1
|
Bucciarelli A, Mantegazza A, Haeberlin A, Obrist D. Relation between hematocrit partitioning and red blood cell lingering in a microfluidic network. Biophys J 2024; 123:3355-3365. [PMID: 39104120 PMCID: PMC11480766 DOI: 10.1016/j.bpj.2024.07.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 07/05/2024] [Accepted: 07/31/2024] [Indexed: 08/07/2024] Open
Abstract
Despite increased interest in the effect of lingering red blood cells (LRBCs) on the heterogeneous hematocrit distribution in the microcirculation, quantitative data on LRBCs before and after the lingering event are still limited. The aim of the study was to investigate the relation between red blood cell (RBC) lingering and hematocrit partitioning in a microfluidic model of a microvascular bifurcation in the limit of low hematocrit conditions (tube hematocrit <10%). To this end, the classification of LRBCs was performed based on timing, position, and velocity of the RBCs. The investigation provided statistical information on the velocity, shape, and orientation of LRBCs as well as on their lateral distribution in the parent and daughter vessels. LRBCs traveled predominantly close to the centerline of the parent vessel, but they marginated close to the distal wall in the daughter vessels. Differently than the RBC flow observed in the smallest vessels, no influence of lingering events on the local hematocrit partitioning was observed in our experiments. However, importantly, we found that LRBCs flowing in the daughter vessel after lingering may be connected to reverse hematocrit partitioning in downstream bifurcations by influencing the skewness of the hematocrit distribution in the daughter vessel, which relates to the so-called network history effect.
Collapse
Affiliation(s)
- Aurelia Bucciarelli
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
| | - Alberto Mantegazza
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Andreas Haeberlin
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland; Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Dominik Obrist
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Cutuli E, Sanalitro D, Stella G, Saitta L, Bucolo M. A 3D-Printed Micro-Optofluidic Chamber for Fluid Characterization and Microparticle Velocity Detection. MICROMACHINES 2023; 14:2115. [PMID: 38004972 PMCID: PMC10673365 DOI: 10.3390/mi14112115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 10/30/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023]
Abstract
This work proposes a multi-objective polydimethylsiloxane (PDMS) micro-optofluidic (MoF) device suitably designed and manufactured through a 3D-printed-based master-slave approach. It exploits optical detection techniques to characterize immiscible fluids or microparticles in suspension inside a compartment specifically designed at the core of the device referred to as the MoF chamber. In addition, we show our novel, fast, and cost-effective methodology, dual-slit particle signal velocimetry (DPSV), for fluids and microparticle velocity detection. Different from the standard state-of-the-art approaches, the methodology focuses on signal processing rather than image processing. This alternative has several advantages, including the ability to circumvent the requirement of complex and extensive setups and cost reduction. Additionally, its rapid processing speed allows for real-time sample manipulations in ongoing image-based analyses. For our specific design, optical signals have been detected from the micro-optics components placed in two slots designed ad hoc in the device. To show the devices' multipurpose capabilities, the device has been tested with fluids of various colors and densities and the inclusion of synthetic microparticles. Additionally, several experiments have been conducted to prove the effectiveness of the DPSV approach in estimating microparticle velocities. A digital particle image velocimetry (DPIV)-based approach has been used as a baseline against which the outcomes of our methods have been evaluated. The combination of the suitability of the micro-optical components for integration, along with the MoF chamber device and the DPSV approach, demonstrates a proof of concept towards the challenge of real-time total-on-chip analysis.
Collapse
Affiliation(s)
- Emanuela Cutuli
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| | - Dario Sanalitro
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| | - Giovanna Stella
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| | - Lorena Saitta
- Department of Civil Engineering and Architecture, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy;
| | - Maide Bucolo
- Department of Electrical Electronic and Computer Science Engineering, University of Catania, Via Santa Sofia 64, 95125 Catania, Italy; (D.S.); (G.S.); (M.B.)
