1
|
Javed A, Ramasawmy R, Ozenne V, Su P, Chow K, Campbell-Washburn A. Increasing the scan-efficiency of pulmonary imaging at 0.55 T using iterative concomitant field and motion-corrected reconstruction. Magn Reson Med 2024; 92:173-185. [PMID: 38501940 PMCID: PMC11055666 DOI: 10.1002/mrm.30054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 01/03/2024] [Accepted: 02/01/2024] [Indexed: 03/20/2024]
Abstract
PURPOSE To develop an iterative concomitant field and motion corrected (iCoMoCo) reconstruction for isotropic high-resolution UTE pulmonary imaging at 0.55 T. METHODS A free-breathing golden-angle stack-of-spirals UTE sequence was used to acquire data for 8 min with prototype and commercial 0.55 T MRI scanners. The data was binned into 12 respiratory phases based on superior-inferior navigator readouts. The previously published iterative motion corrected (iMoCo) reconstruction was extended to include concomitant field correction directly in the cost function. The reconstruction was implemented within the Gadgetron framework for inline reconstruction. Data were retrospectively reconstructed to simulate scan times of 2, 4, 6, and 8 min. Image quality was assessed using apparent SNR and image sharpness. The technique was evaluated in healthy volunteers and patients with known lung pathology including coronavirus disease 2019 infection, chronic granulomatous disease, lymphangioleiomyomatosis, and lung nodules. RESULTS The technique provided diagnostic-quality images, and image quality was maintained with a slight loss in SNR for simulated scan times down to 4 min. Parenchymal apparent SNR was 4.33 ± 0.57, 5.96 ± 0.65, 7.36 ± 0.64, and 7.87 ± 0.65 using iCoMoCo with scan times of 2, 4, 6, and 8 min, respectively. Image sharpness at the diaphragm was comparable between iCoMoCo and reference images. Concomitant field corrections visibly improved the sharpness of anatomical structures away from the isocenter. Inline image reconstruction and artifact correction were achieved in <5 min. CONCLUSION The proposed iCoMoCo pulmonary imaging technique can generate diagnostic quality images with 1.75 mm isotropic resolution in less than 5 min using a 6-min acquisition, on a 0.55 T scanner.
Collapse
Affiliation(s)
- Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Valéry Ozenne
- Univ. Bordeaux, CNRS, Centre de Résonance Magnétique des Systèmes Biologiques, UMR 5536, F-33000 Bordeaux, France
| | - Pan Su
- Siemens Medical Solutions USA Inc., 40 Liberty Boulevard, Malvern PA, 1935 USA
| | - Kelvin Chow
- Siemens Medical Solutions USA Inc., 40 Liberty Boulevard, Malvern PA, 1935 USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| |
Collapse
|
2
|
Uzun D, Yildirim DK, Bruce CG, Halaby RN, Jaimes A, Potersnak A, Ramasawmy R, Campbell-Washburn A, Lederman RJ, Kocaturk O. Interventional device tracking under MRI via alternating current controlled inhomogeneities. Magn Reson Med 2024; 92:346-360. [PMID: 38394163 PMCID: PMC11055668 DOI: 10.1002/mrm.30031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/10/2024] [Accepted: 01/12/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.
Collapse
Affiliation(s)
- Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rim N. Halaby
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Andi Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
3
|
Daudé P, Ramasawmy R, Javed A, Lederman RJ, Chow K, Campbell-Washburn AE. Inline automatic quality control of 2D phase-contrast flow MRI for subject-specific scan time adaptation. Magn Reson Med 2024. [PMID: 38469944 DOI: 10.1002/mrm.30083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/01/2024] [Accepted: 02/24/2024] [Indexed: 03/13/2024]
Abstract
PURPOSE To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR. METHODS We designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline. RESULTS SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s ± 67 s (aorta) and 3 min ± 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery). CONCLUSION The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.
Collapse
Affiliation(s)
- Pierre Daudé
- Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ahsan Javed
- Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Laboratory of Cardiovascular Intervention, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kelvin Chow
- Siemens Healthcare Ltd., Calgary, Alberta, Canada
| | - Adrienne E Campbell-Washburn
- Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research, National Heart Lung & Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
4
|
Campbell-Washburn AE, Varghese J, Nayak KS, Ramasawmy R, Simonetti OP. Cardiac MRI at Low Field Strengths. J Magn Reson Imaging 2024; 59:412-430. [PMID: 37530545 PMCID: PMC10834858 DOI: 10.1002/jmri.28890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 08/03/2023] Open
Abstract
Cardiac MR imaging is well established for assessment of cardiovascular structure and function, myocardial scar, quantitative flow, parametric mapping, and myocardial perfusion. Despite the clear evidence supporting the use of cardiac MRI for a wide range of indications, it is underutilized clinically. Recent developments in low-field MRI technology, including modern data acquisition and image reconstruction methods, are enabling high-quality low-field imaging that may improve the cost-benefit ratio for cardiac MRI. Studies to-date confirm that low-field MRI offers high measurement concordance and consistent interpretation with clinical imaging for several routine sequences. Moreover, low-field MRI may enable specific new clinical opportunities for cardiac imaging such as imaging near metal implants, MRI-guided interventions, combined cardiopulmonary assessment, and imaging of patients with severe obesity. In this review, we discuss the recent progress in low-field cardiac MRI with a focus on technical developments and early clinical validation studies. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Adrienne E Campbell-Washburn
- Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD USA
| | - Juliet Varghese
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
- Alfred Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD USA
| | - Orlando P Simonetti
- Division of Cardiovascular Medicine, Department of Internal Medicine, College of Medicine, The Ohio State University, Columbus, OH, USA
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
5
|
Seemann F, Heiberg E, Bruce CG, Khan JM, Potersnak A, Ramasawmy R, Carlsson M, Arheden H, Lederman RJ, Campbell-Washburn AE. Non-invasive pressure-volume loops using the elastance model and CMR: a porcine validation at transient pre-loads. Eur Heart J Imaging Methods Pract 2024; 2:qyae016. [PMID: 38645798 PMCID: PMC11026081 DOI: 10.1093/ehjimp/qyae016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 02/28/2024] [Indexed: 04/23/2024]
Abstract
Aims Pressure-volume (PV) loops have utility in the evaluation of cardiac pathophysiology but require invasive measurements. Recently, a time-varying elastance model to derive PV loops non-invasively was proposed, using left ventricular (LV) volume by cardiovascular magnetic resonance (CMR) and brachial cuff pressure as inputs. Validation was performed using CMR and pressure measurements acquired on the same day, but not simultaneously, and without varying pre-loads. This study validates the non-invasive elastance model used to estimate PV loops at varying pre-loads, compared with simultaneous measurements of invasive pressure and volume from real-time CMR, acquired concurrent to an inferior vena cava (IVC) occlusion. Methods and results We performed dynamic PV loop experiments under CMR guidance in 15 pigs (n = 7 naïve, n = 8 with ischaemic cardiomyopathy). Pre-load was altered by IVC occlusion, while simultaneously acquiring invasive LV pressures and volumes from real-time CMR. Pairing pressure and volume signals yielded invasive PV loops, and model-based PV loops were derived using real-time LV volumes. Haemodynamic parameters derived from invasive and model-based PV loops were compared. Across 15 pigs, 297 PV loops were recorded. Intra-class correlation coefficient (ICC) agreement was excellent between model-based and invasive parameters: stroke work (bias = 0.007 ± 0.03 J, ICC = 0.98), potential energy (bias = 0.02 ± 0.03 J, ICC = 0.99), ventricular energy efficiency (bias = -0.7 ± 2.7%, ICC = 0.98), contractility (bias = 0.04 ± 0.1 mmHg/mL, ICC = 0.97), and ventriculoarterial coupling (bias = 0.07 ± 0.15, ICC = 0.99). All haemodynamic parameters differed between naïve and cardiomyopathy animals (P < 0.05). The invasive vs. model-based PV loop dice similarity coefficient was 0.88 ± 0.04. Conclusion An elastance model-based estimation of PV loops and associated haemodynamic parameters provided accurate measurements at transient loading conditions compared with invasive PV loops.
Collapse
Affiliation(s)
- Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Einar Heiberg
- Department of Clinical Sciences Lund, Clinical Physiology, Skane University Hospital, Lund University, Entrégatan 7, 221 85 Lund, Sweden
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Jaffar M Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Marcus Carlsson
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Håkan Arheden
- Department of Clinical Sciences Lund, Clinical Physiology, Skane University Hospital, Lund University, Entrégatan 7, 221 85 Lund, Sweden
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D219, Bethesda, MD 20892, USA
| |
Collapse
|
6
|
Seemann F, Javed A, Khan JM, Bruce CG, Chae R, Yildirim DK, Potersnak A, Wang H, Baute S, Ramasawmy R, Lederman RJ, Campbell-Washburn AE. Dynamic lung water MRI during exercise stress. Magn Reson Med 2023; 90:1396-1413. [PMID: 37288601 PMCID: PMC10521349 DOI: 10.1002/mrm.29716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 04/06/2023] [Accepted: 05/09/2023] [Indexed: 06/09/2023]
Abstract
PURPOSE Exercise-induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time-resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress. METHODS The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time-resolved images were acquired at 0.55T using a continuous 3D stack-of-spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding-window reconstruction with 90-s temporal resolution in 20-s increments. A supine MRI-compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified. RESULTS A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (-1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%). CONCLUSION Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding-window image reconstruction.
Collapse
Affiliation(s)
- Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Jaffar M Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rachel Chae
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Haiyan Wang
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Scott Baute
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
7
|
Wieslander B, Seemann F, Javed A, Bruce CG, Ramasawmy R, Jaimes A, Lucas K, Frasier V, O'Brien KJ, Potersnak A, Khan JM, Schenke WH, Chen MY, Lederman RJ, Campbell-Washburn AE. Impact of Vasodilation on Oxygen-Enhanced Functional Lung MRI at 0.55 T. Invest Radiol 2023; 58:663-672. [PMID: 36822664 PMCID: PMC10947575 DOI: 10.1097/rli.0000000000000958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
BACKGROUND Oxygen-enhanced magnetic resonance imaging (OE-MRI) can be used to assess regional lung function without ionizing radiation. Inhaled oxygen acts as a T1-shortening contrast agent to increase signal in T1-weighted (T1w) images. However, increase in proton density from pulmonary hyperoxic vasodilation may also contribute to the measured signal enhancement. Our aim was to quantify the relative contributions of the T1-shortening and vasodilatory effects of oxygen to signal enhancement in OE-MRI in both swine and healthy volunteers. METHODS We imaged 14 anesthetized female swine (47 ± 8 kg) using a prototype 0.55 T high-performance MRI system while experimentally manipulating oxygenation and blood volume independently through oxygen titration, partial occlusion of the vena cava for volume reduction, and infusion of colloid fluid (6% hydroxyethyl starch) for volume increase. Ten healthy volunteers were imaged before, during, and after hyperoxia. Two proton density-weighted (PDw) and 2 T1w ultrashort echo time images were acquired per experimental state. The median PDw and T1w percent signal enhancement (PSE), compared with baseline room air, was calculated after image registration and correction for lung volume changes. Differences in median PSE were compared using Wilcoxon signed rank test. RESULTS The PSE in PDw images after 100% oxygen was similar in swine (1.66% ± 1.41%, P = 0.01) and in healthy volunteers (1.99% ± 1.79%, P = 0.02), indicating that oxygen-induced pulmonary vasodilation causes ~2% lung proton density increase. The PSE in T1w images after 100% oxygen was also similar (swine, 9.20% ± 1.68%, P < 0.001; healthy volunteers, 10.10% ± 3.05%, P < 0.001). The PSE in T1w enhancement was oxygen dose-dependent in anesthetized swine, and we measured a dose-dependent PDw image signal increase from infused fluids. CONCLUSIONS The contribution of oxygen-induced vasodilation to T1w OE-MRI signal was measurable using PDw imaging and was found to be ~2% in both anesthetized swine and in healthy volunteers. This finding may have implications for patients with regional or global hypoxia or vascular dysfunction undergoing OE-MRI and suggest that PDw imaging may be useful to account for oxygen-induced vasodilation in OE-MRI.
Collapse
Affiliation(s)
| | - Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Andrea Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Katherine Lucas
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Victoria Frasier
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Kendall J O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Jaffar M Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - William H Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Marcus Y Chen
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD
| |
Collapse
|
8
|
Rogers T, Campbell-Washburn AE, Ramasawmy R, Yildirim DK, Bruce CG, Grant LP, Stine AM, Kolandaivelu A, Herzka DA, Ratnayaka K, Lederman RJ. Interventional cardiovascular magnetic resonance: state-of-the-art. J Cardiovasc Magn Reson 2023; 25:48. [PMID: 37574552 PMCID: PMC10424337 DOI: 10.1186/s12968-023-00956-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Accepted: 07/25/2023] [Indexed: 08/15/2023] Open
Abstract
Transcatheter cardiovascular interventions increasingly rely on advanced imaging. X-ray fluoroscopy provides excellent visualization of catheters and devices, but poor visualization of anatomy. In contrast, magnetic resonance imaging (MRI) provides excellent visualization of anatomy and can generate real-time imaging with frame rates similar to X-ray fluoroscopy. Realization of MRI as a primary imaging modality for cardiovascular interventions has been slow, largely because existing guidewires, catheters and other devices create imaging artifacts and can heat dangerously. Nonetheless, numerous clinical centers have started interventional cardiovascular magnetic resonance (iCMR) programs for invasive hemodynamic studies or electrophysiology procedures to leverage the clear advantages of MRI tissue characterization, to quantify cardiac chamber function and flow, and to avoid ionizing radiation exposure. Clinical implementation of more complex cardiovascular interventions has been challenging because catheters and other tools require re-engineering for safety and conspicuity in the iCMR environment. However, recent innovations in scanner and interventional device technology, in particular availability of high performance low-field MRI scanners could be the inflection point, enabling a new generation of iCMR procedures. In this review we review these technical considerations, summarize contemporary clinical iCMR experience, and consider potential future applications.
Collapse
Affiliation(s)
- Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA.
