1
|
Tzirakis K, Kontopodis N, Ioannou CV. A hemodynamic study of blood flow models on various stent graft configurations during aorto-iliac reconstruction. Clin Hemorheol Microcirc 2024; 87:199-219. [PMID: 38363603 DOI: 10.3233/ch-232058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
PURPOSE To compare the hemodynamic performance of three (Bottom Up non-ballet, Top-Down non-ballet, Top Down ballet) idealized stent graft configurations used during endovascular repair of abdominal aortic aneurysms, under the influence of various rheological models. METHODS Ten rheological models are assumed and a commercial finite volume solver is employed for the simulation of blood flow under realistic boundary conditions. An appropriate mesh convergence study is performed and five hemodynamic variables are computed: the time average wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), endothelial cell activation potential (ECAP) and displacement force (DF) for all three configurations. RESULTS The choice of blood flow model may affect results, but does not constitute a significant determinant on the overall performance of the assumed stent grafts. On the contrary, stent graft geometry has a major effect. Specifically, the Bottom Up non-ballet type is characterized by the least favorable performance presenting the lowest TAWSS and the highest OSI, RRT and ECAP values. On the other hand, the Top Down ballet type presents hemodynamic advantages yielding the highest TAWSS and lowest OSI, RRT and ECAP average values. Furthermore, the ballet type is characterized by the lowest DF, although differences observed are small and their clinical relevance uncertain. CONCLUSIONS The effect of the assumed rheological model on the overall performance of the grafts is not significant. It is thus relatively safe to claim that it is the type of stent graft that determines its overall performance rather than the adopted blood flow model.
Collapse
Affiliation(s)
- Konstantinos Tzirakis
- Department of Mechanical Engineering, School of Engineering, Hellenic Mediterranean University, Heraklion, Crete, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Department, Medical School, University of Crete, Heraklion, Crete, Greece
| | - Christos V Ioannou
- Vascular Surgery Department, Medical School, University of Crete, Heraklion, Crete, Greece
| |
Collapse
|
2
|
Tran K, Deslarzes-Dubuis C, DeGlise S, Kaladji A, Yang W, Marsden AL, Lee JT. Patient-specific computational flow simulation reveals significant differences in paravisceral aortic hemodynamics between fenestrated and branched endovascular aneurysm repair. JVS Vasc Sci 2023; 5:100183. [PMID: 38314201 PMCID: PMC10832507 DOI: 10.1016/j.jvssci.2023.100183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 11/10/2023] [Indexed: 02/06/2024] Open
Abstract
Background Endovascular aneurysm repair with four-vessel fenestrated endovascular aneurysm repair (fEVAR) or branched endovascular aneurysm repair (bEVAR) currently represent the forefront of minimally invasive complex aortic aneurysm repair. This study sought to use patient-specific computational flow simulation (CFS) to assess differences in postoperative hemodynamic effects associated with fEVAR vs bEVAR. Methods Patients from two institutions who underwent four-vessel fEVAR with the Cook Zenith Fenestrated platform and bEVAR with the Jotec E-xtra Design platform were retrospectively selected. Patients in both cohorts were treated for paravisceral and extent II, II, and V thoracoabdominal aortic aneurysms. Three-dimensional finite element volume meshes were created from preoperative and postoperative computed tomography scans. Boundary conditions were adjusted for body surface area, heart rate, and blood pressure. Pulsatile flow simulations were performed with equivalent boundary conditions between preoperative and postoperative states. Postoperative changes in hemodynamic parameters were compared between the fEVAR and bEVAR groups. Results Patient-specific CFS was performed on 20 patients (10 bEVAR, 10 fEVAR) with a total of 80 target vessels (40 renal, 20 celiac, 20 superior mesenteric artery stents). bEVAR was associated with a decrease in renal artery peak flow rate (-5.2% vs +2.0%; P < .0001) and peak pressure (-3.4 vs +0.1%; P < .0001) compared with fEVAR. Almost all renal arteries treated with bEVAR had a reduction in renal artery perfusion (n = 19 [95%]), compared with 35% (n = 7) treated with fEVAR. There were no significant differences in celiac or superior mesenteric artery perfusion metrics (P = .10-.27) between groups. Time-averaged wall shear stress in the paravisceral aorta and branches also varied significantly depending on endograft configuration, with bEVAR associated with large postoperative increases in renal artery (+47.5 vs +13.5%; P = .002) and aortic time-averaged wall shear stress (+200.1% vs -31.3%; P = .001) compared with fEVAR. Streamline analysis revealed areas of hemodynamic abnormalities associated with branched renal grafts which adopt a U-shaped geometry, which may explain the observed differences in postoperative changes in renal perfusion between bEVAR and fEVAR. Conclusions bEVAR may be associated with subtle decreases in renal perfusion and a large increase in aortic wall shear stress compared with fEVAR. CFS is a novel tool for quantifying and visualizing the unique patient-specific hemodynamic effect of different complex EVAR strategies. Clinical Relevance This study used patient-specific CFS to compare postoperative hemodynamic effects of four-vessel fenestrated endovascular aneurysm repair (fEVAR) and branched endovascular aneurysm repair (bEVAR) in patients with complex aortic aneurysms. The findings indicate that bEVAR may result in subtle reductions in renal artery perfusion and a significant increase in aortic wall shear stress compared with fEVAR. These differences are clinically relevant, providing insights for clinicians choosing between these approaches. Understanding the patient-specific hemodynamic effects of complex EVAR strategies, as revealed by CFS, can aid in future personalized treatment decisions, and potentially reduce postoperative complications in aortic aneurysm repair.
