1
|
Ariwanto B, Ain K, Rulaningtyas R, Ukhrowiyah N, Aisya R, Basori AH, Mansur ABF. Multifrequency electrical impedance tomography (Mf-EIT) for the detection of breast cancer phantom anomalies. MethodsX 2025; 14:103087. [PMID: 39758433 PMCID: PMC11699602 DOI: 10.1016/j.mex.2024.103087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Accepted: 12/05/2024] [Indexed: 01/07/2025] Open
Abstract
Breast cancer is the most commonly diagnosed neoplasm and one of the most widespread cancers among women. The research advanced the Mf-EIT hardware through analogue discovery, component assessment, hardware integration, software creation, and data reconstruction utilizing Gauss-Newton and GREIT approaches. The breast cancer phantom consisted of a gelatin and sodium chloride solution. The position and number of anomalies in the reconstructed image correspond with the phantom. Anomalies in the reconstructed image are illustrated in red, indicating that they exhibit higher conductivity than their environment. The smallest percentage difference in conductivity between the reconstructed image of the cancer abnormality and the phantom is 0.18 %, recorded at a current of 0.35 mA and a frequency of 150 kHz. The smallest percentage difference in size between cancer abnormalities 1 and 2 in the reconstructed image and the phantom is 0.14 %, observed at a current of 0.22 mA and a frequency of 80 kHz. In brief,•This study proposes an innovative Electrical Impedance Tomography (EIT)•The designed and built the Mf-EIT hardware based on data reconstruction using Gauss-Newton and GREIT•The Electrical Impedance Tomography designed to detect the anomalies in the reconstructed image of Breast Cancer.
Collapse
Affiliation(s)
- Bayu Ariwanto
- Magister of Biomedical Engineering, Faculty of Science and Technology, Airlangga University, Surabaya 60115, Indonesia
| | - Khusnul Ain
- Magister of Biomedical Engineering, Faculty of Science and Technology, Airlangga University, Surabaya 60115, Indonesia
| | - Riries Rulaningtyas
- Magister of Biomedical Engineering, Faculty of Science and Technology, Airlangga University, Surabaya 60115, Indonesia
| | - Nuril Ukhrowiyah
- Magister of Biomedical Engineering, Faculty of Science and Technology, Airlangga University, Surabaya 60115, Indonesia
| | - Rohadatul Aisya
- Magister of Biomedical Engineering, Faculty of Science and Technology, Airlangga University, Surabaya 60115, Indonesia
| | - Ahmad Hoirul Basori
- Faculty of Computing and Information Technology in Rabigh, King Abdulaziz University, Rabigh 21911, Saudi Arabia
| | - Andi Besse Fidausiah Mansur
- Faculty of Computing and Information Technology in Rabigh, King Abdulaziz University, Rabigh 21911, Saudi Arabia
| |
Collapse
|
2
|
Fourie F, Thiselton J, Hanekom T. Can a Cochlear Implant Be Used as an Electrical Impedance Tomography Device? INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2025; 41:e3907. [PMID: 39835713 PMCID: PMC11748830 DOI: 10.1002/cnm.3907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 11/18/2024] [Accepted: 12/29/2024] [Indexed: 01/22/2025]
Abstract
The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios. In this article, EIT is investigated as an alternative method to image and extract the centre of gravity of the modiolus in vivo. This information can be used to augment present postoperative medical imaging techniques to investigate the cochlea. The cochlear implant EIT system was simulated by modelling user-specific electrode array trajectories within a simple conductive medium containing an inhomogeneity representing the modiolus. The method included an adapted adjacent stimulation protocol for data collection. For the image reconstruction, NOSER and Tikhonov priors were considered. A parameter analysis was conducted to find the most robust combination of image priors and hyperparameters for this application. The cochlear implant EIT methodology was validated at different noise levels for four electrode array trajectories. Comparing the NOSER and Tikhonov priors, it was observed that the NOSER prior exhibits superior centre of gravity localisation performance in cochlear implant EIT image reconstruction for different noise levels and user-dependent variability in electrode array trajectories. Image reconstruction, using a NOSER prior at a hyperparameter value of approximately 0.001, resulted in an average centre of gravity localisation error of less than 4% for all electrode array trajectories using difference imaging and less than 5.5% using absolute imaging.
