1
|
Schild-Suhren S, Yilmaz E, Biggemann L, Seif A, Torsello GF, Uhlig A, Ghadimi M, Bösch F. [Management of Injuries to the Parenchymal Abdominal Organs]. Zentralbl Chir 2024. [PMID: 38684170 DOI: 10.1055/a-2301-7951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
The most common organs affected by abdominal trauma are the spleen and the liver, often in combination. Pancreatic injuries are rare. In the case of blunt abdominal trauma, which is much more common, a clinical and laboratory examination as well as sonography should be performed. In the initial assessment, the circulatory situation must be screened. If there is haemodynamic instability and presentation of free fluid, an emergency laparotomy is indicated. If the situation is stable or stabilised and a pathological sonography is present, it is essential to perform triphasic contrast enhanced computed tomography, which is also mandatory in polytraumatised patients. If a renal injury is suspected, a late venous phase should be attached. In addition to the classification of the injury, attention should be paid to possible vascular injury or active bleeding. In this case, angiography with the possibility of intervention should be performed. Endoscopic treatment is possible for injuries of the pancreatic duct. If the imaging does not reveal any intervention target and a circulation is stable, a conservative approach is possible with continuous monitoring using clinical, laboratory and sonographic controls. Most injuries can be successfully treated by non-operative management (NOM).There are various surgical options for treating the injury, such as local and resecting procedures. There is also the option of "damage control surgery" with acute bleeding control and second look. Complex surgical procedures should be performed at centres. Postoperative complications arise out of elective surgery.In the less common case of penetrating abdominal trauma, the actual extent of the injury cannot be estimated from the visible wound. Here again, the circulatory situation determines the next steps. An emergency laparotomy should be carried out in case of instability. If the condition is stable, further diagnostics should be performed using contrast enhanced computed tomography. If penetration through the peritoneum cannot be clearly excluded, diagnostic laparoscopy should be performed.
Collapse
Affiliation(s)
- Stina Schild-Suhren
- Klinik für Allgemein-, Viszeral- und Kinderchirurgie, Universitätsmedizin Göttingen, Gottingen, Deutschland
| | - Elif Yilmaz
- Klinik für Allgemein-, Viszeral- und Kinderchirurgie, Universitätsmedizin Göttingen, Gottingen, Deutschland
| | - Lorenz Biggemann
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsmedizin Göttingen, Gottingen, Deutschland
| | - Ali Seif
- Institut für Diagnostische und Interventionelle Radiologie, Georg-August-Universität Göttingen, Gottingen, Deutschland
| | - Giovanni Federico Torsello
- Institut für Diagnostische und Interventionelle Radiologie, Georg-August-Universität Göttingen, Gottingen, Deutschland
| | - Annemarie Uhlig
- Klinik für Urologie, Universitätsmedizin Göttingen, Göttingen, Deutschland
| | - Michael Ghadimi
- Klinik für Allgemein-, Viszeral- und Kinderchirurgie, Universitätsmedizin Göttingen, Gottingen, Deutschland
| | - Florian Bösch
- Klinik für Allgemein-, Viszeral- und Kinderchirurgie, Universitätsmedizin Göttingen, Gottingen, Deutschland
| |
Collapse
|
2
|
Richter J, Lindner AK, Geisel D, Fleckenstein FN, Torsello GF, Millet Pascual-Leone B, Ivanov O, Zöllner C, Wilde ACB, Equihua Martinez G. Percutaneous drainage and combined praziquantel-albendazole therapy: a novel approach for the treatment of simple echinococcal liver cysts. Z Gastroenterol 2024; 62:500-507. [PMID: 37729942 DOI: 10.1055/a-2084-3735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Cystic echinococcosis (CE) is a worldwide helminthic zoonosis causing serious disease in humans. The WHO Informal Working Group on Echinococcosis recommends a stage-specific treatment approach of hepatic CE that facilitates the decision on what therapy option is most appropriate. Percutaneous aspiration, instillation of a scolicide, e.g., ethanol or hypertonic saline, and subsequent re-aspiration (PAIR) have been advocated for treating medium-size unilocular WHO-stage CE1 cysts. PAIR can pose a risk of toxic cholangitis because of spillage of ethanol in the case of a cysto-biliary fistula or of life-threatening hypernatriaemia when hypertonic saline is used. The purpose of our study is to develop an alternative, safe, minimally invasive method to treat CE1 cysts, avoiding the use of toxic topic scolicides.We opt for percutaneous drainage (PD) in four patients: the intrahepatic drainage catheter is placed under CT-fluoroscopy, intracystic fluid is aspirated, and the viability of intracystic echinococcal protoscolices is assessed microscopically. Oral praziquantel (PZQ) is added to albendazole (ABZ) instead of using topical scolicidals.Protoscolices degenerate within 5 to 10 days after PZQ co-medication at a cumulative dosage of 250 to 335 mg/kg, and the cysts collapse. The cysts degenerate, and no sign of spillage nor relapse is observed in the follow-up time of up to 24 months post-intervention.In conclusion, PD combined with oral PZQ under ABZ coverage is preferable to PAIR in patients with unilocular echinococcal cysts.
Collapse
Affiliation(s)
- Joachim Richter
- Institute of International Health, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Andreas K Lindner
- Institute of International Health, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Dominik Geisel
- Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | - Olga Ivanov
- Institute of International Health, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Caroline Zöllner
- Department of Gastroenterology and Hepatology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | | | | |
Collapse
|
3
|
Torsello GF, Stavroulakis K, Bisdas T, Cardona Y, Wichmann K, Torsello GB. Treatment of Femoropopliteal Artery Disease with Polymer-Coated Drug-Eluting Stent: 5-Year Results of a Prospective, Non-Randomized Study Including the Halo Phenomenon. Cardiovasc Intervent Radiol 2024; 47:177-185. [PMID: 38228879 PMCID: PMC10844144 DOI: 10.1007/s00270-023-03652-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 12/11/2023] [Indexed: 01/18/2024]
Abstract
PURPOSE To investigate the long-term results of the Eluvia drug-eluting stent (DES) implantation for femoropopliteal arterial disease, including the 'halo' phenomenon. Long-term data of DES is scarce. A focal reaction ('halo') following Eluvia DES deployment has been described. However, the long-term clinical impact of this phenomenon remains unclear. METHODS This prospective, non-randomized, single-arm study included 130 consecutive patients treated with an Eluvia DES for symptomatic femoropopliteal disease between March 2016 and December 2018. Clinical outcomes and imaging were assessed after 6 months and annually thereafter for up to 5 years. The primary outcome measure was primary patency. Secondary outcomes were freedom from clinically driven target lesion revascularization (CD-TLR), freedom from major amputation, overall survival and amputation-free survival rates. RESULTS The primary patency was 65% at 5 years. The freedom from CD-TLR and from major amputation at 5 years was 79 and 96%, respectively. The overall survival and amputation-free survival rates were 88 and 83% at 60 months, respectively. Out of the 27 patients with a halo sign, two showed an increased (7.4%) and 6 (22.2%) a decreased diameter. In 19 cases (70.4%), the diameter remained unchanged at the latest follow-up. The presence of the 'halo' sign was associated with increased primary patency (87% versus 59%, HR: 2.48, 95%CI 1.19-5.16, P = .015). CONCLUSIONS The presented patient cohort treated with the Eluvia DES for femoropopliteal artery lesions indicates durable efficacy and a good safety profile regardless of the halo phenomenon. The results need to be confirmed in a larger patient cohort. LEVEL OF EVIDENCE III Non-randomized controlled cohort/follow-up study.
