1
|
Huraib WM, Pullishery F, Al-Ghalib TA, Niyazi AAT, Binhuraib H, El Homossany M, Bamigdad MS. Influence of rough micro-threaded and laser micro-textured implant-neck on peri-implant tissues: A systematic review. Saudi Dent J 2023; 35:602-613. [PMID: 37817785 PMCID: PMC10562115 DOI: 10.1016/j.sdentj.2023.05.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 05/25/2023] [Accepted: 05/28/2023] [Indexed: 10/12/2023] Open
Abstract
Background and objective This systematic review aimed to explore clinical outcomes of marginal or crestal bone level (MBL) and soft tissue status around implants, following the placement of rough micro-threaded/laser-microtextured surface (LMS) implants. These outcomes are compared with those following the placement of smooth machined-neck implants. Materials and methods Using EBSCO Information Services, we conducted a web-based search of databases such as the PubMed, Scopus, and EMBASE, for relevant English-language scientific papers published between January 2013 and August 2022. Prospective or retrospective controlled cohort studies and randomized controlled trials (RCTs) investigating the role of rough micro-threaded/LMS implant necks on MBL, sulcular probing depth (PD), and/or clinical attachment loss, were included in this review. Results From a comprehensive literature search of 247 articles, 6 RCTs, 5 prospective studies, and 4 retrospective studies (n = 15) fulfilled the eligibility criteria. MBL with rough micro-threaded implant necks ranged from 0.12 ± 0.17 mm to 3.25 ± 0.4 mm after loading. The smooth machined-neck implants without a micro-threaded neck had a loading MBL of 0.38 ± 0.51 mm to 3.75 ± 0.4 mm. Micro-threaded implant necks showed much lower MBL than machined-neck implants. LMS implant necks had a lower peri-implant PD than machined-neck implants after 3 years of early loading (2.3 ± 0.7 mm vs. 3.8 ± 0.8 mm). The experimental and control groups showed similar gingival recessions (1.08 ± 0.4 mm vs. 2.46 ± 0.3 mm). Meta-analysis was not feasible owing to heterogeneity of the studies. Conclusion Under functional loading, a roughened micro-threaded design for the implant neck could significantly lower MBL. Furthermore, PD and MBL were much lower around LMS neck implants than those around machined-neck or micro-threaded implants.
Collapse
Affiliation(s)
- Wayel Mohammed Huraib
- Department of Prosthodontics, Dentistry Program, Batterjee Medical College, Jeddah 21442, Saudi Arabia
| | - Fawaz Pullishery
- Division of Dental Public Health, Dentistry Program, Batterjee Medical College, Jeddah 21442, Saudi Arabia
| | | | | | - Haitham Binhuraib
- Consultant in Prosthodontics, North Jeddah Specialized Dental Center, King Abdullah Medical Complex, Jeddah, Saudi Arabia
| | - Mahmoud El Homossany
- Department of Removable Prosthodontics, Ain Shams University, Egypt and Batterjee Medical College, Jeddah 21442, Saudi Arabia
| | - Malak Saeed Bamigdad
- Department of Prosthodontics, Dentistry Program, Batterjee Medical College, Jeddah 21442, Saudi Arabia
| |
Collapse
|
2
|
Camps-Font O, Rubianes-Porta L, Valmaseda-Castellón E, Jung RE, Gay-Escoda C, Figueiredo R. Comparison of external, internal flat-to-flat, and conical implant abutment connections for implant-supported prostheses: A systematic review and network meta-analysis of randomized clinical trials. J Prosthet Dent 2023; 130:327-340. [PMID: 34776267 DOI: 10.1016/j.prosdent.2021.09.029] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 01/19/2023]
Abstract
STATEMENT OF PROBLEM The implant abutment connection interface has been considered one of the major factors affecting the outcome of implant therapy. However, drawbacks of traditional meta-analyses are the inability to compare more than 2 treatments at a time, which complicates the decision-making process for dental clinicians, and the lack of a network meta-analysis. PURPOSE The purpose of this network meta-analysis was to assess whether the implant abutment connection influences the outcome of implant-supported prostheses. MATERIAL AND METHODS An electronic search was undertaken to identify all randomized clinical trials comparing the effect of at least 2 different implant abutment connection designs published from 2009 up to May 2020. Outcome variables were implant survival rate, peri-implant marginal bone loss, and biologic and prosthetic complication rates at 12 months after prosthetic loading. Relevant information was extracted, and quality and risk of bias assessed. Pairwise meta-analyses and network meta-analyses based on a multivariate random-effects meta-regression were performed to assess the comparisons (α=.05 for all analyses). RESULTS For peri-implant marginal bone loss and prosthetic complications, conical interfaces were determined to be the most effective, with significant differences when compared with external hexagonal connections (P=.011 and P=.038, respectively). No significant differences were found among the implant abutment connections in terms of survival and biologic complications (P>.05 in all direct, indirect, and mixed comparisons). CONCLUSIONS After 1 year of loading, conical connections showed lower marginal bone loss and fewer prosthetic complications than external hexagonal connections. However, the implant abutment connection design had no influence on the implant survival and biologic complication rates.
