Keenan KE, Jordanova KV, Ogier SE, Tamada D, Bruhwiler N, Starekova J, Riek J, McCracken PJ, Hernando D. Phantoms for Quantitative Body MRI: a review and discussion of the phantom value. MAGMA (NEW YORK, N.Y.) 2024; 37:535-549. [PMID: 38896407 PMCID: PMC11417080 DOI: 10.1007/s10334-024-01181-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 05/18/2024] [Accepted: 06/11/2024] [Indexed: 06/21/2024]
Abstract
In this paper, we review the value of phantoms for body MRI in the context of their uses for quantitative MRI methods research, clinical trials, and clinical imaging. Certain uses of phantoms are common throughout the body MRI community, including measuring bias, assessing reproducibility, and training. In addition to these uses, phantoms in body MRI methods research are used for novel methods development and the design of motion compensation and mitigation techniques. For clinical trials, phantoms are an essential part of quality management strategies, facilitating the conduct of ethically sound, reliable, and regulatorily compliant clinical research of both novel MRI methods and therapeutic agents. In the clinic, phantoms are used for development of protocols, mitigation of cost, quality control, and radiotherapy. We briefly review phantoms developed for quantitative body MRI, and finally, we review open questions regarding the most effective use of a phantom for body MRI.
Collapse
Affiliation(s)
- Kathryn E Keenan
- Physical Measurement Laboratory, National Institute of Standards and Technology, NIST, 325 Broadway, Boulder, CO, 80305, USA.
| | - Kalina V Jordanova
- Physical Measurement Laboratory, National Institute of Standards and Technology, NIST, 325 Broadway, Boulder, CO, 80305, USA
| | - Stephen E Ogier
- Physical Measurement Laboratory, National Institute of Standards and Technology, NIST, 325 Broadway, Boulder, CO, 80305, USA
- Department of Physics, University of Colorado Boulder, Boulder, CO, USA
| | | | - Natalie Bruhwiler
- Physical Measurement Laboratory, National Institute of Standards and Technology, NIST, 325 Broadway, Boulder, CO, 80305, USA
| | | | | | | | | |
Collapse
|
2
|
Poulin E, Lacroix F, Archambault L, Jutras JD. Commissioning and implementing a Quality Assurance program for dedicated radiation oncology MRI scanners. J Appl Clin Med Phys 2024; 25:e14185. [PMID: 38332556 DOI: 10.1002/acm2.14185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 09/20/2023] [Accepted: 10/05/2023] [Indexed: 02/10/2024] Open
Abstract
PURPOSE ACR and AAPM task group's guidelines addressing commissioning for dedicated MR simulators were recently published. The goal of the current paper is to present the authors' 2-year experience regarding the commissioning and introduction of a QA program based on these guidelines and an associated automated workflow. METHODS All mandatory commissioning tests suggested by AAPM report 284 were performed and results are reported for two MRI scanners (MAGNETOM Sola and Aera). Visual inspection, vendor clinical or service platform, third-party software, or in-house python-based code were used. Automated QA and data analysis was performed via vendor, in-house or third-party software. QATrack+ was used for QA data logging and storage. 3D geometric distortion, B0 inhomogeneity, EPI, and parallel imaging performance were evaluated. RESULTS Contrasting with AAPM report 284 recommendations, homogeneity and RF tests were performed monthly. The QA program allowed us to detect major failures over time (shimming, gradient calibration and RF interference). Automated QA, data analysis, and logging allowed fast ACR analysis daily and monthly QA to be performed in 3 h. On the Sola, the average distortion is 1 mm for imaging radii of 250 mm or less. For radii of up to 200 mm, the maximum, average (standard deviation) distortion is 1.2 and 0.4 mm (0.3 mm). Aera values are roughly double the Sola for radii up to 200 mm. EPI geometric distortion, ghosting ratio, and long-term stability were found to be under the maximum recommended values. Parallel imaging SNR ratio was stable and close to the theoretical value (ideal g-factor). No major failures were detected during commissioning. CONCLUSION An automated workflow and enhanced QA program allowed to automatically track machine and environmental changes over time and to detect periodic failures and errors that might otherwise have gone unnoticed. The Sola is more geometrically accurate, with a more homogenous B0 field than the Aera.
Collapse
Affiliation(s)
- Eric Poulin
- Département de physique, de génie physique et d'optique et Centre de recherche sur le cancer de l'Université Laval, Université Laval, Québec, Canada
- Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec-Université Laval, Québec, Canada
| | - Frederic Lacroix
- Département de physique, de génie physique et d'optique et Centre de recherche sur le cancer de l'Université Laval, Université Laval, Québec, Canada
- Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec-Université Laval, Québec, Canada
| | - Louis Archambault
- Département de physique, de génie physique et d'optique et Centre de recherche sur le cancer de l'Université Laval, Université Laval, Québec, Canada
- Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec-Université Laval, Québec, Canada
| | - Jean-David Jutras
- Département de physique, de génie physique et d'optique et Centre de recherche sur le cancer de l'Université Laval, Université Laval, Québec, Canada
- Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec-Université Laval, Québec, Canada
| |
Collapse
|
3
|
Riis HL, Chick J, Dunlop A, Tilly D. The Quality Assurance of a 1.5 T MR-Linac. Semin Radiat Oncol 2024; 34:120-128. [PMID: 38105086 DOI: 10.1016/j.semradonc.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
The recent introduction of a commercial 1.5 T MR-linac system has considerably improved the image quality of the patient acquired in the treatment unit as well as enabling online adaptive radiation therapy (oART) treatment strategies. Quality Assurance (QA) of this new technology requires new methodology that allows for the high field MR in a linac environment. The presence of the magnetic field requires special attention to the phantoms, detectors, and tools to perform QA. Due to the design of the system, the integrated megavoltage imager (MVI) is essential for radiation beam calibrations and QA. Additionally, the alignment between the MR image system and the radiation isocenter must be checked. The MR-linac system has vendor-supplied phantoms for calibration and QA tests. However, users have developed their own routine QA systems to independently check that the machine is performing as required, as to ensure we are able to deliver the intended dose with sufficient certainty. The aim of this work is therefore to review the MR-linac specific QA procedures reported in the literature.
