1
|
Peroz S, Peroz I, Beuer F, von Stein-Lausnitz M, Sterzenbach G. Digital versus conventional complete dentures: A randomized, controlled, double-blinded crossover trial. J Prosthet Dent 2024; 132:132-138. [PMID: 35850871 DOI: 10.1016/j.prosdent.2022.04.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 04/29/2022] [Accepted: 04/29/2022] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM The Baltic Denture System provides a digital way to fabricate complete dentures in 2 visits. Conventional dentures using injection or compression molding require additional visits and complex laboratory procedures. However, how the fabrication method affects clinical outcomes is unclear. PURPOSE The purpose of this clinical, randomized, controlled, double-blinded crossover trial was to evaluate the impact of the fabrication method (digital versus conventional production) of complete dentures on clinical outcomes. MATERIAL AND METHODS Sixteen participants received 2 pairs of new complete dentures, produced in a digital and a conventional workflow. Each complete denture was worn for an observation period of 3 months. The order of the dentures was randomized. The primary outcome was the clinical assessment of the dentures by a blinded examiner, including peripheral extension, cutout for buccal and labial frenula, denture extension, and denture thickness. Denture esthetics were evaluated by the midline, position of anterior teeth, buccal corridor, and smile arc, and occlusal relationships were evaluated by the vertical dimension, sagittal relation, the Camper plane, and occlusion. In addition, the retention of maxillary and mandibular dentures and phonetics was evaluated. Differences between the prostheses were statistically analyzed with the McNemar test (α=.05). RESULTS The borders of the digital dentures were significantly more often overextended at the time of insertion (P=.021), reducing the retention of the digital dentures, especially the maxillary dentures (P=.016). The borders of the dentures could be corrected so that after 2 weeks and 3 months, no significant differences could be seen between digital dentures and conventional dentures. CONCLUSIONS The fabrication method has a significant influence only on the dimension of the denture border. It was significantly more often overextended in digital dentures and impaired retention, especially of the maxillary dentures, at the time of insertion. As this parameter is correctable, no significant clinical differences could be observed over the observation time of 3 months between digital dentures and conventional dentures.
Collapse
Affiliation(s)
- Simon Peroz
- Research Associate, Charité, CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), Berlin, Germany.
| | - Ingrid Peroz
- Professor, Charité, CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), Berlin, Germany
| | - Florian Beuer
- Professor, Charité, CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), Berlin, Germany
| | - Manja von Stein-Lausnitz
- Associate Professor, Charité, CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), Berlin, Germany
| | - Guido Sterzenbach
- Associate Professor, Charité, CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), Berlin, Germany
| |
Collapse
|
2
|
Altarazi A, Haider J, Alhotan A, Silikas N, Devlin H. Impact of Artificial Aging on the Physical and Mechanical Characteristics of Denture Base Materials Fabricated via 3D Printing. Int J Biomater 2024; 2024:8060363. [PMID: 38919543 PMCID: PMC11199068 DOI: 10.1155/2024/8060363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 05/09/2024] [Accepted: 05/31/2024] [Indexed: 06/27/2024] Open
Abstract
Three-dimensional (3D) printing is becoming more prevalent in the dental sector due to its potential to save time for dental practitioners, streamline fabrication processes, enhance precision and consistency in fabricating prosthetic models, and offer cost-effective solutions. However, the effect of aging in artificial saliva of this type of material has not been explored. To assess the physical and mechanical properties of the two types of 3D-printed materials before and after being subjected to artificial saliva, a total of 219 acrylic resin specimens were produced. These specimens were made with two types of 3D-printed materials, namely, NextDent (ND) and Formlabs (FLs), and a Schottlander heat-cured (HC) resin material that was used as a control. Water sorption and solubility specimens (n = 5) were tested after three months of storage in artificial saliva. Moreover, the Vickers hardness, Martens hardness, flexural strength/modulus, and impact strength were evaluated both under dry conditions and after three months of storage in artificial saliva. The degree of conversion (DC), elemental analysis, and filler content were also investigated. The ANOVA showed that 3D-printed resins had significantly greater sorption than the control group (p < 0.05). However, the flexural strength values of the 3D-printed materials were significantly greater (p < 0.05) than those of the heat-cured material. The DC of the 3D-printed resins was lower than that of the control group, but the difference was not significant (p > 0.05). The 3D-printed materials contained significantly more filler than the control (p < 0.05). Moreover, the artificial saliva had a significant effect on the Vickers hardness for all tested groups and on the Martens hardness for the control group only (p < 0.05). Compared with conventional heat-cured materials, 3D-printed denture base materials demonstrated relatively poorer performance in terms of sorption, solubility, and DC but exhibited either comparable or superior mechanical properties. The aging process also influenced the Vickers and Martens' hardness. The strength of the 3D-printed materials was in compliance with ISO recommendations, and the materials could be used alongside conventional heat-cured materials.
Collapse
Affiliation(s)
- Ahmed Altarazi
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
- Restorative Dental Science, College of Dentistry, Taibah University, Medinah, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Nick Silikas
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
| | - Hugh Devlin
- Division of Dentistry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, UK
- School of Dentistry, University of Jordan, Amman, Jordan
| |
Collapse
|
3
|
Ribeiro AKC, de Freitas RFCP, Costa RTF, de Moraes SLD, Srinivasan M, Carreiro ADFP. Maxillomandibular relationship record methods for computer-engineered complete dentures: a scoping review. Clin Oral Investig 2024; 28:320. [PMID: 38750145 DOI: 10.1007/s00784-024-05706-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Accepted: 05/06/2024] [Indexed: 07/03/2024]
Abstract
OBJECTIVES The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.
Collapse
Affiliation(s)
- Anne Kaline Claudino Ribeiro
- Post-graduate student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil
| | | | | | | | - Murali Srinivasan
- Clinic of General-, Special care- and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Adriana da Fonte Porto Carreiro
- Department of Dentistry, Federal University of Rio Grande do Norte, Natal (UFRN), 1787 Salgado Filho Senator Avenue Lagoa Nova, 59056000, Natal, RN, Brazil.
| |
Collapse
|
4
|
Özatik Ş, Bural Alan C. Flexural strength of repaired denture base materials manufactured for the CAD-CAM technique. J Oral Sci 2024; 66:120-124. [PMID: 38494704 DOI: 10.2334/josnusd.23-0275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
PURPOSE To evaluate the flexural properties of repaired poly(methylmethacrylate) (PMMA) denture base materials for computer-aided design/computer-aided manufacturing (CAD-CAM) and to compare them with heat-activated polymerized PMMA. METHODS A total of 288 specimens (65 × 10 × 2.5 mm) were prepared using both CAD-CAM and conventional blocks and repaired using autopolymerizing and visible-light polymerizing (VLC) materials. Microwave energy, water storage and hydroflask polymerization were applied as additional post-polymerization cycles after the repair process. The flexural strength (FS) of the specimens was evaluated using the three-point bending test. Data were evaluated statistically using 2-way ANOVA followed by Bonferroni's correction to determine the significance of differences between the groups (P ≤ 0.05). RESULTS The FS of the denture base materials for CAD-CAM was significantly higher than that for the heat-activated group (P ≤ 0.05). The FS was significantly highest when microwave energy was used for the post-polymerization cycle. The FS values for all groups repaired with VLC resin were significantly lower than for the autopolymerization group (P ≤ 0.05). CONCLUSION The flexural properties of denture base materials for CAD-CAM repaired using autopolymerizing acrylic resins can recover by 50-70%. Additional post-polymerization cycles for autopolymerizing repair resin can be suggested to improve the clinical service properties of repaired dentures.
Collapse
Affiliation(s)
- Şebnem Özatik
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University
| | - Canan Bural Alan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University
| |
Collapse
|
5
|
Jung GK, Mora SN, Yune SS, Petrich A, Hernandez-Feldpausch M, Hamlin CM, Tuamokumo FO, Kim JJ. Effects of aging on attachment of Candida albicans to conventional heat-polymerized, CAD-CAM milled, and CAD-CAM 3D-printed acrylic resin bases. J Prosthodont 2024. [PMID: 38502779 DOI: 10.1111/jopr.13844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 03/03/2024] [Indexed: 03/21/2024] Open
Abstract
PURPOSE The aim of this study was to assess Candida albicans attachment on conventionally fabricated (polymethylmethacrylate, PMMA), CAD-CAM milled, and 3D-printed acrylic resin bases pre- and post-simulated thermal aging, along with examining material surface changes after aging. MATERIALS AND METHODS Forty-six samples (10 mm × 10 mm × 2 mm) for each of four material groups (conventional heat-polymerized PMMA, CAD-CAM milled acrylic resin base, CAD-CAM 3D-printed methacrylate resin base, CAD-CAM 3D-printed urethane methacrylate resin base) were subjected to 0, 1, or 2 years of simulated thermal aging. Microscopic images were taken before and after aging, and C. albicans attachment was quantified using cell proliferation assay (XTT). Statistical analysis employed analysis of variance (α = 0.05). RESULTS Two-way factorial analysis showed no significant differences based on acrylic resin type or thermal aging (p = 0.344 and p = 0.091 respectively). However, C. albicans attachment significantly differed between 0- and 2-year thermally aged groups (p = 0.004), mainly due to elevated initial attachments on CAD-CAM milled acrylic resin base and CAD-CAM 3D-printed urethane methacrylate resin base. CONCLUSIONS Regardless of the fabrication technique and material combination, no significant differences were found in C. albicans adhesion pre- or post- thermal aging. Milled and 3D-printed bases compared favorably with heat- polymerized PMMA in their affinity for C. albicans attachment and surface characteristics after aging. These findings indicate that the risk of patients developing denture stomatitis might not be linked to the type of acrylic resin or fabrication method used.
Collapse
Affiliation(s)
- Gabrielle K Jung
- Department of Prosthodontics, Naval Postgraduate Dental School, Bethesda, Maryland, USA
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
- Navy Medicine Readiness & Training Command, Camp Pendleton, California, USA
| | - Stephanie N Mora
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
- 3D Dental Battalion, US Naval Dental Center, Okinawa, Japan
- Department of Comprehensive Dentistry, Naval Postgraduate Dental School, Bethesda, Maryland, USA
| | - Stephen S Yune
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
- Department of Comprehensive Dentistry, Naval Postgraduate Dental School, Bethesda, Maryland, USA
| | - Anton Petrich
- Department of Prosthodontics, Naval Postgraduate Dental School, Bethesda, Maryland, USA
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
| | - Marina Hernandez-Feldpausch
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
- Department of Comprehensive Dentistry, Naval Postgraduate Dental School, Bethesda, Maryland, USA
| | - Christopher M Hamlin
- Department of Prosthodontics, Naval Postgraduate Dental School, Bethesda, Maryland, USA
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
| | - Francois O Tuamokumo
- Department of Research Programs, Walter Reed National Military Medical Center, Bethesda, Maryland, USA
| | - Jeffrey J Kim
- Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
- Department of Research, Naval Postgraduate Dental School, Bethesda, Maryland, USA
| |
Collapse
|
6
|
Gad MM, Alalawi H, Al-Qarni FD, Al-Harbi FA. Denture relining using digital replication method: A dental technique. J Prosthodont 2024. [PMID: 38403847 DOI: 10.1111/jopr.13832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 02/01/2024] [Indexed: 02/27/2024] Open
Abstract
The aim of this report was to digitize traditional denture relining using a digital duplication method, in addition to assessing the wear resistance of three-dimensional (3D) printed denture teeth. A complete denture was relined using light body impression. The denture with impression was scanned yielding a standard tessellation language file that was designed to print the denture base and teeth. The printed teeth were fitted into the sockets of the printed denture base and then bonded using auto-polymerized acrylic resins, followed by finishing and polishing. Dentures were inserted and fit and occlusion were adjusted as needed, and the patient was scheduled for follow-up appointments at one week, three months, and six months. At each follow-up visit, dentures were scanned using a 3Shape E3 desktop scanner and scans were superimposed. The occlusal wear was assessed in reference to the first scan after the denture insertion visit. The accuracy of the intaglio surface of dentures was within clinically acceptable limits. The clinical evaluation of inserted dentures in terms of retention, occlusion, esthetic, and patient satisfaction was encouraging. Using digital duplication, conventional dentures could be relined. The advantages of digital records include eliminating polymerization dimensional changes, and reducing cost and clinical time by minimizing the number of visits, which is particularly helpful with geriatric patients.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Haidar Alalawi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
7
|
Abdul-Monem MM, Hanno KI. Effect of thermocycling on surface topography and fracture toughness of milled and additively manufactured denture base materials: an in-vitro study. BMC Oral Health 2024; 24:267. [PMID: 38395828 PMCID: PMC10885363 DOI: 10.1186/s12903-024-03991-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 02/06/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND Studies investigating thermocycling effect on surface topography and fracture toughness of resins used in digitally manufactured denture bases are few. The study aimed to assess the impact of thermocycling on surface topography and fracture toughness of materials used for digitally manufactured denture bases. METHODS Water sorption, solubility, hardness, surface roughness, and fracture toughness of both three-dimensional (3D)-printed and computer-aided design, computer-aided manufacturing (CAD-CAM) milled specimens (n = 50) were assessed both prior to and following 2000 thermocycles, simulating 2 years of clinical aging. Surface hardness (n = 10) was measured using a Vickers hardness testing machine, surface roughness (n = 10) was determined by a contact profilometer, and fracture toughness (n = 20) was measured using the 3-point bend test, then studying the fractured surfaces was done via a scanning electron microscope (SEM). Prior to and following thermocycling, water sorption and solubility (n = 10) were assessed. Normally distributed data was tested using two-way repeated ANOVA and two-way ANOVA, while Mann Whitney U test and the Wilcoxon signed ranks test were used to analyze data that was not normally distributed (α < 0.05). RESULTS Following thermocycling, Vickers hardness and fracture toughness of both groups declined, with a significant reduction in values of the 3D-printed resin (P < .001). The 3D-printed denture base resins had a rougher surface following thermocycling with a significant difference (P < .001). The sorption and solubility of water of both materials were not affected by thermocycling. CONCLUSIONS Before and after thermocycling, milled specimens had lower surface roughness and a greater degree of hardness and fracture toughness than 3D-printed specimens. Thermocycling lowered hardness and fracture toughness, and increased surface roughness in both groups, but had no effect on water sorption and solubility.
