoracic and Vascular Surgery, Advanced Aortic Research Program at the University of Texas Health Science Center at Houston, McGovern Medical School, Houston, Tex.
| | - Tilo Kölbel
- German Aortic Center, Department of Vascular Medicine, University Heart Center Hamburg, Hamburg, Germany
| | - Mauro Gargiulo
- Department of Vascular Surgery, University of Bologna, University Hospital Policlinico S. Orsola, Bologna, Italy
| | - Carlos H Timaran
- Division of Vascular and Endovascular Surgery, University of Texas Southwestern, Dallas, Tex
| | - Luca Bertoglio
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milano, Italy
| | - Bijan Modarai
- Guy's and St Thomas' NHS Foundation Trust and King's College London, King's Health Partners, London, United Kingdom
| | - Katarzyna Jama
- Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, Warszawa, Poland
| | - Ahmed Eleshra
- German Aortic Center, Department of Vascular Medicine, University Heart Center Hamburg, Hamburg, Germany
| | - Guilherme B B Lima
- Department of Cardiothoracic and Vascular Surgery, Advanced Aortic Research Program at the University of Texas Health Science Center at Houston, McGovern Medical School, Houston, Tex
| | - Carla Scott
- Division of Vascular and Endovascular Surgery, University of Texas Southwestern, Dallas, Tex
| | - Roberto Chiesa
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milano, Italy
| | - Tomasz Jakimowicz
- Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, Warszawa, Poland
| | | |
Collapse
|
10
|
Expanding the applicability of the off-the-shelf multibranched thoracoabdominal aortic device beyond the anatomic boundaries. J Vasc Surg 2022; 75:1151. [DOI: 10.1016/j.jvs.2021.10.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 10/27/2021] [Indexed: 11/18/2022]
|
11
|
Outcomes of multibranched off-the-shelf stent graft in elective and urgent/emergent repair of complex aortic aneurysms with narrow internal aortic lumen. J Vasc Surg 2022; 76:326-334. [PMID: 35314297 DOI: 10.1016/j.jvs.2022.03.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 03/06/2022] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To assess the outcomes of Cook t-Branch off-the-shelf multibranched stent graft (Cook Medical, Bloomington, IN, USA) in the treatment of complex aortic aneurysms with narrow internal aortic lumen. METHODS Between 2016 and 2020, 48 patients (mean age 73 years) underwent elective or urgent/emergent Cook t-Branch implantation for thoracoabdominal or para/juxtarenal aortic aneurysms in 2 Italian vascular centers. Among these, 20 patients presented a paravisceral/pararenal luminal diameter < 25 mm. Major clinical and radiological outcomes of patients with narrow aortic lumen were compared with patients with larger lumen in a multicenter, non-randomized, retrospective fashion. RESULTS The in-hospital mortality was 10% (5% in the elective setting). Spinal cord ischemia occurred in 6% of the cases. During a mean follow-up of 18 months (range 1 - 63), late t-Branch procedure-related mortality and the need for re-intervention was 0% and 12%, respectively. Comparing the outcomes of patients with large internal aortic lumen (Group 1) with patients with small lumen (Group 2), no significant difference was found regarding fluoroscopy time (p = 0.3), technical success (p = 1), early (p = 0.4) and late (p = 1) mortality, spinal cord ischemia (p = 0.2), bowel ischemia (p = 0.5), renal (p = 0.7), cardiac (p = 1), and respiratory complications (p = 1), re-intervention rate (p = 1), and primary patency rate of stented target vessels (p = 1). CONCLUSION The use of the Cook t-Branch in our experience was safe and effective in the treatment of complex aortic aneurysms regardless the caliber of the aortic lumen. With all the limitations of a small sample size, this approach has demonstrated to be feasible also when maneuverability is reduced, with low mortality and morbidity, and acceptable re-intervention need. Perioperative mortality remains closely related to clinical presentation. Large-scale studies are needed to confirm these results.
Collapse
|
12
|
Voigt HC, Koeppel T. Reversed and Antegrade Iliac Side Branch Stentgraft as an Alternative or Rescue Maneuver in Complex (Thoraco)Abdominal Endovascular Aortic Repair to Preserve Renal Perfusion. J Endovasc Ther 2022; 30:347-354. [DOI: 10.1177/15266028221082009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose To describe a technique that can preserve renal perfusion in failed bridging stent implantation of renal arteries or as intentional procedure in emergency cases, when the (thoraco)abdominal aneurysm anatomy does not meet the criteria for instructions for use of an “off-the-shelf” graft. The technique is based on reversed or antegrade integration of a standard iliac side branch graft into the aortic stentgraft system, which allows cannulation of (accessory) renal vessels. Technique A standard iliac side branch prosthesis is deployed and re-sheathed in reversed direction on the back table. The endograft is then implanted in the unibody in analogy to an iliac limb. The iliac side branch is cannulated followed by target vessel cannulation and covered bridging stents are deployed for completion. Furthermore, an iliac side branch prothesis can also be used to preserve relevant accessory renal arteries, when implanted in delivered antegrade loading position. Conclusion The use of a reversed and antegrade iliac side branch technique to revascularize renal vessels is feasible and safe in selected patients. This technique may also allow to extend the range of an “offthe- shelf” (multibranch) stentgraft, when immediate treatment is required.
Collapse
Affiliation(s)
- Hans-Christian Voigt
- Department of Vascular and Endovascular Surgery, Asklepios Clinic St. Georg, Hamburg, Germany
| | - Thomas Koeppel
- Department of Vascular and Endovascular Surgery, Asklepios Clinic St. Georg, Hamburg, Germany
| |
Collapse
|
13
|
Gallitto E, Faggioli G, Spath P, Pini R, Mascoli C, Logiacco A, Gargiulo M. Urgent endovascular repair of thoracoabdominal aneurysms using an off-the-shelf multibranched endograft. Eur J Cardiothorac Surg 2021; 61:1087-1096. [PMID: 34964451 DOI: 10.1093/ejcts/ezab553] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 10/17/2021] [Accepted: 11/01/2021] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES Our goal was to report outcomes of the endovascular repair of urgent thoracoabdominal aortic aneurysms (TAAAs) using the Cook Zenith t-Branch off-the-shelf multibranched endograft. METHODS Between 2010 and 2020, we collected patients with TAAAs who received an urgent endovascular repair using the Cook Zenith t-Branch (had a rupture, symptoms or diameter >80 mm). Thirty-day mortality, spinal cord ischaemia (SCI) and clinical success were assessed as early outcomes. Freedom from reintervention, target visceral vessel patency and survival were considered during follow-up. RESULTS Sixty-five cases were managed using the Cook Zenith t-Branch for 27 (42%) TAAA ruptures, 8 (12%) symptomatic TAAAs and 30 (46%) asymptomatic TAAAs with a diameter >80 mm. Crawford's extent I-II-III and IV were noted in 54 (83%) and 11 (17%), respectively. Eleven (17%) patients had SCI with 3 (5%) cases of permanent paraplegia. Postoperative dialysis (P = 0.04) and ruptured TAAAs (P = 0.05) were associated with SCI. Sixteen (25%) patients had reinterventions within the first 30 days postoperatively. The 30-day mortality was 14% (9). Ruptured TAAAs (P = 0.05) and technical failures (P = 0.01) were correlated with in-hospital mortality. Clinical success was 78% (51 patients). The mean follow-up was 18 ± 14 months. Survival at 24 months was 47% with no late TAAA-related deaths. Patients with ruptured TAAAs had lower survival than those who did not have ruptured TAAAs (52% vs 60% at 1 year; P = 0.05). Target visceral vessel patency and freedom from reintervention at 24 months were 89% and 60%, respectively. CONCLUSIONS An off-the-shelf multibranched endograft is safe and effective for treating urgent TAAAs. Postoperative SCI and 30-day mortality are satisfactory for this challenging clinical scenario. The early reintervention rate is not negligible. Midterm survival is low, especially in patients with a ruptured TAAA; therefore, accurate patient selection is mandatory.
Collapse
Affiliation(s)
- Enrico Gallitto
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| | - Gianluca Faggioli
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| | - Paolo Spath
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| | - Rodolfo Pini
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| | - Chiara Mascoli
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| | - Antonino Logiacco
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| | - Mauro Gargiulo
- Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, IRCCS Sant'Orsola-Malpighi, 9th Massarenti Street, 40100, Bologna, Italy
| |
Collapse
|
14
|
Mazzaccaro D, Avishay D, Nano G. Factors Affecting the Visceral Suitability of a Multibranched off-the-Shelf Endograft for the Treatment of Thoraco-Abdominal Aortic Aneurysms. Ann Vasc Surg 2021; 81:113-120. [PMID: 34743010 DOI: 10.1016/j.avsg.2021.08.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 08/16/2021] [Accepted: 08/29/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND To assess the factors affecting visceral suitability of the use of the Zenith T-branchTM system in a group of patients with thoraco-adbominal aortic aneurysms (TAAAs). METHODS Computer tomography angiography (CTA) of patients who presented a TAAA from 01/2015 to 12/2019 were retrospectively examined. Multi-Planar Reconstructions were performed on CTA images to assess the anatomic suitability of the Zenith T-branch in the visceral district. In particular, the branch deviation angle (BDA), and the branch-length were computed for each target vessel. RESULTS Fifty-four CTA were examined. In 33.3% of these patients the presence of either a common origin of the superior mesenteric artery and the celiac trunk, or the diameter of 1 or more visceral/renal artery limited the visceral suitability of the device. All patients except 1 (97.9%) fitted the BDA criterion when the graft was placed in a position in which the BDA for the SMA was 5 degrees to the left. The branch-length criteria was met in all patients, except for 1 (97.9%), when the graft was placed in the center of the aorta. The eccentrical placement of the endograft decreased the suitability to 93.7%. CONCLUSIONS The Zenith T-branch system can be suitable in the visceral district for about 67% of patients. The target artery diameter was the most limiting criterion. The central location of the graft within the aortic lumen significantly affected the branch-length distance criteria.
