1
|
Nascimento MM, Nascimento ML, Pereira Dos Anjos J, Cunha RL, da Rocha GO, Ferreira Dos Santos I, Pereira PADP, de Andrade JB. A green method for the determination of illicit drugs in wastewater and surface waters-based on a semi-automated liquid-liquid microextraction device. J Chromatogr A 2023; 1710:464230. [PMID: 37826922 DOI: 10.1016/j.chroma.2023.464230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 07/14/2023] [Accepted: 07/19/2023] [Indexed: 10/14/2023]
Abstract
Liquid-phase microextraction (LPME) is a simple, low-cost, and eco-friendly technique that enables the detection of trace concentrations of organic contaminants in water samples. In this work, a novel customized microextraction device was developed for the LPME extraction and preconcentration of nine illicit drugs in surface water and influent and effluent wastewater samples, followed by analysis by GC-MS without derivatization. The customized device was semi-automated by coupling it with a peristaltic pump to perform the collection of the upper layer of the organic phase. The extraction parameters affecting the LPME efficiency were optimized. The optimized conditions were: 100 µL of a toluene/DCM/EtAc mixture as extractor solvent; 30min of extraction time under vortex agitation (500rpm) and a solution pH of 11.6. The limits of detection and quantification ranged from 10.5ng L-1 (ethylone) to 22.0ng L-1 (methylone), and from 34.9ng L-1 to 73.3ng L-1 for these same compounds, respectively. The enrichment factors ranged from 39.7 (MDMA) to 117 (cocaethylene) and the relative recoveries ranged from 80.4% (N-ethylpentylone) to 120% (cocaine and cocaine-d3). The method was applied to real surface water, effluent, and influent wastewater samples collected in Salvador City, Bahia, Brazil. Cocaine was the main drug detected and quantified in wastewater samples, and its concentration ranged from 312ng L-1 to 1,847ng L-1. Finally, the AGREE metrics were applied to verify the greenness of the proposed method, and an overall score of 0.56 was achieved, which was considered environmentally friendly.
Collapse
Affiliation(s)
- Madson Moreira Nascimento
- Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil
| | - Melise Lemos Nascimento
- Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil
| | - Jeancarlo Pereira Dos Anjos
- Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Centro Universitário SENAI CIMATEC, Av. Orlando Gomes, 1845 - Piatã, Salvador, BA 41650-010, Brazil
| | - Ricardo Leal Cunha
- Laboratório de Toxicologia Forense, Instituto de Análises e Pesquisas Forenses - IAPF, Polícia Científica, São Cristóvão, SE 49100-000, Brazil; Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas, Campinas, SP 13083-859, Brazil
| | - Gisele Olimpio da Rocha
- Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto de Química, Universidade Federal da Bahia, Campus de Ondina, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil
| | - Ivanice Ferreira Dos Santos
- Universidade Estadual de Feira de Santana, Av. Transnordestina, s/n - Feira de Santana, Novo Horizonte - BA 44036-900, BA, Brazil
| | - Pedro Afonso de Paula Pereira
- Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto de Química, Universidade Federal da Bahia, Campus de Ondina, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Centro Universitário SENAI CIMATEC, Av. Orlando Gomes, 1845 - Piatã, Salvador, BA 41650-010, Brazil
| | - Jailson Bittencourt de Andrade
- Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Centro Universitário SENAI CIMATEC, Av. Orlando Gomes, 1845 - Piatã, Salvador, BA 41650-010, Brazil.