Collapse
Affiliation(s)
- Friedemarie Fourie
- Bioengineering, Department of Electrical, Electronic and Computer EngineeringUniversity of PretoriaGautengSouth Africa
| | - Joshua Thiselton
- Bioengineering, Department of Electrical, Electronic and Computer EngineeringUniversity of PretoriaGautengSouth Africa
| | - Tania Hanekom
- Bioengineering, Department of Electrical, Electronic and Computer EngineeringUniversity of PretoriaGautengSouth Africa
| |
Collapse
|
3
|
Wang W, Zhu M, Liu B, Li W, Wang Y, Li J, Guo Q, Du F, Xu C, Shi X. Temperature and Frequency Dependence of Human Cerebrospinal Fluid Dielectric Parameters. SENSORS (BASEL, SWITZERLAND) 2024; 24:7394. [PMID: 39599169 PMCID: PMC11598596 DOI: 10.3390/s24227394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2024] [Revised: 11/06/2024] [Accepted: 11/11/2024] [Indexed: 11/29/2024]
Abstract
Accurate human cerebrospinal fluid (CSF) dielectric parameters are critical for biological electromagnetic applications such as the electromagnetic field modelling of the human brain, the localization and intensity assessment of electrical generators in the brain, and electromagnetic protection. To detect brain damage signals during temperature changes by electrical impedance tomography (EIT), the change in CSF dielectric parameters with frequency (10 Hz-100 MHz) and temperature (17-39 °C) was investigated. A Debye model was first established to capture the complex impedance frequency and temperature characteristics. Furthermore, the receiver operating characteristic (ROC) analysis based on the dielectric parameters of normal and diseased CSF was carried out to identify lesions. The Debye model's characteristic fc parameters linearly increased with increasing temperature (R2 = 0.989), and R0 and R1 linearly decreased (R2 = 0.990). The final established formula can calculate the complex impedivity of CSF with a maximum fitting error of 3.79%. Furthermore, the ROC based on the real part of impedivity at 10 Hz and 17 °C yielded an area under the curve (AUC) of 0.898 with a specificity of 0.889 and a sensitivity of 0.944. These findings are expected to facilitate the application of electromagnetic technology, such as disease diagnosis, specific absorption rate calculation, and biosensor design.
Collapse
Affiliation(s)
- Weice Wang
- Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Air Force Medical University, Xi’an 710032, China; (W.W.); (M.Z.); (J.L.)
| | - Mingxu Zhu
- Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Air Force Medical University, Xi’an 710032, China; (W.W.); (M.Z.); (J.L.)
| | - Benyuan Liu
- Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Air Force Medical University, Xi’an 710032, China; (W.W.); (M.Z.); (J.L.)
| | - Weichen Li
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University, Xi’an 710000, China;
| | - Yu Wang
- Institute of Medical Research, Northwestern Polytechnical University, Xi’an 710072, China;
| | - Junyao Li
- Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Air Force Medical University, Xi’an 710032, China; (W.W.); (M.Z.); (J.L.)
| | - Qingdong Guo
- Department of Neurosurgery, Xijing Hospital, Air Force Medical University, Xi’an 710032, China
| | - Fang Du
- Department of Neurology, Xijing Hospital, Air Force Medical University, Xi’an 710032, China
| | - Canhua Xu
- Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Air Force Medical University, Xi’an 710032, China; (W.W.); (M.Z.); (J.L.)
| | - Xuetao Shi
- Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Air Force Medical University, Xi’an 710032, China; (W.W.); (M.Z.); (J.L.)