Collapse
Affiliation(s)
- Daniela Mazzaccaro
- Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy.
| | - Dor Avishay
- Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy
| | - Giovanni Nano
- Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy; Department of Biomedical Sciences for Health, University of Milan, Milan, Italy
| |
Collapse
|
15
|
Tenorio ER, Dias-Neto MF, Lima GBB, Estrera AL, Oderich GS. Endovascular repair for thoracoabdominal aortic aneurysms: current status and future challenges. Ann Cardiothorac Surg 2021; 10:744-767. [PMID: 34926178 PMCID: PMC8640886 DOI: 10.21037/acs-2021-taes-24] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 10/26/2021] [Indexed: 12/23/2022]
Abstract
Open surgical repair has been the gold standard for treatment of thoracoabdominal aortic aneurysms (TAAA). Currently, open surgical repair has been reserved mostly for young and fit patients with connective tissue disorders, using separate branch vessel reconstructions instead of 'island' patches, and distal perfusion instead of a 'clamp and go' technique. Endovascular repair has gained widespread acceptance because of its potential to significantly decrease morbidity and mortality. Several large aortic centers have developed dedicated clinical programs to advance techniques of fenestrated-branched endovascular aortic repair (FB-EVAR) using patient-specific and off-the-shelf devices, which offers a less-invasive alternative to open repair. Although FB-EVAR was initially considered an option for older and frail patients, many centers have expanded its indications to any patient with suitable anatomy and no evidence of connective tissue disorders, independent of their clinical risk. In this article, we review current techniques and outcomes of endovascular TAAA repair.
Collapse
Affiliation(s)
- Emanuel R Tenorio
- Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| | - Marina F Dias-Neto
- Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| | - Guilherme Baumgardt Barbosa Lima
- Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| | - Anthony L Estrera
- Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| | - Gustavo S Oderich
- Department of Cardiothoracic & Vascular Surgery, Advanced Aortic Research Program, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| |
Collapse
|
16
|
Bertoglio L, Grandi A, Carta N, Cambiaghi T, Bilman V, Melissano G, Chiesa R. Comparison of anatomic feasibility of three different multibranched off-the-shelf stent-grafts designed for thoracoabdominal aortic aneurysms. J Vasc Surg 2021; 74:1472-1482.e4. [PMID: 34023432 DOI: 10.1016/j.jvs.2021.04.066] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 04/23/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE We compared the theoretical anatomic feasibility of endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs) with three off-the-shelf multibranched stent-grafts: t-Branch (Zenith t-Branch; Cook Medical, Bloomington, Ind), Gore Excluder thoracoabdominal branch endoprosthesis (TAMBE; W. L. Gore & Associates, Flagstaff, Ariz), and E-nside (E-nside multibranch stent graft system; Jotec GmbH, Hechingen, Germany). METHODS Computed tomography scans of patients with degenerative TAAAs treated from 2007 to 2019 were reviewed, and the anatomic feasibility of the multibranched stent-grafts was assessed according to the manufacturer's instructions for use. The anatomic factors determining the overall feasibility were divided into access feasibility, aortic feasibility, and visceral vessel feasibility. RESULTS Degenerative TAAAs in 268 patients were analyzed. The overall feasibility did not differ significantly (TAMBE, 33%; t-Branch, 39%; E-nside, 43%; P = .271). Access, aortic, and visceral vessel feasibility alone excluded 18% to 22%, 35% to 49% and 21% to 26% of the patients respectively. The only significant difference between the devices was in aortic feasibility (P = .005), which was more frequently limited by the proximal aortic neck diameter in the TAMBE cohort and the inner visceral aortic diameter in the t-Branch cohort. The overall treatment feasibility using any of the three devices would have been 58%. CONCLUSIONS The new investigational off-the-shelf multibranched stent-grafts did not significantly improve the theoretical applicability in an extensive cohort of patients with TAAAs. Improvements are warranted to increase their overall feasibility.
Collapse
Affiliation(s)
- Luca Bertoglio
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy.
| | - Alessandro Grandi
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Niccolò Carta
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Tommaso Cambiaghi
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, Tex
| | - Victor Bilman
- Cirurgia Vascular e Endovascular, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Germano Melissano
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Roberto Chiesa
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| |
Collapse
|
17
|
Youssef M, Gunaseelan M. A Branch-to-Branch Through-and-Through Wire Technique to Redirect a Branch Malposition in Multibranched Endovascular Aortic Aneurysm Repair. J Endovasc Ther 2021; 28:682-686. [PMID: 33998351 DOI: 10.1177/15266028211016434] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To describe a novel technique to redirect a malrotated branch when treating a symptomatic juxtarenal aortic aneurysm using an off-the-shelf multibranched endograft. TECHNIQUE A 75-year-old patient was admitted because of a symptomatic juxtarenal aortic aneurysm with a maximum diameter of 9.2 cm. The aneurysm showed no infrarenal neck. Because of his comorbidities, an endovascular repair using off-the-shelf multibranched endograft was considered as urgent procedure. During the deployment, the devise malrotated clockwise. The incorporation of the renal branches was performed successfully; however, the superior mesenteric artery (SMA) branch was malpositioned, so that the SMA could not be cannulated. Both celiac and SMA branches were simultaneously cannulated and snared outside of the endograft redirecting the malrotated SMA branch (a branch-to-branch through-and-through wire technique). Leaving the through-and-through wire in situ, the SMA could be intubated using parallel wire through the SMA branch. The final angiogram showed a good perfusion of the renovisceral vessels. The aneurysm was completely excluded. The patient was discharged into a rehabilitation facility 8 days later without complications. The 12-month follow-up period was uneventful. CONCLUSION A branch-to-branch through-and-through wire technique for branch repositioning is feasible and may present a bailout tool.
Collapse
Affiliation(s)
- Marwan Youssef
- Department of Vascular and Endovascular Surgery, Academic Asklepios Hospital Nord-Heidberg, Hamburg, Germany
| | - Meera Gunaseelan
- Department of Vascular and Endovascular Surgery, Academic Asklepios Hospital Nord-Heidberg, Hamburg, Germany
| |
Collapse
|
18
|
Edman NI, Schanzer A, Crawford A, Oderich GS, Farber MA, Schneider DB, Timaran CH, Beck AW, Eagleton M, Sweet MP. Sex-related outcomes after fenestrated-branched endovascular aneurysm repair for thoracoabdominal aortic aneurysms in the U.S. Fenestrated and Branched Aortic Research Consortium. J Vasc Surg 2021; 74:861-870. [PMID: 33775747 DOI: 10.1016/j.jvs.2021.02.046] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 02/28/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE Fenestrated-branched endovascular aneurysm repair (FBEVAR) has expanded the treatment of patients with thoracoabdominal aortic aneurysms (TAAAs). Previous studies have demonstrated that women are less likely to be treated with standard infrarenal endovascular aneurysm repair because of anatomic ineligibility and experience greater mortality after both infrarenal and thoracic aortic aneurysm repair. The purpose of the present study was to describe the sex-related outcomes after FBEVAR for treatment of TAAAs. METHODS The data from 886 patients with extent I to IV TAAAs (excluding pararenal or juxtarenal aneurysms), enrolled in eight prospective, physician-sponsored, investigational device exemption studies from 2013 to 2019, were analyzed. All data were collected prospectively, audited and adjudicated by clinical events committees and/or data safety monitoring boards, and subject to Food and Drug Administration oversight. All the patients had been treated with Cook-manufactured patient-specific FBEVAR devices or the Cook t-Branch off-the-shelf device (Cook Medical, Brisbane, Australia). RESULTS Of the 886 patients who underwent FBEVAR, 288 (33%) were women. The women had more extensive aneurysms and a greater prevalence of diabetes (33% vs 26%; P = .043) but a lower prevalence of coronary artery disease (33% vs 52%; P < .0001) and previous infrarenal endovascular aneurysm repair (7.6% vs 16%; P < .001). The women had required a longer operative time from incision to surgery end (5.0 ± 1.8 hours vs 4.6 ± 1.7 hours; P < .001), experienced lower technical success (93% vs 98%; P = .002), and were less likely to be discharged to home (72% vs 83%; P = .009). Despite the smaller access vessels, the women did not have an increased incidence of access site complications. Also, the 30-day outcomes were broadly similar between the sexes. At 1 year, no differences were found between the women and men in freedom from type I or III endoleak (91.4% vs 92.0%; P = .64), freedom from reintervention (81.7% vs 85.3%; P = .10), target vessel instability (87.5% vs 89.2%; P = .31), and survival (89.6% vs 91.7%; P = .26). The women had a greater incidence of postoperative sac expansion (12% vs 6.5%; P = .006). Multivariable modeling adjusted for age, aneurysm extent, aneurysm size, urgent procedure, and renal function showed that patient sex was not an independent predictor of survival (hazard ratio, 0.83; 95% confidence interval, 0.50-1.37; P = .46). CONCLUSIONS Women undergoing FBEVAR demonstrated metrics of increased complexity and had a lower level of technical success, especially those with extensive aneurysms. Compared with the men, the women had similar 30-day mortality and 1-year outcomes, with the exception of an increased incidence of sac expansion. These data have demonstrated that FBEVAR is safe and effective for women and men but that further efforts to improve outcome parity are indicated.
