1
|
Tazza F, Boffa G, Schiavi S, Lapucci C, Piredda GF, Cipriano E, Zacà D, Roccatagliata L, Hilbert T, Kober T, Inglese M, Costagli M. Multiparametric Characterization and Spatial Distribution of Different MS Lesion Phenotypes. AJNR Am J Neuroradiol 2024; 45:1166-1174. [PMID: 38816021 PMCID: PMC11383400 DOI: 10.3174/ajnr.a8271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/01/2024] [Indexed: 06/01/2024]
Abstract
BACKGROUND AND PURPOSE MS lesions exhibit varying degrees of axonal and myelin damage. A comprehensive description of lesion phenotypes could contribute to an improved radiologic evaluation of smoldering inflammation and remyelination processes. This study aimed to identify in vivo distinct MS lesion types using quantitative susceptibility mapping and susceptibility mapping-weighted imaging and to characterize them through T1-relaxometry, myelin mapping, and diffusion MR imaging. The spatial distribution of lesion phenotypes in relation to ventricular CSF was investigated. MATERIALS AND METHODS MS lesions of 53 individuals were categorized into iso- or hypointense lesions, hyperintense lesions, and paramagnetic rim lesions, on the basis of their appearance on quantitative susceptibility mapping alone, according to published criteria, and with the additional support of susceptibility mapping-weighted imaging. Susceptibility values, T1-relaxation times, myelin and free water fractions, intracellular volume fraction, and the orientation dispersion index were compared among lesion phenotypes. The distance of the geometric center of each lesion from the ventricular CSF was calculated. RESULTS Eight hundred ninety-six MS lesions underwent the categorization process using quantitative susceptibility mapping and susceptibility mapping-weighted imaging. The novel use of susceptibility mapping-weighted images, which revealed additional microvasculature details, led us to re-allocate several lesions to different categories, resulting in a 35.6% decrease in the number of paramagnetic rim lesions, a 22.5% decrease in hyperintense lesions, and a 17.2% increase in iso- or hypointense lesions, with respect to the categorization based on quantitative susceptibility mapping only. The outcome of the categorization based on the joint use of quantitative susceptibility mapping and susceptibility mapping-weighted imaging was that 44.4% of lesions were iso- or hypointense lesions, 47.9% were hyperintense lesions, and 7.7% were paramagnetic rim lesions. A worsening gradient was observed from iso- or hypointense lesions to hyperintense lesions to paramagnetic rim lesions in T1-relaxation times, myelin water fraction, free water fraction, and intracellular volume fraction. Paramagnetic rim lesions were located closer to ventricular CSF than iso- or hypointense lesions. The volume of hyperintense lesions was associated with a more severe disease course. CONCLUSIONS Quantitative susceptibility mapping and susceptibility mapping-weighted imaging allow in vivo classification of MS lesions into different phenotypes, characterized by different levels of axonal and myelin loss and spatial distribution. Hyperintense lesions and paramagnetic rim lesions, which have the most severe microstructural damage, were more often observed in the periventricular WM and were associated with a more severe disease course.
Collapse
Affiliation(s)
- Francesco Tazza
- From the Departments of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (F.T., G.B., S.S., E.C., M.I., M.C.), University of Genoa, Genoa, Italy
| | - Giacomo Boffa
- From the Departments of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (F.T., G.B., S.S., E.C., M.I., M.C.), University of Genoa, Genoa, Italy
| | - Simona Schiavi
- From the Departments of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (F.T., G.B., S.S., E.C., M.I., M.C.), University of Genoa, Genoa, Italy
| | - Caterina Lapucci
- Istituto di Ricovero e Cura a Carattere Scientifico (C.L., L.R., M.I., M.C.), Ospedale Policlinico San Martino, Genoa, Italy
| | - Gian Franco Piredda
- Advanced Clinical Imaging Technology (G.F.P., T.H., T.K.), Siemens Healthineers International AG, Lausanne, Switzerland
| | - Emilio Cipriano
- From the Departments of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (F.T., G.B., S.S., E.C., M.I., M.C.), University of Genoa, Genoa, Italy
| | | | - Luca Roccatagliata
- Istituto di Ricovero e Cura a Carattere Scientifico (C.L., L.R., M.I., M.C.), Ospedale Policlinico San Martino, Genoa, Italy
- Department of Health Sciences (L.R.), University of Genoa, Genoa, Italy
| | - Tom Hilbert
- Advanced Clinical Imaging Technology (G.F.P., T.H., T.K.), Siemens Healthineers International AG, Lausanne, Switzerland
- Department of Radiology (T.H., T.K.), Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5 (T.H., T.K.), École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tobias Kober
- Advanced Clinical Imaging Technology (G.F.P., T.H., T.K.), Siemens Healthineers International AG, Lausanne, Switzerland
- Department of Radiology (T.H., T.K.), Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5 (T.H., T.K.), École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Matilde Inglese