- Section of Interventional Cardiology, MedStar Washington Hospital Center, 110 Irving St NW, Suite 4B01, Washington, DC, 20011, USA.
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - D Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - Laurie P Grant
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - Annette M Stine
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - Aravindan Kolandaivelu
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
- Johns Hopkins Hospital, Baltimore, MD, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
| | - Kanishka Ratnayaka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA
- Rady Children's Hospital, San Diego, CA, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10/Room 2C713, 9000 Rockville Pike, Bethesda, MD, 20892-1538, USA.
| |
Collapse
|
9
|
Wang Z, Ramasawmy R, Feng X, Campbell-Washburn AE, Mugler JP, Meyer CH. Concomitant magnetic-field compensation for 2D spiral-ring turbo spin-echo imaging at 0.55T and 1.5T. Magn Reson Med 2023; 90:552-568. [PMID: 37036033 PMCID: PMC10578525 DOI: 10.1002/mrm.29663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/08/2023] [Accepted: 03/21/2023] [Indexed: 04/11/2023]
Abstract
PURPOSE To develop 2D turbo spin-echo (TSE) imaging using annular spiral rings (abbreviated "SPRING-RIO TSE") with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2 -weighted imaging. METHODS Strategies of gradient waveform modifications were implemented in SPRING-RIO TSE for compensation of self-squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction-based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time-varying and spatially dependent concomitant fields was simulated, and echo-to-echo phase variations before and after sequence-based compensation were compared. Images from SPRING-RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions. RESULTS Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off-resonance corrections. Volunteer data showed that after full correction, the SPRING-RIO TSE sequence achieved high image quality with improved SNR efficiency (15%-20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low-field (0.55T). CONCLUSION Implementation of SPRING-RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time-varying along the echo train and temporally asymmetric in TSE-based imaging.
Collapse
Affiliation(s)
- Zhixing Wang
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Xue Feng
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
| | - Adrienne E. Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - John P. Mugler
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
- Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Craig H. Meyer
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
- Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| |
Collapse
|
10
|
Ramasawmy R, Mugler JP, Javed A, Wang Z, Herzka DA, Meyer CH, Campbell-Washburn AE. Concomitant field compensation of spiral turbo spin-echo at 0.55 T. MAGMA 2023; 36:465-475. [PMID: 37306784 PMCID: PMC10771127 DOI: 10.1007/s10334-023-01103-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 04/26/2023] [Accepted: 05/15/2023] [Indexed: 06/13/2023]
Abstract
OBJECTIVE Diagnostic-quality neuroimaging methods are vital for widespread clinical adoption of low field MRI. Spiral imaging is an efficient acquisition method that can mitigate the reduced signal-to-noise ratio at lower field strengths. As concomitant field artifacts are worse at lower field, we propose a generalizable quadratic gradient-field nulling as an echo-to-echo compensation and apply it to spiral TSE at 0.55 T. MATERIALS AND METHODS A spiral in-out TSE acquisition was developed with a compensation for concomitant field variation between spiral interleaves, by adding bipolar gradients around each readout to minimize phase differences at each refocusing pulse. Simulations were performed to characterize concomitant field compensation approaches. We demonstrate our proposed compensation method in phantoms and (n = 8) healthy volunteers at 0.55 T. RESULTS Spiral read-outs with integrated spoiling demonstrated strong concomitant field artifacts but were mitigated using the echo-to-echo compensation. Simulations predicted a decrease of concomitant field phase RMSE between echoes of 42% using the proposed compensation. Spiral TSE improved SNR by 17.2 ± 2.3% compared to reference Cartesian acquisition. DISCUSSION We demonstrated a generalizable approach to mitigate concomitant field artifacts for spiral TSE acquisitions via the addition of quadratic-nulling gradients, which can potentially improve neuroimaging at low-field through increased acquisition efficiency.
Collapse
Affiliation(s)
- Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA.
| | - John P Mugler
- Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, VA, USA
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Zhixing Wang
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Craig H Meyer
- Department of Radiology & Medical Imaging, University of Virginia, Charlottesville, VA, USA
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
11
|
Yildirim DK, Uzun D, Bruce CG, Khan JM, Rogers T, Schenke WH, Ramasawmy R, Campbell-Washburn A, Herzka D, Lederman RJ, Kocaturk O. An interventional MRI guidewire combining profile and tip conspicuity for catheterization at 0.55T. Magn Reson Med 2023; 89:845-858. [PMID: 36198118 PMCID: PMC9712240 DOI: 10.1002/mrm.29466] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 08/04/2022] [Accepted: 09/02/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Daniel Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
12
|
Seemann F, Bruce CG, Khan JM, Ramasawmy R, Potersnak AG, Herzka DA, Kakareka JW, Jaimes AE, Schenke WH, O'Brien KJ, Lederman RJ, Campbell-Washburn AE. Dynamic pressure-volume loop analysis by simultaneous real-time cardiovascular magnetic resonance and left heart catheterization. J Cardiovasc Magn Reson 2023; 25:1. [PMID: 36642713 PMCID: PMC9841727 DOI: 10.1186/s12968-023-00913-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 01/05/2023] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND Left ventricular (LV) contractility and compliance are derived from pressure-volume (PV) loops during dynamic preload reduction, but reliable simultaneous measurements of pressure and volume are challenging with current technologies. We have developed a method to quantify contractility and compliance from PV loops during a dynamic preload reduction using simultaneous measurements of volume from real-time cardiovascular magnetic resonance (CMR) and invasive LV pressures with CMR-specific signal conditioning. METHODS Dynamic PV loops were derived in 16 swine (n = 7 naïve, n = 6 with aortic banding to increase afterload, n = 3 with ischemic cardiomyopathy) while occluding the inferior vena cava (IVC). Occlusion was performed simultaneously with the acquisition of dynamic LV volume from long-axis real-time CMR at 0.55 T, and recordings of invasive LV and aortic pressures, electrocardiogram, and CMR gradient waveforms. PV loops were derived by synchronizing pressure and volume measurements. Linear regression of end-systolic- and end-diastolic- pressure-volume relationships enabled calculation of contractility. PV loops measurements in the CMR environment were compared to conductance PV loop catheter measurements in 5 animals. Long-axis 2D LV volumes were validated with short-axis-stack images. RESULTS Simultaneous PV acquisition during IVC-occlusion was feasible. The cardiomyopathy model measured lower contractility (0.2 ± 0.1 mmHg/ml vs 0.6 ± 0.2 mmHg/ml) and increased compliance (12.0 ± 2.1 ml/mmHg vs 4.9 ± 1.1 ml/mmHg) compared to naïve animals. The pressure gradient across the aortic band was not clinically significant (10 ± 6 mmHg). Correspondingly, no differences were found between the naïve and banded pigs. Long-axis and short-axis LV volumes agreed well (difference 8.2 ± 14.5 ml at end-diastole, -2.8 ± 6.5 ml at end-systole). Agreement in contractility and compliance derived from conductance PV loop catheters and in the CMR environment was modest (intraclass correlation coefficient 0.56 and 0.44, respectively). CONCLUSIONS Dynamic PV loops during a real-time CMR-guided preload reduction can be used to derive quantitative metrics of contractility and compliance, and provided more reliable volumetric measurements than conductance PV loop catheters.
Collapse
Affiliation(s)
- Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA.
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Jaffar M Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Amanda G Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - John W Kakareka
- Instrumentation Development and Engineering Application Solutions, Division of Intramural Research, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Andrea E Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - William H Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Kendall J O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood, Institute, National Institutes of Health, 10 Center Drive, Building 10 Rm B1D47, Bethesda, MD, 20892, USA
| |
Collapse
|
13
|
Freitas EJS, Gbadamassi AG, Ramasawmy R, Gonçalves MS, Neto JPM. INFLUENCE OF IL-6 VARIANTS TO BLOOD-TRANSFUSION NUMBERS IN HEART DISEASES. Hematol Transfus Cell Ther 2022. [DOI: 10.1016/j.htct.2022.09.1109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
14
|
Javed A, Ramasawmy R, O'Brien K, Mancini C, Su P, Majeed W, Benkert T, Bhat H, Suffredini AF, Malayeri A, Campbell-Washburn AE. Erratum to: Self-gated 3D stack-of-spirals UTE pulmonary imaging at 0.55 T (Magn Reson Med 2022;87:1784-1798). Magn Reson Med 2022; 88:2326-2327. [PMID: 35924665 DOI: 10.1002/mrm.29392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 11/07/2022]
Affiliation(s)
- Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christine Mancini
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Pan Su
- Siemens Medical Solutions USA Inc, Malvern, Pennsylvania, USA
| | - Waqas Majeed
- Siemens Medical Solutions USA Inc, Malvern, Pennsylvania, USA
| | | | - Himanshu Bhat
- Siemens Medical Solutions USA Inc, Malvern, Pennsylvania, USA
| | - Anthony F Suffredini
- Critical Care Medicine Department, Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | - Ashkan Malayeri
- Department of Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Department of Health and Human Services, Bethesda, Maryland, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
15
|
Seemann F, Javed A, Chae R, Ramasawmy R, O'Brien K, Baute S, Xue H, Lederman RJ, Campbell-Washburn AE. Imaging gravity-induced lung water redistribution with automated inline processing at 0.55 T cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2022; 24:35. [PMID: 35668497 PMCID: PMC9172183 DOI: 10.1186/s12968-022-00862-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 04/05/2022] [Indexed: 01/18/2024] Open
Abstract
BACKGROUND Quantitative assessment of dynamic lung water accumulation is of interest to unmask latent heart failure. We develop and validate a free-breathing 3D ultrashort echo time (UTE) sequence with automated inline image processing to image changes in lung water density (LWD) using high-performance 0.55 T cardiovascular magnetic resonance (CMR). METHODS Quantitative lung water CMR was performed on 15 healthy subjects using free-breathing 3D stack-of-spirals proton density weighted UTE at 0.55 T. Inline image reconstruction and automated image processing was performed using the Gadgetron framework. A gravity-induced redistribution of LWD was provoked by sequentially acquiring images in the supine, prone, and again supine position. Quantitative validation was performed in a phantom array of vials containing mixtures of water and deuterium oxide. RESULTS The phantom experiment validated the capability of the sequence in quantifying water density (bias ± SD 4.3 ± 4.8%, intraclass correlation coefficient, ICC = 0.97). The average global LWD was comparable between imaging positions (supine 24.7 ± 3.4%, prone 22.7 ± 3.1%, second supine 25.3 ± 3.6%), with small differences between imaging phases (first supine vs prone 2.0%, p < 0.001; first supine vs second supine - 0.6%, p = 0.001; prone vs second supine - 2.7%, p < 0.001). In vivo test-retest repeatability in LWD was excellent (- 0.17 ± 0.91%, ICC = 0.97). A regional LWD redistribution was observed in all subjects when repositioning, with a predominant posterior LWD accumulation when supine, and anterior accumulation when prone (difference in anterior-posterior LWD: supine - 11.6 ± 2.7%, prone 5.5 ± 2.7%, second supine - 11.4 ± 2.9%). Global LWD maps were calculated inline within 23.2 ± 0.3 s following the image reconstruction using the automated pipeline. CONCLUSIONS Redistribution of LWD due to gravitational forces can be depicted and quantified using a validated free-breathing 3D proton density weighted UTE sequence and inline automated image processing pipeline on a high-performance 0.55 T CMR system.
Collapse
Affiliation(s)
- Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Rachel Chae
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Scott Baute
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Hui Xue
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
| |
Collapse
|
16
|
Khan JM, Bruce CG, Greenbaum AB, Babaliaros VC, Jaimes AE, Schenke WH, Ramasawmy R, Seemann F, Herzka DA, Rogers T, Eckhaus MA, Campbell-Washburn A, Guyton RA, Lederman RJ. Transcatheter Myotomy to Relieve Left Ventricular Outflow Tract Obstruction: The Septal Scoring Along the Midline Endocardium Procedure in Animals. Circ Cardiovasc Interv 2022; 15:e011686. [PMID: 35378990 DOI: 10.1161/circinterventions.121.011686] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Left ventricular outflow tract obstruction complicates hypertrophic cardiomyopathy and transcatheter mitral valve replacement. Septal reduction therapies including surgical myectomy and alcohol septal ablation are limited by surgical morbidity or coronary anatomy and high pacemaker rates, respectively. We developed a novel transcatheter procedure, mimicking surgical myotomy, called Septal Scoring Along the Midline Endocardium (SESAME). METHODS SESAME was performed in 5 naive pigs and 5 pigs with percutaneous aortic banding-induced left ventricular hypertrophy. Fluoroscopy and intracardiac echocardiography guided the procedures. Coronary guiding catheters and guidewires were used to mechanically enter the basal interventricular septum. Imparting a tip bend to the guidewire enabled intramyocardial navigation with multiple df. The guidewire trajectory determined the geometry of SESAME myotomy. The myocardium was lacerated using transcatheter electrosurgery. Cardiac function and tissue characteristics were assessed by cardiac magnetic resonance at baseline, postprocedure, and at 7- or 30-day follow-up. RESULTS SESAME myotomy along the intended trajectory was achieved in all animals. The myocardium splayed after laceration, increasing left ventricular outflow tract area (753 to 854 mm2, P=0.008). Two naive pigs developed ventricular septal defects due to excessively deep lacerations in thin baseline septa. No hypertrophy model pig, with increased septal thickness and left ventricular mass compared with naive pigs, developed ventricular septal defects. One animal developed left axis deviation on ECG but no higher conduction block was seen in any animal. Coronary artery branches were intact on angiography with no infarction on cardiac magnetic resonance late gadolinium imaging. Cardiac magnetic resonance chamber volumes, function, flow, and global strain were preserved. No myocardial edema was evident on cardiac magnetic resonance T1 mapping. CONCLUSIONS This preclinical study demonstrated feasibility of SESAME, a novel transcatheter myotomy to relieve left ventricular outflow tract obstruction. This percutaneous procedure using available devices, with a safe surgical precedent, is readily translatable into patients.