| |
Collapse
|
3
|
Merlo A, Losserand S, Yaya F, Connes P, Faivre M, Lorthois S, Minetti C, Nader E, Podgorski T, Renoux C, Coupier G, Franceschini E. Influence of storage and buffer composition on the mechanical behavior of flowing red blood cells. Biophys J 2023; 122:360-373. [PMID: 36476993 PMCID: PMC9892622 DOI: 10.1016/j.bpj.2022.12.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 10/17/2022] [Accepted: 12/01/2022] [Indexed: 12/12/2022] Open
Abstract
On-chip study of blood flow has emerged as a powerful tool to assess the contribution of each component of blood to its overall function. Blood has indeed many functions, from gas and nutrient transport to immune response and thermal regulation. Red blood cells play a central role therein, in particular through their specific mechanical properties, which directly influence pressure regulation, oxygen perfusion, or platelet and white cell segregation toward endothelial walls. As the bloom of in-vitro studies has led to the apparition of various storage and sample preparation protocols, we address the question of the robustness of the results involving cell mechanical behavior against this diversity. The effects of three conservation media (EDTA, citrate, and glucose-albumin-sodium-phosphate) and storage time on the red blood cell mechanical behavior are assessed under different flow conditions: cell deformability by ektacytometry, shape recovery of cells flowing out of a microfluidic constriction, and cell-flipping dynamics under shear flow. The impact of buffer solutions (phosphate-buffered saline and density-matched suspension using iodixanol/Optiprep) are also studied by investigating individual cell-flipping dynamics, relative viscosity of cell suspensions, and cell structuration under Poiseuille flow. Our results reveal that storing blood samples up to 7 days after withdrawal and suspending them in adequate density-matched buffer solutions has, in most experiments, a moderate effect on the overall mechanical response, with a possible rapid evolution in the first 3 days after sample collection.
Collapse
Affiliation(s)
- Adlan Merlo
- GDR MECABIO, France; Institut de Mécanique des Fluides de Toulouse (IMFT), Université de Toulouse, CNRS, Toulouse, France; Biomechanics and Bioengineering Laboratory (UMR 7338), Université de Technologie de Compiègne - CNRS, Compiègne, France
| | - Sylvain Losserand
- GDR MECABIO, France; Université Grenoble Alpes, CNRS, LIPhy, Grenoble, France
| | - François Yaya
- GDR MECABIO, France; Université Grenoble Alpes, CNRS, LIPhy, Grenoble, France
| | - Philippe Connes
- GDR MECABIO, France; Team 'Vascular Biology and Red Blood Cell', Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM) EA7424, Université Claude Bernard Lyon 1, Université de Lyon, Villeurbanne, France; Laboratoire d'Excellence du Globule Rouge (Labex GR-Ex), PRES Sorbonne, Paris, France
| | - Magalie Faivre
- GDR MECABIO, France; University Lyon, CNRS, INSA Lyon, Ecole Centrale de Lyon, Université Claude Bernard Lyon 1, CPE Lyon, INL, UMR5270, Villeurbanne, France
| | - Sylvie Lorthois
- GDR MECABIO, France; Institut de Mécanique des Fluides de Toulouse (IMFT), Université de Toulouse, CNRS, Toulouse, France
| | - Christophe Minetti
- Aero Thermo Mechanics CP 165/43, Université libre de Bruxelles, Brussels, Belgium
| | - Elie Nader
- GDR MECABIO, France; Team 'Vascular Biology and Red Blood Cell', Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM) EA7424, Université Claude Bernard Lyon 1, Université de Lyon, Villeurbanne, France; Laboratoire d'Excellence du Globule Rouge (Labex GR-Ex), PRES Sorbonne, Paris, France
| | - Thomas Podgorski
- GDR MECABIO, France; Université Grenoble Alpes, CNRS, LIPhy, Grenoble, France; Université Grenoble Alpes, CNRS, Grenoble INP, LRP, Grenoble, France
| | - Céline Renoux
- GDR MECABIO, France; Team 'Vascular Biology and Red Blood Cell', Laboratoire Interuniversitaire de Biologie de la Motricité (LIBM) EA7424, Université Claude Bernard Lyon 1, Université de Lyon, Villeurbanne, France; Laboratoire d'Excellence du Globule Rouge (Labex GR-Ex), PRES Sorbonne, Paris, France; Service de biochimie et biologie moléculaire, Hospices Civils de Lyon, Lyon, France
| | - Gwennou Coupier
- GDR MECABIO, France; Université Grenoble Alpes, CNRS, LIPhy, Grenoble, France.
