1
|
Vinnikov VA. Effect of changing the radiation dose range on the in vitro cytogenetic dose response to gamma-rays. Int J Radiat Biol 2024; 100:875-889. [PMID: 38647504 DOI: 10.1080/09553002.2024.2338511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 03/27/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE To examine the distortion of the linear quadratic (LQ) model of in vitro cytogenetic dose response over an extended range of γ-ray doses by analyzing the available literature data, and to establish the dose ranges, in which the LQ dose response curve (DRC) can be most accurately fitted for biological dosimetry. MATERIALS AND METHODS Data on yields of dicentrics (Dic) or dicentrics plus centric rings (Dic + CR) induced in vitro in human lymphocytes by acute γ-rays were extracted from 108 open sources. The overall dose response dataset in the dose range up to 50 Gy was fitted to a fractional-rational (FR) model, which included a 'basic' LQ function in the numerator, and a reduction factor dependent on the square of the dose in the denominator. Cytogenetic dose response data obtained at Grigoriev Institute for Medical Radiology, Kharkiv, Ukraine (GIMRO) in the range 0.1 - 20.3 Gy acute γ-rays were fitted to the LQ model with the progressive changing minimum or maximum radiation dose. RESULTS The overall dose response, as expected, followed the LQ function in the dose range ≤5 Gy, but in the extended dose range appeared to be S-shaped, with intensive saturation and a plateau at doses ≥22 Gy. Coefficients of the 'basic' LQ equation in FR model were very close to many published DRCs; calculated asymptote was 17. Fitting of the GIMRO dataset to the LQ model with the shift of the dose range showed the increase in linear coefficient with the increment of either minimum or maximum radiation dose, while the decline of the quadratic coefficient was regulated mostly by the increase of the highest dose. The best goodness of fit, assessed by lower χ2 values, occurred for dose ranges 0.1 - 1.0 Gy; 0.5 - 5.9 Gy; 1.0 - 7.8 Gy; 2.0 - 9.6 Gy, 3.9 - 16.4 Gy and 5.9 - 20.3 Gy. The 'see-saw' effect in changes of LQ coefficients was confirmed by re-fitting datasets published by other laboratories. CONCLUSIONS The classical LQ model with fixed coefficients appears to have limited applicability for cytogenetic dosimetry at radiation doses >5 Gy due to the saturation of the dose response. Different response of the LQ coefficients to the changes of the dose range must be considered during the DRC construction. Proper selection of minimum and maximum dose in calibration experiments makes it possible to improve the goodness of fit of the LQ DRC.
Collapse
Affiliation(s)
- Volodymyr A Vinnikov
- S.P. Grigoriev Institute for Medical Radiology and Oncology, National Academy of Medical Science of Ukraine, Kharkiv, Ukraine
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic
| |
Collapse
|
2
|
Meher PK, Lundholm L, Wojcik A. Fluorescence in situ hybridisation for interphase chromosomal aberration-based biological dosimetry. RADIATION PROTECTION DOSIMETRY 2023; 199:1501-1507. [PMID: 37721087 PMCID: PMC10505941 DOI: 10.1093/rpd/ncac264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/30/2022] [Accepted: 11/16/2022] [Indexed: 09/19/2023]
Abstract
Metaphase spreads stained with Giemsa or painted with chromosome-specific probes by fluorescence in situ hybridisation (FISH) have been in use since long for retrospective dose assessment (biological dosimetry). However, in cases of accidental exposure to ionising radiation, the culturing of lymphocytes to obtain metaphase chromosomes and analysis of chromosomal aberrations is time-consuming and problematic after high radiation doses. Similarly, analysing chromosomal damage in G0/G1 cells or nondividing cells by premature chromosome condensation is laborious. Following large-scale radiological emergencies, the time required for analysis is more important than precision of dose estimate. Painting of whole chromosomes using chromosome-specific probes in interphase nuclei by the FISH technique will eliminate the time required for cell culture and allow a fast dose estimate, provided that a meaningful dose-response can be obtained by scoring the number of chromosomal domains visible in interphase nuclei. In order to test the applicability of interphase FISH for quick biological dosimetry, whole blood from a healthy donor was irradiated with 8 Gy of gamma radiation. Irradiated whole blood was kept for 2 h at 37°C to allow DNA repair and thereafter processed for FISH with probes specific for Chromosomes-1 and 2. Damaged chromosomal fragments, distinguished by extra color domains, were observed in interphase nuclei of lymphocytes irradiated with 8 Gy. These fragments were efficiently detected and quantified by the FISH technique utilising both confocal and single plane fluorescence microscopy. Furthermore, a clear dose-response curve for interphase fragments was achieved following exposure to 0, 1, 2, 4 and 8 Gy of gamma radiation. These results demonstrate interphase FISH as a promising test for biodosimetry and for studying cytogenetic effects of radiation in nondividing cells.