Collapse
Affiliation(s)
- Natasha I Edman
- Division of Vascular Surgery, Department of Surgery, University of Washington Medical Center, Seattle, Wash; Medical Scientist Training Program, University of Washington, Seattle, Wash
| | - Andres Schanzer
- Division of Vascular Surgery, University of Massachusetts, Worcester, Mass
| | - Allison Crawford
- Division of Vascular Surgery, University of Massachusetts, Worcester, Mass
| | - Gustavo S Oderich
- Advanced Endovascular Aortic Program, Division of Vascular and Endovascular Surgery, University of Texas Health Science Center at Houston, McGovern Medical School, Houston, Tex
| | - Mark A Farber
- Division of Vascular Surgery, Department of Surgery, University of North Carolina, Chapel Hill, NC
| | - Darren B Schneider
- Division of Vascular Surgery and Endovascular Therapy, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pa
| | - Carlos H Timaran
- Clinical Heart and Vascular Center, University of Texas Southwestern, Dallas, Tex
| | - Adam W Beck
- Division of Vascular Surgery and Endovascular Therapy, University of Alabama at Birmingham, Birmingham, Ala
| | - Matthew Eagleton
- Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, Mass
| | - Matthew P Sweet
- Division of Vascular Surgery, Department of Surgery, University of Washington Medical Center, Seattle, Wash.
| | | |
Collapse
|
19
|
Katsargyris A, de Marino PM, Botos B, Nagel S, Ibraheem A, Verhoeven ELG. Single Center Experience with Endovascular Repair of Acute Thoracoabdominal Aortic Aneurysms. Cardiovasc Intervent Radiol 2021; 44:885-891. [PMID: 33686461 PMCID: PMC7939448 DOI: 10.1007/s00270-021-02798-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 02/03/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE To investigate feasibility and outcomes of endovascular repair for acute thoracoabdominal aortic aneurysms (TAAA). MATERIALS AND METHODS Data from a single center were retrospectively analyzed. Patients who underwent endovascular repair for acute TAAA between January 2010 and April 2020 were included. Perioperative and mid-term follow-up outcomes were analyzed. Survival, freedom from reintervention, and target vessel patency were calculated by Kaplan-Meier analysis. RESULTS A total of 30 patients (18 men, 67.5 ± 6.9 years) underwent endovascular repair for acute symptomatic (n = 15) or contained ruptured (n = 15) TAAA. An off-the-shelf four-branched stent-graft (T-Branch) was used in 19 (63.3%) patients, a custom-made device (CMD) with expedite order in 5 (16.7%) patients, a CMD with short anticipated delivery time in 3 (10.0%) patients, and a CMD available in the hospital in 3 (10.0%) patients. Technical success was 90.0% (n = 27). Thirty-day mortality was 10% (n = 3). There was no complete persistent paraplegia, but one (3.3%) patient suffered permanent limb weakness. Estimated survival at 1 and 2 years was 86.3% ± 6.4%, and 82.3% ± 7.2%, respectively. Estimated freedom from reintervention at 1 and 2 years was 81.4% ± 7.6% and 73% ± 8.8%. Estimated target vessel patency at 1 and 2 years was 96.6% ± 2% and 92.6% ± 2.9%. CONCLUSION Endovascular treatment of acute TAAA in this selected group of patients was associated with low early mortality and excellent mid-term survival. The off-the-shelf stent-graft option (T-Branch) was used in the majority of patients. Endovascular repair should be considered the first option for suitable acute TAAA.
Collapse
Affiliation(s)
- Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany.
| | - Pablo Marques de Marino
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany
| | - Balazs Botos
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany
| | - Sebastian Nagel
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany
| | - Anas Ibraheem
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany
| | - Eric L G Verhoeven
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University, 90471, Nuremberg, Germany
| |
Collapse
|
20
|
Bosiers M, Kölbel T, Resch T, Tsilimparis N, Torsello G, Austermann M. Early and mid-term results from a postmarket observational study of Zenith t-Branch thoracoabdominal endovascular graft. J Vasc Surg 2021; 74:1081-1089.e3. [PMID: 33684474 DOI: 10.1016/j.jvs.2021.01.070] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 01/29/2021] [Indexed: 10/22/2022]
Abstract
OBJECTIVE We have reported the short-term outcomes regarding the safety of the off-the-shelf Zenith t-Branch multibranched thoracoabdominal stent-graft (William Cook Europe ApS, Bjaeverskov, Denmark) in a postmarket, multicenter study. METHODS Patients who had been treated with the t-Branch device from September 2012 to November 2017 at three European centers were either prospectively or retrospectively enrolled in the present study. Device implantation and postprocedural follow-up were performed according to the standard of care at each center. The primary objectives of the present study were to assess the procedure-related mortality and morbidity at 30 days and 1 year and to assess the presence of endoleaks, device integrity, and stent-graft and branch vessel patency. RESULTS A total of 80 patients were included in the present study (mean age, 71.0 ± 7.4 years; 70.0% male). Most (n = 77) had been treated for thoracoabdominal aortic aneurysms (TAAAs) and the rest for dissection (n = 3). Most TAAAs were stable (72.7%; 56 of 77). The remaining TAAAs were symptomatic (7.8%; 6 of 77) or had a contained rupture (19.5%; 15 of 77). The t-Branch device was successfully deployed in 79 patients. In one patient, the delivery system of the device could not be advanced through the iliac artery. Within 30 days, one patient had died (1.3%). At 1 year, seven patients had died (8.8%), and no aortic rupture or conversion to open surgery had been reported. The 30-day neurologic events included stroke in three patients (3.8%), paraplegia in one (1.3%), and paraparesis in six patients (7.5%). Secondary interventions were required in nine patients (11.3%) during follow-up. Postoperative endoleaks were observed in 37 of 72 patients (51.4%), including type II endoleak in 30, type Ia in 4, and type III endoleak in 6 patients. At 1 year, endoleaks had been reported in 20 patients (16 with type II and 4 with type III). The t-Branch main body graft patency was 100% throughout the 1-year follow-up period. At 30 days after the procedure, all celiac and superior mesenteric artery branches were patent and one left renal and one right renal branch were occluded. At 1 year, occlusion had developed in three bridging stent-grafts for the celiac artery, one for the left renal artery, and two for the right renal artery. CONCLUSION The t-Branch device appears safe, with good 30-day and 1-year mortality and morbidity in the present study, including both stable and symptomatic cases.
Collapse
Affiliation(s)
- Michel Bosiers
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany.
