1
|
Taeby A, Seyyedi SA, Mostafavi M. In vitro accuracy of ultra-low dose cone-beam CT for detection of proximal caries. Dentomaxillofac Radiol 2024; 53:459-467. [PMID: 38976634 DOI: 10.1093/dmfr/twae030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 03/24/2024] [Accepted: 07/02/2024] [Indexed: 07/10/2024] Open
Abstract
OBJECTIVES This study aimed to assess the accuracy of ultra-low dose (ULD) cone-beam CT (CBCT) for detection of proximal caries. METHODS This in vitro study evaluated 104 molar and premolar teeth. The teeth were mounted in dry skulls and underwent CBCT with 4 protocols of high-resolution (HR), normal (NORM), ULD-HR, and ULD-NORM; 78 CBCT images were scored by 3 observers for the presence and penetration depth of caries twice with a 2-week interval using a 5-point Likert scale. The teeth were then sectioned and observed under a stereomicroscope (gold standard). The 4 protocols were compared with each other and with the gold standard. The receiver operating characteristic curve was drawn, and the area under the curve (AUC) was calculated and compared by the Chi-square test (alpha = .05). RESULTS The interobserver agreement ranged from 0.5233 to 0.6034 for ULD-NORM, 0.5380 to 0.6279 for NORM, 0.5856 to 0.6300 for ULD-HR, and 0.6614 to 0.7707 for HR images. The intra-observer agreement ranged from 0.6027 to 0.8812 for ULD-HR, 0.7083 to 0.7556 for HR, 0.6076 to 0.9452 for ULD-NORM, and 0.7012 to 0.9221 for NORM images. Comparison of AUC revealed no significant difference between NORM and ULD-NORM (P > .05), or HR and ULD-HR (P > .05). The highest AUC belonged to HR (0.8529) and the lowest to NORM (0.7774). CONCLUSIONS Considering the significant reduction in radiation dose in ULD CBCT and its acceptable diagnostic accuracy for detection of proximal caries, this protocol may be used for detection of proximal carious lesions and assessment of their depth.
Collapse
Affiliation(s)
- Aria Taeby
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Urmia University of Medical Sciences, Orzhans Alley, Resalat St., Urmia, west Azerbaijan Province, 5714783734, Iran
| | - Seyyed Amir Seyyedi
- Department of Oral and Maxillofacial Medicine, School of Dentistry, Urmia University of Medical Sciences, Orzhans Alley, Resalat St., Urmia, west Azerbaijan Province, 5714783734, Iran
| | - Maryam Mostafavi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Urmia University of Medical Sciences, Orzhans Alley, Resalat St., Urmia, west Azerbaijan Province, 5714783734, Iran
| |
Collapse
|
2
|
Abesi F, Talachi F, Ezoji F. Performance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials. Pol J Radiol 2024; 89:e281-e291. [PMID: 39040560 PMCID: PMC11262014 DOI: 10.5114/pjr/188257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 05/03/2024] [Indexed: 07/24/2024] Open
Abstract
Purpose We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups.
Collapse
Affiliation(s)
- Farida Abesi
- Dental Materials Research Centre, Department of Oral and Maxillofacial Radiology, Dental Faculty, Babol University of Medical Sciences, Babol, Iran
| | | | - Fariba Ezoji
- Dental Materials Research Centre, Health Research Institute, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran
| |
Collapse
|
3
|
Bastos MF, Visconti MA, Pinto RR, Junqueira RB, Verner FS. Assessing the Impact of the Metal Artifact Reduction Tool on Detecting Furcation Lesions in Maxillary Molars with Different Intracanal Posts: An Ex Vivo Cone-beam Computed Tomography Study. J Endod 2024; 50:835-843. [PMID: 38395388 DOI: 10.1016/j.joen.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 02/11/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024]
Abstract
INTRODUCTION Considering the potential image compromise and diagnostic challenges posed by metals, this study aimed to assess the efficacy of the metal artifact reduction (MAR) tool in cone-beam computed tomography examinations for detecting furcation lesions in upper molars treated endodontically and restored with different intracanal posts. METHODS This ex vivo study used 45 endodontically treated maxillary first molars, categorized into the following3 groups (n = 15): control (without intracanal post), metal post, and fiberglass post. Simulations were conducted in the laboratory to replicate alveolar bone, periodontal ligament, and grade I, II, and III furcation lesions. Cone-beam computed tomography scans were obtained with and without the MAR tool, and the furcation lesions were evaluated considering a 5-point Likert scale. Data were analyzed at 5%. RESULTS In the control group, there was no influence of MAR (P > .05); grade II lesions were not diagnosed, and grade III lesions were the most detected (P < .05). In the metal post group with MAR, grade III lesions were diagnosed more frequently than I and II (P < .05) and grade III without MAR (P < .05). In the fiberglass post group, the diagnosis of grade I lesions decreased with MAR (P < .05), and without MAR, grade III was most diagnosed (P < .05); grade III lesions were the most diagnosed (P < .05). CONCLUSIONS The MAR tool was only effective for diagnosing grade III furcation lesions, regardless of the intracanal material. Its application for grade I and II lesions did not contribute to improved diagnosis. Furthermore, in the fiberglass post group with grade I lesions, the MAR tool negatively affected the detection of the lesions.