| |
Collapse
|
4
|
Mason K, Maurino-Alperovich F, Holder D, Aristovich K. Noise-based correction for electrical impedance tomography. Physiol Meas 2024; 45:065002. [PMID: 38772395 DOI: 10.1088/1361-6579/ad4e93] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 05/21/2024] [Indexed: 05/23/2024]
Abstract
Objective.Noisy measurements frequently cause noisy and inaccurate images in impedance imaging. No post-processing technique exists to calculate the propagation of measurement noise and use this to suppress noise in the image. The objectives of this work were (1) to develop a post-processing method for noise-based correction (NBC) in impedance tomography, (2) to test whether NBC improves image quality in electrical impedance tomography (EIT), (3) to determine whether it is preferable to use correlated or uncorrelated noise for NBC, (4) to test whether NBC works within vivodata and (5) to test whether NBC is stable across model and perturbation geometries.Approach.EIT was performedin silicoin a 2D homogeneous circular domain and an anatomically realistic, heterogeneous 3D human head domain for four perturbations and 25 noise levels in each case. This was validated by performing EIT for four perturbations in a circular, saline tank in 2D as well as a human head-shaped saline tank with a realistic skull-like layer in 3D. Images were assessed on the error in the weighted spatial variance (WSV) with respect to the true, target image. The effect of NBC was also tested forin vivoEIT data of lung ventilation in a human thorax and cortical activity in a rat brain.Main results.On visual inspection, NBC maintained or increased image quality for all perturbations and noise levels in 2D and 3D, both experimentally andin silico. Analysis of the WSV showed that NBC significantly improved the WSV in nearly all cases. When the WSV was inferior with NBC, this was either visually imperceptible or a transformation between noisy reconstructions. Forin vivodata, NBC improved image quality in all cases and preserved the expected shape of the reconstructed perturbation.Significance.In practice, uncorrelated NBC performed better than correlated NBC and is recommended as a general-use post-processing technique in EIT.
Collapse
Affiliation(s)
- Kai Mason
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | | | - David Holder
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Kirill Aristovich
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| |
Collapse
|
5
|
Hashemi A, Cai C, Gao Y, Ghosh S, Muller KR, Nagarajan SS, Haufe S. Joint Learning of Full-Structure Noise in Hierarchical Bayesian Regression Models. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:610-624. [PMID: 36423312 DOI: 10.1109/tmi.2022.3224085] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
We consider the reconstruction of brain activity from electroencephalography (EEG). This inverse problem can be formulated as a linear regression with independent Gaussian scale mixture priors for both the source and noise components. Crucial factors influencing the accuracy of the source estimation are not only the noise level but also its correlation structure, but existing approaches have not addressed the estimation of noise covariance matrices with full structure. To address this shortcoming, we develop hierarchical Bayesian (type-II maximum likelihood) models for observations with latent variables for source and noise, which are estimated jointly from data. As an extension to classical sparse Bayesian learning (SBL), where across-sensor observations are assumed to be independent and identically distributed, we consider Gaussian noise with full covariance structure. Using the majorization-maximization framework and Riemannian geometry, we derive an efficient algorithm for updating the noise covariance along the manifold of positive definite matrices. We demonstrate that our algorithm has guaranteed and fast convergence and validate it in simulations and with real MEG data. Our results demonstrate that the novel framework significantly improves upon state-of-the-art techniques in the real-world scenario where the noise is indeed non-diagonal and full-structured. Our method has applications in many domains beyond biomagnetic inverse problems.
