Sousa JM, Appel L, Engström M, Nyholm D, Ahlström H, Lubberink M. Comparison of quantitative [ 11C]PE2I brain PET studies between an integrated PET/MR and a stand-alone PET system. Phys Med 2024; 117:103185. [PMID: 38042064 DOI: 10.1016/j.ejmp.2023.103185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 11/03/2023] [Accepted: 11/20/2023] [Indexed: 12/04/2023] Open
Abstract
PET/MR systems demanded great efforts for accurate attenuation correction (AC) but differences in technology, geometry and hardware attenuation may also affect quantitative results. Dedicated PET systems using transmission-based AC are regarded as the gold standard for quantitative brain PET. The study aim was to investigate the agreement between quantitative PET outcomes from a PET/MR scanner against a stand-alone PET system. Nine patients with Parkinsonism underwent two 80-min dynamic PET scans with the dopamine transporter ligand [11C]PE2I. Images were reconstructed with resolution-matched settings using 68Ge-transmission (stand-alone PET), and zero-echo-time MR (PET/MR) scans for AC. Non-displaceable binding potential (BPND) and relative delivery (R1) were evaluated using volumes of interest and voxel-wise analysis. Correlations between systems were high (r ≥ 0.85) for both quantitative outcome parameters in all brain regions. Striatal BPND was significantly lower on PET/MR than on stand-alone PET (-7%). R1 was significantly overestimated in posterior cortical regions (9%) and underestimated in striatal (-9%) and limbic areas (-6%). The voxel-wise evaluation revealed that the MR-safe headphones caused a negative bias in both parametric BPND and R1 images. Additionally, a significant positive bias of R1 was found in the auditory cortex, most likely due to the acoustic background noise during MR imaging. The relative bias of the quantitative [11C]PE2I PET data acquired from a SIGNA PET/MR system was in the same order as the expected test-retest reproducibility of [11C]PE2I BPND and R1, compared to a stand-alone ECAT PET scanner. MR headphones and background noise are potential sources of error in functional PET/MR studies.
Collapse
Affiliation(s)
- João M Sousa
- Nuclear Medicine & PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Medical Physics, Uppsala University Hospital, Uppsala, Sweden.
| | - Lieuwe Appel
- Nuclear Medicine & PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | | | - Dag Nyholm
- Department of Neurology, Uppsala University Hospital, Uppsala, Sweden; Department of Medical Sciences, Neurology, Uppsala University, Uppsala, Sweden
| | - Håkan Ahlström
- Nuclear Medicine & PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden; Antaros Medical AB, BioVenture Hub, Mölndal, Sweden
| | - Mark Lubberink
- Nuclear Medicine & PET, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
2
|
Jonasson M, Frick A, Fazio P, Hjorth O, Danfors T, Axelsson J, Appel L, Furmark T, Varrone A, Lubberink M. Striatal dopamine transporter and receptor availability correlate with relative cerebral blood flow measured with [ 11C]PE2I, [ 18F]FE-PE2I and [ 11C]raclopride PET in healthy individuals. J Cereb Blood Flow Metab 2023; 43:1206-1215. [PMID: 36912083 PMCID: PMC10291448 DOI: 10.1177/0271678x231160881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 12/14/2022] [Accepted: 12/26/2022] [Indexed: 03/14/2023]
Abstract
The aim of this retrospective study was to investigate relationships between relative cerebral blood flow and striatal dopamine transporter and dopamine D2/3 availability in healthy subjects. The data comprised dynamic PET scans with two dopamine transporter tracers [11C]PE2I (n = 20) and [18F]FE-PE2I (n = 20) and the D2/3 tracer [11C]raclopride (n = 18). Subjects with a [11C]PE2I scan also underwent a dynamic scan with the serotonin transporter tracer [11C]DASB. Binding potential (BPND) and relative tracer delivery (R1) values were calculated on regional and voxel-level. Striatal R1 and BPND values were correlated, using either an MRI-based volume of interest (VOI) or an isocontour VOI based on the parametric BPND image. An inter-tracer comparison between [11C]PE2I BPND and [11C]DASB R1 was done on a VOI-level and simulations were performed to investigate whether the constraints of the modeling could cause correlation of the parameters. A positive association was found between BPND and R1 for all three dopamine tracers. A similar correlation was found for the inter-tracer correlation between [11C]PE2I BPND and [11C]DASB R1. Simulations showed that this relationship was not caused by cross-correlation between parameters in the kinetic model. In conclusion, these results suggest an association between resting-state striatal dopamine function and relative blood flow in healthy subjects.