Collapse
Affiliation(s)
- Mayara Fidelis Bastos
- Department of Pathology and Oral Diagnosis, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Maria Augusta Visconti
- Department of Pathology and Oral Diagnosis, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Rafael Rocha Pinto
- Department of Pathology and Oral Diagnosis, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Rafael Binato Junqueira
- Department of Dentistry, Federal University of Juiz de Fora/GV Campus, Governador Valadares, Brazil
| | | |
Collapse
|
4
|
de Oliveira Reis L, Santos-Corvini JPA, Gaêta-Araujo H, Sampaio-Oliveira M, Oliveira ML, Freitas DQ. Do voxel size and filter application on CBCT images improve the diagnosis of condylar morphological alterations? An ex vivo study. J Oral Rehabil 2024; 51:517-525. [PMID: 37941125 DOI: 10.1111/joor.13615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 07/11/2023] [Accepted: 10/19/2023] [Indexed: 11/10/2023]
Abstract
BACKGROUND There is no established protocol for the low doses of cone-beam computed tomography (CBCT) acquisition and filter application on the diagnosis of condylar morphological alterations. OBJECTIVES The objective of the study was to evaluate the influence of voxel size and filter application on the diagnosis of condylar morphological alterations in CBCT using an ex vivo model. METHODS CBCT scans of 36 temporomandibular joints were acquired using OP300 Maxio with voxel sizes of 0.085, 0.125 and 0.280 mm. Three radiologists evaluated the condyles in the CBCT volumes under three filter modes: no filter, '1x' sharpen filter and '2x' sharpen filter. The area under the ROC curve, sensitivity and specificity were calculated by comparing the evaluators' responses with the reference standard and compared among experimental groups using analysis of variance (ANOVA) (α = 5%). RESULTS The area under the ROC curve, sensitivity and specificity were not affected by voxel size and filter application (p > .05). For osteophyte and flattening, there were more true-positive responses in smaller voxel size. For erosion, the increase of true- and false-positive responses occurred with a larger voxel size. Overall, there was a tendency to decrease true positives for osteophyte and erosion and increase false positives for flattening with the '2x' sharpen filter. CONCLUSIONS The diagnosis of condylar morphological alterations assessed in this ex vivo analysis is not influenced by the voxel size and the application of the filters. However, attention is needed with the occurrence of false-positive diagnosis with a larger voxel size for erosion and '2x' sharpen filter for flattening.
Collapse
Affiliation(s)
- Larissa de Oliveira Reis
- Department of Dentistry, Federal University of Juiz de Fora Campus Governador Valadares (UFJF-GV), Governador Valadares, Minas Gerais, Brazil
| | | | - Hugo Gaêta-Araujo
- Department of Stomatology, Public Oral Health and Forensic Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil
| | - Matheus Sampaio-Oliveira
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Matheus L Oliveira
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil
| |
Collapse
|
5
|
Kolsuz ME, Evli C, Aksoy U, Koohnavard M, Aksoy S, Orhan K. Influence of voxel size and filter type on detecting vertical root fracture using cone-beam computed tomography. AUST ENDOD J 2023; 49 Suppl 1:439-446. [PMID: 37133318 DOI: 10.1111/aej.12761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/25/2023] [Accepted: 04/17/2023] [Indexed: 05/04/2023]
Abstract
Vertical root fractures (VRFs) can start at any level of the root and progress longitudinally to the coronal attachment. This study aimed to investigate the effects of different exposure parameters used when obtaining CBCT scans in detecting simulated VRFs. Hence, 80 intact human mandibular single-rooted pre-molar teeth without root fractures were included in the study. No statistically significant difference was found between the filters in terms of VRF detection in the group with the roots with only root canal filling (Groups 1 and 5); however, 100 voxels were found to be more successful in terms of VRF detection than other voxel sizes. Results of this study suggest that using lower voxel sizes leads to an accurate diagnosis of vertical root fracture, in addition, our results revealed that using AR filters did not improve the diagnostic accuracy in detecting VRFs.