Collapse
Affiliation(s)
- Prabodha Kumar Meher
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Lovisa Lundholm
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Andrzej Wojcik
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
- Institute of Biology, Jan Kochanowski University, Kielce, Poland
| |
Collapse
|
3
|
Beaton-Green LA, Mayenburg JM, Marro L, Hassan EM, Cuadros Sanchez S, Darwish R, Lachapelle S, Adam N, Burtt JJ, Van Den Hanenberg C, Rodrigues MA, Wang Q, Brenner DJ, Turner HC, Wilkins RC. Application of the Cytokinesis-Block Micronucleus Assay for High-Dose Exposures Using Imaging Flow Cytometry. Cytogenet Genome Res 2023; 163:131-142. [PMID: 37527635 DOI: 10.1159/000532124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 07/20/2023] [Indexed: 08/03/2023] Open
Abstract
The cytokinesis-block micronucleus assay is a well-established method to assess radiation-induced genetic damage in human cells. This assay has been adapted to imaging flow cytometry (IFC), allowing automated analysis of many cells, and eliminating the need to create microscope slides. Furthermore, to improve the efficiency of assay performance, a small-volume method previously developed was employed. Irradiated human blood samples were cultured, stained, and analyzed by IFC to produce images of the cells. Samples were run using both manual and 96-well plate automated acquisition. Multiple parameter-based image features were collected for each sample, and the results were compared to confirm that these acquisition methods are functionally identical. This paper details the multi-parametric analysis developed and the resulting calibration curves up to 10 Gy. The calibration curves were created using a quadratic random coefficient model with Poisson errors, as well as a logistic discriminant function. The curves were then validated with blinded, irradiated samples, using relative bias and relative mean square error. Overall, the accuracy of the dose estimates was adequate for triage dosimetry (within 1 Gy of the true dose) over 90% of the time for lower doses and about half the time for higher doses, with the lowest success rate between 5 and 6 Gy where the calibration curve reached its peak and there was the smallest change in MN/BNC with dose. This work describes the application of a novel multi-parametric analysis that fits the calibration curves and allows dose estimates up to 10 Gy, which were previously limited to 4 Gy. Furthermore, it demonstrates that the results from samples acquired manually and with the autosampler are functionally similar.