Collapse
Affiliation(s)
- Hans Lynggaard Riis
- Department of Oncology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.
| | - Joan Chick
- The Joint Department of Physics, The Royal Marsden Hospital and the Institute of Cancer Research, London, UK
| | - Alex Dunlop
- The Joint Department of Physics, The Royal Marsden Hospital and the Institute of Cancer Research, London, UK
| | - David Tilly
- Department of Immunology, Genetics and Pathology, Medical Radiation Physics, Uppsala University, Uppsala, Sweden; Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
4
|
Wyatt JJ, Pearson RA, Frew J, Walker C, Richmond N, Wilkinson M, Wilkes K, Driver S, West S, Karen P, Brooks-Pearson RL, Ainslie D, Wilkins E, McCallum HM. The first patients treated with MR-CBCT soft-tissue matching in a MR-only prostate radiotherapy pathway. Radiography (Lond) 2023; 29:347-354. [PMID: 36736147 DOI: 10.1016/j.radi.2023.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 01/16/2023] [Accepted: 01/19/2023] [Indexed: 02/05/2023]
Abstract
INTRODUCTION Magnetic Resonance (MR)-only radiotherapy for prostate cancer has previously been reported using fiducial markers for on-treatment verification. MR-Cone Beam Computed Tomography (CBCT) soft-tissue matching does not require invasive fiducial markers and enables MR-only treatments to other pelvic cancers. This study evaluated the first clinical implementation of MR-only prostate radiotherapy using MR-CBCT soft-tissue matching. METHODS Twenty prostate patients were treated with MR-only radiotherapy using a synthetic (s)CT-optimised plan with MR-CBCT soft-tissue matching. Two MR sequences were acquired: small Field Of View (FOV) for target delineation and large FOV for organs at risk delineation, sCT generation and on-treatment verification. Patients also received a CT for validation. The prostate was independently contoured on the small FOV MR, copied to the registered CT and modified if there were MR-CT soft-tissue alignment differences (MR-CT volume). This was compared to the MR-only volume with a paired t-test. The treatment plan was recalculated on CT and the doses compared. Independent offline CT-CBCT matches for 5/20 fractions were performed by three therapeutic radiographers using the MR-only contours and compared to the online MR-CBCT matches using two one-sided paired t-tests for equivalence within ±1 mm. RESULTS The MR-only volumes were significantly smaller than MR-CT (p = 0.003), with a volume ratio 0.92 ± 0.02 (mean ± standard error). The sCT isocentre dose difference to CT was 0.2 ± 0.1%. MR-CBCT soft-tissue matching was equivalent to CT-CBCT (p < 0.001), with differences of 0.1 ± 0.2 mm (vertical), -0.1 ± 0.2 mm (longitudinal) and 0.0 ± 0.1 mm (lateral). CONCLUSIONS MR-only radiotherapy with soft-tissue matching has been successfully clinically implemented. It produced significantly smaller target volumes with high dosimetric and on-treatment matching accuracy. IMPLICATIONS FOR PRACTICE MR-only prostate radiotherapy can be safely delivered without using invasive fiducial markers. This enables MR-only radiotherapy to be extended to other pelvic cancers where fiducial markers cannot be used.
Collapse
Affiliation(s)
- J J Wyatt
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK; Translational and Clinical Research Institute, Newcastle University, Newcastle, UK.
| | - R A Pearson
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK; Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
| | - J Frew
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - C Walker
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - N Richmond
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - M Wilkinson
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - K Wilkes
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - S Driver
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - S West
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - P Karen
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - R L Brooks-Pearson
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - D Ainslie
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - E Wilkins
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - H M McCallum
- Northern Centre for Cancer Care, Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK; Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
| |
Collapse
|
5
|
Nousiainen K, Mäkelä T, Peltonen JI. Characterizing geometric distortions of 3D sequences in clinical head MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS, BIOLOGY AND MEDICINE 2022; 35:983-995. [PMID: 35657535 PMCID: PMC9596562 DOI: 10.1007/s10334-022-01020-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 04/20/2022] [Accepted: 05/12/2022] [Indexed: 11/25/2022]
Abstract
Objective Phantoms are often used to estimate the geometric accuracy in magnetic resonance imaging (MRI). However, the distortions may differ between anatomical and phantom images. This study aimed to investigate the applicability of a phantom-based and a test-subject-based method in evaluating geometric distortion present in clinical head-imaging sequences. Materials and methods We imaged a 3D-printed phantom and test subjects with two MRI scanners using two clinical head-imaging 3D sequences with varying patient-table positions and receiver bandwidths. The geometric distortions were evaluated through nonrigid registrations: the displaced acquisitions were compared against the ideal isocenter positioning, and the varied bandwidth volumes against the volume with the highest bandwidth. The phantom acquisitions were also registered to a computed tomography scan. Results Geometric distortion magnitudes increased with larger table displacements and were in good agreement between the phantom and test-subject acquisitions. The effect of increased distortions with decreasing receiver bandwidth was more prominent for test-subject acquisitions. Conclusion Presented results emphasize the sensitivity of the geometric accuracy to positioning and imaging parameters. Phantom limitations may become an issue with some sequence types, encouraging the use of anatomical images for evaluating the geometric accuracy.
Collapse
Affiliation(s)
- Katri Nousiainen
- HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
- Department of Physics, University of Helsinki, Helsinki, Finland.
| | - Teemu Mäkelä
- HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
- Department of Physics, University of Helsinki, Helsinki, Finland
| | - Juha I Peltonen
- HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| |
Collapse
|
6
|
Wyatt JJ, McCallum HM, Maxwell RJ. Developing quality assurance tests for simultaneous Positron Emission Tomography - Magnetic Resonance imaging for radiotherapy planning. Phys Imaging Radiat Oncol 2022; 22:28-35. [PMID: 35493852 PMCID: PMC9048159 DOI: 10.1016/j.phro.2022.03.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 03/02/2022] [Accepted: 03/18/2022] [Indexed: 12/05/2022] Open
Abstract
Background and purpose Simultaneous Positron Emission Tomography - Magnetic Resonance (PET-MR) imaging can potentially improve radiotherapy by enabling more accurate tumour delineation and dose painting. The use of PET-MR imaging for radiotherapy planning requires a comprehensive Quality Assurance (QA) programme to be developed. This study aimed to develop the QA tests required and assess their repeatability and stability. Materials and methods QA tests were developed for: MR image quality, MR geometric accuracy, electromechanical accuracy, PET-MR alignment accuracy, Diffusion Weighted (DW)-MR Apparent Diffusion Coefficient (ADC) accuracy and PET Standard Uptake Value (SUV) accuracy. Each test used a dedicated phantom and was analysed automatically or semi-automatically, with in-house software. Repeatability was evaluated by three same-day measurements with independent phantom positions. Stability was assessed through 12 monthly measurements. Results The repeatability Standard Deviations (SDs) of distortion for the MR geometric accuracy test were ⩽ 0.7 mm . The repeatability SDs in ADC difference from reference were ⩽ 3 % for the DW-MR accuracy test. The PET SUV difference from reference repeatability SD was 0.3 % . The stability SDs agreed within 0.6 mm , 1 percentage point and 1.4 percentage points of the repeatability SDs for the geometric, ADC and SUV accuracy tests respectively. There were no monthly trends apparent. These results were representative of the other tests. Conclusions QA Tests for radiotherapy planning PET-MR have been developed. The tests appeared repeatable and stable over a 12-month period. The developed QA tests could form the basis of a QA programme that enables high-quality, robust PET-MR imaging for radiotherapy planning.
