1
|
Eggmann F, Orta AL, Abdulmajeed A, Att W, Beuer F, Bergler M, Blatz MB, Brief J, Castro VE, Cooper LF, Han S, Ortiz MA, Paravina RD, Pizzi P, Tholey MJ, Conejo J. Interdisciplinary Delphi study by PROSEC North America: Recommendations on single indirect restorations made from ceramic and nonmetallic biomaterials for posterior teeth. J ESTHET RESTOR DENT 2024. [PMID: 39093128 DOI: 10.1111/jerd.13289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 07/05/2024] [Accepted: 07/18/2024] [Indexed: 08/04/2024]
Abstract
OBJECTIVE This article puts forward consensus recommendations from PROSEC North America regarding single indirect restorations made from ceramic and nonmetallic biomaterials in posterior teeth. OVERVIEW The consensus process involved a multidisciplinary panel and three consensus workshops. A systematic literature review was conducted across five databases to gather evidence. The recommendations, informed by findings from systematic reviews and formulated based on a two-phase e-Delphi survey, emphasize a comprehensive treatment strategy that includes noninvasive measures alongside restorative interventions for managing dental caries and tooth wear. The recommendations advocate for selecting between direct and indirect restorations on a case-by-case basis, favoring inlays and onlays over crowns to align with minimally invasive dentistry principles. The recommendations highlight the critical role of selecting restorative biomaterials based on clinical performance, esthetic properties, and adherence to manufacturer guidelines. They emphasize the importance of precision in restorative procedures, including tooth preparation, impression taking, contamination control, and luting. Regular follow-up and maintenance tailored to individual patient needs are crucial for the longevity of ceramic and nonmetallic restorations. CONCLUSIONS These PROSEC recommendations provide a framework for dental practitioners to deliver high-quality restorative care, advocating for personalized treatment planning and minimally invasive approaches to optimize oral health outcomes. CLINICAL SIGNIFICANCE The PROSEC North America recommendations highlight the importance of minimally invasive techniques in posterior tooth restorations using ceramic and non-metallic biomaterials. These principles prioritize tooth structure conservation and personalized treatment planning, essential for enhancing clinical outcomes and long-term oral health.
Collapse
Affiliation(s)
- Florin Eggmann
- Department of Preventive and Restorative Sciences, Robert Schattner Center, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Periodontology, Endodontology, and Cariology, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Amelia L Orta
- Department of Advanced Oral Sciences and Therapeutics, Division of Prosthodontics, University of Maryland School of Dentistry, University of Maryland, Baltimore, Maryland, USA
- Department of Restorative Sciences, Advanced Education in Prosthodontics, The Dental College of Georgia at Augusta University, Augusta, Georgia, USA
| | - Awab Abdulmajeed
- Department of General Practice and Prosthodontics, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Wael Att
- Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Michael Bergler
- Department of Preventive and Restorative Sciences, Robert Schattner Center, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Markus B Blatz
- Department of Preventive and Restorative Sciences, Robert Schattner Center, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Jakob Brief
- PROSEC gGmbH, Bad Säckingen, Germany
- VITA Zahnfabrik, Bad Säckingen, Germany
| | | | - Lyndon F Cooper
- School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Sean Han
- Master's Arch, Phoenix, Arizona, USA
| | - Miguel A Ortiz
- Department of Restorative Dentistry, University of Illinois College of Dentistry, Chicago, Illinois, USA
| | - Rade D Paravina
- Department of Restorative Dentistry and Prosthodontics, John M. Powers, PhD, Center for Biomaterials and Biomimetics, The University of Texas School of Dentistry at Houston, Houston, Texas, USA
| | - Peter Pizzi
- Pizzi Dental Studio, Staten Island, New York, USA
| | - Michael J Tholey
- PROSEC gGmbH, Bad Säckingen, Germany
- VITA Zahnfabrik, Bad Säckingen, Germany
| | - Julián Conejo
- Department of Preventive and Restorative Sciences, Robert Schattner Center, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
2
|
Jurado CA, Tsujimoto A, Rojas-Rueda S, Mekled S, Alaqeely R, Alsayed HD, Alhotan A. Fracture resistance of ultratranslucent multilayered zirconia veneers with different facial thicknesses. Microsc Res Tech 2024. [PMID: 39003769 DOI: 10.1002/jemt.24649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 05/22/2024] [Accepted: 06/30/2024] [Indexed: 07/16/2024]
Abstract
To assess the fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ultratranslucent multilayered zirconia (5Y-YZP) veneers with varying facial thickness. Sixty translucent zirconia veneers were designed and milled using a chairside CAD/CAM system for maxillary central incisors. The butt joint incisal veneer tooth preparations consisted of 1.00 mm incisal reduction, 0.40 mm chamfer margin, and three different facial reductions; 0.50, 0.75, and 1 mm, respectively. The ceramic veneers were cemented to printed resin dies and subjected to thermal cycling. Subsequently, the restorations were loaded with compressive loading force, and fracture occurrences were recorded. Scanning electron microscope (SEM) images of the fractured specimens were captured. The fracture resistance varied among the veneers with different facial thicknesses. Ultratranslucent zirconia veneers with a facial thickness of 1.00 mm exhibited the highest fracture resistance values (742.15 N), followed by those with 0.75 mm facial thickness (673 N). Minimally invasive veneers with 0.50 mm thickness displayed similar fracture resistance as thicker veneers with 0.75 mm. However, veneers with 1.00 mm thickness displayed the highest values. SEM fracture patterns for 0.50 and 0.75 mm display similar and fewer crack lines than 1.00 mm veneers. RESEARCH HIGHLIGHTS: Minimally invasive zirconia veneers exhibit similar fracture resistance to thicker veneers.
Collapse
Affiliation(s)
- Carlos A Jurado
- Division of Operative Dentistry, Department of General Dentistry, University of Tennessee Health Science Center College of Dentistry, Memphis, Tennessee, USA
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, Aichi Gakuin University School of Dentistry, Nagoya, Japan
- Department of Operative Dentistry, College of Dentistry, University of Iowa, Iowa City, Iowa, USA
- Department of General Dentistry, School of Dentistry, Creighton University, Omaha, Nebraska, USA
| | - Silvia Rojas-Rueda
- Division of Dental Biomaterials, Department of Restorative Sciences, University of Alabama at Birmingham School of Dentistry, Birmingham, Alabama, USA
| | - Salwa Mekled
- Temple University Kornberg School of Dentistry, Philadelphia, Pennsylvania, USA
| | - Razan Alaqeely
- Department of Periodontology and Community Dentsitry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Hussain D Alsayed
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
3
|
Berger L, Matta RE, Weiß CM, Adler W, Wichmann M, Zorzin JI. Effect of Luting Materials on the Accuracy of Fit of Zirconia Copings: A Non-Destructive Digital Analysis Method. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2130. [PMID: 38730936 PMCID: PMC11084802 DOI: 10.3390/ma17092130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 04/26/2024] [Accepted: 04/28/2024] [Indexed: 05/13/2024]
Abstract
The marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation. The copings were luted on the plaster dies (n = 10 per luting material) with a zinc phosphate (A), glass-ionomer (B), self-adhesive resin (C), or resin-modified glass-ionomer cement (D). The accuracy of fit for each coping was assessed using a non-destructive digital method. Intragroup statistical analysis was conducted using Wilcoxon signed rank tests and intergroup analysis by Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Accuracy of fit was significantly different before/after cementation within A (0.033/0.110 µm) and B (0.035/0.118 µm; p = 0.002). A had a significantly increased marginal gap compared to C and D, and B compared to C and D (p ≤ 0.001). Significantly increased vertical discrepancies between A and B versus C and D (p < 0.001) were assessed. Of the materials under investigation, the zinc phosphate cement led to increased vertical marginal discrepancies, whereas the self-adhesive resin cement did not influence the restoration fit.
Collapse
Affiliation(s)
- Lara Berger
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (L.B.); (C.M.W.)
| | - Ragai-Edward Matta
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (L.B.); (C.M.W.)
| | - Christian Markus Weiß
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (L.B.); (C.M.W.)
| | - Werner Adler
- Institute of Medical Informatics, Biometry and Epidemiology (IMBE) of the Friedrich-Alexander-University, Erlangen-Nuremberg, Waldstrasse 6, 91054 Erlangen, Germany;
| | - Manfred Wichmann
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (L.B.); (C.M.W.)
| | - José Ignacio Zorzin
- Dental Clinic 1—Department of Operative Dentistry and Periodontology, Erlangen University Hospital, Glueckstrasse 11, 91054 Erlangen, Germany;
| |
Collapse
|
4
|
Abd Alraheam I, Al-Asmar A, Hasan N, Asoleihat F, Alkayed A. Clinical evaluation of cemented and adhesively resin-bonded monolithic and partially layered zirconia and lithium disilicate crowns. Saudi Dent J 2023; 35:508-514. [PMID: 37520593 PMCID: PMC10373076 DOI: 10.1016/j.sdentj.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 04/03/2023] [Accepted: 04/10/2023] [Indexed: 08/01/2023] Open
Abstract
Purpose Zirconia and lithium disilicate crowns are very popular dental restorations. The cement type and layering technique used can profoundly affect the clinical performance of these crowns.This retrospective study is designed to investigate the success rate of cemented and adhesively bonded monolithic and partially layered zirconia and lithium disilicate crowns placed in faculty practice settings. Materials and Methods Patients who had received zirconia or lithium disilicate crowns at the faculty practice were invited for clinical examination. The examiner used the modified United States Public Health Service (MUSPHS) evaluation criteria to evaluate the crowns. The crowns were either glass ionomer cemented zirconia (GIC-Zr), resin-bonded zirconia (Adh-Zr), or resin-bonded lithium disilicate (Adh-LD). The crowns were also divided into monolithic and layered groups. Inferential analysis was used to examine the differences through bivariate analysis using t-testing and one-way ANOVA. Results Thirty-five patients, with a combined total of 218 single crowns, agreed to participate in the study. No statistically significant differences in the quality outcome variables considered were found between the groups, except for marginal adaptation, where Adh-Zr achieved significantly higher scores compared to GIC-Zr and Adh-LD. Layered zirconia and lithium disilicate crowns have significantly higher quality outcomes in terms of anatomic form, marginal adaptation, and color match compared to monolithic zirconia and lithium disilicate crowns. Conclusions Conventionally cemented zirconia and adhesively bonded zirconia and lithium disilicate crowns are reliable treatment options with high short-term success rates. Clinical studies with longer follow-up times are needed to investigate their long-term success rates.