Collapse
Affiliation(s)
- Octavi Camps-Font
- Associate Professor, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain.
| | - Laura Rubianes-Porta
- Graduate student, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Eduard Valmaseda-Castellón
- Professor, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Ronald E Jung
- Head of the Division of Implantology and Vice Chairman of the Center of Dental Medicine of the University of Zürich, Clinic for Fixed and Removable Prosthodontics and Dental Material Science, Zürich, Switzerland
| | - Cosme Gay-Escoda
- Chairman of Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Rui Figueiredo
- Professor, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| |
Collapse
|
3
|
Lee SJ, Alamri O, Cao H, Wang Y, Gallucci GO, Lee JD. Occlusion as a predisposing factor for peri-implant disease: A review article. Clin Implant Dent Relat Res 2023; 25:734-742. [PMID: 36373771 DOI: 10.1111/cid.13152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 10/23/2022] [Accepted: 10/25/2022] [Indexed: 08/04/2023]
Abstract
BACKGROUND The restoration of dental implants presents a unique challenge due to the intrinsic biomechanical differences between osseointegrated implants and natural teeth, and their subsequent responses to occlusal loading. However, controversy exists regarding the role that occlusion plays in the physiology of the peri-implant complex. PURPOSE To provide an overview of the scientific literature regarding occlusion as it relates to implant dentistry and peri-implant disease. MATERIALS AND METHODS This article presents a narrative review on occlusal loading and its potential effects on the peri-implant complex, as well as some generally accepted guidelines for occlusion in implant dentistry. RESULTS AND CONCLUSIONS Although there is strong evidence linking occlusal factors to mechanical complications of dental implants, the same cannot be said regarding biological complications. There is no clear scientific evidence on the relationship between occlusal overload and peri-implant disease. However, occlusal overload may be an accelerating factor for peri-implant disease in the presence of inflammation. As the biomechanical properties of dental implants differ from that of the natural dentition, modifications to classic concepts of occlusion may be necessary when dental implants are involved. Thus, clinical recommendations are proposed which function to minimize unfavorable occlusal forces on implant restorations and reduce the associated biological and mechanical complications.
Collapse
Affiliation(s)
- Sang J Lee
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Osamah Alamri
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Huilin Cao
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Yujun Wang
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - German O Gallucci
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Jason D Lee
- Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Tal H, Reiser V, Naishlos S, Avishai G, Kolerman R, Chaushu L. Screw-Type Collar vs. Non-Screw-Type Collar Implants—Comparison of Initial Stability, Soft Tissue Adaptation, and Early Marginal Bone Loss—A Preclinical Study in the Dog. BIOLOGY 2022; 11:biology11081213. [PMID: 36009840 PMCID: PMC9405267 DOI: 10.3390/biology11081213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 08/09/2022] [Accepted: 08/10/2022] [Indexed: 11/16/2022]
Abstract
Simple Summary Implant neck characteristics may affect initial implant stability, soft tissue healing, and early marginal bone loss (EMBL) at second-stage surgery. Screw-type rough-surface collar implants had statistically significant poorer soft tissue healing and increased marginal bone loss compared to non-screw type implants at the time of 2nd-stage surgery. The significance of the novel implant design results in preventing EMBL awaits further research. Abstract Background: Implant neck characteristics may affect initial implant stability, soft tissue healing, and early marginal bone loss (EMBL) at second-stage surgery. The null hypothesis was that, following two-stage implant insertion, rough surface, non-screw-type collar implants will present lower EMBL at 2nd-stage surgery than rough-surface, screw-type collar implants. Methods: The study comprised seven male beagle dogs (mean weight 10.57 ± 2.8 kg; range 9–17 kg). A novel implant design was developed, composed of 2 parts: an apical part resembling a regular threaded implant, and a coronal non-screw-type collar, 4.2 mm long, served as the study group, whereas standard