- From the Departments of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (F.T., G.B., S.S., E.C., M.I., M.C.), University of Genoa, Genoa, Italy
- Istituto di Ricovero e Cura a Carattere Scientifico (C.L., L.R., M.I., M.C.), Ospedale Policlinico San Martino, Genoa, Italy
| | - Mauro Costagli
- From the Departments of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (F.T., G.B., S.S., E.C., M.I., M.C.), University of Genoa, Genoa, Italy
- Istituto di Ricovero e Cura a Carattere Scientifico (C.L., L.R., M.I., M.C.), Ospedale Policlinico San Martino, Genoa, Italy
| |
Collapse
|
2
|
Canales-Rodríguez EJ, Pizzolato M, Zhou FL, Barakovic M, Thiran JP, Jones DK, Parker GJM, Dyrby TB. Pore size estimation in axon-mimicking microfibers with diffusion-relaxation MRI. Magn Reson Med 2024; 91:2579-2596. [PMID: 38192108 DOI: 10.1002/mrm.29991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 12/04/2023] [Accepted: 12/12/2023] [Indexed: 01/10/2024]
Abstract
PURPOSE This study aims to evaluate two distinct approaches for fiber radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfiber phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. THEORY AND METHODS A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from scanning electron microscope images. RESULTS Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, although some discrepancies were observed. The spherical mean power-law method overestimated fiber radii. Conversely, the T2-based method exhibited higher sensitivity to smaller fiber radii, but faced limitations in accurately estimating the radius in one particular phantom, possibly because of material-specific relaxation changes. CONCLUSION The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibers. The T2-based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients, but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fiber radius estimation, highlights the advantages and limitations of both methods, and provides datasets for reproducible research.
Collapse
Affiliation(s)
- Erick J Canales-Rodríguez
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
| | - Marco Pizzolato
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
- Department of Applied Mathematics and Computer Science, Technical University of Denmark (DTU), Kongens Lyngby, Denmark
| | - Feng-Lei Zhou
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London (UCL), London, UK
- MicroPhantoms Limited, Cambridge, UK
| | - Muhamed Barakovic
- Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland
| | - Jean-Philippe Thiran
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
- Centre d'Imagerie Biomédicale (CIBM), EPFL, Lausanne, Switzerland
| | - Derek K Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, UK
| | - Geoffrey J M Parker
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London (UCL), London, UK
- Department of Neuroinflammation, Queen Square Institute of Neurology, University College London (UCL), London, UK
- Bioxydyn Limited, Manchester, UK
| | - Tim B Dyrby
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
- Department of Applied Mathematics and Computer Science, Technical University of Denmark (DTU), Kongens Lyngby, Denmark
| |
Collapse
|
3
|
Vasylechko SD, Warfield SK, Kurugol S, Afacan O. Improved myelin water fraction mapping with deep neural networks using synthetically generated 3D data. Med Image Anal 2024; 91:102966. [PMID: 37844473 PMCID: PMC10847969 DOI: 10.1016/j.media.2023.102966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 07/14/2023] [Accepted: 09/11/2023] [Indexed: 10/18/2023]
Abstract
We introduce a generative model for synthesis of large scale 3D datasets for quantitative parameter mapping of myelin water fraction (MWF). Our model combines a MR physics signal decay model with an accurate probabilistic multi-component parametric T2 model. We synthetically generate a wide variety of high quality signals and corresponding parameters from a wide range of naturally occurring prior parameter values. To capture spatial variation, the generative signal decay model is combined with a generative spatial model conditioned on generic tissue segmentations. Synthesized 3D datasets can be used to train any convolutional neural network (CNN) based architecture for MWF estimation. Our source code is available at: https://github.com/quin-med-harvard-edu/synthmap Reduction of acquisition time at the expense of lower SNR, as well as accuracy and repeatability of MWF estimation techniques, are key factors that affect the adoption of MWF mapping in clinical practice. We demonstrate that the synthetically trained CNN provides superior accuracy over the competing methods under the constraints of naturally occurring noise levels as well as on the synthetically generated images at low SNR levels. Normalized root mean squared error (nRMSE) is less than 7% on synthetic data, which is significantly lower than competing methods. Additionally, the proposed method yields a coefficient of variation (CoV) that is at least 4x better than the competing method on intra-session test-retest reference dataset.
Collapse
Affiliation(s)
- Serge Didenko Vasylechko
- Computational Radiology Laboratory, Boston Children's Hospital, Boston 02115, MA, USA; Harvard Medical School, Boston 02115, MA, USA.