Collapse
Affiliation(s)
- My Jonasson
- Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala University, Uppsala, Sweden
- Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Andreas Frick
- Department of Medical Sciences, Psychiatry, Uppsala University, Uppsala, Sweden
| | - Patrik Fazio
- Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Stockholm, Sweden
| | - Olof Hjorth
- Department of Psychology, Uppsala University, Uppsala, Sweden
| | - Torsten Danfors
- Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Jan Axelsson
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Lieuwe Appel
- Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Tomas Furmark
- Department of Psychology, Uppsala University, Uppsala, Sweden
| | - Andrea Varrone
- Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Stockholm, Sweden
| | - Mark Lubberink
- Department of Surgical Sciences, Nuclear Medicine and PET, Uppsala University, Uppsala, Sweden
- Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
3
|
Hjorth OR, Frick A, Gingnell M, Hoppe JM, Faria V, Hultberg S, Alaie I, Månsson KNT, Wahlstedt K, Jonasson M, Lubberink M, Antoni G, Fredrikson M, Furmark T. Expression and co-expression of serotonin and dopamine transporters in social anxiety disorder: a multitracer positron emission tomography study. Mol Psychiatry 2021; 26:3970-3979. [PMID: 31822819 DOI: 10.1038/s41380-019-0618-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 11/20/2019] [Accepted: 11/21/2019] [Indexed: 11/09/2022]
Abstract
Serotonin and dopamine are putatively involved in the etiology and treatment of anxiety disorders, but positron emission tomography (PET) studies probing the two neurotransmitters in the same individuals are lacking. The aim of this multitracer PET study was to evaluate the regional expression and co-expression of the transporter proteins for serotonin (SERT) and dopamine (DAT) in patients with social anxiety disorder (SAD). Voxel-wise binding potentials (BPND) for SERT and DAT were determined in 27 patients with SAD and 43 age- and sex-matched healthy controls, using the radioligands [11C]DASB (3-amino-4-(2-dimethylaminomethylphenylsulfanyl)-benzonitrile) and [11C]PE2I (N-(3-iodopro-2E-enyl)-2beta-carbomethoxy-3beta-(4'-methylphenyl)nortropane). Results showed that, within transmitter systems, SAD patients exhibited higher SERT binding in the nucleus accumbens while DAT availability in the amygdala, hippocampus, and putamen correlated positively with symptom severity. At a more lenient statistical threshold, SERT and DAT BPND were also higher in other striatal and limbic regions in patients, and correlated with symptom severity, whereas no brain region showed higher binding in healthy controls. Moreover, SERT/DAT co-expression was significantly higher in SAD patients in the amygdala, nucleus accumbens, caudate, putamen, and posterior ventral thalamus, while lower co-expression was noted in the dorsomedial thalamus. Follow-up logistic regression analysis confirmed that SAD diagnosis was significantly predicted by the statistical interaction between SERT and DAT availability, in the amygdala, putamen, and dorsomedial thalamus. Thus, SAD was associated with mainly increased expression and co-expression of the transporters for serotonin and dopamine in fear and reward-related brain regions. Resultant monoamine dysregulation may underlie SAD symptomatology and constitute a target for treatment.
Collapse
Affiliation(s)
- Olof R Hjorth
- Department of Psychology, Uppsala University, Uppsala, Sweden.