Collapse
|
6
|
Zhang W, Jiao Y, Zhang T, Liu X, Ye J, Zhang Y, Yang B, Dai M, Shi X, Fu F, Wang L, Xu C. Early detection of acute ischemic stroke using Contrast-enhanced electrical impedance tomography perfusion. Neuroimage Clin 2023; 39:103456. [PMID: 37379734 PMCID: PMC10318520 DOI: 10.1016/j.nicl.2023.103456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 06/08/2023] [Accepted: 06/19/2023] [Indexed: 06/30/2023]
Abstract
A cerebral contrast-enhanced electrical impedance tomography perfusion method is developed for acute ischemic stroke during intravenous thrombolytic therapy. Several clinical contrast agents with stable impedance characteristics and high-conductivity contrast were screened experimentally as electrical impedance contrast agent candidates. The electrical impedance tomography perfusion method was tested on rabbits with focal cerebral infarction, and its capability for early detection was verified based on perfusion images. The experimental results showed that ioversol 350 performed significantly better as an electrical impedance contrast agent than other contrast agents (p < 0.01). Additionally, perfusion images of focal cerebral infarction in rabbits confirmed that the electrical impedance tomography perfusion method could accurately detect the location and area of different cerebral infarction lesions (p < 0.001). Therefore, the cerebral contrast-enhanced electrical impedance tomography perfusion method proposed herein combines traditional, dynamic continuous imaging with rapid detection and could be applied as an early, rapid-detection, auxiliary, bedside imaging method for patients after a suspected ischemic stroke in both prehospital and in-hospital settings.
Collapse
Affiliation(s)
- Weirui Zhang
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China; Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Yang Jiao
- Department of Neurosurgery, Tangdu Hospital of Fourth Military Medical University, Xi'an 710032, People's Republic of China
| | - Tao Zhang
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China; Drug and Instrument Supervision and Inspection Station, Xining Joint Logistics Support Center, Lanzhou 730050, People's Republic of China
| | - Xuechao Liu
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Jianan Ye
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Yuyan Zhang
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Bin Yang
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Meng Dai
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Xuetao Shi
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Feng Fu
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China
| | - Liang Wang
- Department of Neurosurgery, Tangdu Hospital of Fourth Military Medical University, Xi'an 710032, People's Republic of China
| | - Canhua Xu
- Department of Biomedical Engineering, the Fourth Military Medical University, Xi'an 710032, People's Republic of China; Shaanxi Key Laboratory for Bioelectromagnetic Detection and Intelligent Perception, Xi'an 710032, People's Republic of China.
| |
Collapse
|
7
|
Pennati F, Angelucci A, Morelli L, Bardini S, Barzanti E, Cavallini F, Conelli A, Di Federico G, Paganelli C, Aliverti A. Electrical Impedance Tomography: From the Traditional Design to the Novel Frontier of Wearables. SENSORS (BASEL, SWITZERLAND) 2023; 23:1182. [PMID: 36772222 PMCID: PMC9921522 DOI: 10.3390/s23031182] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/16/2023] [Accepted: 01/17/2023] [Indexed: 06/18/2023]
Abstract
Electrical impedance tomography (EIT) is a medical imaging technique based on the injection of a current or voltage pattern through electrodes on the skin of the patient, and on the reconstruction of the internal conductivity distribution from the voltages collected by the electrodes. Compared to other imaging techniques, EIT shows significant advantages: it does not use ionizing radiation, is non-invasive and is characterized by high temporal resolution. Moreover, its low cost and high portability make it suitable for real-time, bedside monitoring. However, EIT is also characterized by some technical limitations that cause poor spatial resolution. The possibility to design wearable devices based on EIT has recently given a boost to this technology. In this paper we reviewed EIT physical principles, hardware design and major clinical applications, from the classical to a wearable setup. A wireless and wearable EIT system seems a promising frontier of this technology, as it can both facilitate making clinical measurements and open novel scenarios to EIT systems, such as home monitoring.