Collapse
Affiliation(s)
- Mohamed M Abdul-Monem
- Department of Dental Biomaterials, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt
- Division of Dental Biomaterials, Department of Prosthodontics, Faculty of Dentistry, Alamein International University, Alamein, Egypt
| | - Kenda I Hanno
- Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt.
| |
Collapse
|
8
|
Namano S, Kanazawa M, Katheng A, Trang BNH, Hada T, Komagamine Y, Iwaki M, Minakuchi S. Effect of support structures on the trueness and precision of 3D printing dentures: An in vitro study. J Prosthodont Res 2024; 68:114-121. [PMID: 37019646 DOI: 10.2186/jpr.jpr_d_22_00266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
Purpose Additive manufacturing has revolutionized the fabrication of complete dentures. However, this process involves support structure, which is a construction part that holds the specimen during printing, and may prove to be disadvantageous. Therefore, this in vitro study compared the effect of support structure reduction on various volume and area distributions of a 3D-printed denture base to determine optimal parameters based on accuracy.Methods A complete maxillary denture base construction file was used as reference. Twenty denture bases were 3D printed under four conditions (total n=80): no support structure reduction (control), palatal support structure reduction (Condition P), border support structure reduction (Condition B), and palatal and border support structure reduction (Condition PB). Printing time and resin consumption were also recorded. The intaglio surface trueness and precision of all acquired data were exported to a 3D analysis software, and the dimensional changes to the denture base were analyzed using the root-mean-square estimate (RMSE) to assess geometric accuracy and generate color map patterns. Nonparametric Kruskal-Wallis and Steel-Dwass tests (α=0.05) analyzed the accumulated data.Results Control had the lowest RMSE values for trueness and precision. Nevertheless, it demonstrated a significantly lower RMSE than that of Condition B (P=0.02) in precision. Owing to negative deviation at the palatal region, Conditions P and PB had higher retention than Control and Condition B regarding the color map pattern.Conclusions Within the limitations of this study, the reduction of palatal and border support structures showed optimal accuracy with resource and cost savings.
Collapse
Affiliation(s)
- Sahaprom Namano
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Manabu Kanazawa
- Digital Dentistry Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | | | - Bui Ngoc Huyen Trang
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tamaki Hada
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuriko Komagamine
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Maiko Iwaki
- Digital Dentistry Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Shunsuke Minakuchi
- Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
9
|
Al-Kaff FT, Al Hamad KQ. Additively manufactured CAD-CAM complete dentures with intraoral scanning and cast digitization: A controlled clinical trial. J Prosthodont 2024; 33:27-33. [PMID: 37200587 DOI: 10.1111/jopr.13704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 05/12/2023] [Accepted: 05/12/2023] [Indexed: 05/20/2023] Open
Abstract
PURPOSE To assess, clinically, patient satisfaction of additively manufactured complete dentures with intraoral scanning and hybrid cast digitization in comparison with conventional complete dentures. MATERIALS AND METHODS Participants who were edentulous in both arches were recruited and received three types of complete dentures (CDs): conventionally manufactured with conventional impression (CC), additively manufactured with intraoral scanning (AMI), and additively manufactured with cast digitization (AMH). Definitive impressions of the edentulous arches were made with medium viscosity polyvinyl siloxane (Hydrorise Monophase; Zhermack, Italy) for the CC group, intraoral scanning (TRIOS 4; 3Shape, Copenhagen, Denmark) for the AMI group, and laboratory scanning of the definitive casts (Ceramill Map400 AMANNGIRRBACH, Pforzheim, Deutschland) for the AMH group. The trial dentures of the CC group were scanned for occlusion registrations of the AMI and AMH groups and were used to guide the designing process (Exocad 3.0 Galway; Exocad GmbH). The AMI and AMH dentures were additively manufactured with a vat-polymerization 3D printer (Sonic XL 4K; phrozen, Taiwan). Patient satisfaction and clinical outcome were assessed with OHIP EDENT, and 14-factor criteria, respectively. Statistical analyses were performed with paired sample t-test and one-way repeated measure ANOVA for satisfaction, Wilcoxon signed rank test for clinical outcome, and Pearson's r (r) for effect size, with α = 0.05. RESULTS A total of 20 participants were included. Satisfaction had no statistically significant difference within or among the groups (p < 0.105). Within-group comparison between the two arches showed no statistical significance for the clinical outcome except for a significantly higher maxillary AMI score (p = 0.01, r = -0.40 with medium effect size). For among group's comparison; AMI had a significantly lower score than CC for the maxillary and mandibular arches (p = 0.01, r = -0.40, medium effect size, and p = 0.003, r = -0.47, medium effect size), and significantly lower score than the mandibular AMH (p = 0.03, r = -0.47, medium effect size), with significantly lower quality in teeth arrangement and retention domains for the AMI, and teeth arrangement for the AMH, in comparison with CC. CONCLUSIONS Patient satisfaction with both types of additively manufactured dentures is comparable to conventional dentures. The comparable overall clinical outcomes between hybrid and conventional dentures indicate that additive manufacturing is an acceptable clinical substitute for the conventional methods. However, additively manufactured dentures made with intraoral scanning have lower clinical quality and retention than hybrid and conventional dentures, particularly for the mandibular arch. Teeth arrangement of both additively manufactured dentures is clinically inferior to the conventional denture.
Collapse
Affiliation(s)
- Fatma T Al-Kaff
- Department of Prosthodontics, Jordan University of Science & Technology, Irbid, Jordan
| | - Khaled Q Al Hamad
- Department of Prosthodontics, Jordan University of Science & Technology, Irbid, Jordan
| |
Collapse
|
10
|
Alehaideb A, Lin WS, Levon JA, Chu TMG, Yang CC. Accuracy of digital duplication scanning methods for complete dentures. J Prosthodont 2023. [PMID: 37924229 DOI: 10.1111/jopr.13788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 10/20/2023] [Accepted: 10/27/2023] [Indexed: 11/06/2023] Open
Abstract
PURPOSE To compare the accuracy of four digital scanning methods in duplicating a complete denture. MATERIAL AND METHODS Four scanning methods were used: cone beam computed tomography (CBCT), Straumann desktop scanner (DS), Trios intraoral scanner (TIO), and Virtuo Vivo intraoral scanner (VVIO). Each method was used to duplicate all the surfaces of a printed complete denture. The denture was scanned 10 times in each group. The trueness (in root mean square, RMS) and precision (in standard deviation, SD) were calculated by comparing the combined dentition, denture extension, and intaglio surfaces with the reference file. One-way analysis of variance and F-tests were used to test statistical differences (α = 0.05). RESULTS For the scanning accuracy of the whole denture, CBCT showed the highest RMS (0.249 ± 0.020 mm) and lowest trueness than DS (0.124 ± 0.014 mm p < 0.001), TIO (0.131 ± 0.006 mm p < 0.001), and VVIO (0.227 ± 0.020 mm p = 0.017), while DS and TIO showed smaller RMS than VVIO (p < 0.001). For the trueness of dentition, denture extension, and intaglio surfaces, CBCT also showed the highest mean RMS and lowest trueness among all groups (p < 0.001). DS and TIO had smaller mean RMS and higher trueness among all groups in all surfaces (p < 0.001, except VVIO in intaglio surface, p > 0.05). TIO had significantly lower within-group variability of RMS and highest precision compared to DS (p = 0.013), CBCT (p = 0.001), and VVIO (p < 0.001) in the combined surface. For dentition and denture extension surfaces, TIO showed similar within-group variability of RMS with the DS group (p > 0.05) and lower than CBCT and VVIO (p < 0.001). CONCLUSION The 7 Series desktop scanner and Trios 4 intraoral scanner can duplicate dentures in higher trueness than CBCT and the Virtuo Vivo intraoral scanner. The Trios 4 intraoral scanner was more precise in the combined surfaces than other scanning methods, while the 7 Series desktop scanner and Trios 4 intraoral scanner were more precise in the denture extension surface.
Collapse
Affiliation(s)
- Abdullah Alehaideb
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Wei-Shao Lin
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - John A Levon
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Tien-Min G Chu
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Chao-Chieh Yang
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| |
Collapse
|
11
|
Aydin N, Uslu Kavrama F, Yosuncigir H, Ucar Y. A comparison of the shear bond strength between denture teeth and denture base resins manufactured either conventionally or with a 3D printer. J Prosthet Dent 2023; 130:742.e1-742.e6. [PMID: 37743140 DOI: 10.1016/j.prosdent.2023.08.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/29/2023] [Accepted: 08/30/2023] [Indexed: 09/26/2023]
Abstract
STATEMENT OF PROBLEM Limited information is available on the shear bond strength (SBS) between denture teeth and denture base resins fabricated using a stereolithography (SLA) 3-dimensional (3D) printer. PURPOSE The purpose of this in vitro study was to evaluate the SBS between denture teeth and the denture base resins produced with the conventional method and with a 3D printer. MATERIAL AND METHODS Conventional or 3D printed denture teeth were included in the study. The denture base resins were manufactured either conventionally or with a 3D printer. Four subgroups were tested: conventional teeth-conventional base resin (CT-CB), conventional teeth-printed base resin (CT-PB), printed teeth-conventional base resin (PT-CB), and printed teeth-printed base resin (PT-PB). The maxillary molars were combined with Ø5×2.5-mm-cylindrical denture base resin. Shear bond testing was performed by applying a parallel force to the denture teeth-denture base resin interface by using a blade-edge chisel with a crosshead speed of 1 mm/min until failure occurred. SBS and elastic modulus (EM) were recorded. One-way ANOVA followed by the Dunnett T3 post hoc test was used for the statistical analysis (α=.05). The failure modes of the specimens were also analyzed. RESULTS A statistically significant difference (P<.05) was found between the evaluated groups for the SBS and EM values. PT-PB showed the highest SBS value (15.4 ±2.7 MPa), and CT-PB showed the lowest (0.9 ±0.7 MPa). The PT-CB group showed the highest EM value (62.74 ±20.80 GPa), and the CT-PB group showed the lowest (29.46 ±28.40 GPa). The CT-CB and CT-PB specimens showed mostly adhesive failure; none of the PT-PB specimens showed adhesive failure. CONCLUSIONS Three-dimensional printing led to a better bond between the denture teeth and the denture base resin compared with the conventional method. Although these findings need to be supported by clinical studies, the use of 3D printers is appropriate in the production of denture teeth and denture bases.
