Gras A, Wiklund M, Ferreira A, Chapus V, Dunet J, Rochcongar G, Hulet C. Results of third generation dual mobility total hip arthroplasties with non-cross-linked polyethylene in patients under 60 years of age: comparative study of full pressfit vs. tripod cups after 8.6 years. Orthop Traumatol Surg Res 2024; 110:103934. [PMID: 38991889 DOI: 10.1016/j.otsr.2024.103934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 03/14/2024] [Accepted: 03/26/2024] [Indexed: 07/13/2024]
Abstract
BACKGROUND The concept of dual mobility of total hip arthroplasties (THA) is a revolution in the prevention of dislocations and in the treatment of instability. Its use remains controversial in patients under 60 years old, providing poorer results with first generation cups coated with alumina. This study, carried out on modern dual mobility (DM) cups with a porous bilayer coating, in active patients under 60 years of age aimed to evaluate: (1) the mechanical survival of two latest generation DM THA, with failure defined as revision of acetabular or femoral implants for mechanical loosening, by comparing a tripod cup to a full pressfit cup, (2) to evaluate the complications, (3) to compare the rate of radiographic peri-prosthetic osteolysis between the 2 implants. HYPOTHESIS The hypothesis was that the medium-term survival of modern DM cups placed in young patients was the same regardless of the type of acetabular fixation used. MATERIALS AND METHODS This was a retrospective study of 119 latest generation DM THA with standard polyethylene, composed of 66 full pressfit cups and 53 tripod fixation cups, used in primary arthroplasty in 111 patients between 2005 and 2016. The survival study was carried out using medical records. The clinical evaluation was carried out using the modified Harris Hip Score (mHHS) as well as the self-administered Hip and Osteoarthritis Outcome Score (HOOS) and Oxford-12 questionnaires. Radiological analysis was carried out on radiographs looking for bone demineralization and acetabular and femoral lines. RESULTS At 8.6 years (5-16), no revision for mechanical loosening was observed regardless of the type of cup. The prosthesis dislocation rate (large joint) was 1.7%: 1 case in each group (p = 1), including one revision required in the full pressfit group. Three revisions for mechanical complications were recorded: a recurrent dislocating hip on a full pressfit cup that was not sufficiently anteverted, an acetabular peri-prosthetic fracture on a full pressfit cup and a case of iliopsoas impingement with a retroverted tripod cup. The survival rate for all-cause revision was 93.8% for pressfit (95% CI: 88.2%-99.9%) vs. 96.2% for tripod (95% CI: 91.1%-100%) (p = 0.63) and for revision due to any cause excluding infection, 96.9% for pressfit (95% CI: 92.8%-100%) vs. 98.1% for tripod (95% CI: 94.4%-100%) (p = 0.7). The rate of periacetabular osteolysis was 11%, significantly more present amongst tripod cups (24%, 9 cases) compared to full pressfit cups (2%, 1 case) (p < 0.01). CONCLUSION This series demonstrates good performance of 3rd generation DM cups with porous bilayer coating in patients under 60 years of age regardless of the type of acetabular fixation, at 8.6 years of follow-up. The rate of osteolysis around full pressfit cups remains very low, unlike that of tripod cups. The use of Double Mobility prostheses for primary hip osteoarthritis is possible in young patients, preferably with full pressfit cups (i.e., without any pegs or additional screws that may promote diffusion of polyethylene debris and osteolysis). LEVEL OF EVIDENCE III; comparative retrospective study.
Collapse
Affiliation(s)
- Arthur Gras
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France.