threaded implants served as control. Twenty-eight implants were placed: two on each side of the mandible. All implants were sand-blasted/acid-etched and of similar dimensions. Each dog received four implants. To assess location (anterior vs. posterior) impact on the outcomes, implants were placed as follows: group I—posterior mandible right—non-screw-type collar implants; group II—anterior mandible right—similar non-screw-type collar implants. To assess the collar-design effect on the outcomes, implants were placed as follows—Group III—anterior mandible left—control group, screw-type collar implants; Group IV—study group, posterior mandible left—non-screw-type collar implants. The following parameters were measured and recorded: insertion torque, soft tissue healing, early implant failure, and EMBL at 2nd-stage surgery. Results: No statistically significant differences were noted between groups I and II regarding all outcome parameters. At the same time, although insertion torque (55 N/cm) and early implant failure (0) were similar between groups III and IV, group III presented significantly poorer soft tissue healing (1.43 vs. 0.14) and increased marginal bone loss (0.86 vs. 0 mm). Conclusions: When a two-stage implant protocol was used, rough-surface non-screw-type collar implants led to superior outcomes at 2nd-stage surgery. Implant location did not affect the results. The significance of this result in preventing EMBL awaits further research.
Collapse
Affiliation(s)
- Haim Tal
- Department of Periodontology and Oral Implantology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Vadim Reiser
- Department of Oral & Maxillofacial Surgery, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Department of Oral & Maxillofacial Surgery, Rabin Medical Center, Beilinson Campus, Petah Tikva 4941492, Israel
| | - Sarit Naishlos
- Department of Pedodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Gal Avishai
- Department of Oral & Maxillofacial Surgery, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Department of Oral & Maxillofacial Surgery, Rabin Medical Center, Beilinson Campus, Petah Tikva 4941492, Israel
| | - Roni Kolerman
- Department of Periodontology and Oral Implantology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Liat Chaushu
- Department of Periodontology and Oral Implantology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Correspondence: ; Tel.: +972-5082-1832
| |
Collapse
|
5
|
Chauhan P, Koul V, Bhatnagar N. Critical Role of Etching Parameters in the Evolution of Nano Micro SLA Surface on the Ti6Al4V Alloy Dental Implants. MATERIALS 2021; 14:ma14216344. [PMID: 34771869 PMCID: PMC8585160 DOI: 10.3390/ma14216344] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 10/05/2021] [Accepted: 10/09/2021] [Indexed: 01/12/2023]
Abstract
The surface of dental implants plays a vital role in early and more predictable osseointegration. SLA (sandblasted large grit and acid-etched) represents the most widely accepted, long-term clinically proven surface. Primarily, dental implants are manufactured by either commercially pure titanium (CP-Ti) or Ti6Al4V ELI alloy. The acid etch behavior of CP-Ti is well known and its effects on the surface microstructure and physicochemical properties have been studied by various researchers in the past. However, there is a lack of studies showing the effect of acid etching parameters on the Ti6Al4V alloy surface. The requirement of the narrow diameter implants necessitates implant manufacturing from alloys due to their high mechanical properties. Hence, it is necessary to have an insight on the behavior of acid etching of the alloy surface as it might be different due to changed compositions and microstructure, which can further influence the osseointegration process. The present research was carried out to study the effect of acid etching parameters on Ti6Al4V ELI alloy surface properties and the optimization of process parameters to produce micro- and nanotopography on the dental implant surface. This study shows that the Ti6Al4V ELI alloy depicts an entirely different surface topography compared to CP-Ti. Moreover, the surface topography of the Ti6Al4V ELI alloy was also different when etching was done at room temperature compared to high temperature, which in turn affected the behavior of the cell on these surfaces. Both microns and nano-level topography were achieved through the optimized parameters of acid etching on Ti6Al4V ELI alloy dental implant surface along with improved roughness, hydrophilicity, and enhanced cytocompatibility.