Collapse
Affiliation(s)
- Nazli Aydin
- Lecturer, Cukurova University, Faculty of Dentistry, Department of Prosthodontics, Adana, Turkey; and Abdi Sutcu Vocational School of Health Services, Cukurova University, Balcali, Adana, Turkey.
| | | | - Halit Yosuncigir
- R&D and Product Manager, SINERG Lokman Hekim University, Ankara, Turkey
| | | |
Collapse
|
12
|
Hanno KI, Abdul-Monem MM. Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study. J Prosthet Dent 2023; 130:798.e1-798.e8. [PMID: 37716896 DOI: 10.1016/j.prosdent.2023.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 08/08/2023] [Accepted: 08/11/2023] [Indexed: 09/18/2023]
Abstract
STATEMENT OF PROBLEM Studies on the impact of denture cleansers on the physical and mechanical properties of denture bases designed and constructed by using computer software programs are lacking. PURPOSE The purpose of this in vitro study was to test the effect of a peroxide denture cleanser on the hardness, fracture toughness, water sorption, and solubility of denture base materials manufactured by 3D printing and computer-aided design and computer-aided manufacturing (CAD-CAM) milling. MATERIAL AND METHODS The hardness, fracture toughness, water solubility, and sorption of CAD-CAM milled and 3D printed groups (n=40) were evaluated before and after exposure to a denture cleanser. Hardness (n=10) was analyzed with a Vickers hardness testing machine, and fracture toughness (n=20) with the 3-point bend test. After the fracture of specimens, a scanning electron microscope at ×300 was used for fractographic analysis. Water sorption and solubility (n=10) were evaluated before and after immersion in denture cleanser for 6 days to simulate 180 days of immersion. Two-way repeated ANOVA and 2-way ANOVA were used to test normally distributed data, whereas the Mann Whitney U test and Wilcoxon signed ranks test were used for data that were not normally distributed (α<.05). RESULTS The Vickers hardness and fracture toughness of both materials decreased after immersion in denture cleansers, with a higher decrease in values for the 3D printed group (P<.001). The denture cleanser had no effect on the water sorption and solubility of either group. CONCLUSIONS Milled specimens had higher hardness values and fracture toughness before and after immersion in the denture cleanser. Denture cleansers resulted in the reduced hardness and fracture toughness of both groups, but the percentage change in the milled group was lower. Denture cleansers had no effect on water sorption or solubility.
Collapse
Affiliation(s)
- Kenda I Hanno
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt.
| | - Mohamed M Abdul-Monem
- Lecturer, Department of Dental Biomaterials, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt; Lecturer, Division of Dental Biomaterials, Department of Prosthodontics, Faculty of Dentistry, Alamein International University, Alamein, Egypt
| |
Collapse
|
13
|
Dib Zakkour S, Dib Zakkour J, Guadilla Y, Montero J, Dib A. Comparative Evaluation of the Digital Workflow and Conventional Method in Manufacturing Complete Removal Prostheses. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6955. [PMID: 37959552 PMCID: PMC10650844 DOI: 10.3390/ma16216955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 09/10/2023] [Accepted: 10/27/2023] [Indexed: 11/15/2023]
Abstract
The aging population in developed countries has increased the number of edentulous patients and, therefore, the need for prosthetic rehabilitation to improve their quality of life. Complete dentures are the main treatment option in these cases. The use of CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) in dentistry has improved clinical protocols and outcomes, achieving a reduction in work time and economic costs for the patients. The main objective of this review was to compare the characteristics of conventional and digital dentures, attempting to determine whether the use of new technologies represents an improvement in the properties of removable complete dentures. A bibliographic review was carried out in the PubMed/MEDLINE, Cochrane Library, Scielo, and Embase databases. With the initial search, 157 articles were obtained. After applying the inclusion and exclusion criteria, 64 publications were selected for this bibliographic review. The different conclusions of the studies consulted were compared regarding fit and retention, fracture resistance, surface roughness, biocompatibility, and aesthetics, taking into account the different methods of prostheses fabrication. In general, digital prostheses have shown better mechanical properties and, consequently, better biocompatibility and aesthetics than conventional prostheses. However, the obtained results were very heterogeneous, preventing a supported conclusion.
Collapse
Affiliation(s)
| | | | - Yasmina Guadilla
- Dental Clinic of the Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain; (Y.G.); (J.M.); (A.D.)
| | - Javier Montero
- Dental Clinic of the Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain; (Y.G.); (J.M.); (A.D.)
| | - Abraham Dib
- Dental Clinic of the Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain; (Y.G.); (J.M.); (A.D.)
| |
Collapse
|
14
|
Pereira ALC, Troconis CCM, Curinga MRS, Curinga MASE, Barão VAR, Carreiro ADFP. Bond strength between denture lining material and CAD-CAM denture base resin: A systematic review and meta-analysis. J Prosthet Dent 2023:S0022-3913(23)00607-8. [PMID: 37845114 DOI: 10.1016/j.prosdent.2023.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 08/31/2023] [Accepted: 09/01/2023] [Indexed: 10/18/2023]
Abstract
STATEMENT OF PROBLEM An effective bond between a denture lining material and the denture base resin is necessary for proper function. Regarding the new technologies for manufacturing denture bases, a systematic search of the literature on this topic is lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the bond strength between denture lining material and computer-aided design and computer-aided manufacturing (CAD-CAM) denture base resin (milled and 3-dimensionally printed) versus conventional denture base resin. MATERIAL AND METHODS Electronic databases (PubMed/MEDLINE, Scopus, and Web of Science) were independently searched by 4 researchers for relevant studies published up to April 2023. The population, intervention, comparison, and outcome (PICO) question was: "Comparing conventional and CAD-CAM (milled and 3-dimensionally printed) denture base materials, which promote greater bond strength when associated with denture lining material?" A meta-analysis was performed based on mean ±standard deviation bond strength values between denture base resins and denture lining material with 95% confidence intervals. RESULTS Five in vitro studies were included. For bond strength, no difference was noted between conventional and milled denture base resin (confidence interval: -0.99 [-2.17 to 0.20]; heterogeneity: t2=0.57; Chi2:4.57; I2=78%; P=.10), and conventional resin had better values compared with those of 3-dimensionally (3D) printed (confidence interval: 3.03 [2.40-3.66]; heterogeneity: t2=0.00; Chi2:0.56; I2=0%; P<.001) when relined with soft materials. The milled denture base resin was better than the conventional (confidence interval: -0.85 [-1.33 to -0.38]; heterogeneity: Chi2:28.87; I2=93%; P<.001), with no difference between 3D printed and conventional (confidence interval: 0.18 [-4.23 to 4.59]; heterogeneity: t2=16.51; Chi2:130.99; I2=98%; P=.94) for hard liners. CONCLUSIONS The bond strength between resins for milled CAD-CAM denture bases and denture lining material was similar to that of conventional denture base resin, regardless of the consistency of the denture lining material. The bond strength to 3D printed CAD-CAM resin was lower than that of the milled version.
Collapse
Affiliation(s)
| | | | | | | | - Valentim A R Barão
- Associate Professor, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Brazil
| | | |
Collapse
|
15
|
Mohamed A, Takaichi A, Kajima Y, Takahashi H, Wakabayashi N. Bond strength of CAD/CAM denture teeth to a denture base resin in a milled monolithic unit. J Prosthodont Res 2023; 67:610-618. [PMID: 36725051 DOI: 10.2186/jpr.jpr_d_22_00190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Purpose Herein, the bond strength (BS) of denture teeth to a denture base resin in a milled monolithic unit was investigated and compared with those of 3D printed teeth to a 3D printed denture base and prefabricated teeth to a heat-cured acrylic resin before and after thermocycling.Methods Sixty specimens of a denture tooth attached to a cylindrical denture base were fabricated following ISO Standard 19736. Three fabrication techniques-3D printing, conventional compression molding, and milling using monolithic technology-were employed to mill teeth and denture base parts as a single unit. The BS was investigated before and after thermocycling. Data were statistically analyzed using the Kruskal-Wallis test with Bonferroni correction (α = 0.05).Results Before thermocycling, the mean BS of the milled group was significantly higher than that of the conventional group (P = 0.002). The 3D printed group showed no statistically significant difference from the milled (P = 0.051) and conventional (P = 0.824) groups. After thermocycling, although the mean BS values of the milled (P = 0.00) and 3D printed
(P = 0.01) groups were significantly higher than that of the conventional group, there was no significant difference between them (P = 0.226). Only the BS of the conventional group was significantly reduced by thermocycling (P = 0.00).Conclusions The milled monolithic fabrication technique, which eliminates the need for a bonding step, offered a promising combination of high-precision digital fabrication and a significantly high BS. The BS of the conventional group significantly decreased after thermocycling.
Collapse
Affiliation(s)
- Amr Mohamed
- Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Atsushi Takaichi
- Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yuka Kajima
- Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Hidekazu Takahashi
- Course for Oral Health Engineering, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo, Japan
| | - Noriyuki Wakabayashi
- Advanced Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
16
|
Erbulak Z, Ergun G. The effects of different surface treatments applied to milled PMMA denture base material on repair bond strength. Odontology 2023; 111:953-970. [PMID: 37016128 DOI: 10.1007/s10266-023-00806-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 03/14/2023] [Indexed: 04/06/2023]
Abstract
The high cost of CAD/CAM systems and materials is a severe economic burden. Therefore, repair of CAD/CAM PMMA, selecting appropriate repair materials, and surface modifications are clinically important. This study aims to evaluate the shear bond strength of PMMA repair materials after various surface treatments on CAD/CAM PMMA denture base material. For this purpose, a total of 480 CAD/CAM PMMA denture base test specimens were manufactured. Then all test specimens were divided into 6 groups, and different surface treatments were applied. Group A: sandblasting, Group B: 4% hydro fluoric acid, Group C: tungsten carbide bur, Group D: dichloromethane + methyl methacrylate mixture, Group E: dichloromethane and methyl methacrylate, Group F: no surface treatment. Each group is then divided into 4 different subcategories; repair processes were performed using; heat-cured acrylic resin (n:20), auto-polymerized acrylic resin (n:20), gingiva composite (n:20), and CAD/CAM PMMA tooth material (n:20). After repairs, thermal aging was applied to half of the test specimens in each subcategory. The shear bond strength value was measured with a universal test device. Sandblasting group showed the highest surface roughness value in all test specimens (p < 0.001). Heat-cured acrylic resin with sandblasting exhibited the highest bond strength, while the untreated gingiva composite resin exhibited the lowest value. Thermal aging decreased bond strength in all repair materials (p < 0.001). Among the surface treatment groups, sandblasting with Al2O3 particles exhibited the highest surface roughness value and repair bond strength. The application of organic solvents to the surface increased the surface roughness and repair bond strength. Applying dichloromethane and methyl methacrylate monomer separately is more effective than applying it as a mixture. The ideal bonding among repair materials was obtained with heat-cured acrylic resin.
Collapse
Affiliation(s)
- Zahıde Erbulak
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Bişkek Cad. 1.Sk. No:4 06490 Emek, Ankara, Turkey.
| | - Gulfem Ergun
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Bişkek Cad. 1.Sk. No:4 06490 Emek, Ankara, Turkey
| |
Collapse
|
17
|
Tushar, Rani P, Ananya, Kumar S, Prakash J, B JM. Evaluation of Impact Strength and Flexural Strength of Polyether Ether Ketone vs. Computer-Aided Design/Computer-Aided Manufacturing Polymethyl Methacrylate Denture Base Materials: An In-Vitro Study. Cureus 2023; 15:e47929. [PMID: 38046488 PMCID: PMC10689121 DOI: 10.7759/cureus.47929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/27/2023] [Indexed: 12/05/2023] Open
Abstract
OBJECTIVE The objective is to comparatively assess the impact strength and flexural strength of polyether ether ketone (PEEK) vs. computer-aided design/computer-aided manufacturing (CAD/CAM) polymethyl methacrylate denture base material. METHODS A total of 90 samples were fabricated with traditional heat cure PMMA, PEEK, and CAD/CAM PMMA and divided into three groups of 30 samples each. The impact strength of all the samples was measured using an Izod impact tester with a pendulum in the air at 23±2°C. A three-point bending test was used in a Universal Testing Machine to assess the flexural strength of all the samples. The impact strength and flexural strength mean values were computed using a one-way ANOVA test. RESULT Impact strength and flexural strength of PEEK (IS=10.22±1.25 kJ/m2 and FS=120±8.0 MPa) is almost identical to CAD/CAM PMMA sample (IS=9.595±3.313 kJ/m2 and FS=118.11±5.00 MPa) whereas for conventional heat cure PMMA (IS=4.00±.011 kJ/m2 and FS=75.4±4.50 MPa) the values are least among the three. CONCLUSION PEEK or CAD/CAM PMMA share almost identical and superior mechanical properties, and both can be used as better alternatives for complete denture fabrication rather than using conventional heat cure PMMA.