Collapse
Affiliation(s)
- Islam Abd Alraheam
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Aya Al-Asmar
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Noor Hasan
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Firas Asoleihat
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Awni Alkayed
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| |
Collapse
|
5
|
Mounica Y, Behera S, Arunachalam S, Srikanth L, Deepthi MN, Susmita M. Influence of Different Cements and Cement Thickness on the Stress Distribution under Occlusal Surfaces of Porcelain-fused-to-metal and Porcelain-fused-to-zirconium Crowns: A Finite Element Analysis. J Contemp Dent Pract 2022; 23:1224-1229. [PMID: 37125520 DOI: 10.5005/jp-journals-10024-3448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
AIM The purpose of this study is to compare and evaluate the influence of two different cement space settings and two different cement types on the stress distribution under occlusal surfaces of tooth restored with two different types of crowns and studied by using three-dimensional (3D) finite element analysis (FEA). MATERIALS AND METHODS Eight 3D finite element models (FEMs) representing a mandibular first molar tooth restored with crowns of, porcelain-fused-to-metal (PFM) and porcelain-fused-to-zirconia (PFZ) crowns with two cement space settings (50 and 80 µm) and with two different types of cement were constructed, using an FEA software (ANSYS, version 10). Each model was subjected to a distributed load simulating normal masticatory bite force of 225 N and was applied axial direction. Also, von Mises stress of each individual part in the system of models was calculated. RESULTS The PFM crowns undergo less stress distribution than the PFZ crowns. The PFM crowns are more compatible with self-adhesive cements, and the PFZ crowns are more compatible with resin-modified glass ionomer cements. CONCLUSION The PFM crowns with G-Cem Link Ace with 50 µm and PFZ crowns with RelyX Luting Plus with 80 µm combinations displayed less amount of stress distribution under normal masticatory bite force. CLINICAL SIGNIFICANCE Self-adhesive resin cements with PFM crowns and PFZ with resin-modified glass ionomer cements show more benefits in stress distribution under occlusal surfaces under normal masticatory bite force.
Collapse
Affiliation(s)
- Yasaggari Mounica
- Department of Prosthodontics, Crown and Bridge, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India, Phone: +91 7396490608, e-mail:
| | - Sidhartha Behera
- Department of Prosthodontics, Crown and Bridge, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India
| | - Sudheer Arunachalam
- Department of Prosthodontics, Crown and Bridge, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India
| | - Lankapali Srikanth
- Department of Prosthodontics, Crown and Bridge, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India
| | - Meesala Navya Deepthi
- Department of Prosthodontics, Crown and Bridge, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India
| | - Mondal Susmita
- Department of Prosthodontics, Crown and Bridge, Sree Sai Dental College and Research Institute, Srikakulam, Andhra Pradesh, India
| |
Collapse
|
6
|
Benli M, Turkyilmaz I, Martinez JL, Schwartz S. Clinical performance of lithium disilicate and zirconia CAD/CAM crowns using digital impressions: A systematic review. Prim Dent J 2022; 11:71-76. [PMID: 36533368 DOI: 10.1177/20501684221132941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
PURPOSE The purpose of this systematic review was to compare the clinical performance of lithium disilicate (LDS) and zirconia (Z) single crowns manufactured by computer-aided design/computer-aided manufacturing (CAD/CAM) systems using intraoral optical scanners (IOS). MATERIALS AND METHODS An electronic search for articles published between January 2012 and January 2022 in the English language was performed with the Medline/Pubmed database under the guidelines of Preferred Reporting Items for Systemic Reviews and Meta-analysis (PRISMA). The specific search terms used were "zirconia", "lithium disilicate", "CAD/CAM", "intraoral optical scanner", and "survival". RESULTS The initial electronic search resulted in 278 articles. Most of the resulting articles were excluded, six clinical studies addressing the clinical outcomes of Z and LDS crowns fitted the inclusion criteria and were selected for review. Of these six studies, three were randomised controlled trials, two were retrospective studies, and one was a prospective study. To quantify the clinical performance of the crowns several parameters were recorded, including fractures, endodontic complications, periodontal complications, technical complications, aesthetic complications, and biological complications. It was noted that the most common technical complication of Z and LDS crowns was chipping at a rate of 1.4% and 5% respectively. Regarding Z crowns, aesthetic concerns were the most frequently observed complication. CONCLUSION The outcomes of this systematic review indicate that Z and LDS crowns display a similar incidence of periodontal and endodontic complications when compared to metal-ceramic crowns, suggesting that these all-ceramic materials are viable alternatives. The incidence of chipping was higher in LDS crowns compared to other materials, while Z crowns were inferior in terms of aesthetics.
Collapse
Affiliation(s)
- Merve Benli
- Researcher, University of Pittsburgh, School of Dental Medicine, Department of Oral Biology, Pittsburgh, USA; Assistant Professor, Istanbul University, School of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | - Ilser Turkyilmaz
- Professor, New York University College of Dentistry, Department of Prosthodontics, New York, USA
| | | | | |
Collapse
|
7
|
Connector design effects on the in vitro fracture resistance of 3-unit monolithic prostheses produced from 4 CAD-CAM materials. J Prosthet Dent 2022; 128:1319.e1-1319.e10. [DOI: 10.1016/j.prosdent.2022.09.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 09/26/2022] [Accepted: 09/27/2022] [Indexed: 11/06/2022]
|
8
|
Wear behavior and abrasiveness of monolithic CAD/CAM ceramics after simulated mastication. Clin Oral Investig 2022; 26:6593-6605. [PMID: 35819543 PMCID: PMC9643261 DOI: 10.1007/s00784-022-04611-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 06/28/2022] [Indexed: 11/30/2022]
Abstract
Objectives To evaluate the wear resistance and abrasiveness of monolithic CAD/CAM ceramics. Materials and methods Rectangular-shaped specimens (12 mm × 6.5 mm × 1.5 mm) were sectioned from the following CAD/CAM blocks (n = 10); partially crystallized lithium disilicate (PLD), experimental fully crystallized lithium disilicate (FLD), zirconia-reinforced lithium silicate (ZLS), super-translucent monolithic zirconia (SMZ), and ultra-translucent monolithic zirconia (UMZ). Silicon carbide papers were used to mechanically flatten and polish the surfaces. PLD specimens were subjected to a combined crystallization/glazing firing cycle. Ceramic specimens were mounted to the wear device and tested for 200,000 cycles against human premolars at 20 N force and 2 mm sliding distance. Artificial saliva was used as a lubricant. The teeth were scanned using micro-CT before and after the wear test and the generated models were overlapped to determine the volumetric tooth loss. Before and after the test, specimens’ weights and surface roughness (Ra) values were measured, and the differences were calculated. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) were utilized for microstructural and chemical analysis. Statistical analysis was performed using one-way ANOVA or an equivalent test for non-parametric results. Significance level was set at P ≤ 0.05. Results The type of ceramic material affected the ceramic and antagonist wear rates (P < 0.001). PLD and ZLS had the highest ceramic and antagonist wear, whereas UMZ and SMZ demonstrated the lowest wear values. The FLD group showed comparable antagonist wear and significantly less ceramic wear than PLD and ZLS. Conclusions Monolithic zirconia demonstrated the best wear resistance and least abrasiveness to the antagonist. The experimental lithium disilicate was more wear-resistant than other glass–ceramic groups. Clinical relevance Monolithic zirconia is wear-resistant and gentle on the antagonist. In contrast, glass–ceramics are more abrasive to enamel. Supplementary Information The online version contains supplementary material available at 10.1007/s00784-022-04611-w.
