1
|
Pedersen M, Abbott DF, Jackson GD. Wearable OPM-MEG: A changing landscape for epilepsy. Epilepsia 2022; 63:2745-2753. [PMID: 35841260 PMCID: PMC9805039 DOI: 10.1111/epi.17368] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 07/13/2022] [Accepted: 07/14/2022] [Indexed: 01/09/2023]
Abstract
Magnetoencephalography with optically pumped magnometers (OPM-MEG) is an emerging and novel, cost-effective wearable system that can simultaneously record neuronal activity with high temporal resolution ("when" neuronal activity occurs) and spatial resolution ("where" neuronal activity occurs). This paper will first outline recent methodological advances in OPM-MEG compared to conventional superconducting quantum interference device (SQUID)-MEG before discussing how OPM-MEG can become a valuable and noninvasive clinical support tool in epilepsy surgery evaluation. Although OPM-MEG and SQUID-MEG share similar data features, OPM-MEG is a wearable design that fits children and adults, and it is also robust to head motion within a magnetically shielded room. This means that OPM-MEG can potentially extend the application of MEG into the neurobiology of severe childhood epilepsies with intellectual disabilities (e.g., epileptic encephalopathies) without sedation. It is worth noting that most OPM-MEG sensors are heated, which may become an issue with large OPM sensor arrays (OPM-MEG currently has fewer sensors than SQUID-MEG). Future implementation of triaxial sensors may alleviate the need for large OPM sensor arrays. OPM-MEG designs allowing both awake and sleep recording are essential for potential long-term epilepsy monitoring.
Collapse
Affiliation(s)
- Mangor Pedersen
- Department of Psychology and NeuroscienceAuckland University of TechnologyAucklandNew Zealand
| | - David F. Abbott
- Florey Institute of Neuroscience and Mental HealthMelbourneVictoriaAustralia,Department of Medicine, Austin Health and Florey Department of Neuroscience and Mental HealthUniversity of MelbourneMelbourneVictoriaAustralia
| | - Graeme D. Jackson
- Florey Institute of Neuroscience and Mental HealthMelbourneVictoriaAustralia,Department of Medicine, Austin Health and Florey Department of Neuroscience and Mental HealthUniversity of MelbourneMelbourneVictoriaAustralia
| |
Collapse
|
2
|
Artifact Removal from EEG signals using Regenerative Multi-Dimensional Singular Value Decomposition and Independent Component Analysis. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103452] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
3
|
Baker JM, Bruno JL, Piccirilli A, Gundran A, Harbott LK, Sirkin DM, Marzelli M, Hosseini SMH, Reiss AL. Evaluation of smartphone interactions on drivers' brain function and vehicle control in an immersive simulated environment. Sci Rep 2021; 11:1998. [PMID: 33479322 PMCID: PMC7820246 DOI: 10.1038/s41598-021-81208-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 12/31/2020] [Indexed: 01/29/2023] Open
Abstract
Smartphones and other modern technologies have introduced multiple new forms of distraction that color the modern driving experience. While many smartphone functions aim to improve driving by providing the driver with real-time navigation and traffic updates, others, such as texting, are not compatible with driving and are often the cause of accidents. Because both functions elicit driver attention, an outstanding question is the degree to which drivers' naturalistic interactions with navigation and texting applications differ in regard to brain and behavioral indices of distracted driving. Here, we employed functional near-infrared spectroscopy to examine the cortical activity that occurs under parametrically increasing levels of smartphone distraction during naturalistic driving. Our results highlight a significant increase in bilateral prefrontal and parietal cortical activity that occurs in response to increasingly greater levels of smartphone distraction that, in turn, predicts changes in common indices of vehicle control.