| | - Simon K Warfield
- Computational Radiology Laboratory, Boston Children's Hospital, Boston 02115, MA, USA; Harvard Medical School, Boston 02115, MA, USA
| | - Sila Kurugol
- Computational Radiology Laboratory, Boston Children's Hospital, Boston 02115, MA, USA; Harvard Medical School, Boston 02115, MA, USA
| | - Onur Afacan
- Computational Radiology Laboratory, Boston Children's Hospital, Boston 02115, MA, USA; Harvard Medical School, Boston 02115, MA, USA
| |
Collapse
|
4
|
Rossi GMC, Mackowiak ALC, Açikgöz BC, Pierzchała K, Kober T, Hilbert T, Bastiaansen JAM. SPARCQ: A new approach for fat fraction mapping using asymmetries in the phase-cycled balanced SSFP signal profile. Magn Reson Med 2023; 90:2348-2361. [PMID: 37496187 DOI: 10.1002/mrm.29813] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 06/19/2023] [Accepted: 07/12/2023] [Indexed: 07/28/2023]
Abstract
PURPOSE To develop SPARCQ (Signal Profile Asymmetries for Rapid Compartment Quantification), a novel approach to quantify fat fraction (FF) using asymmetries in the phase-cycled balanced SSFP (bSSFP) profile. METHODS SPARCQ uses phase-cycling to obtain bSSFP frequency profiles, which display asymmetries in the presence of fat and water at certain TRs. For each voxel, the measured signal profile is decomposed into a weighted sum of simulated profiles via multi-compartment dictionary matching. Each dictionary entry represents a single-compartment bSSFP profile with a specific off-resonance frequency and relaxation time ratio. Using the results of dictionary matching, the fractions of the different off-resonance components are extracted for each voxel, generating quantitative maps of water and FF and banding-artifact-free images for the entire image volume. SPARCQ was validated using simulations, experiments in a water-fat phantom and in knees of healthy volunteers. Experimental results were compared with reference proton density FFs obtained with 1 H-MRS (phantoms) and with multiecho gradient-echo MRI (phantoms and volunteers). SPARCQ repeatability was evaluated in six scan-rescan experiments. RESULTS Simulations showed that FF quantification is accurate and robust for SNRs greater than 20. Phantom experiments demonstrated good agreement between SPARCQ and gold standard FFs. In volunteers, banding-artifact-free quantitative maps and water-fat-separated images obtained with SPARCQ and ME-GRE demonstrated the expected contrast between fatty and non-fatty tissues. The coefficient of repeatability of SPARCQ FF was 0.0512. CONCLUSION SPARCQ demonstrates potential for fat quantification using asymmetries in bSSFP profiles and may be a promising alternative to conventional FF quantification techniques.
Collapse
Affiliation(s)
- Giulia M C Rossi
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Adèle L C Mackowiak
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Berk Can Açikgöz
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Katarzyna Pierzchała
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Tobias Kober
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Tom Hilbert
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Jessica A M Bastiaansen
- Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Translational Imaging Center, Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| |
Collapse
|
5
|
Barakovic M, Pizzolato M, Tax CMW, Rudrapatna U, Magon S, Dyrby TB, Granziera C, Thiran JP, Jones DK, Canales-Rodríguez EJ. Estimating axon radius using diffusion-relaxation MRI: calibrating a surface-based relaxation model with histology. Front Neurosci 2023; 17:1209521. [PMID: 37638307 PMCID: PMC10457121 DOI: 10.3389/fnins.2023.1209521] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 07/24/2023] [Indexed: 08/29/2023] Open
Abstract
Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit of dMRI signals even when using the most advanced human MRI scanners. Therefore, new MRI methods that are sensitive to small axon radii are needed. In this proof-of-concept investigation, we examine whether a surface-based axonal relaxation process could mediate a relationship between intra-axonal T2 and T1 times and inner axon radius, as measured using postmortem histology. A unique in vivo human diffusion-T1-T2 relaxation dataset was acquired on a 3T MRI scanner with ultra-strong diffusion gradients, using a strong diffusion-weighting (i.e., b = 6,000 s/mm2) and multiple inversion and echo times. A second reduced diffusion-T2 dataset was collected at various echo times to evaluate the model further. The intra-axonal relaxation times were estimated by fitting a diffusion-relaxation model to the orientation-averaged spherical mean signals. Our analysis revealed that the proposed surface-based relaxation model effectively explains the relationship between the estimated relaxation times and the histological axon radius measured in various corpus callosum regions. Using these histological values, we developed a novel calibration approach to predict axon radius in other areas of the corpus callosum. Notably, the predicted radii and those determined from histological measurements were in close agreement.