Collapse
|
9
|
Alshehri HA, Altaweel SM, Alshaibani R, Alahmari EA, Alotaibi HN, Alfouzan AF, Labban N. Effect of Different Wax Pattern Manufacturing Techniques on the Marginal Fit of Lithium Disilicate Crowns. MATERIALS 2022; 15:ma15144774. [PMID: 35888241 PMCID: PMC9319464 DOI: 10.3390/ma15144774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Revised: 07/04/2022] [Accepted: 07/05/2022] [Indexed: 02/01/2023]
Abstract
Purpose: The present study evaluated the marginal gap of lithium disilicate crowns fabricated through three different wax pattern techniques; Conventional, Milling and 3D-printing. Materials and Methods: Thirty stone models were replicated from a stainless-steel model representing a prepared tooth; ten were sent to make conventional wax patterns while the remaining were sent to a digital dental scanner. The computer aided design was completed and STL (Standard Tessellation Language) files were sent to either milling or 3D-printing machines. All wax patterns (n = 30) were pressed, and a stabilizing instrument was used to secure the crowns on the master model. The marginal gap was measured at 18 points for each crown using a digital microscope (µm) (n = 540) and compared using One-way ANOVA (p ≤ 0.05). Results: There was a significant difference in the marginal gap value between all three groups (p < 0.01) where the milled group showed the least mean gap (28.87 ± 30.18 µm), followed by 3D printed (47.85 ± 27.44 µm), while the highest mean marginal gap was found in the conventional group (63.49 ± 28.05 µm). Conclusion: Milled and 3D-printed wax patterns produced better fitting crowns compared to conventional techniques.
Collapse
|
10
|
Sadeqi HA, Baig MR, Al-Shammari M. Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems. MATERIALS 2021; 14:ma14216346. [PMID: 34771872 PMCID: PMC8585271 DOI: 10.3390/ma14216346] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 10/15/2021] [Accepted: 10/20/2021] [Indexed: 11/24/2022]
Abstract
Fit accuracy and fracture strength of milled monolithic zirconia (Zi) and zirconia-reinforced lithium silicate (ZLS) crowns are important parameters determining the success of these restorations. This study aimed to evaluate and compare the marginal and internal fit of monolithic Zi and ZLS crowns, along with the fracture load, with and without mechanical aging. Thirty-two stone dies acquired from a customized master metal molar die were scanned, and ceramic crowns (16 Zi Ceramill Zolid HT+ and 16 ZLS Vita Suprinity) were designed and milled. Absolute marginal discrepancies (AMD), marginal gaps (MG), and internal gaps (IG) of the crowns, in relation to the master metal die, were evaluated using x-ray nanotomography (n = 16). Next, thirty-two metal dies were fabricated based on the master metal die, and crowns (16 Zi; 16 ZLS) cemented and divided into four groups of eight each; eight Zi with mechanical aging (MA), eight Zi without mechanical aging (WMA), eight ZLS (MA), and eight ZLS (WMA). Two groups of crowns (Zi-MA; ZLS-MA) were subjected to 500,000 mechanical cycles (200 ± 50 N, 10 Hz) followed by axial compressive strength testing of all crowns, until failure, and the values were recorded. Independent sample t tests (α = 0.05) revealed no significant differences between Zi and ZLS crowns (p > 0.05); for both internal and marginal gaps, however, there were significant differences in AMD (p < 0.005). Independent samples Mann–Whitney U and Kruskal–Wallis tests revealed significant differences between the two materials, Zi and ZLS, regardless of fatigue loading, and for the individual material groups based on aging (α = 0.05). Multiple comparisons using Bonferroni post-hoc analysis showed significant differences between Zi and ZLS material groups, with or without aging. Within the limitations of this study, the ZLS crown fit was found to be on par with Zi, except for the AMD parameter. As regards fracture resistance, both materials survived the normal range of masticatory forces, but the Zi crowns demonstrated greater resistance to fracture. The monolithic Zi and ZLS crowns seem suitable for clinical application, based on the fit and fracture strength values obtained.
Collapse
Affiliation(s)
- Haneen A. Sadeqi
- Department of Bioclinical Sciences, Faculty of Dentistry, Kuwait University, P.O. Box 24923,
Safat 13110, Kuwait; (H.A.S.); (M.A.-S.)
| | - Mirza Rustum Baig
- Department of Restorative Sciences (Prosthodontics), Faculty of Dentistry, Kuwait University, P.O. Box 24923,
Safat 13110, Kuwait
- Correspondence:
| | - Mohammad Al-Shammari
- Department of Bioclinical Sciences, Faculty of Dentistry, Kuwait University, P.O. Box 24923,
Safat 13110, Kuwait; (H.A.S.); (M.A.-S.)
| |
Collapse
|
11
|
Tachibana K, Atsuta I, Tsukiyama Y, Kuwatsuru R, Morita T, Yoshimatsu H, Matsushita Y, Narimatsu I, Ayukawa Y, Sawae Y, Koyano K. The need for polishing and occlusal adjustment of zirconia prostheses for wear on antagonist teeth. Dent Mater J 2021; 40:650-656. [PMID: 33456027 DOI: 10.4012/dmj.2020-190] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The attrition of enamel when opposed by ceramics is of great concern. The purpose of this study was to evaluate enamel wear against high translucent zirconia (Zr), lithium disilicate (LD), gold (Au), and enamel (E) with different surface and contact conditions. The materials were divided into two groups: polished and ground (n=8 each). Two-body wear tests were performed against human enamel with vertical and horizontal, horizontal, and vertical repetitive movements as experiments 1 to 3 respectively. The surface roughness of all materials except Zr changed throughout the experiments. In experiment 1, Zr and Au showed less antagonist wear when polished than when ground. In experiment 2, polished groups showed less antagonist wear than ground groups in all materials. In experiment 3, Zr and LD exerted greater antagonist wear than E, regardless of Ra. These findings confirm the importance of polishing and occlusal adjustment of zirconia.
Collapse
Affiliation(s)
- Keishu Tachibana
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Ikiru Atsuta
- Division of Advanced Dental Devices and Therapeutics, Faculty of Dental Science, Kyushu University
| | - Yoshihiro Tsukiyama
- Section of Dental Education, Division of Oral Biological Sciences, Faculty of Dental Science, Kyushu University
| | - Rika Kuwatsuru
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Takehiro Morita
- Machine Elements and Design Laboratory, Department of Mechanical Engineering, Kyushu University
| | | | - Yasuyuki Matsushita
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Ikue Narimatsu
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Yasunori Ayukawa
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Yoshinori Sawae
- Machine Elements and Design Laboratory, Department of Mechanical Engineering, Kyushu University
| | - Kiyoshi Koyano
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| |
Collapse
|
12
|
Scherrer D, Bragger U, Ferrari M, Mocker A, Joda T. In-vitro polishing of CAD/CAM ceramic restorations: An evaluation with SEM and confocal profilometry. J Mech Behav Biomed Mater 2020; 107:103761. [PMID: 32276187 DOI: 10.1016/j.jmbbm.2020.103761] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2019] [Revised: 03/26/2020] [Accepted: 03/30/2020] [Indexed: 11/29/2022]
Abstract
AIM The objective of this In-vitro investigation was to analyze and compare the surface after polishing of 63 all-ceramic restorations fabricated out of monolithic zirconium dioxide (ZIR), lithium disilicate (LS) or feldspathic ceramic (FC) under standardized laboratory conditions with different protocols. The primary outcome was defined as the roughness (Ra/Sa) of different ceramic surfaces after distinctive polishing procedures. MATERIAL AND METHODS The study set-up consisted of three main groups: ZIR, LS, FC (20 crowns each), every group divided into two sub-groups (10 crowns each) depending on the polishing method. The untouched glazed surface of one crown per material served as a control. Every crown displayed a defined supra-contact at the palatal cusp which was removed with a fine grain (38-45 μm) diamond bur. Surface polishing was carried out with either a two-step system (one kit for zirconium dioxide (ZIR2), another kit for lithium disilicate (LS2) and feldspatic ceramic (FC2)), or a three-step system (ZIR3, LS3, FC3) under standardized conditions. Roughness parameters (Ra and Sa) were measured by means of confocal profilometry. Specimens were also visually inspected with scanning electron microscopy (SEM). Statistical analyses were performed using SPSS Statistics software. RESULTS Visual examination of the specimens using SEM showed several inhomogeneities on the glazed surface of the control samples, i.e. pores and particles. On every test sample, the grinding curves of the diamond bur were still recognizable. Polishing revealed similar median Ra 0.491 μm (ZIR2) and 0.434 μm (LS2) after two-step polishing (p = 0.754), and 0.311 μm (ZIR3) and 0.208 μm (LS3) after three-step polishing (p = 0.917). Surface roughness in group FC measured 0.889 μm (FC2) after the two-step polishing process and 0.903 μm (FC3) following three-step surface refinement. No significant difference was detectable between surface roughness of glazed controls compared to either polished surfaces with two-step or three-step treatment within one material. ZIR and LS presented significantly lower median roughness Ra after two-step and three-step procedures than test samples of FC, measured subsequent to either of the polishing methods (p = 0.016, p = 0.009). CONCLUSION The surface roughness of ZIR, LS and FC crowns after the use of chairside polishing kits was comparable with the roughness measured before occlusal adjustment. A two-step procedure showed as good results as a three-step process. A smoother surface was obtained for ZIR and LS compared to FC with both polishing protocols.