| | - Emilie Franceschini
- GDR MECABIO, France; Aix-Marseille University, CNRS, Centrale Marseille, LMA, Turing Center for Living Systems, Marseille, France.
| |
Collapse
|
4
|
Le AV, Fenech M. Image-Based Experimental Measurement Techniques to Characterize Velocity Fields in Blood Microflows. Front Physiol 2022; 13:886675. [PMID: 35574441 PMCID: PMC9099138 DOI: 10.3389/fphys.2022.886675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 04/04/2022] [Indexed: 11/13/2022] Open
Abstract
Predicting blood microflow in both simple and complex geometries is challenging because of the composition and behavior of the blood at microscale. However, characterization of the velocity in microchannels is the key for gaining insights into cellular interactions at the microscale, mechanisms of diseases, and efficacy of therapeutic solutions. Image-based measurement techniques are a subset of methods for measuring the local flow velocity that typically utilize tracer particles for flow visualization. In the most basic form, a high-speed camera and microscope setup are the only requirements for data acquisition; however, the development of image processing algorithms and equipment has made current image-based techniques more sophisticated. This mini review aims to provide a succinct and accessible overview of image-based experimental measurement techniques to characterize the velocity field of blood microflow. The following techniques are introduced: cell tracking velocimetry, kymographs, micro-particle velocimetry, and dual-slit photometry as entry techniques for measuring various velocity fields either in vivo or in vitro.
Collapse
Affiliation(s)
- Andy Vinh Le
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON, Canada
- Centre de Biochimie Structurale, CNRS UMR 5048—INSERM UMR 1054, University of Montpellier, Montpellier, France
| | - Marianne Fenech
- Department of Mechanical Engineering, University of Ottawa, Ottawa, ON, Canada
- *Correspondence: Marianne Fenech,
| |
Collapse
|
5
|
Merlo A, Berg M, Duru P, Risso F, Davit Y, Lorthois S. A few upstream bifurcations drive the spatial distribution of red blood cells in model microfluidic networks. SOFT MATTER 2022; 18:1463-1478. [PMID: 35088062 DOI: 10.1039/d1sm01141c] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The physics of blood flow in small vessel networks is dominated by the interactions between Red Blood Cells (RBCs), plasma and blood vessel walls. The resulting couplings between the microvessel network architecture and the heterogeneous distribution of RBCs at network-scale are still poorly understood. The main goal of this paper is to elucidate how a local effect, such as RBC partitioning at individual bifurcations, interacts with the global structure of the flow field to induce specific preferential locations of RBCs in model microfluidic networks. First, using experimental results, we demonstrate that persistent perturbations to the established hematocrit profile after diverging bifurcations may bias RBC partitioning at the next bifurcations. By performing a sensitivity analysis based upon network models of RBC flow, we show that these perturbations may propagate from bifurcation to bifurcation, leading to an outsized impact of a few crucial upstream bifurcations on the distribution of RBCs at network-scale. Based on measured hematocrit profiles, we further construct a modified RBC partitioning model that accounts for the incomplete relaxation of RBCs at these bifurcations. This model allows us to explain how the flow field results in a single pattern of RBC preferential location in some networks, while it leads to the emergence of two different patterns of RBC preferential location in others. Our findings have important implications in understanding and modeling blood flow in physiological and pathological conditions.
Collapse
Affiliation(s)
- Adlan Merlo
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France.
| | - Maxime Berg
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France.
| | - Paul Duru
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France.
| | - Frédéric Risso
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France.
| | - Yohan Davit
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France.
| | - Sylvie Lorthois
- Institut de Mécanique des Fluides de Toulouse, IMFT, Université de Toulouse, CNRS, Toulouse, France.