| | - Tilo Kölbel
- University Heart and Vascular Center, Hamburg, Germany
| | | | - Nikolaos Tsilimparis
- University Heart and Vascular Center, Hamburg, Germany; Department of Vascular Surgery, Hospital of the Ludwig Maximilian University, Munich, Germany
| | - Giovanni Torsello
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Martin Austermann
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany
| |
Collapse
|
21
|
Puta B, Fazzini S, Torsello G, Pipitone MD, Austermann M, Beropoulis E, Torsello GF. Preliminary Clinical and Radiologic Outcome of Matched Patients with Thoracoabdominal Aortic Aneurysms Treated by Low-Profile vs Standard Profile Branched Aortic Endografts. Ann Vasc Surg 2021; 75:397-405. [PMID: 33556526 DOI: 10.1016/j.avsg.2021.01.095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 01/15/2021] [Accepted: 01/18/2021] [Indexed: 12/20/2022]
Abstract
BACKGROUND Durability of low-profile branched aortic stent-grafts (LPSG) in the treatment of patients with thoracoabdominal aortic aneurysms (TAAA) remains unclear. Objective of this study is to compare the outcomes of LPSG with standard profile branched aortic stent-grafts (SPSG). METHODS Between January 2016 and January 2020, 225 consecutive patients with TAAA were treated by branched endovascular aortic repair (BEVAR). Twenty-four patients who were treated with a LPSG were compared to 24 patients who received SPSG as a control group. Control patients were selected according to aneurysm size (maximum aneurysm diameter) and extension (Crawford classification) as well as availability of adequate preoperative and postoperative CT-angiograms at 24 months. The primary endpoint was ongoing clinical success defined as successful implantation and freedom from aneurysm- or procedure-related death, secondary intervention, type I or III endoleak, infection, thrombosis, aneurysm expansion or rupture and conversion. Secondary endpoints were radiological changes of the branched endograft (migration, shortening, scoliosis, lordosis, and fracture). RESULTS After a median follow-up of 22.6 (LPSG) and 26.2 months (SPSG), no significant difference was found in terms of technical success (100% in both groups), late mortality (4.2% vs 0%), aneurysm diameter increase (4.2% in both groups) and reinterventions (25% vs 37.5%). Infection, thrombosis, aneurysm expansion or rupture and conversion were not observed. Radiological analysis of aortic graft remodeling showed no fracture and no significant migration, shortening, scoliosis and lordosis of the LPSG (6.1 mm, 7.5 mm, 12.8° and 6.1°) compared to SPSG (3.9 mm, 5.1 mm, 7.9° and 5.6°) after 2 years. CONCLUSION The clinical and radiological findings of the present study showed no increased mortality and complications for the matched patients who underwent treatment with low-profile vs standard-profile BEVAR. This study provides preliminary evidence of safety and efficacy of low-profile branched endografts in patients with demanding iliac access vessels.
Collapse
Affiliation(s)
- Besjona Puta
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Stefano Fazzini
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany.
| | - Giovanni Torsello
- Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany
| | | | - Martin Austermann
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany
| | | | - Giovanni Federico Torsello
- Department of Radiology, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Münster, Germany
| |
Collapse
|
22
|
Branzan D, Geisler A, Grunert R, Steiner S, Bausback Y, Gockel I, Scheinert D, Schmidt A. The Influence of 3D Printed Aortic Models on the Evolution of Physician Modified Stent Grafts for the Urgent Treatment of Thoraco-abdominal and Pararenal Aortic Pathologies. Eur J Vasc Endovasc Surg 2020; 61:407-412. [PMID: 33272811 DOI: 10.1016/j.ejvs.2020.10.023] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 09/21/2020] [Accepted: 10/27/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The aim was to describe the outcomes of high risk patients with symptomatic or contained rupture of pararenal (PRAs) and thoraco-abdominal aortic aneurysms (TAAAs) with anatomy unsuitable for commercially available stent grafts who underwent fenestrated endovascular aneurysm repair (FEVAR) using physician modified stent grafts (PMSGs) planned with 3D image analysis software (3DIMAS), and 3D printed aortic models (3DAMs). METHODS Nineteen consecutive patients (17 male; mean age, 70 ± 9 years) underwent PMSG-FEVAR between 2015 and 2019. 3DAMs to plan the PMSGs were introduced in 2018. End points were all cause mortality, freedom from any endoleak, target vessel patency, and re-intervention. RESULTS Seven patients (36.8%) were treated with PMSGs using 3DIMAS (three PRAs, three type IV, and one type III TAAAs), and 12 patients (63.2%) received PMSGs using 3DAMs (five PRAs, seven type IV TAAAs). Six patients presented with contained aortic rupture and 13 patients were treated for symptomatic aortic aneurysm. Mean aortic diameter was 72 ± 10 mm. The choice of stent graft for fenestration was the Valiant Captivia Closed Web (Medtronic), except for one patient. Sixteen (84.2%) stent grafts were manufactured with four fenestrations. Technical success was 100%. Seventy-one renovisceral branch vessels were targeted with fenestrations. Mean length of hospital stay was 17.3 ± 10.4 days. Thirty day mortality was 0%. Two patients developed reversible spinal cord injury. Mean follow up was 14.4 months (range 1-52 months). During follow up one non-aneurysm related death occurred, and two successful re-interventions were performed: one to re-establish renal artery patency, and one to treat a type 1c endoleak. CONCLUSION PMSGs for urgent treatment of pararenal and thoraco-abdominal aortic aneurysms in high risk patients unsuitable for commercially available stent grafts are feasible and safe. 3D printing technology may improve urgent construction of patient specific devices for treatment of complex aortic pathologies and improve outcomes.
Collapse
Affiliation(s)
- Daniela Branzan
- Department of Vascular Surgery, University Hospital Leipzig, Leipzig, Germany.
| | - Antonia Geisler
- Department of Vascular Surgery, University Hospital Leipzig, Leipzig, Germany
| | - Ronny Grunert
- Department of Neurosurgery, University Hospital Leipzig, Leipzig, Germany
| | - Sabine Steiner
- Department of Interventional Angiology, University Hospital Leipzig, Leipzig, Germany
| | - Yvonne Bausback
- Department of Interventional Angiology, University Hospital Leipzig, Leipzig, Germany
| | - Ines Gockel
- Department of Visceral Surgery, University of Leipzig, Leipzig, Germany
| | - Dierk Scheinert
- Department of Interventional Angiology, University Hospital Leipzig, Leipzig, Germany
| | - Andrej Schmidt
- Department of Interventional Angiology, University Hospital Leipzig, Leipzig, Germany
| |
Collapse
|
23
|
Yang G, Zhang Y, Qiao T, Zhou M, Li X. Experience with physician-modified Ankura™ endografts for endovascular repair of thoracoabdominal aortic aneurysms. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 62:234-241. [PMID: 33185075 DOI: 10.23736/s0021-9509.20.11544-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The aim of this study was to evaluate the early results of fenestrated/branched endovascular aortic repair (F/B-EVAR) of thoracoabdominal aortic aneurysms (TAAAs) using physician-modified Ankura™ endografts (PMEGs). METHODS Sixteen consecutive patients who underwent F/B-EVAR using PMEGs between July 2017 and December 2018 were retrospectively reviewed. The perioperative mortality and morbidity of the PMEG technique were assessed, and the early results of follow-up were evaluated. RESULTS The median age of the patients was 75.3 years old (range: 48-83 years), and 12 (75.0%) patients were male. The median TAAA diameter was 7.1±1.5 cm (range: 5.1-11 cm). The initial technical success rate of vessel revascularization was 98.2% (55 of 56). Target vessel patency was 98.1% (52/53), and freedom from reintervention was 98.1% (52/53) at follow-up. The 30-day mortality rates 6.3%. There was no death during follow-up. CONCLUSIONS PMEGs represent an important innovation, with favorable initial results, in the treatment of patients with complex TAAAs who may be unfit for open repair. In addition, they remain a promising option for high-risk patients in need of urgent repair who cannot wait for a custom-made device.
Collapse
|
24
|
Bilman V, Cambiaghi T, Grandi A, Carta N, Melissano G, Chiesa R, Bertoglio L. Anatomical feasibility of a new off-the-shelf inner branch stent graft (E-nside) for endovascular treatment of thoraco-abdominal aneurysms. Eur J Cardiothorac Surg 2020; 58:1296-1303. [DOI: 10.1093/ejcts/ezaa276] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Revised: 06/23/2020] [Accepted: 06/28/2020] [Indexed: 11/15/2022] Open
Abstract
Abstract
OBJECTIVES
The aim of this study was to evaluate the proportion of thoraco-abdominal aortic aneurysms (TAAAs) that could theoretically be treated with the JOTEC® E-nside® Thoracoabdominal Branch Endoprosthesis off-the-shelf multibranched endograft.
METHODS
Preoperative computed tomography scans of patients with atherosclerotic TAAA treated between 2007 and 2019 were reviewed, and the anatomical feasibility of the E-nside graft was verified by a retrospective study (clinicaltrials.gov: NCT03959670) based on the investigational manufacturer instructions for use. The anatomical factors determining overall feasibility were divided into vascular access (AC) feasibility, aortic (AO) feasibility and visceral vessels (VV) feasibility.
RESULTS
Two hundred sixty-eight patients with thoraco-abdominal aneurysms were analysed: the overall treatment feasibility was 43%. AC feasibility was 78%, AO feasibility 60% and VV feasibility 79%. An iliac diameter <8.5 mm excluded 21% of the patients. Aortic feasibility was limited by infrarenal aortic diameter (16%) and size of aortic lumen at the level of visceral vessels (14%). Visceral vessels feasibility was mainly limited by inadequate number (8%) or diameter (12%) of target vessels. Height and orientation of target vessels were adequate in 97% of the cases. Overall feasibility was negatively influenced by female gender (Odds ratio: 3.89; 95% confidence interval 2.03–7.44; P < 0.001): the limiting factors in this subgroup being iliac diameter, infrarenal aortic diameter and visceral vessels diameter.
CONCLUSIONS
The E-nside off-the-shelf stent graft can be theoretically employed in almost half of the cases from an all-comers cohort of patients with TAAA. Improvement of device profile and creation of a dedicated infrarenal component are warranted to increase overall feasibility. Female gender significantly affects the overall feasibility.
