1
|
Rezaei N, Seidi S, Fotouhi M. On-chip electromembrane extraction using deep eutectic solvent and red-green-blue analysis by quick-response code readable customized application on a smartphone for measuring salicylic acid in pharmaceutical and plasma samples. J Chromatogr A 2023; 1708:464347. [PMID: 37696125 DOI: 10.1016/j.chroma.2023.464347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 08/19/2023] [Accepted: 08/30/2023] [Indexed: 09/13/2023]
Abstract
The current work presents an on-chip electromembrane extraction (OC-EME) method using deep eutectic solvent followed by QR code-based red-green-blue (RGB) analysis for measuring salicylic acid (SA) in plasma and pharmaceutical samples. The RGB analysis was performed based on forming the SA-Fe3+ complex in the acceptor phase giving a purple solution. The QR code readable customized app provided rapid, easy, and cost-less qualification and quantification of SA with the aid of principal component analysis (PCA). Parameters affecting OC-EME, including the supported liquid membrane (SLM), pH of the donor and acceptor phases, applied voltage, and sample flow rate, were optimized. Also, the concentration of FeCl3, as a chromogenic reagent, and its reaction time with SA were investigated to find the best concentration-dependent signal. Under the optimized conditions, a good relationship was observed between the green intensity and SA concentration within the range of 1.0-100.0 mg l-1 (R2 = 0.9946) in water and 5.0-100.0 mg l-1 (R2 = 0.9902) in plasma. Intra- and inter-day RSDs% were obtained less than 4.7% and 7.7%, respectively. Finally, the method was successfully applied for measuring SA in foot corn treatment, Aspirin medicines, and human plasma, with relative recoveries between 89.0 and 129.2%.
Collapse
Affiliation(s)
- Neda Rezaei
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran 15418-49611, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran 15418-49611, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran 15418-49611, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran 15418-49611, Iran.
| | - Mina Fotouhi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran 15418-49611, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran 15418-49611, Iran
| |
Collapse
|
2
|
Zaroudi F, Nasihatkon B, Hosseinzadeh R, Fakhari AR, Seidi S. Miniaturized on-chip electromembrane extraction with QR code-based red-green-blue analysis using a customized Android application for copper determination in environmental and food samples. Food Chem 2023; 414:135667. [PMID: 36808032 DOI: 10.1016/j.foodchem.2023.135667] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 02/03/2023] [Accepted: 02/08/2023] [Indexed: 02/15/2023]
Abstract
A miniaturized on-chip electromembrane extraction device with QR code-based red-green-blue analysis was designed to determine copper in water, food, and soil. The acceptor droplet consisted of ascorbic acid as the reducing agent and bathocuproine as the chromogenic reagent. The formation of a yellowish-orange complex was a sign of copper in the sample. Then, the qualitative and quantitative analysis of the dried acceptor droplet was done by the customized Android app that was developed based on image analysis concepts. In this application, principal component analysis was performed on the data for the first time to reduce the three dimensions, red, green, and blue, to one dimension. The effective extraction parameters were optimized. The limit of detection and limit of quantification were 0.1 µg mL-1. Intra- and inter-assay relative standard deviations ranged between 2.0 and 2.3 % and 3.1-3.7 %, respectively. The calibration range was studied between 0.1 and 25 µg mL-1 (R2 = 0.9814).
Collapse
Affiliation(s)
- Farnaz Zaroudi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran
| | - Behrooz Nasihatkon
- Faculty of Computer Engineering, K.N. Toosi University of Technology, Tehran, Iran
| | | | - Ali Reza Fakhari
- Department of Chemistry, Shahid Beheshti University, G. V., P.O. Box 1983963113 Evin, Tehran, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran.
| |
Collapse
|
3
|
Ocaña-González JA, Aranda-Merino N, Pérez-Bernal JL, Ramos-Payán M. Solid supports and supported liquid membranes for different liquid phase microextraction and electromembrane extraction configurations. A review. J Chromatogr A 2023; 1691:463825. [PMID: 36731330 DOI: 10.1016/j.chroma.2023.463825] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 01/09/2023] [Accepted: 01/22/2023] [Indexed: 01/29/2023]
Abstract
Liquid phase microextraction (LPME) and electromembrane microextraction (EME) can be considered as two of the most popular techniques in sample treatment today. Both techniques can be configurated as membrane-assisted techniques to carry out the extraction. These supports provide the required geometry and stability on the contact surface between two phases (donor and acceptor) and improve the reproducibility of sample treatment techniques. These solid support pore space, once is filled with organic solvents, act as a selective barrier acting as a supported liquid membrane (SLM). The SLM nature is a fundamental parameter, and its selection is critical to carry out successful extractions. There are numerous SLMs that have been successfully employed in a wide variety of application fields. The latter is due to the specificity of the selected organic solvents, which allows the extraction of compounds of a very different nature. In the last decade, solid supports and SLM have evolved towards "green" and environmentally friendly materials and solvents. In this review, solid supports implemented in LPME and EME will be discussed and summarized, as well as their applications. Moreover, the advances and modifications of the solid supports and the SLMs to improve the extraction efficiencies, recoveries and enrichment factors are discussed. Hollow fiber and flat membranes, including microfluidic systems, will be considered depending on the technique, configuration, or device used.