Collapse
Affiliation(s)
- Mehmet Eray Kolsuz
- Department of Dentomaxillofacial Radiology, Ankara University, Ankara, Turkey
| | - Cengiz Evli
- Department of Dentomaxillofacial Radiology, Ankara University, Ankara, Turkey
| | - Umut Aksoy
- Department of Endodontics, Faculty of Dentistry, Near East University, Nicosia, Cyprus
| | | | - Seçil Aksoy
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Near East University, Nicosia, Cyprus
| | - Kaan Orhan
- Department of Dentomaxillofacial Radiology, Ankara University, Ankara, Turkey
- Department of Dental and Maxillofacial Radiodiagnostics, Medical University of Lublin, Lublin, Poland
- Ankara University Medical Design Application and Research Center (MEDITAM), Ankara, Turkey
| |
Collapse
|
6
|
Asnaashari M, Sadeghipour M, Bahrani Z, Valizadeh S, Moshfeghi M. The Effect of Changes in the Angular Position of Implants on Metal Artifact Reduction in Cone-Beam Computed Tomography Images: A Scoping Review. Radiol Res Pract 2023; 2023:5539719. [PMID: 37554657 PMCID: PMC10406552 DOI: 10.1155/2023/5539719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 07/07/2023] [Accepted: 07/20/2023] [Indexed: 08/10/2023] Open
Abstract
OBJECTIVE Dental implant artifacts can compromise the quality of cone-beam computed tomography (CBCT) scans and challenge radiographic detection in surrounding regions. This literature review was conducted to examine the impact of implant angle modification on reducing metal artifacts in CBCT scans. MATERIALS AND METHODS A scoping review of literature was carried out in PubMed, Embase, Scopus, and Cochrane databases. RESULTS Different spatial planes, including alpha, beta, gamma, and phi, along with 0°, 5.2°, 9.8°, 14.5°, 15°, 30°, 45°, 60°, 75°, and 90° angles were studied. Changes in the angular position of implants may reduce metal artifacts and improve the quality of CBCT scans. CONCLUSIONS Rotating implants within the alpha plane and angling them at 90° in the alpha plane enables reducing dental implant artifacts.
Collapse
Affiliation(s)
- Maedeh Asnaashari
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maryam Sadeghipour
- Department of Community Oral Health, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Zeinab Bahrani
- Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Solmaz Valizadeh
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mahkameh Moshfeghi
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
Nomier AS, Gaweesh YSED, Taalab MR, El Sadat SA. Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study. BMC Oral Health 2022; 22:615. [PMID: 36528573 PMCID: PMC9759909 DOI: 10.1186/s12903-022-02663-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Early accurate radiographic assessment of peri-implant bone condition is highly important to avoid excessive loss of supporting bone and implant failure. Cone beam computed tomography (CBCT) is the radiographic technique of choice if peri-implant dehiscence and fenestration defects are suspected. The higher radiation dose and the presence of beam hardening artifacts are the main drawbacks of CBCT imaging techniques. This study aims to evaluate the influence of low-dose cone beam computed tomography (LD-CBCT) and metal artifact reduction (MAR) tool on the assessment of peri-implant dehiscence and fenestration. METHODOLOGY Thirty titanium implants were inserted into bovine rib blocks. Twenty had standardized bone defects (10 with dehiscence and 10 with fenestration), while the remaining 10 were used as control group with no defects. Radiographic examinations held with high-definition CBCT (HD-CBCT) and LD-CBCT with and without application of MAR tool. Images were assessed by four examiners for the presence or absence of peri-implant defects. The area under the area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, specificity, and accuracy were calculated for all radiographic protocols. RESULTS In the absence of MAR tool, there was no difference in AUC and diagnostic values between LD-CBCT and HD-CBCT for detection of both defects. When the MAR tool was applied, the AUC values, sensitivity, and accuracy were higher in HD-CBCT than in LD-CBCT for the detection of both defects, especially for the dehiscence, while specificity remained the same. CONCLUSION LD-CBCT can be used in the evaluation of peri-implant dehiscence and fenestration without any decrease in diagnostic accuracy. The application of MAR tool decrease the diagnostic ability of both defects, especially for the detection of dehiscence defects.