Collapse
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford Healthcare, Stanford, CA
| | | | - Sebastien DeGlise
- Division of Vascular Surgery, Lausanne University Hospital, Lausanne, Switzerland
| | - Adrien Kaladji
- Department of Vascular Surgery, University of Rennes, Paris, France
| | - Weiguang Yang
- Department of Mechanical Engineering, Stanford University, Stanford, CA
| | - Alison L Marsden
- Department of Mechanical Engineering, Stanford University, Stanford, CA
| | - Jason T Lee
- Division of Vascular Surgery, Stanford Healthcare, Stanford, CA
| |
Collapse
|
3
|
Dias-Neto M, Oliveira-Pinto J. We're Crossing a Turbulent Zone, Fasten Your Seatbelts! Eur J Vasc Endovasc Surg 2023; 66:652. [PMID: 37582421 DOI: 10.1016/j.ejvs.2023.08.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 07/28/2023] [Accepted: 08/09/2023] [Indexed: 08/17/2023]
Affiliation(s)
- Marina Dias-Neto
- UnIC@RISE, Department of Surgery and Physiology, Faculty of Medicine of the University of Porto, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário de São João, Porto, Portugal.
| | - José Oliveira-Pinto
- Department of Angiology and Vascular Surgery, Centro Hospitalar Universitário de São João, Porto, Portugal; Department of Angiology and Vascular Surgery, Centro Hospitalar De Trás-Os-Montes E Alto Douro, E.P.E, Vila Real, Portugal
| |
Collapse
|
4
|
Tran K, Kaladji A, Yang W, Marsden AL, Lee JT. Assessing Differences in Aortic Haemodynamics Between Two vs. Four Vessel Fenestrated Endovascular Aortic Repair using Patient Specific Computational Flow Simulation. Eur J Vasc Endovasc Surg 2023; 66:739-740. [PMID: 37536515 DOI: 10.1016/j.ejvs.2023.07.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 06/26/2023] [Accepted: 07/28/2023] [Indexed: 08/05/2023]
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford Health Care, Stanford, CA, USA.
| | - Adrien Kaladji
- Department of Vascular Surgery, University of Rennes, Paris, France
| | - Weiguang Yang
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Alison L Marsden
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Jason T Lee
- Division of Vascular Surgery, Stanford Health Care, Stanford, CA, USA
| |
Collapse
|
5
|
Tzirakis K, Kamarianakis Y, Kontopodis N, Ioannou CV. Selection of Bifurcated Grafts' Dimensions during Aorto-Iliac Vascular Reconstruction Based on Their Hemodynamic Performance. Bioengineering (Basel) 2023; 10:776. [PMID: 37508803 PMCID: PMC10376214 DOI: 10.3390/bioengineering10070776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 06/21/2023] [Accepted: 06/24/2023] [Indexed: 07/30/2023] Open
Abstract
During the vascular surgical reconstruction of aorto-iliac occlusive/aneurysmal disease, bifurcated grafts are used where vascular surgeons intra-operatively select the size and the relative lengths of the parent and daughter portions of the graft. Currently, clinical practice regarding the selection of the most favorable geometric configuration of the graft is an understudied research subject: decisions are solely based on the clinical experience of the operating surgeon. This manuscript aims to evaluate the hemodynamic performance of various diameters, D, of bifurcated aortic grafts and relate those with proximal/distal part length ratios (the angle φ between the limbs is used as a surrogate marker of the main body-to-limb length ratio) in order to provide insights regarding the effects of different geometries on the hemodynamic environment. To this end, a computationally intensive set of simulations is conducted, and the resulting data are analyzed with modern statistical regression tools. A negative curvilinear relationship of TAWSS with both φ and D is recorded. It is shown that the angle between limbs is a more important predictor for the variability of TAWSS, while the graft's diameter is an important determinant for the variability of OSI. Large percentages of the total graft area with TAWSS < 0.4 Pa, which correspond to thrombogenic stimulating environments, are only observed for large values of φ and D > 20 mm. This variable ranges from 10% (for the smallest values of φ and D) to 55% (for the largest φ and D values). Our findings suggest that grafts with the smallest possible angle between the limbs (i.e., smallest parent-to-daughter length ratio) present the most favorable hemodynamic performance, yielding the smallest percentage of total graft area under thrombogenic simulating environments. Similarly, grafts with the smallest acceptable diameter should be preferred for the same reason. Especially, grafts with diameters greater than 20 mm should be avoided, given the abrupt increase in estimated thrombogenic areas.