Collapse
Affiliation(s)
- Jaffar M Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Christopher G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Adam B Greenbaum
- Structural Heart and Valve Center, Emory University Hospital, Atlanta, GA (A.B.G., V.C.B., R.A.G.)
| | - Vasilis C Babaliaros
- Structural Heart and Valve Center, Emory University Hospital, Atlanta, GA (A.B.G., V.C.B., R.A.G.)
| | - Andrea E Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - William H Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Felicia Seemann
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Toby Rogers
- MedStar Washington Hospital Center, Washington, DC (T.R.)
| | - Michael A Eckhaus
- Division of Research Services, Office of Research Services (M.A.E.), NIH, Bethesda, MD
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| | - Robert A Guyton
- Structural Heart and Valve Center, Emory University Hospital, Atlanta, GA (A.B.G., V.C.B., R.A.G.)
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute (J.M.K., C.G.B., A.E.J., W.H.S., R.R., F.S., D.A.H., T.R., A.C.-W., R.J.L.), NIH, Bethesda, MD
| |
Collapse
|
17
|
Lee NG, Ramasawmy R, Lim Y, Campbell-Washburn AE, Nayak KS. MaxGIRF: Image reconstruction incorporating concomitant field and gradient impulse response function effects. Magn Reson Med 2022; 88:691-710. [PMID: 35445768 PMCID: PMC9232904 DOI: 10.1002/mrm.29232] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 02/04/2022] [Accepted: 02/23/2022] [Indexed: 02/03/2023]
Abstract
Purpose To develop and evaluate an improved strategy for compensating concomitant field effects in non‐Cartesian MRI at the time of image reconstruction. Theory We present a higher‐order reconstruction method, denoted as MaxGIRF, for non‐Cartesian imaging that simultaneously corrects off‐resonance, concomitant fields, and trajectory errors without requiring specialized hardware. Gradient impulse response functions are used to predict actual gradient waveforms, which are in turn used to estimate the spatiotemporally varying concomitant fields based on analytic expressions. The result, in combination with a reference field map, is an encoding matrix that incorporates a correction for all three effects. Methods The MaxGIRF reconstruction is applied to noiseless phantom simulations, spiral gradient‐echo imaging of an International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom, and axial and sagittal multislice spiral spin‐echo imaging of a healthy volunteer at 0.55 T. The MaxGIRF reconstruction was compared against previously established concomitant field‐compensation and image‐correction methods. Reconstructed images are evaluated qualitatively and quantitatively using normalized RMS error. Finally, a low‐rank approximation of MaxGIRF is used to reduce computational burden. The accuracy of the low‐rank approximation is studied as a function of minimum rank. Results The MaxGIRF reconstruction successfully mitigated blurring artifacts both in phantoms and in vivo and was effective in regions where concomitant fields counteract static off‐resonance, superior to the comparator method. A minimum rank of 8 and 30 for axial and sagittal scans, respectively, gave less than 2% error compared with the full‐rank reconstruction. Conclusions The MaxGIRF reconstruction simultaneously corrects off‐resonance, trajectory errors, and concomitant field effects. The impact of this method is greatest when imaging with longer readouts and/or at lower field strength. Click here for author‐reader discussions
Collapse
Affiliation(s)
- Nam G Lee
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Yongwan Lim
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Krishna S Nayak
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA.,Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
18
|
Bhattacharya I, Ramasawmy R, Javed A, Lowery M, Henry J, Mancini C, Machado T, Jones A, Julien-Williams P, Lederman RJ, Balaban RS, Chen MY, Moss J, Campbell-Washburn AE. Assessment of Lung Structure and Regional Function Using 0.55 T MRI in Patients With Lymphangioleiomyomatosis. Invest Radiol 2022; 57:178-186. [PMID: 34652290 PMCID: PMC9926400 DOI: 10.1097/rli.0000000000000832] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Contemporary lower-field magnetic resonance imaging (MRI) may offer advantages for lung imaging by virtue of the improved field homogeneity. The aim of this study was to evaluate the utility of lower-field MRI for combined morphologic imaging and regional lung function assessment. We evaluate low-field MRI in patients with lymphangioleiomyomatosis (LAM), a rare lung disease associated with parenchymal cysts and respiratory failure. MATERIALS AND METHODS We performed lung imaging on a prototype low-field (0.55 T) MRI system in 65 patients with LAM. T2-weighted imaging was used for assessment of lung morphology and to derive cyst scores, the percent of lung parenchyma occupied by cysts. Regional lung function was assessed using oxygen-enhanced MRI with breath-held ultrashort echo time imaging and inhaled 100% oxygen as a T1-shortening MR contrast agent. Measurements of percent signal enhancement from oxygen inhalation and percentage of lung with low oxygen enhancement, indicating functional deficits, were correlated with global pulmonary function test measurements taken within 2 days. RESULTS We were able to image cystic abnormalities using T2-weighted MRI in this patient population and calculate cyst score with strong correlation to computed tomography measurements (R = 0.86, P < 0.0001). Oxygen-enhancement maps demonstrated regional deficits in lung function of patients with LAM. Heterogeneity of oxygen enhancement between cysts was observed within individual patients. The percent low-enhancement regions showed modest, but significant, correlation with FEV1 (R = -0.37, P = 0.007), FEV1/FVC (R = -0.33, P = 0.02), and cyst score (R = 0.40, P = 0.02). The measured arterial blood ΔT1 between normoxia and hyperoxia, used as a surrogate for dissolved oxygen in blood, correlated with DLCO (R = -0.28, P = 0.03). CONCLUSIONS Using high-performance 0.55 T MRI, we were able to perform simultaneous imaging of pulmonary structure and regional function in patients with LAM.
Collapse
Affiliation(s)
- Ipshita Bhattacharya
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Margaret Lowery
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Jennifer Henry
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Christine Mancini
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Tania Machado
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Amanda Jones
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Patricia Julien-Williams
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Robert S Balaban
- Systems Biology Center, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Marcus Y Chen
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Joel Moss
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| |
Collapse
|
19
|
Javed A, Ramasawmy R, O'Brien K, Mancini C, Su P, Majeed W, Benkert T, Bhat H, Suffredini AF, Malayeri A, Campbell-Washburn AE. Self-gated 3D stack-of-spirals UTE pulmonary imaging at 0.55T. Magn Reson Med 2021; 87:1784-1798. [PMID: 34783391 DOI: 10.1002/mrm.29079] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 09/22/2021] [Accepted: 10/22/2021] [Indexed: 12/24/2022]
Abstract
PURPOSE To develop an isotropic high-resolution stack-of-spirals UTE sequence for pulmonary imaging at 0.55 Tesla by leveraging a combination of robust respiratory-binning, trajectory correction, and concomitant-field corrections. METHODS A stack-of-spirals golden-angle UTE sequence was used to continuously acquire data for 15.5 minutes. The data was binned to a stable respiratory phase based on superoinferior readout self-navigator signals. Corrections for trajectory errors and concomitant field artifacts, along with image reconstruction with conjugate gradient SENSE, were performed inline within the Gadgetron framework. Finally, data were retrospectively reconstructed to simulate scan times of 5, 8.5, and 12 minutes. Image quality was assessed using signal-to-noise, image sharpness, and qualitative reader scores. The technique was evaluated in healthy volunteers, patients with coronavirus disease 2019 infection, and patients with lung nodules. RESULTS The technique provided diagnostic quality images with parenchymal lung SNR of 3.18 ± 0.0.60, 4.57 ± 0.87, 5.45 ± 1.02, and 5.89 ± 1.28 for scan times of 5, 8.5, 12, and 15.5 minutes, respectively. The respiratory binning technique resulted in significantly sharper images (p < 0.001) as measured with relative maximum derivative at the diaphragm. Concomitant field corrections visibly improved sharpness of anatomical structures away from iso-center. The image quality was maintained with a slight loss in SNR for simulated scan times down to 8.5 minutes. Inline image reconstruction and artifact correction were achieved in <5 minutes. CONCLUSION The proposed pulmonary imaging technique combined efficient stack-of-spirals imaging with robust respiratory binning, concomitant field correction, and trajectory correction to generate diagnostic quality images with 1.75 mm isotropic resolution in 8.5 minutes on a high-performance 0.55 Tesla system.
Collapse
Affiliation(s)
- Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christine Mancini
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Pan Su
- Siemens Medical Solutions USA Inc., Malvern, Pennsylvania, USA
| | - Waqas Majeed
- Siemens Medical Solutions USA Inc., Malvern, Pennsylvania, USA
| | | | - Himanshu Bhat
- Siemens Medical Solutions USA Inc., Malvern, Pennsylvania, USA
| | - Anthony F Suffredini
- Critical Care Medicine Department, Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | - Ashkan Malayeri
- Department of Radiology and Imaging Sciences, Clinical Center, Department of Health and Human Services, National Institutes of Health, Bethesda, Maryland, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
20
|
Magalhães L, Silveira H, Prestes S, Costa Magalhães LK, Santana RA, Ramasawmy R, Oliveira J, Roque CCR, Silva Junior RCA, Fé N, Duarte R, Maciel M, Ortiz J, Morais R, Monteiro WM, Guerra JA, Barbosa Guerra MGV. Bioecological aspects of triatomines and marsupials as wild Trypanosoma cruzi reservoirs in urban, peri-urban and rural areas in the Western Brazilian Amazon. Med Vet Entomol 2021; 35:389-399. [PMID: 33394514 DOI: 10.1111/mve.12507] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 12/14/2020] [Accepted: 12/15/2020] [Indexed: 06/12/2023]
Abstract
In the Amazon region, Trypanosoma cruzi transmission cycles involve a great diversity of Triatominae vectors and mammal reservoirs. Some Rhodnius spp. mainly inhabit palm trees that act as microhabitats for hosts and vectors. The current study aimed to describe aspects of the bio-ecology of the vectors and reservoirs of T. cruzi in relation to human populations resident near areas with large quantities of palm trees, in rural, peri-urban and urban collection environments, located in the Western Brazilian Amazon. Rhodnius pictipes and Didelphis marsupialis were respectively the most predominant vector and reservoir, with rates of 71% for R. pictipes and 96.5% for D. marsupialis. The vast majority of T. cruzi isolates clustered with TcI. The most prevalent haplotype was TcI COII1 (69.7%). Mauritia flexuosa and Attalea phalerata were the main ecological indicators of infestation by triatomines. Birds were the most common food source (27,71%). T. cruzi isolated from R. robustus has the haplotype HUM-13, previously detected in a chronic Chagas patient living in the same area. Our results demonstrate the relevance of this study, with the occurrence of elevated infection rates in animals, and suggest the importance of the Amazon zones where there is a risk of infection in humans.
Collapse
Affiliation(s)
- L Magalhães
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - H Silveira
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
- Global Health and Tropical Medicine, GHTM, Instituto de Higiene e Medicina Tropical, IHMT, Universidade Nova de Lisboa, UNL, Lisboa, Portugal
| | - S Prestes
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - L K Costa Magalhães
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - R A Santana
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - R Ramasawmy
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - J Oliveira
- Fundação de Medicina Tropical - Heitor Vieira Dourado, Amazonas, Brasil
| | - C C R Roque
- Fundação de Medicina Tropical - Heitor Vieira Dourado, Amazonas, Brasil
| | | | - N Fé
- Fundação de Medicina Tropical - Heitor Vieira Dourado, Amazonas, Brasil
| | - R Duarte
- Fundação Oswaldo Cruz, Escola Nacional de Saúde Pública (ENSP), Rio de Janeiro, Brasil
| | - M Maciel
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - J Ortiz
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - R Morais
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
| | - W M Monteiro
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
- Fundação de Medicina Tropical - Heitor Vieira Dourado, Amazonas, Brasil
| | - J A Guerra
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
- Fundação de Medicina Tropical - Heitor Vieira Dourado, Amazonas, Brasil
| | - M G V Barbosa Guerra
- Programa de Pós-graduação em Medicina Tropical, Unversidade do Estado do Amazonas, Amazonas, Brasil
- Fundação de Medicina Tropical - Heitor Vieira Dourado, Amazonas, Brasil
| |
Collapse
|
21
|
Bhattacharya I, Ramasawmy R, Javed A, Chen MY, Benkert T, Majeed W, Lederman RJ, Moss J, Balaban RS, Campbell-Washburn AE. Oxygen-enhanced functional lung imaging using a contemporary 0.55 T MRI system. NMR Biomed 2021; 34:e4562. [PMID: 34080253 PMCID: PMC8377594 DOI: 10.1002/nbm.4562] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 04/30/2021] [Accepted: 05/04/2021] [Indexed: 05/14/2023]
Abstract
The purpose of this study was to evaluate oxygen-enhanced pulmonary imaging at 0.55 T with 3D stack-of-spirals ultrashort-TE (UTE) acquisition. Oxygen-enhanced pulmonary MRI offers the measurement of regional lung ventilation and perfusion using inhaled oxygen as a contrast agent. Low-field MRI systems equipped with contemporary hardware can provide high-quality structural lung imaging by virtue of the prolonged T2 *. Fortuitously, the T1 relaxivity of oxygen increases at lower field strengths, which is expected to improve the sensitivity of oxygen-enhanced lung MRI. We implemented a breath-held T1 -weighted 3D stack-of-spirals UTE acquisition with a 7 ms spiral-out readout. Measurement repeatability was assessed using five repetitions of oxygen-enhanced lung imaging in healthy volunteers (n = 7). The signal intensity at both normoxia and hyperoxia was strongly dependent on lung tissue density modulated by breath-hold volume during the five repetitions. A voxel-wise correction for lung tissue density improved the repeatability of percent signal enhancement maps (coefficient of variation = 34 ± 16%). Percent signal enhancement maps were compared in 15 healthy volunteers and 10 patients with lymphangioleiomyomatosis (LAM), a rare cystic disease known to reduce pulmonary function. We measured a mean percent signal enhancement of 9.0 ± 3.5% at 0.55 T in healthy volunteers, and reduced signal enhancement in patients with LAM (5.4 ± 4.8%, p = 0.02). The heterogeneity, estimated by the percent of lung volume exhibiting low enhancement, was significantly increased in patients with LAM compared with healthy volunteers (11.1 ± 6.0% versus 30.5 ± 13.1%, p = 0.01), illustrating the capability to measure regional functional deficits.