Collapse
Affiliation(s)
- Alaa Shafiek Nomier
- grid.7155.60000 0001 2260 6941Department of Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology, Faculty of Dentistry, Alexandria University, Champolion St. Azarita, Alexandria, 21521 Egypt
| | - Yousria Salah El-Din Gaweesh
- grid.7155.60000 0001 2260 6941Department of Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology, Faculty of Dentistry, Alexandria University, Champolion St. Azarita, Alexandria, 21521 Egypt
| | - Maha R. Taalab
- grid.7155.60000 0001 2260 6941Department of Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology, Faculty of Dentistry, Alexandria University, Champolion St. Azarita, Alexandria, 21521 Egypt
| | - Shaimaa Abu El Sadat
- grid.7269.a0000 0004 0621 1570Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ain-Shams University, Cairo, Egypt
| |
Collapse
|
8
|
Chagas MM, Kobayashi-Velasco S, Gimenez T, Cavalcanti MGP. Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis. Imaging Sci Dent 2022; 51:363-372. [PMID: 34987996 PMCID: PMC8695475 DOI: 10.5624/isd.20210120] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 09/08/2021] [Accepted: 09/24/2021] [Indexed: 12/21/2022] Open
Abstract
Purpose This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. Materials and Methods Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. Results The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects (0.73) and fenestration defects (0.87) showed a statistically significant difference. Conclusion The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.
Collapse
Affiliation(s)
- Mariana Murai Chagas
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | | - Thais Gimenez
- Graduate Program in Dentistry, Ibirapuera University, São Paulo, São Paulo, Brazil
| | | |
Collapse
|
9
|
Fontenele RC, Nascimento EHL, Imbelloni-Vasconcelos AC, Martins LAC, Pontual ADA, Ramos-Perez FMM, Freitas DQ. Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants. Imaging Sci Dent 2022; 52:267-273. [PMID: 36238703 PMCID: PMC9530290 DOI: 10.5624/isd.20220040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Revised: 05/07/2022] [Accepted: 05/24/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study was to assess the influence of kilovoltage-peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values (P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.
Collapse
Affiliation(s)
- Rocharles Cavalcante Fontenele
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | | | | | - Luciano Augusto Cano Martins
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Andrea dos Anjos Pontual
- Department of Clinical and Preventive Dentistry, Division of Oral Radiology, Federal University of Pernambuco, Recife, PE, Brazil
| | - Flávia Maria Moraes Ramos-Perez
- Department of Clinical and Preventive Dentistry, Division of Oral Radiology, Federal University of Pernambuco, Recife, PE, Brazil
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
10
|
Bagis N, Kurt MH, Evli C, Camgoz M, Atakan C, Peker Ozturk H, Orhan K. Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study. Oral Radiol 2021; 38:325-335. [PMID: 34387842 DOI: 10.1007/s11282-021-00561-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 08/03/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The aim of this study is to assess the effects of metal artifact reduction (MAR) and adaptive image noise enhancer (AINO) in CBCT imaging on the detection accuracy of artificially created fenestration defects in proximity to titanium and zirconium implants in sheep jaw. METHODS Six zirconium and 10 titanium implants were planted on mandibular jaws of three sheep, and artificial defects were created. All images were obtained with a standard voxel size (0.150 mm3) and with 4 scan modes: (1) without MAR/without AINO; (2) with MAR/without AINO; (3) without MAR/with AINO; and (4) with MAR/with AINO during CBCT scanning. A total of 60 CBCT scans were produced. RESULTS For all types of implants, intra- and inter-observer kappa values were the highest for MAR filter. The scan mode of with MAR filter was found to have the highest area under the curve (AUC), whereas the scan mode of without both MAR and AINO filters was found to have the lowest AUC values with statistical significance (p ≤ 0.05). Titanium implants were found to have higher AUC values than zirconium (p ≤ 0.05). CONCLUSION Both MAR module and AINO filters enhance the accuracy of the detection of peri-implant fenestrations; however, the use of MAR filter solely can be recommended for detection of peri-implant fenestrations.