| |
Collapse
|
6
|
Schöps M, Clauser JC, Menne MF, Faßbänder D, Schmitz-Rode T, Steinseifer U, Arens J. Ghost Cells for Mechanical Circulatory Support In Vitro Testing: A Novel Large Volume Production. Biotechnol J 2020; 15:e1900239. [PMID: 31904165 DOI: 10.1002/biot.201900239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 12/10/2019] [Indexed: 11/09/2022]
Abstract
The aim of this work is to establish a large volume batch production system to produce sufficient volumes of ghost cells to facilitate hemolysis testing of mechanical circulatory support devices. A volume of more than 405 mL with a hematocrit of at least 28% is required to perform in vitro hemolysis testing of mechanical circulatory support devices according to international standards. The established ghost cell production method performed at the institute is limited to 3.1 mL of concentrated cells, that is, cells with 100% hematocrit, due to predominantly manual process steps. Through semi-automation of the existing method by using the large volume batch production system, productivity is increased 60-fold to 188 mL while almost doubling process efficiency to 23.5%. Time-consuming manual work such as pipetting is now supported by sensor-based process engineering. With the help of the large volume batch production system, the objective of producing large quantities of ghost cells is successfully achieved. Thus, this work lays the foundation for spatially resolved hemolysis evaluation of mechanical circulatory support devices in combination with the small-scale fluorescent hemolysis detection method.
Collapse
Affiliation(s)
- Malte Schöps
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Johanna C Clauser
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Matthias F Menne
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Dennis Faßbänder
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany.,Department of Mechanical and Aerospace Engineering, Monash Institute of Medical Engineering, Monash University, Clayton, VIC, 3800, Melbourne, Australia
| | - Jutta Arens
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| |
Collapse
|
7
|
Losserand S, Coupier G, Podgorski T. Migration velocity of red blood cells in microchannels. Microvasc Res 2019; 124:30-36. [PMID: 30831125 DOI: 10.1016/j.mvr.2019.02.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 02/18/2019] [Accepted: 02/18/2019] [Indexed: 11/25/2022]
Abstract
The lateral migration of red blood cells (RBCs) in confined channel flows is an important ingredient of microcirculatory hydrodynamics and is involved in the development of a cell free layer near vessel walls and influences the distribution of RBCs in networks. It is also relevant to a number of lab-on-chip applications. This migration is a consequence of their deformability and is due to the combined effects of hydrodynamic wall repulsion and the curvature of the fluid velocity profile. We performed microfluidic experiments with dilute suspensions of RBCs in which the trajectories and migration away from the channel wall are analyzed to extract the mean behavior, from which we propose a generic scaling law for the transverse migration velocity valid in a whole range of parameters relevant to microcirculatory and practical situations. Experiments with RBCs of different mechanical properties (separated by density gradient sedimentation or fixed with glutaraldehyde) show the influence of this parameter which can induce significant dispersion of the trajectories.
Collapse
Affiliation(s)
| | - Gwennou Coupier
- Université Grenoble Alpes, CNRS, LIPhy, Grenoble F-38000, France
| | - Thomas Podgorski
- Université Grenoble Alpes, CNRS, LIPhy, Grenoble F-38000, France
| |
Collapse
|
8
|
Cairone F, Ortiz D, Cabrales PJ, Intaglietta M, Bucolo M. Emergent behaviors in RBCs flows in micro-channels using digital particle image velocimetry. Microvasc Res 2017; 116:77-86. [PMID: 28918110 DOI: 10.1016/j.mvr.2017.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2017] [Revised: 08/08/2017] [Accepted: 09/12/2017] [Indexed: 01/22/2023]
Abstract
The key points in the design of microfluidic Lab-On-a-Chips for blood tests are the simplicity of the microfluidic chip geometry, the portability of the monitoring system and the ease on-chip integration of the data analysis procedure. The majority of those, recently designed, have been used for blood separation, however their introduction, also, for pathological conditions diagnosis would be important in different biomedical contexts. To overcome this lack is necessary to establish the relation between the RBCs flow and blood viscosity changes in micro-vessels. For that, the development of methods to analyze the dynamics of the RBCs flows in networks of micro-channels becomes essential in the study of RBCs flows in micro-vascular networks. A simplification in the experimental set-up and in the approach for the data collection and analysis could contribute significantly to understand the relation between the blood non-Newtonian properties and the emergent behaviors in collective RBCs flows. In this paper, we have investigated the collective behaviors of RBCs in a micro-channel in unsteady conditions, using a simplified monitoring set-up and implementing a 2D image processing procedure based on the digital particle image velocimetry. Our experimental study consisted in the analysis of RBCs motions freely in the micro-channel and driven by an external pressure. Despite the equipment minimal complexity, the advanced signal processing method implemented has allowed a significant qualitative and quantitative classification of the RBCs behaviors and the dynamical characterization of the particles velocities along both the horizontal and vertical directions. The concurrent causes for the particles displacement as the base solution-particles interaction, particle-particle interaction, and the external force due to pressure gradient were accounted in the results interpretation. The method implemented and the results obtained represent a proof of concept toward the realization of a general-purpose microfluidic LOC device for in-vitro flow analysis of RBCs collective behaviors.