Collapse
Affiliation(s)
- Tushar
- Prosthodontics, Dental College, Rajendra Institute of Medical Sciences, Ranchi, IND
| | - Priya Rani
- Prosthodontics, Dental College, Rajendra Institute of Medical Sciences, Ranchi, IND
| | - Ananya
- Prosthodontics, Dental College, Rajendra Institute of Medical Sciences, Ranchi, IND
| | - Surender Kumar
- Prosthodontics, Dental College, Rajendra Institute of Medical Sciences, Ranchi, IND
| | | | - Jayaprakash M B
- Prosthodontics, Dental College, Rajendra Institute of Medical Sciences, Ranchi, IND
| |
Collapse
|
18
|
Lee EH, Lim YJ, Kwon HB, Kim MJ. Improving wear resistance of acrylic resin denture teeth by using zirconia complete crowns fabricated with a CAD-CAM double-scanning method: A clinical report. J Prosthet Dent 2023; 130:273-277. [PMID: 35184883 DOI: 10.1016/j.prosdent.2022.01.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 01/01/2022] [Accepted: 01/04/2022] [Indexed: 11/22/2022]
Abstract
Acrylic resin denture teeth can wear and chip when opposed by zirconia prostheses. This clinical report describes the use of zirconia complete crowns to prevent these problems. The predictability of treatment was improved by using the computer-aided design and computer-aided manufacturing (CAD-CAM) double-scanning method.
Collapse
Affiliation(s)
- Eun-Hyuk Lee
- Research Associate, Dental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Young-Jun Lim
- Professor, Dental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Ho-Beom Kwon
- Professor, Dental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Myung-Joo Kim
- Professor, Dental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea.
| |
Collapse
|
19
|
Lee WJ, Jo YH, Yoon HI. Influence of postpolymerization time and atmosphere on the mechanical properties, degree of conversion, and cytotoxicity of denture bases produced by digital light processing. J Prosthet Dent 2023; 130:265.e1-265.e7. [PMID: 37353410 DOI: 10.1016/j.prosdent.2023.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/14/2023] [Accepted: 05/16/2023] [Indexed: 06/25/2023]
Abstract
STATEMENT OF PROBLEM Studies on the effects of postprocessing conditions on the physical properties, degree of conversion (DC), and biocompatibility of denture bases produced by digital light processing are lacking. PURPOSE The purpose of this in vitro study was to evaluate the effects of the atmosphere during postpolymerization and of postpolymerization time on the flexural strength, Vickers hardness, DC, cytotoxicity, and residual monomer content of denture bases. MATERIAL AND METHODS Six different groups of bar- and disk-shaped specimens from the denture base resin were produced, considering 2 different atmospheres (air and nitrogen) and 3 different postpolymerization times (5, 10, and 20 minutes). To determine the physical properties, the flexural strength and Vickers hardness were measured. Fourier transform infrared spectrometry was used to calculate DC. Cytotoxicity was assessed from the effect on human gingival fibroblasts. The residual monomer content was determined by using high-performance liquid chromatography. Based on the normality test by the Shapiro-Wilk method, a nonparametric factorial analysis of variances was conducted (α=.05). RESULTS A significant interaction was detected between the atmosphere and postpolymerization time for hardness (P<.001) but no interaction for strength, DC, or cytotoxicity (P=.826, P=.786, and P=.563, respectively). Hardness was significantly affected by the postpolymerization time in the groups with the nitrogen atmosphere (P<.001). DC was significantly affected by the atmosphere (P=.012), whereas strength and cytotoxicity were not (P=.500 and P=.299, respectively). Cytotoxicity was significantly affected by the postpolymerization time (P<.001), but strength and DC were not (P=.482 and P=.167, respectively). Residual monomers were not detected after ≥10-minute postpolymerization time. CONCLUSIONS The atmosphere significantly affected hardness and DC, whereas the postpolymerization time significantly affected hardness, DC, cytotoxicity, and residual monomer content. Denture bases produced in a nitrogen atmosphere and with the 10-minute postpolymerization time showed sufficient hardness, DC, and no cytotoxicity.
Collapse
Affiliation(s)
- Won-Jun Lee
- Graduate student, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Ye-Hyeon Jo
- Senior Researcher, Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Hyung-In Yoon
- Associate Professor, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea; Adjunct Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
20
|
Carvalho Porto de Freitas RF, Claudino Ribeiro AK, Carneiro Pereira AL, Florêncio Costa RT, Dutra V, Lin WS, Dantas de Moraes SL, da Fonte Porto Carreiro A. Workflow for complete dentures fabrication in three appointments: A dental technique. J Prosthet Dent 2023; 130:164-170. [PMID: 34865836 DOI: 10.1016/j.prosdent.2021.10.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 10/26/2021] [Accepted: 10/26/2021] [Indexed: 10/19/2022]
Abstract
This technical report describes a novel workflow for complete denture fabrication designed to abbreviate the necessary steps for dental prostheses delivery by using a 3-appointment protocol in which preliminary impressions are made in the first session together with the registration of maxillary lip support, occlusal plane, and reference lines for tooth arrangement. A trial denture is fabricated with conventional or computer-aided design and computer-aided manufacturing procedures and is evaluated in the second appointment for esthetics, the definitive impression, and the maxillomandibular relationship record to provide precise references for definitive denture fabrication.
Collapse
Affiliation(s)
| | - Anne Kaline Claudino Ribeiro
- PhD student, Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Rio Grande do Norte, Brazil
| | - Ana Larisse Carneiro Pereira
- PhD student, Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Rio Grande do Norte, Brazil
| | | | - Vinicius Dutra
- Clinical Associate Professor, Department of Oral Pathology, Medicine and Radiology, Indiana University School of Dentistry, Indianapolis, Ind
| | - Wei-Shao Lin
- Associate Professor, Program Director and Interim Chair, Advanced Education Program in Prosthodontics, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind
| | - Sandra Lúcia Dantas de Moraes
- Associate Professor, Division of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Brazil
| | | |
Collapse
|
21
|
Tzanakakis EG, Pandoleon P, Sarafianou A, Kontonasaki E. Adhesion of Conventional, 3D-Printed and Milled Artificial Teeth to Resin Substrates for Complete Dentures: A Narrative Review. Polymers (Basel) 2023; 15:polym15112488. [PMID: 37299286 DOI: 10.3390/polym15112488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 05/16/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND One type of failure in complete or partial dentures is the detachment of resin teeth from denture base resin (DBR). This common complication is also observed in the new generation of digitally fabricated dentures. The purpose of this review was to provide an update on the adhesion of artificial teeth to denture resin substrates fabricated by conventional and digital methods. METHODS A search strategy was applied to retrieve relevant studies in PubMed and Scopus. RESULTS Chemical (monomers, ethyl acetone, conditioning liquids, adhesive agents, etc.) and mechanical (grinding, laser, sandblasting, etc.) treatments are commonly used by technicians to improve denture teeth retention with controversial benefits. Better performance in conventional dentures is realized for certain combinations of DBR materials and denture teeth after mechanical or chemical treatment. CONCLUSIONS The incompatibility of certain materials and lack of copolymerization are the main reasons for failure. Due to the emerging field of new techniques for denture fabrication, different materials have been developed, and further research is needed to elaborate the best combination of teeth and DBRs. Lower bond strength and suboptimal failure modes have been related to 3D-printed combinations of teeth and DBRs, while milled and conventional combinations seem to be a safer choice until further improvements in printing technologies are developed.
Collapse
Affiliation(s)
- Emmanouil-George Tzanakakis
- Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Panagiotis Pandoleon
- Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Aspasia Sarafianou
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon Str., 11527 Athens, Greece
| | - Eleana Kontonasaki
- Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
22
|
Suvarna S, Bedrossian AE, Xu Q, Kuykendall W, Ramos V, Sorenson JA, Chung KH. Effect of Fiber Reinforcement on the Flexural Strength of the Transitional Implant-Supported Fixed Dental Prosthesis. J Prosthodont 2023; 32:139-146. [PMID: 35315177 DOI: 10.1111/jopr.13507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Accepted: 03/10/2022] [Indexed: 11/27/2022] Open
Abstract
PURPOSE The aim of this in vitro study was to assess the efficacy of fiber reinforcement to enhance flexural strength of the transitional implant-supported fixed dental prosthesis (TISFDP). MATERIALS AND METHODS One hundred and forty denture acrylic resin plates (64 mm × 12 mm × 5 mm) with two 7 mm diameter holes were fabricated using heat-polymerized type (Lucitone 199) and CAD-CAM prepolymerized type (AvaDent) materials to simulate a chair-side reconstruction of the TISFDP. Specimens were divided into 7 groups (n = 10) according to the airborne-particle abrasion of titanium cylinder (Straumann) surface and locations of fiber reinforcement ribbons (Ribbond-ULTRA). No cylinder surface abrasion and no fiber added acrylate specimens were used as the controls. The prosthetic screws were hand-tightened on a custom fixture with analogs. Specimen hole and cylinder were joined using a 50:50 mixture of chemically polymerized resin (QYK-SET; Holmes Dental) and repair resin (Dentsply Sirona). Ten acrylate specimens with no holes were fabricated from each tested material and assigned as positive controls. A modified four-point bending test (ASTM standard-D6272) was conducted using a universal testing machine and a custom fixture with a crosshead speed 1 mm/min. The maximum failure loads were recorded. Data were statistically analyzed using 2-way ANOVA and the Tukey tests at α = 0.05. RESULTS The flexural strength values ranged from 55.4 ±8.3 to 140.9 ±15.4 MPa. The flexural strength decreased significantly when fiber was attached on the titanium cylinder surface (p < 0.05). There were no statistically significant differences in flexural strength values between specimens with and without titanium cylinder surface abrasion (p > 0.05). Statistically significant improvement in flexural strength was observed in specimens with fibers attached around the specimen holes (p < 0.05) buccally and lingually. The obtained values were not statistically significantly different from the positive controls (p > 0.05). Some fixation screw fractures were observed before catastrophic failure of specimens during testing. CONCLUSIONS Fiber reinforcement significantly improved the flexural strength of denture acrylic resins only if placed around the specimen holes on the tension side at the site of initiation of crack propagation. Even when the specimens underwent catastrophic failure, the segments remained attached to each other with the attached fibers.
Collapse
Affiliation(s)
- Shivani Suvarna
- Department of Restorative Dentistry, Graduate Prosthodontics, School of Dentistry, University of Washington, Seattle, WA
| | - Armand E Bedrossian
- Department of Restorative Dentistry, Graduate Prosthodontics, School of Dentistry, University of Washington, Seattle, WA
| | - Qianhui Xu
- Department of Epidemiology, Columbia University Mailman School of Public Health, New York, NY
| | - William Kuykendall
- Mechanical Engineering Department, University of Washington, Seattle, WA
| | - Van Ramos
- Department of Restorative Dentistry, Graduate Prosthodontics, School of Dentistry, University of Washington, Seattle, WA
| | - John A Sorenson
- Department of Restorative Dentistry, Graduate Prosthodontics, School of Dentistry, University of Washington, Seattle, WA
| | - Kwok-Hung Chung
- Department of Restorative Dentistry, Graduate Prosthodontics, School of Dentistry, University of Washington, Seattle, WA
| |
Collapse
|
23
|
Ciocca L, Maltauro M, Cimini V, Breschi L, Montanari A, Anderlucci L, Meneghello R. Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologies. J Adv Prosthodont 2023; 15:22-32. [PMID: 36908755 PMCID: PMC9992699 DOI: 10.4047/jap.2023.15.1.22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 01/17/2023] [Accepted: 02/09/2023] [Indexed: 03/06/2023] Open
Abstract
PURPOSE Digital technology has enabled improvements in the fitting accuracy of denture bases via milling techniques. The aim of this study was to evaluate the trueness and precision of digital and analog techniques for manufacturing complete dentures (CDs). MATERIALS AND METHODS Sixty identical CDs were manufactured using different production protocols. Digital and analog technologies were compared using the reference geometric approach, and the Δ-error values of eight areas of interest (AOI) were calculated. For each AOI, a precise number of measurement points was selected according to sensitivity analyses to compare the Δ-error of trueness and precision between the original model and manufactured prosthesis. Three types of statistical analysis were performed: to calculate the intergroup cumulative difference among the three protocols, the intergroup among the AOIs, and the intragroup difference among AOIs. RESULTS There was a statistically significant difference between the dentures made using the oversize process and injection molding process (P < .001), but no significant difference between the other two manufacturing methods (P = .1227). There was also a statistically significant difference between the dentures made using the monolithic process and the other two processes for all AOIs (P = .0061), but there was no significant difference between the other two processes (P = 1). Within each group, significant differences among the AOIs were observed. CONCLUSION The monolithic process yielded better results, in terms of accuracy (trueness and precision), than the other groups, although all three processes led to dentures with Δ-error values well within the clinical tolerance limit.