Collapse
Affiliation(s)
- Ipshita Bhattacharya
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Ahsan Javed
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Marcus Y Chen
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Thomas Benkert
- Siemens Healthcare GmbH, Henkestraße 127, 91052 Erlangen, Germany
| | - Waqas Majeed
- Siemens Medical Solutions USA Inc., 40 Liberty Boulevard, Malvern PA, 1935 USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Joel Moss
- Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| | - Robert S Balaban
- Systems Biology Center, Division of Intramural Research, National Heart, Lung, and Blood I nstitute, National Institutes of Health, Bethesda MD, USA 20892
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD, USA 20892
| |
Collapse
|
22
|
Kolandaivelu A, Bruce CG, Ramasawmy R, Yildirim DK, O'Brien KJ, Schenke WH, Rogers T, Campbell-Washburn AE, Lederman RJ, Herzka DA. Native contrast visualization and tissue characterization of myocardial radiofrequency ablation and acetic acid chemoablation lesions at 0.55 T. J Cardiovasc Magn Reson 2021; 23:50. [PMID: 33952312 PMCID: PMC8101152 DOI: 10.1186/s12968-020-00693-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 12/09/2020] [Indexed: 01/18/2023] Open
Abstract
PURPOSE Low-field (0.55 T) high-performance cardiovascular magnetic resonance (CMR) is an attractive platform for CMR-guided intervention as device heating is reduced around 7.5-fold compared to 1.5 T. This work determines the feasibility of visualizing cardiac radiofrequency (RF) ablation lesions at low field CMR and explores a novel alternative method for targeted tissue destruction: acetic acid chemoablation. METHODS N = 10 swine underwent X-ray fluoroscopy-guided RF ablation (6-7 lesions) and acetic acid chemoablation (2-3 lesions) of the left ventricle. Animals were imaged at 0.55 T with native contrast 3D-navigator gated T1-weighted T1w) CMR for lesion visualization, gated single-shot imaging to determine potential for real-time visualization of lesion formation, and T1 mapping to measure change in T1 in response to ablation. Seven animals were euthanized on ablation day and hearts imaged ex vivo. The remaining animals were imaged again in vivo at 21 days post ablation to observe lesion evolution. RESULTS Chemoablation lesions could be visualized and displayed much higher contrast than necrotic RF ablation lesions with T1w imaging. On the day of ablation, in vivo myocardial T1 dropped by 19 ± 7% in RF ablation lesion cores, and by 40 ± 7% in chemoablation lesion cores (p < 4e-5). In high resolution ex vivo imaging, with reduced partial volume effects, lesion core T1 dropped by 18 ± 3% and 42 ± 6% for RF and chemoablation, respectively. Mean, median, and peak lesion signal-to-noise ratio (SNR) were all at least 75% higher with chemoablation. Lesion core to myocardium contrast-to-noise (CNR) was 3.8 × higher for chemoablation. Correlation between in vivo and ex vivo CMR and histology indicated that the periphery of RF ablation lesions do not exhibit changes in T1 while the entire extent of chemoablation exhibits T1 changes. Correlation of T1w enhancing lesion volumes indicated in vivo estimates of lesion volume are accurate for chemoablation but underestimate extent of necrosis for RF ablation. CONCLUSION The visualization of coagulation necrosis from cardiac ablation is feasible using low-field high-performance CMR. Chemoablation produced a more pronounced change in lesion T1 than RF ablation, increasing SNR and CNR and thereby making it easier to visualize in both 3D navigator-gated and real-time CMR and more suitable for low-field imaging.
Collapse
Affiliation(s)
- Aravindan Kolandaivelu
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Chris G Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
- Biophysics and Biochemistry Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Kendall J O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - William H Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
- Medstar Washington Hospital Center, Washington, DC, USA
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
- Biophysics and Biochemistry Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, 20892, USA.
| |
Collapse
|
23
|
Yildirim DK, Bruce C, Uzun D, Rogers T, O'Brien K, Ramasawmy R, Campbell-Washburn A, Herzka DA, Lederman RJ, Kocaturk O. A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T. Magn Reson Med 2021; 86:1786-1801. [PMID: 33860962 DOI: 10.1002/mrm.28804] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 03/05/2021] [Accepted: 03/23/2021] [Indexed: 01/14/2023]
Abstract
PURPOSE This work aims to fabricate RF antenna components on metallic needle surfaces using biocompatible polyester tubing and conductive ink to develop an active interventional MRI needle for clinical use at 0.55 Tesla. METHODS A custom computer numeric control-based conductive ink printing method was developed. Based on electromagnetic simulation results, thin-film RF antennas were printed with conductive ink and used to fabricate a medical grade, 20-gauge (0.87 mm outer diameter), 90-mm long active interventional MRI needle. The MRI visibility performance of the active needle prototype was tested in vitro in 1 gel phantom and in vivo in 1 swine. A nearly identical active needle constructed using a 44 American Wire Gauge insulated copper wire-wound RF receiver antenna was a comparator. The RF-induced heating risk was evaluated in a gel phantom per American Society for Testing and Materials (ASTM) 2182-19. RESULTS The active needle prototype with printed RF antenna was clearly visible both in vitro and in vivo under MRI. The maximum RF-induced temperature rise of prototypes with printed RF antenna and insulated copper wire antenna after a 3.96 W/kg, 15 min. long scan were 1.64°C and 8.21°C, respectively. The increase in needle diameter was 98 µm and 264 µm for prototypes with printed RF antenna and copper wire-wound antenna, respectively. CONCLUSION The active needle prototype with conductive ink printed antenna provides distinct device visibility under MRI. Variations on the needle surface are mitigated compared to use of a 44 American Wire Gauge copper wire. RF-induced heating tests support device RF safety under MRI. The proposed method enables fabrication of small diameter active interventional MRI devices having complex geometries, something previously difficult using conventional methods.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christopher Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Dogangun Uzun
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
24
|
Chouhan MD, Ramasawmy R, Bainbridge A, Campbell‐Washburn A, Halligan S, Davies N, Walker‐Samuel S, Lythgoe MF, Mookerjee RP, Taylor SA. Liver perfusion MRI in a rodent model of cirrhosis: Agreement with bulk-flow phase-contrast MRI and noninvasive evaluation of inflammation in chronic liver disease using flow-sensitive alternating inversion recovery arterial spin labelling and tissue T1. NMR Biomed 2021; 34:e4423. [PMID: 33029872 PMCID: PMC8427466 DOI: 10.1002/nbm.4423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/28/2020] [Accepted: 09/18/2020] [Indexed: 05/03/2023]
Abstract
Noninvasive measurements of liver perfusion and fibrosis in cirrhotic small animals can help develop treatments for haemodynamic complications of liver disease. Here, we measure liver perfusion in cirrhotic rodents using flow-sensitive alternating inversion recovery arterial spin labelling (FAIR ASL), evaluating agreement with previously validated caval subtraction phase-contrast magnetic resonance imaging (PCMRI) total liver blood flow (TLBF). Baseline differences in cirrhotic rodents and the haemodynamic effects of acute inflammation were investigated using FAIR ASL and tissue T1. Sprague-Dawley rats (nine bile duct ligated [BDL] and ten sham surgery controls) underwent baseline hepatic FAIR ASL with T1 measurement and caval subtraction PCMRI (with two-dimensional infra-/supra-hepatic inferior vena caval studies), induction of inflammation with intravenous lipopolysaccharide (LPS) and repeat liver FAIR ASL with T1 measurement after ~90 minutes. The mean difference between FAIR ASL hepatic perfusion and caval subtraction PCMRI TLBF was -51 ± 30 ml/min/100 g (Bland-Altman 95% limits-of-agreement ±258 ml/min/100 g). The FAIR ASL coefficient of variation was smaller than for caval subtraction PCMRI (29.3% vs 50.1%; P = .03). At baseline, FAIR ASL liver perfusion was lower in BDL rats (199 ± 32 ml/min/100 g vs sham 316 ± 24 ml/min/100 g; P = .01) but liver T1 was higher (BDL 1533 ± 50 vs sham 1256 ± 18 ms; P = .0004). Post-LPS FAIR ASL liver perfusion response differences were observed between sham/BDL rats (P = .02), approaching significance in sham (+78 ± 33 ml/min/100 g; P = .06) but not BDL rats (-49 ± 40 ml/min/100 g; P = .47). Post-LPS differences in liver tissue T1 were nonsignificant (P = .35). FAIR ASL hepatic perfusion and caval subtraction PCMRI TLBF agreement was modest, with significant baseline FAIR ASL liver perfusion and tissue T1 differences in rodents with advanced cirrhosis compared with controls. Following inflammatory stress, differences in hepatic perfusion response were detected between cirrhotic/control animals, but liver T1 was unaffected. Findings underline the potential of FAIR ASL in the assessment of vasoactive treatments for patients with chronic liver disease and inflammation.
Collapse
|
25
|
Agliardi G, Liuzzi AR, Hotblack A, De Feo D, Núñez N, Stowe CL, Friebel E, Nannini F, Rindlisbacher L, Roberts TA, Ramasawmy R, Williams IP, Siow BM, Lythgoe MF, Kalber TL, Quezada SA, Pule MA, Tugues S, Straathof K, Becher B. Intratumoral IL-12 delivery empowers CAR-T cell immunotherapy in a pre-clinical model of glioblastoma. Nat Commun 2021; 12:444. [PMID: 33469002 PMCID: PMC7815781 DOI: 10.1038/s41467-020-20599-x] [Citation(s) in RCA: 133] [Impact Index Per Article: 44.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Accepted: 12/11/2020] [Indexed: 01/29/2023] Open
Abstract
Glioblastoma multiforme (GBM) is the most common and aggressive form of primary brain cancer, for which effective therapies are urgently needed. Chimeric antigen receptor (CAR)-based immunotherapy represents a promising therapeutic approach, but it is often impeded by highly immunosuppressive tumor microenvironments (TME). Here, in an immunocompetent, orthotopic GBM mouse model, we show that CAR-T cells targeting tumor-specific epidermal growth factor receptor variant III (EGFRvIII) alone fail to control fully established tumors but, when combined with a single, locally delivered dose of IL-12, achieve durable anti-tumor responses. IL-12 not only boosts cytotoxicity of CAR-T cells, but also reshapes the TME, driving increased infiltration of proinflammatory CD4+ T cells, decreased numbers of regulatory T cells (Treg), and activation of the myeloid compartment. Importantly, the immunotherapy-enabling benefits of IL-12 are achieved with minimal systemic effects. Our findings thus show that local delivery of IL-12 may be an effective adjuvant for CAR-T cell therapy for GBM.
Collapse
Affiliation(s)
- Giulia Agliardi
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Anna Rita Liuzzi
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland
| | - Alastair Hotblack
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Donatella De Feo
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland
| | - Nicolás Núñez
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland
| | - Cassandra L Stowe
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Ekaterina Friebel
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland
| | - Francesco Nannini
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Lukas Rindlisbacher
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland
| | - Thomas A Roberts
- Centre for Advanced Biomedical Imaging (CABI), University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Rajiv Ramasawmy
- Centre for Advanced Biomedical Imaging (CABI), University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Iwan P Williams
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Bernard M Siow
- Centre for Advanced Biomedical Imaging (CABI), University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
- The Francis Crick Institute, NW1 1AT, London, UK
| | - Mark F Lythgoe
- Centre for Advanced Biomedical Imaging (CABI), University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Tammy L Kalber
- Centre for Advanced Biomedical Imaging (CABI), University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Sergio A Quezada
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Martin A Pule
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK
| | - Sonia Tugues
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland
| | - Karin Straathof
- Research Department of Hematology, Cancer Institute, University College London, Paul O'Gorman Building, WC1E 6DD, London, UK.
- UCL Great Ormond Street Institute of Child Health Biomedical Research Centre, WC1N 1EH, London, UK.
| | - Burkhard Becher
- Institute of Experimental Immunology, University of Zurich, 8057, Zurich, Switzerland.
| |
Collapse
|
26
|
Agliardi G, Liuzzi AR, Hotblack A, De Feo D, Núñez N, Friebel E, Nannini F, Roberts T, Ramasawmy R, Stowe C, Williams I, Siow B, Lythgoe M, Kalber T, Quezada S, Pule M, Tugues S, Becher B, Straathof K. IMMU-16. INTRA-TUMOURAL IL-12 DELIVERY ENABLES CAR T-CELL IMMUNOTHERAPY FOR HIGH-GRADE GLIOMA. Neuro Oncol 2020. [PMCID: PMC7715834 DOI: 10.1093/neuonc/noaa222.372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Treatment with T-cells redirected to tumour specificity with a chimeric antigen receptor (CAR) may be well suited to treat intracranial tumours due to the ability of T-cells to access the central nervous system and migrate to infiltrative sites of disease. In adult glioblastoma, a case report of local and distant eradication of intracranial and spinal tumour deposits following intraventricular infusion of IL13Ra2-CAR T-cells indicates the potential of this approach. However, in contrast to the sustained complete remissions observed in haematological malignancies, in the majority of patients with glioblastoma CAR T-cell therapy has not resulted in clinical benefit. Tumour heterogeneity and the highly immune inhibitory tumour microenvironment (TME) are likely key barriers to achieving durable anti-tumour immunity. Here use intra-tumoural administration of IL-12 to enable CAR T-cell immunity. We employed CAR-T cells targeting the tumour-specific epidermal growth factor variant III (EGFRvIII). In an immunocompetent orthotopic mouse model of high-grade glioma, we show that CAR-T cells alone failed to control fully established tumour, but when combined with a single, locally delivered dose of IL-12, durable antitumor responses were achieved. IL-12 not only boosted cytotoxicity of CAR T-cells, but also reshaped the TME driving increased infiltration of proinflammatory CD4+ T-cells, decreased numbers of regulatory T-cells (Tregs) and activation of the myeloid compartment. Critically, immunotherapy enabling benefits of IL-12 were achieved with minimal systemic effects. Our findings show that local delivery of IL-12 is an effective adjuvant for CAR-T cell therapy for high-grade glioma. Assessment of application in high-risk childhood brain tumours is ongoing.