Collapse
Affiliation(s)
- Pankaj Chauhan
- Mechanical Engineering Department, Indian Institute of Technology, Delhi 110016, India;
- Centre for Biomedical Engineering, Indian Institute of Technology, Delhi 110016, India;
| | - Veena Koul
- Centre for Biomedical Engineering, Indian Institute of Technology, Delhi 110016, India;
| | - Naresh Bhatnagar
- Mechanical Engineering Department, Indian Institute of Technology, Delhi 110016, India;
- Correspondence:
| |
Collapse
|
6
|
Doornewaard R, Sakani S, Matthys C, Glibert M, Bronkhorst E, Vandeweghe S, Vervaeke S, De Bruyn H. Four-implant-supported overdenture treatment in the maxilla. Part I: A randomized controlled split mouth trial assessing the effect of microthreads and abutment connection type on 4 years peri-implant health. Clin Implant Dent Relat Res 2021; 23:671-679. [PMID: 34378860 DOI: 10.1111/cid.13037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 06/18/2021] [Accepted: 07/19/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND According to literature, peri-implant bone loss is minimized on implants with microthreaded neck design and internal type of abutment connection. However, most clinical studies may be biased due to confounding factors. PURPOSE This nonblinded RCT assessed the effect of implant neck (microthreaded vs non-microthreaded) as well as the type of abutment connection (internal conical vs external flat-to-flat) on peri-implant bone stability and peri-implant health after at least 36 months. MATERIALS AND METHODS Twenty-five patients were treated with a maxillary implant-supported bar-retained overdenture on four different implant types: internal connection with microthreads (I-MT), internal connection without microthreads (I-NMT), external connection with microthreads (E-MT), and external connection without microthreads (E-NMT). To control confounding factors, all other design features were similar. A linear mixed-model analysis or mixed-model logistic regression analysis was used to determine the effect of implant type on bone level, probing pocket depth, bleeding on probing, and plaque. RESULTS Four out of 98 implants (4.1%) placed in 25 patients failed during provisionalization and were replaced. Mean overall bone loss after 6 months was 0.39 mm (SD 0.62, range 0.00-3.48) with limited additional bone loss of 0.04 mm (SD 0.54, range -1.80-1.63) after at least 3 years. Microthreads or connection type had no effect on the bone level, probing pocket depth, bleeding on probing, nor plaque. CONCLUSIONS With 96% of implant survival, the maxillary overdenture supported with a bar on four implants yield a predictable outcome and the implant-abutment connection type (internal vs external) and implant neck design (microthreaded vs non-microthreaded) have no influence on peri-implant bone remodeling after initial bone remodeling nor up to 4 years of function. Peri-implant bone levels are within international success standards and peri-implant health is indicative of absence of peri-implantitis.
Collapse
Affiliation(s)
- Ron Doornewaard
- Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium.,Department of Dentistry, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Samir Sakani
- Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium
| | - Carine Matthys
- Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium
| | - Maarten Glibert
- Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium
| | - Ewald Bronkhorst
- Department of Dentistry, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Stefan Vandeweghe
- Department of Reconstructive Dentistry, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium
| | - Stijn Vervaeke
- Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium
| | - Hugo De Bruyn
- Department of Periodontology & Oral Implantology, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium.,Department of Dentistry, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| |
Collapse
|
7
|
Sicilia A, Gallego L, Sicilia P, Mallo C, Cuesta S, Sanz M. Crestal bone loss associated with different implant surfaces in the posterior mandible in patients with a history of periodontitis. A retrospective study. Clin Oral Implants Res 2021; 32:88-99. [PMID: 33210774 DOI: 10.1111/clr.13682] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 08/26/2020] [Accepted: 10/25/2020] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To retrospectively assess the interproximal bone loss (CBL) in external hexagon implants (EHI), with different surface micro-topography, placed in the posterior mandible in patients with a history of periodontitis undergoing supportive periodontal care. MATERIAL AND METHODS 268 consecutive patients received 755 EHI implants in the mandibular molar region between 2007 and 2015 with the following surface characteristics: 72 turned, 145 hybrids (double acid-etched/turned), and 538 anodized. CBL was yearly evaluated by analysing calibrated digital periapical radiographs, with a follow-up of 1-6 years. Data on implant survival were also calculated. RESULTS At 6 years (53 patients), the mean CBL was 1.34/1.42 mm at patient/implant level, respectively (range: 0-5.2 mm). Significantly higher CBL was detected in anodized implants than in turned and hybrid implants (1.92/1.46/1.02 mm) (p < .01). The maximum CBL values were found in 2 anodized implants at 4 years (6.3 and 8.1 mm). CBL ≥2 mm was detected in 18% of implants at 3 years and 35% at 6 (p < 2.2 × 10-16 ), this prevalence being 2.6 times higher in the anodized than in the hybrid and turned group (40%/15.6%, p < .0094). At 6 years, 25 anodized implants presented CBL ≥3 mm (18%). 6 anodized implants (5 patients) were removed between 4 and 5 years. CONCLUSION A significant higher CBL was observed in anodized, compared to hybrid and turned implants, when placed in the mandibular molar region of periodontal patients, with a follow-up of 1 to 6 years.