Collapse
Affiliation(s)
- Jonathan J. Wyatt
- Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Hazel M. McCallum
- Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Ross J. Maxwell
- Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
| |
Collapse
|
7
|
Brooks RL, McCallum HM, Pearson RA, Pilling K, Wyatt J. Are cone beam CT image matching skills transferrable from planning CT to planning MRI for MR-only prostate radiotherapy? Br J Radiol 2021; 94:20210146. [PMID: 33914617 PMCID: PMC8248228 DOI: 10.1259/bjr.20210146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Objectives: Treatment verification for MR-only planning has focused on fiducial marker matching, however, these are difficult to identify on MR. An alternative is using the MRI for soft-tissue matching with cone beam computed tomography images (MR-CBCT). However, therapeutic radiographers have limited experience of MRI. This study aimed to assess transferability of therapeutic radiographers CT-CBCT prostate image matching skills to MR-CBCT image matching. Methods: 23 therapeutic radiographers with 3 months–5 years’ experience of online daily CT-CBCT soft-tissue matching prostate cancer patients participated. Each observer completed a baseline assessment of 10 CT-CBCT prostate soft-tissue image matches, followed by 10 MR-CBCT prostate soft-tissue image match assessment. A MRI anatomy training intervention was delivered and the 10 MR-CBCT prostate soft-tissue image match assessment was repeated. Limits of agreement were calculated as the disagreement of the observers with mean of all observers. Results: Limits of agreement at CT-CBCT baseline were 2.8 mm, 2.8 mm, 0.7 mm (vertical, longitudinal, lateral). MR-CBCT matches prior to training were 3.3 mm, 3.1 mm, 0.9 mm, and after training 2.6 mm, 2.4 mm, 1.1 mm (vertical, longitudinal, lateral). Results show similar limits of agreement across the assessments, and variation reduced following the training intervention. Conclusion: This suggests therapeutic radiographers’ prostate CBCT image matching skills are transferrable to a MRI planning scan, since MR-CBCT matching has comparable observer variation to CT-CBCT matching. Advances in knowledge: This is the first publication assessing interobserver MR-CBCT prostate soft tissue matching in an MR-only pathway.
Collapse
Affiliation(s)
- Rachel L Brooks
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Hazel M McCallum
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK.,Centre for Cancer, Newcastle University, Newcastle upon Tyne, UK
| | - Rachel A Pearson
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK.,Centre for Cancer, Newcastle University, Newcastle upon Tyne, UK
| | - Karen Pilling
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Jonathan Wyatt
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK.,Centre for Cancer, Newcastle University, Newcastle upon Tyne, UK
| |
Collapse
|
8
|
Kavaluus H, Nousiainen K, Kaijaluoto S, Seppälä T, Saarilahti K, Tenhunen M. Determination of acceptance criteria for geometric accuracy of magnetic resonance imaging scanners used in radiotherapy planning. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2021; 17:58-64. [PMID: 33898780 PMCID: PMC8058029 DOI: 10.1016/j.phro.2021.01.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 01/14/2021] [Accepted: 01/14/2021] [Indexed: 12/23/2022]
Abstract
Geometric accuracy of MRI-scanners in radiotherapy planning must be evaluated. Phantom acquisitions with standard and clinical sequences were performed. Geometric distortions were determined in several volumes of interest. We recommend acceptance criteria for MRI-scanners in radiotherapy planning. Explicit and simple acceptance criteria enable effective regulatory inspections.
Background and Purpose Magnetic resonance imaging is increasingly used in radiotherapy planning; yet, the performance of the utilized scanners is rarely regulated by any authority. The aim of this study was to determine the geometric accuracy of several magnetic resonance imaging scanners used for radiotherapy planning, and to establish acceptance criteria for such scanners. Materials and Methods The geometric accuracy of five different scanners was measured with three sequences using a commercial large-field-of-view phantom. The distortion magnitudes were determined in spherical volumes around the scanner isocenter and in cylindrical volumes along scanner z-axis. The repeatability of the measurements was determined on a single scanner with two quality assurance sequences with three single-setup and seven repeated-setup measurements. Results For all scanners and sequences except one, the mean and median distortion magnitude was <1 mm and <2 mm in spherical volumes with diameters of 400 mm and 500 mm, respectively. For all sequences maximum distortion was <2 mm in spherical volume with diameter of 300 mm. The mean standard deviation of marker-by-marker distortion magnitudes over repeated acquisitions was ≤0.6 mm with both tested sequences. Conclusions All tested scanners were geometrically accurate for their current use in radiotherapy planning. The acceptance criteria of geometric accuracy for regulatory inspections of a supervising authority could be set according to these results.
Collapse
Affiliation(s)
- Henna Kavaluus
- Radiation and Nuclear Safety Authority, STUK, Laippatie 4, FI-00880 Helsinki, Finland.,HUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland.,Department of Physics, University of Helsinki, P.O. Box 64, FI-00014 Helsinki, Finland
| | - Katri Nousiainen
- Radiation and Nuclear Safety Authority, STUK, Laippatie 4, FI-00880 Helsinki, Finland.,HUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland.,Department of Physics, University of Helsinki, P.O. Box 64, FI-00014 Helsinki, Finland.,HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, B.O. Box 340, FI-00029 Helsinki, Finland
| | - Sampsa Kaijaluoto
- Radiation and Nuclear Safety Authority, STUK, Laippatie 4, FI-00880 Helsinki, Finland
| | - Tiina Seppälä
- HUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland
| | - Kauko Saarilahti
- HUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland
| | - Mikko Tenhunen
- HUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland
| |
Collapse
|
9
|
Lerner M, Medin J, Jamtheim Gustafsson C, Alkner S, Siversson C, Olsson LE. Clinical validation of a commercially available deep learning software for synthetic CT generation for brain. Radiat Oncol 2021; 16:66. [PMID: 33827619 PMCID: PMC8025544 DOI: 10.1186/s13014-021-01794-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 03/23/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Most studies on synthetic computed tomography (sCT) generation for brain rely on in-house developed methods. They often focus on performance rather than clinical feasibility. Therefore, the aim of this work was to validate sCT images generated using a commercially available software, based on a convolutional neural network (CNN) algorithm, to enable MRI-only treatment planning for the brain in a clinical setting. METHODS This prospective study included 20 patients with brain malignancies of which 14 had areas of resected skull bone due to surgery. A Dixon magnetic resonance (MR) acquisition sequence for sCT generation was added to the clinical brain MR-protocol. The corresponding sCT images were provided by the software MRI Planner (Spectronic Medical AB, Sweden). sCT images were rigidly registered and resampled to CT for each patient. Treatment plans were optimized on CT and recalculated on sCT images for evaluation of dosimetric and geometric endpoints. Further analysis was also performed for the post-surgical cases. Clinical robustness in patient setup verification was assessed by rigidly registering cone beam CT (CBCT) to sCT and CT images, respectively. RESULTS All sCT images were successfully generated. Areas of bone resection due to surgery were accurately depicted. Mean absolute error of the sCT images within the body contour for all patients was 62.2 ± 4.1 HU. Average absorbed dose differences were below 0.2% for parameters evaluated for both targets and organs at risk. Mean pass rate of global gamma (1%/1 mm) for all patients was 100.0 ± 0.0% within PTV and 99.1 ± 0.6% for the full dose distribution. No clinically relevant deviations were found in the CBCT-sCT vs CBCT-CT image registrations. In addition, mean values of voxel-wise patient specific geometric distortion in the Dixon images for sCT generation were below 0.1 mm for soft tissue, and below 0.2 mm for air and bone. CONCLUSIONS This work successfully validated a commercially available CNN-based software for sCT generation. Results were comparable for sCT and CT images in both dosimetric and geometric evaluation, for both patients with and without anatomical anomalies. Thus, MRI Planner is feasible to use for radiotherapy treatment planning of brain tumours.
Collapse
Affiliation(s)
- Minna Lerner
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden.
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden.
| | - Joakim Medin
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | - Christian Jamtheim Gustafsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden
| | - Sara Alkner
- Department of Clinical Sciences Lund, Oncology and Pathology, Lund University, Lund, Sweden
- Clinic of Oncology, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | | | - Lars E Olsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden
| |
Collapse
|
10
|
Wyatt JJ, Pearson RA, Walker CP, Brooks RL, Pilling K, McCallum HM. Cone beam computed tomography for dose calculation quality assurance for magnetic resonance-only radiotherapy. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2021; 17:71-76. [PMID: 33898782 PMCID: PMC8058023 DOI: 10.1016/j.phro.2021.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 01/19/2021] [Accepted: 01/20/2021] [Indexed: 11/08/2022]
Abstract
Clinical Magnetic Resonance (MR)-only radiotherapy requires a dose quality assurance method. Doses calculated on Cone Beam Computed Tomography (CBCT) were within 2% of MR-only doses calculated using synthetic CT. CBCT with asymmetric dose difference tolerances of [−2%,1%] appears clinically feasible for quality assurance of prostate MR-only radiotherapy.
Background and purpose Magnetic Resonance (MR)-only prostate radiotherapy using synthetic Computed Tomography (sCT) algorithms with high dose accuracy has been clinically implemented. MR images can suffer from geometric distortions so Quality Assurance (QA) using an independent, geometrically accurate, image could be required. The first-fraction Cone Beam CT (CBCT) has demonstrated potential but has not been evaluated in a clinical MR-only pathway. This study evaluated the clinical use of CBCT for dose accuracy QA of MR-only radiotherapy. Materials and methods A total of 49 patients treated with MR-only prostate radiotherapy were divided into two cohorts. Cohort 1 (20 patients) received a back-up CT, whilst Cohort 2 (29 patients) did not. All patients were planned using the sCT and received daily CBCT imaging with MR-CBCT soft-tissue matching. Each CBCT was calibrated using a patient-specific stepwise Hounsfield Units-to-mass density curve. The treatment plan was recalculated on the first-fraction CBCT using the clinically applied soft-tissue match and the doses compared. For Cohort 1 the sCT was rigidly registered to the back-up CT, the plan recalculated and doses compared. Results Mean sCT-CBCT dose difference across both cohorts was -0.6±0.1% (standard error of the mean, range −2.3%,2.3%), with 47/49 patients within [-2%,1%]. The sCT-CBCT dose difference was systematically lower than the sCT-CT by -0.7±0.6% (±95% limits of agreement). The mean sCT-CBCT gamma pass rate (2%/2mm) was 96.1±0.4% (85.4%,99.7%). Conclusions CBCT-based dose accuracy QA for MR-only radiotherapy appears clinically feasible. There was a small systematic sCT-CBCT dose difference implying asymmetric tolerances of [-2%,1%] would be appropriate.
Collapse
Affiliation(s)
- Jonathan J Wyatt
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.,Centre for Cancer, Newcastle University, Newcastle, UK
| | - Rachel A Pearson
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.,Centre for Cancer, Newcastle University, Newcastle, UK
| | - Christopher P Walker
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Rachel L Brooks
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Karen Pilling
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Hazel M McCallum
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.,Centre for Cancer, Newcastle University, Newcastle, UK
| |
Collapse
|
11
|
Drobnitzky M, vom Endt A, Dewdney A. A phantom based laser marking workflow to visually assess geometric image distortion in magnetic resonance guided radiotherapy. Phys Imaging Radiat Oncol 2021; 17:95-99. [PMID: 33898786 PMCID: PMC8058018 DOI: 10.1016/j.phro.2021.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 01/27/2021] [Accepted: 01/28/2021] [Indexed: 11/25/2022] Open
Abstract
Magnetic resonance (MR)-only workflows require quality assurance due to potential dosimetric impacts of using geometry distorted MR images in radiotherapy planning. MR-visible silicone-based fiducials were arranged in regular 3D structures to cover extended imaging volumes. The scanner’s patient marking workflow with a 2-axes movable laser bridge allowed to visually check geometric distortions of each MR reconstructed fiducial against its true position in 3D space. A measurement resolution and uncertainty of the order of 0.5 mm in sagittal and coronal, and 1 mm in transversal direction was found. The proposed workflow required 1 min of evaluation time per fiducial position, and a 9 min 3D MR volume acquisition.
Collapse
|
12
|
Gustafsson CJ, Swärd J, Adalbjörnsson SI, Jakobsson A, Olsson LE. Development and evaluation of a deep learning based artificial intelligence for automatic identification of gold fiducial markers in an MRI-only prostate radiotherapy workflow. Phys Med Biol 2020; 65:225011. [PMID: 33179610 DOI: 10.1088/1361-6560/abb0f9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Identification of prostate gold fiducial markers in magnetic resonance imaging (MRI) images is challenging when CT images are not available, due to misclassifications from intra-prostatic calcifications. It is also a time consuming task and automated identification methods have been suggested as an improvement for both objectives. Multi-echo gradient echo (MEGRE) images have been utilized for manual fiducial identification with 100% detection accuracy. The aim is therefore to develop an automatic deep learning based method for fiducial identification in MRI images intended for MRI-only prostate radiotherapy. MEGRE images from 326 prostate cancer patients with fiducials were acquired on a 3T MRI, post-processed with N4 bias correction, and the fiducial center of mass (CoM) was identified. A 9 mm radius sphere was created around the CoM as ground truth. A deep learning HighRes3DNet model for semantic segmentation was trained using image augmentation. The model was applied to 39 MRI-only patients and 3D probability maps for fiducial location and segmentation were produced and spatially smoothed. In each of the three largest probability peaks, a 9 mm radius sphere was defined. Detection sensitivity and geometric accuracy was assessed. To raise awareness of potential false findings a 'BeAware' score was developed, calculated from the total number and quality of the probability peaks. All datasets, annotations and source code used were made publicly available. The detection sensitivity for all fiducials were 97.4%. Thirty-six out of thirty-nine patients had all fiducial markers correctly identified. All three failed patients generated a user notification using the BeAware score. The mean absolute difference between the detected fiducial and ground truth CoM was 0.7 ± 0.9 [0 3.1] mm. A deep learning method for automatic fiducial identification in MRI images was developed and evaluated with state-of-the-art results. The BeAware score has the potential to notify the user regarding patients where the proposed method is uncertain.
Collapse
Affiliation(s)
- Christian Jamtheim Gustafsson
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden. Department of Translational Sciences, Medical Radiation Physics, Lund University, Malmö, Sweden
| | | | | | | | | |
Collapse
|
13
|
Slagowski JM, Ding Y, Aima M, Wen Z, Fuller CD, Chung C, Debnam JM, Hwang KP, Kadbi M, Szklaruk J, Wang J. A modular phantom and software to characterize 3D geometric distortion in MRI. Phys Med Biol 2020; 65:195008. [PMID: 32531763 PMCID: PMC7772054 DOI: 10.1088/1361-6560/ab9c64] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Magnetic resonance imaging (MRI) offers outstanding soft tissue contrast that may reduce uncertainties in target and organ-at-risk delineation and enable online adaptive image-guided treatment. Spatial distortions resulting from non-linearities in the gradient fields and non-uniformity in the main magnetic field must be accounted for across the imaging field-of-view to prevent systematic errors during treatment delivery. This work presents a modular phantom and software application to characterize geometric distortion (GD) within the large field-of-view MRI images required for radiation therapy simulation. The modular phantom is assembled from a series of rectangular foam blocks containing high-contrast fiducial markers in a known configuration. The modular phantom design facilitates transportation of the phantom between different MR scanners and MR-guided linear accelerators and allows the phantom to be adapted to fit different sized bores or coils. The phantom was evaluated using a 1.5 T MR-guided linear accelerator (MR-Linac) and 1.5 T and 3.0 T diagnostic scanners. Performance was assessed by varying acquisition parameters to induce image distortions in a known manner. Imaging was performed using T1 and T2 weighted pulse sequences with 2D and 3D distortion correction algorithms and the receiver bandwidth (BW) varied as 250-815 Hz pixel-1. Phantom set-up reproducibility was evaluated across independent set-ups. The software was validated by comparison with a non-modular phantom. Average geometric distortion was 0.94 ± 0.58 mm for the MR-Linac, 0.90 ± 0.53 mm for the 1.5 T scanner, and 1.15 ± 0.62 mm for the 3.0 T scanner, for a 400 mm diameter volume-of-interest. GD increased, as expected, with decreasing BW, and with the 2D versus 3D correction algorithm. Differences in GD attributed to phantom set-up were 0.13 mm or less. Differences in GD for the two software applications were less than 0.07 mm. A novel modular phantom was developed to evaluate distortions in MR images for radiation therapy applications.
Collapse
Affiliation(s)
- Jordan M Slagowski
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Alzahrani M, Broadbent DA, Chuter R, Al-Qaisieh B, Jackson S, Michael H, Johnstone RI, Shah S, Wetscherek A, Chick HJ, Wyatt JJ, McCallum HM, Speight R. Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy. Phys Imaging Radiat Oncol 2020; 15:80-84. [PMID: 33163632 PMCID: PMC7607582 DOI: 10.1016/j.phro.2020.07.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 06/27/2020] [Accepted: 07/22/2020] [Indexed: 11/02/2022] Open
Abstract
BACKGROUND AND PURPOSE Magnetic Resonance Imaging (MRI) is increasingly being used in radiotherapy (RT). However, geometric distortions are a known challenge of using MRI in RT. The aim of this study was to demonstrate feasibility of a national audit of MRI geometric distortions. This was achieved by assessing large field of view (FOV) MRI distortions on a number of scanners used clinically for RT. MATERIALS AND METHODS MRI scans of a large FOV MRI geometric distortion phantom were acquired on 11 MRI scanners that are used clinically for RT in the UK. The mean and maximum distortions and variance between scanners were reported at different distances from the isocentre. RESULTS For a small FOV representing a brain (100-150 mm from isocentre) all distortions were < 2 mm except for the maximum distortion of one scanner. For a large FOV representing a head and neck/pelvis (200-250 mm from isocentre) mean distortions were < 2 mm except for one scanner, maximum distortions were > 10 mm in some cases. The variance between scanners was low and was found to increase with distance from isocentre. CONCLUSIONS This study demonstrated feasibility of the technique to be repeated in a country wide geometric distortion audit of all MRI scanners used clinically for RT. Recommendations were made for performing such an audit and how to derive acceptable limits of distortion in such an audit.
Collapse
Affiliation(s)
- Meshal Alzahrani
- Department of Diagnostic Radiology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
- Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - David A Broadbent
- Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Robert Chuter
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Manchester, UK
- Division of Cancer Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Bashar Al-Qaisieh
- Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Steven Jackson
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Manchester, UK
| | - Hutton Michael
- Christie Medical Physics and Engineering (CMPE), The Christie NHS Foundation Trust, Manchester, UK
| | | | - Simon Shah
- Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - Andreas Wetscherek
- Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, London, UK
| | - H. Joan Chick
- Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, London, UK
| | - Jonathan J Wyatt
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
- Centre for Cancer, Newcastle University, Newcastle, UK
| | - Hazel Mhairi McCallum
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
- Centre for Cancer, Newcastle University, Newcastle, UK
| | - Richard Speight
- Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| |
Collapse
|
15
|
Persson E, Jamtheim Gustafsson C, Ambolt P, Engelholm S, Ceberg S, Bäck S, Olsson LE, Gunnlaugsson A. MR-PROTECT: Clinical feasibility of a prostate MRI-only radiotherapy treatment workflow and investigation of acceptance criteria. Radiat Oncol 2020; 15:77. [PMID: 32272943 PMCID: PMC7147064 DOI: 10.1186/s13014-020-01513-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 03/13/2020] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Retrospective studies on MRI-only radiotherapy have been presented. Widespread clinical implementations of MRI-only workflows are however limited by the absence of guidelines. The MR-PROTECT trial presents an MRI-only radiotherapy workflow for prostate cancer using a new single sequence strategy. The workflow incorporated the commercial synthetic CT (sCT) generation software MriPlanner™ (Spectronic Medical, Helsingborg, Sweden). Feasibility of the workflow and limits for acceptance criteria were investigated for the suggested workflow with the aim to facilitate future clinical implementations. METHODS An MRI-only workflow including imaging, post imaging tasks, treatment plan creation, quality assurance and treatment delivery was created with questionnaires. All tasks were performed in a single MR-sequence geometry, eliminating image registrations. Prospective CT-quality assurance (QA) was performed prior treatment comparing the PTV mean dose between sCT and CT dose-distributions. Retrospective analysis of the MRI-only gold fiducial marker (GFM) identification, DVH- analysis, gamma evaluation and patient set-up verification using GFMs and cone beam CT were performed. RESULTS An MRI-only treatment was delivered to 39 out of 40 patients. The excluded patient was too large for the predefined imaging field-of-view. All tasks could successfully be performed for the treated patients. There was a maximum deviation of 1.2% in PTV mean dose was seen in the prospective CT-QA. Retrospective analysis showed a maximum deviation below 2% in the DVH-analysis after correction for rectal gas and gamma pass-rates above 98%. MRI-only patient set-up deviation was below 2 mm for all but one investigated case and a maximum of 2.2 mm deviation in the GFM-identification compared to CT. CONCLUSIONS The MR-PROTECT trial shows the feasibility of an MRI-only prostate radiotherapy workflow. A major advantage with the presented workflow is the incorporation of a sCT-generation method with multi-vendor capability. The presented single sequence approach are easily adapted by other clinics and the general implementation procedure can be replicated. The dose deviation and the gamma pass-rate acceptance criteria earlier suggested was achievable, and these limits can thereby be confirmed. GFM-identification acceptance criteria are depending on the choice of identification method and slice thickness. Patient positioning strategies needs further investigations to establish acceptance criteria.
Collapse
Affiliation(s)
- Emilia Persson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden.
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Inga-Marie Nilssons gata 49, 205 02, Malmö, Sweden.
| | - Christian Jamtheim Gustafsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Inga-Marie Nilssons gata 49, 205 02, Malmö, Sweden
| | - Petra Ambolt
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden
| | - Silke Engelholm
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden
| | - Sofie Ceberg
- Department of Medical Radiation Physics, Lund University, Barngatan 4, 222 85, Lund, Sweden
| | - Sven Bäck
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden
| | - Lars E Olsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Inga-Marie Nilssons gata 49, 205 02, Malmö, Sweden
| | - Adalsteinn Gunnlaugsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, 221 85, Lund, Sweden
| |
Collapse
|
16
|
Adjeiwaah M, Garpebring A, Nyholm T. Sensitivity analysis of different quality assurance methods for magnetic resonance imaging in radiotherapy. Phys Imaging Radiat Oncol 2020; 13:21-27. [PMID: 33458303 PMCID: PMC7807625 DOI: 10.1016/j.phro.2020.03.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 02/27/2020] [Accepted: 03/02/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND AND PURPOSE There are currently no standard quality assurance (QA) methods for magnetic resonance imaging (MRI) in radiotherapy (RT). This work was aimed at evaluating the ability of two QA protocols to detect common events that affect quality of MR images under RT settings. MATERIALS AND METHODS The American College of Radiology (ACR) MRI QA phantom was repeatedly scanned using a flexible coil and action limits for key image quality parameters were derived. Using an exploratory survey, issues that reduce MR image quality were identified. The most commonly occurring events were introduced as provocations to produce MR images with degraded quality. From these images, detection sensitivities of the ACR MRI QA protocol and a commercial geometric accuracy phantom were determined. RESULTS Machine-specific action limits for key image quality parameters set at mean ± 3 σ were comparable with the ACR acceptable values. For the geometric accuracy phantom, provocations from uncorrected gradient nonlinearity effects and a piece of metal in the bore of the scanner resulted in worst distortions of 22.2 mm and 3.4 mm, respectively. The ACR phantom was sensitive to uncorrected signal variations, electric interference and a piece of metal in the bore of the scanner but could not adequately detect individual coil element failures. CONCLUSIONS The ACR MRI QA phantom combined with the large field-of-view commercial geometric accuracy phantom were generally sensitive in identifying some common MR image quality issues. The two protocols when combined may provide a tool to monitor the performance of MRI systems in the radiotherapy environment.
Collapse
Affiliation(s)
- Mary Adjeiwaah
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | | | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| |
Collapse
|
17
|
Sasamoto K, Kanamoto M, Ishida S, Shimada M, Kimura H, Adachi T. [Evaluation of Long-term Fluctuation of Geometric Distortion in MRI for Radiation Therapy Planning by Using an Automatic Analysis Tool]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:705-714. [PMID: 32684563 DOI: 10.6009/jjrt.2020_jjrt_76.7.705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
High tissue contrast in magnetic resonance imaging (MRI) allows better radiotherapy planning. However, geometric distortion in MRI induces inaccuracies affecting such planning, making it necessary to evaluate the characteristics of such geometric distortion. Although many studies have considered geometric distortion, most of these involved measurements performed only a few times. In this study, we evaluated MRI device-specific geometric distortion over long term and measured its variation by using an automatic analysis tool. The result showed that geometric distortion increased with distance from the center along both lateral and longitudinal directions. Specifically, the average distortion rate and average diameter error over the full measurement period increased by up to 1.02% and 1.96 mm, respectively, when using T1 weighted Image (WI) 3D fast spoiled gradient echo (FSPGR) at R15. In the case of T2 WI 2D fast spin echo (FSE) at R15, the standard deviation of the distortion rate and diameter error increased up to 0.38%, 0.72 mm, respectively. We conclude that periodic quality assurance of geometric distortion should be performed in order to maintain geometric distortion within allowable values.
Collapse
Affiliation(s)
| | | | | | | | | | - Toshiki Adachi
- Department of Radiological Technology, Niigata University of Health and Welfare
| |
Collapse
|
18
|
Bird D, Henry AM, Sebag-Montefiore D, Buckley DL, Al-Qaisieh B, Speight R. A Systematic Review of the Clinical Implementation of Pelvic Magnetic Resonance Imaging-Only Planning for External Beam Radiation Therapy. Int J Radiat Oncol Biol Phys 2019; 105:479-492. [PMID: 31271829 DOI: 10.1016/j.ijrobp.2019.06.2530] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 05/22/2019] [Accepted: 06/21/2019] [Indexed: 11/24/2022]
Abstract
The use of magnetic resonance (MR) imaging scans alone for radiation therapy treatment planning (MR-only planning) has been highlighted as one method of improving patient outcomes. Recent technologic advances have meant that introducing MR-only planning to the clinic is becoming a reality, with several specialist radiation therapy clinics using this technique for treatment. As such, substantial efforts are being made to introduce this technique into wide-spread clinical implementation. A systematic review of publications investigating the clinical implementation of pelvic MR-only radiation therapy treatment planning was undertaken following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Medline, Embase, Scopus, Science Direct, Cumulative Index to Nursing and Allied Health Literature, and Web of Science databases were searched (timespan: all years to January 2, 2019). Twenty-six articles met the inclusion criteria. The studies were grouped into the following categories: (1) MR acquisition and synthetic computed tomography generation verification, (2) MR distortion quantification and phantom development, (3) clinical validation of patient treatment positioning in an MR-only workflow, and (4) MR-only commissioning processes. Key conclusions from this review are (1) MR-only planning has been implemented clinically for prostate cancer treatments; (2) a substantial amount of work remains to translate MR-only planning into widespread clinical implementation for all pelvic sites; (3) MR scanner distortions are no longer a barrier to MR-only planning, but they must be managed appropriately; (4) MR-only-based patient positioning verification shows promise, but limited evidence is reported in the literature and further investigation is required; and (5) a number of MR-only commissioning processes have been reported, which can aid centers as they undertake local commissioning; however, this needs to be formalized in guidance from national bodies.
Collapse
Affiliation(s)
- David Bird
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom; Radiotherapy Research Group, Leeds, United Kingdom.
| | - Ann M Henry
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom; Radiotherapy Research Group, Leeds, United Kingdom
| | - David Sebag-Montefiore
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom; Radiotherapy Research Group, Leeds, United Kingdom
| | - David L Buckley
- Biomedical Imaging, University of Leeds, Leeds, United Kingdom
| | - Bashar Al-Qaisieh
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Richard Speight
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| |
Collapse
|
19
|
Wyatt JJ, Brooks RL, Ainslie D, Wilkins E, Raven E, Pilling K, Pearson RA, McCallum HM. The accuracy of Magnetic Resonance - Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy. Phys Imaging Radiat Oncol 2019; 12:49-55. [PMID: 33458295 PMCID: PMC7807576 DOI: 10.1016/j.phro.2019.11.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/15/2019] [Accepted: 11/20/2019] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND AND PURPOSE Magnetic Resonance (MR)-Only radiotherapy requires a method for matching image with on-treatment Cone Beam Computed Tomography (CBCT). This study aimed to investigate the accuracy of MR-CBCT soft-tissue matching for prostate MR-only radiotherapy. MATERIALS AND METHODS Three patient cohorts were used, with all patients receiving MR and CT scans. For the first cohort (10 patients) the first fraction CBCT was automatically rigidly registered to the CT and MR scans and the MR-CT registration predicted using the MR-CBCT and CT-CBCT registrations. This was compared to the automatic MR-CT registration. For the second and third cohorts (five patients each) the first fraction CBCT was independently matched to the CT and MR by four radiographers, the MR-CBCT and CT-CBCT matches compared and the inter-observer variability assessed. The second cohort used a CT-based structure set and the third a MR-based structure set with the MR relabelled as a 'CT'. RESULTS The mean difference between predicted and actual MR-CT registrations was Δ R All = - 0.1 ± 0.2 mm (s.e.m.). Radiographer MR-CBCT registrations were not significantly different to CT-CBCT, with mean differences in soft-tissue match ⩽ 0.2 mm and all except one difference ⩽ 3.3 mm . This was less than the MR-CBCT inter-observer limits of agreement [ 3.5 , 2.4 , 0.9 ] mm (vertical, longitudinal, lateral), which were similar ( ⩽ 0.5 mm ) to CT-CBCT. CONCLUSIONS MR-CBCT soft-tissue matching is not significantly different to CT-CBCT. Relabelling the MR as a 'CT' does not appear to change the automatic registration. This suggests that MR-CBCT soft-tissue matching is feasible and accurate.