Collapse
Affiliation(s)
- Leonardo Ciocca
- Oral and Maxillo-Facial Prosthodontics, Section of Prosthodontics, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Mattia Maltauro
- Department of Management and Engineering, University of Padova, Vicenza, Italy
| | - Valerio Cimini
- Oral and Maxillo-Facial Prosthodontics, Section of Prosthodontics, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Lorenzo Breschi
- Oral and Maxillo-Facial Prosthodontics, Section of Prosthodontics, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Angela Montanari
- Department of Statistical Sciences, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Laura Anderlucci
- Department of Statistical Sciences, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Roberto Meneghello
- Department of Management and Engineering, University of Padova, Vicenza, Italy
| |
Collapse
|
24
|
Tinastepe N, Malkondu O, Kazazoglu E. Hardness and surface roughness of differently processed denture base acrylic resins after immersion in simulated gastric acid. J Prosthet Dent 2023; 129:364.e1-364.e9. [PMID: 36604260 DOI: 10.1016/j.prosdent.2022.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 11/30/2022] [Accepted: 12/01/2022] [Indexed: 01/04/2023]
Abstract
STATEMENT OF PROBLEM The effect of gastric acid on the surface properties of denture base acrylic resin is unknown. PURPOSE The purpose of this in vitro study was to evaluate changes in the surface roughness and hardness of denture base acrylic resins after immersion in simulated gastric acid. MATERIAL AND METHODS Acrylic resin specimens (n=10) were prepared with 3 different processing techniques (compression-molded, injection-molded, and computer-aided design and computer-aided manufacturing [CAD-CAM] milled) and exposed to either gastric acid or artificial saliva (control). Surface roughness and hardness were measured at baseline (T0) and after 24-hour (T24) and 96-hour (T96) immersion in the solutions. The surface roughness and hardness data were analyzed by 3-way ANOVA and the Tukey HSD test (α=.05). RESULTS At T24, the greatest change in surface hardness was observed for compression-molded specimens in gastric acid (P<.05). At T96, changes in hardness values were higher in compression-molded specimens than those in milled specimens (P<.05). Regarding surface roughness, at T24, compression-molded and injection-molded specimens showed higher values than milled specimens in gastric acid (P<.05). Concerning specimens in artificial saliva, compression-molded specimens showed significantly higher changes in roughness than those of the others (P<.05). At T96, injection-molded specimens had the greatest roughness values (P<.05). Among specimens immersed in artificial saliva, milled specimens showed lower roughness values than the injection-molded or compression-molded specimens (P<.05). CONCLUSIONS Gastric acid exposure adversely affected the roughness and hardness of all the acrylic resins evaluated. CAD-CAM milled specimens showed better resistance to acid exposure after 24 and 96 hours in terms of roughness and hardness.
Collapse
Affiliation(s)
- Neslihan Tinastepe
- Associate Professor, Department of Prosthodontics, School of Dentistry, Uskudar University, Istanbul, Turkey.
| | - Ozlem Malkondu
- Professor, Department of Prosthodontics, School of Dentistry, Yeditepe University, Istanbul, Turkey
| | - Ender Kazazoglu
- Professor, Department of Prosthodontics, School of Dentistry, Yeditepe University, Istanbul, Turkey
| |
Collapse
|
25
|
Intaglio surface trueness of milled and 3D-printed digital maxillary and mandibular dentures: A clinical study. J Prosthet Dent 2023; 129:131-139. [PMID: 34116839 DOI: 10.1016/j.prosdent.2021.05.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 05/10/2021] [Accepted: 05/11/2021] [Indexed: 01/18/2023]
Abstract
STATEMENT OF PROBLEM While the dimensional accuracy of the intaglio surface of a removable complete denture is key to its adaptation, comfort, and clinical performance, information on the ability of milling and 3D-printing workflows to accurately reproduce this surface is lacking. PURPOSE The purpose of this clinical study was to compare the trueness of the intaglio surface of milled and 3D-printed removable complete digital dentures. MATERIAL AND METHODS Intraoral scans were obtained from 14 participants for a total of 20 edentulous arches. Ten maxillary and 10 mandibular denture bases were then designed and fabricated with a completely digital workflow, both with milling and 3D-printing. Fabricated dentures were digitized with the same intraoral scanner used to obtain intraoral digital scans of the edentulous arches. Standard tessellation language (STL) files of the printed and milled denture bases were used for 3D analysis and comparisons with the STL file of the corresponding designed denture base. Specifically, a reverse engineering software program was used to trim and extract intaglio surfaces, align them, and measure their global mean 3D distance. In order to evaluate the homogeneity of production accuracy of each manufacturing process, the intaglio surfaces were also divided into several regions of interest and the corresponding 3D distances measured. Within- and between-group differences and maxillary and mandibular dentures differences were assessed with parametric and nonparametric tests (α=.05). RESULTS Milling showed a global better trueness of the entire intaglio surface (-0.002 mm) than 3D-printing (0.018 mm), both for the whole data set (P<.001) and for maxillary (P=.032) or mandibular (P=.049) denture base subgroups. Within each fabrication technology, maxillary (P<.11) and mandibular dentures (P=.2) showed no significant difference in trueness. Measured deviations were significantly different from zero for the 3D-printed dentures (P<.001), but not for the milled dentures (P=.487). Additionally, for milled dentures, no significant difference in trueness was found among the 11 regions of interest identified for the maxillary dentures (P=.085) and the 13 regions of interest for the mandibular dentures (P=.211). Conversely, 3D-printing showed significant variations in trueness among the same zones of interest, both in maxillary (P<.001) and mandibular (P=.004) dentures. CONCLUSIONS Within the limits of the manufacturing methodologies used for complete dentures, milling can provide a slightly better trueness of the intaglio surface than 3D-printing, with less variation across several zones of interest. However, given the magnitude of such differences, they may be reasonably considered to be of limited, if any, clinical significance.
Collapse
|
26
|
AYAZ EAYDOĞAN, ALADAĞ SÜSTÜN. Effect of cigarette smoke and denture cleansers on the surface properties and color stability of CAD-CAM and conventional denture base resins. Dent Mater J 2023; 42:167-176. [PMID: 36476683 DOI: 10.4012/dmj.2022-117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
This study aimed to evaluate the hardness, roughness, and color stability of heat- and microwave-polymerized polymethyl methacrylate (PMMA), polyamide, and CAD-CAM PMMA resins when exposed to cigarette smoke (CS) and immersed in a denture cleanser (DC). Specimens of each resins were divided into four subgroups (n=10). The DC and CS+DC specimens were immersed in a DC; the CS and CS+DC specimens were exposed to CS; and the control (C) specimens were kept in distilled water. Hardness, roughness, and color measurements were performed. DC and CS significantly affected the roughness and color of all resins (p<0.05). However, these did not affect the hardness of the CAD-CAM PMMA resin (p>0.05). The CAD-CAM PMMA resin presented the lowest roughness, highest hardness, and lowest ΔE00 values. While the roughness of all resins exposed to CS when immersed in DC decreased, the ΔE00 values of the conventional PMMAs also decreased. Although this decreases were not significant, it may be advisable to use DC for smokers to decrease discoloration and roughness especially for conventional PMMAs resins.
Collapse
Affiliation(s)
- Elif AYDOĞAN AYAZ
- Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University
| | - Seda ÜSTÜN ALADAĞ
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University
| |
Collapse
|
27
|
Zeidan AAEL, Sherif AF, Baraka Y, Abualsaud R, Abdelrahim RA, Gad MM, Helal MA. Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study. J Prosthodont 2023; 32:77-82. [PMID: 35343012 DOI: 10.1111/jopr.13514] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 03/23/2022] [Indexed: 01/25/2023] Open
Abstract
PURPOSE To compare the flexural strength of computer-aided design and computer-aided manufacturing (CAD-CAM) milled denture base resin (DBR), 3D-printed DBR, polyamide, and conventional compression-molded DBR. MATERIALS AND METHODS Six denture base resins were used, one conventional heat-polymerized (Vertex), two milled CAD-CAM (AvaDent and Polident), two 3D-printed (Harz and NextDent), and one flexible polyamide (Polyamide). According to ISO 20795-1:2013, 60 specimens (65×10×3 mm) were constructed and divided into six groups (n = 10), according to DBR type. The flexural strength was measured using a universal testing machine and three-point loading test. Data were collected and analyzed using one-way ANOVA and Tukey's pair-wise post hoc tests (α = 0.05). RESULTS One-way ANOVA results showed significant differences in flexural strengths between the tested DBRs (p˂0.001). Milled denture base resins (AvaDent and Polident) had significantly higher flexural strength values than the other groups (p˂0.001) and were followed by Vertex and NextDent, while Polyamide and Harz had the lowest values. Polyamide and Harz denture base resins had significantly lower flexural strength values than conventional denture base resin (p˂0.001). CONCLUSION CAD-CAM milled DBRs showed the highest flexural strength when compared with conventional compression-molded or 3D-printed DBRs, while 3D-printed DBRs and polyamide showed the lowest flexural strengths.
Collapse
Affiliation(s)
- Ahmed Abd El-Latif Zeidan
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Badr University, Badr City, Egypt
| | - Ahmed Fadlallah Sherif
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Sinai University, North Sina, Egypt
| | - Yasser Baraka
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Sinai University, North Sina, Egypt
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ramy Abdallah Abdelrahim
- Department of Dental Biomaterials, Faculty of Dental Medicine, Al-Azhar University, Nasr City, Egypt
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohamed A Helal
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Nasr City, Egypt
| |
Collapse
|
28
|
Alaseef N, Albasarah S, Al Abdulghani H, Al-Harbi FA, Gad MM, Akhtar S, Khan SQ, Ateeq IS, Al-Qarni FD. CAD-CAM Fabricated Denture Base Resins: In Vitro Investigation of the Minimum Acceptable Denture Base Thickness. J Prosthodont 2022; 31:799-805. [PMID: 35102627 DOI: 10.1111/jopr.13486] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/25/2022] [Indexed: 01/04/2023] Open
Abstract
PURPOSE To investigate the influence of reducing material thickness on flexural properties of computer-aided design and computer-aided manufacturing (CAD-CAM) denture base resins. MATERIALS AND METHODS Four CAD-CAM denture base acrylic resin materials were selected; two were made via the subtractive method (AvaDent and IvoCad) and two were made with the additive method (FormLabs and NextDent). One heat-polymerized denture base material was used as a control. Specimens were fabricated with varying thicknesses (n = 10/group): 3.3 mm, 2.5 mm, 2 mm, or 1.5 mm. Flexural strength was evaluated via a three-point bending test. One- and two-way ANOVA were used for data analysis along with Tukey's post hoc comparison (α = 0.05). RESULTS Reducing the thickness of materials made via the subtractive method did not influence flexural strength up to 2 mm (p > 0.05). However, the difference was significant at a 1.5 mm thickness (p ˂ 0.001). For materials made via the additive method, NextDent specimens had no significant decrease in flexural strength when the thickness was reduced to 2 mm (p = 0.58). FormLabs specimens showed a significant decrease (p ˂ 0.001), although the values of flexural strength were clinically acceptable. During testing, specimens manufactured via the additive method at a 1.5 mm thickness bent without fracturing and were therefore excluded. All materials showed a reduction in elastic modulus as the thickness decreased (p ˂ 0.001). CONCLUSION Heat-polymerized, AvaDent, and IvoCad materials may be used for denture base fabrication at a minimum thickness of 1.5 mm. FormLabs and NextDent may be fabricated at a 2 mm minimum thickness, with clinically acceptable flexural properties.