| | - Marianne Wiklund
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France
| | - Alexandre Ferreira
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France
| | - Valentin Chapus
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France
| | - Julien Dunet
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France
| | - Goulven Rochcongar
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France
| | - Christophe Hulet
- Département de Chirurgie Orthopédique du CHU de Caen Unité Inserm Comete 1075, Av. de la Côte de Nacre, 14000 Caen, France
| |
Collapse
|
2
|
Hidayat T, Ismail R, Tauviqirrahman M, Saputra E, Ammarullah MI, Lamura MDP, Bayuseno AP, Jamari. Running-in behavior of dual-mobility cup during the gait cycle: A finite element analysis. Proc Inst Mech Eng H 2024; 238:99-111. [PMID: 38156402 DOI: 10.1177/09544119231216023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2023]
Abstract
The running-in process is considered an essential aspect of the comprehensive wear process. The phenomenon of running-in occurs during the initial stages of wear in the prosthetic hip joint. Within the field of tribology, the running-in phenomenon of the hip joint pertains to the mechanism by which the contact surfaces of the artificial hip joint components are adjusted and a suitable lubricating film is formed. During the process of hip joint running-in, there is an interaction between the metal surface of the ball and the joint cup, which results in adjustments being made until a steady state is achieved. The achievement of desirable wear existence and reliable performance of artificial hip joint components are reliant upon the tribological running-in of the hip joint. Despite the establishment of current modeling approaches, there remains a significant lack of understanding concerning running-in wear, particularly the metal-on-polyethylene (MoP) articulations in dual-mobility cups (DMC). An essential aspect to consider is the running-in phase of the dual mobility component. The present study employed finite element analysis to investigate the running-in behavior of dual mobility cups, wherein femoral head components were matched with polyethylene liners of varying thicknesses. The analysis of the running-in phase was conducted during the normal gait cycle. The results of this investigation may be utilized to design a dual-mobility prosthetic hip joint that exhibits minimal running-in wear.
Collapse
Affiliation(s)
- Taufiq Hidayat
- Department of Mechanical Engineering, Diponegoro University, Semarang, Central Java, Indonesia
- Department of Mechanical Engineering, Universitas Muria Kudus, Kudus, Central Java, Indonesia
| | - Rifky Ismail
- Department of Mechanical Engineering, Diponegoro University, Semarang, Central Java, Indonesia
- Center for Biomechanics Biomaterials Biomechatronics and Biosignal Processing (CBIOM3S) Diponegoro University, Semarang, Central Java, Indonesia
| | - Mohammad Tauviqirrahman
- Department of Mechanical Engineering, Diponegoro University, Semarang, Central Java, Indonesia
| | - Eko Saputra
- Department of Mechanical Engineering, Semarang State Polytechnic, Semarang, Central Java, Indonesia
| | - Muhammad Imam Ammarullah
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung, West Java, Indonesia
| | - M Danny Pratama Lamura
- Department of Mechanical Engineering, Diponegoro University, Semarang, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre (UBM-ERC), Diponegoro University, Semarang, Central Java, Indonesia
| | | | - Jamari
- Department of Mechanical Engineering, Diponegoro University, Semarang, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre (UBM-ERC), Diponegoro University, Semarang, Central Java, Indonesia
| |
Collapse
|
3
|
Butler JT, Stegelmann SD, Butler JL, Bullock M, M Miller R. Comparing dislocation rates by approach following elective primary dual mobility total hip arthroplasty: a systematic review. J Orthop Surg Res 2023; 18:226. [PMID: 36945061 PMCID: PMC10032016 DOI: 10.1186/s13018-023-03724-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 03/16/2023] [Indexed: 03/23/2023] Open
Abstract
BACKGROUND Dual mobility components can be implanted during total hip arthroplasty (THA) for primary osteoarthritis via a direct anterior approach (DAA), anterolateral approach (ALA), direct lateral approach (DLA), or posterior/posterolateral approach (PLA). This review compares dual mobility hip dislocation rates using these approaches for elective primary THA. METHODS PubMed, Embase, and Cochrane databases were systematically searched for articles published after January 1, 2006 that reported dislocation rates for adult patients after primary THA with dual mobility implants. Articles were excluded if they reported revision procedures, nonelective THA for femoral neck fractures, acetabular defects requiring supplemental implants, prior surgery, or ≤ 5 patients. The primary outcome was hip dislocation rate. Secondary outcomes included infection, Harris Hip Score (HHS), and Postel-Merle d'Aubigné (PMA) score. RESULTS After screening 542 articles, 63 met inclusion criteria. Due to study heterogeneity, we did not perform a meta-analysis. Eight studies reported DAA, 5 reported ALA, 6 reported the DLA, and 56 reported PLA. Study size ranged from 41 to 2,601 patients. Mean follow-up time ranged from 6 months to 25 years. Rates of infection and dislocation were low; 80% of ALA, 87.5% of DAA, 100% of DLA, and 82.1% of PLA studies reported zero postoperative dislocations. Studies reporting postoperative HHS and PMA scores showed considerable improvement for all approaches. CONCLUSIONS Patients undergoing primary THA with dual mobility implants rarely experience postoperative dislocation, regardless of surgical approach. Additional studies directly comparing DAA, ALA, DLA, and PLA are needed to confirm these findings.
