Uzun D, Yildirim DK, Bruce CG, Halaby RN, Jaimes A, Potersnak A, Ramasawmy R, Campbell-Washburn A, Lederman RJ, Kocaturk O. Interventional device tracking under MRI via alternating current controlled inhomogeneities. Magn Reson Med 2024; 92:346-360. [PMID: 38394163 PMCID: PMC11055668 DOI: 10.1002/mrm.30031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/10/2024] [Accepted: 01/12/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.
Collapse
Affiliation(s)
- Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rim N. Halaby
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Andi Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
2
|
Yildirim DK, Uzun D, Bruce CG, Khan JM, Rogers T, Schenke WH, Ramasawmy R, Campbell-Washburn A, Herzka D, Lederman RJ, Kocaturk O. An interventional MRI guidewire combining profile and tip conspicuity for catheterization at 0.55T. Magn Reson Med 2023; 89:845-858. [PMID: 36198118 PMCID: PMC9712240 DOI: 10.1002/mrm.29466] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 08/04/2022] [Accepted: 09/02/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Daniel Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
3
|
Nijsink H, Overduin CG, Willems LH, Warlé MC, Fütterer JJ. Current State of MRI-Guided Endovascular Arterial Interventions: A Systematic Review of Preclinical and Clinical Studies. J Magn Reson Imaging 2022; 56:1322-1342. [PMID: 35420239 PMCID: PMC9790618 DOI: 10.1002/jmri.28205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 04/04/2022] [Accepted: 04/04/2022] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND MRI guidance of arterial endovascular interventions could be beneficial as it does not require radiation exposure, allows intrinsic blood-tissue contrast, and enables three-dimensional and functional imaging, however, clinical applications are still limited. PURPOSE To review the current state of MRI-guided arterial endovascular interventions and to identify the most commonly reported challenges. STUDY TYPE Systematic review. POPULATION Pubmed, Embase, Web of Science, and The Cochrane Library were systematically searched to find relevant articles. The search strategy combined synonyms for vascular pathology, endovascular therapy, and real-time MRI guidance. FIELD STRENGTH/SEQUENCE No field strength or sequence restrictions were applied. ASSESSMENT Two reviewers independently identified and reviewed the original articles and extracted relevant data. STATISTICAL TESTS Results of the included original articles are reported. RESULTS A total of 24,809 studies were identified for screening. Eighty-eight studies were assessed for eligibility, after which data were extracted from 43 articles (6 phantom, 33 animal, and 4 human studies). Reported technical success rates for animal and human studies ranged between 42% to 100%, and the average complication rate was 5.8% (animal studies) and 8.8% (human studies). Main identified challenges were related to spatial and temporal resolution as well as safety, design, and scarcity of current MRI-compatible endovascular devices. DATA CONCLUSION MRI guidance of endovascular arterial interventions seems feasible, however, included articles included mostly small single-center case series. Several hurdles remain to be overcome before larger trials can be undertaken. Main areas of research should focus on adequate imaging protocols with integrated tracking of dedicated endovascular devices.
Collapse
Affiliation(s)
- Han Nijsink
- Department of Medical ImagingRadboudumcNijmegenNetherlands
| | | | | | | | | |
Collapse
|
4
|
Kilbride BF, Narsinh KH, Jordan CD, Mueller K, Moore T, Martin AJ, Wilson MW, Hetts SW. MRI-guided endovascular intervention: current methods and future potential. Expert Rev Med Devices 2022; 19:763-778. [PMID: 36373162 PMCID: PMC9869980 DOI: 10.1080/17434440.2022.2141110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 10/25/2022] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Image-guided endovascular interventions, performed using the insertion and navigation of catheters through the vasculature, have been increasing in number over the years, as minimally invasive procedures continue to replace invasive surgical procedures. Such endovascular interventions are almost exclusively performed under x-ray fluoroscopy, which has the best spatial and temporal resolution of all clinical imaging modalities. Magnetic resonance imaging (MRI) offers unique advantages and could be an attractive alternative to conventional x-ray guidance, but also brings with it distinctive challenges. AREAS COVERED In this review, the benefits and limitations of MRI-guided endovascular interventions are addressed, systems and devices for guiding such interventions are summarized, and clinical applications are discussed. EXPERT OPINION MRI-guided endovascular interventions are still relatively new to the interventional radiology field, since significant technical hurdles remain to justify significant costs and demonstrate safety, design, and robustness. Clinical applications of MRI-guided interventions are promising but their full potential may not be realized until proper tools designed to function in the MRI environment are available. Translational research and further preclinical studies are needed before MRI-guided interventions will be practical in a clinical interventional setting.