Collapse
Affiliation(s)
- F Cairone
- Department of Electrical, Electronic and Computer Science Engineering, University of Catania, Italy.
| | - D Ortiz
- Department of Bioengineering, University of California San Diego, California, USA
| | - P J Cabrales
- Department of Bioengineering, University of California San Diego, California, USA
| | - M Intaglietta
- Department of Bioengineering, University of California San Diego, California, USA
| | - M Bucolo
- Department of Electrical, Electronic and Computer Science Engineering, University of Catania, Italy
| |
Collapse
|
9
|
Zhao G, Zhang Z, Zhang Y, Chen Z, Niu D, Cao Y, He X. A microfluidic perfusion approach for on-chip characterization of the transport properties of human oocytes. LAB ON A CHIP 2017; 17:1297-1305. [PMID: 28244515 PMCID: PMC5399771 DOI: 10.1039/c6lc01532h] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Accurate characterization of the cell membrane transport properties of human oocytes is of great significance to reproductive pharmacology, fertility preservation, and assisted reproduction. However, the commonly used manual method for quantifying the transport properties is associated with uncontrolled operator-to-operator and run-to-run variability. Here, we report a novel sandwich structured microfluidic device that can be readily fabricated for characterizing oocyte membrane transport properties. Owing to its capacity for excellent control of both solution replacement and temperature in the microchannel, the temperature-dependent permeability of the oocyte membrane can be precisely characterized. Furthermore, the fertilization and developmental competence analysis post perfusion indicate that our approach does not compromise the physiological function of in vitro matured human oocytes. Collectively, we present the development of a novel sandwich structured microfluidic device based approach that allows on-chip characterization of the transport properties of human oocytes under innocuous osmotic shock or injury to the cells.
Collapse
Affiliation(s)
- Gang Zhao
- Department of Electronic Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Zhiguo Zhang
- Reproductive Medicine Center, Department of Obstetrics and Gynecology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui 230022, China
| | - Yuntian Zhang
- Department of Electronic Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Zhongrong Chen
- Department of Electronic Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Dan Niu
- Department of Electronic Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Yunxia Cao
- Reproductive Medicine Center, Department of Obstetrics and Gynecology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui 230022, China
| | - Xiaoming He
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio 43210, USA
| |
Collapse
|
10
|
Red blood cell phase separation in symmetric and asymmetric microchannel networks: effect of capillary dilation and inflow velocity. Sci Rep 2016; 6:36763. [PMID: 27857165 PMCID: PMC5114676 DOI: 10.1038/srep36763] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Accepted: 10/20/2016] [Indexed: 12/31/2022] Open
Abstract
The non-uniform partitioning or phase separation of red blood cells (RBCs) at a diverging bifurcation of a microvascular network is responsible for RBC heterogeneity within the network. The mechanisms controlling RBC heterogeneity are not yet fully understood and there is a need to improve the basic understanding of the phase separation phenomenon. In this context, in vitro experiments can fill the gap between existing in vivo and in silico models as they provide better controllability than in vivo experiments without mathematical idealizations or simplifications inherent to in silico models. In this study, we fabricated simple models of symmetric/asymmetric microvascular networks; we provided quantitative data on the RBC velocity, line density and flux in the daughter branches. In general our results confirmed the tendency of RBCs to enter the daughter branch with higher flow rate (Zweifach-Fung effect); in some cases even inversion of the Zweifach-Fung effect was observed. We showed for the first time a reduction of the Zweifach-Fung effect with increasing flow rate. Moreover capillary dilation was shown to cause an increase of RBC line density and RBC residence time within the dilated capillary underlining the possible role of pericytes in regulating the oxygen supply.