Collapse
Affiliation(s)
- Alberto Sicilia
- Section of Periodontology, Faculty of Health Sciences, University Clinic of Odontology, University of Oviedo, Oviedo, Spain
| | - Luis Gallego
- Section of Periodontology, Faculty of Health Sciences, University Clinic of Odontology, University of Oviedo, Oviedo, Spain
| | - Pelayo Sicilia
- Section of Periodontology, Faculty of Health Sciences, University Clinic of Odontology, University of Oviedo, Oviedo, Spain
| | - Carmen Mallo
- Section of Periodontology, Faculty of Health Sciences, University Clinic of Odontology, University of Oviedo, Oviedo, Spain
| | - Susana Cuesta
- Section of Periodontology, Faculty of Health Sciences, University Clinic of Odontology, University of Oviedo, Oviedo, Spain
| | - Mariano Sanz
- Faculty of Odontology, ETEP Research Group, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
8
|
Jin ZH, Peng MD, Li Q. The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis. J Dent Sci 2020; 15:466-471. [PMID: 33505618 PMCID: PMC7816038 DOI: 10.1016/j.jds.2019.12.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 12/02/2019] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND/PURPOSE Significant research has proposed that the implant with microthread in the neck can significantly reduce marginal bone loss, but whether it is consistent in the condition of marginal bone loss is still unknown. The objective of this study is to investigate the effect of microthread on stress distribution in peri-implant bone with different bone level using finite element analysis. MATERIALS AND METHODS A series of computational models of mandible segments with different bone resorption and implant models with or without microthread in the neck was installed by computer-aided design software. The simulated occlusal force of 150N was applied buccolingually on the top center point of implant. The FEA was performed, and the von Mises stress, principal stress and shear stress in peri-implant bone were recorded and analyzed. RESULTS In all models, the T-neck group exhibits higher von Mises stress and principal stress, as well as lower shear stress than S-neck group. Three types of stresses increase with the depth of bone resorption developed, but the differences of shear stress between two groups of implants were gradually decreased. CONCLUSION The micro-thread design in implant neck can reduce marginal bone loss by decreasing shear stress in peri-implant bone, but this effect is gradually weakened with the decline of the marginal bone level.
Collapse
Affiliation(s)
- Zhi-Heng Jin
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST), Key Laboratory of Oral Biomedicine Ministry of Education, School and Hospital of Stomatology, Wuhan, China
- Dept. of Prosthodontics, Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Meng-Dong Peng
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST), Key Laboratory of Oral Biomedicine Ministry of Education, School and Hospital of Stomatology, Wuhan, China
- Dept. of Prosthodontics, Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Qing Li
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST), Key Laboratory of Oral Biomedicine Ministry of Education, School and Hospital of Stomatology, Wuhan, China
- Dept. of Prosthodontics, Hospital of Stomatology, Wuhan University, Wuhan, China
| |
Collapse
|
9
|
Taheri M, Akbari S, Shamshiri AR, Shayesteh YS. Marginal bone loss around bone-level and tissue-level implants: A systematic review and meta-analysis. Ann Anat 2020; 231:151525. [PMID: 32380195 DOI: 10.1016/j.aanat.2020.151525] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 03/19/2020] [Accepted: 04/07/2020] [Indexed: 12/15/2022]
Abstract
PURPOSE To review the scientific evidence regarding the marginal bone loss around the tissue-level and bone-level implants. METHODS MEDLINE-PubMed and EMBASE databases were searched for the relevant English articles (up to February 2019) assessing the marginal bone loss (MBL) as the primary outcome. To be selected, studies were supposed to directly mention "tissue-level" and "bone-level" implants or implants with and without a smooth neck. Relevant data were extracted and meta-analysis was performed to evaluate the effect of implant neck design. RESULTS A total of 19 studies (10 clinical, and 9 RCT studies) were included for qualitative analysis. There was a vast heterogeneity between studies in terms of implant designs and study protocol. Out of 19 articles included, 11 studies reached to a statistically significant difference in MBL between the groups; however, the differences were not found to be clinically relevant. Bone-level implants with platform-switched abutments in most of the cases showed better marginal bone stability compared to tissue-level implants or bone-level implants with matching abutments. Seven RCTs with 12 months follow-up data were selected for meta-analysis (I2=93%; heterogeneous), and the results showed less MBL around bone-level implants compared to tissue-level group (WMD=-0.21mm; 95% CI -0.42, 0.00; P=0.06). CONCLUSION The available data regarding comparison of MBL around bone-level and tissue-level implants are heterogeneous. Bone-level implants with platform switching may better preserve crestal bone.