Collapse
Affiliation(s)
- Nawarah Alaseef
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sara Albasarah
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hanan Al Abdulghani
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
29
|
Lee SY, Lim JH, Kim D, Lee DH, Kim SG, Kim JE. Evaluation of the color stability of 3D printed resin according to the oxygen inhibition effect and temperature difference in the post-polymerization process. J Mech Behav Biomed Mater 2022; 136:105537. [PMID: 36327665 DOI: 10.1016/j.jmbbm.2022.105537] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 10/15/2022] [Accepted: 10/19/2022] [Indexed: 11/06/2022]
Abstract
The aim of this study was to determine the color stability of 3D printed resin according to the post-curing conditions (polymerization conditions and temperature). Specimens were post-polymerized under different conditions of oxygen inhibition, such as on glycerin immersion (GLY), medium-low vacuum environment (VA), and oxygen contact (CON, the control group), and temperature (35 °C, 60 °C, and 80 °C). The degree of conversion (DC), water sorption (Wsp) and solubility (Wsl), surface roughness (Ra) were measured. Additionally, surface free energy (SFE), pH values of colorants were measured. Grape juice (grape), coffee, and curry were used as the colorants, and distilled water (DW) was used as a control. And the color value was measured before and after immersion using a spectrophotometer. Then, Calculated the color change. For statistical methods, The Shapiro-Wilk test performed to check for normality revealed that the data presented a normal distribution (p>0.05). ΔE values were analyzed using three-way ANOVA. DC, Wsp, Wsl, SFE, and Ra were analyzed using two-way ANOVA. To confirm the linear correlation, Pearson's correlation coefficient was determined. The threshold for significance (p) was set at 0.05 (95% confidence interval) for all tests. DC was the highest at 80 °C in the GLY group (95.08 ± 4.88%). And Wsl decreased with increasing temperature, and was lowest at 80 °C in the GLY group (0.46 ± 0.30 um/mm3). After the colorants were immersed for 30 days, as the temperature increased, ΔE decreased in the GLY group but not in the VA and CON groups, and was the lowest at 80 °C in the GLY group: (DW, 0.95 ± 0.45 [mean± SD]; grape, 6.45± 0.69; coffee, 4.50± 0.56; curry, 9.37± 1.40). There was also a significant inverse relation between DC and ΔE. A significant inverse relation was found between Wsl and DC, and a significant positive correlation was found between Wsl and ΔE. Wsp, SFE, and Ra did not affect color stability. In the post-polymerization process, increasing the temperature and GLY were effective in reducing ΔE, which was lowest at 80 °C in the GLY group. It was also observed that a complex mechanism between the DC, Wsl of 3D printed resin affects ΔE of the resin.
Collapse
Affiliation(s)
- Sang-Yub Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Department of Prosthodontics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jung-Hwa Lim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Dohyun Kim
- Department of Conservative Dentistry, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Dong-Hwan Lee
- Department of Prosthodontics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Seok Gyu Kim
- Department of Prosthodontics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
30
|
Gibreel M, Perea-Lowery L, Lassila L, Vallittu PK. Mechanical Properties Evaluation of Three Different Materials for Implant Supported Overdenture: An In-Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6858. [PMID: 36234196 PMCID: PMC9572462 DOI: 10.3390/ma15196858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 09/07/2022] [Accepted: 09/29/2022] [Indexed: 06/16/2023]
Abstract
Aim: the aim of this study was to compare the flexural strength and elastic modulus of three-dimensionally (3D) printed, conventional heat-cured, and high-impact implant-supported overdenture materials specimens. Materials and Methods: Thirty implant-supported overdenture materials specimens (bar-shaped, 65.0 × 10.2 × 5.1 ± 0.2 mm3) with one central hole were fabricated using 3D-printed, heat-cured conventional, and high-impact denture base resins (n = 10/group). Autopolymerizing acrylic resin was used to attach titanium matrix housings to the central holes of the specimens. A three-point bending test was conducted using a universal testing machine and a model analog with a crosshead speed of 5 mm/min. The indicative flexural strength and elastic modulus were recorded. Data were statistically analyzed using analysis of variance (ANOVA) and the Tukey tests at α = 0.05. Results: One-way ANOVA revealed a significant effect of denture base material on the flexural strength (p < 0.001) but not on the elastic modulus (p = 0.451) of the evaluated materials. The flexural strength of the 3D-printed specimens (95.99 ± 9.87 MPa) was significantly higher than the conventional (77.18 ± 9.69 MPa; p < 0.001) and high-impact ones (82.74 ± 7.73 MPa; p = 0.002). Conclusions: The maximum flexural strength was observed in the 3D-printed implant-supported overdenture material specimens, which might indicate their suitability as an alternative to the conventionally fabricated ones. Flexural strength and elastic modulus of conventional and high-impact heat-cured implant-supported overdenture materials specimens were comparable.
Collapse
Affiliation(s)
- Mona Gibreel
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland
| | - Leila Perea-Lowery
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland
| | - Pekka K. Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, 20520 Turku, Finland
- City of Turku Welfare Division, Oral Health Care, Puolalankatu 5, 20101 Turku, Finland
| |
Collapse
|
31
|
Park SJ, Lee JS. Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base. J Adv Prosthodont 2022; 14:262-272. [PMID: 36105879 PMCID: PMC9444486 DOI: 10.4047/jap.2022.14.4.262] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Revised: 07/11/2022] [Accepted: 08/22/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey’s honest significant difference test was used for post-hoc analysis (P < .05). RESULTS Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.
Collapse
Affiliation(s)
- Se-Jick Park
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Joon-Seok Lee
- Department of Prosthodontics, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| |
Collapse
|
32
|
Alzaid M, AlToraibily F, Al-Qarni FD, Al-Thobity AM, Akhtar S, Ali S, Al-Harbi FA, Gad MM. The Effect of Salivary pH on the Flexural Strength and Surface Properties of CAD/CAM Denture Base Materials. Eur J Dent 2022; 17:234-241. [PMID: 35820440 PMCID: PMC9949971 DOI: 10.1055/s-0042-1749160] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
OBJECTIVES This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins. METHODS One heat-polymerized, two CAD/CAM milled (IvoCad, AvaDent), and two 3D-printed (FormLabs, NextDent) denture base resins were fabricated and divided into five groups (n = 10) according to the solutions: three groups were immersed in different salivary pH (5.7, 7.0, or 8.3), one group was immersed in distilled water (DW) as a positive control, and one group had no immersion (negative control). All immersions were performed at 37°C for 90 days. Flexural strength, hardness, and surface roughness were measured before and after immersion. Data was analyzed with analysis of variance and post hoc Tukey's test (α = 0.05). RESULTS After immersion, all specimens had lower flexural strength values when compared with those with no immersion. Comparing the immersion groups, the highest flexural strength value (93.96 ± 3.18 MPa) was recorded with IvoCad after immersion in DW while the lowest value (60.43 ± 2.66 MPa) was recorded with NextDent after being immersed in 7.0 pH saliva. All specimens had significant decrease in hardness except IvoCad and AvaDent specimens where both presented the highest surface hardness (53.76 ± 1.60 Vickers hardness number [VHN]) after immersion in DW while NextDent showed the lowest hardness value (24.91 ± 2.13 VHN) after being immersed in 8.3 pH saliva. There was statistically significant difference between the baseline and different artificial salivary pH solutions in terms of surfaces roughness, with the highest surface roughness were found in 3D-printed resin materials. CONCLUSION After exposure to artificial saliva with different salivary pH, the milled CAD/CAM denture base resins showed higher flexural strength, hardness, and lesser surface roughness than conventional and 3D-printed denture base resins.
Collapse
Affiliation(s)
- Maryam Alzaid
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fatemah AlToraibily
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D. Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M. Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Saqib Ali
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia,Address for correspondence Mohammed M. Gad, BDS, MSc Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal UniversityDammam 31441Kingdom of Saudi Arabia
| |
Collapse
|
33
|
Costa V, Silva AS, Costa R, Barreiros P, Mendes J, Mendes JM. In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses. Dent J (Basel) 2022; 10:dj10060112. [PMID: 35735654 PMCID: PMC9221835 DOI: 10.3390/dj10060112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 05/31/2022] [Accepted: 06/08/2022] [Indexed: 12/10/2022] Open
Abstract
With continuing technological developments, there have been advances in the field of fixed prosthetics, particularly in impression-taking techniques. These technological advances mean that a wide variety of diagnostic and/or rehabilitation possibilities can be explored without the need for physical models. The aim of this study was to evaluate the accuracy of three intraoral scanners used in oral implant rehabilitation using an extraoral scanner as a reference and varying the scanning area. Three models representing different clinical scenarios were scanned 15 times by each intraoral scanner and three times by the extraoral scanner. The readings were analyzed and overlaid using engineering software (Geomagic® Control X software (Artec Europe, Luxembourg)). Statistically significant differences in accuracy were found between the three intraoral scanners, iTero® (Align Technology Inc., San Jose, CA, USA), Medit® (Medit®: Seoul, Korea), and Planmeca® (Planmeca®: Helsinki, Finland). In all clinical scenarios, the iTero® scanner had the best trueness (24.4 μm), followed by the Medit® (26.4 μm) and Planmeca® (42.1 μm). The Medit® showed the best precision (18.00 μm) followed by the iTero® (19.20 μm) and Planmeca® (34.30 μm). We concluded that the iTero® scanner had the highest reproducibility and accuracy in the clinical setting.
Collapse
Affiliation(s)
- Vitória Costa
- Department of Dental Sciences, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal; (V.C.); (R.C.)
| | - António Sérgio Silva
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal; (P.B.); (J.M.); (J.M.M.)
- Correspondence:
| | - Rosana Costa
- Department of Dental Sciences, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal; (V.C.); (R.C.)
| | - Pedro Barreiros
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal; (P.B.); (J.M.); (J.M.M.)
| | - Joana Mendes
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal; (P.B.); (J.M.); (J.M.M.)
| | - José Manuel Mendes
- UNIPRO—Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal; (P.B.); (J.M.); (J.M.M.)
| |
Collapse
|
34
|
Freitas RFCPD, Duarte S, Feitosa S, Dutra V, Lin WS, Panariello BHD, Carreiro ADFP. Physical, mechanical and anti-biofilm formation properties of CAD-CAM milled or 3D printed denture base resins: In Vitro analysis. J Prosthodont 2022; 32:38-44. [PMID: 35661475 DOI: 10.1111/jopr.13554] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 05/29/2022] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To investigate surface characteristics (roughness and contact angle), anti-biofilm formation, and mechanical properties (mini-flexural strength) of computer-aided design and computer-aided manufacturing (CAD-CAM) PMMA polymer, and three-dimensional (3D) printed resin for denture base fabrication compared with conventional heat polymerized denture base resins. MATERIALS AND METHODS A total of 60 discs and 40 rectangular specimens were fabricated from one CAD-CAM (AvaDent), one 3D printed (Cosmos Denture), and two conventional heat polymerized (Lucitone 199 and VipiWave) materials for denture base fabrication. Roughness was determined by Ra value; the contact angle was measured by the sessile drop method; the biofilm formation inhibition behavior was analyzed through C. albicans adhesion, while mini-flexural strength test was done using a three-point bending test. The data were analyzed using descriptive and analytical statistics (α = 0.05). RESULTS The CAD-CAM PMMA group showed the lowest C. albicans adhesion (log CFU/mL: 3.74 ±0.57) and highest mini-flexural strength mean (114.96 ±16.23 MPa). 3D printed specimens presented the highest surface roughness (Ra: 0.317 ±0.151 μm) and lowest mini-flexural strength values (57.23 ±9.07 MPa). However, there was no statistical difference between CAD-CAM PMMA and conventional groups for roughness, contact angle, and mini-flexural strength. CONCLUSIONS CAD-CAM milled materials present surface and mechanical properties similar to conventional resins and show improved behavior preventing C. albicans adhesion. Nevertheless, 3D printed resins present decreased mini-flexural strength. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | - Simone Duarte
- Department of Cariology, Operative Dentistry and Dental Public Health, Indiana University School of Dentistry, Indianapolis, IN
| | - Sabrina Feitosa
- Department of Biomedical Sciences and Comprehensive Care, Division of Biomedical and Applied Sciences, Indiana University School of Dentistry, Indianapolis, IN
| | - Vinicius Dutra
- Department of Oral Pathology, Medicine and Radiology, Indiana University School of Dentistry, Indianapolis, IN
| | - Wei-Shao Lin
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN
| | - Beatriz Helena Dias Panariello
- Department of Cariology, Operative Dentistry and Dental Public Health, Indiana University School of Dentistry, Indianapolis, IN
| | | |
Collapse
|
35
|
Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review. MATERIALS 2022; 15:ma15113868. [PMID: 35683165 PMCID: PMC9182039 DOI: 10.3390/ma15113868] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/23/2022] [Accepted: 05/25/2022] [Indexed: 02/01/2023]
Abstract
CAD/CAM technology is gaining popularity and replacing archaic conventional procedures for fabricating dentures. CAD/CAM supports using a digital workflow reduce the number of visits, chair time, and laboratory time, making it attractive to patients. This study aimed to provide a comparative review of complete dentures manufactured using CAD/CAM and conventional methods. The PubMed/Medline, Science Direct, Cochrane, and Google Scholar databases were searched for studies published in English within the last 11 years (from 2011 to 2021). The keywords used were “computer-engineered complete dentures”, “CAD/CAM complete dentures”, “computer-aided engineering complete dentures”, and “digital complete dentures”. The search yielded 102 articles. Eighteen relevant articles were included in this review. Overall, computer-engineered complete dentures have several advantages over conventional dentures. Patients reported greater satisfaction with computer-engineered complete dentures (CECDs) due to better fit, reduced chair time, shorter appointments, and fewer post-insertion visits. CAD/CAM allows for precision and reproducibility with fewer procedures compared to conventional dentures. Polymethyl methacrylate is used as the denture base material for conventional dentures. For CECDs, the resin can be modified and cross-linked to improve its mechanical properties. The advantages of CECDs include a reduced number of appointments, saving chairside time, a digital workflow allowing easy reproducibility and greater patient satisfaction with a better fit.