| | - Andreas Frick
- Department of Psychology, Uppsala University, Uppsala, Sweden.,The Beijer Laboratory, Department of Neuroscience, Psychiatry, Uppsala University, Uppsala, Sweden.,Department of Neuroscience, Psychiatry, Uppsala University, Uppsala, Sweden
| | - Malin Gingnell
- Department of Psychology, Uppsala University, Uppsala, Sweden.,Department of Neuroscience, Psychiatry, Uppsala University, Uppsala, Sweden
| | - Johanna M Hoppe
- Department of Psychology, Uppsala University, Uppsala, Sweden
| | - Vanda Faria
- Department of Psychology, Uppsala University, Uppsala, Sweden.,Center for Pain and the Brain, Department of Anesthesiology Perioperative and Pain Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.,Smell & Taste Clinic, Department of Otorhinolaryngology, TU Dresden, Dresden, Germany
| | - Sara Hultberg
- Department of Psychology, Uppsala University, Uppsala, Sweden
| | - Iman Alaie
- Department of Neuroscience, Child and Adolescent Psychiatry, Uppsala University, Uppsala, Sweden
| | - Kristoffer N T Månsson
- Centre for Lifespan Psychology, Max Planck Institute for Human Development, Berlin, Germany.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Max Planck UCL Centre for Computational Psychiatry and Ageing Research, Berlin, Germany
| | - Kurt Wahlstedt
- Department of Psychology, Uppsala University, Uppsala, Sweden
| | - My Jonasson
- Department of Surgical Sciences-Nuclear medicine and PET, Uppsala University, Uppsala, Sweden
| | - Mark Lubberink
- Department of Surgical Sciences-Nuclear medicine and PET, Uppsala University, Uppsala, Sweden
| | - Gunnar Antoni
- Department of Medicinal Chemistry, Uppsala University, Uppsala, Sweden
| | - Mats Fredrikson
- Department of Psychology, Uppsala University, Uppsala, Sweden.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Tomas Furmark
- Department of Psychology, Uppsala University, Uppsala, Sweden
| |
Collapse
|
4
|
Sousa JM, Appel L, Merida I, Heckemann RA, Costes N, Engström M, Papadimitriou S, Nyholm D, Ahlström H, Hammers A, Lubberink M. Accuracy and precision of zero-echo-time, single- and multi-atlas attenuation correction for dynamic [ 11C]PE2I PET-MR brain imaging. EJNMMI Phys 2020; 7:77. [PMID: 33369700 PMCID: PMC7769756 DOI: 10.1186/s40658-020-00347-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 12/09/2020] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND A valid photon attenuation correction (AC) method is instrumental for obtaining quantitatively correct PET images. Integrated PET/MR systems provide no direct information on attenuation, and novel methods for MR-based AC (MRAC) are still under investigation. Evaluations of various AC methods have mainly focused on static brain PET acquisitions. In this study, we determined the validity of three MRAC methods in a dynamic PET/MR study of the brain. METHODS Nine participants underwent dynamic brain PET/MR scanning using the dopamine transporter radioligand [11C]PE2I. Three MRAC methods were evaluated: single-atlas (Atlas), multi-atlas (MaxProb) and zero-echo-time (ZTE). The 68Ge-transmission data from a previous stand-alone PET scan was used as reference method. Parametric relative delivery (R1) images and binding potential (BPND) maps were generated using cerebellar grey matter as reference region. Evaluation was based on bias in MRAC maps, accuracy and precision of [11C]PE2I BPND and R1 estimates, and [11C]PE2I time-activity curves. BPND was examined for striatal regions and R1 in clusters of regions across the brain. RESULTS For BPND, ZTE-MRAC showed the highest accuracy (bias < 2%) in striatal regions. Atlas-MRAC exhibited a significant bias in caudate nucleus (- 12%) while MaxProb-MRAC revealed a substantial, non-significant bias in the putamen (9%). R1 estimates had a marginal bias for all MRAC methods (- 1.0-3.2%). MaxProb-MRAC showed the largest intersubject variability for both R1 and BPND. Standardized uptake values (SUV) of striatal regions displayed the strongest average bias for ZTE-MRAC (~ 10%), although constant over time and with the smallest intersubject variability. Atlas-MRAC had highest variation in bias over time (+10 to - 10%), followed by MaxProb-MRAC (+5 to - 5%), but MaxProb showed the lowest mean bias. For the cerebellum, MaxProb-MRAC showed the highest variability while bias was constant over time for Atlas- and ZTE-MRAC. CONCLUSIONS Both Maxprob- and ZTE-MRAC performed better than Atlas-MRAC when using a 68Ge transmission scan as reference method. Overall, ZTE-MRAC showed the highest precision and accuracy in outcome parameters of dynamic [11C]PE2I PET analysis with use of kinetic modelling.