Collapse
Affiliation(s)
- Bridget F. Kilbride
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Kazim H. Narsinh
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | | | | | - Teri Moore
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Alastair J. Martin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Mark W. Wilson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Steven W. Hetts
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
5
|
Nijsink H, Overduin CG, Brand P, De Jong SF, Borm PJA, Warlé MC, Fütterer JJ. Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study. Eur Radiol Exp 2022; 6:11. [PMID: 35199259 PMCID: PMC8866618 DOI: 10.1186/s41747-022-00262-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 01/04/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Passive paramagnetic markers on magnetic resonance imaging (MRI)-compatible endovascular devices induce susceptibility artifacts, enabling MRI-visibility and real-time MRI-guidance. Optimised visibility is crucial for automatic detection and device tracking but depends on MRI technical parameters and marker characteristics. We assessed marker visibility and automatic detection robustness for varying MRI parameters and marker characteristics in a pulsatile flow phantom. METHODS Guidewires with varying iron(II,III) oxide nanoparticle (IONP) concentration markers were imaged using gradient-echo (GRE) and balanced steady-state free precession (bSSFP) sequences at 3 T. Furthermore, echo time (TE), slice thickness (ST) and phase encoding direction (PED) were varied. Artifact width was measured and contrast-to-noise ratios were calculated. Marker visibility and image quality were scored by two MRI interventional radiologists. Additionally, a deep learning model for automatic marker detection was trained and the effects of the parameters on detection performance were evaluated. Two-tailed Wilcoxon signed-rank tests were used (significance level, p < 0.05). RESULTS Medan artifact width (IQR) was larger in bSSFP compared to GRE images (12.7 mm (11.0-15.2) versus 8.4 mm (6.5-11.0)) (p < 0.001) and showed a positive relation with TE and IONP concentration. Switching PED and doubling ST had limited effect on artifact width. Image quality assessment scores were higher for GRE compared to bSSFP images. The deep learning model automatically detected the markers. However, the model performance was reduced after adjusting PED, TE, and IONP concentration. CONCLUSION Marker visibility was sufficient and a large range of artifact sizes was generated by adjusting TE and IONP concentration. Deep learning-based marker detection was feasible but performance decreased for altered MR parameters. These factors should be considered to optimise device visibility and ensure reliable automatic marker detectability in MRI-guided endovascular interventions.
Collapse
Affiliation(s)
- Han Nijsink
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands.