Collapse
Affiliation(s)
- Justin T Butler
- Department of Orthopedic Surgery, Mercy Health St. Vincent Medical Center, 2409 Cherry St, Suite #10, Toledo, OH, 43608, USA.
| | - Samuel D Stegelmann
- Department of Orthopedic Surgery, Mercy Health St. Vincent Medical Center, 2409 Cherry St, Suite #10, Toledo, OH, 43608, USA
| | - Johnathon L Butler
- Department of Orthopedic Surgery, Mercy Health St. Vincent Medical Center, 2409 Cherry St, Suite #10, Toledo, OH, 43608, USA
| | - Matthew Bullock
- Department of Orthopedic Surgery, Marshall University Joan C. Edwards School of Medicine, Huntington, WV, USA
| | - Richard M Miller
- Department of Orthopedic Surgery, Mercy Health St. Vincent Medical Center, 2409 Cherry St, Suite #10, Toledo, OH, 43608, USA
| |
Collapse
|
4
|
Ciolli G, Mesnard G, Deroche E, Gunst S, Batailler C, Servien E, Lustig S. Is Cemented Dual-Mobility Cup a Reliable Option in Primary and Revision Total Hip Arthroplasty: A Systematic Review. J Pers Med 2022; 13:jpm13010081. [PMID: 36675742 PMCID: PMC9867154 DOI: 10.3390/jpm13010081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/22/2022] [Accepted: 12/25/2022] [Indexed: 12/31/2022] Open
Abstract
Background: Instability is a common complication following total hip arthroplasty (THA). The dual mobility cup (DMC) allows a reduction in the dislocation rate. The goal of this systematic review was to clarify the different uses and outcomes according to the indications of the cemented DMC (C-DMC). Methods: A systematic review was performed using the keywords "Cemented Dual Mobility Cup" or "Cemented Tripolar Cup" without a publication year limit. Of the 465 studies identified, only 56 were eligible for the study. Results: The overall number of C-DMC was 3452 in 3426 patients. The mean follow-up was 45.9 months (range 12-98.4). In most of the cases (74.5%) C-DMC was used in a revision setting. In 57.5% DMC was cemented directly into the bone, in 39.6% into an acetabular reinforcement and in 3.2% into a pre-existing cup. The overall dislocation rate was 2.9%. The most frequent postoperative complications were periprosthetic infections (2%); aseptic loosening (1.1%) and mechanical failure (0.5%). The overall revision rate was 4.4%. The average survival rate of C-DMC at the last follow-up was 93.5%. Conclusions: C-DMC represents an effective treatment option to limit the risk of dislocations and complications for both primary and revision surgery. C-DMC has good clinical outcomes and a low complication rate.
Collapse
Affiliation(s)
- Gianluca Ciolli
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
- Orthopaedics and Traumatology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Sacred Heart Catholic University, 00168 Rome, Italy
| | - Guillaume Mesnard
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
- Correspondence:
| | - Etienne Deroche
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
| | - Stanislas Gunst
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFST-TAR, LBMC UMR_T9406, 69622 Lyon, France
| | - Cécile Batailler
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFST-TAR, LBMC UMR_T9406, 69622 Lyon, France
| | - Elvire Servien
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
- LIBM—EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, 69622 Lyon, France
| | - Sébastien Lustig
- Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFST-TAR, LBMC UMR_T9406, 69622 Lyon, France
| |
Collapse
|
5
|
Aguado-Maestro I, de Blas-Sanz I, Sanz-Peñas AE, Campesino-Nieto SV, Diez-Rodríguez J, Valle-López S, Espinel-Riol A, Fernández-Díez D, García-Alonso M. Dual Mobility Cups as the Routine Choice in Total Hip Arthroplasty. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:528. [PMID: 35454367 PMCID: PMC9029134 DOI: 10.3390/medicina58040528] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 04/02/2022] [Accepted: 04/07/2022] [Indexed: 11/17/2022]
Abstract