Collapse
Affiliation(s)
| | - Anna Rita Liuzzi
- Institute of Experimental Immunology, University of Zurich, Zurich, CH, Switzerland
| | | | - Donatella De Feo
- Institute of Experimental Immunology, University of Zurich, Zurich, CH, Switzerland
| | - Nicolás Núñez
- Institute of Experimental Immunology, University of Zurich, Zurich, CH, Switzerland
| | - Ekaterina Friebel
- Institute of Experimental Immunology, University of Zurich, Zurich, CH, Switzerland
| | | | - Thomas Roberts
- UCL Centre for Advanced Biomedical Imaging, London, GB, United Kingdom
| | - Rajiv Ramasawmy
- UCL Centre for Advanced Biomedical Imaging, London, GB, United Kingdom
| | | | | | - Bernard Siow
- UCL Centre for Advanced Biomedical Imaging, London, GB, United Kingdom
- Francis Crick Institute, London, GB, United Kingdom
| | - Mark Lythgoe
- UCL Centre for Advanced Biomedical Imaging, London, GB, United Kingdom
| | - Tammy Kalber
- UCL Centre for Advanced Biomedical Imaging, London, GB, United Kingdom
| | | | - Martin Pule
- UCL Cancer Institute, London, GB, United Kingdom
| | - Sonia Tugues
- Institute of Experimental Immunology, University of Zurich, Zurich, CH, Switzerland
| | - Burkhard Becher
- Institute of Experimental Immunology, University of Zurich, Zurich, CH, Switzerland
| | - Karin Straathof
- UCL Great Ormond Street Institute of Child Health, London, GB, United Kingdom
- UCL Cancer Institute, London, GB, United Kingdom
| |
Collapse
|
27
|
Roberts TA, Hyare H, Agliardi G, Hipwell B, d'Esposito A, Ianus A, Breen-Norris JO, Ramasawmy R, Taylor V, Atkinson D, Punwani S, Lythgoe MF, Siow B, Brandner S, Rees J, Panagiotaki E, Alexander DC, Walker-Samuel S. Noninvasive diffusion magnetic resonance imaging of brain tumour cell size for the early detection of therapeutic response. Sci Rep 2020; 10:9223. [PMID: 32514049 PMCID: PMC7280197 DOI: 10.1038/s41598-020-65956-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 05/07/2020] [Indexed: 01/09/2023] Open
Abstract
Cancer cells differ in size from those of their host tissue and are known to change in size during the processes of cell death. A noninvasive method for monitoring cell size would be highly advantageous as a potential biomarker of malignancy and early therapeutic response. This need is particularly acute in brain tumours where biopsy is a highly invasive procedure. Here, diffusion MRI data were acquired in a GL261 glioma mouse model before and during treatment with Temozolomide. The biophysical model VERDICT (Vascular Extracellular and Restricted Diffusion for Cytometry in Tumours) was applied to the MRI data to quantify multi-compartmental parameters connected to the underlying tissue microstructure, which could potentially be useful clinical biomarkers. These parameters were compared to ADC and kurtosis diffusion models, and, measures from histology and optical projection tomography. MRI data was also acquired in patients to assess the feasibility of applying VERDICT in a range of different glioma subtypes. In the GL261 gliomas, cellular changes were detected according to the VERDICT model in advance of gross tumour volume changes as well as ADC and kurtosis models. VERDICT parameters in glioblastoma patients were most consistent with the GL261 mouse model, whilst displaying additional regions of localised tissue heterogeneity. The present VERDICT model was less appropriate for modelling more diffuse astrocytomas and oligodendrogliomas, but could be tuned to improve the representation of these tumour types. Biophysical modelling of the diffusion MRI signal permits monitoring of brain tumours without invasive intervention. VERDICT responds to microstructural changes induced by chemotherapy, is feasible within clinical scan times and could provide useful biomarkers of treatment response.
Collapse
Affiliation(s)
- Thomas A Roberts
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Harpreet Hyare
- Centre for Medical Imaging, Division of Medicine, University College London, London, UK
- Department of Brain Repair and Rehabilitation, UCL Institute of Neurology, London, UK
| | - Giulia Agliardi
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Ben Hipwell
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Angela d'Esposito
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Andrada Ianus
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | | | - Rajiv Ramasawmy
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Valerie Taylor
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - David Atkinson
- Centre for Medical Imaging, Division of Medicine, University College London, London, UK
| | - Shonit Punwani
- Centre for Medical Imaging, Division of Medicine, University College London, London, UK
| | - Mark F Lythgoe
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | - Bernard Siow
- Centre for Advanced Biomedical Imaging, University College London, London, UK
| | | | - Jeremy Rees
- National Hospital for Neurology and Neurosurgery, London, UK
| | - Eleftheria Panagiotaki
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Daniel C Alexander
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Simon Walker-Samuel
- Centre for Advanced Biomedical Imaging, University College London, London, UK.
| |
Collapse
|
28
|
Restivo MC, Ramasawmy R, Bandettini WP, Herzka DA, Campbell-Washburn AE. Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI. Magn Reson Med 2020; 84:2364-2375. [PMID: 32291845 DOI: 10.1002/mrm.28278] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 03/10/2020] [Accepted: 03/13/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE Low-field MRI offers favorable physical properties for SNR-efficient long readout acquisitions such as spiral and EPI. We used a 0.55 tesla (T) MRI system equipped with high-performance hardware to increase the sampling duty cycle and extend the TR of balanced steady-state free precession (bSSFP) cardiac cine acquisitions, which typically are limited by banding artifacts. METHODS We developed a high-efficiency spiral in-out bSSFP acquisition, with zeroth- and first-gradient moment nulling, and an EPI bSSFP acquisition for cardiac cine imaging using a contemporary MRI system modified to operate at 0.55T. Spiral in-out and EPI bSSFP cine protocols, with TR = 8 ms, were designed to maintain both spatiotemporal resolution and breath-hold length. Simulations, phantom imaging, and healthy volunteer imaging studies (n = 12) were performed to assess SNR and image quality using these high sampling duty-cycle bSSFP sequences. RESULTS Spiral in-out bSSFP performed favorably at 0.55T and generated good image quality, whereas EPI bSSFP suffered motion and flow artifacts. There was no difference in ejection fraction comparing spiral in-out with standard Cartesian imaging. Moreover, human images demonstrated a 79% ± 21% increase in myocardial SNR using spiral in-out bSSFP and 50% ± 14% increase in SNR using EPI bSSFP as compared with the reference Cartesian acquisition. Spiral in-out acquisitions at 0.55T recovered 69% ± 14% of the myocardial SNR at 1.5T. CONCLUSION Efficient bSSFP spiral in-out provided high-quality cardiac cine imaging and SNR recovery on a high-performance 0.55T MRI system.
Collapse
Affiliation(s)
- Matthew C Restivo
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - W Patricia Bandettini
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Adrienne E Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
29
|
Campbell-Washburn AE, Ramasawmy R, Restivo MC, Bhattacharya I, Basar B, Herzka DA, Hansen MS, Rogers T, Bandettini WP, McGuirt DR, Mancini C, Grodzki D, Schneider R, Majeed W, Bhat H, Xue H, Moss J, Malayeri AA, Jones EC, Koretsky AP, Kellman P, Chen MY, Lederman RJ, Balaban RS. Opportunities in Interventional and Diagnostic Imaging by Using High-Performance Low-Field-Strength MRI. Radiology 2019; 293:384-393. [PMID: 31573398 PMCID: PMC6823617 DOI: 10.1148/radiol.2019190452] [Citation(s) in RCA: 191] [Impact Index Per Article: 38.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 08/06/2019] [Accepted: 08/15/2019] [Indexed: 12/24/2022]
Abstract
Background Commercial low-field-strength MRI systems are generally not equipped with state-of-the-art MRI hardware, and are not suitable for demanding imaging techniques. An MRI system was developed that combines low field strength (0.55 T) with high-performance imaging technology. Purpose To evaluate applications of a high-performance low-field-strength MRI system, specifically MRI-guided cardiovascular catheterizations with metallic devices, diagnostic imaging in high-susceptibility regions, and efficient image acquisition strategies. Materials and Methods A commercial 1.5-T MRI system was modified to operate at 0.55 T while maintaining high-performance hardware, shielded gradients (45 mT/m; 200 T/m/sec), and advanced imaging methods. MRI was performed between January 2018 and April 2019. T1, T2, and T2* were measured at 0.55 T; relaxivity of exogenous contrast agents was measured; and clinical applications advantageous at low field were evaluated. Results There were 83 0.55-T MRI examinations performed in study participants (45 women; mean age, 34 years ± 13). On average, T1 was 32% shorter, T2 was 26% longer, and T2* was 40% longer at 0.55 T compared with 1.5 T. Nine metallic interventional devices were found to be intrinsically safe at 0.55 T (<1°C heating) and MRI-guided right heart catheterization was performed in seven study participants with commercial metallic guidewires. Compared with 1.5 T, reduced image distortion was shown in lungs, upper airway, cranial sinuses, and intestines because of improved field homogeneity. Oxygen inhalation generated lung signal enhancement of 19% ± 11 (standard deviation) at 0.55 T compared with 7.6% ± 6.3 at 1.5 T (P = .02; five participants) because of the increased T1 relaxivity of oxygen (4.7e-4 mmHg-1sec-1). Efficient spiral image acquisitions were amenable to low field strength and generated increased signal-to-noise ratio compared with Cartesian acquisitions (P < .02). Representative imaging of the brain, spine, abdomen, and heart generated good image quality with this system. Conclusion This initial study suggests that high-performance low-field-strength MRI offers advantages for MRI-guided catheterizations with metal devices, MRI in high-susceptibility regions, and efficient imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Grist in this issue.
Collapse
Affiliation(s)
- Adrienne E. Campbell-Washburn
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Rajiv Ramasawmy
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Matthew C. Restivo
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Ipshita Bhattacharya
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Burcu Basar
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Daniel A. Herzka
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Michael S. Hansen
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Toby Rogers
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - W. Patricia Bandettini
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Delaney R. McGuirt
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Christine Mancini
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - David Grodzki
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Rainer Schneider
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Waqas Majeed
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Himanshu Bhat
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Hui Xue
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Joel Moss
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Ashkan A. Malayeri
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Elizabeth C. Jones
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Alan P. Koretsky
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Peter Kellman
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Marcus Y. Chen
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Robert J. Lederman
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| | - Robert S. Balaban
- From the Cardiovascular Branch, Division of Intramural Research,
National Heart, Lung, and Blood Institute, National Institutes of Health,
Bethesda, Md (A.E.C.W., R.R., M.C.R., I.B., B.B., D.A.H., M.S.H., T.R., W.P.B.,
D.R.M., C.M., M.Y.C., R.J.L.); Siemens Healthcare GmbH, Erlangen, Germany (D.G.,
R.S.); Siemens Medical Solutions Inc, Malvern Pa (W.M., H.B.); Systems Biology
Center, Division of Intramural Research, National Heart, Lung, and Blood
Institute, National Institutes of Health, 10 Center Dr, Building 10, Room
4C-1581, Bethesda, MD 20892-1458 (H.X., P.K., R.S.B.); Pulmonary Branch,
Division of Intramural Research, National Heart, Lung, and Blood Institute,
National Institutes of Health, Bethesda, MD (J.M.); Department of Radiology and
Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Md
(A.A.M., E.C.J.); and Laboratory of Functional and Molecular Imaging, Division
of Intramural Research, National Institute of Neurologic Disorders and Stroke,
National Institutes of Health, Bethesda, Md (A.P.K.)
| |
Collapse
|
30
|
Finnerty E, Ramasawmy R, O’Callaghan J, Connell JJ, Lythgoe M, Shmueli K, Thomas DL, Walker‐Samuel S. Noninvasive quantification of oxygen saturation in the portal and hepatic veins in healthy mice and those with colorectal liver metastases using QSM MRI. Magn Reson Med 2019; 81:2666-2675. [PMID: 30450573 PMCID: PMC6588010 DOI: 10.1002/mrm.27571] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Revised: 09/10/2018] [Accepted: 09/26/2018] [Indexed: 12/30/2022]
Abstract
PURPOSE This preclinical study investigated the use of QSM MRI to noninvasively measure venous oxygen saturation (SvO2) in the hepatic and portal veins. METHODS QSM data were acquired from a cohort of healthy mice (n = 10) on a 9.4 Tesla MRI scanner under normoxic and hyperoxic conditions. Susceptibility was measured in the portal and hepatic veins and used to calculate SvO2 in each vessel under each condition. Blood was extracted from the inferior vena cava of 3 of the mice under each condition, and SvO2 was measured with a blood gas analyzer for comparison. QSM data were also acquired from a cohort of mice bearing liver tumors under normoxic conditions. Susceptibility was measured, and SvO2 calculated in the portal and hepatic veins and compared to the healthy mice. Statistical significance was assessed using a Wilcoxon matched-pairs signed rank test (normoxic vs. hyperoxic) or a Mann-Whitney test (healthy vs. tumor bearing). RESULTS SvO2 calculated from QSM measurements in healthy mice under hyperoxia showed significant increases of 15% in the portal vein (P < 0.05) and 21% in the hepatic vein (P < 0.01) versus normoxia. These values agreed with inferior vena cava measurements from the blood gas analyzer (26% increase). SvO2 in the hepatic vein was significantly lower in the colorectal liver metastases cohort (30% ± 11%) than the healthy mice (53% ± 17%) (P < 0.05); differences in the portal vein were not significant. CONCLUSION QSM is a feasible tool for noninvasively measuring SvO2 in the liver and can detect differences due to increased oxygen consumption in livers bearing colorectal metastases.