Collapse
Affiliation(s)
- Daniela Scherrer
- Department of Reconstructive Dentistry & Gerodontology, School of Dental Medicine, University of Bern, Switzerland.
| | - Urs Bragger
- Department of Reconstructive Dentistry & Gerodontology, School of Dental Medicine, University of Bern, Switzerland
| | - Marco Ferrari
- Department of Prosthodontics & Dental Materials, Department of Prosthodontics & Dental Materials, School of Dental Medicine, University of Siena, Italy; Department of Restorative Dentistry, School of Dental Medicine, University of Leeds, United Kingdom
| | - André Mocker
- Institute for Micro- and Nanotechnology MNT, NTB University of Applied Sciences Buchs, Switzerland
| | - Tim Joda
- Department of Reconstructive Dentistry, University Center for Dental Medicine Basel, University of Basel, Switzerland
| |
Collapse
|
13
|
Abstract
This article describes and illustrates the current state of chairside computer-aided design computer-aided manufacturing technologies and materials. It provides a historical background and discusses the different components of the chairside digital workflow: intraoral scanners, design software, milling machines, and sinter furnaces. The material range available for chairside digital dentistry is broad and includes polymethyl methacrylates, composite resins, and a large variety of ceramics. Clinical applications and success rates of the different material groups are summarized and discussed based on the current scientific evidence.
Collapse
Affiliation(s)
- Markus B Blatz
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, 240 South 40th Street, Philadelphia, PA 19104, USA.
| | - Julian Conejo
- Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, 240 South 40th Street, Philadelphia, PA 19104, USA
| |
Collapse
|
14
|
Saha MK, Bansal S, Pathak V, Bhardwaj S, Chauhan A, Nirwan AS. A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study. Med Pharm Rep 2019; 92:172-177. [PMID: 31086846 PMCID: PMC6510367 DOI: 10.15386/mpr-985] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Revised: 04/11/2018] [Accepted: 04/25/2018] [Indexed: 11/23/2022] Open
Abstract
Introduction The use of zirconia based all-ceramic restorations are preferred nowadays owing to superior biologic and esthetic properties. However, these restorations have also reported higher incidences of fracture and chipping. The clinical success may be enhanced by optimizing the core design, through the introduction of monolithic zirconia, or the layered crowns can be strengthened by adding the cervical collar to them. Objective This study was performed with the objective to compare and evaluate the fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar. Methods A prospective observational study was carried out to compare 45 fabricated zirconia crowns of three different designs on a customized metal mould. The samples were oriented on the metal mould and subjected to confocal microscope for the evaluation of marginal integrity followed by cementing the crown on the metal mould and subjecting it to the universal testing machine for the analysis for the flexural strength. Data were analyzed using one way Anova and t- test for inter and intra groups. The significance level was set at P ≤ 0.05. Results The monolith zirconia crowns and layered zirconia crowns with cervical collar reported more flexural strength. Conclusion The amount of force required to fracture the zirconia crowns was higher in the case of monolith zirconia crown and layered zirconia crown with cervical collar as compared to the layered zirconia crown without cervical collar.
Collapse
Affiliation(s)
- Mainak Kanti Saha
- Department of Prosthodontics, Rau College of Dental Sciences, Indore, India
| | - Surbhi Bansal
- Department of Prosthodontics, Rau College of Dental Sciences, Indore, India
| | - Vandana Pathak
- Department of Prosthodontics, Rau College of Dental Sciences, Indore, India
| | - Shivani Bhardwaj
- Department of Prosthodontics, Rau College of Dental Sciences, Indore, India
| | - Astha Chauhan
- Department of Public Health Dentistry, Index Institute of Dental Sciences, Indore, India
| | - Amit Singh Nirwan
- Department of Oral Surgery, Rau College of Dental Sciences, Indore, India
| |
Collapse
|
15
|
Maroulakos G, Thompson GA, Kontogiorgos ED. Effect of cement type on the clinical performance and complications of zirconia and lithium disilicate tooth-supported crowns: A systematic review. Report of the Committee on Research in Fixed Prosthodontics of the American Academy of Fixed Prosthodontics. J Prosthet Dent 2019; 121:754-765. [DOI: 10.1016/j.prosdent.2018.10.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 10/17/2018] [Accepted: 10/22/2018] [Indexed: 12/28/2022]
|
16
|
Cantner F, Cacaci C, Mücke T, Randelzhofer P, Hajtó J, Beuer F. Clinical performance of tooth- or implant-supported veneered zirconia single crowns: 42-month results. Clin Oral Investig 2019; 23:4301-4309. [PMID: 30887188 DOI: 10.1007/s00784-019-02878-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 03/11/2019] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The objective of this clinical study was to compare and assess the clinical performance of tooth-supported and implant-supported zirconia single crowns with sintered veneering caps. METHODS In this prospective study, 118 patients with a total of 220 single crowns placed on 106 teeth (69 vital teeth, 37 endodontically treated teeth) and 114 implants in molar and premolar regions were examined during a mean observation period of 42 months. The restorations were evaluated for technical failures such as veneering porcelain fractures (chipping), surface quality, marginal fit, and the interface quality of the coping and sintered veneering. The soft tissue status was assessed using the modified Silness and Löe's plaque and gingival index (mPI) and the modified Muhlemann sulcus bleeding index (mSBI). Tooth-supported crowns were checked for secondary caries and hypersensitivity during the follow-up period. Recalls were performed every 6 months. RESULTS The 3-year Kaplan-Meier success probability was 98.2% and 100% for implant- and tooth-supported crowns, respectively. A significant difference could be detected between the implant-supported and tooth-supported zirconia single crowns, in terms of their chipping rate (p = 0.039). Veneering material fractures were recorded on two implant-supported restorations (1.8%). No veneering fractures occurred on tooth-supported single crowns. The plaque and gingival index and sulcus bleeding index showed stable and healthy soft peri-implant and periodontal tissues. Neither loss of vitality nor secondary caries occurred on tooth-supported crowns. CONCLUSIONS Zirconia-based single crowns with a sintered veneering cap showed promising clinical results on both tooth and implant abutments; however, the dental implants were more prone to complications. In terms of clinical significance, high-strength ceramic with a sintered veneering cap can be recommended for prosthetic treatment of both tooth- and implant-supported single crowns in molar regions. CLINICAL RELEVANCE This study provides valuable information for further application of all-ceramic restorations.
Collapse
Affiliation(s)
| | - Claudio Cacaci
- Private Dental Office, Weinstraße 4, 80333, Munich, Germany
| | - Thomas Mücke
- Department of Oral and Maxillofacial Surgery, St. Josefshospital, Kurfürstenstr. 69, 47829, Krefeld-Uerdingen, Germany
| | | | - Jan Hajtó
- Private Dental Office, Briennerstrße 7, 80333, Munich, Germany
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, University Charité Berlin, Assmannshauser Strasse 4-6, 14197, Berlin, Germany.
| |
Collapse
|
17
|
Miura S, Kasahara S, Yamauchi S, Katsuda Y, Harada A, Aida J, Egusa H. A possible risk of CAD/CAM-produced composite resin premolar crowns on a removable partial denture abutment tooth: a 3-year retrospective cohort study. J Prosthodont Res 2018; 63:78-84. [PMID: 30584052 DOI: 10.1016/j.jpor.2018.08.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 08/15/2018] [Accepted: 08/21/2018] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the early performance of computer-aided design/computer-aided manufacturing (CAD/CAM)-produced composite resin crown (CAD/CAM composite crown) treatment on premolars, specifically, placement on a removable partial denture (RPD) abutment tooth, and the distalmost tooth in the dental arch, as possible clinical risk factors. METHODS A retrospective cohort study (April 2014 to July 2017) was performed utilizing the clinical records of patients who received a premolar CAD/CAM composite crown treatment. The variables of time of treatment for (1) successful crowns (complication event-free) and (2) surviving crowns (clinically functional including re-luted) were estimated using Kaplan-Meier analysis. Survival distributions regarding "RPD abutment tooth" and "distalmost tooth" were analyzed with the log-rank test. Multilevel survival analyses were used to identify hazard ratios and associated risk factors. RESULTS Five hundred and forty-seven crowns were evaluated (mean follow-up time 1.3±0.9years) in 327 patients. A total of 87 crowns had at least one complication, with loss of crown retention being the most common (70 crowns). Estimated success and survival rates at 3 years were 71.7% and 96.4%, respectively. The risk of complications was significantly higher for an RPD abutment tooth than for a non-RPD abutment tooth. There was no significant difference between the distalmost tooth and non-distalmost tooth in the dental arch. CONCLUSIONS The demonstrated complication rate for CAD/CAM composite crowns placed on premolars was 15.9% over a period of up to 3 years. There was a substantial risk of complications with placement of such a crown on an RPD abutment tooth.