Collapse
Affiliation(s)
| | - Alessandra Angelucci
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milan, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Emerging trends and hot spots on electrical impedance tomography extrapulmonary applications. Heliyon 2022; 8:e12458. [PMID: 36619470 PMCID: PMC9812712 DOI: 10.1016/j.heliyon.2022.e12458] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 10/17/2022] [Accepted: 12/13/2022] [Indexed: 01/04/2023] Open
Abstract
Objective Electrical impedance tomography (EIT) develops rapidly in technology and applications. Nowadays EIT is used in multiple clinical and experimental scenarios including pulmonary, brain, and tissue monitoring, etc. The present study explores the research trends and hotspots on EIT extrapulmonary application research by bibliometrics analysis. Approach Publications on EIT extrapulmonary applications between 1987 and 2021 were retrieved from the Web of Science Core Collection database. For precise screening, search strategy "electrical impedance tomography" plus "hemodynamic" or "brain" or "nerve" or "cancer" or "venous" or "vessel" or "tumor" or "veterinary" or "tissue" or "cell" or "wearable" or "application" and excluding "lung", "ventilation" "respiratory", "pulmonary", "algorithm", "current", "voltage" or "electrode" were used. CiteSpace and VOSviewer were used to analyze the publication features, collaboration, keywords co-occurrence, and co-cited reference. Main results A total of 506 articles were finally identified. The global publication numbers on extrapulmonary applications gradually increased yearly in the past 30 years. The US, UK, and China contributed most three publications concerning EIT extrapulmonary applications. "tissues", "conductivity", "model" were research hotspots, and "cutaneous melanoma", "microstructure", "diagnosis" were recent topics (Portions of this research have previously been presented in poster form). Significance Overall, EIT extrapulmonary applications bibliometrics analysis provides a unique insight into research focus, current trends, and future directions.
Collapse
|
9
|
Wang L, Zhu W, Wang R, Li W, Liang G, Ji Z, Dong X, Shi X. Suppressing interferences of EIT on synchronous recording EEG based on comb filter for seizure detection. Front Neurol 2022; 13:1070124. [DOI: 10.3389/fneur.2022.1070124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 11/18/2022] [Indexed: 12/03/2022] Open
Abstract
Background and objectiveThe purpose of this study was to eliminate the interferences of electrical impedance tomography (EIT) on synchronous recording electroencephalography (EEG) for seizure detection.MethodsThe simulated EIT signal generated by COMSOL Multiphysics was superimposed on the clinical EEG signal obtained from the CHB-MIT Scalp EEG Database, and then the spectrum features of superimposed mixed signals were analyzed. According to the spectrum analysis, in addition to high-frequency interference at 51.2 kHz related to the drive current, there was also low-frequency interference caused by switching of electrode pairs, which were used to inject drive current. A low pass filter and a comb filter were used to suppress the high-frequency interference and low-frequency interference, respectively. Simulation results suggested the low-pass filter and comb filter working together effectively filtered out the interference of EIT on EEG in the process of synchronous monitoring.ResultsAs a result, the normal EEG and epileptic EEG could be recognized effectively. Pearson correlation analysis further confirmed the interference of EIT on EEG was effectively suppressed.ConclusionsThis study provides a simple and effective interference suppression method for the synchronous monitoring of EIT and EEG, which could be served as a reference for the synchronous monitoring of EEG and other medical electromagnetic devices.
Collapse
|
10
|
Wang R, Zhu W, Liang G, Xu J, Guo J, Wang L. Animal models for epileptic foci localization, seizure detection, and prediction by electrical impedance tomography. WILEY INTERDISCIPLINARY REVIEWS. COGNITIVE SCIENCE 2022; 13:e1619. [PMID: 36093634 DOI: 10.1002/wcs.1619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 07/08/2022] [Accepted: 07/14/2022] [Indexed: 06/15/2023]
Abstract
Surgical resection of lesions and closed-loop suppression are the two main treatment options for patients with refractory epilepsy whose symptoms cannot be managed with medicines. Unfortunately, failures in foci localization and seizure prediction are constraining these treatments. Electrical impedance tomography (EIT), sensitive to impedance changes caused by blood flow or cell swelling, is a potential new way to locate epileptic foci and predict seizures. Animal validation is a necessary research process before EIT can be used in clinical practice, but it is unclear which among the many animal epilepsy models is most suited to this task. The selection of an animal model of epilepsy that is similar to human seizures and can be adapted to EIT is important for the accuracy and reliability of EIT research results. This study provides an overview of the animal models of epilepsy that have been used in research on the use of EIT to locate the foci or predict seizures; discusses the advantages and disadvantages of these models regarding inducement by chemical convulsant and electrical stimulation; and finally proposes optimal animal models of epilepsy to obtain more convincing research results for foci localization and seizure prediction by EIT. The ultimate goal of this study is to facilitate the development of new treatments for patients with refractory epilepsy. This article is categorized under: Neuroscience > Clinical Neuroscience Psychology > Brain Function and Dysfunction.