Clinicaltrials.gov
NCT03959670.
Collapse
Affiliation(s)
- Victor Bilman
- Cirurgia Vascular e Endovascular, Pontifícia Universidade Católica do Rio de Janeiro – PUC-Rio, Rio de Janeiro, RJ, Brazil
| | - Tommaso Cambiaghi
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Alessandro Grandi
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Niccolò Carta
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Germano Melissano
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Roberto Chiesa
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Luca Bertoglio
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| |
Collapse
|
25
|
Grandi A, Carta N, Cambiaghi T, Bilman V, Melissano G, Chiesa R, Bertoglio L. Sex-Related Anatomical Feasibility Differences in Endovascular Repair of Thoracoabdominal Aortic Aneurysms With a Multibranched Stent-Graft. J Endovasc Ther 2020; 28:283-294. [DOI: 10.1177/1526602820964916] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Purpose: To evaluate the potential anatomical feasibility of using the off-the-shelf multibranched Zenith t-Branch for the treatment of thoracoabdominal aortic aneurysms (TAAAs) in female patients. Materials and Methods: A total of 268 patients (median age 68 years; 69 women) with degenerative TAAA treated at a single institution by means of open or endovascular repair between 2007 and 2019 were retrospectively analyzed to determine the feasibility of using the Zenith t-Branch based on the manufacturer’s instructions for use. The factors determining overall anatomical feasibility were divided into vascular access, aortic anatomy, and visceral vessels. The results were stratified by sex and compared. A logistic regression model was constructed to determine any association between feasibility and clinical factors or potential confounding variables; results are expressed as the odds ratio (OR) with 95% confidence interval (CI). Results: The overall anatomical feasibility was 39% (22% women vs 45% men, p=0.001). The feasibility was negatively influenced by female sex (p<0.001) in multivariable analysis (OR 2.9, 95% CI 1.5 to 5.4, p=0.001). Vascular access feasibility was 82% (61% women vs 89% men, p<0.001). Aorta feasibility was 65% (52% women vs 69% men, p<0.001), and visceral vessel feasibility was 74% (78% women vs 73% men, p=0.260). An access diameter ≤8.5 mm excluded 17% of the patients (39% women vs 9% men, p<0.001). The aortic feasibility was limited by the infrarenal aortic diameter in 16% of patients (45% women vs 6% men, p<0.001) and the aortic lumen at the visceral vessels in 17% patients (19% women vs 17% men, p=0.741). The visceral vessel feasibility was mainly limited by inadequate numbers or diameters of target vessels. Location and orientation of the target vessels were adequate in 96% of patients. Conclusion: A little more than a third of an all-comers cohort of patients with degenerative TAAA could have been treated with on-label use of the Zenith t-Branch. However, only 22% of women could have been treated because of sex-related anatomical limitations. New generations of multibranched devices should address these differences.
Collapse
Affiliation(s)
- Alessandro Grandi
- Division of Vascular Surgery, “Vita-Salute” San Raffaele University, Milan, Italy
| | - Niccolò Carta
- Division of Vascular Surgery, “Vita-Salute” San Raffaele University, Milan, Italy
| | - Tommaso Cambiaghi
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston, TX, USA
| | - Victor Bilman
- Cirurgia Vascular e Endovascular, Pontifícia Universidade Católica do Rio de Janeiro, Brazil
| | - Germano Melissano
- Division of Vascular Surgery, “Vita-Salute” San Raffaele University, Milan, Italy
| | - Roberto Chiesa
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Luca Bertoglio
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Milan, Italy
| |
Collapse
|
26
|
Outcomes of a novel upper extremity preloaded delivery system for fenestrated-branched endovascular repair of thoracoabdominal aneurysms. J Vasc Surg 2020; 72:470-479. [DOI: 10.1016/j.jvs.2019.09.058] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 09/24/2019] [Indexed: 11/21/2022]
|
27
|
Gallitto E, Faggioli G, Spath P, Pini R, Mascoli C, Ancetti S, Stella A, Abualhin M, Gargiulo M. The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated/branched endograft. J Vasc Surg 2020; 72:16-24. [DOI: 10.1016/j.jvs.2019.08.273] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Accepted: 08/31/2019] [Indexed: 10/25/2022]
|
28
|
Reporting standards for endovascular aortic repair of aneurysms involving the renal-mesenteric arteries. J Vasc Surg 2020; 73:4S-52S. [PMID: 32615285 DOI: 10.1016/j.jvs.2020.06.011] [Citation(s) in RCA: 245] [Impact Index Per Article: 61.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Accepted: 06/05/2020] [Indexed: 12/14/2022]
Abstract
Endovascular aortic aneurysm repair of complex aortic aneurysms requires incorporation of side branches using specially designed aortic stent grafts with fenestrations, directional branches, or parallel stent grafts. These techniques have been increasingly used and reported in the literature. The purpose of this document is to clarify and to update terminology, classification systems, measurement techniques, and end point definitions that are recommended for reports dealing with endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms involving the renal and mesenteric arteries.
Collapse
|
29
|
Edman NI, Bartek MA, Kang PC, Sweet MP. Anatomic Eligibility for Commercial Branched Endograft Repair of Thoracoabdominal Aortic Aneurysms. Ann Vasc Surg 2020; 70:481-490. [PMID: 32603844 DOI: 10.1016/j.avsg.2020.06.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/15/2020] [Accepted: 06/15/2020] [Indexed: 01/15/2023]
Abstract
BACKGROUND First-generation "off-the-shelf" branched endovascular stent grafts are in development for treatment of thoracoabdominal aortic aneurysms (TAAAs). Prior studies have assessed eligibility rates among highly selected cohorts of patients referred for endovascular treatment, and the broader applicability of these devices to all patients with TAAA is unknown. The aims of this study were to assess the overall suitability of the 3 commercial 4-branched devices with or without adjunct procedure(s) in an unselected cohort of patients with TAAA and to identify areas for improvement in the next generation of devices. METHODS A retrospective review of three-dimensional centerline reconstructions of contrast-enhanced computed tomography (CT) imaging was performed in consecutive patients with TAAA seen between 2013 and 2017. All patients with contrast-enhanced CT imaging were included, regardless of prior evaluation for suitability for endovascular repair. Eligibility for a device was assessed based on instructions for use (IFU) from the device manufacturer along with prespecified anatomic criteria. Adjunct procedures were defined as carotid-subclavian revascularization, target vessel endovascular intervention, and iliac conduit/revascularization. RESULTS Of 165 patients with TAAA, 122 had CT scans adequate for study inclusion. Eighteen patients (14.8%) were eligible for at least 1 device by IFU, and 41 (33.6%) could have been made eligible for at least 1 device by an adjunct procedure. Sixty-three (51.6%) were not eligible for any device within IFU even with adjunct procedures, including 31 of 32 patients with TAAA due to dissection. The most common reasons for ineligibility were perivisceral flow channel diameter <20 mm (n = 43) and an inadequate proximal seal zone (n = 29). Women were significantly less likely to be eligible for an off-the-shelf device (P = 0.03) and were more likely to require an iliac procedure to become eligible (P = 0.006). Almost none of the patients with dissection could receive a device even if adjunct procedures were used. CONCLUSIONS Over half of patients with TAAA could not be made eligible for an off-the-shelf device based on manufacturers' criteria, even with adjunct procedures. Women and patients with TAAA due to dissection had higher rates of ineligibility. These data demonstrate that custom fenestrated devices and low-profile devices are needed to expand eligibility for endovascular repair of TAAA.
Collapse
Affiliation(s)
- Natasha I Edman
- Division of Vascular Surgery, Department of Surgery, University of Washington, Seattle, WA
| | - Matthew A Bartek
- Division of Vascular Surgery, Department of Surgery, University of Washington, Seattle, WA
| | - P Chulhi Kang
- Division of Vascular Surgery, Department of Surgery, University of Washington, Seattle, WA
| | - Matthew P Sweet
- Division of Vascular Surgery, Department of Surgery, University of Washington, Seattle, WA.