Collapse
Affiliation(s)
- Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology, Institute of Diagnostic and Interventional Radiology, Göttingen Medical Center, University Medical Center Göttingen, Robert-Koch-Strasse 40, 37075, Göttingen, Germany.
| | | | - Theodosios Bisdas
- Department of Vascular Surgery, Athens Medical Center, Athens, Greece
| | - Yamel Cardona
- Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany
| | - Katrin Wichmann
- Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany
| | | |
Collapse
|
4
|
Kostyrko B, Rubarth K, Althoff C, Zibell M, Neizert CA, Poch F, Torsello GF, Gebauer B, Lehmann K, Niehues SM, Mews J, Diekhoff T, Pohlan J. Evaluation of Different Registration Algorithms to Reduce Motion Artifacts in CT-Thermography (CTT). Diagnostics (Basel) 2023; 13:2076. [PMID: 37370971 DOI: 10.3390/diagnostics13122076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/06/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
Computed tomography (CT)-based Thermography (CTT) is currently being investigated as a non-invasive temperature monitoring method during ablation procedures. Since multiple CT scans with defined time intervals were acquired during this procedure, interscan motion artifacts can occur between the images, so registration is required. The aim of this study was to investigate different registration algorithms and their combinations for minimizing inter-scan motion artifacts during thermal ablation. Four CTT datasets were acquired using microwave ablation (MWA) of normal liver tissue performed in an in vivo porcine model. During each ablation, spectral CT volume scans were sequentially acquired. Based on initial reconstructions, rigid or elastic registration, or a combination of these, were carried out and rated by 15 radiologists. Friedman's test was used to compare rating results in reader assessments and revealed significant differences for the ablation probe movement rating only (p = 0.006; range, 5.3-6.6 points). Regarding this parameter, readers assessed rigid registration as inferior to other registrations. Quantitative analysis of ablation probe movement yielded a significantly decreased distance for combined registration as compared with unregistered data. In this study, registration was found to have the greatest influence on ablation probe movement, with connected registration being superior to only one registration process.
Collapse
Affiliation(s)
- Bogdan Kostyrko
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Kerstin Rubarth
- Institute for Biometry and Clinical Epidemiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
- Berlin Institute of Health, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10178 Berlin, Germany
| | - Christian Althoff
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Miriam Zibell
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Christina Ann Neizert
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Franz Poch
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Giovanni Federico Torsello
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Bernhard Gebauer
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Kai Lehmann
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Stefan Markus Niehues
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Jürgen Mews
- Canon Medical Systems Europe BV, Global Research & Development Center, 2718 RP Zoetermeer, The Netherlands
| | - Torsten Diekhoff
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Julian Pohlan
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
- Berlin Institute of Health, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10178 Berlin, Germany
| |
Collapse
|
5
|
Özdemir-van Brunschot DMD, Torsello GB, Litterscheid S, Berchiolli R, Troisi N, Torsello GF. Correction to: Sex Differences in Endovascular Treatment of Isolated Popliteal Lesions. Cardiovasc Intervent Radiol 2022; 45:1575. [DOI: 10.1007/s00270-022-03258-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Torsello GF. [Endovascular aneurysm repair (EVAR) : Update D]. Radiologie (Heidelb) 2022; 62:580-585. [PMID: 35759019 DOI: 10.1007/s00117-022-01020-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/24/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND Abdominal aortic aneurysms can either be treated by open surgery or endovascular repair. In both cases, prostheses are implanted to prevent potentially lethal aortic ruptures. OBJECTIVES Studies seeking to identify the optimal treatment came to diverging conclusions. The goal of this article is to shed light on the discussion of which treatment option is to be preferred. MATERIALS AND METHODS This article summarizes the relevant studies on elective and emergency abdominal aortic aneurysm repair. The presented studies are discussed, and results are interpreted and compared. RESULTS While most studies indicate lower short-term mortality rates in endovascular aneurysm repair (EVAR), mortality rates converged in multiple trials and even showed a lower mortality rate for open repair in mid-term analyses. Most recent studies indicate long-term equivalence in terms of mortality and a higher rate of secondary interventions in EVAR patients. CONCLUSIONS The current body of literature indicates no real advantage of one therapy over another. The choice of therapy should depend on anatomic, clinical, and logistic criteria.
Collapse
|
7
|
Torsello GF. [Update on thoracic endovascular aneurysm repair : New stent graft designs]. Radiologie (Heidelb) 2022; 62:551-555. [PMID: 35759018 DOI: 10.1007/s00117-022-01032-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/31/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND In the last decade, new stent graft designs have evolved to tackle challenges in thoracic endovascular aortic repair. A specific focus on access vessel issues has led to the introduction of new low-profile endograft designs for most of the major products. OBJECTIVE The main objective of this article is to provide an overview of the available publications on new stent graft designs. MATERIALS AND METHODS Assessing recent publications on the major reiterations of thoracic endografts, benefits and drawbacks are discussed. RESULTS Recent reiterations of major endografts for thoracic aortic endovascular repair have focused mainly on the development of low-profile devices. Through alterations on graft fabric as well as stent material and design, delivery systems were reduced in profile, thus, reducing access vessel complications or enabling an endovascular procedure altogether. Long-term data are already available for one endoprosthesis. Other refinements include in situ adaptation of the stent graft to the aortic arch curvature as well as the option of staged deployment to allow more precision and reduce manipulation close to supra-aortic branches. CONCLUSIONS Especially in the case of low-profile endografts, preliminary and long-term results of access vessel complications are promising. In order to draw final conclusions as to how durable the results of aneurysm exclusion are, more long-term studies are warranted.
Collapse
Affiliation(s)
- Giovanni Federico Torsello
- Ärztliche Leitung Angiographie/Interventionsradiologie CCM, Klinik für Radiologie - Arbeitsbereich Interventionelle Radiologie, Campus Charité Mitte, Campus Virchow-Klinikum, CC 06 Diagnostische und Interventionelle Radiologie und Nuklearmedizin, Charité - Universitätsmedizin Berlin, Berlin, Deutschland.
| |
Collapse
|
8
|
Psilopatis I, Fleckenstein FN, Collettini F, Can E, Frisch A, Gebauer B, Fehrenbach U, Torsello GF, Schnapauff D, David M, Wieners G. Short- and long-term evaluation of disease-specific symptoms and quality of life following uterine artery embolization of fibroids. Insights Imaging 2022; 13:106. [PMID: 35727408 PMCID: PMC9213618 DOI: 10.1186/s13244-022-01244-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 05/28/2022] [Indexed: 11/21/2022] Open
Abstract
Background The purpose of this study is to evaluate uterine artery embolization (UAE) for the management of symptomatic uterine leiomyomas regarding changes in quality of life after treatment in a large patient collective. This study retrospectively analyzed prospectively acquired standardized questionnaires of patients treated with UAE. Clinical success was evaluated before and after embolization. Patients were stratified into short- (≤ 7 months) and long-term (> 7 months) follow-up groups depending on the time of completion of the post-interventional questionnaire. Uterine leiomyomas were furthermore divided into small (< 10 cm) and large (≥ 10 cm) tumors based on the diameter of the dominant fibroid.
Results A total of 245 patients were included into the final data analysis. The Kaplan–Meier analysis showed a cumulative clinical success rate of 75.8% after 70 months until the end of follow-up (9.9 years). All questionnaire subscales showed a highly significant clinical improvement from baseline to short- and long-term follow-up (p < 0.001). Patients with small fibroids showed a significantly better response to UAE in multiple subcategories of the questionnaire than patients with fibroids ≥ 10 cm who had a twofold higher probability of re-intervention in the Cox-regression model. Conclusions UAE is an effective treatment method for symptomatic fibroids that leads to quick relief of fibroid-related symptoms with marked improvement of quality of life and is associated with a low risk for re-interventions. Patients with small fibroids tend to show a better response to UAE compared to patients with large fibroids. Trial registration Charité institutional review board, EA4/167/20. Registered 27 November 2020—Retrospectively registered. https://ethikkommission.charite.de/ Supplementary Information The online version contains supplementary material available at 10.1186/s13244-022-01244-1.