| |
Collapse
|
2
|
Santos LMM, Nascimento MM, Borges SDS, Bomfim E, Macedo VDJ, Silva LA. Green photocatalytic remediation of Fenthion using composites with natural red clay and non-toxic metal oxides with visible light irradiation. ENVIRONMENTAL TECHNOLOGY 2023; 44:118-129. [PMID: 34344269 DOI: 10.1080/09593330.2021.1964611] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 07/29/2021] [Indexed: 06/13/2023]
Abstract
In the present work, composites with non-toxic metal oxides, such as TiO2 and ZnO, and a natural red clay (taua) reach in hematite were used in the photocatalytic degradation of Fenthion. The composite TiO2/Taua (0.5:1 wt. ratio) and pure TiO2 were prepared by sol-gel method while ZnO/Taua (0.5:1 wt. ratio) and pure ZnO were prepared by Pechini method. The materials were characterized by XRD, SEM, EDX, and DRS. The anatase phase was formed in both pure TiO2 and TiO2/Taua, while the hexagonal phase was formed in pure ZnO and ZnO/Taua. The bandgap energies for the two composites were narrowed compared to the respective pure oxides as consequence of the hematite (α-Fe2O3, Eg = 2.1 eV) in the red clay, reaching 2.1 eV for TiO2/Taua and 2.0 eV for ZnO/Taua, while the bandgap energies for pure TiO2 and ZnO were 3.2 and 3.0 eV, respectively. Fenthion was not degraded in the dark, but the concentration droped 20% after 180 min under visible light irradiation without photocatalyst and 60% after 210 min in the presence of the pure red clay. Both TiO2/Taua and ZnO/Taua composites were also photocatalytic active to degrade Fenthion (λ > 420 nm), with degradation of 78% (in 180 min) and 85% (in 210 min) respectively. In the optimized conditions (pH 2, 100 mg L-1 of H2O2 and 30 mg L-1 of Fenthion), the ZnO/Taua composite was the most efficient, reaching 89% degradation in up to 30 min, with Fenthion sulfoxide as the degradation product.
Collapse
Affiliation(s)
| | - Madson M Nascimento
- Instituto de Química, Universidade Federal da Bahia, Salvador, Bahia, Brazil
- Instituto Nacional de Ciência e Tecnologia, INCT, de Energia e Ambiente, Universidade Federal da Bahia, Salvador, Bahia, Brazil
| | | | - Elton Bomfim
- Instituto de Química, Universidade Federal da Bahia, Salvador, Bahia, Brazil
| | | | - Luciana Almeida Silva
- Instituto de Química, Universidade Federal da Bahia, Salvador, Bahia, Brazil
- Instituto Nacional de Ciência e Tecnologia, INCT, de Energia e Ambiente, Universidade Federal da Bahia, Salvador, Bahia, Brazil
| |
Collapse
|
3
|
Behpour M, Maghsoudi M, Nojavan S. Analysis of methamphetamine, methadone, tramadol, and buprenorphine in biological samples by ion mobility spectrometry after electromembrane extraction in tandem with slug flow microextraction. J Chromatogr A 2022; 1678:463355. [PMID: 35908513 DOI: 10.1016/j.chroma.2022.463355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/16/2022] [Accepted: 07/18/2022] [Indexed: 10/17/2022]
Abstract
A novel tandem extraction method based on electromembrane extraction (EME) and slug flow microextraction (SFME) was developed for the extraction of some narcotics (methamphetamine, methadone, tramadol, and buprenorphine) from biological samples. The analytes were quantified by corona discharge-ion mobility spectrometry (CD-IMS). In this method, initially, analytes were extracted using an EME procedure (step-1). After that, the acceptor solution of the first step containing target analytes was applied in an SFME procedure (step-2) as a donor solution for further preconcentration. In the second step, analytes were extracted from an aqueous solution into an organic extractant. The optimum EME and SFME conditions were as follows: type of supported liquid membrane: 2-nitrophenyl octyl ether containing 10% v/v di-(2-ethylhexyl) phosphate, acceptor solution pH: 1.0, sample solution pH: 4.0, voltage: 248 V, extraction time: 17.5 min, tilting number of glass capillary tube: 10 times, type of the organic extractant: toluene, the concentration of NaOH solution: 400 mM. Under optimum extraction conditions, good linearity was obtained in the range of 0.50-750.0 ng/mL with coefficients of determination (r2) ≥ 0.991. The limits of detection and quantification were achieved in the range of 0.15-3.5 ng/mL and 0.50-12.0 ng/mL, respectively. The inter-day and intra-day precisions (n = 3) provided RSDs lower than 12.8% and 12.7%, respectively. Enrichment factors and extraction recoveries of the analytes were in the range of 255.7 to 505.4 and 37.6-78.3%, respectively. Comparing the EME/HPLC-UV with EME-SFME/CD-IMS showed that using the tandem extraction method improved the enrichment factors by more than 2.7 times and limits of detection and quantification by more than 15 times. Finally, this procedure was used to quantify target analytes in plasma and urine samples.