Collapse
Affiliation(s)
- Juan Antonio Ocaña-González
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - Noemí Aranda-Merino
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - Juan Luis Pérez-Bernal
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain.
| |
Collapse
|
4
|
Tahmasebi E, Mirzania R. Polyaniline-polycaprolactone electrospun nanofibrous mat: new polymeric support with anion exchange characteristic for immobilizing liquid membrane in efficient on-chip electromembrane extraction of polar acidic drugs. Mikrochim Acta 2022; 190:2. [PMID: 36460870 DOI: 10.1007/s00604-022-05581-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 11/15/2022] [Indexed: 12/04/2022]
Abstract
The potential of application of an electrospun nanofiber sheet as new polymeric support for immobilizing the liquid membrane, instead of a common commercial polypropylene sheet, in on-chip electromembrane extraction (EME) of some acidic polar drugs followed by HPLC with ultraviolet detection is presented. The nanofiber sheet was prepared by electrospinning a mixture of polycaprolactone and polyaniline. The successful synthesis of the electrospun nanofiber sheet was confirmed by field emission-scanning electron microscopy, energy-dispersive X-ray spectroscopy, elemental mapping, and atomic force microscopy. Several parameters affecting the efficiency of the microextraction method, including pHs of the donor and acceptor phases, applied voltage, sample flow rate, phosphate content of the acceptor phase, and sample volume, were investigated and optimized. After optimization, the linearity range of 0.5-250.0 µg L-1 and detection limits of 0.2-1.0 µg L-1 were obtained for the analytes. The extraction recovery values and preconcentration factors were 10.7-55.3% and 16-83, respectively. The presence of polyaniline in the composition of the nanofibers significantly improved the extraction efficiency of the polar acidic drugs due to providing the possibility of various interactions with the target analytes such as hydrogen bonding, π-stacking, and anion exchange. The obtained results demonstrate the excellent efficiency of the synthesized electrospun nanofibrous mat as a novel support membrane for immobilizing 1-octanol and as an interactive substrate for electromembrane extraction of acidic polar drugs. Eventually, the proposed on-chip EME method exhibits acceptable precision (relative standard deviations less than 9.7% (n = 3)) and good accuracy (86-112%) for determining the target analytes in the plasma samples.
Collapse
Affiliation(s)
- Elham Tahmasebi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran.
| | - Roya Mirzania
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran
| |
Collapse
|
5
|
Chen M, Qin Y, Wang S, Liu S, Zhao G, Lu H, Cui H, Cai J, Wang X, Yan Q, Hua C, Xie F, Wan L. Electromembrane extraction of nicotine in inhaled aerosols from tobacco cigarettes, electronic cigarettes, and heated tobacco products. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1208:123391. [PMID: 35908439 DOI: 10.1016/j.jchromb.2022.123391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/28/2022] [Accepted: 07/23/2022] [Indexed: 11/30/2022]
Abstract
Heated tobacco products and electronic cigarettes are considered as alternatives to traditional tobacco cigarettes. However, it is crucial to monitor and compare the nicotine concentration in inhaled aerosols from these tobacco products, owing to the addictive nature and adverse effects of nicotine on human health. This study aimed to provide an electromembrane extraction (EME) combined liquid chromatography method to extract and determine nicotine in different inhaled aerosols. EME showed high extraction efficiency, selectivity, and sample clean-up capability. Under the optimal parameters, the linear range for nicotine was 0.1-200 mg L-1 (r2 > 0.9998), and the limit of detection was 0.02 mg L-1. Good precision was obtained with the intra- and inter-day relative standard deviations of 2.2 % and 2.8 %, respectively. Repeatability was satisfactory (<7.7 %), and recoveries ranged from 81.0 % to 112.8 %. Finally, this method has been successfully used for the determination and comparison of nicotine in aerosols from these three tobacco products.
Collapse
Affiliation(s)
- Mantang Chen
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Yaqiong Qin
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Sheng Wang
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Shaofeng Liu
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Ge Zhao
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Hongliang Lu
- Technology Center of China Tobacco Fujian Industrial Co., LTD, Binshui Road #298, Xiamen 361021, PR China
| | - Huapeng Cui
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Junlan Cai
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Xiaoyu Wang
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Quanping Yan
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Chenfeng Hua
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China
| | - Fuwei Xie
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, PR China.
| | - Libin Wan
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, PR China.
| |
Collapse
|
6
|
|