Collapse
Affiliation(s)
- Lindsay A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Jessica M Mayenburg
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Leonora Marro
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Eman M Hassan
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Sarita Cuadros Sanchez
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Riham Darwish
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Sylvie Lachapelle
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Nadine Adam
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Julie J Burtt
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Cyndi Van Den Hanenberg
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | | | - Qi Wang
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - Ruth C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| |
Collapse
|
4
|
Investigation of DNA Damage and Cell-Cycle Distribution in Human Peripheral Blood Lymphocytes under Exposure to High Doses of Proton Radiotherapy. BIOLOGY 2021; 10:biology10020111. [PMID: 33546318 PMCID: PMC7913503 DOI: 10.3390/biology10020111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 01/29/2021] [Accepted: 01/31/2021] [Indexed: 12/13/2022]
Abstract
This study systematically investigates how a single high-dose therapeutic proton beam versus X-rays influences cell-cycle phase distribution and DNA damage in human peripheral blood lymphocytes (HPBLs). Blood samples from ten volunteers (both male and female) were irradiated with doses of 8.00, 13.64, 15.00, and 20.00 Gy of 250 kV X-rays or 60 MeV protons. The dose-effect relations were calculated and distributed by plotting the frequencies of DNA damage of excess Premature Chromosome Condensation (PCC) fragments and rings in the G2/M phase, obtained via chemical induction with calyculin A. The Papworth's u test was used to evaluate the distribution of DNA damage. The study shows that high doses of protons induce HPBL DNA damage in the G2/M phase differently than X-rays do. The results indicate a different distribution of DNA damage following high doses of irradiation with protons versus photons between donors, types of radiation, and doses. The proliferation index confirms the impact of high doses of mitosis and the influence of radiotherapy type on the different HPBL response. The results illuminate the cellular and molecular mechanisms that underlie differences in the distribution of DNA damage and cell-cycle phases; these findings may yield an improvement in the efficacy of the radiotherapies used.
Collapse
|
5
|
Vinnikov V, Hande MP, Wilkins R, Wojcik A, Zubizarreta E, Belyakov O. Prediction of the Acute or Late Radiation Toxicity Effects in Radiotherapy Patients Using Ex Vivo Induced Biodosimetric Markers: A Review. J Pers Med 2020; 10:E285. [PMID: 33339312 PMCID: PMC7766345 DOI: 10.3390/jpm10040285] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 12/02/2020] [Accepted: 12/11/2020] [Indexed: 12/14/2022] Open
Abstract
A search for effective methods for the assessment of patients' individual response to radiation is one of the important tasks of clinical radiobiology. This review summarizes available data on the use of ex vivo cytogenetic markers, typically used for biodosimetry, for the prediction of individual clinical radiosensitivity (normal tissue toxicity, NTT) in cells of cancer patients undergoing therapeutic irradiation. In approximately 50% of the relevant reports, selected for the analysis in peer-reviewed international journals, the average ex vivo induced yield of these biodosimetric markers was higher in patients with severe reactions than in patients with a lower grade of NTT. Also, a significant correlation was sometimes found between the biodosimetric marker yield and the severity of acute or late NTT reactions at an individual level, but this observation was not unequivocally proven. A similar controversy of published results was found regarding the attempts to apply G2- and γH2AX foci assays for NTT prediction. A correlation between ex vivo cytogenetic biomarker yields and NTT occurred most frequently when chromosome aberrations (not micronuclei) were measured in lymphocytes (not fibroblasts) irradiated to relatively high doses (4-6 Gy, not 2 Gy) in patients with various grades of late (not early) radiotherapy (RT) morbidity. The limitations of existing approaches are discussed, and recommendations on the improvement of the ex vivo cytogenetic testing for NTT prediction are provided. However, the efficiency of these methods still needs to be validated in properly organized clinical trials involving large and verified patient cohorts.