Collapse
Affiliation(s)
- Majid Behpour
- Department of analytical chemistry and pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran
| | - Majid Maghsoudi
- Department of analytical chemistry and pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran
| | - Saeed Nojavan
- Department of analytical chemistry and pollutants, Shahid Beheshti University, G. C., Evin, Tehran 1983969411, Iran.
| |
Collapse
|
4
|
Silva TLR, de Queiroz MELR, de Oliveira AF, Rodrigues AAZ, Neves AA, Vieira PAF, de Queiroz JH, Barbosa VODP. Microextraction technique associated with gas chromatography-mass spectrometry for determining pesticide residues in urine. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART. B, PESTICIDES, FOOD CONTAMINANTS, AND AGRICULTURAL WASTES 2022; 57:165-175. [PMID: 35175180 DOI: 10.1080/03601234.2022.2038505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Urine is one of the biological matrices most used for detecting human contamination, as it is representative and easily obtained via noninvasive sampling. This study proposes a fast, accurate, and ecological method based on liquid-liquid microextraction with low-temperature partition (μLLE/LTP). It was validated to determine nine pesticides (lindane, alachlor, aldrin, chlorpyrifos, dieldrin, endrin, DDT, bifenthrin, and permethrin) in human urine, in association with gas chromatography coupled with mass spectrometry (GC-MS). The technique was optimized through a factorial design. The best conditions for the simultaneous extraction of the analytes comprised the addition of 600 µL of water and 600 µL of acetonitrile (extracting solvent) to a 500-µL urine sample, followed by vortexing for 60 s. By freezing the samples for 4 h, it was possible to extract the pesticides and perform the extract clean-up simultaneously. The parameters selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy were used to appraise the performance of the method. Good values of selectivity and linearity (R2 > 0.990), LOQ (0.39-1.02 μg L-1), accuracy (88-119% recovery), and precision (%CV ≤ 15%) were obtained. The μLLE/LTP-GC-MS method was applied to authentic urine samples collected from volunteers in Southeast Brazil.
Collapse
Affiliation(s)
- Thaís L R Silva
- Department of Chemistry, Universidade Federal de Viçosa, Viçosa, Minas Gerais, Brazil
| | | | | | - Alessandra A Z Rodrigues
- Department of Chemistry, Universidade Federal de Viçosa, Viçosa, Minas Gerais, Brazil
- Department of Agricultural Engineering, Universidade Federal de Viçosa, Viçosa, Minas Gerais, Brazil
| | - Antônio Augusto Neves
- Department of Chemistry, Universidade Federal de Viçosa, Viçosa, Minas Gerais, Brazil
| | - Patrícia A F Vieira
- Department of Nutrition and Health, Universidade Federal de Viçosa, Viçosa, Minas Gerais, Brazil
| | - José Humberto de Queiroz
- Department of Biochemistry and Molecular Biology, Universidade Federal de Viçosa, Viçosa, Minas Gerais, Brazil
| | | |
Collapse
|
5
|
Ping T, Zheng M, Zhang P, Yan T, Miao X, Wang K, Lian K. Determination of 12 anti-obesity drugs in human plasma by a 96-well protein precipitation plate using HPLC-MS. RSC Adv 2022; 12:26016-26022. [PMID: 36199600 PMCID: PMC9469181 DOI: 10.1039/d2ra03423a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 09/06/2022] [Indexed: 11/21/2022] Open
Abstract
A 96-well protein precipitation plate combined with HPLC-MS/MS was developed for the determination of 12 anti-obesity drugs in human plasma; the detection method showed high throughout and high sensitivity with suitable recovery.