Collapse
Affiliation(s)
- Iason Psilopatis
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,Department of Gynecology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Florian Nima Fleckenstein
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany. .,Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Clinician Scientist Program, Berlin, Germany.
| | - Federico Collettini
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.,Berlin Institute of Health at Charité - Universitätsmedizin Berlin, BIH Biomedical Innovation Academy, BIH Charité Clinician Scientist Program, Berlin, Germany
| | - Elif Can
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Anne Frisch
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernhard Gebauer
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Uli Fehrenbach
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | | | - Matthias David
- Department of Gynecology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Gero Wieners
- Department of Diagnostic and Interventional Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
9
|
Segger L, Auer TA, Fleckenstein F, Fehrenbach U, Federico Torsello G, Frisch A, Jonczyk M, Hamm B, Gebauer B. CT fluoroscopy-guided percutaneous gastrostomy (CT-PG) – A single center experience in 233 patients. Eur J Radiol 2022; 152:110333. [DOI: 10.1016/j.ejrad.2022.110333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 04/11/2022] [Accepted: 04/26/2022] [Indexed: 11/16/2022]
|
10
|
Kapahnke S, Bürger M, Torsello GF, Omran S, Hinterseher I, Greiner A, Frese JP. Cannulation of visceral vessels using a steerable sheathin fenestrated and branched aortic endografts. Ann Vasc Surg 2022; 85:305-313. [PMID: 35271960 DOI: 10.1016/j.avsg.2022.02.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/18/2022] [Accepted: 02/19/2022] [Indexed: 11/01/2022]
Abstract
INTRODUCTION A critical step in the endovascular treatment of complex aortic aneurysm is the cannulation and stenting of renovisceral vessels, especially in cases with a complex anatomy or atherosclerotic lesions. This study aimed to demonstrate the results of renovisceral vessel cannulation using a steerable sheath in fenestrated or branched endovascular aortic procedures (FB-EVAR). METHODS Patients undergoing elective FB-EVAR for asymptomatic thoracoabdominal or juxtarenal aneurysm at a single tertiary referral center from 2016 to 2019 were included in this study. Underlying pathologies, renovisceral target vessels (TV), technical success (TS), freedom from reintervention (FFR), and TV patency were assessed. Target vessels were categorized as challenging or non-challenging TV. RESULTS Fifty-three patients (median age 73 (Q1, Q3 (68 - 80)); 43 male (81%)) who underwent elective FB-EVAR were included. Indications comprised thoracoabdominal aneurysms (Crawford I-IV) (n = 26; 49%), juxtarenal aneurysms (n = 23; 43.5%) and penetrating aortic ulcers (PAU) (n = 4; 7.5%). Two patients (4%) had prior open aortic surgery, and three patients (6%) had undergone a failed standard EVAR before. Of the 196 treated TV, 131 (67%) were categorized as challenging. Cannulation was successful in 194 of 196 vessels (99%). A total of three TV (1.5%) showed periprocedural complications. No significant difference was found in the rate of intraoperative complications between challenging versus non-challenging TV (p = 0.457). One patient died within 30 days of the procedure (1.9%). No stroke or intestinal ischemia occurred. After 12, 24, and 36 months, the survival rate was 87%, 87%, and 81%, respectively Primary patency after 12 months was 98.6%, and 97.9% of vessels remained FFR during follow-up. CONCLUSION Transfemoral, retrograde cannulation of renovisceral vessels using a steerable sheath is feasible and safe and provides good mid-term results, especially in cases with challenging renovisceral vessels. The potential complications of antegrade vascular access can be avoided.
Collapse
Affiliation(s)
- Sebastian Kapahnke
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Vascular Surgery, Hindenburgdamm 30, 12203 Berlin, Germany.
| | - Matthias Bürger
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Vascular Surgery, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Giovanni Federico Torsello
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Safwan Omran
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Vascular Surgery, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Irene Hinterseher
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Vascular Surgery, Hindenburgdamm 30, 12203 Berlin, Germany; Medizinische Hochschule Brandenburg Theodor Fontane - Campus Neuruppin, Vascular Surgery; Fehrbelliner Str. 38, 16816 Neuruppin, Germany
| | - Andreas Greiner
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Vascular Surgery, Hindenburgdamm 30, 12203 Berlin, Germany
| | - Jan Paul Frese
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Vascular Surgery, Hindenburgdamm 30, 12203 Berlin, Germany
| |
Collapse
|
11
|
Nunninger M, Torsello GF. [67/m-Incidental finding of a solitary pulmonary nodule : Preparation for the medical specialist examination: part 145]. Internist (Berl) 2022; 63:259-263. [PMID: 35238984 DOI: 10.1007/s00108-022-01281-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/24/2022] [Indexed: 10/18/2022]
Affiliation(s)
- M Nunninger
- Klinik für Radiologie, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Deutschland
| | - G F Torsello
- Klinik für Radiologie, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Deutschland.
| |
Collapse
|
12
|
Bernardini G, Litterscheid S, Torsello GB, Torsello GF, Beropoulis E, Özdemir-van Brunschot D. A meta-analysis of safety and efficacy of endovascular aneurysm repair in aneurysm patients with severe angulated infrarenal neck. PLoS One 2022; 17:e0264327. [PMID: 35202427 PMCID: PMC8870420 DOI: 10.1371/journal.pone.0264327] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 02/08/2022] [Indexed: 11/18/2022] Open
Abstract
Objectives A growing number of abdominal aortic aneurysms with severe angulated neck anatomy is treated by endovascular means. However, contradictory early and late outcomes have been reported. Our review and outcome analysis attempted to evaluate the available literature and provide clinicians with a base for clinical implementation and future research. Materials and methods A systematic review of the literature was undertaken to identify the outcomes of endovascular aneurysm repair in patients with severe infrarenal neck angulation (SNA ≥ 60°) vs non-severe neck angulation (NSNA). Outcome measures included perioperative complications, type 1a endoleak, neck-related secondary procedures, stent graft migration, aneurysm rupture, increase (>5mm) in sac diameter, all-cause and aneurysm-related mortality (PROSPERO Nr.: CRD42021233253). Results Six observational studies reporting on 5981 patients (1457 with SNA and 4524 with NSNA) with a weighted mean follow-up period of 1.8 years were included. EVAR in SNA compared with NSNA was associated with a higher rate of type 1a endoleak at 30 days (4.0% vs 1.8%; p< 0.00001), at 1 year (2.8% vs 1.9%; p<0.03), at 2 years (4.9% vs 2.1%; p< 0.0002), at 3 years (5.6% vs 2.6%; p< 0.0001). The rate of neck-related secondary procedures was significantly higher at 1 year (6.6% vs 3.9%; p<0.05) and at 3 years (13.1% vs 9%; p<0.05). Graft migration, aneurysm sack increase, aneurysm rupture and all-cause mortality were not statistically different at mid-term. Conclusions The use of EVAR in severely angulated infrarenal aortic necks is associated with a high rate of early and mid-term complications. However, aortic related and all-causes mortality are not higher compared to patients with NSNA. Therefore, EVAR should be cautiously used in patients with SNA.