Background and Objectives: Total hip arthroplasty (THA) is considered the most successful surgical procedure in orthopedics. However, dislocation remains the main indication for surgical revision. New designs of dual mobility cups (DMC) have lowered the classical complications and have extended the indications of DMC in elective surgeries. Our aim is to assess the trend of DMC indications in THA as well as the incidence of their dislocation. Materials and Methods: We retrospectively reviewed all patients undergoing THA with DMC during the years 2015 and 2021. The original indication for DMC included patients sustaining neck of femur fractures (NOF#) and associated risk factors for dislocations. Five years later, DMC was considered our standard of care in total hip arthroplasty. The approach (anterolateral or posterolateral) was chosen by the surgeon according to his/her preferences, as was the implant. Data collected included patients' demographics, diagnosis, admission time, surgical approach, cup models, and inclination and complications. Patients sustaining a hip dislocation were prospectively reviewed and assessed for treatment received, new dislocations, and need for surgical revision. Two groups were created for the analysis according to the presence or absence of dislocation during follow-up. Results: In the analysis, 531 arthroplasties were included (mean age 72.2 years) with a mean follow-up of 2.86 years. The trend of indications for DMC increased from 16% of THA in 2015 to 78% of THA in 2021. We found a total of 8 dislocations (1.5%), none of them associated with elective surgery. Closed reduction was unsatisfactory in four cases (50%). There was one case of intraprosthetic dislocation. Dislocations were associated to smaller heads (22 mm) (1.5% vs. 25%, p = 0.008) and cups (51.2 mm vs. 48.7 mm, p = 0.038) and posterior approach (62.5% vs. 37.5%, p = 0.011). Conclusion: Dual mobility cups are a great option to reduce the risk of dislocation after a THA both in the neck of femur fractures and elective cases. The use of an anterolateral approach in THA after a neck or femur fracture might considerably decrease the risk of dislocation.
Collapse
Affiliation(s)
- Ignacio Aguado-Maestro
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Inés de Blas-Sanz
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Ana Elena Sanz-Peñas
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Silvia Virginia Campesino-Nieto
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Jesús Diez-Rodríguez
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Sergio Valle-López
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Alberto Espinel-Riol
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| | - Diego Fernández-Díez
- Department of Traumatology and Orthopaedic Surgery, Infanta Sofía University Hospital, 28703 Madrid, Spain;
| | - Manuel García-Alonso
- Department of Traumatology and Orthopaedic Surgery, Río Hortega University Hospital, 47012 Valladolid, Spain; (I.d.B.-S.); (A.E.S.-P.); (S.V.C.-N.); (J.D.-R.); (S.V.-L.); (A.E.-R.); (M.G.-A.)
| |
Collapse
|
6
|
Kanniyan K, Patil S, Kumar PSA, Suryanarayan P, Bose VC. Does the Femoral Head Size Influence Outcomes After Uncemented Total Hip Arthroplasty for Fused Hips? A Prospective Study in Ankylosing Spondylitis. Indian J Orthop 2020; 54:831-839. [PMID: 33133406 PMCID: PMC7573063 DOI: 10.1007/s43465-020-00210-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 07/21/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND Uncemented total hip arthroplasty (THA) with large size femoral heads have shown greater advantage with good stability, range of motion and decreased dislocation rate in ankylosing spondylitis (AS). Meticulous planning is needed to address the unique surgical challenges in such patients with fused hip and spinal deformity. MATERIALS AND METHODS Thirty fivefused hip joints in twenty-five AS patients who underwent uncemented THA (April 2014 to December 2016) were included in our prospective study and were followed up for a minimum period of 36 months. Pain relief, functional improvement and patient satisfaction were statistically assessed using "Visual Analogue Score" (VAS), "Harris Hip Score" (HHS) and "AJRI 10-Point Satisfaction Score" (A10PSS), respectively. RESULTS The overall mean preoperative VAS improved from 6.9 ± 1.5 to 1.5 ± 1, HHS improved from 50.0 ± 12 to 88.4 ± 7.8 and A10PSS improved from 2.2 ± 1.2 to 7.6 ± 0.8. Our study results were significant with zero dislocation and good functional score in comparison to the other available studies in literature. First subdivision study in AS patients with bilateral THA performed better than unilateral THA. Second subdivision study showed no significant statistical difference in terms of VAS, HHS, A10PSS and dislocation rate in relation to femoral head size between 32 mm, 36 mm and 40 mm. CONCLUSION Uncemented THA with large size femoral head equal or greater than 32 mm provides better stability and good functional outcome with less dislocation rate in comparison to older studies of literature with femoral head size less than 32 mm. LEVEL OF EVIDENCE A Level II study. (Data collected from the ongoing prospective study) (https://www.spine.org/Documents/LevelsofEvidenceFinal.pdf).