Collapse
Affiliation(s)
- Nilsun Bagis
- Department of Periodontology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Mehmet Hakan Kurt
- Department of Dentoaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.
| | - Cengiz Evli
- Department of Dentoaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Melike Camgoz
- Department of Periodontology, Faculty of Dentistry, Gazi University, Ankara, Turkey
| | - Cemal Atakan
- Department of Statistics, Faculty of Science, Ankara University, Ankara, Turkey
| | - Hilal Peker Ozturk
- Department of Dentomaxillofacial Radiology, Gulhane Faculty of Dentistry, University of Health Sciences, Ankara, Turkey
| | - Kaan Orhan
- Department of Dentoaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.,Ankara University Medical Design Application and Research Center (MEDITAM), Ankara, Turkey
| |
Collapse
|
11
|
Evaluation of streak metal artifacts in cone beam computed tomography by using the Gumbel distribution: a phantom study. Oral Surg Oral Med Oral Pathol Oral Radiol 2020; 131:494-502. [PMID: 33020029 DOI: 10.1016/j.oooo.2020.08.031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 07/11/2020] [Accepted: 08/15/2020] [Indexed: 12/14/2022]
Abstract
OBJECTIVE The aim of this study was to confirm whether streak metal artifacts (SMAs) between titanium implants on cone beam computed tomography (CBCT) images could be evaluated by using the Gumbel distribution (GD). Moreover, the influence of different scan settings on SMAs was investigated. STUDY DESIGN An iodine solution simulating dentin was placed between 2 titanium rods in an acrylic phantom. It was scanned by using CBCT at 2 settings with nearly equivalent exposure doses (90 kV, 7 mA; 78 kV, 10 mA). The images were analyzed, and the dependence of the voxel values in SMAs on GD was investigated with the coefficient of determination (r2). The location parameters, indicating the strength of the SMAs, were calculated for each scan setting and evaluated with the Mann-Whitney U test. Significance was established at p = .05. RESULTS The SMAs on CBCT images depended on GD (r2 ≥ .959). The SMAs with the 78 kV, 10 mA settings were significantly smaller than those with the 90 kV, 7 mA settings (p < .01). CONCLUSIONS SMAs on CBCT images could be evaluated by using methods based on GD. The strengths of metal artifacts varied with changes in scan settings, even at nearly equivalent exposure doses.
Collapse
|
12
|
Kurt MH, Bağış N, Evli C, Atakan C, Orhan K. Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study. Int J Implant Dent 2020; 6:58. [PMID: 33006000 PMCID: PMC7530157 DOI: 10.1186/s40729-020-00254-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Accepted: 08/27/2020] [Indexed: 11/10/2022] Open
Abstract
Background To examine the influence of voxel sizes to detect of peri-implant fenestration defects on cone beam computed tomography (CBCT) images. Materials and methods This study performed with three sheep heads both maxilla and mandible and two types of dental implant type 1 zirconium implant (Zr40) (n = 6) and type 2 titanium implant (Ti22) (n = 10). A total of 14 peri-implant fenestrations (8 buccal surfaces, 6 palatal/lingual surface) were created while 18 surfaces (8 buccal, 10 palatal/lingual) were free of fenestrations. Three observers have evaluated the images of fenestration at each site. Images obtained with 0.75 mm3, 0.100 mm3, 0.150 mm3, 0.200 mm3, and 0.400 mm3 voxel sizes. For intra- and inter-observer agreements for each voxel size, Kappa coefficients were calculated. Results Intra- and inter-observer kappa values were the highest for 0.150 mm3, and the lowest in 0.75 mm3 and 0.400 mm3 voxel sizes for all types of implants. The highest area under the curve (AUC) values were found higher for the scan mode of 0.150 mm3, whereas lower AUC values were found for the voxel size for 0.400 mm3. Titanium implants had higher AUC values than zirconium with the statistical significance for all voxel sizes (p ≤ 0.05). Conclusion A voxel size of 0.150 mm3 can be used to detect peri-implant fenestration bone defects. CBCT is the most reliable diagnostic tool for peri-implant fenestration bone defects.
Collapse
Affiliation(s)
- Mehmet Hakan Kurt
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.
| | - Nilsun Bağış
- Dentistry Department of Periodontology, Ankara University, Ankara, Turkey
| | - Cengiz Evli
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Cemal Atakan
- Faculty of Science Department of Statistics, Ankara University, Ankara, Turkey
| | - Kaan Orhan
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.,Medical Design Application and Research Center (MEDITAM), Ankara University, Ankara, Turkey
| |
Collapse
|