| |
Collapse
|
30
|
Yang G, Zhang M, Muzepper M, Du X, Wang W, Liu C, Qiao T, Zhou M, Li X. Comparison of Physician-Modified Fenestrated/Branched Stent-Grafts and Hybrid Visceral Debranching Plus Stent-Graft Placement for Complex Thoracoabdominal Aortic Aneurysm Repair. J Endovasc Ther 2020; 27:749-756. [PMID: 32580618 DOI: 10.1177/1526602820934466] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose: To evaluate the immediate postoperative and midterm outcomes of complex thoracoabdominal aortic aneurysm (TAAA) treatment with fenestrated/branched physician-modified endovascular grafts (PMEGs) or open debranching of the visceral aorta with bypass graft revascularization plus endovascular aneurysm exclusion (hybrid repair). Materials and Methods: A retrospective analysis was conducted of 88 patients (mean age 70.0±10.6 years; 73 men) with complex TAAAs who underwent treatment with PMEGs (60, 68%) or a hybrid technique (28, 32%) between 2016 and 2019. The mean aneurysm diameter was 64.5±11.7 mm, and 37 patients (42%) were symptomatic. The Zenith TX2 and Ankura were the main stent-grafts used in the PMEG group. The hybrid technique involved visceral debranching with extra-anatomical bypass graft revascularization and subsequent stent-graft deployment (1- or 2-stage procedure). Results: In the PMEG group, 35 patients received modified stent-grafts with 4 fenestrations, 8 patients had 4 branches per device, and 17 patients had combinations (50 fenestrations and 18 branches) that successfully revascularized 228 of the 240 targets (95%). In the 28 hybrid cases, all 110 target vessels were successfully revascularized with bypass grafts. The overall 30-day mortality was 3.4% (2 PMEG and 1 hybrid), and the early rate of target vessel stenosis/occlusion was 3.3% (5 in PMEG group and 6 in the hybrid repair group). The 30-day morbidity was mainly attributed to pulmonary complications (15%), lower limb ischemia (8%), or spinal cord ischemia with paraplegia (6%). Eleven patients (13%) had deteriorated renal function with a >30% decrease in the glomerular filtration rate. The mean follow-up was 22.3±4.9 months, and mortality was 4.5% (3.3% in the PMEG group vs 7.1% in the hybrid repair group). Conclusion: PMEGs and hybrid techniques seem to be feasible treatment options for aortic aneurysms necessitating visceral vessel revascularization. PMEGs may have a lower morbidity than the hybrid technique, which nonetheless remains an important option available for complex aortic aneurysms.
Collapse
Affiliation(s)
- Guangmin Yang
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Ming Zhang
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Mehmutjan Muzepper
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Xiaolong Du
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Wei Wang
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Cheng Liu
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Tong Qiao
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Min Zhou
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - Xiaoqiang Li
- Department of Vascular Surgery, Drum Tower Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| |
Collapse
|
31
|
Tenorio ER, Squizzato F, Balachandran P, Oderich GS. Endovascular TAAA repair: current status and future challenges. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 2020. [DOI: 10.23736/s1824-4777.20.01436-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
32
|
Cambiaghi T, Grandi A, Bilman V, Melissano G, Chiesa R, Bertoglio L. Anatomic feasibility of the investigational GORE EXCLUDER Thoracoabdominal Branch Endoprosthesis (TAMBE), off-the-shelf multibranched endograft for the treatment of pararenal and thoracoabdominal aortic aneurysms. J Vasc Surg 2020; 73:22-30. [PMID: 32360681 DOI: 10.1016/j.jvs.2020.03.056] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Accepted: 03/18/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the proportion of pararenal aortic aneurysms and thoracoabdominal aortic aneurysms (TAAAs) that could theoretically be treated with the investigational GORE EXCLUDER Thoracoabdominal Branch Endoprosthesis (TAMBE; W. L. Gore & Associates, Flagstaff, Ariz) off-the-shelf multibranched endograft. METHODS The preoperative computed tomography scans of patients with pararenal aortic aneurysms and TAAAs treated at a single institution between 2007 and 2017 were reviewed. This cohort included both open and endovascular repairs performed in either elective or urgent/emergent settings. These studies were included in a retrospective feasibility study to verify anatomic feasibility of the TAMBE graft (with four antegrade portals) employed within the manufacturer's investigational instructions for use during the U.S. pivotal trial. The patient cohort was divided into two groups: extended thoracoabdominal aneurysm (E-TAA)-extent I, II, and III TAAA; and limited pararenal and thoracoabdominal aneurysm (L-TAA)-pararenal aortic aneurysm and extent IV TAAA. The anatomic factors determining the overall theoretical feasibility were further divided into three groups: vascular access feasibility, aortic feasibility, and visceral vessel feasibility. RESULTS Computed tomography scans of 227 patients with degenerative aneurysms were analyzed, 166 with E-TAA and 61 with L-TAA. In the L-TAA group, 49% of the cases could have been treated with the TAMBE endograft alone; access feasibility was 85%, aortic feasibility 74%, and visceral vessel feasibility 72%. In the E-TAA group, only 23% of the cases could have been treated with a TAMBE combined with a GORE CTAG proximal thoracic stent graft; access feasibility was 79%, aortic feasibility 48%, and visceral vessel feasibility 63%. The different feasibility rate was related to a difference in aortic feasibility between L-TAA and E-TAA (74% vs 48%; P = .0008) because of the lack of a dedicated tapered thoracic component. CONCLUSIONS The TAMBE multibranched endograft can theoretically be employed in half of an all-comers cohort of patients with degenerative L-TAA. Development of a dedicated tapered thoracic component is warranted to increase the feasibility for E-TAA, and comparative studies are required to investigate differences with other available off-the-shelf stent grafts.
Collapse
Affiliation(s)
- Tommaso Cambiaghi
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, Tex
| | - Alessandro Grandi
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Victor Bilman
- Cirurgia Vascular e Endovascular, Pontifícia Universidade Católica do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Germano Melissano
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Roberto Chiesa
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Luca Bertoglio
- Division of Vascular Surgery, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy.
| |
Collapse
|
33
|
Simonte G, Fino G, Isernia G, Parlani G, Cieri E, Baccani L, Lenti M. Forced Complete Femoral Approach for Urgent Thoracoabdominal Aneurysm Repair Using an Inner Branched Endograft. Ann Vasc Surg 2020; 64:412.e7-412.e13. [DOI: 10.1016/j.avsg.2019.10.060] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 10/09/2019] [Accepted: 10/09/2019] [Indexed: 11/16/2022]
|
34
|
Sveinsson M, Kristmundsson T, Dias N, Sonesson B, Mani K, Wanhainen A, Resch T. Juxtarenal endovascular therapy with fenestrated and branched stent grafts after previous infrarenal repair. J Vasc Surg 2019; 70:1747-1753. [DOI: 10.1016/j.jvs.2019.01.078] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2018] [Accepted: 01/17/2019] [Indexed: 10/26/2022]
|
35
|
Current status of endovascular treatment for thoracoabdominal aortic aneurysms. Surg Today 2019; 50:1343-1352. [PMID: 31776776 DOI: 10.1007/s00595-019-01917-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Accepted: 10/10/2019] [Indexed: 10/25/2022]
Abstract
Open surgical repair (OSR) for thoracoabdominal aortic aneurysms (TAAAs) is maximally invasive and associated with high rates of operative mortality and perioperative complications including spinal cord ischemia (SCI), despite improvements in surgical techniques and perioperative care. Elderly patients, patients with a history of aortic surgery, and patients with severe comorbidities are often considered ineligible for this surgery and endovascular treatment may be their only treatment option. Total endovascular aneurysm repair (t-EVAR) without debranching surgery does not require thoracotomy and laparotomy and could improve the outcomes of these patients. t-EVAR includes fenestrated EVAR (f-EVAR), multi-branched EVAR (b-EVAR), and physician-modified fenestration endograft (PMFG). Although these techniques have achieved lower mortality rates than OSR, there are concerns about perioperative complications including limb ischemia, SCI, and long-term outcomes such as endograft migration and endoleaks (ELs). This article provides an overview of available endovascular devices for TAAAs and reviews the short and mid-term results of t-EVAR, as well as alternative options.
Collapse
|
36
|
Late failure of a Nellix endoprosthesis treated with the t-Branch off-the-shelf multibranched stent graft. JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES 2019; 5:576-579. [PMID: 31867474 PMCID: PMC6906662 DOI: 10.1016/j.jvscit.2019.10.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Accepted: 10/06/2019] [Indexed: 11/20/2022]
Abstract
A 66-year-old man arrived at our emergency department 3 years after an endovascular aneurysm sealing procedure performed at another center. Computed tomography angiography showed distal migration of a Nellix endoprosthesis (Endologix, Irvine, Calif) and a posterior contained rupture. The left kidney was excluded by an occluded iliac-left renal bypass, which was performed at the time of the Nellix implantation because of unintended coverage. A t-Branch (Cook Medical, Bloomington, Ind) was implanted in an emergency, but the delivery caused disruption of the Nellix limb, requiring relining. Target vessels were bridged with VBX stents (W. L. Gore & Associates, Flagstaff, Ariz). The postoperative course was uneventful except for renal function impairment that was restored 2 weeks later.