Collapse
Affiliation(s)
- Tengteng Ping
- School of Public Health, Hebei Medical University, Shijiazhuang, 050017, China
| | - Min Zheng
- Jinan Centre for Disease Control and Prevention, Jinan, 250000, China
| | - Pingping Zhang
- Department of Reproductive Genetic Family, Hebei General Hospital, Shijiazhuang, Hebei, 050000, China
| | - Tianhao Yan
- School of Public Health, Hebei Medical University, Shijiazhuang, 050017, China
| | - Xufeng Miao
- Physical Education Department, Hebei Medical University, Shijiazhuang, 050017, China
| | - Ke Wang
- Shijiazhuang Centre for Disease Control and Prevention, Shijiazhuang, 050011, China
| | - Kaoqi Lian
- School of Public Health, Hebei Medical University, Shijiazhuang, 050017, China
- Hebei Key Laboratory of Environment and Human Health, Shijiazhuang, 050017, China
| |
Collapse
|
6
|
Dispersive liquid-liquid microextraction of 11-nor-Δ9-tetrahydrocannabinol-carboxylic acid applied to urine testing. Bioanalysis 2021; 14:87-100. [PMID: 34860122 DOI: 10.4155/bio-2021-0237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Aim: THC-COOH is the major metabolite of Δ9-tetrahydrocannabinol commonly tested in urine to determine cannabis intake. In this study, a method based on dispersive liquid-liquid microextraction was developed for testing THC-COOH in urine. Materials & methods: Hydrolyzed urine specimens were extracted via dispersive liquid-liquid microextraction with acetonitrile (disperser solvent) and chloroform (extraction solvent). Derivatization was performed with N,O-Bis(trimethylsilyl)trifluoroacetamide with 1% trichloro(chloromethyl)silane. Analysis was performed by GC-MS/MS. Results: The method showed acceptable linearity (5-500 ng/ml), imprecision (<10.5%) and bias (<4.9%). Limits of detection and quantitation were 1 and 5 ng/ml, respectively. Twenty-four authentic samples were analyzed, with 22 samples being positive for THC-COOH. Conclusion: The proposed method is more environmentally friendly and provided good sensitivity, selectivity and reproducibility.
Collapse
|
7
|
Abbasi S, Haeri SA. Enrichment of psychotropic drugs using rhamnolipid bioaggregates after electromembrane extraction based on an agarose gel using a rotating electrode as a green and organic solvent-free strategy. J Chromatogr A 2021; 1655:462500. [PMID: 34487877 DOI: 10.1016/j.chroma.2021.462500] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 08/25/2021] [Accepted: 08/26/2021] [Indexed: 11/16/2022]
Abstract
We here present an efficient approach for the tandem extraction of psychotropic drugs using biodegradable materials. In this regard, gel electromembrane extraction (G-EME) was combined with the emulsification-based microextraction (ME) technique by rhamnolipid bioaggregates as a green extraction approach. The tandem extraction technique consists of two stages: (i) extraction of psychotropic drugs from human urine samples to the acceptor phase situated on the other side of the agarose gel membrane, and (ii) transfer of analytes from the acceptor phase into a colloidal phase of rhamnolipid biosurfactants. The colloidal phase was formed by adding rhamnolipid biosurfactants to the extracted phase of the first step. The colloidal phase was finally injected into a liquid chromatographic system for quantitative analysis. G-EME mechanism is based on electrokinetic migration of charged species toward oppositely charged electrode located in the acceptor solution under the influence of the electric field. After extraction, the analytes were trapped in an emulsion phase floating on the surface of the solution and at the end were injected into the liquid chromatographic system. The method provided good linearity in the ranges of 5-100 and 10-100 μg. L-1 for methamphetamine and amphetamine, respectively with (r2 > 0.992). Also, the detection limits (LODs) were 1 and 5 μg. L-1 for methamphetamine and amphetamine, respectively. The mean extraction recoveries by G-EME-ME for real samples at three spiked concentrations were in the range 95.9-101.1% and complete analytical workflow within only 18 min.