Collapse
Affiliation(s)
- João M Sousa
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
| | - Lieuwe Appel
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | | | - Rolf A Heckemann
- Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | | | | | | | - Dag Nyholm
- Department of Neurology, Uppsala University Hospital, Uppsala, Sweden
- Department of Neurosciences, Uppsala University, Uppsala, Sweden
| | - Håkan Ahlström
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Alexander Hammers
- King's College London & Guy's and St Thomas' PET Centre, King's College, London, UK
| | - Mark Lubberink
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
5
|
Sousa JM, Appel L, Engström M, Papadimitriou S, Nyholm D, Larsson EM, Ahlström H, Lubberink M. Evaluation of zero-echo-time attenuation correction for integrated PET/MR brain imaging-comparison to head atlas and 68Ge-transmission-based attenuation correction. EJNMMI Phys 2018; 5:20. [PMID: 30345471 PMCID: PMC6196145 DOI: 10.1186/s40658-018-0220-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Accepted: 06/05/2018] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND MRI does not offer a direct method to obtain attenuation correction maps as its predecessors (stand-alone PET and PET/CT), and bone visualisation is particularly challenging. Recently, zero-echo-time (ZTE) was suggested for MR-based attenuation correction (AC). The aim of this work was to evaluate ZTE- and atlas-AC by comparison to 68Ge-transmission scan-based AC. Nine patients underwent brain PET/MR and stand-alone PET scanning using the dopamine transporter ligand 11C-PE2I. For each of them, two AC maps were obtained from the MR images: an atlas-based, obtained from T1-weighted LAVA-FLEX imaging with cortical bone inserted using a CT-based atlas, and an AC map generated from proton-density-weighted ZTE images. Stand-alone PET 68Ge-transmission AC map was used as gold standard. PET images were reconstructed using the three AC methods and standardised uptake value (SUV) values for the striatal, limbic and cortical regions, as well as the cerebellum (VOIs) were compared. SUV ratio (SUVR) values normalised for the cerebellum were also assessed. Bias, precision and agreement were calculated; statistical significance was evaluated using Wilcoxon matched-pairs signed-rank test. RESULTS Both ZTE- and atlas-AC showed a similar bias of 6-8% in SUV values across the regions. Correlation coefficients with 68Ge-AC were consistently high for ZTE-AC (r 0.99 for all regions), whereas they were lower for atlas-AC, varying from 0.99 in the striatum to 0.88 in the posterior cortical regions. SUVR showed an overall bias of 2.9 and 0.5% for atlas-AC and ZTE-AC, respectively. Correlations with 68Ge-AC were higher for ZTE-AC, varying from 0.99 in the striatum to 0.96 in the limbic regions, compared to atlas-AC (0.99 striatum to 0.77 posterior cortex). CONCLUSIONS Absolute SUV values showed less variability for ZTE-AC than for atlas-AC when compared to 68Ge-AC, but bias was similar for both methods. This bias is largely caused by higher linear attenuation coefficients in atlas- and ZTE-AC image compared to 68Ge-images. For SUVR, bias was lower when using ZTE-AC than for atlas-AC. ZTE-AC shows to be a more robust technique than atlas-AC in terms of both intra- and inter-patient variability.
Collapse
Affiliation(s)
- João M Sousa
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
- PET Centre, Uppsala University Hospital, 75185, Uppsala, Sweden.