Collapse
|
37
|
Technical aspects and 30-day outcomes of the prospective early feasibility study of the GORE EXCLUDER Thoracoabdominal Branched Endoprosthesis (TAMBE) to treat pararenal and extent IV thoracoabdominal aortic aneurysms. J Vasc Surg 2019; 70:358-368.e6. [PMID: 30612825 DOI: 10.1016/j.jvs.2018.10.103] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Accepted: 10/29/2018] [Indexed: 11/24/2022]
Abstract
OBJECTIVE This study reports the technical aspects and 30-day outcomes of the prospective, multicenter early feasibility study designed to evaluate the GORE EXCLUDER Thoracoabdominal Branch Endoprosthesis (TAMBE; W. L. Gore & Associates, Flagstaff, Ariz). METHODS Thirteen patients with pararenal or extent IV thoracoabdominal aortic aneurysms were prospectively enrolled at five U.S sites and one non-U.S. site from 2014 to 2016. The TAMBE included four portals with either retrograde or antegrade renal portal configuration and used GORE VIABAHN Balloon-Expandable Endoprosthesis (W. L. Gore & Associates) for stenting of the renal and mesenteric arteries. The primary end point was procedural safety at 30 days, defined by absence of major adverse events, including any-cause mortality, myocardial infarction, stroke, paraplegia, bowel ischemia, respiratory failure, severe acute kidney injury (>50% decline in estimated glomerular filtration rate), dialysis, and procedural blood loss >1000 mL. RESULTS There were 11 male and two female patients with a mean age of 69 ± 8 years. Mean aneurysm diameter was 61 ± 13 mm. A total of 52 renal and mesenteric arteries were incorporated (4 vessels/patient). Technical success was achieved in 12 patients (92%). One patient had inadvertent occlusion of a right renal artery due to dissection. There was no mortality, aneurysm rupture, conversion to open repair, dialysis, or spinal cord injury. Mean length of hospital stay was 5 ± 3 days. At 30 days, four patients (31%) had major adverse events, all due to procedural blood loss >1000 mL. One patient had a type I endoleak at the distal renal branch, which was successfully treated by placement of an additional renal stent before dismissal. Computed tomography angiography at 30 days showed patent target vessels and no type I or type III endoleak. CONCLUSIONS This study confirms the early feasibility of the TAMBE for treatment of pararenal and extent IV thoracoabdominal aortic aneurysms. The high technical success, no mortality, and low morbidity rate support continuation of clinical investigation in a larger population of patients.
Collapse
|
38
|
Watkins AC, Avramenko A, Soler R, Fabre D, Haulon S. A novel all-retrograde approach for t-Branch implantation in ruptured thoracoabdominal aneurysm. JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES 2018; 4:301-304. [PMID: 30547151 PMCID: PMC6282457 DOI: 10.1016/j.jvscit.2018.09.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 09/11/2018] [Indexed: 10/27/2022]
Abstract
The off-the-shelf t-Branch device (Cook Medical, Bloomington, Ind) significantly advanced the endovascular treatment of ruptured thoracoabdominal aortic aneurysms. Improved techniques for expeditious implantation of the t-Branch may improve clinical outcomes for this emergent procedure. Currently, implantation is described using axillary and femoral access. We describe the repair of a ruptured thoracoabdominal aortic aneurysm exclusively through femoral access aided by a steerable sheath and newer generation, low-profile bridging stents.
Collapse
Affiliation(s)
- A Claire Watkins
- Aortic Center, Hôpital Marie Lannelongue, Université Paris Sud, Le Plessis-Robinson, France.,Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Alla Avramenko
- Aortic Center, Hôpital Marie Lannelongue, Université Paris Sud, Le Plessis-Robinson, France
| | - Raphael Soler
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif.,Department of Vascular and Endovascular Surgery, Hôpital La Timone, Aix-Marseille Université, Marseille, France
| | - Dominique Fabre
- Aortic Center, Hôpital Marie Lannelongue, Université Paris Sud, Le Plessis-Robinson, France
| | - Stephan Haulon
- Aortic Center, Hôpital Marie Lannelongue, Université Paris Sud, Le Plessis-Robinson, France
| |
Collapse
|
39
|
Patient and operating room staff radiation dose during fenestrated/branched endovascular aneurysm repair using premanufactured devices. J Vasc Surg 2018; 68:1281-1286. [PMID: 30369410 DOI: 10.1016/j.jvs.2018.02.031] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 02/17/2018] [Indexed: 11/21/2022]
Abstract
INTRODUCTION Fenestrated endovascular aneurysm repair (FEVAR) is the highest radiation dose procedure performed by vascular surgeons. We sought to characterize the radiation dose to patients and staff during FEVAR procedures with different premanufactured devices. METHODS A single-center prospective study of FEVARs was performed over 24 months. Three FEVAR devices were included: off-the-shelf (OTS; t-Branch, p-Branch), Zenith Fenestrated (ZFen), and investigational custom-made devices (CMDs). Radiation doses to the surgeon, trainee, anesthesiologist, and scrub/circulating nurses were measured using a personal dosimetry system (DoseAware, Philips Healthcare, Amsterdam, The Netherlands). Procedure type, patient body mass index (BMI), reference air kerma (RAK), and kerma area product (KAP) were recorded. RAK and KAP were corrected for BMI based on an exponential fit of fluoroscopy dose rate and the dose per radiographic frame. Operator dose was corrected for BMI by the ratio of corrected to actual KAP. A one-sided Wilcox rank-sum test was used to compare personnel radiation doses, RAKs, and KAPs between procedure types. Statistical significance was set at P ≤ .05. RESULTS There were 80 FEVARs performed by a single surgeon on a Philips Allura XperFD20 fluoroscopy system equipped with Clarity technology. Average BMI was 27 kg/m2. Sixty CMDs (36 four-, 21 three-, and 3 two-vessel fenestrations), 11 ZFens (8 three- and 3 two-vessel fenestrations), and 9 OTS devices (4 p-Branch, 5 t-Branch) were included. ZFens had significantly lower patient (1800 mGy vs 2950 mGy; P = .004), operator (120 μSv vs 370 μSv; P = .004), assistant (60 μSv vs 210 μSv; P = .003), circulator (10 μSv vs 30 μSv; P = .049), and scrub nurse dose (10 μSv vs 40 μSv; P = .02) compared with CMDs. OTS devices had significantly lower operator (220 μSv vs 370 μSv; P = .04), assistant (110 μSv vs 210 μSv; P = .02), and circulator doses (4 μSv vs 30 μSv; P = .001) compared with CMDs. Four-vessel fenestrated devices had significantly higher patient dose (3020 mGy) compared with three-vessel FEVARs (2670 mGy; P = .03) and two-vessel FEVARs (1600 mGy; P = .0007), and significantly higher operator dose (440 μSv) compared with three-vessel FEVARs (170 μSv; P = .0005). Patient dose was lowest with ZFens. Operating room personnel dose was lower with ZFens and OTS devices compared with CMDs. Four-vessel fenestrations required significantly more radiation compared with those involving three-vessel fenestrations; however, the dose increase was only 12% and should not preclude operators from extending coverage, if anatomically required. CONCLUSIONS Overall, patient and personnel radiation doses during FEVAR with all devices were within acceptable limits and lower in our series than previously reported.
Collapse
|
40
|
Spanos K, Theodorakopoulou M, Debus ES, Rohlffs F, Heidemann F, Kölbel T, Tsilimparis N. Accurate Orientation of the t-Branch Off-the-Shelf Multibranched Endograft After Deployment in Urgent Cases. J Endovasc Ther 2018; 25:442-449. [DOI: 10.1177/1526602818779372] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To evaluate the orientation of the standardized off-the-shelf multibranched t-Branch after implantation in urgent thoracoabdominal aortic aneurysm (TAAA) repairs, to characterize the impact of branch malorientation on procedural success, and to identify any predictive factors associated with malorientation. Methods: A retrospective analysis was conducted of 42 consecutive patients (mean age 73.3±7 years; 25 men) with urgent TAAA presentation treated with the t-Branch from January 2014 to June 2017. The primary objective was to quantify the preoperative clock position of the target vessels and determine any rotational deviation between the pre- and postoperative measurements and between the postoperative measurements and the standard branch configuration. Secondary outcomes were to identify factors influencing malorientation (>2 clock face hours) that could affect outcome. Results were compared for early (learning curve; n=18) vs late (n=24) experience and for adherence to (n=23) vs nonobservance of (n=19) the instructions for use (IFU). Results: Technical success was 93% (39/42). No significant difference in rotational deviation was identified between patients treated within the IFU vs outside the IFU. Seven (17%) patients had at least one target vessel maloriented after the procedure, which was not associated with total procedure time, fluoroscopy time, contrast volume, radiation dose, or adherence to the IFU. Female gender was associated with increased rotational deviation in postprocedure measurement for the celiac trunk (p=0.044) and superior mesenteric artery (SMA; p=0.006). Female gender was also associated with increased rotational deviation between the branch origin after deployment and the standard configuration of the t-Branch for every target vessel [celiac trunk (p=0.005), SMA (p=0.001), right renal artery (p=0.037), and left renal artery (p=0.003)]. Conclusion: The implantation of the t-Branch device in urgent cases achieved accurate apposition without rotational deviation between the target vessels and the position of the endograft branches. Gender may have an impact on orientation of the device. The t-Branch appears to have a “forgiving” nature for higher malorientation with no effect on procedure time, target vessel revascularization, or early branch patency.