Collapse
Affiliation(s)
- Giulia Bernardini
- Department of Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Catania, Italy
- * E-mail:
| | - Sarah Litterscheid
- Institute for Vascular Research, St Franziskus Hospital, Münster, Germany
| | | | | | | | - Denise Özdemir-van Brunschot
- Department of Vascular and Endovascular Therapy, Augusta Hospital and Catholic Hospital Group, Düsseldorf, Germany
| |
Collapse
|
13
|
Bernardini G, Litterscheid S, Torsello GB, Torsello GF, Beropoulis E, Özdemir-van Brunschot D. A Meta Analysis of Safety and Efficacy of EVAR in Aneurysm Patients with Angulated and Hyperangulated Necks. EJVES Vasc Forum 2022. [DOI: 10.1016/j.ejvsvf.2021.12.072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
14
|
Fleckenstein FN, Roesel MJ, Krajewska M, Auer TA, Collettini F, Maleitzke T, Böning G, Torsello GF, Fehrenbach U, Gebauer B. Combining Transarterial Radioembolization (TARE) and CT-Guided High-Dose-Rate Interstitial Brachytherapy (CT-HDRBT): A Retrospective Analysis of Advanced Primary and Secondary Liver Tumor Treatment. Cancers (Basel) 2021; 14:cancers14010072. [PMID: 35008236 PMCID: PMC8750400 DOI: 10.3390/cancers14010072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/16/2021] [Accepted: 12/21/2021] [Indexed: 12/09/2022] Open
Abstract
Simple Summary Clinical management of advanced stages of primary and secondary liver tumors remains challenging. Combining different treatment approaches to create the most effective therapy for patients is, however, often necessary. With this study we aim to analyze the efficacy and safety of a combined intrahepatic treatment of transarterial radioembolization and CT-guided high-dose-rate interstitial brachytherapy. Our study showed that patients not responding to systemic chemotherapy or suffering from tumor relapse after surgical resection might benefit from a combined minimal-invasive treatment. Abstract Purpose: Treatment of patients with primary and secondary liver tumors remains challenging. This study analyzes the efficacy and safety of transarterial radioembolization (TARE) combined with CT-guided high-dose-rate interstitial brachytherapy (CT-HDRBT) for the treatment of primary and secondary liver tumors. Patients and Methods: A total of 77 patients (30 female) with various liver malignancies were treated. Primary endpoints were median overall survival (OS) and time to untreatable progression (TTUP). Additionally, subgroup analyses were performed in consideration of diagnosis and procedure sequence. Median OS and TTUP prediction were estimated using Kaplan–Meier analysis and hazard ratios (HR) were calculated using a multivariate Cox proportional hazard model. Results: A total of 115 CT-HDRBT and 96 TARE procedures were performed with no significant complications recorded. Median OS and TTUP were 29.8 (95% CI 18.1–41.4) and 23.8 (95% CI 9.6–37.9) months. Median OS for hepatocellular carcinoma (HCC)-, cholangiocarcinoma carcinoma (CCA) and colorectal cancer (CRC) patients was 29.8, 29.6 and 34.4 months. Patients starting with TARE had a median OS of 26.0 (95% CI 14.5–37.5) compared to 33.7 (95% CI 21.6–45.8) months for patients starting with CT-HDRBT. Hazard ratio of 1.094 per month was shown for patients starting with CT-HDRBT. Conclusion: Combining TARE and CT-HDRBT is effective and safe for the treatment of advanced stage primary and secondary liver tumors. Our data indicate that early TARE during the disease progression may have a positive effect on survival.
Collapse
Affiliation(s)
- Florian Nima Fleckenstein
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
- BIH Charité Clinician Scientist Program, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, 10178 Berlin, Germany;
- Correspondence: ; Tel.: +49-30-450-657297
| | - Maximilian Julius Roesel
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
| | - Maja Krajewska
- Institute of Biometry and Clinical Epidemiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117 Berlin, Germany;
| | - Timo Alexander Auer
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
- BIH Charité Clinician Scientist Program, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, 10178 Berlin, Germany;
| | - Federico Collettini
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
- BIH Charité Clinician Scientist Program, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, 10178 Berlin, Germany;
| | - Tazio Maleitzke
- BIH Charité Clinician Scientist Program, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, 10178 Berlin, Germany;
- Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany
- Julius Wolff Institute, Berlin Institute of Health at Charité-Universitätsmedizin Berlin, 13353 Berlin, Germany
| | - Georg Böning
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
| | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
| | - Uli Fehrenbach
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
| | - Bernhard Gebauer
- Department of Diagnostic and Interventional Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 13353 Berlin, Germany; (M.J.R.); (T.A.A.); (F.C.); (G.B.); (G.F.T.); (U.F.); (B.G.)
| |
Collapse
|
15
|
Özdemir-van Brunschot DMD, Torsello GB, Bernardini G, Litterscheid S, Torsello GF, Beropoulis E. Use of Chimney Technique Does Not Improve the Outcome of Endovascular Aneurysm Repair in Patients With a Hyperangulated and Short Proximal Aortic Neck. J Endovasc Ther 2021; 29:361-369. [PMID: 34622699 DOI: 10.1177/15266028211050315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE We hypothesized that extending the proximal landing zone with the chimney technique could be beneficial in patients with a hyperangulated proximal aortic neck, defined as more > 60 degrees. MATERIAL AND METHODS We retrospectively analyzed the outcome of prospectively collected data of patients treated by endovascular aneurysm repair (EVAR) for infrarenal aortic aneurysm with a hyperangulated proximal aortic neck. In all, 104 out of 130 patients were treated without (Group A) and 24 with the chimney endovascular aortic repair (ChEVAR, Group B). Primary outcome was technical and clinical success according to the reporting standards of the Society of Vascular Surgery. RESULTS The use of the chimney technique was associated with a significantly longer operation duration (167 vs. 93 min, p < .001), longer fluoroscopy time (44 vs.30 min, p = < .001), and larger amount of contrast medium used (149 vs. 127 ml, p = .03) but did not significantly improve technical (79.2% vs. 87.7%) and clinical success (54.2% vs. 68.9%). Aneurysm-related mortality was higher in group B (8.3% vs. = 0%, p < .001). Type IA endoleak was high in both groups at completion angiography (11.3% in Group A vs. 12.5% in Group B) and at follow-up (10.4% in Group A vs. 4.5% in Group B) without significant difference between the groups. CONCLUSIONS Our data did not show a benefit of the primary use of the chimney technique in patients with a hyperangulated and short neck, although more studies are required to support this conclusion. Other strategies or new technologies are required for improving EVAR results in aneurysm patients with severe angulated proximal and short neck.
Collapse
Affiliation(s)
| | | | - Giulia Bernardini
- Department of Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Catania, Italy
| | - Sarah Litterscheid
- Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany
| | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine, Berlin, Germany
| | | |
Collapse
|
16
|
Richter J, Lindner AK, Geisel D, Torsello GF, Martinez GE, Isner C, Schürmann D, Pfäfflin F, Orhun A, Manciulli T, Brunetti E. Treatment of a giant hepatic echinococcal cyst with percutaneous drainage and in vivo assessment of the protoscolicidal effect of praziquantel. Clin J Gastroenterol 2021; 14:888-892. [PMID: 33851365 PMCID: PMC8154811 DOI: 10.1007/s12328-021-01397-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 03/19/2021] [Indexed: 11/26/2022]
Abstract
Therapy choices for cystic echinococcisis (CE) are stage-specific: surgical, minimally invasive, medical or observation without intervention. PAIR (percutaneous aspiration, instillation of a scolicide, and re-aspiration) has been considered the treatment of choice for uncomplicated echinococcal liver cysts. However, PAIR carries the risk of toxic cholangitis or hypernatremia and that the cyst frequently refills with bile after withdrawing the catheter. We treated a patient with a giant CE 1 liver cyst with puncture drainage (PD) under albendazole coverage. Drainage enabled us to monitor the morphology of protoscolices under praziquantel (PZQ) co-medication. Protoscolices degenerated within 5 days of PZQ 50 mg/kg/d. The cyst cavity solidified with no evidence of reactivation or secondary spread. Percutaneous treatments can replace surgery in a significant number or cases with hepatic CE. PD allows to assess microscopically the viability of protoscolices under co-medication with PZQ-albendazole and to avoid the instillation of topical scolicides.