Collapse
Affiliation(s)
- Eoin Finnerty
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUnited Kingdom
| | - Rajiv Ramasawmy
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUnited Kingdom
| | - James O’Callaghan
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUnited Kingdom
| | - John J. Connell
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUnited Kingdom
| | - Mark Lythgoe
- Department of MedicineUCL Institute of Child Health, University College LondonLondonUnited Kingdom
| | - Karin Shmueli
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUnited Kingdom
| | - David L. Thomas
- Institute of NeurologyUniversity College LondonLondonUnited Kingdom
| | | |
Collapse
|
31
|
Restivo MC, Campbell-Washburn AE, Kellman P, Xue H, Ramasawmy R, Hansen MS. A framework for constraining image SNR loss due to MR raw data compression. MAGMA 2018; 32:213-225. [PMID: 30361947 DOI: 10.1007/s10334-018-0709-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 10/03/2018] [Accepted: 10/15/2018] [Indexed: 11/25/2022]
Abstract
INTRODUCTION Computationally intensive image reconstruction algorithms can be used online during MRI exams by streaming data to remote high-performance computers. However, data acquisition rates often exceed the bandwidth of the available network resources creating a bottleneck. Data compression is, therefore, desired to ensure fast data transmission. METHODS The added noise variance due to compression was determined through statistical analysis for two compression libraries (one custom and one generic) that were implemented in this framework. Limiting the compression error variance relative to the measured thermal noise allowed for image signal-to-noise ratio loss to be explicitly constrained. RESULTS Achievable compression ratios are dependent on image SNR, user-defined SNR loss tolerance, and acquisition type. However, a 1% reduction in SNR yields approximately four to ninefold compression ratios across MRI acquisition strategies. For free-breathing cine data reconstructed in the cloud, the streaming bandwidth was reduced from 37 to 6.1 MB/s, alleviating the network transmission bottleneck. CONCLUSION Our framework enabled data compression for online reconstructions and allowed SNR loss to be constrained based on a user-defined SNR tolerance. This practical tool will enable real-time data streaming and greater than fourfold faster cloud upload times.
Collapse
Affiliation(s)
- Matthew C Restivo
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Rm B1D47, 10 Center Dr, Bethesda, MD, 20814, USA.
| | - Adrienne E Campbell-Washburn
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Rm B1D47, 10 Center Dr, Bethesda, MD, 20814, USA
| | - Peter Kellman
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Rm B1D47, 10 Center Dr, Bethesda, MD, 20814, USA
| | - Hui Xue
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Rm B1D47, 10 Center Dr, Bethesda, MD, 20814, USA
| | - Rajiv Ramasawmy
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Rm B1D47, 10 Center Dr, Bethesda, MD, 20814, USA
| | - Michael S Hansen
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Rm B1D47, 10 Center Dr, Bethesda, MD, 20814, USA
| |
Collapse
|
32
|
Zhu Y, Ramasawmy R, Johnson SP, Taylor V, Gibb A, Pedley RB, Chattopadhyay N, Lythgoe MF, Golay X, Bradley D, Walker-Samuel S. Non-invasive imaging of disrupted protein homeostasis induced by proteasome inhibitor treatment using chemical exchange saturation transfer MRI. Sci Rep 2018; 8:15068. [PMID: 30305717 PMCID: PMC6180115 DOI: 10.1038/s41598-018-33549-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 10/02/2018] [Indexed: 11/09/2022] Open
Abstract
Proteasome inhibitors (PIs) are now standard of care for several cancers, and noninvasive biomarkers of treatment response are critically required for early patient stratification and treatment personalization. The present study evaluated whether chemical exchange (CEST) magnetic resonance imaging (MRI) can provide measurements that can be used as the noninvasive biomarkers of proteasome inhibition, alongside diffusion MRI and relaxometry. The sensitivity of human colorectal carcinoma cells to the PI Ixazomib was assessed via in vitro and in vivo dose-response experiments. Acute in vivo response to Ixazomib was assessed at three dosing concentrations, using CEST MRI (amide, amine, hydroxyl signals), diffusion MRI (ADC) and relaxometry (T1, T2). These responses were further evaluated with the known histological markers for Ixazomib and Bradford assay ex vivo. The CEST signal from amides and amines increased in proportion to Ixazomib dose in colorectal cancer xenografts. The cell lines differed in their sensitivity to Ixazomib, which was reflected in the MRI measurements. A mild stimulation in tumor growth was observed at low Ixazomib doses. Our results identify CEST MRI as a promising method for safely and noninvasively monitoring disrupted tumor protein homeostasis induced by proteasome inhibitor treatment, and for stratifying sensitivity between tumor types.
Collapse
Affiliation(s)
- Yanan Zhu
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, WC1E 6DD, United Kingdom
| | - Rajiv Ramasawmy
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, WC1E 6DD, United Kingdom
| | - Sean Peter Johnson
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, WC1E 6DD, United Kingdom
| | - Valerie Taylor
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, WC1E 6DD, United Kingdom
| | - Alasdair Gibb
- Neuroscience, Physiology & Pharmacology, University College London, London, WC1E 6BT, United Kingdom
| | - R Barbara Pedley
- Cancer Institute, University College London, London, WC1E 6DD, United Kingdom
| | - Nibedita Chattopadhyay
- Cancer Pharmacology, Takeda Pharmaceutical International Corporation, Cambridge, MA, 02139, United States
| | - Mark F Lythgoe
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, WC1E 6DD, United Kingdom
| | - Xavier Golay
- Institute of Neurology, University College London, London, WC1N 3BG, United Kingdom
| | - Daniel Bradley
- Biomedical Imaging Group, Takeda Pharmaceutical International Corporation, Cambridge, MA, 02139, United States
| | - Simon Walker-Samuel
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, WC1E 6DD, United Kingdom.
| |
Collapse
|
33
|
d'Esposito A, Sweeney PW, Ali M, Saleh M, Ramasawmy R, Roberts TA, Agliardi G, Desjardins A, Lythgoe MF, Pedley RB, Shipley R, Walker-Samuel S. Computational fluid dynamics with imaging of cleared tissue and of in vivo perfusion predicts drug uptake and treatment responses in tumours. Nat Biomed Eng 2018; 2:773-787. [PMID: 31015649 DOI: 10.1038/s41551-018-0306-y] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Accepted: 09/06/2018] [Indexed: 01/02/2023]
Abstract
Understanding the uptake of a drug by diseased tissue, and the drug's subsequent spatiotemporal distribution, are central factors in the development of effective targeted therapies. However, the interaction between the pathophysiology of diseased tissue and individual therapeutic agents can be complex, and can vary across tissue types and across subjects. Here, we show that the combination of mathematical modelling, high-resolution optical imaging of intact and optically cleared tumour tissue from animal models, and in vivo imaging of vascular perfusion predicts the heterogeneous uptake, by large tissue samples, of specific therapeutic agents, as well as their spatiotemporal distribution. In particular, by using murine models of colorectal cancer and glioma, we report and validate predictions of steady-state blood flow and intravascular and interstitial fluid pressure in tumours, of the spatially heterogeneous uptake of chelated gadolinium by tumours, and of the effect of a vascular disrupting agent on tumour vasculature.
Collapse
Affiliation(s)
- Angela d'Esposito
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | - Paul W Sweeney
- Department of Mechanical Engineering, University College London, London, UK
| | - Morium Ali
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | - Magdy Saleh
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | - Rajiv Ramasawmy
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | - Thomas A Roberts
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | - Giulia Agliardi
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | - Adrien Desjardins
- Department of Medical Physics, University College London, London, UK
| | - Mark F Lythgoe
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK
| | | | - Rebecca Shipley
- Department of Mechanical Engineering, University College London, London, UK.
| | - Simon Walker-Samuel
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London, UK.
| |
Collapse
|
34
|
Ramasawmy R, Rogers T, Alcantar MA, McGuirt DR, Khan JM, Kellman P, Xue H, Faranesh AZ, Campbell-Washburn AE, Lederman RJ, Herzka DA. Blood volume measurement using cardiovascular magnetic resonance and ferumoxytol: preclinical validation. J Cardiovasc Magn Reson 2018; 20:62. [PMID: 30201013 PMCID: PMC6131893 DOI: 10.1186/s12968-018-0486-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Accepted: 08/20/2018] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND The hallmark of heart failure is increased blood volume. Quantitative blood volume measures are not conveniently available and are not tested in heart failure management. We assess ferumoxytol, a marketed parenteral iron supplement having a long intravascular half-life, to measure the blood volume with cardiovascular magnetic resonance (CMR). METHODS Swine were administered 0.7 mg/kg ferumoxytol and blood pool T1 was measured repeatedly for an hour to characterize contrast agent extraction and subsequent effect on Vblood estimates. We compared CMR blood volume with a standard carbon monoxide rebreathing method. We then evaluated three abbreviated acquisition protocols for bias and precision. RESULTS Mean plasma volume estimated by ferumoxytol was 61.9 ± 4.3 ml/kg. After adjustment for hematocrit the resultant mean blood volume was 88.1 ± 9.4 ml/kg, which agreed with carbon monoxide measures (91.1 ± 18.9 ml/kg). Repeated measurements yielded a coefficient of variation of 6.9%, and Bland-Altman repeatability coefficient of 14%. The blood volume estimates with abbreviated protocols yielded small biases (mean differences between 0.01-0.06 L) and strong correlations (r2 between 0.97-0.99) to the reference values indicating clinical feasibility. CONCLUSIONS In this swine model, ferumoxytol CMR accurately measures plasma volume, and with correction for hematocrit, blood volume. Abbreviated protocols can be added to diagnostic CMR examination for heart failure within 8 min.
Collapse
Affiliation(s)
- Rajiv Ramasawmy
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Toby Rogers
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Miguel A. Alcantar
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Delaney R. McGuirt
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Jaffar M. Khan
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Peter Kellman
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Hui Xue
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Anthony Z. Faranesh
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Adrienne E. Campbell-Washburn
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Robert J. Lederman
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| | - Daniel A. Herzka
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD 20892 USA
| |
Collapse
|
35
|
Yaras YS, Satir S, Ozsoy C, Ramasawmy R, Campbell-Washburn AE, Lederman RJ, Kocaturk O, Degertekin FL. Acousto-Optic Catheter Tracking Sensor for Interventional MRI Procedures. IEEE Trans Biomed Eng 2018; 66:1148-1154. [PMID: 30188810 DOI: 10.1109/tbme.2018.2868830] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE The objective of this paper is to introduce an acousto-optic optical fiber sensor for tracking catheter position during interventional magnetic resonance imaging (MRI) to overcome RF induced heating of active markers. METHODS The sensor uses a miniature coil coupled to a piezoelectric transducer, which is in turn mechanically connected to an optical fiber. The piezoelectric transducer converts the RF signal to acoustic waves in the optical fiber over a region including a fiber Bragg grating (FBG). The elastic waves in the fiber modulates the FBG geometry and hence the reflected light in the optical fiber. Since the coil is much smaller than the RF wavelength and the signal is transmitted on the dielectric optical fiber, the sensor effectively reduces RF induced heating risk. Proof of concept prototypes of the sensor are implemented using commercially available piezoelectric transducers and optical fibers with FBGs. The prototypes are characterized in a 1.5 T MRI system in comparison with an active tracking marker. RESULTS Acousto-optical sensor shows linear response with flip angle and it can be used to detect signals from multiple coils for potential orientation detection. It has been successfully used to detect the position of a tacking coil in phantom in an imaging experiment. CONCLUSION Acousto-optical sensing is demonstrated for tracking catheters during interventional MRI. Real-time operation of the sensor requires sensitivity improvements like using a narrow band FBG. SIGNIFICANCE Acousto-optics provides a compact solution to sense RF signals in MRI with dielectric transmission lines.
Collapse
|
36
|
Khan JM, Rogers T, Schenke WH, Greenbaum AB, Babaliaros VC, Paone G, Ramasawmy R, Chen MY, Herzka DA, Lederman RJ. Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve. Catheter Cardiovasc Interv 2018; 92:E175-E184. [PMID: 29405564 PMCID: PMC6078835 DOI: 10.1002/ccd.27531] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Revised: 01/15/2018] [Accepted: 01/15/2018] [Indexed: 11/07/2022]
Abstract
OBJECTIVES Pledget-assisted suture tricuspid valve annuloplasty (PASTA) is a novel technique using marketed equipment to deliver percutaneous trans-annular sutures to create a double-orifice tricuspid valve. BACKGROUND Tricuspid regurgitation is a malignant disease with high surgical mortality and no commercially available transcatheter solution in the US. METHODS Two iterations of PASTA were tested using trans-apical or trans-jugular access in swine. Catheters directed paired coronary guidewires to septal and lateral targets on the tricuspid annulus under fluoroscopic and echocardiographic guidance. Guidewires were electrified to traverse the annular targets and exchanged for pledgeted sutures. The sutures were drawn together and knotted, apposing septal and lateral targets, creating a double orifice tricuspid valve. RESULTS Twenty-two pigs underwent PASTA. Annular and chamber dimensions were reduced (annular area, 10.1 ± 0.8 cm2 to 3.8 ± 1.5 cm2 (naïve) and 13.1 ± 1.5 cm2 to 6.2 ± 1.0 cm2 (diseased); septal-lateral diameter, 3.9 ± 0.3 mm to 1.4 ± 0.6 mm (naïve) and 4.4 ± 0.4 mm to 1.7 ± 1.0 mm (diseased); and right ventricular end-diastolic volume, 94 ± 13 ml to 85 ± 14 ml (naïve) and 157 ± 25 ml to 143 ± 20 ml (diseased)). MRI derived tricuspid regurgitation fraction fell from 32 ± 12% to 4 ± 5%. Results were sustained at 30 days. Pledget pull-through force was five-fold higher (40.6 ± 11.7N vs 8.0 ± 2.6N, P < .01) using this strategy compared to single puncture techniques used to anchor current investigational devices. Serious complications were related to apical access. CONCLUSIONS PASTA reduces annular dimensions and tricuspid regurgitation in pigs. It may be cautiously applied to selected patients with severe tricuspid regurgitation and no options. This is the first transcatheter procedure, to our knowledge, to deliver standard pledgeted sutures to repair cardiac pathology.