| | - Lieuwe Appel
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | | | - Stergios Papadimitriou
- Department of Neurosciences, Uppsala University, Uppsala, Sweden
- Department of Neurology, Uppsala University Hospital, Uppsala, Sweden
| | - Dag Nyholm
- Department of Neurosciences, Uppsala University, Uppsala, Sweden
- Department of Neurology, Uppsala University Hospital, Uppsala, Sweden
| | - Elna-Marie Larsson
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Håkan Ahlström
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Mark Lubberink
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
- Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
6
|
Appel L, Jonasson M, Danfors T, Nyholm D, Askmark H, Lubberink M, Sörensen J. Use of 11C-PE2I PET in differential diagnosis of parkinsonian disorders. J Nucl Med 2015; 56:234-42. [PMID: 25593112 DOI: 10.2967/jnumed.114.148619] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED In idiopathic Parkinson disease and atypical parkinsonian disorders, central dopaminergic and overall brain functional activity are altered to different degrees, causing difficulties in achieving an unambiguous clinical diagnosis. A dual examination using (123)I-FP-CIT ((123)I-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane, or (123)I-ioflupane) SPECT and(18)F-FDG PET provides complementary information on dopamine transporter (DAT) availability and overall brain functional activity, respectively. Parametric images based on a single, dynamic (11)C-PE2I (N-(3-iodoprop-2E-enyl)-2β-carbomethoxy-3β-(4-methyl-phenyl)nortropane) scan potentially supply both DAT availability (nondisplaceable binding potential [BPND]) and relative cerebral blood flow (relative delivery [R1]) at voxel level. This study aimed to evaluate the validity of (11)C-PE2I PET against the dual-modality approach using (123)I-FP-CIT SPECT and (18)F-FDG PET. METHODS Sixteen patients with parkinsonian disorders had a dual examination with (18)F-FDG PET and (123)I-FP-CIT SPECT following clinical routines and additionally an experimental (11)C-PE2I PET scan. Parametric BPND and R1 images were generated using receptor parametric mapping with the cerebellum as a reference. T1-weighted MR imaging was used for automated definition of volumes of interest (VOI). The DAT VOIs included the basal ganglia, whereas the overall brain functional activity was examined using VOIs across the brain. BPND and R1 values were compared with normalized (123)I-FP-CIT and (18)F-FDG uptake values, respectively, using Pearson correlations and regression analyses. In addition, 2 masked interpreters evaluated the images visually, in both the routine and the experimental datasets, for comparison of patient diagnoses. RESULTS Parametric (11)C-PE2I BPND and R1 images showed high consistency with (123)I-FP-CIT SPECT and (18)F-FDG PET images. Correlations between (11)C-PE2I BPND and (123)I-FP-CIT uptake ratios were 0.97 and 0.76 in the putamen and caudate nucleus, respectively. Regional (11)C-PE2I R1 values were moderately to highly correlated with normalized (18)F-FDG values (range, 0.61-0.94). Visual assessment of DAT availability showed a high consistency between (11)C-PE2I BPND and (123)I-FP-CIT images, whereas the consistency was somewhat lower for appraisal of overall brain functional activity using (123)I-FP-CIT and (18)F-FDG images. Substantial differences were found between clinical diagnosis and both neuroimaging diagnoses. CONCLUSION A single, dynamic (11)C-PE2I PET investigation is a powerful alternative to a dual examination with (123)I-FP-CIT SPECT and (18)F-FDG PET for differential diagnosis of parkinsonian disorders. A large-scale patient study is, however, needed to further investigate distinct pathologic patterns in overall brain functional activity for various parkinsonian disorders.
Collapse
Affiliation(s)
- Lieuwe Appel
- PET Centre, Department of Medical Imaging, Uppsala University Hospital, Uppsala, Sweden Section of Nuclear Medicine and PET, Department of Radiology, Oncology, and Radiation Sciences, Uppsala University, Uppsala, Sweden
| | - My Jonasson
- Section of Nuclear Medicine and PET, Department of Radiology, Oncology, and Radiation Sciences, Uppsala University, Uppsala, Sweden Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Torsten Danfors
- PET Centre, Department of Medical Imaging, Uppsala University Hospital, Uppsala, Sweden Section of Nuclear Medicine and PET, Department of Radiology, Oncology, and Radiation Sciences, Uppsala University, Uppsala, Sweden
| | - Dag Nyholm
- Department of Neuroscience, Neurology, Uppsala University, Uppsala, Sweden; and
| | - Håkan Askmark
- Department of Neuroscience, Neurology, Uppsala University, Uppsala, Sweden; and
| | - Mark Lubberink
- Section of Nuclear Medicine and PET, Department of Radiology, Oncology, and Radiation Sciences, Uppsala University, Uppsala, Sweden Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| | - Jens Sörensen
- PET Centre, Department of Medical Imaging, Uppsala University Hospital, Uppsala, Sweden Section of Nuclear Medicine and PET, Department of Radiology, Oncology, and Radiation Sciences, Uppsala University, Uppsala, Sweden
| |
Collapse
|