Collapse
Affiliation(s)
- Joachim Richter
- Institute of Tropical Medicine and International Health, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Augustenburgerplatz 1, 13353, Berlin, FR, Germany.
| | - Andreas Karl Lindner
- Institute of Tropical Medicine and International Health, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Augustenburgerplatz 1, 13353, Berlin, FR, Germany
| | - Dominik Geisel
- Department of Radiology, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Berlin, Germany
| | - Giovanni Federico Torsello
- Department of Radiology, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Berlin, Germany
| | - Gabriela Equihua Martinez
- Institute of Tropical Medicine and International Health, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Augustenburgerplatz 1, 13353, Berlin, FR, Germany
| | - Caroline Isner
- Department of Infectious Diseases and Pulmonary Medicine, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Berlin, Germany
| | - Dirk Schürmann
- Department of Infectious Diseases and Pulmonary Medicine, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Berlin, Germany
| | - Frieder Pfäfflin
- Department of Infectious Diseases and Pulmonary Medicine, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Berlin, Germany
| | - Arzu Orhun
- Department of Plastical and Reconstructive Surgery, Charité University Medicine, Berlin, Corporate Member of Free University and Humboldt University, Berlin, Germany
| | - Tommaso Manciulli
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University Hospital of Pavia, Pavia, Italy
| | - Enrico Brunetti
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University Hospital of Pavia, Pavia, Italy
- Department of Tropical and Infectious Diseases, IRCCS Policlinico San Matteo Foundation Hospital, Pavia, Italy
| |
Collapse
|
17
|
Puta B, Fazzini S, Torsello G, Pipitone MD, Austermann M, Beropoulis E, Torsello GF. Preliminary Clinical and Radiologic Outcome of Matched Patients with Thoracoabdominal Aortic Aneurysms Treated by Low-Profile vs Standard Profile Branched Aortic Endografts. Ann Vasc Surg 2021; 75:397-405. [PMID: 33556526 DOI: 10.1016/j.avsg.2021.01.095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 01/15/2021] [Accepted: 01/18/2021] [Indexed: 12/20/2022]
Abstract
BACKGROUND Durability of low-profile branched aortic stent-grafts (LPSG) in the treatment of patients with thoracoabdominal aortic aneurysms (TAAA) remains unclear. Objective of this study is to compare the outcomes of LPSG with standard profile branched aortic stent-grafts (SPSG). METHODS Between January 2016 and January 2020, 225 consecutive patients with TAAA were treated by branched endovascular aortic repair (BEVAR). Twenty-four patients who were treated with a LPSG were compared to 24 patients who received SPSG as a control group. Control patients were selected according to aneurysm size (maximum aneurysm diameter) and extension (Crawford classification) as well as availability of adequate preoperative and postoperative CT-angiograms at 24 months. The primary endpoint was ongoing clinical success defined as successful implantation and freedom from aneurysm- or procedure-related death, secondary intervention, type I or III endoleak, infection, thrombosis, aneurysm expansion or rupture and conversion. Secondary endpoints were radiological changes of the branched endograft (migration, shortening, scoliosis, lordosis, and fracture). RESULTS After a median follow-up of 22.6 (LPSG) and 26.2 months (SPSG), no significant difference was found in terms of technical success (100% in both groups), late mortality (4.2% vs 0%), aneurysm diameter increase (4.2% in both groups) and reinterventions (25% vs 37.5%). Infection, thrombosis, aneurysm expansion or rupture and conversion were not observed. Radiological analysis of aortic graft remodeling showed no fracture and no significant migration, shortening, scoliosis and lordosis of the LPSG (6.1 mm, 7.5 mm, 12.8° and 6.1°) compared to SPSG (3.9 mm, 5.1 mm, 7.9° and 5.6°) after 2 years. CONCLUSION The clinical and radiological findings of the present study showed no increased mortality and complications for the matched patients who underwent treatment with low-profile vs standard-profile BEVAR. This study provides preliminary evidence of safety and efficacy of low-profile branched endografts in patients with demanding iliac access vessels.
Collapse
Affiliation(s)
- Besjona Puta
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Stefano Fazzini
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany.
| | - Giovanni Torsello
- Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany
| | | | - Martin Austermann
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany
| | | | - Giovanni Federico Torsello
- Department of Radiology, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Münster, Germany
| |
Collapse
|
18
|
Beropoulis E, Fazzini S, Austermann M, Torsello GB, Damerau S, Torsello GF. Long-term Results of Thoracic Endovascular Aortic Repair Using a Low-Profile Stent-Graft. J Endovasc Ther 2020; 28:56-62. [PMID: 32942922 DOI: 10.1177/1526602820952416] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the long-term results associated with the Zenith Alpha thoracic stent-graft, which was designed to address challenging access vessel anatomy. MATERIALS AND METHODS A retrospective analysis was conducted of 44 consecutive patients (mean age 72.5±8.3 years; 25 men) treated in a single center between August 2010 and October 2014 with a minimum follow-up of 5 years in survivors. The Zenith Alpha thoracic stent-graft was used to treat thoracic aortic aneurysms (n=37), thoracoabdominal aortic aneurysm (n=5), or penetrating aortic ulcer (n=2). Ten patients (23%) were American Society of Anesthesiologists class IV, and 9 (20%) had nonelective procedures. Access vessel anatomy was demanding (mean minimum diameter 5.4 mm, tortuosity index 1.3). The primary endpoint at 5 years was ongoing clinical success (freedom from aneurysm-/procedure-related death, secondary intervention, type I or III endoleak, infection, thrombosis, aneurysm expansion, rupture, or conversion). Secondary endpoints were freedom from all-cause mortality, device migration, stent fractures, fabric erosions, endoleaks, neurological events, and access vessel complications. RESULTS The ongoing clinical success was 84% (37 of 44 patients) owing to 4 aneurysm-related deaths (9%), 3 type I or III endoleaks (1 in a deceased patient), and 1 aneurysm expansion without detectable endoleak. There were 3 access vessel complications (7%), and no postoperative neurological events. Migration was observed in 2 cases (5%). There were no stent fractures or fabric tears. CONCLUSION Despite the alterations in stent-graft design and material to reduce profile, the Zenith Alpha thoracic stent-graft showed favorable long-term results even in multimorbid patients with demanding iliac anatomy.
Collapse
Affiliation(s)
| | - Stefano Fazzini
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.,Vascular Surgery, La Sapienza University of Rome, Italy
| | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
| | | | - Sarah Damerau
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
| | - Giovanni Federico Torsello
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.,Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Germany
| |
Collapse
|
19
|
Torsello GF, Beropoulis E, Munaò R, Trimarchi S, Torsello GB, Austermann M. Outcomes of bridging stent grafts in fenestrated and branched endovascular aortic repair. J Vasc Surg 2020; 72:859-865. [DOI: 10.1016/j.jvs.2019.10.089] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Accepted: 10/24/2019] [Indexed: 11/29/2022]
|
20
|
Pohlan J, Kamel SN, Torsello GF, Zickler D, Kruse JM, Eckardt KU, Gebauer B. Successful aspiration thrombectomy in a patient with submassive, intermediate-risk pulmonary embolism following COVID-19 pneumonia. Radiol Case Rep 2020; 15:1764-1768. [PMID: 32774577 PMCID: PMC7365091 DOI: 10.1016/j.radcr.2020.07.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 07/11/2020] [Accepted: 07/11/2020] [Indexed: 01/23/2023] Open
Abstract
A 64-year-old female patient presented with severe dyspnea shortly after apparent recovery from COVID-19 disease. Chest computed tomography revealed central pulmonary embolism and ultrasonography showed a deep vein thrombosis of her right leg. The patient was tachycardiac with evidence of right ventricular strain on echocardiography. An interdisciplinary decision for interventional therapy was made. Angiographic aspiration thrombectomy resulted in a significant reduction of thrombus material and improved flow in the pulmonary arteries and immediate marked clinical improvement and subsequent normalization of functional echocardiographic parameters. This case adds to the emerging evidence for severe thromboembolic complications following COVID-19 and suggests aspiration thrombectomy can be considered in pulmonary embolism of intermediate risk.