Collapse
Affiliation(s)
- Shoko Miura
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan; Liaison Center for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan; Division of Fixed Prosthodontics, Meikai University School of Dentistry, Sakado, Japan.
| | - Shin Kasahara
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Shinobu Yamauchi
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan; Dr. Anthony Volpe Research Center, ADA Foundation, Gaithersburg, MD, USA
| | - Yusuke Katsuda
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Akio Harada
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Jun Aida
- Department of International and Community Oral Health, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Hiroshi Egusa
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Japan; Liaison Center for Innovative Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan.
| |
Collapse
|
18
|
McCracken MS, Litaker MS, Gordan VV, Karr T, Sowell E, Gilbert GH. Remake Rates for Single-Unit Crowns in Clinical Practice: Findings from The National Dental Practice-Based Research Network. J Prosthodont 2018; 28:122-130. [PMID: 30412320 DOI: 10.1111/jopr.12995] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/10/2018] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Some crowns returned from the laboratory are clinically unacceptable, and dentists must remake them. The objectives of this study were to: (1) quantify the remake rate of single-unit crowns; and (2) identify factors significantly associated with crown remakes and intraoral fit. MATERIALS AND METHODS Dentists participating in the National Dental Practice-Based Research Network recruited patients needing crowns and documented fabrication techniques, patient characteristics, and outcomes. Crowns were considered clinically acceptable or rejected. Also, various aspects of the clinical fit of the crown were graded and categorized as 'Goodness of Fit (GOF).' Dentist and patient characteristics were tested statistically for associations with crown acceptability and GOF. RESULTS More than 200 dentists participated in this study (N = 205) and evaluated 3750 single-unit crowns. The mean age (years) of patients receiving a crown was 55. The remake rate for crowns was 3.8%. The range of rejection rates among individual practitioners was 0% to 42%. Most clinicians (118, or 58%) did not reject any crowns; all rejections came from 42% of the clinicians (n = 87). The most common reasons for rejections were proximal misfit, marginal errors, and esthetic failures. Fewer years in practice was significantly associated with lower crown success rates and lower fit scores. GOF was also associated with practice busyness and patient insurance status, patient gender (dentists reported better fit for female patients), and patient ethnicity. CONCLUSIONS The crown remake rate in this study was about 4%. Remakes and crown GOF were associated with certain dentist and practice characteristics.
Collapse
Affiliation(s)
- Michael S McCracken
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Mark S Litaker
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Valeria V Gordan
- Restorative Dental Sciences Department, Operative Dentistry Division, College of Dentistry, University of Florida, Gainesville, FL
| | | | - Ellen Sowell
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | - Gregg H Gilbert
- Department of Clinical and Community Sciences, School of Dentistry, University of Alabama at Birmingham, Birmingham, AL
| | | |
Collapse
|
19
|
Olley RC, Andiappan M, Frost PM. An up to 50-year follow-up of crown and veneer survival in a dental practice. J Prosthet Dent 2018; 119:935-941. [DOI: 10.1016/j.prosdent.2017.06.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Revised: 06/19/2017] [Accepted: 06/20/2017] [Indexed: 10/18/2022]
|
20
|
Tabatabaian F. Color Aspect of Monolithic Zirconia Restorations: A Review of the Literature. J Prosthodont 2018; 28:276-287. [DOI: 10.1111/jopr.12906] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/24/2018] [Indexed: 02/02/2023] Open
Affiliation(s)
- Farhad Tabatabaian
- Department of Prosthodontics, School of Dentistry; Shahid Beheshti University of Medical Sciences; Tehran Iran
| |
Collapse
|
21
|
Miura S, Kasahara S, Yamauchi S, Egusa H. Effect of finish line design on stress distribution in bilayer and monolithic zirconia crowns: a three-dimensional finite element analysis study. Eur J Oral Sci 2018; 126:159-165. [DOI: 10.1111/eos.12402] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Shoko Miura
- Division of Molecular and Regenerative Prosthodontics; Tohoku University Graduate School of Dentistry; Sendai Miyagi Japan
| | - Shin Kasahara
- Division of Molecular and Regenerative Prosthodontics; Tohoku University Graduate School of Dentistry; Sendai Miyagi Japan
| | - Shinobu Yamauchi
- Division of Molecular and Regenerative Prosthodontics; Tohoku University Graduate School of Dentistry; Sendai Miyagi Japan
| | - Hiroshi Egusa
- Division of Molecular and Regenerative Prosthodontics; Tohoku University Graduate School of Dentistry; Sendai Miyagi Japan
| |
Collapse
|
22
|
Tabatabaian F. Color in Zirconia-Based Restorations and Related Factors: A Literature Review. J Prosthodont 2018; 27:201-211. [DOI: 10.1111/jopr.12740] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/16/2017] [Indexed: 11/30/2022] Open
Affiliation(s)
- Farhad Tabatabaian
- Department of Prosthodontics, School of Dentistry; Shahid Beheshti University of Medical Sciences; Tehran Iran
| |
Collapse
|
23
|
Gunge H, Ogino Y, Kihara M, Tsukiyama Y, Koyano K. Retrospective clinical evaluation of posterior monolithic zirconia restorations after 1 to 3.5 years of clinical service. J Oral Sci 2018; 60:154-158. [DOI: 10.2334/josnusd.17-0176] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Hiroto Gunge
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Yoichiro Ogino
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Masafumi Kihara
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| | - Yoshihiro Tsukiyama
- Section of Dental Education, Division of Oral Biological Sciences, Faculty of Dental Science, Kyushu University
| | - Kiyoshi Koyano
- Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University
| |
Collapse
|
24
|
Faus-Matoses V, Faus-Matoses I, Ruiz-Bell E, Faus-Llácer VJ. Severe tetracycline dental discoloration: Restoration with conventional feldspathic ceramic veneers. A clinical report. J Clin Exp Dent 2017; 9:e1379-e1382. [PMID: 29302294 PMCID: PMC5741855 DOI: 10.4317/jced.54359] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 10/23/2017] [Indexed: 11/29/2022] Open
Abstract
The treatment of severe tetracycline discoloration is a challenge for the dentist. There are several treatment options and one of the most effective is the use of feldspathic veneers. The aim of this clinical case was to carry out the replacement with conventional feldspathic ceramic veneers on a patient with highly stained teeth (grade IV tetracycline) by a minimally invasive approach. Clinical examination revealed gingival retraction, color change of the veneers, ceramic cracked of 1.1 and 1.3 and incisal wear in lower anterior teeth. The decision was to retreat with feldspathic ceramic veneers from 1.6 to 2.6. Premolars and first molars were included because its dark color intensifies the width buccal corridors. Also, the restoration with veneers from 3.3 to 4.3 was considered. Firstly, the veneers were removed and the color was selected by the Vitapan 3D Master guide (Vita Zahnfabrick, Bad Säckingen, Germany). Mock-up was made to evaluate aesthetic, phonetic and functional parameters. Then, teeth were prepared through the mock-up in order to reduce the minimal amount of dental tissue possible. Opaque dentine mass of microhybrid composite (Esthet-X A2O, Dentsply Sirona, Konstanz, Germany) was placed to mask the most intense stains. The definitive impressions were taken with silicone (Aquasil Ultra XLV, Dentsply Sirona, Konstanz, Germany) were taken to fabricate conventional feldsphatic ceramic veneers (Noritake kisai Co, Ltd. Japan) by the parallel stratification masking technique. For cementing, an opaque cement was selected from the try-in tests (Calibra, Dentsply Sirona, Konstanz, Germany) and the composite was silicatized with an air-abrasion device. A favorable and minimally invasive result was achieved to treat grade IV tetracycline stains, surpassing the patient’s aesthetic expectations and functional needs.
Key words:Porcelain veneer, tetracycline teeth, minimally invasive, masking, opaque composite.
Collapse
Affiliation(s)
- Vicente Faus-Matoses
- DDS, MSc, PhD. Co-director of the Master of Restorative Dentistry and Endodontics, Department of Stomatology, Medicine and Dental School, Valencia University, Spain
| | - Ignacio Faus-Matoses
- DDS, MSc, PhD. Professor of the Master in Orthodontics, Department of Stomatology, Medicine and Dental School, Valencia University, Spain
| | | | - Vicente J Faus-Llácer
- MD, DDS, PhD. Director of the Master of Restorative Dentistry and Endodontics, Department of Stomatology, Medicine and Dental School, Valencia University, Spain
| |
Collapse
|
25
|
Blatz MB, Vonderheide M, Conejo J. The Effect of Resin Bonding on Long-Term Success of High-Strength Ceramics. J Dent Res 2017; 97:132-139. [PMID: 28876966 DOI: 10.1177/0022034517729134] [Citation(s) in RCA: 147] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Digital manufacturing, all-ceramics, and adhesive dentistry are currently the trendiest topics in clinical restorative dentistry. Tooth- and implant-supported fixed restorations from computer-aided design (CAD)/computer-aided manufacturing (CAM)-fabricated high-strength ceramics-namely, alumina and zirconia-are widely accepted as reliable alternatives to traditional metal-ceramic restorations. Most recent developments have focused on high-translucent monolithic full-contour zirconia restorations, which have become extremely popular in a short period of time, due to physical strength, CAD/CAM fabrication, and low cost. However, questions about proper resin bonding protocols have emerged, as they are critical for clinical success of brittle ceramics and treatment options that rely on adhesive bonds, specifically resin-bonded fixed dental prostheses or partial-coverage restorations such as inlays/onlays and veneers. Resin bonding has long been the gold standard for retention and reinforcement of low- to medium-strength silica-based ceramics but requires multiple pretreatment steps of the bonding surfaces, increasing complexity, and technique sensitivity compared to conventional cementation. Here, we critically review and discuss the evidence on resin bonding related to long-term clinical outcomes of tooth- and implant-supported high-strength ceramic restorations. Based on a targeted literature search, clinical long-term studies indicate that porcelain-veneered alumina or zirconia full-coverage crowns and fixed dental prostheses have high long-term survival rates when inserted with conventional cements. However, most of the selected studies recommend resin bonding and suggest even greater success with composite resins or self-adhesive resin cements, especially for implant-supported restorations. High-strength ceramic resin-bonded fixed dental prostheses have high long-term clinical success rates, especially when designed as a cantilever with only 1 retainer. Proper pretreatment of the bonding surfaces and application of primers or composite resins that contain special adhesive monomers are necessary. To date, there are no clinical long-term data on resin bonding of partial-coverage high-strength ceramic or monolithic zirconia restorations.