Collapse
Affiliation(s)
- Rong Wang
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Wenjing Zhu
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Guohua Liang
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Jiaming Xu
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Jie Guo
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Lei Wang
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| |
Collapse
|
11
|
Tarotin I, Mastitskaya S, Ravagli E, Perkins JD, Holder D, Aristovich K. Overcoming temporal dispersion for measurement of activity-related impedance changes in unmyelinated nerves. J Neural Eng 2022; 19. [PMID: 35413701 DOI: 10.1088/1741-2552/ac669a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2022] [Accepted: 04/11/2022] [Indexed: 11/11/2022]
Abstract
Objective.Fast neural electrical impedance tomography is an imaging technique that has been successful in visualising electrically evoked activity of myelinated fibres in peripheral nerves by measurement of the impedance changes (dZ) accompanying excitation. However, imaging of unmyelinated fibres is challenging due to temporal dispersion (TP) which occurs due to variability in conduction velocities of the fibres and leads to a decrease of the signal below the noise with distance from the stimulus. To overcome TP and allow electrical impedance tomography imaging in unmyelinated nerves, a new experimental and signal processing paradigm is required allowing dZ measurement further from the site of stimulation than compound neural activity is visible. The development of such a paradigm was the main objective of this study.Approach.A finite element-based statistical model of TP in porcine subdiaphragmatic nerve was developed and experimentally validatedex-vivo. Two paradigms for nerve stimulation and processing of the resulting data-continuous stimulation and trains of stimuli, were implemented; the optimal paradigm for recording dispersed dZ in unmyelinated nerves was determined.Main results.While continuous stimulation and coherent spikes averaging led to higher signal-to-noise ratios (SNRs) at close distances from the stimulus, stimulation by trains was more consistent across distances and allowed dZ measurement at up to 15 cm from the stimulus (SNR = 1.8 ± 0.8) if averaged for 30 min.Significance.The study develops a method that for the first time allows measurement of dZ in unmyelinated nerves in simulation and experiment, at the distances where compound action potentials are fully dispersed.
Collapse
Affiliation(s)
- Ilya Tarotin
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Svetlana Mastitskaya
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Enrico Ravagli
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Justin D Perkins
- Clinical Science and Services, Royal Veterinary College, Hawkshead Lane, Hatfield, United Kingdom
| | - David Holder
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Kirill Aristovich
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| |
Collapse
|
12
|
Ke XY, Hou W, Huang Q, Hou X, Bao XY, Kong WX, Li CX, Qiu YQ, Hu SY, Dong LH. Advances in electrical impedance tomography-based brain imaging. Mil Med Res 2022; 9:10. [PMID: 35227324 PMCID: PMC8883715 DOI: 10.1186/s40779-022-00370-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 02/08/2022] [Indexed: 11/10/2022] Open
Abstract
Novel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. Electrical impedance tomography (EIT) is a functional imaging technique that measures the transfer impedances between electrodes on the body surface to estimate the spatial distribution of electrical properties of tissues. EIT offers many advantages over other neuroimaging technologies, which has led to its potential clinical use. This qualitative review provides an overview of the basic principles, algorithms, and system composition of EIT. Recent advances in the field of EIT are discussed in the context of epilepsy, stroke, brain injuries and edema, and other brain diseases. Further, we summarize factors limiting the development of brain EIT and highlight prospects for the field. In epilepsy imaging, there have been advances in EIT imaging depth, from cortical to subcortical regions. In stroke research, a bedside EIT stroke monitoring system has been developed for clinical practice, and data support the role of EIT in multi-modal imaging for diagnosing stroke. Additionally, EIT has been applied to monitor the changes in brain water content associated with cerebral edema, enabling the early identification of brain edema and the evaluation of mannitol dehydration. However, anatomically realistic geometry, inhomogeneity, cranium completeness, anisotropy and skull type, etc., must be considered to improve the accuracy of EIT modeling. Thus, the further establishment of EIT as a mature and routine diagnostic technique will necessitate the accumulation of more supporting evidence.