Collapse
Affiliation(s)
- Julian Pohlan
- Department of Diagnostic and Interventional radiology, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Sarah Nadine Kamel
- Department of Nephrology and Medical Intensive Care, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional radiology, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Daniel Zickler
- Department of Nephrology and Medical Intensive Care, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Jan Matthias Kruse
- Department of Nephrology and Medical Intensive Care, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Kai-Uwe Eckardt
- Department of Nephrology and Medical Intensive Care, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Bernard Gebauer
- Department of Diagnostic and Interventional radiology, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| |
Collapse
|
21
|
Torsello GF, Argyriou A, Stavroulakis K, Bosiers MJ, Austermann M, Torsello GB. One-Year Results From the SURPASS Observational Registry of the CTAG Stent-Graft With the Active Control System. J Endovasc Ther 2020; 27:421-427. [PMID: 32193990 PMCID: PMC7288855 DOI: 10.1177/1526602820913007] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Purpose: To report the outcomes from the observational SURPASS
registry, which was created to assess the performance of the Conformable TAG
(CTAG) stent-graft with the Active Control System (ACS) in patients undergoing
thoracic endovascular aortic repair (TEVAR) in a real-world setting.
Materials and Methods: The SURPASS registry
(ClinicalTrials.gov; identifier NCT03286400) was an
observational, prospective, single-arm, post-market, international study that
enrolled patients undergoing TEVAR using the CTAG with ACS for both acute and
chronic thoracic aortic disease between October 2017 and July 2018. The CTAG
with ACS features 2-stage deployment of the stent-graft and an optional
angulation mechanism that modifies only the proximal end of the stent-graft.
During the observation period, 127 patients (mean age 67.1±12.1 years, range
27–86; 92 men) were enrolled and treated for an array of aortic pathologies,
including chronic and acute lesions and 4 ruptured descending thoracic
aneurysms. The primary outcome of this study was technical success; secondary
outcomes were clinical success and major adverse events at 30 days and 12
months. The numbers of 2-stage device deployments and applications of the
angulation mechanism were recorded, along with the reasons for use.
Results: Technical success of the TEVAR was 97.6% owing to
unintentional partial coverage of supra-aortic branches in 3 cases (the vessels
were patent on imaging). The stent-graft was repositioned at its intermediate
diameter in 79 patients (62.2%), and the angulation feature was applied in 64
cases (50.4%), mainly to improve proximal wall apposition and orthogonality in
the aorta. The desired effect was achieved in 60 cases (93.8%). There was no
device compression, bird-beak configuration, fracture, or graft occlusion. The
30-day and 12-month clinical success rates were 97.6% and 92.9%, respectively.
There were 3 aorta-related deaths at 30 days and a further 3 at 12 months.
Fatalities were due to a retrograde type A dissection (0.8%), paraplegia, bowel
ischemia, sepsis in the setting of a mycotic aneurysm, aneurysm rupture post
aortoesophageal fistula, and multiorgan dysfunction syndrome. Three endoleaks (2
type Ia and 1 type III) required reintervention. Conclusion: In the
SURPASS registry, the use of the CTAG device with ACS showed promising outcomes
despite the challenging pathologies. The new delivery system enables a
controlled staged delivery with in situ adjustments during positioning,
facilitating the treatment of complex aortic disease.
Collapse
Affiliation(s)
- Giovanni Federico Torsello
- Department of Vascular Surgery, St Franziskus Hospital Münster, University of Münster, Germany.,Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Germany
| | - Angeliki Argyriou
- Department of Vascular Surgery, St Franziskus Hospital Münster, University of Münster, Germany
| | | | - Michel J Bosiers
- Department of Vascular Surgery, St Franziskus Hospital Münster, University of Münster, Germany
| | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital Münster, University of Münster, Germany
| | - Giovanni B Torsello
- Department of Vascular Surgery, St Franziskus Hospital Münster, University of Münster, Germany
| | | |
Collapse
|
22
|
Torsello GF, Herten M, Müller M, Frank A, Torsello GB, Austermann M. Comparison of the Biomechanical Properties of the Advanta V12/iCast and Viabahn Stent-Grafts as Bridging Devices in Fenestrated Endografts: An In Vitro Study. J Endovasc Ther 2020; 27:258-265. [DOI: 10.1177/1526602820908602] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To compare experimentally the biomechanical properties of the Viabahn Balloon-Expandable Stent Graft (VBX) with the widely used Advanta V12/iCast in the role of bridging stent-grafts for fenestrated endovascular aortic repair. Materials and Methods: Test sheets made of polyester having 2 rows of 5 fenestrations in 6-mm and 8-mm diameters were used to simulate a commercially made fenestrated aortic endograft. In total, 40 stent-grafts measuring 6×39 mm and 8×39 mm (10 of each size for each stent-graft) were implanted in fenestration sheets immersed in a 37°C water bath. After flaring, all stent-grafts were evaluated using microscopy and radiography. Biomechanical evaluation included pullout and the shear stress force testing; results are reported in Newtons (N) as the median (minimum–maximum). Results: After flaring, no damage or fracture to the stent-graft structures were detected. Pullout forces for the 6-mm stent-grafts were 27.1 N (20.0–28.9) for the VBX and 16.6 N (14.7–19.2) for the Advanta (p=0.008). Pullout forces for the 8-mm stent-grafts were 20.1 N (14.8–21.5) for the VBX and 15.8 N (12.4–17.5) for the Advanta (p=0.095). The shear stress forces necessary to dislocate the device at 150% stent diameter displacement was 12.5 N (VBX) vs 14.7 N (Advanta) for the 6-mm devices and 23.3 N (VBX) vs 20.2 N (Advanta) for the 8-mm stents (p>0.99 and p=0.222, respectively). Conclusion: In vitro tests simulating external pull and shear forces on bridging stent-grafts implanted in fenestrations showed that the VBX had resistance to dislocation equivalent to a well-known control device.
Collapse
Affiliation(s)
- Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine, Berlin, Germany
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
| | - Monika Herten
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
- Department of Orthopedic and Trauma Surgery, Essen University Hospital, Essen, Germany
| | - Markus Müller
- Biomechanics Laboratory, Department for Hand, Trauma and Reconstructive Surgery, University Hospital, Münster, Germany
| | - André Frank
- Biomechanics Laboratory, Department for Hand, Trauma and Reconstructive Surgery, University Hospital, Münster, Germany
| | | | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
| |
Collapse
|
23
|
Fazzini S, Torsello GF, Austermann M, Torsello G. TAA 10. The Impact of Aortic Remodeling on the Performance of Bridging Stents After Branched Endovascular Aortic Repair. J Vasc Surg 2019. [DOI: 10.1016/j.jvs.2019.08.102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Taneva GT, Donas KP, Torsello GB, Seifarth H, de Azevedo FM, Austermann M, Torsello GF. In Vitro Evaluation of Balloon-Expandable Chimney Grafts in the Renal Arteries Combined With the Endurant Endograft. J Endovasc Ther 2019; 26:865-870. [DOI: 10.1177/1526602819872498] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To compare balloon-expandable covered stents (BECS) available for use as renal chimney grafts to the Advanta V12 approved for use with the Endurant endograft. Materials and Methods: A silicone model was manufactured based on preoperative computed tomography angiography (CTA) scans of a patient with a 7-cm juxtarenal aneurysm treated with an Endurant bifurcated endograft and an Advanta V12 covered stent for the 6-mm-diameter right renal artery. The model was placed in a flow box filled with a 37°C blood-mimicking solution equipped with a pulsatile pumping system (140/60 mm Hg). The tested BECS were the Advanta V12, the VBX, and the BeGraft+. A 36-mm-diameter Endurant II endograft with a 16-mm-diameter contralateral limb and a 6×59-mm BECS chimney graft were used in 9 consecutive tests (3 for each combination). After each implantation, the model was placed in the CT scanner, and 2 radiologists blinded to the test device independently measured the gutter areas and the patent chimney graft lumen at the level of the Endurant’s suprarenal stent, at the level of the chimney’s maximum curvature, and 10 mm inside the renal artery. The intraclass correlation coefficients (ICC) were calculated to assess interreader reliability. Results: The mean gutter areas were 19.3±7, 20.2±8, and 22.3±8 mm2 for the Advanta, VBX, and BeGraft+, respectively (all p>0.05). At the level of the aortic endograft’s suprarenal stent struts, the mean diameter of the Advanta V12, VBX, and BeGraft+ were 4.46±0.3, 4.12±0.4, and 4.12±0.3 mm, respectively (all p>0.05). At the level of the maximum chimney graft angulation, the mean diameters were 3.77±0.3, 4.16±0.1, and 3.74±0.3 mm, respectively (all p>0.05). In the right renal artery, the mean diameters were 3.91±0.2, 4.05±0.9, and 4.3±0.4 mm, respectively (all p>0.05). The ICCs varied between 0.7 and 0.9, indicating good agreement between readers. Conclusion: These in vitro findings showed comparable results between the Advanta V12 and the available BECS used in conjunction with the Endurant endograft according to the instructions for use. Further clinical evaluation is needed to confirm these results.