Collapse
Affiliation(s)
- Muhamed Barakovic
- Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland
- Department of Neurology, University Hospital Basel, Basel, Switzerland
- Cardiff University Brain Research Imaging Centre, Cardiff University, Cardiff, Wales, United Kingdom
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Roche Pharma Research and Early Development, Neuroscience and Rare Diseases, Roche Innovation Center, Basel, Switzerland
| | - Marco Pizzolato
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Chantal M. W. Tax
- Cardiff University Brain Research Imaging Centre, Cardiff University, Cardiff, Wales, United Kingdom
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, Netherlands
| | - Umesh Rudrapatna
- Cardiff University Brain Research Imaging Centre, Cardiff University, Cardiff, Wales, United Kingdom
| | - Stefano Magon
- Roche Pharma Research and Early Development, Neuroscience and Rare Diseases, Roche Innovation Center, Basel, Switzerland
| | - Tim B. Dyrby
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
| | - Cristina Granziera
- Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland
- Department of Neurology, University Hospital Basel, Basel, Switzerland
- Research Center for Clinical Neuroimmunology and Neuroscience Basel (RC2NB), University Hospital Basel and University of Basel, Basel, Switzerland
| | - Jean-Philippe Thiran
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
- Centre d’Imagerie Biomédicale (CIBM), EPFL, Lausanne, Switzerland
| | - Derek K. Jones
- Cardiff University Brain Research Imaging Centre, Cardiff University, Cardiff, Wales, United Kingdom
| | - Erick J. Canales-Rodríguez
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| |
Collapse
|
6
|
Endt S, Engel M, Naldi E, Assereto R, Molendowska M, Mueller L, Mayrink Verdun C, Pirkl CM, Palombo M, Jones DK, Menzel MI. In Vivo Myelin Water Quantification Using Diffusion-Relaxation Correlation MRI: A Comparison of 1D and 2D Methods. APPLIED MAGNETIC RESONANCE 2023; 54:1571-1588. [PMID: 38037641 PMCID: PMC10682074 DOI: 10.1007/s00723-023-01584-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/18/2023] [Accepted: 07/25/2023] [Indexed: 12/02/2023]
Abstract
Multidimensional Magnetic Resonance Imaging (MRI) is a versatile tool for microstructure mapping. We use a diffusion weighted inversion recovery spin echo (DW-IR-SE) sequence with spiral readouts at ultra-strong gradients to acquire a rich diffusion-relaxation data set with sensitivity to myelin water. We reconstruct 1D and 2D spectra with a two-step convex optimization approach and investigate a variety of multidimensional MRI methods, including 1D multi-component relaxometry, 1D multi-component diffusometry, 2D relaxation correlation imaging, and 2D diffusion-relaxation correlation spectroscopic imaging (DR-CSI), in terms of their potential to quantify tissue microstructure, including the myelin water fraction (MWF). We observe a distinct spectral peak that we attribute to myelin water in multi-component T1 relaxometry, T1-T2 correlation, T1-D correlation, and T2-D correlation imaging. Due to lower achievable echo times compared to diffusometry, MWF maps from relaxometry have higher quality. Whilst 1D multi-component T1 data allows much faster myelin mapping, 2D approaches could offer unique insights into tissue microstructure and especially myelin diffusion.
Collapse
Affiliation(s)
- Sebastian Endt
- Technical University of Munich, Munich, Germany
- AImotion Bavaria, Technische Hochschule Ingolstadt, Ingolstadt, Germany
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
| | - Maria Engel
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
| | - Emanuele Naldi
- Technische Universität Braunschweig, Braunschweig, Germany
| | | | - Malwina Molendowska
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
- Medical Radiation Physics, Lund University, Lund, Sweden
| | - Lars Mueller
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | - Claudio Mayrink Verdun
- Technical University of Munich, Munich, Germany
- Munich Center for Machine Learning, Munich, Germany
| | | | - Marco Palombo
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
| | - Derek K. Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
| | - Marion I. Menzel
- Technical University of Munich, Munich, Germany
- AImotion Bavaria, Technische Hochschule Ingolstadt, Ingolstadt, Germany
- GE HealthCare, Munich, Germany
| |
Collapse
|
7
|
Villarreal-Haro JL, Gardier R, Canales-Rodríguez EJ, Fischi-Gomez E, Girard G, Thiran JP, Rafael-Patiño J. CACTUS: a computational framework for generating realistic white matter microstructure substrates. Front Neuroinform 2023; 17:1208073. [PMID: 37603781 PMCID: PMC10434236 DOI: 10.3389/fninf.2023.1208073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/13/2023] [Indexed: 08/23/2023] Open
Abstract
Monte-Carlo diffusion simulations are a powerful tool for validating tissue microstructure models by generating synthetic diffusion-weighted magnetic resonance images (DW-MRI) in controlled environments. This is fundamental for understanding the link between micrometre-scale tissue properties and DW-MRI signals measured at the millimetre-scale, optimizing acquisition protocols to target microstructure properties of interest, and exploring the robustness and accuracy of estimation methods. However, accurate simulations require substrates that reflect the main microstructural features of the studied tissue. To address this challenge, we introduce a novel computational workflow, CACTUS (Computational Axonal Configurator for Tailored and Ultradense Substrates), for generating synthetic white matter substrates. Our approach allows constructing substrates with higher packing density than existing methods, up to 95% intra-axonal volume fraction, and larger voxel sizes of up to 500μm3 with rich fibre complexity. CACTUS generates bundles with angular dispersion, bundle crossings, and variations along the fibres of their inner and outer radii and g-ratio. We achieve this by introducing a novel global cost function and a fibre radial growth approach that allows substrates to match predefined targeted characteristics and mirror those reported in histological studies. CACTUS improves the development of complex synthetic substrates, paving the way for future applications in microstructure imaging.