Collapse
Affiliation(s)
- Kalaivanan Kanniyan
- Asian Joint Reconstruction Institute (AJRI), SIMS Hospitals, Chennai, Tamil Nadu India
| | - Shantanu Patil
- Translational Medicine and Research, SRM Medical College, SRM IST, Kattankulathur, Tamil Nadu India
| | - P. S. Ashok Kumar
- Asian Joint Reconstruction Institute (AJRI), SIMS Hospitals, Chennai, Tamil Nadu India
| | - P. Suryanarayan
- Asian Joint Reconstruction Institute (AJRI), SIMS Hospitals, Chennai, Tamil Nadu India
| | - Vijay C. Bose
- Asian Joint Reconstruction Institute (AJRI), SIMS Hospitals, Chennai, Tamil Nadu India
| |
Collapse
|
7
|
Chouteau J, Rollier JC, Bonnin MP, Saffarini M, Nover L, Chatelet JC, Jacquot L. Absence of instabilities and intra-prosthetic dislocations at 7 to 11 years following THA using a fourth-generation cementless dual mobility acetabular cup. J Exp Orthop 2020; 7:51. [PMID: 32661747 PMCID: PMC7359208 DOI: 10.1186/s40634-020-00265-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 06/16/2020] [Indexed: 12/23/2022] Open
Abstract
PURPOSE Dual-mobility (DM) cups are increasingly used in total hip arthroplasty (THA) but there lacks literature on their long-term results. We aimed to investigate outcomes of a fourth-generation cementless DM acetabular cup at 7-11 years. METHODS We retrospectively evaluated 240 consecutive hips that received cementless THA using the same dual mobility cup (Novae Sunfit TH) and femoral stem (Corail). Patients were recalled at ≥7 years to collect Oxford hip scores (OHS), Harris hip scores (HHS), and inspect for radiolucent lines and granulomas. Multi-variable analyses were performed to determine whether HHS or OHS were associated with pre- or intra-operative variables. RESULTS At 8.4 ± 0.8 years (range, 7-11), 6 hips were revised (2.5%), 54 deceased (22.5%), and 14 could not be reached (5.8%). Four revisions (2 cup+stem, 2 liners only) were due to sepsis (1.7%), one (cup and stem) for trauma (0.4%), and one (stem) due to aseptic loosening (0.4%). For the remaining 166 hips, HHS was 83.6 ± 13.2 and OHS was 20.3 ± 6.7. Multi-variable analysis confirmed that HHS (β = - 0.38; p = 0.039) and OHS (β = 0.36; p < 0.001) worsened with age, and that OHS was worse for Charnley C patients (β = 3.17; p = 0.009). Neither granulomas nor radiolucenies were observed around any cups, but radiolucenies were seen around 25 stems (20.3%). CONCLUSIONS This fourth-generation DM cup demonstrated satisfactory outcomes at 7-11 years, with no instabilities or cup revisions due to aseptic loosening. Better OHS was observed for younger patients and those presenting higher Charnley grade. LEVEL OF EVIDENCE Level IV, retrospective case study.