Collapse
Affiliation(s)
- Konstantinos Spanos
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Myrto Theodorakopoulou
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - E. Sebastian Debus
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Fiona Rohlffs
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Franziska Heidemann
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Tilo Kölbel
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Nikolaos Tsilimparis
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| |
Collapse
|
41
|
Hongku K, Sonesson B, Björses K, Holst J, Resch T, Dias NV. Mid-term Outcomes of Endovascular Repair of Ruptured Thoraco-abdominal Aortic Aneurysms with Off the Shelf Branched Stent Grafts. Eur J Vasc Endovasc Surg 2018; 55:377-384. [DOI: 10.1016/j.ejvs.2017.11.021] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Accepted: 11/20/2017] [Indexed: 10/18/2022]
|
42
|
Bertoglio L, Cambiaghi T, Ferrer C, Baccellieri D, Verzini F, Melissano G, Chiesa R, Tshomba Y. Comparison of sacrificed healthy aorta during thoracoabdominal aortic aneurysm repair using off-the-shelf endovascular branched devices and open surgery. J Vasc Surg 2018; 67:695-702. [DOI: 10.1016/j.jvs.2017.08.052] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 08/15/2017] [Indexed: 11/26/2022]
|
43
|
Mascoli C, Vezzosi M, Koutsoumpelis A, Iafrancesco M, Ranasinghe A, Clift P, Mascaro J, Claridge M, Adam DJ. Endovascular Repair of Acute Thoraco-abdominal Aortic Aneurysms. Eur J Vasc Endovasc Surg 2018; 55:92-100. [DOI: 10.1016/j.ejvs.2017.11.003] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 11/07/2017] [Indexed: 10/18/2022]
|
44
|
Spanos K, Kölbel T, Theodorakopoulou M, Heidemann F, Rohlffs F, Debus ES, Tsilimparis N. Early Outcomes of the t-Branch Off-the-Shelf Multibranched Stent-Graft in Urgent Thoracoabdominal Aortic Aneurysm Repair. J Endovasc Ther 2017; 25:31-39. [DOI: 10.1177/1526602817747282] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose: To assess the short-term outcomes of the multibranched off-the-shelf t-Branch stent-graft for urgent thoracoabdominal aortic aneurysm (TAAA) repair and to evaluate the impact on outcomes of the learning curve and adherence to the instruction for use (IFU). Methods: Between 2014 and 2017, 42 patients (mean age 73.3±7 years; 26 men) underwent urgent TAAA treatment using the t-Branch stent-graft [18 in the early (2014–2015) period and 24 in the late (2016–2017) period]. Nearly half the patients were symptomatic (n=18) and 12 had contained rupture. Aneurysm diameter >80 mm was present in 12 (mean diameter 77.7±13.2 mm). Nineteen patients did not meet the IFU for the t-Branch due to target vessel anatomy. The primary endpoints were spinal cord ischemia (SCI), renal function impairment, and 30-day mortality. Target vessel patency and endoleak incidence were assessed at 30 days. Multivariate analyses examined associations between perioperative variables and outcomes; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). Results: The technical success rate was 93% (39/42). Successful catheterization was achieved in 150/155 target vessels (97%). The postoperative SCI rate was 21% (5 paraplegia/4 transient paraparesis) and was correlated with age (OR 1.26, 95% CI 1.01 to 1.56, p=0.04). The renal function impairment rate was 23% (10/42; 2 temporary, 2 permanent dialysis) and was correlated with early experience (OR 7.74, 95% CI 1.3 to 43.9, p=0.019). The 30-day mortality was 14% (no intraoperative deaths); no factor was associated with mortality. During the first month, the incidences of type I, II, and III endoleaks were 0%, 43%, and 0%, respectively; branch patency was 99% (150/151). Procedure time decreased in the later experience (479±333 vs 407±25 minutes, p=0.09), though it was increased in cases outside the IFU (497±135 vs 389±118 minutes, p=0.009), along with fluoroscopy time (121±48 vs 92±33 minutes, p=0.036). Conclusion: Endovascular repair of urgent TAAA using the t-Branch is a feasible treatment option with acceptable 30-day mortality and morbidity in terms of SCI and renal function impairment. Adherence to the IFU prolonged procedure time but had no effect on outcomes. Increased experience of such cases over time may improve outcomes.
Collapse
Affiliation(s)
- Konstantinos Spanos
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Tilo Kölbel
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Myrto Theodorakopoulou
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Franziska Heidemann
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Fiona Rohlffs
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Eike Sebastian Debus
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| | - Nikolaos Tsilimparis
- German Aortic Center Hamburg, Department of Vascular Medicine, University Heart Center, Hamburg, Germany
| |
Collapse
|
45
|
Gallitto E, Gargiulo M, Freyrie A, Pini R, Mascoli C, Ancetti S, Faggioli G, Stella A. Off-the-shelf multibranched endograft for urgent endovascular repair of thoracoabdominal aortic aneurysms. J Vasc Surg 2017; 66:696-704.e5. [DOI: 10.1016/j.jvs.2016.12.129] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Accepted: 12/30/2016] [Indexed: 11/30/2022]
|
46
|
Wolosker N, Fioranelli A, Ferreira M, Tachibana A, Lembrança L, Oliveira C. Endovascular Repair of Ruptured Thoracoabdominal Aortic Aneurysm with an Off-the-shelf Endoprosthesis. Ann Vasc Surg 2017; 43:312.e1-312.e4. [DOI: 10.1016/j.avsg.2017.02.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Accepted: 02/19/2017] [Indexed: 10/19/2022]
|
47
|
Gemayel G, Verdon G, Murith N, Huber C. Rescue of a Failing Endovascular Infrarenal Aortic Repair Using an Off-The-Shelf Branched Endograft. Ann Vasc Surg 2017; 45:269.e15-269.e18. [PMID: 28739451 DOI: 10.1016/j.avsg.2017.07.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 07/05/2017] [Accepted: 07/10/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND Proximal aortic dilation following open and endovascular aortic repair (EVAR) is a well-known phenomenon. If severe enough, it may lead to late onset of type Ia endoleak that jeopardizes the proximal seal. METHODS We report the case of a patient previously treated by EVAR for an infrarenal aneurysm who developed a type Ia endoleak after proximal aortic dilation. His aneurysms enlarged to 10 cm mandating a rapid repair without the delay for a custom-made device. RESULTS We successfully used the off-the-shelf thoracic t-Branch graft (Cook, Bloomington, IN) with its 4 branches to treat the dilated aorta and seal the endoleak. CONCLUSION The off-the-shelf t-Branch is a useful option in patient with previous EVAR presenting with proximal aortic dilation and endoleak who cannot wait for a custom-made device.
Collapse
Affiliation(s)
- Gino Gemayel
- Cardiovascular Surgery Department, Geneva University Hospitals, Faculty of Medicine, University of Geneva, Geneva, Switzerland.
| | - Gabriel Verdon
- Cardiovascular Surgery Department, Geneva University Hospitals, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Nicolas Murith
- Cardiovascular Surgery Department, Geneva University Hospitals, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Christoph Huber
- Cardiovascular Surgery Department, Geneva University Hospitals, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
48
|
Lin TC, Shih CC. Review of Treatment for Thoracoabdominal Aortic Aneurysm, and the Modern Experience of Multi-Branched Endograft in Taiwan. ACTA CARDIOLOGICA SINICA 2017; 33:1-9. [PMID: 28115801 DOI: 10.6515/acs20160401a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Thoracoabdominal aortic aneurysm (TAAA) is a complicated aortic disease. Most treatments for other aortic aneurysms have already shifted from conventional open surgery to endovascular operation; but for TAAA, open surgery remains the gold standard treatment. Several alternative treatments such as hybrid operation as well as endovascular techniques are utilized for the treatment of TAAA. Some of the procedures combine off-the-shelf devices such as the chimney procedure. Some other procedures required custom-made specialized stent grafts. A new off-the-shelf multi-branched endograft, T-branch graft, was released in late 2012, though it was not introduced into Taiwan until 2015. Ultimately, also we plan to report the experience of multi-branched endograft in Taiwan.
Collapse
Affiliation(s)
- Ting Chao Lin
- Department of Cardiovascular Surgery, Taipei Veterans General Hospital, Taoyuan Branch, Taoyuan; ; Department of Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Chun Che Shih
- Department of Cardiovascular Surgery, Taipei Veterans General Hospital; ; Department of Medicine, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| |
Collapse
|
49
|
Heidemann F, Diener H, Debus S, Perez D, Kölbel T, Tsilimparis N. Repair of a Contained Ruptured Paravisceral Aortic Aneurysm Using a Surgeon-Modified Fenestrated Endograft and Development of an Aortogastric Fistula. Ann Vasc Surg 2016; 36:294.e13-294.e17. [DOI: 10.1016/j.avsg.2016.03.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2015] [Revised: 03/07/2016] [Accepted: 03/23/2016] [Indexed: 11/27/2022]
|
50
|
Fernandez CC, Sobel JD, Gasper WJ, Vartanian SM, Reilly LM, Chuter TA, Hiramoto JS. Standard off-the-shelf versus custom-made multibranched thoracoabdominal aortic stent grafts. J Vasc Surg 2016; 63:1208-15. [DOI: 10.1016/j.jvs.2015.11.035] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 11/03/2015] [Indexed: 10/22/2022]
|