Collapse
Affiliation(s)
- Konstantinos Tzirakis
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Crete, Greece
| | - Yiannis Kamarianakis
- Data Science Group, Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, 70013 Heraklion, Crete, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Department, Medical School, University of Crete, 71003 Heraklion, Crete, Greece
| | - Christos V Ioannou
- Vascular Surgery Department, Medical School, University of Crete, 71003 Heraklion, Crete, Greece
| |
Collapse
|
6
|
Schwarz EL, Pegolotti L, Pfaller MR, Marsden AL. Beyond CFD: Emerging methodologies for predictive simulation in cardiovascular health and disease. BIOPHYSICS REVIEWS 2023; 4:011301. [PMID: 36686891 PMCID: PMC9846834 DOI: 10.1063/5.0109400] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 12/12/2022] [Indexed: 01/15/2023]
Abstract
Physics-based computational models of the cardiovascular system are increasingly used to simulate hemodynamics, tissue mechanics, and physiology in evolving healthy and diseased states. While predictive models using computational fluid dynamics (CFD) originated primarily for use in surgical planning, their application now extends well beyond this purpose. In this review, we describe an increasingly wide range of modeling applications aimed at uncovering fundamental mechanisms of disease progression and development, performing model-guided design, and generating testable hypotheses to drive targeted experiments. Increasingly, models are incorporating multiple physical processes spanning a wide range of time and length scales in the heart and vasculature. With these expanded capabilities, clinical adoption of patient-specific modeling in congenital and acquired cardiovascular disease is also increasing, impacting clinical care and treatment decisions in complex congenital heart disease, coronary artery disease, vascular surgery, pulmonary artery disease, and medical device design. In support of these efforts, we discuss recent advances in modeling methodology, which are most impactful when driven by clinical needs. We describe pivotal recent developments in image processing, fluid-structure interaction, modeling under uncertainty, and reduced order modeling to enable simulations in clinically relevant timeframes. In all these areas, we argue that traditional CFD alone is insufficient to tackle increasingly complex clinical and biological problems across scales and systems. Rather, CFD should be coupled with appropriate multiscale biological, physical, and physiological models needed to produce comprehensive, impactful models of mechanobiological systems and complex clinical scenarios. With this perspective, we finally outline open problems and future challenges in the field.
Collapse
Affiliation(s)
- Erica L. Schwarz
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| | - Luca Pegolotti
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| | - Martin R. Pfaller
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| | - Alison L. Marsden
- Departments of Pediatrics and Bioengineering, Stanford University, Stanford, California 94305, USA
| |
Collapse
|
7
|
Three-Dimensional Geometric Analysis of Balloon-Expandable Covered Stents Improves Classification of Complications after Fenestrated Endovascular Aneurysm Repair. J Clin Med 2022; 11:jcm11195716. [PMID: 36233579 PMCID: PMC9572703 DOI: 10.3390/jcm11195716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 09/21/2022] [Accepted: 09/24/2022] [Indexed: 11/23/2022] Open
Abstract
In balloon-expandable covered stent (BECS) associated complications after fenestrated endovascular aneurysm repair (FEVAR), geometric analysis may determine the cause of failure and influence reintervention strategies. This study retrospectively classifies BECS-associated complications based on computed tomographic angiography (CTA) applied geometric analysis. BECS-associated complications of FEVAR-patients treated in two large vascular centers between 2012 and 2021 were included. The post-FEVAR CTA scans of complicated Advanta V12 BECSs were analyzed geometrically and complications were classified according to its location in the BECS. BECS fractures were classified according to an existing classification system. In 279 FEVAR-patients, 34 out of the 683 included Advanta V12 BECS (5%) presented with a complication. Two Advanta V12 complications occurred during the FEVAR procedure and 32 occurred during follow-up of which five post-FEVAR CTA scans were missing or not suitable for analysis. In the remaining 27 BECSs complications were classified as (endoleaks (n = 8), stenoses (n = 4), occlusions (n = 6), fractures (n = 3), and a combination of complications (n = 6)). All BECSs associated complications after FEVAR with available follow up CTA scans could be classified. Geometric analysis of BECS failure post-FEVAR can help to plan the reintervention strategy.