Collapse
Affiliation(s)
- Julien Chouteau
- Artro Group Institute, Lyon, France.,Clinique d'Argonay, Ramsay Santé, Annecy, France
| | - Jean-Charles Rollier
- Artro Group Institute, Lyon, France.,Clinique d'Argonay, Ramsay Santé, Annecy, France
| | - Michel P Bonnin
- Artro Group Institute, Lyon, France.,Centre Orthopédique Santy, Hôpital Privé Jean Mermoz, Ramsay Santé, Lyon, France
| | | | | | - Jean-Christophe Chatelet
- Artro Group Institute, Lyon, France.,Centre de Chirurgie Orthopédique du Beaujolais, Ramsay Santé, Arnas, France
| | - Laurent Jacquot
- Artro Group Institute, Lyon, France.,Clinique d'Argonay, Ramsay Santé, Annecy, France
| |
Collapse
|
8
|
Caron E, Migaud H, Pasquier G, Girard J, Putman S. Prospective randomized study using EBRA-FCA to compare bone fixation between cementless SL-PLUS Zweymüller versus SL-PLUS MIA femoral implants in primary total hip arthroplasty with clinical assessment at a minimum 5years' follow-up. Orthop Traumatol Surg Res 2020; 106:519-525. [PMID: 32029409 DOI: 10.1016/j.otsr.2019.10.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 09/19/2019] [Accepted: 10/04/2019] [Indexed: 02/03/2023]
Abstract
INTRODUCTION Sometimes the slightest changes in implant design can lead to failure, even for a validated prosthesis. A minimally invasive cementless model, the SL-PLUS MIA™, in which the lateral shoulder is eliminated, was developed from the Zweymüller SL-PLUS™ implant. After satisfactory in-vitro tests, it required in-vivo assessment to ensure that bone fixation is good. We therefore conducted a prospective randomized study comparing the two versions of the Zweymüller femoral stem, with the aim of (1) comparing bone fixation up to 2 years' follow-up on EBRA-FCA radiography; and (2) assessing any difference in clinical or radiographic performance. HYPOTHESIS Primary stability assessed on EBRA-FCA does not significantly differ between the SL-PLUS MIA™ and SL-PLUS™ implants. PATIENTS AND METHOD A single-center multi-surgeon prospective randomized study included 80 patients (79 were operated on) between April 2009 and October 2012, with a mean 6 years' follow-up. Radiographic assessment used the EBRA-FCA application up to 2 years' follow-up; clinical assessment, with a minimum 5 years' follow-up, was performed by a single observer, using the Harris and Oxford-12 scores. The two groups, SL-PLUS™ (n=38) and SL-PLUS MIA™ (n=41), were comparable in gender, age, indications, body-mass index and preoperative functional status. RESULTS At a minimum 2 years' follow-up, 24 SL-PLUS™ and 27 SL-PLUS MIA™ implants were analyzed on EBRA-FCA. Mean migration was respectively -0.3mm±0.8 [range, -1.6 to 1.3] and -0.5mm±0.7 [range, -2.2 to 0.5] (p=0.21). There was likewise no significant difference in varus tilt. The number of ectopic ossifications did not differ, despite the absence of shoulder: 7 with SL-PLUS™ (23%), and 10 with SL-PLUS MIA™ (32%), without clinical impact. Oxford score improved from 43±6.8 to 19±7 at 5 years' follow-up with SL-PLUS ™ and from 44±8.8 to 20±7.4 with SL-PLUS MIA™: i.e., no significant inter-group difference. Likewise, Harris score at 2 years' follow-up did not differ: 91.6±8.7 and 89.7±10.2, respectively. Implant survival did not differ: SL-PLUS MIA™, 41/41 (100%); SL-PLUS™, 36/38 (94.7%) (p=0.13). CONCLUSION There was no significant difference in fixation quality between the SL-PLUS™ and SL-PLUS MIA™ implants. Elimination of the shoulder did not jeopardize primary or secondary fixation, but neither did it reduce the rate of ossification. The modified Zweymüller implant appeared risk-free at 6 years' follow-up. LEVEL OF EVIDENCE II, low-power prospective randomized study.
Collapse
Affiliation(s)
- Etienne Caron
- Université Lille Nord de France, 59000 Lille, France; Service d'Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France.
| | - Henri Migaud
- Université Lille Nord de France, 59000 Lille, France; Service d'Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France
| | - Gilles Pasquier
- Université Lille Nord de France, 59000 Lille, France; Service d'Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France
| | - Julien Girard
- Université Lille Nord de France, 59000 Lille, France; Service d'Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France
| | - Sophie Putman
- Université Lille Nord de France, 59000 Lille, France; Service d'Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France
| |
Collapse
|
9
|
Cypres A, Fiquet A, Girardin P, Fitch D, Bauchu P, Bonnard O, Noyer D, Roy C. Long-term outcomes of a dual-mobility cup and cementless triple-taper femoral stem combination in total hip replacement: a multicenter retrospective analysis. J Orthop Surg Res 2019; 14:376. [PMID: 31752951 PMCID: PMC6868773 DOI: 10.1186/s13018-019-1436-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2019] [Accepted: 10/29/2019] [Indexed: 01/21/2023] Open
Abstract