Collapse
Affiliation(s)
- Juan Luis Villarreal-Haro
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
| | - Remy Gardier
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
| | - Erick J. Canales-Rodríguez
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
| | - Elda Fischi-Gomez
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| | - Gabriel Girard
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
- Department of Computer Science, University of Sherbrooke, Sherbrooke, QC, Canada
| | - Jean-Philippe Thiran
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| | - Jonathan Rafael-Patiño
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
8
|
Ben-Atya H, Freiman M. P 2T 2: A physically-primed deep-neural-network approach for robust T 2 distribution estimation from quantitative T 2-weighted MRI. Comput Med Imaging Graph 2023; 107:102240. [PMID: 37224742 DOI: 10.1016/j.compmedimag.2023.102240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 04/27/2023] [Accepted: 04/27/2023] [Indexed: 05/26/2023]
Abstract
Estimating T2 relaxation time distributions from multi-echo T2-weighted MRI (T2W) data can provide valuable biomarkers for assessing inflammation, demyelination, edema, and cartilage composition in various pathologies, including neurodegenerative disorders, osteoarthritis, and tumors. Deep neural network (DNN) based methods have been proposed to address the complex inverse problem of estimating T2 distributions from MRI data, but they are not yet robust enough for clinical data with low Signal-to-Noise ratio (SNR) and are highly sensitive to distribution shifts such as variations in echo-times (TE) used during acquisition. Consequently, their application is hindered in clinical practice and large-scale multi-institutional trials with heterogeneous acquisition protocols. We propose a physically-primed DNN approach, called P2T2, that incorporates the signal decay forward model in addition to the MRI signal into the DNN architecture to improve the accuracy and robustness of T2 distribution estimation. We evaluated our P2T2 model in comparison to both DNN-based methods and classical methods for T2 distribution estimation using 1D and 2D numerical simulations along with clinical data. Our model improved the baseline model's accuracy for low SNR levels (SNR<80) which are common in the clinical setting. Further, our model achieved a ∼35% improvement in robustness against distribution shifts in the acquisition process compared to previously proposed DNN models. Finally, Our P2T2 model produces the most detailed Myelin-Water fraction maps compared to baseline approaches when applied to real human MRI data. Our P2T2 model offers a reliable and precise means of estimating T2 distributions from MRI data and shows promise for use in large-scale multi-institutional trials with heterogeneous acquisition protocols. Our source code is available at: https://github.com/Hben-atya/P2T2-Robust-T2-estimation.git.
Collapse
Affiliation(s)
- Hadas Ben-Atya
- Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
| | - Moti Freiman
- Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
9
|
Pizzolato M, Canales-Rodríguez EJ, Andersson M, Dyrby TB. Axial and radial axonal diffusivities and radii from single encoding strongly diffusion-weighted MRI. Med Image Anal 2023; 86:102767. [PMID: 36867913 DOI: 10.1016/j.media.2023.102767] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 12/13/2022] [Accepted: 02/08/2023] [Indexed: 02/18/2023]
Abstract
We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the sum of the contributions from only axons. At the same time, spherical averaging leads to a major simplification of the modeling by removing the need to explicitly account for the unknown distribution of axonal orientations. However, the spherically averaged signal acquired at strong diffusion weightings is not sensitive to the axial diffusivity, which cannot therefore be estimated although needed for modeling axons - especially in the context of multi-compartmental modeling. We introduce a new general method for the estimation of both the axial and radial axonal diffusivities at strong diffusion weightings based on kernel zonal modeling. The method could lead to estimates that are free from partial volume bias with gray matter or other isotropic compartments. The method is tested on publicly available data from the MGH Adult Diffusion Human Connectome project. We report reference values of axonal diffusivities based on 34 subjects, and derive estimates of axonal radii from only two shells. The estimation problem is also addressed from the angle of the required data preprocessing, the presence of biases related to modeling assumptions, current limitations, and future possibilities.
Collapse
Affiliation(s)
- Marco Pizzolato
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kgs. Lyngby, Denmark; Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark.
| | | | - Mariam Andersson
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
| | - Tim B Dyrby
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kgs. Lyngby, Denmark; Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
| |
Collapse
|
10
|
Liu H, Grouza V, Tuznik M, Siminovitch KA, Bagheri H, Peterson A, Rudko DA. Self-labelled encoder-decoder (SLED) for multi-echo gradient echo-based myelin water imaging. Neuroimage 2022; 264:119717. [PMID: 36367497 DOI: 10.1016/j.neuroimage.2022.119717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 10/07/2022] [Accepted: 10/27/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Reconstruction of high quality myelin water imaging (MWI) maps is challenging, particularly for data acquired using multi-echo gradient echo (mGRE) sequences. A non-linear least squares fitting (NLLS) approach has often been applied for MWI. However, this approach may produce maps with limited detail and, in some cases, sub-optimal signal to noise ratio (SNR), due to the nature of the voxel-wise fitting. In this study, we developed a novel, unsupervised learning method called self-labelled encoder-decoder (SLED) to improve gradient echo-based MWI data fitting. METHODS Ultra-high resolution, MWI data was collected from five mouse brains with variable levels of myelination, using a mGRE sequence. Imaging data was acquired using a 7T preclinical MRI system. A self-labelled, encoder-decoder network was implemented in TensorFlow for calculation of myelin water fraction (MWF) based on the mGRE signal decay. A simulated MWI phantom was also created to evaluate the performance of MWF estimation. RESULTS Compared to NLLS, SLED demonstrated improved MWF estimation, in terms of both stability and accuracy in phantom tests. In addition, SLED produced less noisy MWF maps from high resolution MR microscopy images of mouse brain tissue. It specifically resulted in lower noise amplification for all mouse genotypes that were imaged and yielded mean MWF values in white matter ROIs that were highly correlated with those derived from standard NLLS fitting. Lastly, SLED also exhibited higher tolerance to low SNR data. CONCLUSION Due to its unsupervised and self-labeling nature, SLED offers a unique alternative to analyze gradient echo-based MWI data, providing accurate and stable MWF estimations.