Collapse
Affiliation(s)
- M B Blatz
- 1 Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA
| | - M Vonderheide
- 1 Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA
| | - J Conejo
- 1 Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
26
|
Choi JW, Kim SY, Bae JH, Bae EB, Huh JB. In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses. J Adv Prosthodont 2017; 9:244-251. [PMID: 28874990 PMCID: PMC5582089 DOI: 10.4047/jap.2017.9.4.244] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 02/17/2017] [Accepted: 03/15/2017] [Indexed: 11/25/2022] Open
Abstract
PURPOSE The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.
Collapse
Affiliation(s)
- Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Yeun Kim
- Department of Prosthodontics, Pusan National University Hospital, Pusan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
27
|
Nakonieczny DS, Ziębowicz A, Paszenda ZK, Krawczyk C. Trends and perspectives in modification of zirconium oxide for a dental prosthetic applications – A review. Biocybern Biomed Eng 2017. [DOI: 10.1016/j.bbe.2016.10.005] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
28
|
Schwindling FS, Stober T. A comparison of two digital techniques for the fabrication of complete removable dental prostheses: A pilot clinical study. J Prosthet Dent 2016; 116:756-763. [DOI: 10.1016/j.prosdent.2016.03.022] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Revised: 03/23/2016] [Accepted: 03/23/2016] [Indexed: 11/30/2022]
|
29
|
Dogan S, Raigrodski AJ, Zhang H, Mancl LA. Prospective cohort clinical study assessing the 5-year survival and success of anterior maxillary zirconia-based crowns with customized zirconia copings. J Prosthet Dent 2016; 117:226-232. [PMID: 27765396 DOI: 10.1016/j.prosdent.2016.07.019] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 07/02/2016] [Accepted: 07/05/2016] [Indexed: 10/20/2022]
Abstract
STATEMENT OF PROBLEM Studies evaluating anterior zirconia-based crowns are limited. PURPOSE The purpose of this prospective cohort clinical study was to assess the efficacy of zirconia-based anterior maxillary crowns with 0.3-mm customized copings at the cervical third and anatomical design elsewhere for up to 5 years of service. MATERIAL AND METHODS Eighteen participants who required an anterior maxillary crown (n=20) and who had signed a consent form approved by the University of Washington Health Sciences Center Human Subjects Division were enrolled. All preparations were standardized and prepared with an occlusal reduction of 1.5 to 2 mm and an axial reduction of 1 to 1.5 mm with 10 degrees of convergence angle. All finish lines were located on the sound tooth structure. Zirconia copings (Lava; 3M ESPE) were custom designed and milled to a 0.3-mm thickness at the cervical third and with selective thickness elsewhere to support the veneering porcelain. All restorations were luted with self-etching self-adhesive composite resin cement. Recall appointments were at 2 weeks, 6 months, and 12 months, and annually thereafter for 5 years. Modified Ryge criteria were used to assess the clinical fracture measurements, esthetics, marginal discoloration, marginal adaptation, radiographic proximal recurrent caries, and periapical pathoses. Descriptive statistics and 95% confidence intervals were used to describe the number and rate of complications and self-reported satisfaction with the crowns. RESULTS Twenty crowns with a mean follow-up of 58.7 months were evaluated. All crowns were rated as Alfa for fracture measurements (smooth surface, no fracture/chipping). Twelve crowns were rated esthetically as Romeo (no mismatch in color and shade) and 8 as Sierra (mismatch in color and shade within normal range). Twelve crowns were rated as Alfa (no visible evidence of crevice) and 8 as Bravo (visible evidence of crevice, no penetration of explorer) for marginal integrity. Nineteen were rated as Alfa (no discoloration) and 1 as Bravo (superficial discoloration) for marginal discoloration. No proximal caries or periapical pathoses were detected in 5 years. Participants were highly satisfied with their crowns after 5 years (mean ±SD: 9.8 ±0.4 on 0 to 10 scale). CONCLUSIONS Zirconia-based anterior maxillary crowns with customized copings with 0.3-mm thickness at the cervical third and zirconia margins performed well after 5 years of service.
Collapse
Affiliation(s)
- Sami Dogan
- Assistant Professor, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.
| | - Ariel J Raigrodski
- Professor, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash
| | - Hai Zhang
- Associate Professor, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash
| | - Lloyd A Mancl
- Research Associate Professor, Department of Dental Public Health Sciences, University of Washington, Seattle, Wash
| |
Collapse
|
30
|
Afrashtehfar KI, Emami E, Ahmadi M, Eilayyan O, Abi-Nader S, Tamimi F. Failure rate of single-unit restorations on posterior vital teeth: A systematic review. J Prosthet Dent 2016; 117:345-353.e8. [PMID: 27765400 DOI: 10.1016/j.prosdent.2016.08.003] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 08/03/2016] [Accepted: 08/04/2016] [Indexed: 11/26/2022]
Abstract
STATEMENT OF PROBLEM No knowledge synthesis exists concerning when to use a direct restoration versus a complete-coverage indirect restoration in posterior vital teeth. PURPOSE The purpose of this systematic review was to identify the failure rate of conventional single-unit tooth-supported restorations in posterior permanent vital teeth as a function of remaining tooth structure. MATERIAL AND METHODS Four databases were searched electronically, and 8 selected journals were searched manually up to February 2015. Clinical studies of tooth-supported single-unit restorative treatments with a mean follow-up period of at least 3 years were selected. The outcome measured was the restorations' clinical or radiological failure. Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines, the Cochrane Collaboration procedures for randomized control trials, the Strengthening the Reporting of Observational Studies in Epidemiology criteria for observational studies, 2 reviewers independently applied eligibility criteria, extracted data, and assessed the quality of the evidence of the included studies using the American Association of Critical Care Nurses' system. The weighted-mean group 5-year failure rates of the restorations were reported according to the type of treatment and remaining tooth structure. A metaregression model was used to assess the correlation between the number of remaining tooth walls and the weighted-mean 5-year failure rates. RESULTS Five randomized controlled trials and 9 observational studies were included and their quality ranged from low to moderate. These studies included a total of 358 crowns, 4804 composite resins, and 303582 amalgams. Data obtained from the randomized controlled trials showed that, regardless of the amount of remaining tooth structure, amalgams presented better outcomes than composite resins. Furthermore, in teeth with fewer than 2 remaining walls, high-quality observational studies demonstrated that crowns were better than amalgams. A clear inverse correlation was found between the amount of remaining tooth structure and restoration failure. CONCLUSIONS Insufficient high-quality data are available to support one restorative treatment or material over another for the restoration of vital posterior teeth. However, the current evidence suggests that the failure rates of treatments may depend on the amount of remaining tooth structure and types of treatment.
Collapse
Affiliation(s)
- Kelvin I Afrashtehfar
- Teaching and Research Assistant, Division of Prosthodontics and Restorative Dentistry, Faculty of Dentistry, McGill University, Montreal, Quebec, Canada; Research Associate, Division of Oral Health and Society, McGill University, Montreal, Quebec, Canada; and Visiting Scholar, Department of Reconstructive Dentistry, School of Dental Medicine, University of Bern, Berne, Switzerland
| | - Elham Emami
- Associate Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Montreal, Montreal, Quebec, Canada
| | - Motahareh Ahmadi
- Research Assistant, Oral Health and Rehabilitation Research Unit, Faculty of Dentistry, University of Montreal, Montreal, Quebec, Canada
| | - Owis Eilayyan
- Teaching and Research Assistant, Faculty of Medicine, McGill University, Montreal, Quebec, Canada
| | - Samer Abi-Nader
- Division Director and Associate Professor, Division of Prosthodontics and Restorative Dentistry, Faculty of Dentistry, McGill University, Montreal, Quebec, Canada
| | - Faleh Tamimi
- Associate Professor, Division of Prosthodontics and Restorative Dentistry, Faculty of Dentistry, McGill University, Montreal, Quebec, Canada.
| |
Collapse
|
31
|
Bömicke W, Rammelsberg P, Stober T, Schmitter M. Short-Term Prospective Clinical Evaluation of Monolithic and Partially Veneered Zirconia Single Crowns. J ESTHET RESTOR DENT 2016; 29:22-30. [DOI: 10.1111/jerd.12270] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Wolfgang Bömicke
- Dr. med. Dent, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Heidelberg Germany
| | - Peter Rammelsberg
- Prof. Dr. med. Dent, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Heidelberg Germany
| | - Thomas Stober
- Prof. Dr. med. Dent, Department of Prosthodontics; Heidelberg University Hospital, University of Heidelberg; Heidelberg Germany
| | - Marc Schmitter
- Prof. Dr. med. Dent, Department of Prosthodontics; Würzburg University Hospital, University of Würzburg; Würzburg Germany
| |
Collapse
|
32
|
Schmitz JH, Beani M. Effect of different cement types on monolithic lithium disilicate complete crowns with feather-edge preparation design in the posterior region. J Prosthet Dent 2016; 115:678-83. [DOI: 10.1016/j.prosdent.2015.10.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2015] [Revised: 10/12/2015] [Accepted: 10/15/2015] [Indexed: 10/22/2022]
|
33
|
Øilo M, Kvam K, Gjerdet NR. Load at fracture of monolithic and bilayered zirconia crowns with and without a cervical zirconia collar. J Prosthet Dent 2016; 115:630-6. [DOI: 10.1016/j.prosdent.2015.11.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Revised: 11/02/2015] [Accepted: 11/05/2015] [Indexed: 11/26/2022]
|
34
|
Abstract
Ceramics has become increasingly popular as a dental restorative material because of its superior esthetics, as well as its inertness and biocompatibility. Among dental ceramics, zirconia is used as a dental biomaterial and it is the material of choice in contemporary restorative dentistry. Zirconia ceramics has both clinical popularity and success due to its outstanding mechanical properties and ease of machining in the green stage via computer-aided design and computer-aided manufacturing technology. Zirconia is one of the most promising restorative biomaterial because it has favorable mechanical and chemical properties suitable for medical application. Zirconia ceramics is becoming a prevalent biomaterial in dentistry. Clinical evaluations also indicate a good success rate for zirconia with minimal complications. This article reviews the current literature on dental zirconia with respect to basic properties, biocompatibility, and clinical applications in aesthetic dentistry as single unit crown.