Collapse
Affiliation(s)
- Volodymyr Vinnikov
- S.P. Grigoriev Institute for Medical Radiology and Oncology, National Academy of Medical Science of Ukraine, 61024 Kharkiv, Ukraine
| | - Manoor Prakash Hande
- Department of Physiology, Yong Loo Lin School of Medicine, National University of Singapore, MD9, 2 Medical Drive, Singapore 117593, Singapore;
| | - Ruth Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa, ON K1A 1C1, Canada;
| | - Andrzej Wojcik
- Centre for Radiation Protection Research, MBW Department, Stockholm University, Svante Arrhenius väg 20C, Room 515, 10691 Stockholm, Sweden;
| | - Eduardo Zubizarreta
- Section of Applied Radiation Biology and Radiotherapy, Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria;
| | - Oleg Belyakov
- Section of Applied Radiation Biology and Radiotherapy, Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria;
| |
Collapse
|
6
|
Pujol-Canadell M, Perrier JR, Cunha L, Shuryak I, Harken A, Garty G, Brenner DJ. Cytogenetically-based biodosimetry after high doses of radiation. PLoS One 2020; 15:e0228350. [PMID: 32320391 PMCID: PMC7176141 DOI: 10.1371/journal.pone.0228350] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 01/13/2020] [Indexed: 11/18/2022] Open
Abstract
Dosimetry is an important tool for triage and treatment planning following any radiation exposure accident, and biological dosimetry, which estimates exposure dose using a biological parameter, is a practical means of determining the specific dose an individual receives. The cytokinesis-blocked micronucleus assay (CBMN) is an established biodosimetric tool to measure chromosomal damage in mitogen-stimulated human lymphocytes. The CBMN method is especially valuable for biodosimetry in triage situations thanks to simplicity in scoring and adaptability to high-throughput automated sample processing systems. While this technique produces dose-response data which fit very well to a linear-quadratic model for exposures to low linear energy transfer (LET) radiation and for doses up for 5 Gy, limitations to the accuracy of this method arise at larger doses. Accuracy at higher doses is limited by the number of cells reaching mitosis. Whereas it would be expected that the yield of micronuclei increases with the dose, in many experiments it has been shown to actually decrease when normalized over the total number of cells. This variation from a monotonically increasing dose response poses a limitation for retrospective dose reconstruction. In this study we modified the standard CBMN assay to increase its accuracy following exposures to higher doses of photons or a mixed neutron-photon beam. The assay is modified either through inhibitions of the G2/M and spindle checkpoints with the addition of caffeine and/or ZM447439 (an Aurora kinase inhibitor), respectively to the blood cultures at select times during the assay. Our results showed that caffeine addition improved assay performance for photon up to 10 Gy. This was achieved by extending the assay time from the typical 70 h to just 74 h. Compared to micronuclei yields without inhibitors, addition of caffeine and ZM447439 resulted in improved accuracy in the detection of micronuclei yields up to 10 Gy from photons and 4 Gy of mixed neutrons-photons. When the dose-effect curves were fitted to take into account the turnover phenomenon observed at higher doses, best fitting was achieved when the combination of both inhibitors was used. These techniques permit reliable dose reconstruction after high doses of radiation with a method that can be adapted to high-throughput automated sample processing systems.
Collapse
Affiliation(s)
- Monica Pujol-Canadell
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, United States of America
| | - Jay R. Perrier
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, United States of America
| | - Lidia Cunha
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, United States of America
| | - Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, United States of America
| | - Andrew Harken
- Radiological Research Accelerator Facility, Irvington, NY, United States of America
| | - Guy Garty
- Radiological Research Accelerator Facility, Irvington, NY, United States of America
| | - David J. Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, United States of America
| |
Collapse
|
7
|
Rodrigues MA, Probst CE, Beaton-Green LA, Wilkins RC. Optimized automated data analysis for the cytokinesis-block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry. Cytometry A 2016; 89:653-62. [PMID: 27272602 PMCID: PMC5089661 DOI: 10.1002/cyto.a.22887] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Revised: 05/05/2016] [Accepted: 05/10/2016] [Indexed: 01/23/2023]
Abstract
The cytokinesis-block micronucleus (CBMN) assay is a well-established technique that can be employed in triage radiation biodosimetry to estimate whole body doses of radiation to potentially exposed individuals through quantitation of the frequency of micronuclei (MN) in binucleated lymphocyte cells (BNCs). The assay has been partially automated using traditional microscope-based methods and most recently has been modified for application on the ImageStream(X) (IS(X) ) imaging flow cytometer. This modification has allowed for a similar number of BNCs to be automatically scored as compared to traditional microscopy in a much shorter time period. However, the MN frequency measured was much lower than both manual and automated slide-based methods of performing the assay. This work describes the optimized analysis template which implements newly developed functions in the IDEAS(®) data analysis software for the IS(X) that enhances specificity for BNCs and increases the frequency of scored MN. A new dose response calibration curve is presented in which the average rate of MN per BNC is of similar magnitude to those presented in the literature using automated CBMN slide scoring methods. In addition, dose estimates were generated for nine irradiated, blinded samples and were found to be within ±0.5 Gy of the delivered dose. Results demonstrate that the improved identification accuracy for MN and BNCs in the IS(X) -based version of the CBMN assay will translate to increased accuracy when estimating unknown radiation doses received by exposed individuals following large-scale radiological or nuclear emergencies. © 2016 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC.
