• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4616374)   Today's Articles (3144)   Subscriber (49395)
For: Hong C, Lee DH, Han BS. Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI. Magn Reson Imaging 2014;32:786-90. [PMID: 24698340 DOI: 10.1016/j.mri.2014.02.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2013] [Revised: 02/03/2014] [Accepted: 02/03/2014] [Indexed: 11/29/2022]
Number Cited by Other Article(s)
1
Chen X, Zhao Y, Court LE, Wang H, Pan T, Phan J, Wang X, Ding Y, Yang J. SC-GAN: Structure-completion generative adversarial network for synthetic CT generation from MR images with truncated anatomy. Comput Med Imaging Graph 2024;113:102353. [PMID: 38387114 DOI: 10.1016/j.compmedimag.2024.102353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 12/14/2023] [Accepted: 02/04/2024] [Indexed: 02/24/2024]
2
Zhao Y, Wang H, Yu C, Court LE, Wang X, Wang Q, Pan T, Ding Y, Phan J, Yang J. Compensation cycle consistent generative adversarial networks (Comp-GAN) for synthetic CT generation from MR scans with truncated anatomy. Med Phys 2023;50:4399-4414. [PMID: 36698291 PMCID: PMC10356747 DOI: 10.1002/mp.16246] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 01/27/2023]  Open
3
Lu L, Yang X, Raterman B, Jiang X, Meineke M, Grecula J, Blakaj D, Palmer J, Raval R, Thomas E, Hintenlang D, Gupta N. Assessment of MRI image distortion based on 6 consecutive years of annual QAs and measurements on 14 MRI scanners used for radiation therapy. J Appl Clin Med Phys 2022;24:e13843. [PMID: 36385457 PMCID: PMC9859981 DOI: 10.1002/acm2.13843] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 09/30/2022] [Accepted: 10/21/2022] [Indexed: 11/18/2022]  Open
4
Schüler E, Mallozzi R, Levy J, Hristov D. Technical Note: Extended field-of-view (FOV) MRI distortion determination through multi-positional phantom imaging. J Appl Clin Med Phys 2020;21:322-332. [PMID: 33073909 PMCID: PMC7701113 DOI: 10.1002/acm2.13065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2020] [Revised: 08/31/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022]  Open
5
Peerlings J, Compter I, Janssen F, Wiggins CJ, Postma AA, Mottaghy FM, Lambin P, Hoffmann AL. Characterizing geometrical accuracy in clinically optimised 7T and 3T magnetic resonance images for high-precision radiation treatment of brain tumours. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2019;9:35-42. [PMID: 33458423 PMCID: PMC7807620 DOI: 10.1016/j.phro.2018.12.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 11/23/2018] [Accepted: 12/05/2018] [Indexed: 11/27/2022]
6
Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study. Eur Radiol 2018;29:2770-2782. [PMID: 30519932 PMCID: PMC6510873 DOI: 10.1007/s00330-018-5863-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 08/25/2018] [Accepted: 10/25/2018] [Indexed: 11/30/2022]
7
Kim M, Jung NY, Park CK, Chang WS, Jung HH, Chang JW. Estimating Accurate Target Coordinates with Magnetic Resonance Images by Using Multiple Phase-Encoding Directions during Acquisition. Stereotact Funct Neurosurg 2018;96:113-119. [PMID: 29860250 DOI: 10.1159/000488396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 03/06/2018] [Indexed: 11/19/2022]
8
Prospective analysis of in vivo landmark point-based MRI geometric distortion in head and neck cancer patients scanned in immobilized radiation treatment position: Results of a prospective quality assurance protocol. Clin Transl Radiat Oncol 2017;7:13-19. [PMID: 29594224 PMCID: PMC5862642 DOI: 10.1016/j.ctro.2017.09.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Revised: 09/09/2017] [Accepted: 09/11/2017] [Indexed: 11/23/2022]  Open
9
Price RG, Kadbi M, Kim J, Balter J, Chetty IJ, Glide-Hurst CK. Technical Note: Characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM. Med Phys 2016;42:5955-60. [PMID: 26429270 DOI: 10.1118/1.4930245] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
10
Weygand J, Fuller CD, Ibbott GS, Mohamed ASR, Ding Y, Yang J, Hwang KP, Wang J. Spatial Precision in Magnetic Resonance Imaging-Guided Radiation Therapy: The Role of Geometric Distortion. Int J Radiat Oncol Biol Phys 2016;95:1304-16. [PMID: 27354136 DOI: 10.1016/j.ijrobp.2016.02.059] [Citation(s) in RCA: 113] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Revised: 02/05/2016] [Accepted: 02/25/2016] [Indexed: 12/11/2022]
11
Walker A, Liney G, Holloway L, Dowling J, Rivest-Henault D, Metcalfe P. Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom. Med Phys 2015;42:1982-91. [PMID: 25832089 DOI: 10.1118/1.4915920] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
12
Kim J, Glide-Hurst C, Doemer A, Wen N, Movsas B, Chetty IJ. Implementation of a Novel Algorithm For Generating Synthetic CT Images From Magnetic Resonance Imaging Data Sets for Prostate Cancer Radiation Therapy. Int J Radiat Oncol Biol Phys 2015;91:39-47. [DOI: 10.1016/j.ijrobp.2014.09.015] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Revised: 08/15/2014] [Accepted: 09/10/2014] [Indexed: 10/24/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA