1
|
Belotti G, Fattori G, Baroni G, Rit S. Extension of the cone-beam CT field-of-view using two complementary short scans. Med Phys 2024; 51:3391-3404. [PMID: 38043079 DOI: 10.1002/mp.16869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 10/10/2023] [Accepted: 11/09/2023] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND Robotic C-arm cone-beam computed tomography (CBCT) scanners provide fast in-room imaging in radiotherapy. Their mobility extends beyond performing a gantry rotation, but they might encounter obstructions to their motion which limit the gantry angle range. The axial field-of-view (FOV) of a reconstructed CBCT image depends on the acquisition geometry. When imaging a large anatomical location, such as the thorax, abdomen, or pelvis, a centered cone beam might be insufficient to acquire untruncated projection images. Some CBCT scanners can laterally displace their detector and collimate the beam to increase the FOV, but the gantry must then perform a360 ∘ $360^{\circ}$ rotation to provide complete data for reconstruction. PURPOSE To extend the FOV of a CBCT image with a single short scan (gantry angle range of180 ∘ + $180^{\circ}+$ fan angle) using two complementary short scans. METHODS We defined an acquisition protocol using two short scans during which the source follows the same trajectory and where the detector has equal and opposite tilt and/or offset between the two scans, which we refer to as complementary scans. We created virtual acquisitions using a Monte Carlo simulator on a digital anthropomorphic phantom and on a computed tomography (CT) scan of a patient abdomen. For our proposed method, each simulation produced two complementary sets of projections, which were weighted for redundancies and used to reconstruct one CBCT image. We compared the resulting images to the ground truth phantoms and simulations of conventional scans. RESULTS Reconstruction artifacts were slightly more prominent in the complementary scans w.r.t. a complete scan with untruncated projections but matched those in a single short scan without truncation. When analyzing reconstructed scans from simulated projections with scatter and corrected with prior CT information, we found a global agreement between complementary and conventional scan approaches. CONCLUSIONS When dealing with a limited range of motion of the gantry of a CBCT scanner, two complementary short scans are a technically valid alternative to a full 360∘ $^{\circ}$ scan with equal FOV. This approach enables FOV extension without collisions or hardware upgrades.
Collapse
Affiliation(s)
- Gabriele Belotti
- Department of Electronics, Information and Bioengineering, CartCasLab, Politecnico di Milano (MI), Milan, Italy
| | - Giovanni Fattori
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, CartCasLab, Politecnico di Milano (MI), Milan, Italy
- Centro Nazionale di Adroterapia Oncologica (CNAO), Pavia (PV), Italy
| | - Simon Rit
- Univ Lyon, CREATIS, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR5220, U1294, Lyon, France
| |
Collapse
|
2
|
Wang T, Liu X, Dai J, Zhang C, He W, Liu L, Chan Y, He Y, Zhao H, Xie Y, Liang X. An unsupervised dual contrastive learning framework for scatter correction in cone-beam CT image. Comput Biol Med 2023; 165:107377. [PMID: 37651766 DOI: 10.1016/j.compbiomed.2023.107377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 08/08/2023] [Accepted: 08/14/2023] [Indexed: 09/02/2023]
Abstract
PURPOSE Cone-beam computed tomography (CBCT) is widely utilized in modern radiotherapy; however, CBCT images exhibit increased scatter artifacts compared to planning CT (pCT), compromising image quality and limiting further applications. Scatter correction is thus crucial for improving CBCT image quality. METHODS In this study, we proposed an unsupervised contrastive learning method for CBCT scatter correction. Initially, we transformed low-quality CBCT into high-quality synthetic pCT (spCT) and generated forward projections of CBCT and spCT. By computing the difference between these projections, we obtained a residual image containing image details and scatter artifacts. Image details primarily comprise high-frequency signals, while scatter artifacts consist mainly of low-frequency signals. We extracted the scatter projection signal by applying a low-pass filter to remove image details. The corrected CBCT (cCBCT) projection signal was obtained by subtracting the scatter artifacts projection signal from the original CBCT projection. Finally, we employed the FDK reconstruction algorithm to generate the cCBCT image. RESULTS To evaluate cCBCT image quality, we aligned the CBCT and pCT of six patients. In comparison to CBCT, cCBCT maintains anatomical consistency and significantly enhances CT number, spatial homogeneity, and artifact suppression. The mean absolute error (MAE) of the test data decreased from 88.0623 ± 26.6700 HU to 17.5086 ± 3.1785 HU. The MAE of fat regions of interest (ROIs) declined from 370.2980 ± 64.9730 HU to 8.5149 ± 1.8265 HU, and the error between their maximum and minimum CT numbers decreased from 572.7528 HU to 132.4648 HU. The MAE of muscle ROIs reduced from 354.7689 ± 25.0139 HU to 16.4475 ± 3.6812 HU. We also compared our proposed method with several conventional unsupervised synthetic image generation techniques, demonstrating superior performance. CONCLUSIONS Our approach effectively enhances CBCT image quality and shows promising potential for future clinical adoption.
Collapse
Affiliation(s)
- Tangsheng Wang
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China; University of Chinese Academy of Sciences, Beijing 101408, China.
| | - Xuan Liu
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Jingjing Dai
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Chulong Zhang
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Wenfeng He
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Lin Liu
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China; University of Chinese Academy of Sciences, Beijing 101408, China.
| | - Yinping Chan
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Yutong He
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Hanqing Zhao
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China; University of Chinese Academy of Sciences, Beijing 101408, China.
| | - Yaoqin Xie
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| | - Xiaokun Liang
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China.
| |
Collapse
|
3
|
Aouadi S, Yoganathan SA, Torfeh T, Paloor S, Caparrotti P, Hammoud R, Al-Hammadi N. Generation of synthetic CT from CBCT using deep learning approaches for head and neck cancer patients. Biomed Phys Eng Express 2023; 9:055020. [PMID: 37489854 DOI: 10.1088/2057-1976/acea27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Accepted: 07/25/2023] [Indexed: 07/26/2023]
Abstract
Purpose.To create a synthetic CT (sCT) from daily CBCT using either deep residual U-Net (DRUnet), or conditional generative adversarial network (cGAN) for adaptive radiotherapy planning (ART).Methods.First fraction CBCT and planning CT (pCT) were collected from 93 Head and Neck patients who underwent external beam radiotherapy. The dataset was divided into training, validation, and test sets of 58, 10 and 25 patients respectively. Three methods were used to generate sCT, 1. Nonlocal means patch based method was modified to include multiscale patches defining the multiscale patch based method (MPBM), 2. An encoder decoder 2D Unet with imbricated deep residual units was implemented, 3. DRUnet was integrated to the generator part of cGAN whereas a convolutional PatchGAN classifier was used as the discriminator. The accuracy of sCT was evaluated geometrically using Mean Absolute Error (MAE). Clinical Volumetric Modulated Arc Therapy (VMAT) plans were copied from pCT to registered CBCT and sCT and dosimetric analysis was performed by comparing Dose Volume Histogram (DVH) parameters of planning target volumes (PTVs) and organs at risk (OARs). Furthermore, 3D Gamma analysis (2%/2mm, global) between the dose on the sCT or CBCT and that on the pCT was performed.Results. The average MAE calculated between pCT and CBCT was 180.82 ± 27.37HU. Overall, all approaches significantly reduced the uncertainties in CBCT. Deep learning approaches outperformed patch-based methods with MAE = 67.88 ± 8.39HU (DRUnet) and MAE = 72.52 ± 8.43HU (cGAN) compared to MAE = 90.69 ± 14.3HU (MPBM). The percentages of DVH metric deviations were below 0.55% for PTVs and 1.17% for OARs using DRUnet. The average Gamma pass rate was 99.45 ± 1.86% for sCT generated using DRUnet.Conclusion.DL approaches outperformed MPBM. Specifically, DRUnet could be used for the generation of sCT with accurate intensities and realistic description of patient anatomy. This could be beneficial for CBCT based ART.
Collapse
Affiliation(s)
- Souha Aouadi
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| | - S A Yoganathan
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| | - Tarraf Torfeh
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| | - Satheesh Paloor
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| | - Palmira Caparrotti
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| | - Rabih Hammoud
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| | - Noora Al-Hammadi
- Department of Radiation Oncology, National Center for Cancer Care and Research, Hamad Medical Corporation, PO Box 3050 Doha, Qatar
| |
Collapse
|
4
|
Schmitz H, Rabe M, Janssens G, Rit S, Parodi K, Belka C, Kamp F, Landry G, Kurz C. Scatter correction of 4D cone beam computed tomography to detect dosimetric effects due to anatomical changes in proton therapy for lung cancer. Med Phys 2023; 50:4981-4992. [PMID: 36847184 DOI: 10.1002/mp.16335] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 02/01/2023] [Accepted: 02/14/2023] [Indexed: 03/01/2023] Open
Abstract
BACKGROUND The treatment of moving tumor entities is expected to have superior clinical outcomes, using image-guided adaptive intensity-modulated proton therapy (IMPT). PURPOSE For 21 lung cancer patients, IMPT dose calculations were performed on scatter-corrected 4D cone beam CTs (4DCBCTcor ) to evaluate their potential for triggering treatment adaptation. Additional dose calculations were performed on corresponding planning 4DCTs and day-of-treatment 4D virtual CTs (4DvCTs). METHODS A 4DCBCT correction workflow, previously validated on a phantom, generates 4DvCT (CT-to-CBCT deformable registration) and 4DCBCTcor images (projection-based correction using 4DvCT as a prior) with 10 phase bins, using day-of-treatment free-breathing CBCT projections and planning 4DCT images as input. Using a research planning system, robust IMPT plans administering eight fractions of 7.5 Gy were created on a free-breathing planning CT (pCT) contoured by a physician. The internal target volume (ITV) was overridden with muscle tissue. Robustness settings for range and setup uncertainties were 3% and 6 mm, and a Monte Carlo dose engine was used. On every phase of planning 4DCT, day-of-treatment 4DvCT, and 4DCBCTcor , the dose was recalculated. For evaluation, image analysis as well as dose analysis were performed using mean error (ME) and mean absolute error (MAE) analysis, dose-volume histogram (DVH) parameters, and 2%/2-mm gamma pass rate analysis. Action levels (1.6% ITV D98 and 90% gamma pass rate) based on our previous phantom validation study were set to determine which patients had a loss of dosimetric coverage. RESULTS Quality enhancements of 4DvCT and 4DCBCTcor over 4DCBCT were observed. ITV D98% and bronchi D2% had its largest agreement for 4DCBCTcor -4DvCT, and the largest gamma pass rates (>94%, median 98%) were found for 4DCBCTcor -4DvCT. Deviations were larger and gamma pass rates were smaller for 4DvCT-4DCT and 4DCBCTcor -4DCT. For five patients, deviations were larger than the action levels, suggesting substantial anatomical changes between pCT and CBCT projections acquisition. CONCLUSIONS This retrospective study shows the feasibility of daily proton dose calculation on 4DCBCTcor for lung tumor patients. The applied method is of clinical interest as it generates up-to-date in-room images, accounting for breathing motion and anatomical changes. This information could be used to trigger replanning.
Collapse
Affiliation(s)
- Henning Schmitz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Bavaria, Germany
| | - Moritz Rabe
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Bavaria, Germany
| | | | - Simon Rit
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69373, Lyon, France
| | - Katia Parodi
- Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching (Munich), Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Bavaria, Germany
- German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Bavaria, Germany
- Department of Radiation Oncology, University Hospital Cologne, Cologne, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Bavaria, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Bavaria, Germany
| |
Collapse
|
5
|
Schmitz H, Thummerer A, Kawula M, Lombardo E, Parodi K, Belka C, Kamp F, Kurz C, Landry G. ScatterNet for projection-based 4D cone-beam computed tomography intensity correction of lung cancer patients. Phys Imaging Radiat Oncol 2023; 27:100482. [PMID: 37680905 PMCID: PMC10480315 DOI: 10.1016/j.phro.2023.100482] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 08/04/2023] [Accepted: 08/11/2023] [Indexed: 09/09/2023] Open
Abstract
Background and purpose: In radiotherapy, dose calculations based on 4D cone beam CTs (4DCBCTs) require image intensity corrections. This retrospective study compared the dose calculation accuracy of a deep learning, projection-based scatter correction workflow (ScatterNet), to slower workflows: conventional 4D projection-based scatter correction (CBCTcor) and a deformable image registration (DIR)-based method (4DvCT). Materials and methods: For 26 lung cancer patients, planning CTs (pCTs), 4DCTs and CBCT projections were available. ScatterNet was trained with pairs of raw and corrected CBCT projections. Corrected projections from ScatterNet and the conventional workflow were reconstructed using MA-ROOSTER, yielding 4DCBCTSN and 4DCBCTcor. The 4DvCT was generated by 4DCT to 4DCBCT DIR, as part of the 4DCBCTcor workflow. Robust intensity modulated proton therapy treatment plans were created on free-breathing pCTs. 4DCBCTSN was compared to 4DCBCTcor and the 4DvCT in terms of image quality and dose calculation accuracy (dose-volume-histogram parameters and 3 % /3 mm gamma analysis). Results: 4DCBCTSN resulted in an average mean absolute error of 87 HU and 102 HU when compared to 4DCBCTcor and 4DvCT respectively. High agreement was observed in targets with median dose differences of 0.4 Gy (4DCBCTSN-4DCBCTcor) and 0.3 Gy (4DCBCTSN-4DvCT). The gamma analysis showed high average 3 % /3 mm pass rates of 96 % for both 4DCBCTSN vs. 4DCBCTcor and 4DCBCTSN vs. 4DvCT. Conclusions: Accurate 4D dose calculations are feasible for lung cancer patients using ScatterNet for 4DCBCT correction. Average scatter correction times could be reduced from 10 min (4DCBCTcor) to 3.9 s , showing the clinical suitability of the proposed deep learning-based method.
Collapse
Affiliation(s)
- Henning Schmitz
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Adrian Thummerer
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Maria Kawula
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Elia Lombardo
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Katia Parodi
- Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching (Munich), Germany
| | - Claus Belka
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
- German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany
- Bavarian Cancer Research Center (BZKF), Munich, Germany
| | - Florian Kamp
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
- Department of Radiation Oncology, University Hospital Cologne, Cologne, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
6
|
Kang SR, Shin W, Yang S, Kim JE, Huh KH, Lee SS, Heo MS, Yi WJ. Structure-preserving quality improvement of cone beam CT images using contrastive learning. Comput Biol Med 2023; 158:106803. [PMID: 36989743 DOI: 10.1016/j.compbiomed.2023.106803] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/13/2023] [Accepted: 03/20/2023] [Indexed: 03/29/2023]
Abstract
Cone-beam CT (CBCT) is widely used in dental clinics but exhibits limitations in assessing soft tissue pathology because of its lack of contrast resolution and low Hounsfield Units (HU) quantification accuracy. We aimed to increase the image quality and HU accuracy of CBCTs while preserving anatomical structures. We generated CT-like images from CBCT images using a patchwise contrastive learning-based GAN model. Our model was trained on unpaired CT and CBCT datasets with the novel combination of losses and the feature extractor pretrained on our training dataset. We evaluated the quality of the images generated by our model in terms of Fréchet inception distance (FID), peak signal-to-noise ratio (PSNR), mean absolute error (MAE), and root mean square error (RMSE). Additionally, the structure preservation performance was assessed by the structure score. As a result, the generated CT-like images by our model were significantly superior to those generated by various baseline models in terms of FID, PSNR, MAE, RMSE, and structure score. Therefore, we demonstrated that our model provided the complementary benefits of preserving the anatomical structures of the input CBCT images and improving the image quality to be similar to those of CT images.
Collapse
|
7
|
Jihong C, Kerun Q, Kaiqiang C, Xiuchun Z, Yimin Z, Penggang B. CBCT-based synthetic CT generated using CycleGAN with HU correction for adaptive radiotherapy of nasopharyngeal carcinoma. Sci Rep 2023; 13:6624. [PMID: 37095147 PMCID: PMC10125979 DOI: 10.1038/s41598-023-33472-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 04/13/2023] [Indexed: 04/26/2023] Open
Abstract
This study aims to utilize a hybrid approach of phantom correction and deep learning for synthesized CT (sCT) images generation based on cone-beam CT (CBCT) images for nasopharyngeal carcinoma (NPC). 52 CBCT/CT paired images of NPC patients were used for model training (41), validation (11). Hounsfield Units (HU) of the CBCT images was calibrated by a commercially available CIRS phantom. Then the original CBCT and the corrected CBCT (CBCT_cor) were trained separately with the same cycle generative adversarial network (CycleGAN) to generate SCT1 and SCT2. The mean error and mean absolute error (MAE) were used to quantify the image quality. For validations, the contours and treatment plans in CT images were transferred to original CBCT, CBCT_cor, SCT1 and SCT2 for dosimetric comparison. Dose distribution, dosimetric parameters and 3D gamma passing rate were analyzed. Compared with rigidly registered CT (RCT), the MAE of CBCT, CBCT_cor, SCT1 and SCT2 were 346.11 ± 13.58 HU, 145.95 ± 17.64 HU, 105.62 ± 16.08 HU and 83.51 ± 7.71 HU, respectively. Moreover, the average dosimetric parameter differences for the CBCT_cor, SCT1 and SCT2 were 2.7% ± 1.4%, 1.2% ± 1.0% and 0.6% ± 0.6%, respectively. Using the dose distribution of RCT images as reference, the 3D gamma passing rate of the hybrid method was significantly better than the other methods. The effectiveness of CBCT-based sCT generated using CycleGAN with HU correction for adaptive radiotherapy of nasopharyngeal carcinoma was confirmed. The image quality and dose accuracy of SCT2 were outperform the simple CycleGAN method. This finding has great significance for the clinical application of adaptive radiotherapy for NPC.
Collapse
Affiliation(s)
- Chen Jihong
- Department of Radiation Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, 350014, Fujian, China
| | - Quan Kerun
- Department of Radiation Oncology, Xiangtan City Central Hospital, Xiangtan, 411100, Hunan, China
| | - Chen Kaiqiang
- Department of Radiation Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, 350014, Fujian, China
| | - Zhang Xiuchun
- Department of Radiation Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, 350014, Fujian, China
| | - Zhou Yimin
- School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China
| | - Bai Penggang
- Department of Radiation Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, 350014, Fujian, China.
| |
Collapse
|
8
|
Gong H, Liu B, Zhang G, Dai X, Qu B, Cai B, Xie C, Xu S. Evaluation of Dose Calculation Based on Cone-Beam CT Using Different Measuring Correction Methods for Head and Neck Cancer Patients. Technol Cancer Res Treat 2023; 22:15330338221148317. [PMID: 36638542 PMCID: PMC9841465 DOI: 10.1177/15330338221148317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
Purpose: To investigate and compare 2 cone-beam computed tomography (CBCT) correction methods for CBCT-based dose calculation. Materials and Methods: Routine CBCT image sets of 12 head and neck cancer patients who received volumetric modulated arc therapy (VMAT) treatment were retrospectively analyzed. The CBCT images obtained using an on-board imager (OBI) at the first treatment fraction were firstly deformable registered and padded with the kVCT images to provide enough anatomical information about the tissues for dose calculation. Then, 2 CBCT correction methods were developed and applied to correct CBCT Hounsfield unit (HU) values. One method (HD method) is based on protocol-specific CBCT HU to physical density (HD) curve, and the other method (HM method) is based on histogram matching (HM) of HU value. The corrected CBCT images (CBCTHD and CBCTHM for HD and HM methods) were imported into the original planning system for dose calculation based on the HD curve of kVCT (the planning CT). The dose computation result was analyzed and discussed to compare these 2 CBCT-correction methods. Results: Dosimetric parameters, such as the Dmean, Dmax and D5% of the target volume in CBCT plan doses, were higher than those in the kVCT plan doses; however, the deviations were less than 2%. The D2%, in parallel organs such as the parotid glands, the deviations from the CBCTHM plan dose were less than those of the CBCTHD plan dose. The differences were statistically significant (P < .05). Meanwhile, the V30 value based on the HM method was better than that based on the HD method in the oral cavity region (P = .016). In addition, we also compared the γ passing rates of kVCT plan doses with the 2 CBCT plan doses, and negligible differences were found. Conclusion: The HM method was more suitable for head and neck cancer patients than the HD one. Furthermore, with the CBCTHM-based method, the dose calculation result better matches the kVCT-based dose calculation.
Collapse
Affiliation(s)
- Hanshun Gong
- Department of Radiation Oncology, The First Medical Center of PLA General
Hospital, Beijing, China
| | - Bo Liu
- School of Astronautics, Beihang
University, Beijing, China
| | - Gaolong Zhang
- School of Physics, Beihang
University, Beijing, China
| | - Xiangkun Dai
- Department of Radiation Oncology, The First Medical Center of PLA General
Hospital, Beijing, China
| | - Baolin Qu
- Department of Radiation Oncology, The First Medical Center of PLA General
Hospital, Beijing, China
| | - Boning Cai
- Department of Radiation Oncology, The First Medical Center of PLA General
Hospital, Beijing, China
| | - Chuanbin Xie
- Department of Radiation Oncology, The First Medical Center of PLA General
Hospital, Beijing, China
| | - Shouping Xu
- Department of Radiation Oncology, National Cancer Center/Cancer
Hospital, Chinese
Academy of Medical Sciences and Peking Union Medical
College, Beijing, China,National Cancer Center/National Clinical Research Center for
Cancer/Hebei Cancer Hospital, Chinese Academy of Medical
Sciences, Langfang, China,Shouping Xu, Department of Radiation
Oncology, National Cancer Center/Cancer Hospital, Chinese Academy of Medical
Sciences and Peking Union Medical College, Beijing, China.
| |
Collapse
|
9
|
Sarrut D, Arbor N, Baudier T, Borys D, Etxebeste A, Fuchs H, Gajewski J, Grevillot L, Jan S, Kagadis GC, Kang HG, Kirov A, Kochebina O, Krzemien W, Lomax A, Papadimitroulas P, Pommranz C, Roncali E, Rucinski A, Winterhalter C, Maigne L. The OpenGATE ecosystem for Monte Carlo simulation in medical physics. Phys Med Biol 2022; 67:10.1088/1361-6560/ac8c83. [PMID: 36001985 PMCID: PMC11149651 DOI: 10.1088/1361-6560/ac8c83] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 08/24/2022] [Indexed: 11/12/2022]
Abstract
This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. Based on the shoulders of Geant4, the principal modules (geometry, physics, scorers) are described with brief descriptions of some key concepts (Volume, Actors, Digitizer). The main source code repositories are detailed together with the automated compilation and tests processes (Continuous Integration). We then described how the OpenGATE collaboration managed the collaborative development of about one hundred developers during almost 20 years. The impact of GATE on medical physics and cancer research is then summarized, and examples of a few key applications are given. Finally, future development perspectives are indicated.
Collapse
Affiliation(s)
- David Sarrut
- Université de Lyon; CREATIS; CNRS UMR5220; Inserm U1294; INSA-Lyon; Université Lyon 1, Léon Bérard cancer center, Lyon, France
| | - Nicolas Arbor
- Université de Strasbourg, IPHC, CNRS, UMR7178, F-67037 Strasbourg, France
| | - Thomas Baudier
- Université de Lyon; CREATIS; CNRS UMR5220; Inserm U1294; INSA-Lyon; Université Lyon 1, Léon Bérard cancer center, Lyon, France
| | - Damian Borys
- Department of Systems Biology and Engineering, Silesian University of Technology, Gliwice, Poland
| | - Ane Etxebeste
- Université de Lyon; CREATIS; CNRS UMR5220; Inserm U1294; INSA-Lyon; Université Lyon 1, Léon Bérard cancer center, Lyon, France
| | - Hermann Fuchs
- MedAustron Ion Therapy Center, Wiener Neustadt, Austria
- Medical University of Vienna, Department of Radiation Oncology, Vienna, Vienna, Währinger Gürtel 18-20, A-1090 Wien, Austria
| | - Jan Gajewski
- Institute of Nuclear Physics Polish Academy of Sciences, Krakow, Poland
| | | | - Sébastien Jan
- Université Paris-Saclay, Inserm, CNRS, CEA, Laboratoire d'Imagerie Biomédicale Multimodale (BioMaps), F-91401 Orsay, France
| | - George C Kagadis
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece
| | - Han Gyu Kang
- National Institutes for Quantum Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| | - Assen Kirov
- Memorial Sloan Kettering Cancer, New York, NY 10021, United States of America
| | - Olga Kochebina
- Université Paris-Saclay, Inserm, CNRS, CEA, Laboratoire d'Imagerie Biomédicale Multimodale (BioMaps), F-91401 Orsay, France
| | - Wojciech Krzemien
- High Energy Physics Division, National Centre for Nuclear Research, Otwock-Świerk, Poland
- Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, S. Lojasiewicza 11, 30-348 Krakow, Poland
- Centre for Theranostics, Jagiellonian University, Kopernika 40 St, 31 501 Krakow, Poland
| | - Antony Lomax
- Center for Proton Therapy, PSI, Switzerland
- Department of Physics, ETH Zurich, Switzerland
| | | | - Christian Pommranz
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Roentgenweg 13, D-72076 Tuebingen, Germany
- Institute for Astronomy and Astrophysics, Eberhard Karls University Tuebingen, Sand 1, D-72076 Tuebingen, Germany
| | - Emilie Roncali
- University of California Davis, Departments of Biomedical Engineering and Radiology, Davis, CA 95616, United States of America
| | - Antoni Rucinski
- Institute of Nuclear Physics Polish Academy of Sciences, Krakow, Poland
| | - Carla Winterhalter
- Center for Proton Therapy, PSI, Switzerland
- Department of Physics, ETH Zurich, Switzerland
| | - Lydia Maigne
- Université Clermont Auvergne, Laboratoire de Physique de Clermont, CNRS, UMR 6533, F-63178 Aubière, France
| |
Collapse
|
10
|
Wang X, Jian W, Zhang B, Zhu L, He Q, Jin H, Yang G, Cai C, Meng H, Tan X, Li F, Dai Z. Synthetic CT generation from cone-beam CT using deep-learning for breast adaptive radiotherapy. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2022. [DOI: 10.1016/j.jrras.2022.03.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
11
|
Yuan N, Rao S, Chen Q, Sensoy L, Qi J, Rong Y. Head and neck synthetic CT generated from ultra-low-dose cone-beam CT following Image Gently Protocol using deep neural network. Med Phys 2022; 49:3263-3277. [PMID: 35229904 DOI: 10.1002/mp.15585] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 02/08/2022] [Accepted: 02/21/2022] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Image guidance is used to improve accuracy of radiation therapy delivery but results in increased dose to patients. This is of particular concern in children who need be treated per Pediatric Image Gently Protocols due to long term risks from radiation exposure. The purpose of this study is to design a deep neural network (DNN) architecture and loss function for improving soft-tissue contrast and preserving small anatomical features in ultra-low-dose cone-beam CTs (CBCT) of head and neck cancer (HNC) imaging. METHODS A 2-D compound U-Net architecture (modified U-Net++) with different depths was proposed to enhance the network capability of capturing small-volume structures. A mask weighted loss function (Mask-Loss) was applied to enhance soft-tissue contrast. Fifty-five paired CBCT and CT images of HNC patients were retrospectively collected for network training and testing. The output enhanced CBCT images from the present study were evaluated with quantitative metrics including mean absolute error (MAE), signal-to-noise ratio (SNR), and structural similarity (SSIM), and compared with those from the previously proposed network architectures (U-Net and wide U-Net) using MAE loss functions. A visual assessment of ten selected structures in the enhanced CBCT images of each patient was performed to evaluate image quality improvement, blindly scored by an experienced radiation oncologist specialized in HN cancer. RESULTS All the enhanced CBCT images showed reduced artifactual distortion and image noise. U-Net++ outperformed the U-Net and wide U-Net in terms of MAE, contrast near structure boundaries, and small structures. The proposed Mask-Loss improved image contrast and accuracy of the soft-tissue regions. The enhanced CBCT images predicted by U-Net++ and Mask-Loss demonstrated improvement compared to the U-Net in terms of average MAE (52.41 vs. 42.85 HU), SNR (14.14 vs. 15.07 dB), and SSIM (0.84 vs. 0.87), respectively (p < 0.01, in all paired t-tests). The visual assessment showed that the proposed U-Net++ and Mask-Loss significantly improved original CBCTs (p < 0.01), compared to the U-Net and MAE loss. CONCLUSIONS The proposed network architecture and loss function effectively improved image quality in soft-tissue contrast, organ boundary, and small structures preservation for ultra-low-dose CBCT following Image Gently Protocol. This method has potential to provide sufficient anatomical representation on the enhanced CBCT images for accurate treatment delivery and potentially fast online-adaptive re-planning for HN cancer patients. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Nimu Yuan
- Department of Biomedical Engineering, University of California, Davis, CA, 95616, United States
| | - Shyam Rao
- Department of Radiation Oncology, University of California Davis Medical Center, Sacramento, CA, 95817, United States
| | - Quan Chen
- Department of Radiation Oncology, University of Kentucky, Lexington, KY, 40536, United States
| | - Levent Sensoy
- Department of Radiation Oncology, University of California Davis Medical Center, Sacramento, CA, 95817, United States
| | - Jinyi Qi
- Department of Biomedical Engineering, University of California, Davis, CA, 95616, United States
| | - Yi Rong
- Department of Radiation Oncology, University of California Davis Medical Center, Sacramento, CA, 95817, United States.,Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, 85054, United States
| |
Collapse
|
12
|
Hase T, Nakao M, Imanishi K, Nakamura M, Matsuda T. Improvement of Image Quality of Cone-beam CT Images by Three-dimensional Generative Adversarial Network. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:2843-2846. [PMID: 34891840 DOI: 10.1109/embc46164.2021.9629952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Artifacts and defects in Cone-beam Computed Tomography (CBCT) images are a problem in radiotherapy and surgical procedures. Unsupervised learning-based image translation techniques have been studied to improve the image quality of head and neck CBCT images, but there have been few studies on improving the image quality of abdominal CBCT images, which are strongly affected by organ deformation due to posture and breathing. In this study, we propose a method for improving the image quality of abdominal CBCT images by translating the numerical values to the values of corresponding paired CT images using an unsupervised CycleGAN framework. This method preserves anatomical structure through adversarial learning that translates voxel values according to corresponding regions between CBCT and CT images of the same case. The image translation model was trained on 68 CT-CBCT datasets and then applied to 8 test datasets, and the effectiveness of the proposed method for improving the image quality of CBCT images was confirmed.
Collapse
|
13
|
Rossi M, Belotti G, Paganelli C, Pella A, Barcellini A, Cerveri P, Baroni G. Image-based shading correction for narrow-FOV truncated pelvic CBCT with deep convolutional neural networks and transfer learning. Med Phys 2021; 48:7112-7126. [PMID: 34636429 PMCID: PMC9297981 DOI: 10.1002/mp.15282] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 09/29/2021] [Accepted: 10/01/2021] [Indexed: 11/21/2022] Open
Abstract
Purpose: Cone beam computed tomography (CBCT) is a standard solution for in‐room image guidance for radiation therapy. It is used to evaluate and compensate for anatomopathological changes between the dose delivery plan and the fraction delivery day. CBCT is a fast and versatile solution, but it suffers from drawbacks like low contrast and requires proper calibration to derive density values. Although these limitations are even more prominent with in‐room customized CBCT systems, strategies based on deep learning have shown potential in improving image quality. As such, this article presents a method based on a convolutional neural network and a novel two‐step supervised training based on the transfer learning paradigm for shading correction in CBCT volumes with narrow field of view (FOV) acquired with an ad hoc in‐room system. Methods: We designed a U‐Net convolutional neural network, trained on axial slices of corresponding CT/CBCT couples. To improve the generalization capability of the network, we exploited two‐stage learning using two distinct data sets. At first, the network weights were trained using synthetic CBCT scans generated from a public data set, and then only the deepest layers of the network were trained again with real‐world clinical data to fine‐tune the weights. Synthetic data were generated according to real data acquisition parameters. The network takes a single grayscale volume as input and outputs the same volume with corrected shading and improved HU values. Results: Evaluation was carried out with a leave‐one‐out cross‐validation, computed on 18 unique CT/CBCT pairs from six different patients from a real‐world dataset. Comparing original CBCT to CT and improved CBCT to CT, we obtained an average improvement of 6 dB on peak signal‐to‐noise ratio (PSNR), +2% on structural similarity index measure (SSIM). The median interquartile range (IQR) Hounsfield unit (HU) difference between CBCT and CT improved from 161.37 (162.54) HU to 49.41 (66.70) HU. Region of interest (ROI)‐based HU difference was narrowed by 75% in the spongy bone (femoral head), 89% in the bladder, 85% for fat, and 83% for muscle. The improvement in contrast‐to‐noise ratio for these ROIs was about 67%. Conclusions: We demonstrated that shading correction obtaining CT‐compatible data from narrow‐FOV CBCTs acquired with a customized in‐room system is possible. Moreover, the transfer learning approach proved particularly beneficial for such a shading correction approach.
Collapse
Affiliation(s)
- Matteo Rossi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Gabriele Belotti
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Andrea Pella
- Bioengineering Unit, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Amelia Barcellini
- Radiation Oncology Unit, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| | - Pietro Cerveri
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.,Bioengineering Unit, Clinical Department, National Center for Oncological Hadrontherapy (CNAO), Pavia, Italy
| |
Collapse
|
14
|
Schmitz H, Rabe M, Janssens G, Bondesson D, Rit S, Parodi K, Belka C, Dinkel J, Kurz C, Kamp F, Landry G. Validation of proton dose calculation on scatter corrected 4D cone beam computed tomography using a porcine lung phantom. Phys Med Biol 2021; 66. [PMID: 34293737 DOI: 10.1088/1361-6560/ac16e9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 07/22/2021] [Indexed: 12/25/2022]
Abstract
Proton therapy treatment for lungs remains challenging as images enabling the detection of inter- and intra-fractional motion, which could be used for proton dose adaptation, are not readily available. 4D computed tomography (4DCT) provides high image quality but is rarely available in-room, while in-room 4D cone beam computed tomography (4DCBCT) suffers from image quality limitations stemming mostly from scatter detection. This study investigated the feasibility of using virtual 4D computed tomography (4DvCT) as a prior for a phase-per-phase scatter correction algorithm yielding a 4D scatter corrected cone beam computed tomography image (4DCBCTcor), which can be used for proton dose calculation. 4DCT and 4DCBCT scans of a porcine lung phantom, which generated reproducible ventilation, were acquired with matching breathing patterns. Diffeomorphic Morphons, a deformable image registration algorithm, was used to register the mid-position 4DCT to the mid-position 4DCBCT and yield a 4DvCT. The 4DCBCT was reconstructed using motion-aware reconstruction based on spatial and temporal regularization (MA-ROOSTER). Successively for each phase, digitally reconstructed radiographs of the 4DvCT, simulated without scatter, were exploited to correct scatter in the corresponding CBCT projections. The 4DCBCTcorwas then reconstructed with MA-ROOSTER using the corrected CBCT projections and the same settings and deformation vector fields as those already used for reconstructing the 4DCBCT. The 4DCBCTcorand the 4DvCT were evaluated phase-by-phase, performing proton dose calculations and comparison to those of a ground truth 4DCT by means of dose-volume-histograms (DVH) and gamma pass-rates (PR). For accumulated doses, DVH parameters deviated by at most 1.7% in the 4DvCT and 2.0% in the 4DCBCTcorcase. The gamma PR for a (2%, 2 mm) criterion with 10% threshold were at least 93.2% (4DvCT) and 94.2% (4DCBCTcor), respectively. The 4DCBCTcortechnique enabled accurate proton dose calculation, which indicates the potential for applicability to clinical 4DCBCT scans.
Collapse
Affiliation(s)
- Henning Schmitz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Moritz Rabe
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | | | - David Bondesson
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Simon Rit
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373, LYON, France
| | - Katia Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching (Munich), Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany
| | - Julien Dinkel
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching (Munich), Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,Department of Radiation Oncology, University Hospital Cologne, Cologne, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching (Munich), Germany
| |
Collapse
|
15
|
Rossi M, Cerveri P. Comparison of Supervised and Unsupervised Approaches for the Generation of Synthetic CT from Cone-Beam CT. Diagnostics (Basel) 2021; 11:diagnostics11081435. [PMID: 34441369 PMCID: PMC8395013 DOI: 10.3390/diagnostics11081435] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/30/2021] [Accepted: 08/07/2021] [Indexed: 12/04/2022] Open
Abstract
Due to major artifacts and uncalibrated Hounsfield units (HU), cone-beam computed tomography (CBCT) cannot be used readily for diagnostics and therapy planning purposes. This study addresses image-to-image translation by convolutional neural networks (CNNs) to convert CBCT to CT-like scans, comparing supervised to unsupervised training techniques, exploiting a pelvic CT/CBCT publicly available dataset. Interestingly, quantitative results were in favor of supervised against unsupervised approach showing improvements in the HU accuracy (62% vs. 50%), structural similarity index (2.5% vs. 1.1%) and peak signal-to-noise ratio (15% vs. 8%). Qualitative results conversely showcased higher anatomical artifacts in the synthetic CBCT generated by the supervised techniques. This was motivated by the higher sensitivity of the supervised training technique to the pixel-wise correspondence contained in the loss function. The unsupervised technique does not require correspondence and mitigates this drawback as it combines adversarial, cycle consistency, and identity loss functions. Overall, two main impacts qualify the paper: (a) the feasibility of CNN to generate accurate synthetic CT from CBCT images, which is fast and easy to use compared to traditional techniques applied in clinics; (b) the proposal of guidelines to drive the selection of the better training technique, which can be shifted to more general image-to-image translation.
Collapse
|
16
|
Dong G, Zhang C, Liang X, Deng L, Zhu Y, Zhu X, Zhou X, Song L, Zhao X, Xie Y. A Deep Unsupervised Learning Model for Artifact Correction of Pelvis Cone-Beam CT. Front Oncol 2021; 11:686875. [PMID: 34350115 PMCID: PMC8327750 DOI: 10.3389/fonc.2021.686875] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 06/25/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose In recent years, cone-beam computed tomography (CBCT) is increasingly used in adaptive radiation therapy (ART). However, compared with planning computed tomography (PCT), CBCT image has much more noise and imaging artifacts. Therefore, it is necessary to improve the image quality and HU accuracy of CBCT. In this study, we developed an unsupervised deep learning network (CycleGAN) model to calibrate CBCT images for the pelvis to extend potential clinical applications in CBCT-guided ART. Methods To train CycleGAN to generate synthetic PCT (sPCT), we used CBCT and PCT images as inputs from 49 patients with unpaired data. Additional deformed PCT (dPCT) images attained as CBCT after deformable registration are utilized as the ground truth before evaluation. The trained uncorrected CBCT images are converted into sPCT images, and the obtained sPCT images have the characteristics of PCT images while keeping the anatomical structure of CBCT images unchanged. To demonstrate the effectiveness of the proposed CycleGAN, we use additional nine independent patients for testing. Results We compared the sPCT with dPCT images as the ground truth. The average mean absolute error (MAE) of the whole image on testing data decreased from 49.96 ± 7.21HU to 14.6 ± 2.39HU, the average MAE of fat and muscle ROIs decreased from 60.23 ± 7.3HU to 16.94 ± 7.5HU, and from 53.16 ± 9.1HU to 13.03 ± 2.63HU respectively. Conclusion We developed an unsupervised learning method to generate high-quality corrected CBCT images (sPCT). Through further evaluation and clinical implementation, it can replace CBCT in ART.
Collapse
Affiliation(s)
- Guoya Dong
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, China.,Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, China
| | - Chenglong Zhang
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin, China.,Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, China.,Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xiaokun Liang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Lei Deng
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yulin Zhu
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xuanyu Zhu
- School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, QLD, Australia
| | - Xuanru Zhou
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Liming Song
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xiang Zhao
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin, China
| | - Yaoqin Xie
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
17
|
Neppl S, Kurz C, Köpl D, Yohannes I, Schneider M, Bondesson D, Rabe M, Belka C, Dietrich O, Landry G, Parodi K, Kamp F. Measurement-based range evaluation for quality assurance of CBCT-based dose calculations in adaptive proton therapy. Med Phys 2021; 48:4148-4159. [PMID: 34032301 DOI: 10.1002/mp.14995] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 04/08/2021] [Accepted: 05/10/2021] [Indexed: 12/30/2022] Open
Abstract
PURPOSE The implementation of volumetric in-room imaging for online adaptive radiotherapy makes extensive testing of this image data for treatment planning necessary. Especially for proton beams the higher sensitivity to stopping power properties of the tissue results in more stringent requirements. Current approaches mainly focus on recalculation of the plans on the new image data, lacking experimental verification, and ignoring the impact on the plan re-optimization process. The aim of this study was to use gel and film dosimetry coupled with a three-dimensional (3D) printed head phantom (based on the planning CT of the patient) for 3D range verification of intensity-corrected cone beam computed tomography (CBCT) image data for adaptive proton therapy. METHODS Single field uniform dose pencil beam scanning proton plans were optimized for three different patients on the patients' planning CT (planCT) and the patients' intensity-corrected CBCT (scCBCT) for the same target volume using the same optimization constraints. The CBCTs were corrected on projection level using the planCT as a prior. The dose optimized on planCT and recalculated on scCBCT was compared in terms of proton range differences (80% distal fall-off, recalculation). Moreover, the dose distribution resulting from recalculation of the scCBCT-optimized plan on the planCT and the original planCT dose distribution were compared (simulation). Finally, the two plans of each patient were irradiated on the corresponding patient-specific 3D printed head phantom using gel dosimetry inserts for one patient and film dosimetry for all three patients. Range differences were extracted from the measured dose distributions. The measured and the simulated range differences were corrected for range differences originating from the initial plans and evaluated. RESULTS The simulation approach showed high agreement with the standard recalculation approach. The median values of the range differences of these two methods agreed within 0.1 mm and the interquartile ranges (IQRs) within 0.3 mm for all three patients. The range differences of the film measurement were accurately matching with the simulation approach in the film plane. The median values of these range differences deviated less than 0.1 mm and the IQRs less than 0.4 mm. For the full 3D evaluation of the gel range differences, the median value and IQR matched those of the simulation approach within 0.7 and 0.5 mm, respectively. scCBCT- and planCT-based dose distributions were found to have a range agreement better than 3 mm (median and IQR) for all considered scenarios (recalculation, simulation, and measurement). CONCLUSIONS The results of this initial study indicate that an online adaptive proton workflow based on scatter-corrected CBCT image data for head irradiations is feasible. The novel presented measurement- and simulation-based method was shown to be equivalent to the standard literature recalculation approach. Additionally, it has the capability to catch effects of image differences on the treatment plan optimization. This makes the measurement-based approach particularly interesting for quality assurance of CBCT-based online adaptive proton therapy. The observed uncertainties could be kept within those of the registration and positioning. The proposed validation could also be applied for other alternative in-room images, e.g. for MR-based pseudoCTs.
Collapse
Affiliation(s)
- Sebastian Neppl
- Department of Radiation Oncology, University Hospital, LMU Munich, 81377, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), 85748, Garching bei München, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, 81377, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), 85748, Garching bei München, Germany
| | - Daniel Köpl
- Rinecker Proton Therapy Center, 81371, Munich, Germany
| | | | - Moritz Schneider
- Department of Radiology, University Hospital, LMU Munich, 81377, Munich, Germany.,Comprehensive Pneumology Center Munich (CPC-M), German Center for Lung Research (DZL), 81377, Munich, Germany
| | - David Bondesson
- Department of Radiology, University Hospital, LMU Munich, 81377, Munich, Germany.,Comprehensive Pneumology Center Munich (CPC-M), German Center for Lung Research (DZL), 81377, Munich, Germany
| | - Moritz Rabe
- Department of Radiation Oncology, University Hospital, LMU Munich, 81377, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), 85748, Garching bei München, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, 81377, Munich, Germany.,German Cancer Consortium (DKTK), Partner site Munich, 81377, Munich, Germany
| | - Olaf Dietrich
- Department of Radiology, University Hospital, LMU Munich, 81377, Munich, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, 81377, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), 85748, Garching bei München, Germany
| | - Katia Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), 85748, Garching bei München, Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, 81377, Munich, Germany
| |
Collapse
|
18
|
Synthetic CT in assessment of anatomical and dosimetric variations in radiotherapy - procedure validation. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2020. [DOI: 10.2478/pjmpe-2020-0022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Abstract
Introduction: One of many procedures to control the quality of radiotherapy is daily imaging of the patient’s anatomy. The CBCT (Cone Beam Computed Tomography) plays an important role in patient positioning, and dose delivery monitoring. Nowadays, CBCT is a baseline for the calculation of fraction and total dose. Thus, it provides the potential for more comprehensive monitoring of the delivered dose and adaptive radiotherapy. However, due to the poor quality and the presence of numerous artifacts, the replacement of the CBCT image with the corrected one is desired for dose calculation. The aim of the study was to validate a method for generating a synthetic CT image based on deformable image registration.
Material and methods: A Head & Torso Freepoint phantom, model 002H9K (Computerized Imaging Reference Systems, Norfolk, USA) with inserts was imaged with CT (Computed Tomography). Then, contouring and treatment plan were created in Eclipse (Varian Medical Systems, Palo Alto, CA, USA) treatment planning system. The phantom was scanned again with the CBCT. The planning CT was registered and deformed to the CBCT, resulting in a synthetic CT in Velocity software (Varian Medical Systems, Palo Alto, CA, USA). The dose distribution was recalculated based on the created CT image.
Results: Differences in structure volumes and dose statistics calculated both on CT and synthetic CT were evaluated. Discrepancies between the original and delivered plan from 0.0 to 2.5% were obtained. Dose comparison was performed on the DVH (Dose-Volume Histogram) for all delineated inserts.
Conclusions: Our findings suggest the potential utility of deformable registration and synthetic CT for providing dose reconstruction. This study reports on the limitation of the procedure related to the limited length of the CBCT volume and deformable fusion inaccuracies.
Collapse
|
19
|
Andersen AG, Park YK, Elstrøm UV, Petersen JBB, Sharp GC, Winey B, Dong L, Muren LP. Evaluation of an a priori scatter correction algorithm for cone-beam computed tomography based range and dose calculations in proton therapy. Phys Imaging Radiat Oncol 2020; 16:89-94. [PMID: 33458349 PMCID: PMC7807858 DOI: 10.1016/j.phro.2020.09.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 09/22/2020] [Accepted: 09/30/2020] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND AND PURPOSE Scatter correction of cone-beam computed tomography (CBCT) projections may enable accurate online dose-delivery estimations in photon and proton-based radiotherapy. This study aimed to evaluate the impact of scatter correction in CBCT-based proton range/dose calculations, in scans acquired in both proton and photon gantries. MATERIAL AND METHODS CBCT projections of a Catphan and an Alderson phantom were acquired on both a proton and a photon gantry. The scatter corrected CBCTs (corrCBCTs) and the clinical reconstructions (stdCBCTs) were compared against CTs rigidly registered to the CBCTs (rigidCTs). The CBCTs of the Catphan phantom were segmented by materials for CT number analysis. Water equivalent path length (WEPL) maps were calculated through the Alderson phantom while proton plans optimized on the rigidCT and recalculated on all CBCTs were compared in a gamma analysis. RESULTS In medium and high-density materials, the corrCBCT CT numbers were much closer to those of the rigidCT than the stdCBCTs. E.g. in the 50% bone segmentations the differences were reduced from above 300 HU (with stdCBCT) to around 60-70 HU (with corrCBCT). Differences in WEPL from the rigidCT were typically well below 5 mm for the corrCBCTs, compared to well above 10 mm for the stdCBCTs with the largest deviations in the head and thorax regions. Gamma pass rates (2%/2mm) when comparing CBCT-based dose re-calculations to rigidCT calculations were improved from around 80% (with stdCBCT) to mostly above 90% (with corrCBCT). CONCLUSION Scatter correction leads to substantial artefact reductions, improving accuracy of CBCT-based proton range/dose calculations.
Collapse
Affiliation(s)
| | | | - Ulrik Vindelev Elstrøm
- Danish Centre for Particle Therapy, Aarhus University Hospital/Aarhus University, Aarhus, Denmark
| | | | - Gregory C. Sharp
- Massachusetts General Hospital/Harvard Medical School, Boston, MA, USA
| | - Brian Winey
- Massachusetts General Hospital/Harvard Medical School, Boston, MA, USA
| | - Lei Dong
- University of Pennsylvania, Philadelphia, PA, USA
| | - Ludvig Paul Muren
- Danish Centre for Particle Therapy, Aarhus University Hospital/Aarhus University, Aarhus, Denmark
| |
Collapse
|
20
|
Cupping artifacts correction for polychromatic X-ray cone-beam computed tomography based on projection compensation and hardening behavior. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2019.101823] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
21
|
Kurz C, Maspero M, Savenije MHF, Landry G, Kamp F, Pinto M, Li M, Parodi K, Belka C, van den Berg CAT. CBCT correction using a cycle-consistent generative adversarial network and unpaired training to enable photon and proton dose calculation. Phys Med Biol 2019; 64:225004. [PMID: 31610527 DOI: 10.1088/1361-6560/ab4d8c] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
In presence of inter-fractional anatomical changes, clinical benefits are anticipated from image-guided adaptive radiotherapy. Nowadays, cone-beam CT (CBCT) imaging is mostly utilized during pre-treatment imaging for position verification. Due to various artifacts, image quality is typically not sufficient for photon or proton dose calculation, thus demanding accurate CBCT correction, as potentially provided by deep learning techniques. This work aimed at investigating the feasibility of utilizing a cycle-consistent generative adversarial network (cycleGAN) for prostate CBCT correction using unpaired training. Thirty-three patients were included. The network was trained to translate uncorrected, original CBCT images (CBCTorg) into planning CT equivalent images (CBCTcycleGAN). HU accuracy was determined by comparison to a previously validated CBCT correction technique (CBCTcor). Dosimetric accuracy was inferred for volumetric-modulated arc photon therapy (VMAT) and opposing single-field uniform dose (OSFUD) proton plans, optimized on CBCTcor and recalculated on CBCTcycleGAN. Single-sided SFUD proton plans were utilized to assess proton range accuracy. The mean HU error of CBCTcycleGAN with respect to CBCTcor decreased from 24 HU for CBCTorg to -6 HU. Dose calculation accuracy was high for VMAT, with average pass-rates of 100%/89% for a 2%/1% dose difference criterion. For proton OSFUD plans, the average pass-rate for a 2% dose difference criterion was 80%. Using a (2%, 2 mm) gamma criterion, the pass-rate was 96%. 93% of all analyzed SFUD profiles had a range agreement better than 3 mm. CBCT correction time was reduced from 6-10 min for CBCTcor to 10 s for CBCTcycleGAN. Our study demonstrated the feasibility of utilizing a cycleGAN for CBCT correction, achieving high dose calculation accuracy for VMAT. For proton therapy, further improvements may be required. Due to unpaired training, the approach does not rely on anatomically consistent training data or potentially inaccurate deformable image registration. The substantial speed-up for CBCT correction renders the method particularly interesting for adaptive radiotherapy.
Collapse
Affiliation(s)
- Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany. Department of Radiotherapy, Center for Image Sciences, Universitair Medisch Centrum Utrecht, Utrecht, the Netherlands. Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), Garching, Germany. Author to whom correspondence should be addressed
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Thorwarth D. Imaging science and development in modern high-precision radiotherapy. Phys Imaging Radiat Oncol 2019; 12:63-66. [PMID: 33458297 PMCID: PMC7807660 DOI: 10.1016/j.phro.2019.11.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Germany
| |
Collapse
|
23
|
Niepel K, Kamp F, Kurz C, Hansen D, Rit S, Neppl S, Hofmaier J, Bondesson D, Thieke C, Dinkel J, Belka C, Parodi K, Landry G. Feasibility of 4DCBCT-based proton dose calculation: An ex vivo porcine lung phantom study. Z Med Phys 2019; 29:249-261. [DOI: 10.1016/j.zemedi.2018.10.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 09/06/2018] [Accepted: 10/22/2018] [Indexed: 12/25/2022]
|
24
|
Liang X, Chen L, Nguyen D, Zhou Z, Gu X, Yang M, Wang J, Jiang S. Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy. Phys Med Biol 2019; 64:125002. [PMID: 31108465 DOI: 10.1088/1361-6560/ab22f9] [Citation(s) in RCA: 142] [Impact Index Per Article: 28.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Throughout the course of delivering a radiation therapy treatment, which may take several weeks, a patient's anatomy may change drastically, and adaptive radiation therapy (ART) may be needed. Cone-beam computed tomography (CBCT), which is often available during the treatment process, can be used for both patient positioning and ART re-planning. However, due to the prominent amount of noise, artifacts, and inaccurate Hounsfield unit (HU) values, the dose calculation based on CBCT images could be inaccurate for treatment planning. One way to solve this problem is to convert CBCT images to more accurate synthesized CT (sCT) images. In this work, we have developed a cycle-consistent generative adversarial network framework (CycleGAN) to synthesize CT images from CBCT images. This model is capable of image-to-image translation using unpaired CT and CBCT images in an unsupervised learning setting. The sCT images generated from CBCT through this CycleGAN model are visually and quantitatively similar to real CT images with decreased mean absolute error (MAE) from 69.29 HU to 29.85 HU for head-and-neck (H&N) cancer patients. The dose distributions calculated on the sCT by CycleGAN demonstrated a higher accuracy than those on CBCT in a 3D gamma index analysis with increased gamma index pass rate from 86.92% to 96.26% under 1 mm/1% criteria, when using the deformed planning CT image (dpCT) as the reference. We also compared the CycleGAN model with other unsupervised learning methods, including deep convolutional generative adversarial networks (DCGAN) and progressive growing of GANs (PGGAN), and demonstrated that CycleGAN outperformed the other two models. A phantom study has been conducted to compare sCT with dpCT, and the increase of structural similarity index from 0.91 to 0.93 shows that CycleGAN performed better than DIR in terms of preserving anatomical accuracy.
Collapse
Affiliation(s)
- Xiao Liang
- Department of Radiation Oncology, Medical Artificial Intelligence and Automation Laboratory, University of Texas Southwestern Medical Center, Dallas, TX, United States of America. Co-first authors
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Landry G, Hansen D, Kamp F, Li M, Hoyle B, Weller J, Parodi K, Belka C, Kurz C. Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations. Phys Med Biol 2019; 64:035011. [PMID: 30523998 DOI: 10.1088/1361-6560/aaf496] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Image intensity correction is crucial to enable cone beam computed tomography (CBCT) based radiotherapy dose calculations. This study evaluated three different deep learning based correction methods using a U-shaped convolutional neural network architecture (Unet) in terms of their photon and proton dose calculation accuracy. CT and CBCT imaging data of 42 prostate cancer patients were included. For target ground truth data generation, a CBCT correction method based on CT to CBCT deformable image registration (DIR) was used. The method yields a deformed CT called (i) virtual CT (vCT) which is used to generate (ii) corrected CBCT projections allowing the reconstruction of (iii) a final corrected CBCT image. The single Unet architecture was trained using these three different datasets: (Unet1) raw and corrected CBCT projections, (Unet2) raw CBCT and vCT image slices and (Unet3) raw and reference corrected CBCT image slices. Volumetric arc therapy (VMAT) and proton pencil beam scanning (PBS) single field uniform dose (SFUD) plans were optimized on the reference corrected image and recalculated on the obtained Unet-corrected CBCT images. The mean error (ME) and mean absolute error (MAE) for Unet1/2/3 were [Formula: see text] Hounsfield units (HU) and [Formula: see text] HU. The 1% dose difference pass rates were better than 98.4% for VMAT for 8 test patients not seen during training, with little difference between Unets. Gamma evaluation results were even better. For protons a gamma evaluation was employed to account for small range shifts, and [Formula: see text] mm pass rates for Unet1/2/3 were better than [Formula: see text] and 91%. A 3 mm range difference threshold was established. Only for Unet3 the 5th and 95th percentiles of the range difference distributions over all fields, test patients and dose profiles were within this threshold. A single Unet architecture was successfully trained using both CBCT projections and CBCT image slices. Since the results of the other Unets were poorer than Unet3, we conclude that training using corrected CBCT image slices as target data is optimal for PBS SFUD proton dose calculations, while for VMAT all Unets provided sufficient accuracy.
Collapse
Affiliation(s)
- Guillaume Landry
- Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), Garching, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Hansen DC, Landry G, Kamp F, Li M, Belka C, Parodi K, Kurz C. ScatterNet: A convolutional neural network for cone‐beam CT intensity correction. Med Phys 2018; 45:4916-4926. [DOI: 10.1002/mp.13175] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 07/05/2018] [Accepted: 08/29/2018] [Indexed: 12/25/2022] Open
Affiliation(s)
- David C. Hansen
- Department of Medical Physics Aarhus University Hospital Aarhus 8200Denmark
| | - Guillaume Landry
- Department of Medical Physics Faculty of Physics Ludwig‐Maximilians‐Universität München (LMU Munich) Garching bei München 85748Germany
| | - Florian Kamp
- Department of Radiation Oncology University Hospital LMU Munich Munich 81377Germany
| | - Minglun Li
- Department of Radiation Oncology University Hospital LMU Munich Munich 81377Germany
| | - Claus Belka
- Department of Radiation Oncology University Hospital LMU Munich Munich 81377Germany
- German Cancer Consortium (DKTK) Munich Germany
| | - Katia Parodi
- Department of Medical Physics Faculty of Physics Ludwig‐Maximilians‐Universität München (LMU Munich) Garching bei München 85748Germany
| | - Christopher Kurz
- Department of Medical Physics Faculty of Physics Ludwig‐Maximilians‐Universität München (LMU Munich) Garching bei München 85748Germany
- Department of Radiation Oncology University Hospital LMU Munich Munich 81377Germany
| |
Collapse
|
27
|
van Elmpt W. Quantitative computed tomography in radiation therapy: A mature technology with a bright future. Phys Imaging Radiat Oncol 2018; 6:12-13. [PMID: 33458382 PMCID: PMC7807762 DOI: 10.1016/j.phro.2018.04.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Affiliation(s)
- Wouter van Elmpt
- Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Developmental Biology, Maastricht University Medical Centre, Dr. Tanslaan 12, NL-6229 ET Maastricht, The Netherlands
| |
Collapse
|