Collapse
Affiliation(s)
- M A Rodrigues
- Amnis - MilliporeSigma, Seattle, WA, 98119.,Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - C E Probst
- Amnis - MilliporeSigma, Seattle, WA, 98119
| | - L A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - R C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| |
Collapse
|
8
|
Beinke C, Port M, Riecke A, Ruf CG, Abend M. Adaption of the Cytokinesis-Block Micronucleus Cytome Assay for Improved Triage Biodosimetry. Radiat Res 2016; 185:461-72. [DOI: 10.1667/rr14294.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- C. Beinke
- Bundeswehr Institute of Radiobiology, 80937 Munich, Germany
| | - M. Port
- Bundeswehr Institute of Radiobiology, 80937 Munich, Germany
| | - A. Riecke
- Department of Hematology, Federal Armed Forces Hospital, 89081 Ulm, Germany; and
| | - C. G. Ruf
- Department of Urology, Federal Armed Forces Hospital, 56072 Koblenz, Germany
| | - M. Abend
- Bundeswehr Institute of Radiobiology, 80937 Munich, Germany
| |
Collapse
|
9
|
Nakamura A, Monzen S, Takasugi Y, Wojcik A, Mariya Y. Application of cell sorting for enhancing the performance of the cytokinesis-block micronucleus assay. JOURNAL OF RADIATION RESEARCH 2016; 57:121-126. [PMID: 26826197 PMCID: PMC4795957 DOI: 10.1093/jrr/rrv103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Revised: 11/16/2015] [Accepted: 12/15/2015] [Indexed: 06/05/2023]
Abstract
Among the numerous methods available to assess genotoxicity, the cytokinesis-block micronucleus (CBMN) assay is very popular due its relative simplicity and power to detect both clastogenic and aneugenic compounds. A problem with the CBMN assay is that all DNA damaging agents also inhibit the ability of cells to progress through mitosis, leading to a low number of binucleated cells (BNCs). One method to resolve this issue is to ensure a sufficient proportion of BNCs in the samples. In the current study, the applicability of a cell sorting system capable of isolating cell fractions containing abundant BNCs was investigated. Furthermore, to investigate the relationship between the cell division delay due to radiation exposure and the generation of BNCs and micronuclei (MN), we assessed a series of lag times between radiation exposure and addition of cytochalasin-B (Cyt-B). Cells from the human chronic myelogenous leukemia cell line K562 were exposed to X-rays (2 Gy and 4 Gy), and Cyt-B was subsequently added at 0, 6 and 12 h following irradiation. After treatment with Cyt-B for 24 h, the percentage of BNCs, the MN frequency and the cell cycle distribution were analyzed. In addition, cells displaying the DNA contents corresponding to BNCs were isolated and analyzed. The results indicate that applying the cell sorter to the CBMN assay increased the percentage of BNCs compared with the standard method. Thus, this technique is a promising way of enhancing the capacity of the CBMN assay.