Collapse
Affiliation(s)
- Jonathan J. Wyatt
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
- Northern Institute of Cancer Research, Newcastle University, Newcastle, UK
| | - Rachel L. Brooks
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Dean Ainslie
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Emily Wilkins
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Elizabeth Raven
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Karen Pilling
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Rachel A. Pearson
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
- Northern Institute of Cancer Research, Newcastle University, Newcastle, UK
| | - Hazel M. McCallum
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
- Northern Institute of Cancer Research, Newcastle University, Newcastle, UK
| |
Collapse
|
20
|
Thorwarth D. Imaging science and development in modern high-precision radiotherapy. Phys Imaging Radiat Oncol 2019; 12:63-66. [PMID: 33458297 PMCID: PMC7807660 DOI: 10.1016/j.phro.2019.11.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Germany
| |
Collapse
|
21
|
Keesman R, van de Lindt TN, Juan‐Cruz C, van den Wollenberg W, van der Bijl E, Nowee ME, Sonke J, van der Heide UA, Fast MF. Correcting geometric image distortions in slice‐based 4D‐MRI on the MR‐linac. Med Phys 2019; 46:3044-3054. [DOI: 10.1002/mp.13602] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 05/13/2019] [Accepted: 05/13/2019] [Indexed: 12/25/2022] Open
Affiliation(s)
- Rick Keesman
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Tessa N. van de Lindt
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Celia Juan‐Cruz
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Wouter van den Wollenberg
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Erik van der Bijl
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Marlies E. Nowee
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Jan‐Jakob Sonke
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Uulke A. van der Heide
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| | - Martin F. Fast
- Department of Radiation Oncology The Netherlands Cancer Institute Plesmanlaan 121 1066CX Amsterdam The Netherlands
| |
Collapse
|
22
|
Ranta I, Kemppainen R, Keyriläinen J, Suilamo S, Heikkinen S, Kapanen M, Saunavaara J. Quality assurance measurements of geometric accuracy for magnetic resonance imaging-based radiotherapy treatment planning. Phys Med 2019; 62:47-52. [PMID: 31153398 DOI: 10.1016/j.ejmp.2019.04.022] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/29/2019] [Accepted: 04/24/2019] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND Using magnetic resonance imaging (MRI) as the only imaging method for radiotherapy treatment planning (RTP) is becoming more common as MRI-only RTP solutions have evolved. The geometric accuracy of MR images is an essential factor of image quality when determining the suitability of MRI for RTP. The need is therefore clear for clinically feasible quality assurance (QA) methods for the geometric accuracy measurement. MATERIALS AND METHODS This work evaluates long-term stability of geometric accuracy and the validity of a 2D geometric accuracy QA method compared to a prototype 3D method and analysis software in routine QA. The long-term follow-up measurements were conducted on one of the 1.5 T scanners over a period of 19 months using both methods. Inter-scanner variability of geometric distortions was also evaluated in three 1.5 T and three 3 T MRI scanners from a single vendor by using the prototype 3D QA method. RESULTS The geometric accuracy of the magnetic resonance for radiotherapy (MR-RT) platform remained stable within 2 mm at distances of <250 mm from isocenter. All scanners achieved good geometric accuracy with mean geometric distortions of <1 mm at <150 mm and <2 mm at <250 mm from the isocenter. Both measurement methods provided relevant information about geometric distortions. CONCLUSIONS Geometric distortions are often considered a limitation of MRI-only RTP. Results indicate that geometric accuracy of modern scanners remain within acceptable limits by default even after many years of clinical use based on the 3D QA evaluation.
Collapse
Affiliation(s)
- Iiro Ranta
- Department of Physics and Astronomy, University of Turku, Vesilinnantie 5, FI-20014 Turku, Finland; Department of Medical Physics, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland; Department of Oncology and Radiotherapy, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland.
| | | | - Jani Keyriläinen
- Department of Physics and Astronomy, University of Turku, Vesilinnantie 5, FI-20014 Turku, Finland; Department of Medical Physics, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland; Department of Oncology and Radiotherapy, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland
| | - Sami Suilamo
- Department of Medical Physics, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland; Department of Oncology and Radiotherapy, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland
| | - Samuli Heikkinen
- Department of Medical Physics, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland
| | - Mika Kapanen
- Department of Medical Physics, Medical Imaging Center, Tampere University Hospital, P.O. Box 2000, FI-33521 Tampere, Finland; Department of Oncology, Unit of Radiotherapy, Tampere University Hospital, P.O. Box 2000, FI-33521 Tampere, Finland
| | - Jani Saunavaara
- Department of Medical Physics, Turku University Hospital, Hämeentie 11, P.O. Box 52, FI-20521 Turku, Finland
| |
Collapse
|
23
|
Adjeiwaah M, Bylund M, Lundman JA, Söderström K, Zackrisson B, Jonsson JH, Garpebring A, Nyholm T. Dosimetric Impact of MRI Distortions: A Study on Head and Neck Cancers. Int J Radiat Oncol Biol Phys 2018; 103:994-1003. [PMID: 30496879 DOI: 10.1016/j.ijrobp.2018.11.037] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 11/13/2018] [Accepted: 11/19/2018] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate the effect of magnetic resonance (MR) imaging (MRI) geometric distortions on head and neck radiation therapy treatment planning (RTP) for an MRI-only RTP. We also assessed the potential benefits of patient-specific shimming to reduce the magnitude of MR distortions for a 3-T scanner. METHODS AND MATERIALS Using an in-house Matlab algorithm, shimming within entire imaging volumes and user-defined regions of interest were simulated. We deformed 21 patient computed tomography (CT) images with MR distortion fields (gradient nonlinearity and patient-induced susceptibility effects) to create distorted CT (dCT) images using bandwidths of 122 and 488 Hz/mm at 3 T. Field parameters from volumetric modulated arc therapy plans initially optimized on dCT data sets were transferred to CT data to compute a new plan. Both plans were compared to determine the impact of distortions on dose distributions. RESULTS Shimming across entire patient volumes decreased the percentage of voxels with distortions of more than 2 mm from 15.4% to 2.0%. Using the user-defined region of interest (ROI) shimming strategy, (here the Planning target volume (PTV) was the chosen ROI volume) led to increased geometric for volumes outside the PTV, as such voxels within the spinal cord with geometric shifts above 2 mm increased from 11.5% to 32.3%. The worst phantom-measured residual system distortions after 3-dimensional gradient nonlinearity correction within a radial distance of 200 mm from the isocenter was 2.17 mm. For all patients, voxels with distortion shifts of more than 2 mm resulting from patient-induced susceptibility effects were 15.4% and 0.0% using bandwidths of 122 Hz/mm and 488 Hz/mm at 3 T. Dose differences between dCT and CT treatment plans in D50 at the planning target volume were 0.4% ± 0.6% and 0.3% ± 0.5% at 122 and 488 Hz/mm, respectively. CONCLUSIONS The overall effect of MRI geometric distortions on data used for RTP was minimal. Shimming over entire imaging volumes decreased distortions, but user-defined subvolume shimming introduced significant errors in nearby organs and should probably be avoided.
Collapse
Affiliation(s)
- Mary Adjeiwaah
- Department of Radiation Sciences, Umeå University, Umeå, Sweden.
| | - Mikael Bylund
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Josef A Lundman
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | | | | | | | | | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| |
Collapse
|