Collapse
Affiliation(s)
- Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Adam B. Greenbaum
- Center for Structural Heart Disease, Division of Cardiology, Henry Ford Health System, Detroit, Michigan, USA
| | - Vasilis C Babaliaros
- Structural Heart and Valve Center, Emory University Hospital, Atlanta, Georgia, USA
| | - Gaetano Paone
- Division of Cardiac Surgery, Henry Ford Health System, Detroit, Michigan, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Marcus Y. Chen
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Daniel A. Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
37
|
Campbell-Washburn AE, Rogers T, Stine AM, Khan JM, Ramasawmy R, Schenke WH, McGuirt DR, Mazal JR, Grant LP, Grant EK, Herzka DA, Lederman RJ. Right heart catheterization using metallic guidewires and low SAR cardiovascular magnetic resonance fluoroscopy at 1.5 Tesla: first in human experience. J Cardiovasc Magn Reson 2018; 20:41. [PMID: 29925397 PMCID: PMC6011242 DOI: 10.1186/s12968-018-0458-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 05/10/2018] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. METHODS The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. RESULTS Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. CONCLUSIONS Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035" Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. TRIAL REGISTRATION Clinicaltrials.gov NCT03152773 , registered May 15, 2017.
Collapse
Affiliation(s)
- Adrienne E. Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Annette M. Stine
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Delaney R. McGuirt
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Jonathan R. Mazal
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Laurie P. Grant
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Elena K. Grant
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Daniel A. Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| |
Collapse
|
38
|
Walker-Samuel S, Roberts TA, Ramasawmy R, Burrell JS, Johnson SP, Siow BM, Richardson S, Gonçalves MR, Pendse D, Robinson SP, Pedley RB, Lythgoe MF. Investigating Low-Velocity Fluid Flow in Tumors with Convection-MRI. Cancer Res 2018; 78:1859-1872. [PMID: 29317434 PMCID: PMC6298581 DOI: 10.1158/0008-5472.can-17-1546] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 08/18/2017] [Accepted: 01/05/2018] [Indexed: 02/06/2023]
Abstract
Several distinct fluid flow phenomena occur in solid tumors, including intravascular blood flow and interstitial convection. Interstitial fluid pressure is often raised in solid tumors, which can limit drug delivery. To probe low-velocity flow in tumors resulting from raised interstitial fluid pressure, we developed a novel MRI technique named convection-MRI, which uses a phase-contrast acquisition with a dual-inversion vascular nulling preparation to separate intra- and extravascular flow. Here, we report the results of experiments in flow phantoms, numerical simulations, and tumor xenograft models to investigate the technical feasibility of convection-MRI. We observed a significant correlation between estimates of effective fluid pressure from convection-MRI with gold-standard, invasive measurements of interstitial fluid pressure in mouse models of human colorectal carcinoma. Our results show how convection-MRI can provide insights into the growth and responsiveness to vascular-targeting therapy in colorectal cancers.Significance: A noninvasive method for measuring low-velocity fluid flow caused by raised fluid pressure can be used to assess changes caused by therapy. Cancer Res; 78(7); 1859-72. ©2018 AACR.
Collapse
Affiliation(s)
- Simon Walker-Samuel
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK.
| | - Thomas A Roberts
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK
| | - Rajiv Ramasawmy
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK
| | - Jake S Burrell
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, Sutton, Surrey, UK
| | | | - Bernard M Siow
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK
| | - Simon Richardson
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK
| | - Miguel R Gonçalves
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK
| | | | - Simon P Robinson
- Division of Radiotherapy and Imaging, The Institute of Cancer Research, Sutton, Surrey, UK
| | | | - Mark F Lythgoe
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, UK
| |
Collapse
|
39
|
|
40
|
Rogers T, Ratnayaka K, Khan JM, Stine A, Schenke WH, Grant LP, Mazal JR, Grant EK, Campbell-Washburn A, Hansen MS, Ramasawmy R, Herzka DA, Xue H, Kellman P, Faranesh AZ, Lederman RJ. CMR fluoroscopy right heart catheterization for cardiac output and pulmonary vascular resistance: results in 102 patients. J Cardiovasc Magn Reson 2017; 19:54. [PMID: 28750642 PMCID: PMC5530573 DOI: 10.1186/s12968-017-0366-2] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Accepted: 06/21/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. METHODS One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RESULTS RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement -38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was -0.02 WU.m2 with limits of agreement -2.6 and 2.5 WU.m2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CONCLUSIONS CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. TRIAL REGISTRATION Clinicaltrials.gov NCT01287026 , registered January 25, 2011.
Collapse
Affiliation(s)
- Toby Rogers
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Kanishka Ratnayaka
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
- Department of Cardiology, Rady Children’s Hospital, San Diego, CA USA
| | - Jaffar M. Khan
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Annette Stine
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - William H. Schenke
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Laurie P. Grant
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Jonathan R. Mazal
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Elena K. Grant
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
- Department of Cardiology, Children’s National Medical Center, Washington, DC USA
| | - Adrienne Campbell-Washburn
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Michael S. Hansen
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Rajiv Ramasawmy
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Daniel A. Herzka
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Hui Xue
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Peter Kellman
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Anthony Z. Faranesh
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
| | - Robert J. Lederman
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD USA
- Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD 20892-1538 USA
| |
Collapse
|
41
|
Gonçalves MR, Johnson SP, Ramasawmy R, Lythgoe MF, Pedley RB, Walker-Samuel S. The effect of imatinib therapy on tumour cycling hypoxia, tissue oxygenation and vascular reactivity. Wellcome Open Res 2017. [DOI: 10.12688/wellcomeopenres.11715.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Abstract
Background: Several biomedical imaging techniques have recently been developed to probe hypoxia in tumours, including oxygen-enhanced (OE) and blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI). These techniques have strong potential for measuring both chronic and transient (cycling) changes in hypoxia, and to assess response to vascular-targeting therapies in the clinic. Methods: In this study, we investigated the use of BOLD and OE-MRI to assess changes in cycling hypoxia, tissue oxygenation and vascular reactivity to hyperoxic gas challenges, in mouse models of colorectal therapy, following treatment with the PDGF-receptor inhibitor, imatinib mesylate (Glivec). Results: Whilst no changes were observed in imaging biomarkers of cycling hypoxia (from BOLD) or chronic hypoxia (from OE-MRI), the BOLD response to carbogen-breathing became significantly more positive in some tumour regions and more negative in other regions, thereby increasing overall heterogeneity. Conclusions: Imatinib did not affect the magnitude of cycling hypoxia or OE-MRI signal, but increased the heterogeneity of the spatial distribution of BOLD MRI changes in response to gas challenges.
Collapse
|
42
|
Gonçalves MR, Peter Johnson S, Ramasawmy R, Barbara Pedley R, Lythgoe MF, Walker-Samuel S. Decomposition of spontaneous fluctuations in tumour oxygenation using BOLD MRI and independent component analysis. Br J Cancer 2016; 114:e13. [PMID: 27228297 PMCID: PMC4984470 DOI: 10.1038/bjc.2016.140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
43
|
Ramasawmy R, Johnson SP, Roberts TA, Stuckey DJ, David AL, Pedley RB, Lythgoe MF, Siow B, Walker-Samuel S. Monitoring the Growth of an Orthotopic Tumour Xenograft Model: Multi-Modal Imaging Assessment with Benchtop MRI (1T), High-Field MRI (9.4T), Ultrasound and Bioluminescence. PLoS One 2016; 11:e0156162. [PMID: 27223614 PMCID: PMC4880291 DOI: 10.1371/journal.pone.0156162] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Accepted: 05/10/2016] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Research using orthotopic and transgenic models of cancer requires imaging methods to non-invasively quantify tumour burden. As the choice of appropriate imaging modality is wide-ranging, this study aimed to compare low-field (1T) magnetic resonance imaging (MRI), a novel and relatively low-cost system, against established preclinical techniques: bioluminescence imaging (BLI), ultrasound imaging (US), and high-field (9.4T) MRI. METHODS A model of colorectal metastasis to the liver was established in eight mice, which were imaged with each modality over four weeks post-implantation. Tumour burden was assessed from manually segmented regions. RESULTS All four imaging systems provided sufficient contrast to detect tumours in all of the mice after two weeks. No significant difference was detected between tumour doubling times estimated by low-field MRI, ultrasound imaging or high-field MRI. A strong correlation was measured between high-field MRI estimates of tumour burden and all the other modalities (p < 0.001, Pearson). CONCLUSION These results suggest that both low-field MRI and ultrasound imaging are accurate modalities for characterising the growth of preclinical tumour models.
Collapse
Affiliation(s)
- Rajiv Ramasawmy
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
- UCL Cancer Institute, London, United Kingdom
| | - S. Peter Johnson
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
- UCL Cancer Institute, London, United Kingdom
| | - Thomas A. Roberts
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
| | - Daniel J. Stuckey
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
| | - Anna L. David
- UCL Institute for Women’s Health, London, United Kingdom
| | | | - Mark F. Lythgoe
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
| | - Bernard Siow
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
| | - Simon Walker-Samuel
- UCL Centre for Advanced Biomedical Imaging, Division of Medicine, London, United Kingdom
| |
Collapse
|
44
|
Johnson SP, Ramasawmy R, Campbell-Washburn AE, Wells JA, Robson M, Rajkumar V, Lythgoe MF, Pedley RB, Walker-Samuel S. Acute changes in liver tumour perfusion measured non-invasively with arterial spin labelling. Br J Cancer 2016; 114:897-904. [PMID: 27031853 PMCID: PMC4984798 DOI: 10.1038/bjc.2016.51] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Revised: 01/26/2016] [Accepted: 02/04/2016] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Non-invasive measures of tumour vascular perfusion are desirable, in order to assess response to vascular targeting (or modifying) therapies. In this study, hepatic arterial spin labelling (ASL) magnetic resonance imaging (MRI) was investigated to measure acute changes in perfusion of colorectal cancer in the liver, in response to vascular disruption therapy with OXi4503. METHODS SW1222 and LS174T tumours were established in the liver of MF1 nu/nu mice via intrasplenic injection. Perfusion and R2(*) MRI measurements were acquired with an Agilent 9.4T horizontal bore scanner, before and at 90 min after 40 mg kg(-1) OXi4503. RESULTS A significant decrease in SW1222 tumour perfusion was observed (-43±33%, P<0.005). LS174T tumours had a significantly lower baseline level of perfusion. Intrinsic susceptibility MRI showed a significant increase in R2(*) in LS174T tumours (28±25%, P<0.05). An association was found between the change in tumour perfusion and the proximity to large vessels, with pre-treatment blood flow predictive of subsequent response. Histological evaluation confirmed the onset of necrosis and evidence of heterogeneous response between tumour deposits. CONCLUSIONS Hepatic ASL-MRI can detect acute response to targeted tumour vascular disruption entirely non-invasively. Hepatic ASL of liver tumours has potential for use in a clinical setting.
Collapse
Affiliation(s)
- S Peter Johnson
- UCL Cancer Institute, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
- UCL Centre for Advanced Biomedical Imaging, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - Rajiv Ramasawmy
- UCL Cancer Institute, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
- UCL Centre for Advanced Biomedical Imaging, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - Adrienne E Campbell-Washburn
- UCL Centre for Advanced Biomedical Imaging, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA
| | - Jack A Wells
- UCL Centre for Advanced Biomedical Imaging, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - Mathew Robson
- UCL Cancer Institute, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - Vineeth Rajkumar
- UCL Cancer Institute, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - Mark F Lythgoe
- UCL Centre for Advanced Biomedical Imaging, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - R Barbara Pedley
- UCL Cancer Institute, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| | - Simon Walker-Samuel
- UCL Centre for Advanced Biomedical Imaging, University College London, Paul O'Gorman Building, 72 Huntley Street, London WC1E 6DD, UK
| |
Collapse
|
45
|
Garrido MDS, Bührer-Sékula S, Souza AB, de Oliveira GP, Antunes IA, Mendes JM, Saraceni V, Martinez-Espinosa FE, Ramasawmy R. Multidrug-resistant tuberculosis in the Amazonas State, Brazil, 2000-2011. Int J Tuberc Lung Dis 2016; 19:531-6. [PMID: 25868020 DOI: 10.5588/ijtld.14.0291] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
SETTINGS Amazonas is facing increasing challenges in tuberculosis (TB) control, with nearly 3000 cases per year, and multidrug-resistant TB (MDR-TB) may jeopardise the TB control programme. OBJECTIVE To assess the number of MDR-TB cases in the Amazonas and to improve estimates of the burden of TB. DESIGNS The Brazilian National Mandatory Disease Reporting System (SINAN) and the Brazilian Epidemiological Surveillance System of Multidrug Resistance (TBMR) were searched for MDR-TB cases in the State of Amazonas from 2000 to 2011. RESULTS Eighty-one MDR-TB cases were notified. The rates of primary MDR-TB, initial MDR-TB during the first treatment regimen and acquired MDR-TB were respectively 3.8%, 13.7% and 82.7%; 26.9% of previously treated patients had ⩾ 4 treatment cycles. The MDR-TB cases reported 263 contacts, only 35.0% of whom were examined. The cure and death rates among the 81 patients with MDR-TB were respectively 45.7% and 25.9%. CONCLUSIONS The number of MDR-TB cases seems incompatible with the high TB prevalence in the Amazonas. Most patients were unaware of contact with TB patients. TB is endemic in the Amazonas. This highlights the need for improving resistance investigation among all TB cases.