Collapse
|
36
|
Fouda SM, Gad MM, Abualsaud R, Ellakany P, AlRumaih HS, Khan SQ, Akhtar S, Al-Qarni FD, Al-Harbi FA. Flexural Properties and Hardness of CAD-CAM Denture Base Materials. J Prosthodont 2022; 32:318-324. [PMID: 35567362 DOI: 10.1111/jopr.13535] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 05/02/2022] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To compare flexural strength, elastic modulus, and surface hardness of CAD-CAM milled, 3D-printed, and heat-polymerized denture base resins. MATERIALS AND METHODS A total of 120 specimens were fabricated from heat-polymerized acrylic resin (HP), milled resin (Avadent and IvoCad), and 3D-printed resin (ASIGA, FormLabs, and NextDent). The specimens were divided into 6 groups according to the type of denture base material n = 20/material, (10/flexural properties and 10/hardness). Flexural strength and elastic modulus of the specimens were evaluated by 3-point bending test and surface hardness by Vickers hardness test. To test flexural properties, the specimens were fabricated according to ISO 20795-1:2013 standards (64×10×3.3 ±0.2 mm). The dimensions for hardness test were 15×10×2.5 ±0.2 mm. Scanning electron microscope was used to evaluate the surface morphology of the fractured specimens. The means and standard deviations were calculated, followed by one-way ANOVA and Tukey post-hoc test (α = 0.05). RESULTS Milled resins showed significantly higher values for flexural strength, elastic modulus, and surface hardness, followed by HP then 3D-printed resins (P<0.001). In between milled groups, flexural strength of AvaDent was significantly higher than IvoCad (P<0.001), while elastic modulus and hardness didn't show significant difference. In between 3D-printed resins, ASIGA showed the highest flexural strength and elastic modulus, insignificantly with FormLabs (P = 0.595) and significantly with NextDent (P = 0.008). ASIGA also showed significantly the highest hardness among the 3D-printed groups. No significant difference was found between FormLabs and NextDent flexural strength (P = 0.357), elastic modulus (P = 1.00) and surface hardness (P = 0.987). CONCLUSION CAD-CAM milled resins had greater flexural properties and hardness compared to heat-polymerized acrylic resin and 3D-printed resins. Although 3D-printed samples showed the lowest values of tested properties, the flexural strength and modulus were above the clinically acceptable values. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hamad S AlRumaih
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Clinical Affairs, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal D Al-Qarni
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
37
|
Helal MA, Abd Elrahim RA, El-Latif Zeidan AA. Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study. J Prosthodont 2022; 32:11-19. [PMID: 35524633 DOI: 10.1111/jopr.13538] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 04/28/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE This study compared the dimensional changes between the computer-aided design and computer-aided manufacturing (CAD-CAM) milled complete denture bases (CDBs) and three-dimensional (3D) printed CDBs. MATERIALS AND METHODS One maxillary completely edentulous stone model was fabricated with three reference points at the incisive papilla, right molar, and left molar areas marked as X, Y, and Z, respectively. It was scanned to produce a standard tessellation language (STL) file, which was imported to a metal milling machine software to produce the metal model. This metal model was used to fabricate 30 CDBs for analysis in this study. The CDBs were divided into three groups (n = 10 each) according to the fabrication method used as follows: Group 1, CAD-CAM milled CDBs; Group 2, 3D printed CDBs; and Group 3, conventional compression molded CDBs. The CDBs of all groups were scanned after fabrication, and the dimensional changes in each were evaluated by two methods. The first was the two-dimensional evaluation method that involved linear measurement of the distances between the reference points (X-Y, X-Z, and Y-Z) of the scanned reference cast and dentures. The second method was the 3D evaluation method that involved the superimposition of the STL files of the dentures on the STL file of the reference cast. Data were calculated and were statistically analyzed using one-way analysis of variance and Tukey's pairwise post hoc tests. RESULTS There was a significant difference in the dimensional accuracy between the CAD-CAM milled, 3D printed, and conventional compression molded CDBs (P<0.05). CONCLUSION The dimensional accuracy of the CAD-CAM milling system in complete denture fabrication is superior to that of the compression molding and 3D printing systems. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Mohamed Ahmed Helal
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt
| | | | | |
Collapse
|
38
|
Special Issue on Current Techniques and Materials in Dentistry. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
In the field of dentistry, the use of regenerative therapy, as well as biocompatible and biomimetic materials, is well-established [...]
Collapse
|
39
|
Current Implementation of Digital Dentistry for Removable Prosthodontics in US Dental Schools. Int J Dent 2022; 2022:7331185. [PMID: 35464101 PMCID: PMC9033361 DOI: 10.1155/2022/7331185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 03/18/2022] [Accepted: 03/30/2022] [Indexed: 12/03/2022] Open
Abstract
Objectives Although digital technology has been widely integrated into dental education, there is limited literature investigating the extent of the integration of computer-aided design and computer-aided manufacturing (CAD-CAM) for removable systems in the dental curriculum. The purpose of this study was to assess the current implementation of CAD-CAM complete and partial dentures in predoctoral (PP) and advanced graduate prosthodontic (AGP) education in US dental schools. The study also aimed to identify potential barriers to its implementation in the dental curriculum. Methods An online survey with 15 questions was created using online survey software. The survey was distributed to the directors of predoctoral prosthodontics in 56 schools and advanced graduate programs of prosthodontics in 52 schools listed in the 2018–19 American Dental Education Association (ADEA) Directory. Results The percentage of programs (PP and AGP) implementing CAD-CAM complete dentures (CAD-CAM CDs) and CAD-CAM removable partial dentures (CAD-CAM RPDs) in their didactic, preclinical, and clinical curricula was recorded. CAD-CAM CDs are taught in didactic courses in 54.2% of PP and 65.2% of AGP. However, CAD-CAM RPDs are only taught in 37.5% of PP and 47.8% of AGP. Programs are largely limited by a lack of funds, resources, time, and faculty members. Conclusion While digital technologies have indeed become more prevalent in dental education, many institutions face barriers to implementation. More research must be conducted in order to support the continued incorporation of digital technologies into dental education.
Collapse
|
40
|
Is the Number of Appointments for Complete Denture Fabrication Reduced with CAD-CAM? A Literature Review. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4010010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
One of the key arguments in favor of digitally produced complete dentures (CDs) is the requirement for less patient visits in comparison to the conventional workflow. However, it is not yet clear if this argument is accurate; nor, if indeed the insertion of the complete dentures is achieved in fewer appointments, how many are required. The purpose of this literature review was to investigate the reported number of required patient visits for the production of digitally fabricated CDs. An electronic search was performed in PubMed/MEDLINE using three groups of keywords: “complete dentures”, “CAD/CAM”, and “Appointments” with their alternative forms. Out of the initial 157 results, 36 articles were automatically selected utilizing exclusion keywords. After consensus between the two examiners, eight articles were finally analyzed and presented in a table. The majority (75%) of the reports came from institutions, and the average number of appointments up to complete denture insertion was 4.1, not always including try-in dentures. In this study, it can be concluded that, with a digital workflow, the insertion appointment is reached in fewer visits than the conventional five-visit procedure which is commonly taught in dental schools.
Collapse
|
41
|
Lee EH, Ahn JS, Lim YJ, Kwon HB, Kim MJ. Effect of layer thickness and printing orientation on the color stability and stainability of a 3D-printed resin material. J Prosthet Dent 2022; 127:784.e1-784.e7. [DOI: 10.1016/j.prosdent.2022.01.024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 01/21/2022] [Accepted: 01/21/2022] [Indexed: 12/21/2022]
|
42
|
Ohara K, Isshiki Y, Hoshi N, Ohno A, Kawanishi N, Nagashima S, Inoue M, Kubo D, Yamaya K, Inoue E, Kimoto K. Patient satisfaction with conventional dentures vs. digital dentures fabricated using 3D-printing: A randomized crossover trial. J Prosthodont Res 2022; 66:623-629. [PMID: 35082225 DOI: 10.2186/jpr.jpr_d_21_00048] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE Evidence regarding the performance of digital dentures (DDs) fabricated using 3D printing is insufficient. This study aimed to evaluate patient satisfaction with conventional dentures (CDs) and DDs fabricated using 3D printing. METHODS This randomized controlled trial was conducted between November 2017 and May 2020. In the CD-DD group, CDs were fabricated before DDs, while the protocol was reversed in the DD-CD group. The primary outcome was patient satisfaction, quantified using a 100-mm visual analog scale, which assessed chewing efficiency, pain, stability, retention, comfort, esthetics, ease of cleaning, phonetics, and general satisfaction. Secondary outcomes were quality of life (QOL), number of visits, time required for definitive denture fabrication, number of adjustment appointments, and time required for denture stabilization after denture delivery. RESULTS Patient satisfaction with CDs was superior in terms of phonetics, ease of cleaning, stability, comfort, and general satisfaction. Secondary outcomes such as social disability and the number of clinic visits were significantly lower in patients with DDs. However, the two groups showed no significant differences in the other outcomes. Although patient satisfaction with DDs was inferior to that with CDs, 20% of patients preferred and used DDs (12 patients preferred CDs, and three patients opted for DDs). CONCLUSION Although patient satisfaction or QOL with DDs may be somewhat inferior to that with CDs, 20% of patients preferred and used DDs daily. Thus, DDs fabricated using 3D printing may have comparable practicality and efficacy to CDs.
Collapse
Affiliation(s)
- Katsura Ohara
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Yukari Isshiki
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Noriyuki Hoshi
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Akinori Ohno
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Norishige Kawanishi
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Shintaro Nagashima
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Makoto Inoue
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Daijiro Kubo
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| | - Katsuhiko Yamaya
- Technical Department of Kanagawa Dental University Hospital, Kanagawa, Japan
| | - Erika Inoue
- Technical Department of Kanagawa Dental University Hospital, Kanagawa, Japan
| | - Katsuhiko Kimoto
- Department of Oral Interdisciplinary Medicine (Prosthodontics & Oral Implantology), Graduate School of Dentistry, Kanagawa Dental University, Kanagawa, Japan
| |
Collapse
|
43
|
Abualsaud R, Gad M. Flexural strength of CAD/CAM denture base materials: Systematic review and meta-analysis of in-vitro studies. J Int Soc Prev Community Dent 2022; 12:160-170. [PMID: 35462750 PMCID: PMC9022382 DOI: 10.4103/jispcd.jispcd_310_21] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/11/2021] [Accepted: 12/22/2021] [Indexed: 11/25/2022] Open
Abstract
Introduction: Digital complete dentures fabrication techniques are expanding. This study aimed to review flexural strength (FS) of milled and 3D-printed denture base materials to answer the study question: is FS of computer-aided designing/computer-aided manufacturing (CAD/CAM) denture base comparable to conventional heat-polymerized materials? Materials and Methods: Search was done within different databases for articles published between January 2010 and June 2021 using specific keywords. Articles of in-vitro studies in English language with methods following International Standards Organization standardization/ADA specifications for flexural testing of conventional and CAD/CAM (milled or printed) polymethyl methacrylate (PMMA) materials were included. Results: Out of the 61 studies, 9 were processed for data extraction and only 7 underwent meta-analysis. Two, six, and one study showed high, moderate, and low risk of bias, respectively. Random-effects model was used for analysis and resulted in the average FS of 120.61 MPa [95% confidence interval (CI): 109.81−131.41] and 92.16 MPa (CI: 75.12−109.19) for CAD/CAM milled and heat-polymerized PMMA, respectively. Conclusion: Subtractive CAD/CAM technique of denture fabrication showed satisfactory FS values, whereas additive CAD/CAM method was comparable to conventional heat-polymerized technique with lower value, requiring further investigations and improvement. The clinical use of milled denture bases is an acceptable substitution to heat-polymerized PMMA, making the denture fabrication an easier and faster process.