Collapse
|
8
|
Tran K, Feliciano KB, Yang W, Schwarz EL, Marsden AL, Dalman RL, Lee JT. Patient-specific changes in aortic hemodynamics is associated with thrombotic risk after fenestrated endovascular aneurysm repair with large diameter endografts. JVS Vasc Sci 2022; 3:219-231. [PMID: 35647564 PMCID: PMC9133635 DOI: 10.1016/j.jvssci.2022.04.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 04/06/2022] [Indexed: 12/24/2022] Open
Abstract
Background The durability of fenestrated endovascular aneurysm repair (fEVAR) has been threatened by thrombotic complications. In the present study, we used patient-specific computational fluid dynamic (CFD) simulation to investigate the effect of the endograft diameter on hemodynamics after fEVAR and explore the hypothesis that diameter-dependent alterations in aortic hemodynamics can predict for thrombotic events. Methods A single-institutional retrospective study was performed of patients who had undergone fEVAR for juxtarenal aortic aneurysms. The patients were stratified into large diameter (34-36 mm) and small diameter (24-26 mm) endograft groups. Patient-specific CFD simulations were performed using three-dimensional paravisceral aortic models created from computed tomographic images with allometrically scaled boundary conditions. Aortic time-averaged wall shear stress (TAWSS) and residence time (RT) were computed and correlated with future thrombotic complications (eg, renal stent occlusion, development of significant intraluminal graft thrombus). Results A total of 36 patients (14 with a small endograft and 22 with a large endograft) were included in the present study. The patients treated with large endografts had experienced a higher incidence of thrombotic complications compared with small endografts (45.5% vs 7.1%; P = .016). Large endografts were associated with a lower postoperative aortic TAWSS (1.45 ± 0.76 dynes/cm2 vs 3.16 ± 1.24 dynes/cm2; P < .001) and longer aortic RT (0.78 ± 0.30 second vs 0.34 ± 0.08 second; P < .001). In the large endograft group, a reduction >0.39 dynes/cm2 in aortic TAWSS demonstrated discriminatory power for thrombotic complications (area under the receiver operating characteristic curve, 0.77). An increased aortic RT of ≥0.05 second had similar accuracy for predicting thrombotic complications (area under the receiver operating characteristic curve, 0.78). The odds of thrombotic complications were significantly higher if patients had met the hemodynamic threshold changes in aortic TAWSS (odds ratio, 7.0; 95% confidence interval, 1.1-45.9) and RT (odds ratio, 8.0; 95% confidence interval, 1.13-56.8). Conclusions Patient-specific CFD simulation of fEVAR in juxtarenal aortic aneurysms demonstrated significant endograft diameter-dependent differences in aortic hemodynamics. A postoperative reduction in TAWSS and an increased RT correlated with future thrombotic events after large-diameter endograft implantation. Patient-specific simulation of hemodynamics provides a novel method for thrombotic risk stratification after fEVAR. The durability of fenestrated endovascular aneurysm repair (fEVAR) has been threatened by thrombotic complications. Using patient-specific computational flow simulation, the present retrospective study of 36 patients with juxtarenal aortic aneurysms treated with fEVAR identified several endograft diameter-dependent changes in aortic hemodynamics associated with thrombotic complications. A postoperative reduction in aortic wall shear stress and increased particle residence time correlated with the development of intraluminal graft thrombus and renal stent occlusion in patients treated with large diameter (>34 mm) endografts. These computationally estimated hemodynamic parameters could provide a novel method for patient-specific risk stratification for adverse events after fEVAR.
Collapse
Affiliation(s)
- Kenneth Tran
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
- Correspondence: Kenneth Tran, MD, Department of Vascular Surgery, Stanford University School of Medicine, 300 Pasteur Dr, Ste H3600, Stanford, CA 94305-5851
| | - K. Brennan Feliciano
- Department of Bioengineering, Stanford University School of Medicine, Stanford, CA
| | - Weiguang Yang
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, CA
| | - Erica L. Schwarz
- Department of Bioengineering, Stanford University School of Medicine, Stanford, CA
| | - Alison L. Marsden
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
- Department of Bioengineering, Stanford University School of Medicine, Stanford, CA
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Stanford, CA
| | - Ronald L. Dalman
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
| | - Jason T. Lee
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
- Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA
| |
Collapse
|