Collapse
Affiliation(s)
- M da S Garrido
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil; Fundação de Vigilância em Saúde do Amazonas, Manaus, Amazonas, Brazil; Secretaria Municipal de Saúde de Manaus, Manaus, Amazonas, Brazil
| | - S Bührer-Sékula
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil; Instituto de Patologia e Saúde Pública, Universidade Federal de Goiás, Goiânia, Goiás, Brazil
| | - A B Souza
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil
| | - G P de Oliveira
- Programa Nacional de Tuberculose, Ministério da Saúde, Brasília, Brazil
| | - I A Antunes
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil, Centro de Referência para Tuberculose Cardoso Fontes, Manaus, Amazonas, Brazil
| | - J M Mendes
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil; Centro de Referência para Tuberculose Cardoso Fontes, Manaus, Amazonas, Brazil
| | - V Saraceni
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil; Secretaria Municipal de Saúde do Rio de Janeiro, Rio de Janeiro, Rio de Janeiro, Brazil
| | - F E Martinez-Espinosa
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil; Instituto Leônidas e Maria Deane, Fundação Oswaldo Cruz Amazônia, Manaus, Amazonas, Brazil
| | - R Ramasawmy
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Universidade do Estado do Amazonas, Manaus, Amazonas, Brazil; Universidade Nilton Lins, Manaus, Amazonas, Brazil; Programa de Pós-graduação em Imunologia Básica e Aplicada, Universidade Federal de Amazonas, Manaus, Amazonas, Brazil
| |
Collapse
|
46
|
Gonçalves MR, Johnson SP, Ramasawmy R, Pedley RB, Lythgoe MF, Walker-Samuel S. Decomposition of spontaneous fluctuations in tumour oxygenation using BOLD MRI and independent component analysis. Br J Cancer 2015; 113:1168-77. [PMID: 26484634 PMCID: PMC4647875 DOI: 10.1038/bjc.2015.270] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Revised: 05/26/2015] [Accepted: 06/29/2015] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Solid tumours can undergo cycles of hypoxia, followed by reoxygenation, which can have significant implications for the success of anticancer therapies. A need therefore exists to develop methods to aid its detection and to further characterise its biological basis. We present here a novel method for decomposing systemic and tumour-specific contributions to fluctuations in tumour deoxyhaemoglobin concentration, based on magnetic resonance imaging measurements. METHODS Fluctuations in deoxyhaemoglobin concentration in two tumour xenograft models of colorectal carcinoma were decomposed into distinct contributions using independent component analysis. These components were then correlated with systemic pulse oximetry measurements to assess the influence of systemic variations in blood oxygenation in tumours, compared with those that arise within the tumour itself (tumour-specific). Immunohistochemical staining was used to assess the physiological basis of each source of fluctuation. RESULTS Systemic fluctuations in blood oxygenation were found to contribute to cycling hypoxia in tumours, but tumour-specific fluctuations were also evident. Moreover, the size of the tumours was found to influence the degree of systemic, but not tumour-specific, oscillations. The degree of vessel maturation was related to the amplitude of tumour-specific, but not systemic, oscillations. CONCLUSIONS Our results provide further insights into the complexity of spontaneous fluctuations in tumour oxygenation and its relationship with tumour pathophysiology. These observations could be used to develop improved drug delivery strategies.
Collapse
Affiliation(s)
- Miguel R Gonçalves
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London WC1E 6DD, UK
| | - S Peter Johnson
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London WC1E 6DD, UK
- Cancer Institute, University College London, London WC1E 6DD, UK
| | - Rajiv Ramasawmy
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London WC1E 6DD, UK
| | - R Barbara Pedley
- Cancer Institute, University College London, London WC1E 6DD, UK
| | - Mark F Lythgoe
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London WC1E 6DD, UK
| | - Simon Walker-Samuel
- Centre for Advanced Biomedical Imaging, Division of Medicine, University College London, London WC1E 6DD, UK
| |
Collapse
|
47
|
de Araujo FJ, Mesquita TG, da Silva LDO, de Almeida SA, de S Vital W, Chrusciak-Talhari A, de O Guerra JA, Talhari S, Ramasawmy R. Functional variations in MBL2 gene are associated with cutaneous leishmaniasis in the Amazonas state of Brazil. Genes Immun 2015; 16:284-8. [PMID: 25764115 DOI: 10.1038/gene.2015.6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 12/19/2014] [Accepted: 01/05/2015] [Indexed: 01/01/2023]
Abstract
Functional variations in the mannose-binding lectin (MBL2) gene causing low levels of serum MBL are associated with susceptibility to numerous infectious diseases. We investigated whether there is genetic association of MBL2 variant alleles with cutaneous leishmaniasis (CL) caused by Leishmania guyanensis. We used PCR-restriction fragment length polymorphism to genotype six MBL2 variants, three in the promoter region and three in the exon 1. An association was noted between the single nucleotide polymorphism -221X/Y of the MBL2 gene and CL (P=2.9 × 10(-6); odds ratio (OR)=1.9 (1.4-2.5) consistent with the hypothesis that the -221X allele confers high risk to development of CL among L. guyanensis-infected individuals. Furthermore, L. guyanensis-infected individuals bearing the codon 57 allele C had a higher risk of developing CL (P=5 × 10(-5); OR=1.9 (1.4-2.6)). The low MBL expressor haplotype LXPB was also associated to CL (P=6 × 10(-4)). This study raises the possibility that functional polymorphisms in MBL2 gene play a role in clinical outcome of Leishmania infection.
Collapse
Affiliation(s)
- F J de Araujo
- Faculdade de Medicina, Universidade Nilton Lins, Av. Prof Nilton Lins, Manaus, Brazil
| | - T G Mesquita
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Brazil
| | - L D O da Silva
- Faculdade de Medicina, Universidade Nilton Lins, Av. Prof Nilton Lins, Manaus, Brazil
| | - S A de Almeida
- Faculdade de Medicina, Universidade Nilton Lins, Av. Prof Nilton Lins, Manaus, Brazil
| | - W de S Vital
- Faculdade de Medicina, Universidade Nilton Lins, Av. Prof Nilton Lins, Manaus, Brazil
| | | | - J A de O Guerra
- Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Brazil
| | - S Talhari
- Faculdade de Medicina, Universidade Nilton Lins, Av. Prof Nilton Lins, Manaus, Brazil
| | - R Ramasawmy
- 1] Faculdade de Medicina, Universidade Nilton Lins, Av. Prof Nilton Lins, Manaus, Brazil [2] Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Brazil
| |
Collapse
|
48
|
Ramasawmy R, Campbell-Washburn AE, Wells JA, Johnson SP, Pedley RB, Walker-Samuel S, Lythgoe MF. Hepatic arterial spin labelling MRI: an initial evaluation in mice. NMR Biomed 2015; 28:272-80. [PMID: 25522098 PMCID: PMC4670473 DOI: 10.1002/nbm.3251] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 10/09/2014] [Accepted: 11/26/2014] [Indexed: 05/20/2023]
Abstract
The development of strategies to combat hepatic disease and augment tissue regeneration has created a need for methods to assess regional liver function. Liver perfusion imaging has the potential to fulfil this need, across a range of hepatic diseases, alongside the assessment of therapeutic response. In this study, the feasibility of hepatic arterial spin labelling (HASL) was assessed for the first time in mice at 9.4 T, its variability and repeatability were evaluated, and it was applied to a model of colorectal liver metastasis. Data were acquired using flow-sensitive alternating inversion recovery-arterial spin labelling (FAIR-ASL) with a Look-Locker readout, and analysed using retrospective respiratory gating and a T1 -based quantification. This study shows that preclinical HASL is feasible and exhibits good repeatability and reproducibility. Mean estimated liver perfusion was 2.2 ± 0.8 mL/g/min (mean ± standard error, n = 10), which agrees well with previous measurements using invasive approaches. Estimates of the variation gave a within-session coefficient of variation (CVWS) of 7%, a between-session coefficient of variation (CVBS) of 9% and a between-animal coefficient of variation (CVA) of 15%. The within-session Bland-Altman repeatability coefficient (RCWS) was 18% and the between-session repeatability coefficient (RCBS) was 29%. Finally, the HASL method was applied to a mouse model of liver metastasis, in which significantly lower mean perfusion (1.1 ± 0.5 mL/g/min, n = 6) was measured within the tumours, as seen by fluorescence histology. These data indicate that precise and accurate liver perfusion estimates can be achieved using ASL techniques, and provide a platform for future studies investigating hepatic perfusion in mouse models of disease.
Collapse
Affiliation(s)
- R Ramasawmy
- UCL Centre for Advanced Biomedical ImagingPaul O'Gorman Building, London, UK
- UCL Cancer InstitutePaul O'Gorman Building, London, UK
| | | | - J A Wells
- UCL Centre for Advanced Biomedical ImagingPaul O'Gorman Building, London, UK
| | - S P Johnson
- UCL Centre for Advanced Biomedical ImagingPaul O'Gorman Building, London, UK
- UCL Cancer InstitutePaul O'Gorman Building, London, UK
| | - R B Pedley
- UCL Cancer InstitutePaul O'Gorman Building, London, UK
| | - S Walker-Samuel
- UCL Centre for Advanced Biomedical ImagingPaul O'Gorman Building, London, UK
| | - M F Lythgoe
- UCL Centre for Advanced Biomedical ImagingPaul O'Gorman Building, London, UK
| |
Collapse
|
49
|
Silva GAV, Ramasawmy R, Boechat AL, Morais AC, Carvalho BKS, Sousa KBA, Souza VC, Cunha MGS, Barletta-Naveca RH, Santos MP, Naveca FG. Association of TNF -1031 C/C as a potential protection marker for leprosy development in Amazonas state patients, Brazil. Hum Immunol 2015; 76:137-41. [PMID: 25636570 DOI: 10.1016/j.humimm.2015.01.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2014] [Revised: 12/26/2014] [Accepted: 01/14/2015] [Indexed: 12/30/2022]
Abstract
Polymorphisms present in the TNF promoter region has shown to influence the gene transcription. Leprosy displays different clinical manifestations according to the immune responses of the individual infected with Mycobacterium leprae. In this study, we evaluated the single nucleotide polymorphisms (SNPs) -238 G/A (rs361525), -308 G/A (rs1800629), -857 C/T (rs1799724), -863 A/C (rs1800630) and -1031 T/C (rs1799964) in the promoter region of the TNF to see whether these SNPs influence host-susceptibility to leprosy and the different clinical manifestation. Nucleotide sequencing was performed with DNA samples from 108 leprosy patients and 253 control subjects. An association between -1031 C/C genotype and protection from leprosy was observed when leprosy patients were compared to controls (OR 0.11; 95% CI=0.01-0.82; p=0.012). The -857 C/T genotype may be associated with susceptibility to leprosy (OR=1.81; 95% CI=1.09-3.00; p=0.028). Similar genotype and allele frequencies for the SNPs -308 G/A and -238 G/A were observed between leprosy patients and control subjects. Altogether, TNF polymorphisms in the promoter region may be predictive of leprosy outcome.
Collapse
Affiliation(s)
- G A V Silva
- Instituto Leônidas e Maria Deane, FIOCRUZ Amazônia, Manaus, Amazonas, Brazil.
| | - R Ramasawmy
- Fundação de Medicina Tropical Doutor Heitor Vieira Dourado, Manaus, Amazonas, Brazil; Faculdade de Medicina, Universidade Nilton Lins, Manaus, Amazonas, Brazil
| | - A L Boechat
- Laboratório de Imunologia, Departamento de Parasitologia, Instituto de Ciências Biológicas, Universidade Federal do Amazonas, Manaus, Brazil
| | - A C Morais
- Instituto Leônidas e Maria Deane, FIOCRUZ Amazônia, Manaus, Amazonas, Brazil
| | - B K S Carvalho
- Instituto Leônidas e Maria Deane, FIOCRUZ Amazônia, Manaus, Amazonas, Brazil
| | - K B A Sousa
- Instituto Leônidas e Maria Deane, FIOCRUZ Amazônia, Manaus, Amazonas, Brazil
| | - V C Souza
- Instituto Leônidas e Maria Deane, FIOCRUZ Amazônia, Manaus, Amazonas, Brazil
| | - M G S Cunha
- Fundação de Dermatologia e Venereologia Alfredo da Matta, Manaus, Amazonas, Brazil
| | - R H Barletta-Naveca
- Laboratório de Micobacteriologia, Instituto Nacional de Pesquisas da Amazônia, Manaus, Amazonas, Brazil
| | - M P Santos
- Laboratório de Micobacteriologia, Instituto Nacional de Pesquisas da Amazônia, Manaus, Amazonas, Brazil
| | - F G Naveca
- Instituto Leônidas e Maria Deane, FIOCRUZ Amazônia, Manaus, Amazonas, Brazil
| |
Collapse
|
50
|
da Silva Garrido M, Ramasawmy R, Perez-Porcuna TM, Zaranza E, Chrusciak Talhari A, Martinez-Espinosa FE, Bührer-Sékula S. Primary drug resistance among pulmonary treatment-naïve tuberculosis patients in Amazonas State, Brazil. Int J Tuberc Lung Dis 2015; 18:559-63. [PMID: 24903793 DOI: 10.5588/ijtld.13.0191] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Multidrug-resistant tuberculosis (MDR-TB) is the main indicator of previous treatment in tuberculosis (TB) patients. MDR-TB among treatment-naïve patients indicates infection with drug-resistant Mycobacterium tuberculosis strains, and such cases are considered primary drug-resistant cases. OBJECTIVE To estimate the prevalence of drug resistance in pulmonary TB (PTB) treatment-naïve patients and to identify the socio-demographic and clinical characteristics of the resistant population. METHODS A total of 205 treatment-naïve PTB patients from Manaus, Amazonas State, Brazil, were enrolled. Drug susceptibility testing (DST) was performed on all positive mycobacterial cultures using the 1% proportion method. RESULTS Positive M. tuberculosis cultures were obtained from only 175 patients for DST. The prevalence of primary MDR-TB was 1.7% (3/175); 14.3% (25/175) of the cultures presented resistance to at least one of the drugs. Resistance to streptomycin, isoniazid, rifampicin and ethambutol was respectively 8.6%, 6.9%, 3.4% and 2.3%. An association between TB patients with resistance to more than one drug and known previous household contact with a TB patient was observed (P= 0.008, OR 6.7, 95%CI 1.2-67.3). CONCLUSIONS Although the prevalence of primary MDR-TB currently is relatively low, it may become a major public health problem if tailored treatment is not provided, as resistance to more than one drug is significantly associated with household contact.
Collapse
Affiliation(s)
- M da Silva Garrido
- Universidade do Estado do Amazonas/Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, Brazil
| | - R Ramasawmy
- Universidade do Estado do Amazonas/Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, Brazil
| | - T M Perez-Porcuna
- Universidade do Estado do Amazonas/Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, Brazil
| | - E Zaranza
- Laboratório Central de Saúde Pública do Amazonas, Manaus, Amazonas, Brazil
| | - A Chrusciak Talhari
- Universidade do Estado do Amazonas/Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, Brazil
| | - F E Martinez-Espinosa
- Universidade do Estado do Amazonas/Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, Brazil
| | - S Bührer-Sékula
- Universidade do Estado do Amazonas/Fundação de Medicina Tropical Dr Heitor Vieira Dourado, Manaus, Amazonas, Brazil
| |
Collapse
|