Collapse
Affiliation(s)
- Mina Taheri
- Department of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| | - Solmaz Akbari
- Department of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| | - Ahmad Reza Shamshiri
- Research Center for Caries Prevention, Dentistry Research Institute, Department of Community Oral Health, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| | | |
Collapse
|
10
|
Chiapasco M, Tommasato G, Palombo D, Del Fabbro M. A retrospective 10‐year mean follow‐up of implants placed in ridges grafted using autogenous mandibular blocks covered with bovine bone mineral and collagen membrane. Clin Oral Implants Res 2020; 31:328-340. [DOI: 10.1111/clr.13571] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 11/26/2019] [Accepted: 12/22/2019] [Indexed: 11/30/2022]
Affiliation(s)
- Matteo Chiapasco
- Unit of Oral Surgery Department of Biomedical, Surgical, and Dental Sciences St. Paolo and St. Carlo Hospitals, Dental Clinic, University of Milan Milan Italy
| | - Grazia Tommasato
- Unit of Oral Surgery Department of Biomedical, Surgical, and Dental Sciences St. Paolo and St. Carlo Hospitals, Dental Clinic, University of Milan Milan Italy
| | - David Palombo
- Unit of Oral Surgery Department of Biomedical, Surgical, and Dental Sciences St. Paolo and St. Carlo Hospitals, Dental Clinic, University of Milan Milan Italy
| | - Massimo Del Fabbro
- IRCCS Orthopedic Institute Galeazzi, Dental Clinic Milan Italy
- Department of Biomedical, Surgical, and Dental Sciences Dental Clinic IRCCS Istituto Ortopedico Galeazzi University of Milan Milan Italy
| |
Collapse
|
11
|
Delgado-Ruiz RA, Calvo-Guirado JL, Romanos GE. Effects of occlusal forces on the peri-implant-bone interface stability. Periodontol 2000 2019; 81:179-193. [PMID: 31407438 DOI: 10.1111/prd.12291] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The occlusal forces and their influence on the initiation of peri-implant bone loss or their relationship with peri-implantitis have created discussion during the past 30 years given the discrepancies observed in clinical, animal, and finite element analysis studies. Beyond these contradictions, in the case of an osseointegrated implant, the occlusal forces can influence the implant-bone interface and the cells responsible for the bone remodeling in different ways that may result in the maintenance or loss of the osseointegration. This comprehensive review focuses on the information available about the forces transmitted through the implant-crown system to the implant-bone interface and the mechano-transduction phenomena responsible for the bone cells' behavior and their interactions. Knowledge of the basic molecular biology of the peri-implant bone would help clinicians to understand the complex phenomenon of occlusal forces and their effects on the implant-bone interface, and would allow better control of the negative effects of mechanical stresses, leading to therapy with fewer risks and complications.
Collapse
Affiliation(s)
- Rafael Arcesio Delgado-Ruiz
- Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Jose Luis Calvo-Guirado
- International Dentistry Research Cathedra, Faculty of Medicine and Dentistry, Universidad Catolica San Antonio De Murcia (UCAM), Murcia, Spain
| | - Georgios E Romanos
- Department of Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA.,Department of Oral Surgery and Implant Dentistry, Johann Wolfgang Goethe University, Frankfurt, Germany
| |
Collapse
|
12
|
Díaz-Sánchez RM, Delgado-Muñoz JM, Serrera-Figallo MA, González-Martín MI, Torres-Lagares D, Gutiérrez-Pérez JL. Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomized prospective clinical trial. Med Oral Patol Oral Cir Bucal 2019; 24:e260-e264. [PMID: 30818320 PMCID: PMC6441592 DOI: 10.4317/medoral.22742] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 01/31/2019] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. MATERIAL AND METHODS Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for crestal bone analysis and an Implant stability quotient by resonance frequency analysis (ISQ) analysis were taken at baseline and the reviews. RESULTS No statistically significant differences were found in the Implant stability quotient by resonance frequency analysis and Marginal Bone Loss in the four types of implants. The ISQ increased from the moment of insertion of the implant until the revision to the year, showing an increase of the stability implant, being this increasing less between the 6 months and the year. CONCLUSIONS Differences in the design of the four implants tested in this study did not show statistically significant differences in any of the variables studied, so the implant design does not influence implant stability and marginal bone loss in the first year after placement.