Collapse
Affiliation(s)
- Xi-Yang Ke
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Qi Huang
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China
| | - Xue Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Xue-Ying Bao
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei-Xuan Kong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China
| | - Cheng-Xiang Li
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Yu-Qi Qiu
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Si-Yi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China.
| | - Li-Hua Dong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China. .,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China. .,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| |
Collapse
|
13
|
Hannan S, Aristovich K, Faulkner M, Avery J, Walker MC, Holder DS. Imaging slow brain activity during neocortical and hippocampal epileptiform events with electrical impedance tomography. Physiol Meas 2021; 42:014001. [PMID: 33361567 DOI: 10.1088/1361-6579/abd67a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE Electrical impedance tomography (EIT) is an imaging technique that produces tomographic images of internal impedance changes within an object using surface electrodes. It can be used to image the slow increase in cerebral tissue impedance that occurs over seconds during epileptic seizures, which is attributed to cell swelling due to disturbances in ion homeostasis following hypersynchronous neuronal firing and its associated metabolic demands. In this study, we characterised and imaged this slow impedance response during neocortical and hippocampal epileptiform events in the rat brain and evaluated its relationship to the underlying neural activity. APPROACH Neocortical or hippocampal seizures, comprising repeatable series of high-amplitude ictal spikes, were induced by electrically stimulating the sensorimotor cortex or perforant path of rats anaesthetised with fentanyl-isoflurane. Transfer impedances were measured during ≥30 consecutive seizures, by applying a sinusoidal current through independent electrode pairs on an epicortical array, and combined to generate an EIT image of slow activity. MAIN RESULTS The slow impedance responses were consistently time-matched to the end of seizures and EIT images of this activity were reconstructed reproducibly in all animals (p < 0.03125, N = 5). These displayed foci of activity that were spatially confined to the facial somatosensory cortex and dentate gyrus for neocortical and hippocampal seizures, respectively, and encompassed a larger volume as the seizure progressed. Centre-of-mass analysis of reconstructions revealed that this activity corresponded to the true location of the epileptogenic zone, as determined by EEG recordings and fast neural EIT measurements which were obtained simultaneously. SIGNIFICANCE These findings suggest that the slow impedance response presents a reliable marker of hypersynchronous neuronal activity during epileptic seizures and can thus be utilised for investigating the mechanisms of epileptogenesis in vivo and for aiding localisation of the epileptogenic zone during presurgical evaluation of patients with refractory epilepsies.