Collapse
Affiliation(s)
- Hanwen Liu
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Vladimir Grouza
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Marius Tuznik
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Katherine A Siminovitch
- Departments of Medicine and Immunology, University of Toronto, Toronto, ON, Canada; Lunenfeld Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada
| | - Hooman Bagheri
- Department of Human Genetics, McGill University, Montreal, QC, Canada
| | - Alan Peterson
- Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada; Department of Human Genetics, McGill University, Montreal, QC, Canada; Gerald Bronfman Department of Oncology, McGill University, Montreal, QC, Canada
| | - David A Rudko
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada; Department of Biomedical Engineering, McGill University, Montreal, QC, Canada.
| |
Collapse
|
11
|
Fischi-Gomez E, Girard G, Koch PJ, Yu T, Pizzolato M, Brügger J, Piredda GF, Hilbert T, Cadic-Melchior AG, Beanato E, Park CH, Morishita T, Wessel MJ, Schiavi S, Daducci A, Kober T, Canales-Rodríguez EJ, Hummel FC, Thiran JP. Variability and reproducibility of multi-echo T2 relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions. FRONTIERS IN RADIOLOGY 2022; 2:930666. [PMID: 37492668 PMCID: PMC10365099 DOI: 10.3389/fradi.2022.930666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 06/30/2022] [Indexed: 07/27/2023]
Abstract
Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T2 relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T2 relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model's parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space (T2IE) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T2 relaxometry dataset. To this end, we evaluated three different techniques for estimating the T2 spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that T2IE is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92.
Collapse
Affiliation(s)
- Elda Fischi-Gomez
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Translational Machine Learning Lab, Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| | - Gabriel Girard
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| | - Philipp J. Koch
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
- Department of Neurology, University of Lübeck, Lübeck, Germany
- Center of Brain, Behavior and Metabolism (CBBM), University of Lübeck, Lübeck, Germany
| | - Thomas Yu
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
| | - Marco Pizzolato
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Julia Brügger
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
| | - Gian Franco Piredda
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
| | - Tom Hilbert
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
| | - Andéol G. Cadic-Melchior
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
| | - Elena Beanato
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
| | - Chang-Hyun Park
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
| | - Takuya Morishita
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
| | - Maximilian J. Wessel
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
- Department of Neurology, University Hospital and Julius-Maximilians-University, Wuerzburg, Germany
| | - Simona Schiavi
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health (DINOGMI), University of Genoa, Genoa, Italy
- Diffusion Imaging and Connectivity Estimation (DICE) Lab, Department of Computer Science, University of Verona, Verona, Italy
| | - Alessandro Daducci
- Diffusion Imaging and Connectivity Estimation (DICE) Lab, Department of Computer Science, University of Verona, Verona, Italy
| | - Tobias Kober
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
| | - Erick J. Canales-Rodríguez
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Friedhelm C. Hummel
- Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland
- Clinical Neuroscience, University Hospital of Geneva (HUG), Geneva, Switzerland
| | - Jean-Philippe Thiran
- Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
12
|
Piredda GF, Hilbert T, Ravano V, Canales-Rodríguez EJ, Pizzolato M, Meuli R, Thiran JP, Richiardi J, Kober T. Data-driven myelin water imaging based on T 1 and T 2 relaxometry. NMR IN BIOMEDICINE 2022; 35:e4668. [PMID: 34936147 DOI: 10.1002/nbm.4668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 11/16/2021] [Accepted: 11/30/2021] [Indexed: 06/14/2023]
Abstract
Long acquisition times preclude the application of multiecho spin echo (MESE) sequences for myelin water fraction (MWF) mapping in daily clinical practice. In search of alternative methods, previous studies of interest explored the biophysical modeling of MWF from measurements of different tissue properties that can be obtained in scan times shorter than those required for the MESE. In this work, a novel data-driven estimation of MWF maps from fast relaxometry measurements is proposed and investigated. T1 and T2 relaxometry maps were acquired in a cohort of 20 healthy subjects along with a conventional MESE sequence. Whole-brain quantitative mapping was achieved with a fast protocol in 6 min 24 s. Reference MWF maps were derived from the MESE sequence (TA = 11 min 17 s) and their data-driven estimation from relaxometry measurements was investigated using three different modeling strategies: two general linear models (GLMs) with linear and quadratic regressors, respectively; a random forest regression model; and two deep neural network architectures, a U-Net and a conditional generative adversarial network (cGAN). Models were validated using a 10-fold crossvalidation. The resulting maps were visually and quantitatively compared by computing the root mean squared error (RMSE) between the estimated and reference MWF maps, the intraclass correlation coefficients (ICCs) between corresponding MWF values in different brain regions, and by performing Bland-Altman analysis. Qualitatively, the estimated maps appear to generally provide a similar, yet more blurred MWF contrast in comparison with the reference, with the cGAN model best capturing MWF variabilities in small structures. By estimating the average adjusted coefficient of determination of the GLM with quadratic regressors, we showed that 87% of the variability in the MWF values can be explained by relaxation times alone. Further quantitative analysis showed an average RMSE smaller than 0.1% for all methods. The ICC was greater than 0.81 for all methods, and the bias smaller than 2.19%. It was concluded that this work confirms the notion that relaxometry parameters contain a large part of the information on myelin water and that MWF maps can be generated from T1 /T2 data with minimal error. Among the investigated modeling approaches, the cGAN provided maps with the best trade-off between accuracy and blurriness. Fast relaxometry, like the 6 min 24 s whole-brain protocol used in this work in conjunction with machine learning, may thus have the potential to replace time-consuming MESE acquisitions.