| | - Christiaan G Overduin
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands
| | - Patrick Brand
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands
| | - Sytse F De Jong
- Department of Cardiothoracic Surgery, Radboudumc, Nijmegen, The Netherlands
| | | | - Michiel C Warlé
- Department of Vascular and Transplant Surgery, Radboudumc, Nijmegen, The Netherlands
| | - Jurgen J Fütterer
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands
| |
Collapse
|
6
|
Meierhofer C, Belker K, Shehu N, Latus H, Mkrtchyan N, Naumann S, Martinoff S, Stern H, Eicken A, Ewert P. Real-time CMR guidance for intracardiac and great vessel pressure mapping in patients with congenital heart disease using an MR conditional guidewire-results of 25 patients. Cardiovasc Diagn Ther 2021; 11:1356-1366. [PMID: 35070804 PMCID: PMC8748488 DOI: 10.21037/cdt-20-575] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 10/27/2020] [Indexed: 02/06/2024]
Abstract
BACKGROUND The aim of this study was to test a CE-certified MR-conditional guidewire to facilitate blood pressure measurement in cardiovascular magnetic resonance (CMR) using fluid-filled catheters in patients with congenital heart disease (CHD). The main purpose was to determine procedural success in a post market clinical follow-up (PMCF) for routine procedure in a diagnostic and interventional workflow. Real-time CMR provides high quality imaging without the risk of exposing the patient to X-rays, especially for patients with irregular heart anatomy and patients who are susceptible to radiation and iodinated contrast media. To date, the assessment of blood pressure gradients is not a common feature of CMR, as these gradients cannot be accurately evaluated in routine CMR. METHODS Twenty-five CHD patients who were planned for combined clinical CMR and diagnostic and/or interventional catheterization were enrolled in the trial. Prior to inclusion, a specific procedure for catheterization in CMR was defined, encompassing the assessment of pressure and pressure gradients in the heart and great vessels. RESULTS By the use of an MR-conditional guidewire we successfully measured specific pressure and pressure gradients in up to 92% of cases with liquid-filled catheters which were guided exclusively under CMR guidance. There were no guidewire-related adverse events, and guidewire guidance and manipulation of catheters were successful. CONCLUSIONS Using a MR-conditional guidewire assists in easily reaching targets in the heart and great vessels and makes the catheter itself visible, so that invasive blood pressure assessment by CMR guidance with liquid-filled catheters can be improved. KEYWORDS Cardiovascular magnetic resonance (CMR); congenital heart disease (CHD); cardiac catheterization; magnetic resonance; pressure; guidewire.
Collapse
Affiliation(s)
- Christian Meierhofer
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Kristina Belker
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Nerejda Shehu
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Heiner Latus
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Naira Mkrtchyan
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Susanne Naumann
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Stefan Martinoff
- Radiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Heiko Stern
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Andreas Eicken
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
| | - Peter Ewert
- Congenital Heart Disease and Pediatric Cardiology, German Heart Center Munich, Technical University of Munich, Munich, Germany
- Munich Heart Alliance, Deutsches Zentrum für Herz-Kreislauf-Forschung e.V., Berlin, Germany
| |
Collapse
|
7
|
Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres. Cancers (Basel) 2021; 13:cancers13215462. [PMID: 34771626 PMCID: PMC8582586 DOI: 10.3390/cancers13215462] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 10/27/2021] [Accepted: 10/28/2021] [Indexed: 11/30/2022] Open
Abstract
Simple Summary Selective internal radiation therapy (SIRT) is a treatment for patients with liver cancer that involves the injection of radioactive microspheres into the liver artery. For a successful treatment, it is important that tumours are adequately covered with these microspheres; however, there is currently no method to assess this intraoperatively. As holmium microspheres are paramagnetic, MRI can be used to visualize the holmium deposition directly after administration, and possibly to adapt the treatment if necessary. In order to exploit this advantage and provide a personally optimized approach to SIRT, the administration could ideally be performed within a clinical MRI scanner. It is, however, unclear whether all materials (catheters, administration device) used during the procedure are safe for use in the MRI suite. Additionally, we explore the capability of MRI to visualize the microspheres in near real-time during injection, which would be a requirement for successful MRI-guided treatment. We further illustrate our findings with an initial patient case. Abstract Selective internal radiation therapy (SIRT) is a treatment modality for liver tumours during which radioactive microspheres are injected into the hepatic arterial tree. Holmium-166 (166Ho) microspheres used for SIRT can be visualized and quantified with MRI, potentially allowing for MRI guidance during SIRT. The purpose of this study was to investigate the MRI compatibility of two angiography catheters and a microcatheter typically used for SIRT, and to explore the detectability of 166Ho microspheres in a flow phantom using near real-time MRI. MR safety tests were performed at a 3 T MRI system according to American Society for Testing of Materials standard test methods. To assess the near real-time detectability of 166Ho microspheres, a flow phantom was placed in the MRI bore and perfused using a peristaltic pump, simulating the flow in the hepatic artery. Dynamic MR imaging was performed using a 2D FLASH sequence during injection of different concentrations of 166Ho microspheres. In the safety assessment, no significant heating (ΔTmax 0.7 °C) was found in any catheter, and no magnetic interaction was found in two out of three of the used catheters. Near real-time MRI visualization of 166Ho microsphere administration was feasible and depended on holmium concentration and vascular flow speed. Finally, we demonstrate preliminary imaging examples on the in vivo catheter visibility and near real-time imaging during 166Ho microsphere administration in an initial patient case treated with SIRT in a clinical 3 T MRI. These results support additional research to establish the feasibility and safety of this procedure in vivo and enable the further development of a personalized MRI-guided approach to SIRT.