BACKGROUND The separate design concepts of dual-mobility cups and triple-taper femoral stems were developed to improve survivorship following total hip replacement (THR) by reducing instability/dislocation and enabling enhanced fixation. Successful outcomes at over two decades have been reported with earlier-generation devices based on these concepts. The current study aimed to provide the first long-term results with a unique pairing of later-generation dual-mobility cup and triple-taper cementless femoral stem after a decade of use in patients undergoing THR. METHODS In this retrospective analysis, records were reviewed for all subjects implanted with this dual-mobility cup/cementless femoral stem combination at three centers between 2002 and 2005. Any subject who had not already had follow-up visit beyond 10 years, was not previously revised, and still living were invited for a single follow-up visit consisting of Merle d'Aubgine Scores, the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, and standard radiographs. RESULTS There were 244 THRs available for analysis. At a mean follow-up of 11.9 years, the Kaplan-Meier survivorship (endpoint: revision for any reason) was 99.1% (95% CI, 97.6-99.7) for the stem and 95.9% (95% CI, 93.1-97.6) for the cup. Merle d'Aubigne Scores were significantly improved from baseline and WOMAC scores were in the satisfactory range at the final follow-up. Radiographic analysis revealed no cases of stem subsidence, no cases of bone hypertrophy, 1 (0.4%) case of bone atrophy, and 3 (1.2%) cases of osteolysis around the stem. No subjects had radiolucent lines greater than 1 mm in any femoral Gruen zone. Evidence of cup migration was seen in 1 (0.4%) subject and 1 (0.4%) subject had evidence of osteolysis that was seen in Gruen zones I, II, IV, and V. CONCLUSIONS This combination of a later-generation dual-mobility cup and cementless triple-taper stem was associated with excellent survivorship and satisfactory functional outcomes at over 10 years follow-up. TRIAL REGISTRATION ClinicalTrials.gov, NCT02648152. Date of registration: January 6, 2016. Retrospectively registered.
Collapse
Affiliation(s)
- Alain Cypres
- Clinique du Renaison, 75 Rue Général Giraud, 42300, Roanne, France.
| | | | | | | | | | | | - Daniel Noyer
- Hôpital de Bourgoin-Jallieu, Bourgoin-Jallieu, France
| | | |
Collapse
|
10
|
Is the position of dual-mobility cup in THA for femoral neck fractures optimal? A retrospective study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 30:275-280. [DOI: 10.1007/s00590-019-02576-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2019] [Accepted: 10/01/2019] [Indexed: 11/25/2022]
|
11
|
Early simultaneous bilateral total hip arthroplasty for the management of bilateral acetabular fracture in an elderly patient. Arthroplast Today 2019; 5:139-144. [PMID: 31286032 PMCID: PMC6588820 DOI: 10.1016/j.artd.2019.03.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 03/25/2019] [Accepted: 03/26/2019] [Indexed: 11/22/2022] Open
Abstract
Bilateral acetabular fractures in elderly patients due to seizures are very rare and management is a challenge. The standard treatment for acetabular fracture, open reduction with internal fixation, is not recommended for the elderly because of poor bone quality and the need for bed rest. In the acute phase, total hip arthroplasty may be the best treatment option because it allows early mobilization and avoids bed rest complications. We report the case of a 76-year-old man with a bilateral comminuted acetabular fractures and a left fracture dislocation of the shoulder, treated by immediate shoulder arthroplasty and a one-stage bilateral total hip arthroplasty procedure at 3 weeks, with a good result at 1-year follow-up.
Collapse
|
12
|
Röhner E, Matziolis G. [Use of dual mobility cups for revision hip arthroplasty]. DER ORTHOPADE 2017; 46:114-120. [PMID: 28097416 DOI: 10.1007/s00132-016-3383-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The dual mobility cup (DMC) is an increasingly important tool not only in primary but also in revision total hip arthroplasty to prevent dislocation and eventually reduce postoperative complication rates. Various studies have shown survival rates with DMCs of up to 100% with an average dislocation rate of less than 1.5% after primary hip arthroplasty and a follow-up of 10 years. In revision surgery, survival rates of up to 99% were reported with dislocation rates between 0 and 10% after an average of 5 years after implantation. This article is intended to provide an overview of the principle and function of DMCs. Furthermore, indications as well as complications are presented.
Collapse
Affiliation(s)
- E Röhner
- Orthopädische Klinik des Universitätsklinikums Jena am Campus Eisenberg, Waldkrankenhaus "Rudolf Elle" GmbH, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland.
| | - G Matziolis
- Orthopädische Klinik des Universitätsklinikums Jena am Campus Eisenberg, Waldkrankenhaus "Rudolf Elle" GmbH, Klosterlausnitzer Straße 81, 07607, Eisenberg, Deutschland
| |
Collapse
|