Collapse
Affiliation(s)
- Gergana T. Taneva
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
| | | | | | - Harald Seifarth
- Clinic for Diagnostic and Interventional Radiology, Klinikum Esslingen, Esslingen, Germany
| | | | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
| | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Germany
| |
Collapse
|
25
|
Torsello GF, Herten M, Frank A, Müller M, Jung S, Torsello GB, Austermann M. Performance of BeGraft and BeGraft+ Stent-Grafts as Bridging Devices for Fenestrated Endovascular Aneurysm Repair: An In Vitro Study. J Endovasc Ther 2019; 26:787-794. [PMID: 31379276 DOI: 10.1177/1526602819866435] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To investigate 2 generations of balloon-expandable covered stents as potential bridging devices using an in vitro model of stent-graft fenestrations. Materials and Methods: Twenty BeGraft and 20 BeGraft+ cobalt-chromium stents covered in expanded polytetrafluoroethylene (ePTFE) in 6- and 8-mm diameters were tested in sheets mimicking stent-graft fenestrations. Microscopy and radiography were employed to evaluate stent morphology after flaring. In vitro bench tests measured maximum pullout (perpendicular displacement) and the shear stress (axial displacement) forces needed to dislocate the stents. Results: No alteration of ePTFE coverage was detected in the flared stents. Digital radiography and computed tomography showed marked alteration of the stent geometry, which was more pronounced in the BeGraft group. No fractures were detected. Median (minimum-maximum) pullout forces for the 6-mm stent-grafts were 17.1 N (15.8-19.6) for the BeGraft device and 30.4 N (20.2-31.9) for the BeGraft+ device (p=0.006). Median (minimum-maximum) pullout forces for the 8-mm stent-grafts were 11.3 N (11-12.1) for the BeGraft device and 21.8 N (18.2-25.5) for the BeGraft+ device (p<0.001). The shear stress test showed median forces of 10.5 vs 15.28 N at 150% of the stent diameter for the 6-mm BeGraft and BeGraft+ stent-grafts, respectively, and 15.23 vs 20.72 N at 150% stent diameter for the 8-mm models (p=0.016 and 0.017, respectively). Conclusion: Flaring changed the stent geometry but did not provoke stent fractures. The BeGraft+ is superior to the BeGraft in terms of pullout and shear stress forces, demonstrating greater resilience.
Collapse
Affiliation(s)
- Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Germany.,Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
| | - Monika Herten
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany.,Department of Orthopedic and Trauma Surgery, Essen University Hospital, Essen, Germany
| | - André Frank
- Biomechanics Laboratory, Department for Hand, Trauma, and Reconstructive Surgery, University Hospital Münster, Germany
| | - Markus Müller
- Biomechanics Laboratory, Department for Hand, Trauma, and Reconstructive Surgery, University Hospital Münster, Germany
| | - Susanne Jung
- Department of Cranio-Maxillofacial Surgery, University Hospital Münster, Germany
| | | | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
| |
Collapse
|
26
|
Hahtapornsawan S, Lazaridis K, Criado FJ, Torsello GF, Bisdas T, Austermann M, Donas KP. CTA Assessment of Midterm Morphological Changes to Chimney Grafts Used in the Treatment of Juxtarenal Aortic Aneurysms. J Endovasc Ther 2019; 26:697-703. [PMID: 31282253 DOI: 10.1177/1526602819861747] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To evaluate chimney stent-graft position and morphological changes of the aneurysm sac as visualized by postoperative computed tomography angiography (CTA) over a minimum 24-month follow-up period. Materials and Methods: Twenty-one patients (mean age 75.7±8.6 years; 20 men) with juxtarenal aortic aneurysms who underwent successful chimney endovascular aneurysm repair (ch-EVAR) with the Endurant stent-graft and had 2 postoperative CTAs separated by at least 24 months were included in the study. CTA-based measurements of aortic stent-graft migration, target vessel angle, and chimney angle were compared between the serial scans. Results: During a mean follow-up of 34.9 months (range 24-69.2), the mean migration of the aortic stent-grafts was under 5 mm (2.76±2.4 mm). The average migration distance per year was 1.15 mm. The aneurysm diameter reduced a mean 3.25 mm (p=0.048). The right renal artery angle moved significantly upward 6.72° (p=0.025), while the right renal chimney stent-graft moved significantly downward 7.83° (p=0.042). The left renal artery angle also moved upward 1.87° (p=0.388) and the corresponding chimney moved downward 5.68° (p=0.133). During the study period, no type I/III endoleak or chimney occlusion was observed. Conclusion: Midterm morphometric assessment of ch-EVAR using CTA showed significant aneurysm sac shrinkage and a stable 3-year position of the abdominal devices, with the mean downward migration of the aortic stent-graft being <5 mm in the majority of cases. The chimney grafts seem to be prone to take an oblique rather than parallel configuration during follow-up. However, there was no relevant clinical consequence related to this phenomenon.
Collapse
Affiliation(s)
| | | | | | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charite Campus Virchow-Klinikum, Charite University Medicine Berlin, Germany
| | - Theodosios Bisdas
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
| | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany
| | | |
Collapse
|
27
|
Torsello GF, Herten M, Müller M, Frank A, Torsello GB, Austermann M. In Vitro Evaluation of the Gore Viabahn Balloon-Expandable Stent-Graft for Fenestrated Endovascular Aortic Repair. J Endovasc Ther 2019; 26:361-368. [DOI: 10.1177/1526602819842569] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose: To evaluate the safety and integrity of a new stent-graft as a potential bridging device in fenestrated stent-grafts using an in vitro fenestrated model. Materials and Methods: Polyester test sheets with ten 6-mm- or 8-mm-diameter fenestrations were used to simulate a fenestrated main body endoprosthesis. In total, 50 Viabahn balloon-expandable (VBX) stent-grafts of varying lengths (29 and 39 mm) and diameters (6, 7, and 8 mm) were implanted in the fitting fenestrations. After release, the 6- and 7-mm-diameter stent-grafts were flared with a 10×20-mm angioplasty balloon; a 12×20-mm balloon was used in the 8-mm-diameter devices. Safety of the devices was defined as absence of fractures detected on radiography or computed tomography (CT), as well as material failure detected by microscopy and water permeability testing. The forces (in Newtons, N) needed for perpendicular dislocation (pullout force) and axial dislocation (shear stress force) were also evaluated. Results: Forty VBX stent-grafts were subjected to digital radiographic imaging and multiplanar CT. None showed any stent fracture. Subsequent microscopy indicated no damage to the fabric or separation of the graft after flaring. Ten VBX stent-grafts underwent water permeability testing after flaring; no water passed through the graft wall during a 10-minute period under an intraluminal pressure at 120 mm Hg. Testing of 25 VBX stent-grafts revealed initial pullout forces between 11.3 and 31 N. Shear stress tests showed that the average force needed to dislocate the stent-grafts by 50% of their diameter ranged between 5.75 and 6.91 N (mean 6.1±0.5 N) for the 6-mm stents and between 3.31 and 5.4 N (mean 4.4±0.8) for the 8-mm stents. Conclusion: This preliminary study demonstrated the applicability of the VBX as a bridging stent-graft in a simulated fenestration model. A comparison with other stent-grafts and clinical assessment are required.