Collapse
Affiliation(s)
- Shahryar Abbasi
- Department of Chemistry, Faculty of Science, Ilam University, Ilam, Iran
| | - Seyed Ammar Haeri
- Department of Chemistry, Faculty of Science, Ilam University, Ilam, Iran.
| |
Collapse
|
8
|
Ahmad SM, Gonçalves OC, Oliveira MN, Neng NR, Nogueira JMF. Application of Microextraction-Based Techniques for Screening-Controlled Drugs in Forensic Context-A Review. Molecules 2021; 26:2168. [PMID: 33918766 PMCID: PMC8070059 DOI: 10.3390/molecules26082168] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/03/2021] [Accepted: 04/06/2021] [Indexed: 01/12/2023] Open
Abstract
The analysis of controlled drugs in forensic matrices, i.e., urine, blood, plasma, saliva, and hair, is one of the current hot topics in the clinical and toxicological context. The use of microextraction-based approaches has gained considerable notoriety, mainly due to the great simplicity, cost-benefit, and environmental sustainability. For this reason, the application of these innovative techniques has become more relevant than ever in programs for monitoring priority substances such as the main illicit drugs, e.g., opioids, stimulants, cannabinoids, hallucinogens, dissociative drugs, and related compounds. The present contribution aims to make a comprehensive review on the state-of-the art advantages and future trends on the application of microextraction-based techniques for screening-controlled drugs in the forensic context.
Collapse
Affiliation(s)
- Samir M. Ahmad
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Molecular Pathology and Forensic Biochemistry Laboratory, CiiEM, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
- Forensic and Psychological Sciences Laboratory Egas Moniz, Campus Universitário—Quinta da Granja, Monte da Caparica, 2829-511 Caparica, Portugal
| | - Oriana C. Gonçalves
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Mariana N. Oliveira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
| | - Nuno R. Neng
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| | - José M. F. Nogueira
- Centro de Química Estrutural, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal; (O.C.G.); (M.N.O.)
- Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
| |
Collapse
|
9
|
Bressan C, Ayala-Cabrera JF, Santos FJ, Cuadras S, Garrostas L, Monfort N, Alechaga É, Moyano E, Ventura R. Analysis of hydroxylated phenylalkylamine stimulants in urine by GC-APPI-HRMS. Anal Bioanal Chem 2020; 412:7837-7850. [PMID: 32954468 DOI: 10.1007/s00216-020-02913-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 08/04/2020] [Accepted: 08/24/2020] [Indexed: 11/27/2022]
Abstract
A gas chromatography-atmospheric pressure photoionization-high-resolution mass spectrometry (GC-APPI-HRMS) method was developed for the determination of eight phenylalkylamine stimulants in urine samples. Spiked urine samples were hydrolyzed, processed by solid-phase extraction, and derivatized before analysis. Two derivatization reactions were studied: the formation of trimethylsilyl (TMS) derivatives with N-methyl-N-trimethylsilyl trifluoroacetamide (MSTFA) and trimethylsilyl/trifluoroacetyl (TMS/TFA) derivatives with MSTFA and N-methyl-bis (trifluoroacetamide) (MBTFA) as derivatization reagents. Gas chromatography of both derivatives was performed with a 100% dimethylsiloxane column and a good separation of all isomeric compounds was achieved. To maximize the signal of the protonated molecule [M+H]+, the APPI most critical parameters were optimized. Three solvents were tested as dopant agents, with acetone yielding the lower in-source collision-induced dissociation (CID) fragmentation. The acquisition was performed in full scan and product ion scan (parallel reaction monitoring, PRM) using a quadrupole-Orbitrap mass analyzer (35,000 FWHM at m/z 200) in positive ion detection mode. At the optimal working conditions, the full scan method was evaluated for the fulfillment of identification requirements in doping analysis. Selectivity, limits of detection, matrix effect, and precision were estimated to validate the method for confirmation purposes and its applicability was tested by the analysis of spiked samples as well as by the analysis of samples obtained after the administration of some of the compounds to healthy volunteers. Results were compared with those obtained by GC-electron ionization-MS, demonstrating that the GC-APPI-HRMS method improved selectivity and sensibility, achieving lower limits of detection and satisfactory reproducibility.