Collapse
Affiliation(s)
- Joseph M Baker
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA.
| | - Jennifer L Bruno
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
| | - Aaron Piccirilli
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
| | - Andrew Gundran
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
| | - Lene K Harbott
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
- Department of Mechanical Engineering, Stanford University, Stanford, CA, 94305, USA
| | - David M Sirkin
- Department of Mechanical Engineering, Stanford University, Stanford, CA, 94305, USA
| | - Matthew Marzelli
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
| | - S M Hadi Hosseini
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
| | - Allan L Reiss
- Division of Brain Sciences, Department of Psychiatry and Behavioral Sciences, Center for Interdisciplinary Brain Sciences Research, School of Medicine, Stanford University, 401 Quarry Rd., Stanford, CA, 94305, USA
- Department of Radiology, Stanford University, Stanford, CA, 94305, USA
| |
Collapse
|
4
|
Kubicek J, Fiedorova K, Vilimek D, Cerny M, Penhaker M, Janura M, Rosicky J. Recent Trends, Construction and Applications of Smart Textiles and Clothing for Monitoring of Health Activity: A Comprehensive Multidisciplinary Review. IEEE Rev Biomed Eng 2020; 15:36-60. [PMID: 33301410 DOI: 10.1109/rbme.2020.3043623] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In the area of biomedical signal monitoring, wearable electronics represents a dynamically growing field with a significant impact on the market of commercial products of biomedical signal monitoring and acquisition, as well as consumer electronic for vital functions monitoring. Since the electrodes are perceived as one of the most important part of the biomedical signal monitoring, they have been one of the most frequent subjects in the research community. Electronic textile (e-textile), also called smart textile represents a modern trend in the wearable electronics, integrating of functional materials with common clothing with the goal to realize the devices, which include sensors, antennas, energy harvesters and advanced textiles for self-cooling and heating. The area of textile electrodes and e-textile is perceived as a multidisciplinary field, integrating material engineering, chemistry, and biomedical engineering. In this review, we provide a comprehensive view on this area. This multidisciplinary review integrates the e-textile characteristics, materials and manufacturing of the textile electrodes, noise influence on the e-textiles performance, and mainly applications of the textile electrodes for biomedical signal monitoring and acquisition, including pressure sensors, electrocardiography, electromyography, electroencephalography and electrooculography monitoring.
Collapse
|
5
|
Schrödinger filtering: a precise EEG despiking technique for EEG-fMRI gradient artifact. Neuroimage 2020; 226:117525. [PMID: 33246129 DOI: 10.1016/j.neuroimage.2020.117525] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 09/22/2020] [Accepted: 10/27/2020] [Indexed: 11/20/2022] Open
Abstract
In EEG data acquired in the presence of fMRI, gradient-related spike artifacts contaminate the signal following the common preprocessing step of average artifact subtraction. Spike artifacts compromise EEG data quality since they overlap with the EEG signal in frequency, thereby confounding frequency-based inferences on activity. As well, spike artifacts can inflate or deflate correlations among time series, thereby confounding inferences on functional connectivity. We present Schrödinger filtering, which uses the Schrödinger equation to decompose the spike-containing input. The basis functions of the decomposition are localized and pulse-shaped, and selectively capture the various input peaks, with the spike components clustered at the beginning of the spectrum. Schrödinger filtering automatically subtracts the spike components from the data. On real and simulated data, we show that Schrödinger filtering (1) simultaneously accomplishes high spike removal and high signal preservation without affecting evoked activity, and (2) reduces spurious pairwise correlations in spontaneous activity. In these regards, Schrödinger filtering was significantly better than three other despiking techniques: median filtering, amplitude thresholding, and wavelet denoising. These results encourage the use of Schrödinger filtering in future EEG-fMRI pipelines, as well as in other spike-related applications (e.g., fMRI motion artifact removal or action potential extraction).