Collapse
|
8
|
Yildirim DK, Bruce C, Uzun D, Rogers T, O'Brien K, Ramasawmy R, Campbell-Washburn A, Herzka DA, Lederman RJ, Kocaturk O. A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T. Magn Reson Med 2021; 86:1786-1801. [PMID: 33860962 DOI: 10.1002/mrm.28804] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 03/05/2021] [Accepted: 03/23/2021] [Indexed: 01/14/2023]
Abstract
PURPOSE This work aims to fabricate RF antenna components on metallic needle surfaces using biocompatible polyester tubing and conductive ink to develop an active interventional MRI needle for clinical use at 0.55 Tesla. METHODS A custom computer numeric control-based conductive ink printing method was developed. Based on electromagnetic simulation results, thin-film RF antennas were printed with conductive ink and used to fabricate a medical grade, 20-gauge (0.87 mm outer diameter), 90-mm long active interventional MRI needle. The MRI visibility performance of the active needle prototype was tested in vitro in 1 gel phantom and in vivo in 1 swine. A nearly identical active needle constructed using a 44 American Wire Gauge insulated copper wire-wound RF receiver antenna was a comparator. The RF-induced heating risk was evaluated in a gel phantom per American Society for Testing and Materials (ASTM) 2182-19. RESULTS The active needle prototype with printed RF antenna was clearly visible both in vitro and in vivo under MRI. The maximum RF-induced temperature rise of prototypes with printed RF antenna and insulated copper wire antenna after a 3.96 W/kg, 15 min. long scan were 1.64°C and 8.21°C, respectively. The increase in needle diameter was 98 µm and 264 µm for prototypes with printed RF antenna and copper wire-wound antenna, respectively. CONCLUSION The active needle prototype with conductive ink printed antenna provides distinct device visibility under MRI. Variations on the needle surface are mitigated compared to use of a 44 American Wire Gauge copper wire. RF-induced heating tests support device RF safety under MRI. The proposed method enables fabrication of small diameter active interventional MRI devices having complex geometries, something previously difficult using conventional methods.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christopher Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Dogangun Uzun
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
9
|
Abstract
Interventional neuro-oncology encompasses an array of image-guided therapies-intra-arterial chemotherapy, regional drug delivery, chemoembolization, tumor ablation-along with techniques to improve therapy delivery such as physical or chemical blood-brain barrier disruption and percutaneous catheter placement. Endovascular and percutaneous image-guided approaches to the treatment of the brain, eye, and other head and neck tumors will be discussed.
Collapse
Affiliation(s)
- Monica S Pearl
- Division of Interventional Neuroradiology, Johns Hopkins Hospital, Baltimore, MD, United States; Department of Radiology, Children's National Medical Center, Washington, DC, United States.
| | - Nalin Gupta
- Division of Pediatric Neurosurgery, University of California San Francisco Benioff Children's Hospital, San Francisco, CA, United States
| | - Steven W Hetts
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, United States
| |
Collapse
|