Collapse
Affiliation(s)
- Gian Franco Piredda
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Tom Hilbert
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Veronica Ravano
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | | | - Marco Pizzolato
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Reto Meuli
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Jean-Philippe Thiran
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Jonas Richiardi
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Tobias Kober
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| |
Collapse
|
13
|
Fast, Accurate, and Robust T2 Mapping of Articular Cartilage by Neural Networks. Diagnostics (Basel) 2022; 12:diagnostics12030688. [PMID: 35328240 PMCID: PMC8947694 DOI: 10.3390/diagnostics12030688] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 02/25/2022] [Accepted: 03/09/2022] [Indexed: 12/31/2022] Open
Abstract
For T2 mapping, the underlying mono-exponential signal decay is traditionally quantified by non-linear Least-Squares Estimation (LSE) curve fitting, which is prone to outliers and computationally expensive. This study aimed to validate a fully connected neural network (NN) to estimate T2 relaxation times and to assess its performance versus LSE fitting methods. To this end, the NN was trained and tested in silico on a synthetic dataset of 75 million signal decays. Its quantification error was comparatively evaluated against three LSE methods, i.e., traditional methods without any modification, with an offset, and one with noise correction. Following in-situ acquisition of T2 maps in seven human cadaveric knee joint specimens at high and low signal-to-noise ratios, the NN and LSE methods were used to estimate the T2 relaxation times of the manually segmented patellofemoral cartilage. In-silico modeling at low signal-to-noise ratio indicated significantly lower quantification error for the NN (by medians of 6−33%) than for the LSE methods (p < 0.001). These results were confirmed by the in-situ measurements (medians of 10−35%). T2 quantification by the NN took only 4 s, which was faster than the LSE methods (28−43 s). In conclusion, NNs provide fast, accurate, and robust quantification of T2 relaxation times.
Collapse
|
14
|
Canales-Rodríguez EJ, Pizzolato M, Yu T, Piredda GF, Hilbert T, Radua J, Kober T, Thiran JP. Revisiting the T 2 spectrum imaging inverse problem: Bayesian regularized non-negative least squares. Neuroimage 2021; 244:118582. [PMID: 34536538 DOI: 10.1016/j.neuroimage.2021.118582] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/12/2021] [Accepted: 09/14/2021] [Indexed: 01/24/2023] Open
Abstract
Multi-echo T2 magnetic resonance images contain information about the distribution of T2 relaxation times of compartmentalized water, from which we can estimate relevant brain tissue properties such as the myelin water fraction (MWF). Regularized non-negative least squares (NNLS) is the tool of choice for estimating non-parametric T2 spectra. However, the estimation is ill-conditioned, sensitive to noise, and highly affected by the employed regularization weight. The purpose of this study is threefold: first, we want to underline that the apparently innocuous use of two alternative parameterizations for solving the inverse problem, which we called the standard and alternative regularization forms, leads to different solutions; second, to assess the performance of both parameterizations; and third, to propose a new Bayesian regularized NNLS method (BayesReg). The performance of BayesReg was compared with that of two conventional approaches (L-curve and Chi-square (X2) fitting) using both regularization forms. We generated a large dataset of synthetic data, acquired in vivo human brain data in healthy participants for conducting a scan-rescan analysis, and correlated the myelin content derived from histology with the MWF estimated from ex vivo data. Results from synthetic data indicate that BayesReg provides accurate MWF estimates, comparable to those from L-curve and X2, and with better overall stability across a wider signal-to-noise range. Notably, we obtained superior results by using the alternative regularization form. The correlations reported in this study are higher than those reported in previous studies employing the same ex vivo and histological data. In human brain data, the estimated maps from L-curve and BayesReg were more reproducible. However, the T2 spectra produced by BayesReg were less affected by over-smoothing than those from L-curve. These findings suggest that BayesReg is a good alternative for estimating T2 distributions and MWF maps.