Collapse
|
6
|
Zhang S, Hennig J, LeVan P. Direct modelling of gradient artifacts for EEG-fMRI denoising and motion tracking. J Neural Eng 2019; 16:056010. [PMID: 31216524 DOI: 10.1088/1741-2552/ab2b21] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Simultaneous electroencephalography and functional magnetic resonance imaging recording (EEG-fMRI) has been widely used in neuroscientific and clinical research. The artifacts in the recorded EEG resulting from rapidly switching magnetic field gradients are usually corrected by average-artifact subtraction (AAS) due to their repetitive nature. But the performance of AAS is often disrupted by altered artifact waveforms across epochs, notably due to head motion. APPROACH Here, a method is proposed to make use of the known MR sequence gradient waveforms for a direct modelling of gradient artifacts. After accounting for filtering effects on the gradient artifacts, a continuous modulation of the gradient waveforms superimposed on the EEG signal is obtained. MAIN RESULTS Although a moving AAS template can adjust to slow drifts in gradient artifact variation, it fails to adapt to abrupt motion, resulting in residual noise. We demonstrate how this modelling approach can reduce motion-affected gradient artifacts without distorting the underlying neuronal signals. Moreover, the method provides useful head motion information highly correlated with motion tracked by an optical camera. SIGNIFICANCE Our work provides a novel way to improve gradient artifact removal in EEG-fMRI, and shows a potential to detect head motion without requiring additional hardware.
Collapse
Affiliation(s)
- Shuoyue Zhang
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | | |
Collapse
|
7
|
Neuner I, Rajkumar R, Brambilla CR, Ramkiran S, Ruch A, Orth L, Farrher E, Mauler J, Wyss C, Kops ER, Scheins J, Tellmann L, Lang M, Ermert J, Dammers J, Neumaier B, Lerche C, Heekeren K, Kawohl W, Langen KJ, Herzog H, Shah NJ. Simultaneous PET-MR-EEG: Technology, Challenges and Application in Clinical Neuroscience. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019. [DOI: 10.1109/trpms.2018.2886525] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
8
|
Daniel AJ, Smith JA, Spencer GS, Jorge J, Bowtell R, Mullinger KJ. Exploring the relative efficacy of motion artefact correction techniques for EEG data acquired during simultaneous fMRI. Hum Brain Mapp 2018; 40:578-596. [PMID: 30339731 PMCID: PMC6492138 DOI: 10.1002/hbm.24396] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 08/30/2018] [Accepted: 08/31/2018] [Indexed: 11/25/2022] Open
Abstract
Simultaneous EEG‐fMRI allows multiparametric characterisation of brain function, in principle enabling a more complete understanding of brain responses; unfortunately the hostile MRI environment severely reduces EEG data quality. Simply eliminating data segments containing gross motion artefacts [MAs] (generated by movement of the EEG system and head in the MRI scanner's static magnetic field) was previously believed sufficient. However recently the importance of removal of all MAs has been highlighted and new methods developed. A systematic comparison of the ability to remove MAs and retain underlying neuronal activity using different methods of MA detection and post‐processing algorithms is needed to guide the neuroscience community. Using a head phantom, we recorded MAs while simultaneously monitoring the motion using three different approaches: Reference Layer Artefact Subtraction (RLAS), Moiré Phase Tracker (MPT) markers and Wire Loop Motion Sensors (WLMS). These EEG recordings were combined with EEG responses to simple visual tasks acquired on a subject outside the MRI environment. MAs were then corrected using the motion information collected with each of the methods combined with different analysis pipelines. All tested methods retained the neuronal signal. However, often the MA was not removed sufficiently to allow accurate detection of the underlying neuronal signal. We show that the MA is best corrected using the RLAS combined with post‐processing using a multichannel, recursive least squares (M‐RLS) algorithm. This method needs to be developed further to enable practical utility; thus, WLMS combined with M‐RLS currently provides the best compromise between EEG data quality and practicalities of motion detection.
Collapse
Affiliation(s)
- Alexander J Daniel
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - James A Smith
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - Glyn S Spencer
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom.,Department of Physics, Loughborough University, Leicestershire, United Kingdom
| | - João Jorge
- Laboratory for Functional and Metabolic Imaging, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom
| | - Karen J Mullinger
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom.,Birmingham University Imaging Centre, School of Psychology, University of Birmingham, Birmingham, United Kingdom
| |
Collapse
|