Collapse
Affiliation(s)
- Yasser Alfawaz
- Lecturer, Department of Restorative Dental Sciences, College of Dentistry King Saud University, Riyadh, Kingdom of Saudi Arabia, Phone: +96614677420, e-mail:
| |
Collapse
|
35
|
Tsirogiannis P, Reissmann DR, Heydecke G. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: A systematic review and meta-analysis. J Prosthet Dent 2016; 116:328-335.e2. [PMID: 27061627 DOI: 10.1016/j.prosdent.2016.01.028] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 01/27/2016] [Accepted: 01/28/2016] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM In existing published reports, some studies indicate the superiority of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides the lowest mean values for marginal adaptation is inconclusive. The findings from those studies cannot be easily generalized, and in vivo studies that could provide valid and meaningful information are limited in the existing publications. PURPOSE The purpose of this study was to systematically review existing reports and evaluate the marginal fit of ceramic single-tooth restorations after either digital or conventional impression methods by combining the available evidence in a meta-analysis. MATERIAL AND METHODS The search strategy for this systematic review of the publications was based on a Population, Intervention, Comparison, and Outcome (PICO) framework. For the statistical analysis, the mean marginal fit values of each study were extracted and categorized according to the impression method to calculate the mean value, together with the 95% confidence intervals (CI) of each category, and to evaluate the impact of each impression method on the marginal adaptation by comparing digital and conventional techniques separately for in vitro and in vivo studies. RESULTS Twelve studies were included in the meta-analysis from the 63 identified records after database searching. For the in vitro studies, where ceramic restorations were fabricated after conventional impressions, the mean value of the marginal fit was 58.9 μm (95% CI: 41.1-76.7 μm), whereas after digital impressions, it was 63.3 μm (95% CI: 50.5-76.0 μm). In the in vivo studies, the mean marginal discrepancy of the restorations after digital impressions was 56.1 μm (95% CI: 46.3-65.8 μm), whereas after conventional impressions, it was 79.2 μm (95% CI: 59.6-98.9 μm) CONCLUSION No significant difference was observed regarding the marginal discrepancy of single-unit ceramic restorations fabricated after digital or conventional impressions.
Collapse
Affiliation(s)
- Panagiotis Tsirogiannis
- Postgraduate student, Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Daniel R Reissmann
- Associate Professor, Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Guido Heydecke
- Professor, Department of Prosthetic Dentistry, Center for Dental and Oral Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
36
|
Dhima M. A Contemporary Framework and Suprastructure Ceramic Design for Posterior Implant Fixed Partial Denture. J Prosthodont 2016; 27:193-196. [PMID: 26999471 DOI: 10.1111/jopr.12474] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/23/2016] [Indexed: 11/28/2022] Open
Abstract
Bone and soft tissue deformities in long-standing partial edentulism are commonly treated with implant therapy. The various ceramic restorative systems available and digital technology allow for customization of design and material selection. A substructure design that mimics tooth preparation in a custom zirconia framework with a lithium disilicate suprastructure is presented as an effort to address the functional and esthetic challenges posed by long-standing posterior partial edentulism. The aim is to present several contemporary elements of design to address the functional, esthetic, and maintenance needs.
Collapse
Affiliation(s)
- Matilda Dhima
- Department of Prosthodontics, School of Dental Medicine, University of Pittsburgh, Pittsburgh, PA
| |
Collapse
|
37
|
Rinke S, Kramer K, Bürgers R, Roediger M. A practice-based clinical evaluation of the survival and success of metal-ceramic and zirconia molar crowns: 5-year results. J Oral Rehabil 2015; 43:136-44. [DOI: 10.1111/joor.12348] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/24/2015] [Indexed: 12/22/2022]
Affiliation(s)
- S. Rinke
- Private Practice; Hanau Germany
- Department of Prosthodontics; Georg-August-University; Göttingen Germany
| | - K. Kramer
- Department of Medical Statistics; Georg-August-University; Göttingen Germany
| | - R. Bürgers
- Department of Prosthodontics; Georg-August-University; Göttingen Germany
| | - M. Roediger
- Department of Prosthodontics; Georg-August-University; Göttingen Germany
| |
Collapse
|
38
|
Bonfante EA, Suzuki M, Lorenzoni FC, Sena LA, Hirata R, Bonfante G, Coelho PG. Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns. Dent Mater 2015; 31:e168-77. [DOI: 10.1016/j.dental.2015.05.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2014] [Revised: 03/28/2015] [Accepted: 05/15/2015] [Indexed: 01/22/2023]
|
39
|
Seydler B, Schmitter M. Clinical performance of two different CAD/CAM-fabricated ceramic crowns: 2-Year results. J Prosthet Dent 2015; 114:212-6. [DOI: 10.1016/j.prosdent.2015.02.016] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Revised: 02/17/2015] [Accepted: 02/17/2015] [Indexed: 11/24/2022]
|
40
|
Larsson C, Drazic M, Nilsson E, Vult von Steyern P. Fracture of porcelain-veneered gold-alloy and zirconia molar crowns using a modified test set-up. ACTA BIOMATERIALIA ODONTOLOGICA SCANDINAVICA 2015. [PMID: 28642899 PMCID: PMC5433234 DOI: 10.3109/23337931.2015.1057825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Objective: The main aim of this study was to compare fracture load and fracture mode of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and metal-ceramic (MC) molar crowns using a modified test set-up to produce fractures similar to those seen in vivo, i.e. fractures of the veneering material rather than complete fractures. Materials and methods: 13 high-noble-alloy MC and 13 Y-TZP molar crowns veneered with porcelain were manufactured. The crowns were artificially aged before final load to fracture. Load was applied using a 7 mm diameter steel ball exerting force on the cusps with stresses directed toward the core-veneer interface. Fracture surface analysis was performed using light- and scanning electron microscopy. Results: The test design produced fractures of the veneering material rather than complete fractures. MC crowns withstood significantly (p > 0.001) higher loads (mean 2155 N) than Y-TZP (mean 1505 N) crowns, yet both endure loads sufficient for predictable clinical use. Fracture mode differed between MC and Y-TZP. MC crowns exhibited fractures involving the core-veneer interface but without core exposure. One Y-TZP crown suffered a complete fracture, all others except one displayed fractures of the veneering material involving the core-veneer interface with core exposure. Conclusions: The test set-up produces fractures similar to those found in vivo and may be useful to evaluate the core-veneer interface of different material systems, both metals and ceramics. The study confirms suggestions from previous studies of a weaker core-veneer bond for Y-TZP compared to MC crowns.
Collapse
Affiliation(s)
- Christel Larsson
- Department of Materials Science and Technology, Faculty of Odontology, Malmö UniversityMalmöSweden
| | - Marko Drazic
- Department of Materials Science and Technology, Faculty of Odontology, Malmö UniversityMalmöSweden
| | - Eddie Nilsson
- Department of Materials Science and Technology, Faculty of Odontology, Malmö UniversityMalmöSweden
| | - Per Vult von Steyern
- Department of Materials Science and Technology, Faculty of Odontology, Malmö UniversityMalmöSweden
| |
Collapse
|
41
|
Clinical outcomes of zirconia-based implant- and tooth-supported single crowns. Clin Oral Investig 2015; 20:169-78. [PMID: 25910472 DOI: 10.1007/s00784-015-1479-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 04/13/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES Zirconia-based restorations have been increasingly used on implant and teeth abutments, but the evidence about clinical outcomes of these restorations is limited. The aim of this study was to assess up to 7-year clinical outcomes of implant- and tooth-supported zirconia-based single crowns. MATERIALS AND METHODS In this retrospective study, 261 patients with 556 single crowns supported by either teeth (324) or implants (232) were examined during 3- to 7-year follow-up (mean observation of 60.70 months for tooth and 59.20 months for implant-supported crowns). California Dental Association (CDA) quality evaluation system was used to evaluate the restorations. Soft tissue status was assessed using plaque and gingival index scores, bleeding on probing, and pocket depth. Patient and professional satisfaction were evaluated by visual analog scale (VAS). RESULTS The 5-year Kaplan-Meier survival probability was 98.3 and 97.3 for implant- and tooth-supported crowns, respectively. In regard to CDA rating, most of the crowns were ranked as either excellent or acceptable (99.5 %). The recorded failures were replacement of the crown due to porcelain chipping (3), implant failure (1), and teeth extraction (5). Soft tissue parameters were not affected by the restorations compare to control teeth. The VAS was high for both patients and clinicians. CONCLUSIONS Zirconia-based single crowns on both tooth and implant abutments showed promising clinical performance in this up to 7-year follow-up. CLINICAL RELEVANCE The zirconia-based single crowns can be used clinically for tooth- and implant-supported restorations.