Collapse
Affiliation(s)
- R-M Díaz-Sánchez
- Dental School, University of Seville, C) Avicena s/n, 41009 Sevilla, Spain,
| | | | | | | | | | | |
Collapse
|
13
|
Lemos CAA, Verri FR, Gomes JMDL, de Souza Batista VE, Cruz RS, Oliveira HFFE, Pellizzer EP. Ceramic versus metal-ceramic implant-supported prostheses: A systematic review and meta-analysis. J Prosthet Dent 2019; 121:879-886.e4. [PMID: 30661882 DOI: 10.1016/j.prosdent.2018.09.016] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 09/18/2018] [Accepted: 09/19/2018] [Indexed: 11/16/2022]
Abstract
STATEMENT OF PROBLEM There is insufficient evidence to recommend the restorative material for implant-supported prostheses. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate studies that compared ceramic and metal-ceramic restorations for implant-supported prostheses (within the same study to avoid indirect comparison) in terms of the mechanical and biological complication rates, prosthesis survival rate, and marginal bone loss. MATERIAL AND METHODS Two independent reviewers performed a comprehensive search in databases (PubMed/MEDLINE, Web of Science, and Cochrane Library) for articles indexed until March 31, 2018. The search was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and methods were registered in the International Prospective Register of Systematic Reviews (PROSPERO). The focused question was "Do ceramic restorations have mechanical/biological complication rates, prosthesis survival rates, and marginal bone loss similar to those of metal-ceramic restorations?" RESULTS The search identified 949 references. The interinvestigator agreement using kappa values was 0.87 for PubMed/MEDLINE, 0.93 for Scopus, and 1.0 for the Cochrane Library. After analysis, 12 studies were selected for qualitative and quantitative analysis. The mechanical complication rate did not differ between ceramic and metal-ceramic restorations (P=.89), independent of the type of prostheses (single crown: P=.63; fixed partial denture: P=.65). The biological complication rate was also not significantly different between ceramic and metal-ceramic restorations (P=.21). The prosthesis survival rate showed no significant differences between the 2 types of restorations (P=.56). Marginal bone loss was also similar for both types of restorations (P=.12). CONCLUSIONS This systematic review indicated that ceramic and metal-ceramic implant-supported prostheses have similar mechanical and biological complication rates, prosthesis survival rates, and marginal bone loss. Thus, both treatments are appropriate options for long-term rehabilitation treatment.
Collapse
Affiliation(s)
- Cleidiel Aparecido Araújo Lemos
- Postgraduate student, Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil.