Collapse
Affiliation(s)
- Claudia Bressan
- Catalonian Antidoping Laboratory, Doping Control Research Group, IMIM (Hospital del Mar Medical Research Institute), Doctor Aiguader 88, 08003, Barcelona, Spain
| | - Juan F Ayala-Cabrera
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Av. Diagonal 645, 08028, Barcelona, Spain
| | - Francisco Javier Santos
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Av. Diagonal 645, 08028, Barcelona, Spain
| | - Susana Cuadras
- Catalonian Antidoping Laboratory, Doping Control Research Group, IMIM (Hospital del Mar Medical Research Institute), Doctor Aiguader 88, 08003, Barcelona, Spain
| | - Lorena Garrostas
- Catalonian Antidoping Laboratory, Doping Control Research Group, IMIM (Hospital del Mar Medical Research Institute), Doctor Aiguader 88, 08003, Barcelona, Spain
| | - Núria Monfort
- Catalonian Antidoping Laboratory, Doping Control Research Group, IMIM (Hospital del Mar Medical Research Institute), Doctor Aiguader 88, 08003, Barcelona, Spain
| | - Élida Alechaga
- Catalonian Antidoping Laboratory, Doping Control Research Group, IMIM (Hospital del Mar Medical Research Institute), Doctor Aiguader 88, 08003, Barcelona, Spain
| | - Encarnación Moyano
- Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Av. Diagonal 645, 08028, Barcelona, Spain
| | - Rosa Ventura
- Catalonian Antidoping Laboratory, Doping Control Research Group, IMIM (Hospital del Mar Medical Research Institute), Doctor Aiguader 88, 08003, Barcelona, Spain.
| |
Collapse
|
10
|
Borden SA, Palaty J, Termopoli V, Famiglini G, Cappiello A, Gill CG, Palma P. MASS SPECTROMETRY ANALYSIS OF DRUGS OF ABUSE: CHALLENGES AND EMERGING STRATEGIES. MASS SPECTROMETRY REVIEWS 2020; 39:703-744. [PMID: 32048319 DOI: 10.1002/mas.21624] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
Mass spectrometry has been the "gold standard" for drugs of abuse (DoA) analysis for many decades because of the selectivity and sensitivity it affords. Recent progress in all aspects of mass spectrometry has seen significant developments in the field of DoA analysis. Mass spectrometry is particularly well suited to address the rapidly proliferating number of very high potency, novel psychoactive substances that are causing an alarming number of fatalities worldwide. This review surveys advancements in the areas of sample preparation, gas and liquid chromatography-mass spectrometry, as well as the rapidly emerging field of ambient ionization mass spectrometry. We have predominantly targeted literature progress over the past ten years and present our outlook for the future. © 2020 Periodicals, Inc. Mass Spec Rev.
Collapse
Affiliation(s)
- Scott A Borden
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
| | - Jan Palaty
- LifeLabs Medical Laboratories, Burnaby, BC, V3W 1H8, Canada
| | - Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Achille Cappiello
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
- Department of Chemistry, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, WA, 98195
| | - Pierangela Palma
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| |
Collapse
|
11
|
Shi JW, Zhou JF, He X, Zhang Y. Rapid Analysis of Four Amphetamines in Urine by Self-Made Pipette-Tip Solid-Phase Extraction Followed by GC-MS/MS. J Chromatogr Sci 2020; 58:569-575. [DOI: 10.1093/chromsci/bmaa018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 01/02/2020] [Indexed: 01/25/2023]
Abstract
Abstract
A simple and rapid pipette-tip solid-phase extraction (PT-SPE) procedure with derivatization prior to gas chromatography triple quadrupole mass spectrometry analysis is developed for the simultaneous determination of amphetamine (AMP), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA) in urine samples. The PT-SPE procedure using self-made sorbent could extract drugs within 6 min from 100-μL urine samples, requiring low solvent-consumption (<2.0 mL). Besides, the self-made pipette tip could be reused at least five times. Under optimized conditions, the recoveries of four amphetamines at spiked levels (low, medium and high) ranged from 87.7 to 110.4%, with relative standard deviations < 9.5%. The limit of detections and limit of quantifications for AMP, MA, MDA and MDMA were in the range of 2.52–8.25 ng⋅mL−1 and 8.4–27.5 ng⋅mL−1, respectively. Validation results show that the proposed method is suitable for the quantitation of amphetamines and has been successfully applied in the urine samples of suspected drug abusers.