Collapse
Affiliation(s)
- Ayumi Nakamura
- Department of Radiological Life Sciences, Division of Medical Life Sciences, Hirosaki University Graduate School of Health Sciences, Hirosaki, Aomori 036-8564, Japan
| | - Satoru Monzen
- Department of Radiological Life Sciences, Division of Medical Life Sciences, Hirosaki University Graduate School of Health Sciences, Hirosaki, Aomori 036-8564, Japan
| | - Yuki Takasugi
- Department of Radiological Life Sciences, Division of Medical Life Sciences, Hirosaki University Graduate School of Health Sciences, Hirosaki, Aomori 036-8564, Japan
| | - Andrzej Wojcik
- Centre for Radiation Protection Research, MBW Department, Stockholm University, SE-106 91, Stockholm, Sweden
| | - Yasushi Mariya
- Department of Radiological Life Sciences, Division of Medical Life Sciences, Hirosaki University Graduate School of Health Sciences, Hirosaki, Aomori 036-8564, Japan
| |
Collapse
|
10
|
Rodrigues MA, Beaton-Green LA, Wilkins RC. Validation of the Cytokinesis-block Micronucleus Assay Using Imaging Flow Cytometry for High Throughput Radiation Biodosimetry. HEALTH PHYSICS 2016; 110:29-36. [PMID: 26606062 DOI: 10.1097/hp.0000000000000371] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The cytokinesis-block micronucleus assay can be employed in triage radiation biodosimetry to determine the dose of radiation to an exposed individual by quantifying the frequency of micronuclei in binucleated lymphocyte cells. Partially automated analysis of the assay has been applied to traditional microscope-based methods, and most recently, the assay has been adapted to an automated imaging flow cytometry method. This method is able to automatically score a larger number of binucleated cells than are typically scored by microscopy. Whole blood samples were irradiated, divided into 2 mL and 200 μL aliquots, cultured for 48 h and 72 h, and processed to generate calibration curves from 0-4 Gy. To validate the method for use in radiation biodosimetry, nine separate whole blood samples were then irradiated to known doses, blinded, and processed. Results indicate that dose estimations can be determined to within ±0.5 Gy of the delivered dose after only 48 h of culture time with an initial blood volume of 200 μL. By performing the cytokinesis-block micronucleus assay using imaging flow cytometry, a significant reduction in the culture time and volume requirements is possible, which greatly increases the applicability of the assay in high throughput triage radiation biodosimetry.
Collapse
Affiliation(s)
- Matthew A Rodrigues
- *Consumer and Clinical Radiation Protection Bureau, Health Canada, 775 Brookfield Rd., K1A 1C1, Ottawa, Ontario, Canada; †Department of Physics, Carleton University, 1125 Colonel By Drive, K1S 5B6, Ottawa, Ontario, Canada
| | | | | |
Collapse
|
11
|
Cortés-Gutiérrez EI, Dávila-Rodríguez MI, Cerda-Flores RM, Fernández JL, López-Fernández C, Gosálvez J. Use of the DBD-FISH technique for detecting DNA breakage in response to high doses of X-rays. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:713-718. [PMID: 24957017 DOI: 10.1007/s00411-014-0555-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Accepted: 06/13/2014] [Indexed: 06/03/2023]
Abstract
The aim of this study was to generate a dose-response curve using the DNA breakage detection-fluorescent in situ hybridization (DBD-FISH) test as a biomarker of initial genetic effects induced by high doses of X-rays. A dose-response curve was obtained by measuring the ex vivo responses to increasing doses (0-50 Gy) of X-rays in the peripheral blood lymphocytes of ten healthy donors. The overall dose-response curve was constructed using integrated density (ID; area × fluorescence intensity) as a measure of genetic damage induced by irradiation. The correlation coefficient was high (r = 0.934, b(0) = 10.408, and b(1) = 0.094). One-way ANOVA with the Student-Newman-Keuls test for multiple comparisons showed significant differences among the average ln ID values according to dose. Our results suggest the usefulness of the DBD-FISH technique for measuring intrinsic individual cellular radio sensitivity ex vivo.