Collapse
Affiliation(s)
- Erick Jorge Canales-Rodríguez
- Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland.
| | - Marco Pizzolato
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark; Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland
| | - Thomas Yu
- Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland; Medical Image Analysis Laboratory, Center for Biomedical Imaging (CIBM), University of Lausanne, Switzerland
| | - Gian Franco Piredda
- Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland; Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Tom Hilbert
- Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland; Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Joaquim Radua
- Imaging of Mood- and Anxiety-Related Disorders (IMARD) group, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), CIBERSAM, Barcelona, Spain; Department of Psychosis Studies, Institute of Psychiatry, Psychology, and Neuroscience, King's College London, London, United Kingdom; Department of Clinical Neuroscience, Centre for Psychiatric Research and Education, Karolinska Institutet, Stockholm, Sweden
| | - Tobias Kober
- Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland; Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Jean-Philippe Thiran
- Signal Processing Laboratory (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-IEL-LTS5, Station 11, CH-1015, Lausanne, Switzerland; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
15
|
Avram AV, Sarlls JE, Basser PJ. Whole-Brain Imaging of Subvoxel T1-Diffusion Correlation Spectra in Human Subjects. Front Neurosci 2021; 15:671465. [PMID: 34177451 PMCID: PMC8232058 DOI: 10.3389/fnins.2021.671465] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 05/14/2021] [Indexed: 12/12/2022] Open
Abstract
T1 relaxation and water mobility generate eloquent MRI tissue contrasts with great diagnostic value in many neuroradiological applications. However, conventional methods do not adequately quantify the microscopic heterogeneity of these important biophysical properties within a voxel, and therefore have limited biological specificity. We describe a new correlation spectroscopic (CS) MRI method for measuring how T1 and mean diffusivity (MD) co-vary in microscopic tissue environments. We develop a clinical pulse sequence that combines inversion recovery (IR) with single-shot isotropic diffusion encoding (IDE) to efficiently acquire whole-brain MRIs with a wide range of joint T1-MD weightings. Unlike conventional diffusion encoding, the IDE preparation ensures that all subvoxel water pools are weighted by their MDs regardless of the sizes, shapes, and orientations of their corresponding microscopic diffusion tensors. Accordingly, IR-IDE measurements are well-suited for model-free, quantitative spectroscopic analysis of microscopic water pools. Using numerical simulations, phantom experiments, and data from healthy volunteers we demonstrate how IR-IDE MRIs can be processed to reconstruct maps of two-dimensional joint probability density functions, i.e., correlation spectra, of subvoxel T1-MD values. In vivo T1-MD spectra show distinct cerebrospinal fluid and parenchymal tissue components specific to white matter, cortical gray matter, basal ganglia, and myelinated fiber pathways, suggesting the potential for improved biological specificity. The one-dimensional marginal distributions derived from the T1-MD correlation spectra agree well with results from other relaxation spectroscopic and quantitative MRI studies, validating the T1-MD contrast encoding and the spectral reconstruction. Mapping subvoxel T1-diffusion correlations in patient populations may provide a more nuanced, comprehensive, sensitive, and specific neuroradiological assessment of the non-specific changes seen on fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted MRIs (DWIs) in cancer, ischemic stroke, or brain injury.
Collapse
Affiliation(s)
- Alexandru V Avram
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD, United States.,Center for Neuroscience and Regenerative Medicine, The Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, MD, United States
| | - Joelle E Sarlls
- National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| | - Peter J Basser
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD, United States
| |
Collapse
|
16
|
Age- and gender-related differences in brain tissue microstructure revealed by multi-component T 2 relaxometry. Neurobiol Aging 2021; 106:68-79. [PMID: 34252873 DOI: 10.1016/j.neurobiolaging.2021.06.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 05/30/2021] [Accepted: 06/01/2021] [Indexed: 12/19/2022]
Abstract
In spite of extensive work, inconsistent findings and lack of specificity in most neuroimaging techniques used to examine age- and gender-related patterns in brain tissue microstructure indicate the need for additional research. Here, we performed the largest Multi-component T2 relaxometry cross-sectional study to date in healthy adults (N = 145, 18-60 years). Five quantitative microstructure parameters derived from various segments of the estimated T2 spectra were evaluated, allowing a more specific interpretation of results in terms of tissue microstructure. We found similar age-related myelin water fraction (MWF) patterns in men and women but we also observed differential male related results including increased MWF content in a few white matter tracts, a faster decline with age of the intra- and extra-cellular water fraction and its T2 relaxation time (i.e. steeper age related negative slopes) and a faster increase in the free and quasi-free water fraction, spanning the whole grey matter. Such results point to a sexual dimorphism in brain tissue microstructure and suggest a lesser vulnerability to age-related changes in women.
Collapse
|