Collapse
|
42
|
Takeichi T, Miura S, Kasahara S, Egusa H, Hara M, Sato T, Yoshinari M, Odatsu T, Watanabe I, Sawase T. Update zirconia restorations. J Prosthodont Res 2015; 59:81-3. [PMID: 25487121 DOI: 10.1016/j.jpor.2014.11.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2014] [Accepted: 11/10/2014] [Indexed: 11/26/2022]
|
43
|
Rinke S, Lange K, Roediger M, Gersdorff N. Risk factors for technical and biological complications with zirconia single crowns. Clin Oral Investig 2015; 19:1999-2006. [DOI: 10.1007/s00784-015-1410-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Accepted: 01/21/2015] [Indexed: 11/30/2022]
|
44
|
Donovan TE, Marzola R, Becker W, Cagna DR, Eichmiller F, McKee JR, Metz JE, Albouy JP. Annual review of selected scientific literature: report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2014; 112:1038-87. [PMID: 25443419 DOI: 10.1016/j.prosdent.2014.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 09/02/2014] [Accepted: 09/02/2014] [Indexed: 12/14/2022]
Affiliation(s)
- Terence E Donovan
- Chair, Committee on Scientific Investigation, American Academy of Restorative Dentistry (AARD); Professor and Section Head for Biomaterials, Department of Operative Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC.
| | | | - William Becker
- Clinical Professor, Advanced Education in Prosthodontics, Herman Ostrow School of Dentistry, University of Southern California; private practice, Tucson, Ariz
| | - David R Cagna
- Associate Dean, Professor and Director, Advanced Prosthodontics, University of Tennessee, Health Science Center, College of Dentistry, Memphis, Tenn
| | | | | | | | | |
Collapse
|
45
|
Rechmann P, Buu NCH, Rechmann BMT, Finzen FC. Laser all-ceramic crown removal-a laboratory proof-of-principle study-phase 2 crown debonding time. Lasers Surg Med 2014; 46:636-43. [PMID: 25125242 DOI: 10.1002/lsm.22280] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/14/2014] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVES The removal of all-ceramic crowns is a time consuming procedure in the dental office. Little research has been done in alternative removal techniques for all-ceramic crowns. The objective of the second phase of this proof-of-principle laboratory pilot study was to evaluate whether Ivoclar Vivadent all-ceramic crowns can be efficiently removed from natural teeth without damage to the underlying tooth structure using an Erbium laser. STUDY DESIGN/MATERIALS AND METHODS The ceramic materials used were IPS E.max CAD Lithium-disilicate (LS2 ) (E.max CAD) and IPS E.max ZirCAD Zirconium-oxide (ZrO2 ) (ZirCAD) (Ivoclar, Vivadent, Liechtenstein). Molars, either as stand-alone teeth or placed in an artificial row of teeth, were prepared to receive all-ceramic crowns. Copings and full contour crowns with either featheredge or regular margins were produced. The all-ceramic crowns were bonded to the teeth with Ivoclar Multilink Automix. The time for Er:YAG laser debonding of each crown was then measured. The Er:YAG (LiteTouch, Syneron, Yokneam, Israel) was used with an 1,100 µm diameter fiber tip with energies up to 600 mJ per pulse (wavelength 2,940 nm, 10 Hz repetition rate, pulse duration 100 µs at 126 mJ/pulse, and 400 µs at 590 mJ/pulse). The irradiation was applied at a distance of 10 mm from the crown surface following a defined pattern. Air-water spray was applied to the crowns at a rate of 67 ml/minute. RESULTS All of the all-ceramic crowns were successfully debonded with the laser. On average, an all-ceramic E.max CAD crown was debonded in 190 ± 92 seconds (average ± SD). The debonding time for ZirCAD featheredge crowns was 226 ± 105 seconds and for ZirCAD crowns with regular margins it was 312 ± 102 seconds. No crowns fractured and no damage to the underlying dentin was detected. The bonding cement deteriorated due to the Er:YAG irradiation. Additionally, no carbonization at the dentin/cement interface was observed. CONCLUSION Er:YAG laser energy can successfully be used to efficiently debond all-ceramic full contour crowns from natural teeth without damage to the underlying tooth structure. Lasers Surg. Med. 46:636-643, 2014. © 2014 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Peter Rechmann
- School of Dentistry, Department of Preventive and Restorative Dental Sciences, University of California at San Francisco, 707 Parnassus Avenue, San Francisco, California, 94143
| | | | | | | |
Collapse
|
46
|
Rechmann P, Buu NCH, Rechmann BMT, Le CQ, Finzen FC, Featherstone JDB. Laser all-ceramic crown removal-a laboratory proof-of-principle study-phase 1 material characteristics. Lasers Surg Med 2014; 46:628-35. [PMID: 25125132 DOI: 10.1002/lsm.22279] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/14/2014] [Indexed: 11/09/2022]
Abstract
BACKGROUND AND OBJECTIVES The removal of all-ceramic crowns is a time consuming and destructive procedure in the dental office. The removal of all-ceramic crowns using Er:YAG lasers has not been previously described in the scientific literature. The objective of this laboratory proof-of-principle study was to evaluate whether with regards to absorption and transmission characteristics of bonding cements and ceramics all-ceramic crowns can be removed from natural teeth using an Erbium laser. STUDY DESIGN/MATERIALS AND METHODS The Fourier Transform Infrared Spectroscopy (FTIR) was used on flat ceramic samples (IPS Empress Esthetic (EE), E.max CAD, and E.max ZirCAD) to assess which infrared laser wavelengths transmit through the ceramics. Additionally, FTIR spectra for four bonding cements (Variolink Veneer, Variolink II, Multilink Automix, and SpeedCEM) were obtained. The Er:YAG laser energy transmission (wavelength 2,940 nm, 10 Hz repetition rate, pulse duration 100 µs at 126 mJ/pulse to 300 µs at 508 mJ/pulse) through different ceramic thicknesses was measured. Ablation thresholds for bonding cements were determined. Cement samples were directly irradiated or laser light was transmitted through ceramic samples. RESULTS While the ceramics did not show any characteristic water absorption bands in the FTIR, all bonding cements showed a broad H2 O/OH absorption band. Some cements exhibited a distinct absorption peak at the Er:YAG laser emission wavelength. Depending on the ceramic thickness, EE and E.max CAD ceramics transmitted between 21 and 60% of the incident Er:YAG energy, with E.max CAD transmitting more energy than EE at comparable thicknesses. In contrast, E.max ZirCAD transmitted only 5-10% of the incident energy. Initial signs of cement deterioration occurred at 1.3-2.6 J/cm(2) . Multilink Automix, SpeedCEM, and Variolink II started ablation at 4.4-4.7 J/cm(2) . Variolink Veneer needed 44% less energy for ablation. CONCLUSION Er:YAG laser energy can be transmitted through all-ceramic materials and those transmitted energies are sufficient for ablation of bonding cements.
Collapse
Affiliation(s)
- Peter Rechmann
- School of Dentistry, Department of Preventive and Restorative Dental Sciences, University of California at San Francisco, 707 Parnassus Avenue, San Francisco, California, 94143
| | | | | | | | | | | |
Collapse
|
47
|
Oilo M, Hardang AD, Ulsund AH, Gjerdet NR. Fractographic features of glass-ceramic and zirconia-based dental restorations fractured during clinical function. Eur J Oral Sci 2014; 122:238-44. [PMID: 24698173 PMCID: PMC4199274 DOI: 10.1111/eos.12127] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/10/2014] [Indexed: 11/28/2022]
Abstract
Fractures during clinical function have been reported as the major concern associated with all-ceramic dental restorations. The aim of this study was to analyze the fracture features of glass-ceramic and zirconia-based restorations fractured during clinical use. Twenty-seven crowns and onlays were supplied by dentists and dental technicians with information about type of cement and time in function, if available. Fourteen lithium disilicate glass-ceramic restorations and 13 zirconia-based restorations were retrieved and analyzed. Fractographic features were examined using optical microscopy to determine crack initiation and crack propagation of the restorations. The material comprised fractured restorations from one canine, 10 incisors, four premolars, and 11 molars. One crown was not categorized because of difficulty in orientation of the fragments. The results revealed that all core and veneer fractures initiated in the cervical margin and usually from the approximal area close to the most coronally placed curvature of the margin. Three cases of occlusal chipping were found. The margin of dental all-ceramic single-tooth restorations was the area of fracture origin. The fracture features were similar for zirconia, glass-ceramic, and alumina single-tooth restorations. Design features seem to be of great importance for fracture initiation.
Collapse
Affiliation(s)
- Marit Oilo
- Department of Clinical Dentistry, Faculty of Medicine and Dentistry, University of Bergen, Bergen, Norway
| | | | | | | |
Collapse
|