Collapse
Affiliation(s)
- Elva I Cortés-Gutiérrez
- Department of Genetics, Centro de Investigación Biomédica del Noreste, Instituto Mexicano del Seguro Social, IMSS, C.P. 64720, Monterrey, NL, Mexico,
| | | | | | | | | | | |
Collapse
|
12
|
Rodrigues MA, Beaton-Green LA, Kutzner BC, Wilkins RC. Multi-parameter dose estimations in radiation biodosimetry using the automated cytokinesis-block micronucleus assay with imaging flow cytometry. Cytometry A 2014; 85:883-93. [PMID: 25154929 DOI: 10.1002/cyto.a.22511] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2014] [Revised: 05/08/2014] [Accepted: 07/03/2014] [Indexed: 11/08/2022]
Abstract
The cytokinesis-block micronucleus (CBMN) assay is an established technique in radiation biological dosimetry for estimating the dose to an individual by measuring the frequency of micronuclei (MN) in binucleated lymphocyte cells (BNCs). The assay has been partially automated using slide-scoring algorithms, but an automated multiparameter method without the need of the slide-making procedure would be advantageous to further increase throughput for application in mass casualty events. The development of the ImageStreamX (ISX) imaging flow cytometer has made it possible to adapt the CBMN assay to an automated imaging flow cytometry (FCM) method. The protocol and analysis presented in this work tailor and expand the assay to a multiparameter biodosimetry tool. Ex vivo irradiated whole blood samples were cultured, processed, and analyzed on the ISX and BNCs, MN, and mononuclear cells were imaged, identified, and enumerated automatically and simultaneously. Details on development of the method, gating strategy, and dose response curves generated for the rate of MN per BNC, percentage of mononuclear cells as well as the replication index are presented. Results indicate that adapting the CBMN assay for use in imaging FCM has produced a rapid, robust, multiparameter analysis method with higher throughput than is currently available with standard microscopy. We conclude that the ISX-CBMN method may be an advantageous tool following a radiological event where triage biodosimetry must be performed on a large number of casualties.
Collapse
Affiliation(s)
- M A Rodrigues
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Ontario, Canada; Department of Physics, Carleton University, K1S 5B6, Ottawa, Ontario, Canada
| | | | | | | |
Collapse
|
13
|
Lyulko OV, Garty G, Randers-Pehrson G, Turner HC, Szolc B, Brenner DJ. Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system. Radiat Res 2014; 181:146-61. [PMID: 24502354 PMCID: PMC4011502 DOI: 10.1667/rr13441.1] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The development of, and results from an image analysis system are presented for automated detection and scoring of micronuclei in human peripheral blood lymphocytes. The system is part of the Rapid Automated Biodosimetry Tool, which was developed at the Center for High-Throughput Minimally Invasive Radiation Biodosimetry for rapid radiation dose assessment of many individuals based on single fingerstick samples of blood. Blood lymphocytes were subjected to the cytokinesis-block micronucleus assay and the images of cell cytoplasm and nuclei are analyzed to estimate the frequency of micronuclei in binucleated cells. We describe an algorithm that is based on dual fluorescent labeling of lymphocytes with separate analysis of images of cytoplasm and nuclei. To evaluate the performance of the system, blood samples of seven healthy donors were irradiated in vitro with doses from 0-10 Gy and dose-response curves of micronuclei frequencies were generated. To establish the applicability of the system to the detection of high doses, the ratios of mononucleated cells to binucleated cells were determined for three of the donors. All of the dose-response curves generated automatically showed clear dose dependence and good correlation (R(2) from 0.914-0.998) with the results of manual scoring.
Collapse
Affiliation(s)
- Oleksandra V. Lyulko
- Center for Radiological Research, Columbia University Medical Center, New York, New York
| | - Guy Garty
- Center for Radiological Research, Columbia University Medical Center, New York, New York
| | | | - Helen C. Turner
- Center for Radiological Research, Columbia University Medical Center, New York, New York
| | - Barbara Szolc
- Center for Radiological Research, Columbia University Medical Center, New York, New York
- David B. Kriser Dental Center, New York University College of Dentistry, New York, New York
| | - David J. Brenner
- Center for Radiological Research, Columbia University Medical Center, New York, New York
| |
Collapse
|