Collapse
Affiliation(s)
- Sana Hannan
- Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| | - Kirill Aristovich
- Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| | - Mayo Faulkner
- Wolfson Institute for Biomedical Research, University College London, United Kingdom
| | - James Avery
- Department of Surgery and Cancer, Imperial College London, United Kingdom
| | - Matthew C Walker
- UCL Queen Square Institute of Neurology, University College London, United Kingdom
| | - David S Holder
- Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| |
Collapse
|
14
|
Mansouri S, Alharbi Y, Haddad F, Chabcoub S, Alshrouf A, Abd-Elghany AA. Electrical Impedance Tomography - Recent Applications and Developments. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2021; 12:50-62. [PMID: 35069942 PMCID: PMC8667811 DOI: 10.2478/joeb-2021-0007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Indexed: 06/12/2023]
Abstract
Electrical impedance tomography (EIT) is a low-cost noninvasive imaging method. The main purpose of this paper is to highlight the main aspects of the EIT method and to review the recent advances and developments. The advances in instrumentation and in the different image reconstruction methods and systems are demonstrated in this review. The main applications of the EIT are presented and a special attention made to the papers published during the last years (from 2015 until 2020). The advantages and limitations of EIT are also presented. In conclusion, EIT is a promising imaging approach with a strong potential that has a large margin of progression before reaching the maturity phase.
Collapse
Affiliation(s)
- Sofiene Mansouri
- Department of Biomedical Technology, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia
- Laboratory of Biophysics and Medical Technologies, Higher Institute of Medical Technologies of Tunis, University of Tunis El Manar, TunisTunisia
| | - Yousef Alharbi
- Department of Biomedical Technology, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia
| | - Fatma Haddad
- Laboratory of Biophysics and Medical Technologies, Higher Institute of Medical Technologies of Tunis, University of Tunis El Manar, TunisTunisia
| | - Souhir Chabcoub
- Laboratory of Biophysics and Medical Technologies, Higher Institute of Medical Technologies of Tunis, University of Tunis El Manar, TunisTunisia
| | - Anwar Alshrouf
- Department of Biomedical Technology, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia
| | - Amr A. Abd-Elghany
- Department of Biomedical Technology, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Al-Kharj, Saudi Arabia
- Biophysics Department, Faculty of Science, Cairo University, CairoEgypt
| |
Collapse
|
15
|
Development of a Portable, Reliable and Low-Cost Electrical Impedance Tomography System Using an Embedded System. ELECTRONICS 2020. [DOI: 10.3390/electronics10010015] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Electrical impedance tomography (EIT) is a useful procedure with applications in industry and medicine, particularly in the lungs and brain area. In this paper, the development of a portable, reliable and low-cost EIT system for image reconstruction by using an embedded system (ES) is introduced herein. The novelty of this article is the hardware development of a complete low-cost EIT system, as well as three simple and efficient algorithms that can be implemented on ES. The proposed EIT system applies the adjacent voltage method, starting with an impedance acquisition stage that sends data to a Raspberry Pi 4 (RPi4) as ES. To perform the image reconstruction, a user interface was developed by using GNU Octave for RPi4 and the EIDORS library. A statistical analysis is performed to determine the best average value from the samples measured by using an analog-to-digital converter (ADC) with a capacity of 30 kSPS and 24-bit resolution. The tests for the proposed EIT system were performed using materials such as metal, glass and an orange to simulate its application in food industry. Experimental results show that the statistical median is more accurate with respect to the real voltage measurement; however, it represents a higher computational cost. Therefore, the mean is calculated and improved by discarding data values in a transitory state, achieving better accuracy than the median to determine the real voltage value, enhancing the quality of the reconstructed images. A performance comparison between a personal computer (PC) and RPi4 is presented. The proposed EIT system offers an excellent cost-benefit ratio with respect to a traditional PC, taking into account precision, accuracy, energy consumption, price, light weight, size, portability and reliability. The proposed EIT system has potential application in mechanical ventilation, food industry and structural health monitoring.
Collapse
|
16
|
Hannan S, Faulkner M, Aristovich K, Avery J, Walker MC, Holder DS. Optimised induction of on-demand focal hippocampal and neocortical seizures by electrical stimulation. J Neurosci Methods 2020; 346:108911. [DOI: 10.1016/j.jneumeth.2020.108911] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 08/10/2020] [Accepted: 08/12/2020] [Indexed: 11/25/2022]
|