Collapse
Affiliation(s)
- Jia-Wei Shi
- Zhejiang Pharmaceutical College, Ningbo, 315104, China
| | | | - Xiong He
- Zhejiang Pharmaceutical College, Ningbo, 315104, China
| | - Yun Zhang
- Department of Chemistry, Zhejiang University, Hangzhou 310027, China
| |
Collapse
|
12
|
Will C, Omena E, Corazza G, Bernardi G, Merib J, Carasek E. Expanding the applicability of magnetic ionic liquids for multiclass determination in biological matrices based on dispersive liquid–liquid microextraction and HPLC with diode array detector analysis. J Sep Sci 2020; 43:2657-2665. [DOI: 10.1002/jssc.202000143] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 04/03/2020] [Accepted: 04/03/2020] [Indexed: 01/26/2023]
Affiliation(s)
- Camila Will
- Departamento de QuímicaUniversidade Federal de Santa Catarina Florianópolis Brazil
| | - Eduarda Omena
- Departamento de QuímicaUniversidade Federal de Santa Catarina Florianópolis Brazil
| | - Gabriela Corazza
- Departamento de QuímicaUniversidade Federal de Santa Catarina Florianópolis Brazil
| | - Gabrieli Bernardi
- Departamento de QuímicaUniversidade Federal de Santa Catarina Florianópolis Brazil
| | - Josias Merib
- Departamento de FarmacociênciasUniversidade Federal de Ciências da Saúde de Porto Alegre Porto Alegre Brazil
| | - Eduardo Carasek
- Departamento de QuímicaUniversidade Federal de Santa Catarina Florianópolis Brazil
| |
Collapse
|
13
|
Borahan T, Tekin Z, Zaman BT, Chormey DS, Bakirdere S. An analytical strategy for propoxur determination in raisin samples with matrix matching method after dispersive liquid-liquid microextraction. J Food Compost Anal 2019. [DOI: 10.1016/j.jfca.2019.103315] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
14
|
Recent advances in microextraction procedures for determination of amphetamines in biological samples. Bioanalysis 2019; 11:437-460. [DOI: 10.4155/bio-2018-0207] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Amphetamine and its related derivatives have stimulant and hallucinogenic properties. Illegal use of these drugs is an increasing global problem resulting in significant public health and legal problems. Deaths have been reported after intake of these drugs due to overdose. It is important to determine the type and concentration of illicit drugs in biological samples. These compounds are found in complex matrices at low concentration levels. The microextraction techniques are dominant sample preparation procedure and they are widely accepted as the most labor-intensive part of the bioanalytical process. For this purpose, a survey of recent published advances in microextraction procedures for quantification of amphetamines in biological samples found in the different databases from 2008 to date will be conducted.
Collapse
|
15
|
He Y, Concheiro-Guisan M. Microextraction sample preparation techniques in forensic analytical toxicology. Biomed Chromatogr 2018; 33:e4444. [DOI: 10.1002/bmc.4444] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2018] [Accepted: 11/15/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Yi He
- Department of Sciences, John Jay College of Criminal Justice; The City University of New York; New York NY USA
| | - Marta Concheiro-Guisan
- Department of Sciences, John Jay College of Criminal Justice; The City University of New York; New York NY USA
| |
Collapse
|
16
|
Bravo MA, Parra S, Vargas C, Quiroz W. Determination of organotin compounds in sediment samples by dispersive liquid-liquid microextraction followed by gas chromatography – Pulsed flame photometric detection (DLLME-GC-PFPD). Microchem J 2017. [DOI: 10.1016/j.microc.2017.05.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
17
|
Mansour FR, Khairy MA. Pharmaceutical and biomedical applications of dispersive liquid–liquid microextraction. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1061-1062:382-391. [DOI: 10.1016/j.jchromb.2017.07.055] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2017] [Revised: 07/09/2017] [Accepted: 07/29/2017] [Indexed: 01/18/2023]
|
18
|
Affiliation(s)
- Jarinya SITTIWONG
- Department of Chemistry, Faculty of Science, Chulalongkorn University
| | - Fuangfa UNOB
- Department of Chemistry, Faculty of Science, Chulalongkorn University
| |
Collapse
|