Collapse
|
11
|
Ramírez-Miquet EE, Perchoux J, Loubière K, Tronche C, Prat L, Sotolongo-Costa O. Optical Feedback Interferometry for Velocity Measurement of Parallel Liquid-Liquid Flows in a Microchannel. SENSORS 2016; 16:s16081233. [PMID: 27527178 PMCID: PMC5017398 DOI: 10.3390/s16081233] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 07/19/2016] [Accepted: 08/02/2016] [Indexed: 11/21/2022]
Abstract
Optical feedback interferometry (OFI) is a compact sensing technique with recent implementation for flow measurements in microchannels. We propose implementing OFI for the analysis at the microscale of multiphase flows starting with the case of parallel flows of two immiscible fluids. The velocity profiles in each phase were measured and the interface location estimated for several operating conditions. To the authors knowledge, this sensing technique is applied here for the first time to multiphase flows. Theoretical profiles issued from a model based on the Couette viscous flow approximation reproduce fairly well the experimental results. The sensing system and the analysis presented here provide a new tool for studying more complex interactions between immiscible fluids (such as liquid droplets flowing in a microchannel).
Collapse
Affiliation(s)
- Evelio E Ramírez-Miquet
- LAAS-CNRS, Université de Toulouse, CNRS, INP, Toulouse F-31400, France.
- Centro de Aplicaciones Tecnológicas y Desarrollo Nuclear (CEADEN), Calle 30 No. 502, Miramar, La Habana 11300, Cuba.
| | - Julien Perchoux
- LAAS-CNRS, Université de Toulouse, CNRS, INP, Toulouse F-31400, France.
| | - Karine Loubière
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, 4 allée Emile Monso, BP 84234, Toulouse F-31432, France.
| | - Clément Tronche
- LAAS-CNRS, Université de Toulouse, CNRS, INP, Toulouse F-31400, France.
| | - Laurent Prat
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, 4 allée Emile Monso, BP 84234, Toulouse F-31432, France.
| | - Oscar Sotolongo-Costa
- Instituto de Investigación en Ciencias Básicas y Aplicadas, Universidad Autónoma del Estado de Morelos, Cuernavaca 62209, Mexico.
- Cátedra de Sistemas Complejos Henri Poincaré, Universidad de La Habana, La Habana 10400, Cuba.
| |
Collapse
|
12
|
Roman S, Merlo A, Duru P, Risso F, Lorthois S. Going beyond 20 μm-sized channels for studying red blood cell phase separation in microfluidic bifurcations. BIOMICROFLUIDICS 2016; 10:034103. [PMID: 27190568 PMCID: PMC4866949 DOI: 10.1063/1.4948955] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Accepted: 04/27/2016] [Indexed: 05/13/2023]
Abstract
Despite the development of microfluidics, experimental challenges are considerable for achieving a quantitative study of phase separation, i.e., the non-proportional distribution of Red Blood Cells (RBCs) and suspending fluid, in microfluidic bifurcations with channels smaller than 20 μm. Yet, a basic understanding of phase separation in such small vessels is needed for understanding the coupling between microvascular network architecture and dynamics at larger scale. Here, we present the experimental methodologies and measurement techniques developed for that purpose for RBC concentrations (tube hematocrits) ranging between 2% and 20%. The maximal RBC velocity profile is directly measured by a temporal cross-correlation technique which enables to capture the RBC slip velocity at walls with high resolution, highlighting two different regimes (flat and more blunted ones) as a function of RBC confinement. The tube hematocrit is independently measured by a photometric technique. The RBC and suspending fluid flow rates are then deduced assuming the velocity profile of a Newtonian fluid with no slip at walls for the latter. The accuracy of this combination of techniques is demonstrated by comparison with reference measurements and verification of RBC and suspending fluid mass conservation at individual bifurcations. The present methodologies are much more accurate, with less than 15% relative errors, than the ones used in previous in vivo experiments. Their potential for studying steady state phase separation is demonstrated, highlighting an unexpected decrease of phase separation with increasing hematocrit in symmetrical, but not asymmetrical, bifurcations and providing new reference data in regimes where in vitro results were previously lacking.
Collapse
|
13
|
Roman S, Lorthois S, Duru P, Risso F. Flow of concentrated red blood cell suspensions at micro-bifurcations: an in vitro experimental study. Comput Methods Biomech Biomed Engin 2013; 16 Suppl 1:33-5. [PMID: 23923838 DOI: 10.1080/10255842.2013.815968] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- S Roman
- Institut de Mécanique des Fluides de Toulouse, UMR CNRS 5502, Toulouse, France
| | | | | | | |
Collapse
|