Collapse
Affiliation(s)
- Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine Berlin, Germany
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
| | - Monika Herten
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
- Department of Orthopedic and Trauma Surgery, Essen University Hospital, Essen, Germany
| | - Markus Müller
- Biomechanics Laboratory, Department for Hand, Trauma and Reconstructive Surgery, University Hospital Münster, Germany
| | - André- Frank
- Biomechanics Laboratory, Department for Hand, Trauma and Reconstructive Surgery, University Hospital Münster, Germany
| | | | - Martin Austermann
- Department of Vascular Surgery, St Franziskus Hospital Münster, Germany
| |
Collapse
|
28
|
Panuccio G, Torsello GF, Pfister M, Bisdas T, Bosiers MJ, Torsello G, Austermann M. Computer-aided endovascular aortic repair using fully automated two- and three-dimensional fusion imaging. J Vasc Surg 2016; 64:1587-1594.e1. [PMID: 27575809 DOI: 10.1016/j.jvs.2016.05.100] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2016] [Accepted: 05/29/2016] [Indexed: 12/20/2022]
Abstract
OBJECTIVE To assess the usability of a fully automated fusion imaging engine prototype, matching preinterventional computed tomography with intraoperative fluoroscopic angiography during endovascular aortic repair. METHODS From June 2014 to February 2015, all patients treated electively for abdominal and thoracoabdominal aneurysms were enrolled prospectively. Before each procedure, preoperative planning was performed with a fully automated fusion engine prototype based on computed tomography angiography, creating a mesh model of the aorta. In a second step, this three-dimensional dataset was registered with the two-dimensional intraoperative fluoroscopy. The main outcome measure was the applicability of the fully automated fusion engine. Secondary outcomes were freedom from failure of automatic segmentation or of the automatic registration as well as accuracy of the mesh model, measuring deviations from intraoperative angiography in millimeters, if applicable. RESULTS Twenty-five patients were enrolled in this study. The fusion imaging engine could be used in successfully 92% of the cases (n = 23). Freedom from failure of automatic segmentation was 44% (n = 11). The freedom from failure of the automatic registration was 76% (n = 19), the median error of the automatic registration process was 0 mm (interquartile range, 0-5 mm). CONCLUSIONS The fully automated fusion imaging engine was found to be applicable in most cases, albeit in several cases a fully automated data processing was not possible, requiring manual intervention. The accuracy of the automatic registration yielded excellent results and promises a useful and simple to use technology.
Collapse
Affiliation(s)
- Giuseppe Panuccio
- Department of Vascular Surgery, St. Franziskus Hospital and University Clinic of Muenster, Muenster, Germany.
| | - Giovanni Federico Torsello
- Department of Vascular Surgery, St. Franziskus Hospital and University Clinic of Muenster, Muenster, Germany; Westphalian Center for Radiology, Muenster, Germany
| | | | - Theodosios Bisdas
- Department of Vascular Surgery, St. Franziskus Hospital and University Clinic of Muenster, Muenster, Germany
| | - Michel J Bosiers
- Department of Vascular Surgery, St. Franziskus Hospital and University Clinic of Muenster, Muenster, Germany
| | - Giovanni Torsello
- Department of Vascular Surgery, St. Franziskus Hospital and University Clinic of Muenster, Muenster, Germany
| | - Martin Austermann
- Department of Vascular Surgery, St. Franziskus Hospital and University Clinic of Muenster, Muenster, Germany
| |
Collapse
|
29
|
Donas KP, Torsello G, Piccoli G, Pitoulias GA, Torsello GF, Bisdas T, Austermann MJ, Gasparini D. SS3. The PROTAGORAS Study to Evaluate the Performance of the Endurant Stent Graft for Patients With Pararenal Pathologies Treated by the Chimney/Snorkel Endovascular Technique. J Vasc Surg 2015. [DOI: 10.1016/j.jvs.2015.04.073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
30
|
Torsello GF, Torsello GB, Austermann M. Zenith TX2LowProfile TAA Endovascular Graft: a next generation thoracic stent-graft. J Cardiovasc Surg (Torino) 2012; 53:153-159. [PMID: 22456636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
AIM The aim of the present article is to describe a new thoracic stent graft (Zenith TX2 Low-Profile TAA Endovascular Graft). METHODS Feasibility of endovascular repair of thoracic aortic aneurysms depends on several anatomic factors. A primary limitation is an adequate arterial approach. Since most currently used endografts require large introducer sheaths, patients with severely diseased iliofemoral vessels are often excluded from this less-invasive technique. Attempts to overcome access difficulties increase the risk for arterial access-site complications such as aortoiliac rupture. In addition, highly angulated proximal landing zones provide challenges in obtaining proximal graft conformance and sealing. RESULTS The introduction of next-generation endografts such as the Zenith TX2LowProfile TAA Endovascular Graft provides a solution for a larger number of patients, including those with small vessels, vascular access problems and tortuous aortic anatomy. CONCLUSION The ongoing Zenith TX2 Low-Profile Endovascular Graft trial will build further understanding of the performance of the device allowing for treatment of a wider patient population.
Collapse
Affiliation(s)
- G F Torsello
- Department of Vascular Surgery, St. Franziskus Hospital, Münster, Germany.
| | | | | |
Collapse
|
31
|
Torsello G, Torsello GF. The need of a new training paradigm. J Cardiovasc Surg (Torino) 2011; 52:1-2. [PMID: 21224804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
|
32
|
Donas KP, Torsello GF. Endovascular surgery as a bridge solution for selected vascular emergencies. J Cardiovasc Surg (Torino) 2010; 51:337-342. [PMID: 20523283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Vascular emergencies patients present with several problems requiring immediate sufficient evaluation of the situation and intervention in order to save life, limb, or a serious health injury. Endovascular surgery may be very useful as bridging technique in order to obtain immediate bleeding control. Additionally, a remarkable number of patients has poor general health conditions and is unfit for open repair. The surgical solution would be invasive and prohibitive for this high-risk patient's subgroup. Endovascular techniques play an important role in the management of vascular emergencies. They allow treatment to be rapidly coupled with diagnosis, especially beneficial parameter for traumatic injuries. In particular, embolization is a well-established technique for hemostasis and is preferable when intervention for bleeding pelvic fractures is necessary. Additionally, in case of significant tissue destruction and contamination in the vicinity of the injury vascular access by endovascular techniques may be advantageous. Finally, endovascular balloon occlusion for vascular control may be used as an adjunct to surgery when conventional exposure is technically challenging and hazardous. The objectives of this review article are to highlight the utility of endovascular surgery in vascular emergencies and to compare current treatment options of urgent clinical entities, based on the literature.
Collapse
Affiliation(s)
- K P Donas
- Department of Vascular Surgery, St. Franziskus Hospital Münster, Münster, Germany.
| | | |
Collapse
|