Collapse
|
44
|
Özatik Ş, Saygılı S, Sülün T, Alan CB. Semi-Digital Workflow of Removable Partial Denture Fabrication for Scleroderma-Induced Microstomia Patients: Two Clinical Reports. ANNALS OF DENTAL SPECIALTY 2022. [DOI: 10.51847/cf2jbpvhvl] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
45
|
Tieh MT, Waddell JN, Choi JJE. Optical and mechanical properties of conventional, milled and 3D-printed denture teeth. J Mech Behav Biomed Mater 2021; 126:105061. [PMID: 34963102 DOI: 10.1016/j.jmbbm.2021.105061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 12/14/2021] [Accepted: 12/20/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Investigate the effect of various liquids on the optical properties and Vickers hardness of conventional, milled and 3D-printed denture teeth. METHODS Six different types of denture teeth (Maxillary anteriors of three different conventional teeth, Vivodent DCL, SR Phonares II, Vita Physiodens; milled teeth, IvotionDent; and two different 3D-printed teeth, Asiga DentaTooth and NextDent C&B MFH) were investigated (total n = 336). The labial surface of each specimen was prepared to a dimension of 10 × 5 × 3mm. Specimens were immersed in artificial saliva, coffee, red wine and denture cleaner with artificial aging to simulate denture use of 12 and 24 months in vivo. Measurements of translucency parameter (TP), shade change (ΔE), surface roughness (Ra) and Vickers hardness (VHN) were conducted at baseline and after artificial aging while immersed in the liquids at each timeframe. Data were statistically analysed by ANOVA and post-hoc test (SPSS Ver 27). Surfaces of specimens were analysed under scanning electron microscopy (SEM). RESULTS Milled teeth had the highest overall translucency parameter (5.33 ± 0.76-7.3 ± 0.99). All materials had statistically significant change in translucency parameter and shade after 24 months simulated aging (p < 0.05), especially the milled and 3D-printed teeth (p < 0.01). Surface roughness of all materials were under plaque accumulation threshold Ra = 0.2 μm. At baseline, Vita Physiodens teeth (PMMA with microfillers) demonstrated the highest hardness (33.99 kgf/mm2±3.7), whereas both 3D-printed materials exhibited the lowest hardness (13.27 kgf/mm2±0.36-18.13 kgf/mm2±0.93). Artificial saliva, red wine and denture cleaner had a statistically significant impact (p < 0.05) on hardness of all materials (12.1 kgf/mm2±1.17-30.77 kgf/mm2±2.98). CONCLUSIONS Milled teeth exhibited the best optical properties (highest overall translucency parameter and lowest shade change). Milled teeth were also the only material that showed colour change (ΔE values) within clinically acceptable limits. Denture cleaner had the most impact on optical and mechanical properties of all materials. Surface roughness and hardness of 3D-printed teeth had the most change after artificial aging.
Collapse
Affiliation(s)
- Mei Ting Tieh
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - John Neil Waddell
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand
| | - Joanne Jung Eun Choi
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, 310 Great King Street, Dunedin, 9016, New Zealand.
| |
Collapse
|
46
|
Accuracy of trial complete dentures fabricated by using fused deposition modeling 3-dimensional printing: An in vitro study. J Prosthet Dent 2021:S0022-3913(21)00416-9. [PMID: 34509288 DOI: 10.1016/j.prosdent.2021.07.021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 07/13/2021] [Accepted: 07/14/2021] [Indexed: 10/20/2022]
Abstract
STATEMENT OF PROBLEM Three-dimensional (3D) printing technologies commonly used for trial complete dentures use photopolymerizing resins. Although effective, some clinical, process-related, and practical issues associated with them are still unclear. The option of using alternative printing technologies may help in overcoming limitations. PURPOSE The purpose of this in vitro study was to evaluate the trueness of trial dentures fabricated by using 3D-printing fused deposition modeling (FDM). MATERIAL AND METHODS Ten maxillary and 10 mandibular digital complete trial dentures designed from intraoral scans were fabricated from polylactic acid by using a FDM 3D-printer. Each denture was scanned, and the scans were compared with the digital file of the designed denture by means of a surface-matching software program. The mean distance (both signed and absolute) was measured and recorded for the intaglio surface, as well as for the entire denture surface. Statistical analysis was performed to investigate the significance of the extent of measured distances, as well as differences between intaglio and global deviations; subgroup analysis for arch type was also performed (α=.05). RESULTS Mean values of the intaglio distance were not significantly different from zero (P=.223). The manufacturing accuracy of the intaglio surface was higher than that measured for the entire denture (P<.001), confirmed both by the averaged signed (0 mm and -0.028 mm, respectively) and the absolute mean deviations (0.06 mm and 0.08 mm, respectively). No significant differences were found between maxillary and mandibular trial dentures. CONCLUSIONS 3D-printing may constitute a valid and practical option for accurate and affordable digital trial dentures.
Collapse
|
47
|
Abstract
Fabrication of complete dentures (CDs) utilizing computer-aided design and computer-aided manufacturing (CAD/CAM) methods has attracted a lot of attention. The purpose of this paper was to summarize current knowledge about digital CDs and the relevant technology, and to present the application of the new technology in a dental geriatrics case. Initially, some of the challenges regarding digitization of the oral mucosa as a supporting surface of the CDs’ intaglio surface are listed. Next, a brief introduction of the CAD software capabilities regarding CDs is presented. The latest CAM additive and subtractive techniques for CDs are following. Subsequently, the consecutive steps for the construction of a digital CD as part of the prosthodontic treatment of a 90-year-old ambulative female patient are presented. Finally, some considerations about the digital workflow in CD manufacturing are discussed. In conclusion, the new digital technology has clear advantages; however, implementation requires careful planning. The digital workflow is applicable and versatile.
Collapse
|
48
|
Helal MA, Al-Gazzar AE, Abas M, Akhtar S, Gad MM, Al-Thobity AM. Comparative Effect of Different Surface Treatments on the Shear Bond Strength of Two Types of Artificial Teeth Bonded To Two Types of Denture Base Resins. J Prosthodont 2021; 31:427-433. [PMID: 34480386 DOI: 10.1111/jopr.13425] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/30/2021] [Indexed: 11/26/2022] Open
Abstract
PURPOSE This in vitro study aims to assess the impact of various surface treatments on the shear bond strength (SBS) of two types of artificial teeth and denture base resins (DBRs). MATERIALS AND METHODS Two types of DBRs (CAD/CAM-milled and heat-polymerized) and two types of denture teeth (acrylic and composite) were investigated. Teeth were cut into slices (5 × 5 × 2 mm) and divided according to surface treatment into four subgroups (n = 10): no treatment (control), air abrasion (Alumina-blasting; AB), bur roughening, and dichloromethane (DCM) subgroups. According to manufacturer recommendations, the treated tooth slices were bonded to the acrylic disk of DBRs. The SBS test was performed using a universal testing machine. ANOVA was used for results analysis followed by Tukey's post hoc tests (α = 0.05). RESULTS DCM and AB increased the SBS of acrylic teeth to heat-polymerized DBR compared with other groups (p < 0.001). All surface treatments showed no significant difference in CAD/CAM DBR with acrylic teeth (p = 0.059; AB, p = 0.319; bur roughening, p = 0.895; DCM), while there was a significant decrease in SBS with composite teeth (p ˂ 0.001). Between teeth, acrylic teeth showed a statistically significant increase in SBS compared to composite teeth (p < 0.001). CONCLUSION AB and DCM application improved the SBS for acrylic teeth with the heat-polymerized DBR when compared with the untreated group, but none of the surface treatment agents showed significant improvement with CAD/CAM DBR. All surface treatment agents reduced the SBS for composite teeth with CAD/CAM DBR while AB only increased the SBS with heat-polymerized DBR.
Collapse
Affiliation(s)
- Mohamed A Helal
- Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt
| | | | - Mohamed Abas
- Department of Dental Biomaterials, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
49
|
Gad MM, Fouda SM, Abualsaud R, Alshahrani FA, Al-Thobity AM, Khan SQ, Akhtar S, Ateeq IS, Helal MA, Al-Harbi FA. Strength and Surface Properties of a 3D-Printed Denture Base Polymer. J Prosthodont 2021; 31:412-418. [PMID: 34347351 DOI: 10.1111/jopr.13413] [Citation(s) in RCA: 72] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This in vitro study evaluated the flexural strength, impact strength, hardness, and surface roughness of 3D-printed denture base resin subjected to thermal cycling treatment. MATERIALS AND METHODS According to ISO 20795-1:2013 standards, 120 acrylic resin specimens (40/flexural strength test, 40/impact strength, and 40/surface roughness and hardness test, n = 10) were fabricated and distributed into two groups: heat-polymerized; (Major.Base.20) as control and 3D-printed (NextDent) as experimental group. Half of the specimens of each group were subjected to 10,000 thermal cycles of 5 to 55°C simulating 1 year of clinical use. Flexural strength (MPa), impact strength (KJ/m2 ), hardness (VHN), and surface roughness (μm) were measured using universal testing machine, Charpy's impact tester, Vickers hardness tester, and profilometer, respectively. Data were analyzed by ANOVA and Tukey honestly significant difference (HSD) test (α = 0.05). RESULTS The values of flexural strength (MPa) were 86.63 ± 1.0 and 69.15 ± 0.88; impact strength (KJ/m2 )-6.32 ± 0.50 and 2.44 ± 0.31; hardness (VHN)-41.63 ± 2.03 and 34.62 ± 2.1; and surface roughness (μm)-0.18 ± 0.01 and 0.12 ± 0.02 for heat-polymerized and 3D-printed denture base materials, respectively. Significant differences in all tested properties were recorded between heat-polymerized and 3D-printed denture base materials (P < 0.001). Thermal cycling significantly lowered the flexural strength (63.93 ± 1.54 MPa), impact strength (2.40 ± 0.35 KJ/m2 ), and hardness (30.17 ± 1.38 VHN) of 3D-printed resin in comparison to thermal cycled heat-polymerized resin, but surface roughness showed non-significant difference (p = 0.262). CONCLUSION 3D-printed resin had inferior flexural strength, impact strength, and hardness values than heat-polymerized resin, but showed superior surface roughness. Temperature changes (thermal cycling) significantly reduced the hardness and flexural strength and increased surface roughness, but did not affect the impact strength.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faris A Alshahrani
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohamed A Helal
- Department of Removable Prosthodontics, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
50
|
Chappuis Chocano AP, Venante HS, Bringel da Costa RM, Pordeus MD, Santiago Junior JF, Porto VC. Evaluation of the clinical performance of dentures manufactured by computer-aided technology and conventional techniques: A systematic review. J Prosthet Dent 2021; 129:547-553. [PMID: 34332774 DOI: 10.1016/j.prosdent.2021.06.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM The introduction of computer-aided design and computer-aided manufacturing (CAD-CAM) technology for complete denture fabrication may have improved clinical outcomes compared with conventional techniques. However, systematic reviews comparing these techniques are lacking. PURPOSE The purpose of this systematic review was to identify, compare, and synthesize the outcomes of published clinical studies related to complete denture fabrication, with respect to the differences between CAD-CAM technology and conventional techniques. MATERIAL AND METHODS A comprehensive search of studies published up to March 16, 2020, was conducted by using the PubMed/MEDLINE, Web of Science, Cochrane Library, SciELO, and Embase databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement criteria and was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID 42020202614). The population, intervention, comparison, and outcome (PICO) question was: Do CAD-CAM complete dentures have a similar functional performance to those fabricated by conventional techniques? The quality of publications was appraised by using the Critical Appraisal Skills Program (CASP) checklists. RESULTS Of the 1232 titles, 6 articles were selected. The studies reported better retention of digitally manufactured complete dentures without denture adhesives than that of conventional complete dentures with or without denture adhesives. Other studies reported that dentures manufactured with digital systems were better adapted to tissue surfaces, required less clinical time, were lower in cost, and provided better experience and satisfaction to patients. CONCLUSIONS The assessment of CAD-CAM planning and manufacturing through clinical studies is ongoing. However, preliminary results indicate better clinical performance and lower overall costs of digital complete dentures than conventional dentures.
Collapse
Affiliation(s)
- Ana Paula Chappuis Chocano
- PhD student, Department of Periodontics and Prosthodontics, Dental School of Bauru, FOB-USP, University of São Paulo, Bauru, São Paulo, Brazil
| | - Helena Sandrini Venante
- PhD student, Department of Periodontics and Prosthodontics, Dental School of Bauru, FOB-USP, University of São Paulo, Bauru, São Paulo, Brazil.
| | - Rodrigo Moreira Bringel da Costa
- PhD student, Department of Periodontics and Prosthodontics, Dental School of Bauru, FOB-USP, University of São Paulo, Bauru, São Paulo, Brazil
| | - Mariana Domingues Pordeus
- PhD student, Department of Periodontics and Prosthodontics, Dental School of Bauru, FOB-USP, University of São Paulo, Bauru, São Paulo, Brazil
| | | | - Vinicius Carvalho Porto
- Professor, Department of Periodontics and Prosthodontics, Dental School of Bauru, FOB-USP, University of São Paulo, Bauru, São Paulo, Brazil
| |
Collapse
|