| | - Fellippo Ramos Verri
- Adjunct Professor, Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil
| | - Jéssica Marcela de Luna Gomes
- Postgraduate student, Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil
| | - Victor Eduardo de Souza Batista
- Associate Professor, Department of Prosthodontics, Presidente Prudente Dental School, University of Western São Paulo (UNOESTE), Presidente Prudente, Brazil
| | - Ronaldo Silva Cruz
- Postgraduate student, Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil
| | | | - Eduardo Piza Pellizzer
- Professor, Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil
| |
Collapse
|
14
|
Donovan TE, Marzola R, Murphy KR, Cagna DR, Eichmiller F, McKee JR, Metz JE, Albouy JP, Troeltzsch M. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2018; 120:816-878. [DOI: 10.1016/j.prosdent.2018.09.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 09/24/2018] [Indexed: 02/08/2023]
|
15
|
Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial. BIOMED RESEARCH INTERNATIONAL 2018; 2018:6817154. [PMID: 30186865 PMCID: PMC6112219 DOI: 10.1155/2018/6817154] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 08/05/2018] [Indexed: 12/30/2022]
Abstract
Aim To compare implant survival rate and marginal bone loss (MBL) of immediately loaded single implants inserted by using ultrasonic implant site preparation (UISP) (test) and conventional rotary instrumentation (control). Methods Two single implants were inserted for each patient: after randomization, test site was prepared by using an ultrasonic device (Piezosurgery Touch, Mectron, Italy) and control site was prepared by using the drills of the selected implant system (Premium AZT, Sweden & Martina, Italy), until reaching a final diameter of 3 mm in both groups. Identical implants (3.8x11.5 mm) were inserted in all sites at crestal level. Impressions were taken and screwed resin single crowns with platform-switched provisional abutments were delivered with 48 hours. Periapical radiographs were taken at provisional crown insertion (T0), 6 months (T1) and one year (T2) after prosthetic loading to measure MBL. All data were tested for normality and subsequently analyzed by paired samples t-test and forward multiple linear regression. Results Forty-eight patients were treated in six centers with the insertion of ninety-six implants (48 test; 48 control). Four implants in four patients failed within the first six months of healing (two in test group; two in control group; no difference between groups). Forty patients (age 60.1±10.7 years; 22 female, 18 male) were included in the final analysis. Mean MBL after six months of loading was 1.39±1.03 mm in the test group and 1.42±1.16 mm in the control group (p>0.05) and after one year was 1.92±1.14 mm and 2.14±1.55 mm in test and control, respectively (p>0.05). Conclusions No differences in survival rate and MBL were demonstrated between UISP and conventional site preparation with rotary instruments in immediately loaded dental implants: UISP, with its characteristics of enhanced surgical control and safety in proximity of delicate structures, may be used as a reliable alternative to the traditional drilling systems.
Collapse
|
16
|
Abstract
Systematic reviews of literature over the period between 2008 and 2017 are discussed regarding clinical evidence for the factors affecting survival and failure of dental implants. The factors addressed include publication bias, tooth location, insertion torque, collar design, implant-abutment connection design, implant length, implant width, bone augmentation, platform switching, surface roughness, implant coatings, and the use of ceramic materials in the implant body and abutment.
Collapse
Affiliation(s)
- Jason A Griggs
- Biomedical Materials Science, The University of Mississippi Medical Center School of Dentistry, 2500 North State Street, Room D528, Jackson, MS 39216-4505, USA.
| |
Collapse
|
17
|
Chiapasco M, Tommasato G, Palombo D, Scarnò D, Zaniboni M, Del Fabbro M. Dental implants placed in severely atrophic jaws reconstructed with autogenous calvarium, bovine bone mineral, and collagen membranes: A 3- to 19-year retrospective follow-up study. Clin Oral Implants Res 2018; 29:725-740. [PMID: 29876968 DOI: 10.1111/clr.13281] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Accepted: 04/23/2018] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To present the clinical, radiographic, and patient-related outcomes of patients presenting with severely resorbed ridges reconstructed with autogenous calvarial bone blocks and rehabilitated with implant-supported prostheses. MATERIAL AND METHODS From 1998 to 2014, 72 patients presenting with severe bone defects were reconstructed with autogenous calvarial bone blocks covered with bovine bone mineral granules and collagen membranes. Four to 9 months later, 330 implants were placed and loaded 3-9 months later. The follow-up ranged from 3 to 19 years (mean: 8.1 years). The following parameters were recorded: (a) complication rate of the reconstructive procedure; (b) bone resorption before implant placement; (c) implant survival rate and implant-related complications; (d) peri-implant bone resorption; and (e) patient's satisfaction inquired with a dedicated questionnaire. RESULTS No patients developed severe complications, such as complete loss or resorption of the grafts. A dehiscence occurred in six patients, which developed a mild graft resorption. The mean peri-implant bone resorption before implant placement was 0.13 mm (SD ± 0.71). All patients received the planned number of implants. Three patients were lost during the follow-up. The survival rate of implants at the end of the observation period was 98.5%. The mean peri-implant bone resorption ranged from 0.00 to 4.87 mm (mean: 1.11 mm). At last, 90% of the patients were very satisfied as regards the treatment received. CONCLUSIONS Results from this study suggested that: (a) bone volume in the areas reconstructed with calvarial grafts was stable over time; (b) survival rates of implants were consistent with those reported for implants placed in native bone; (c) patient's satisfaction was high.
Collapse
Affiliation(s)
- Matteo Chiapasco
- Unit of Oral Surgery, Department of Biomedical, Surgical, and Dental Sciences, St. Paolo and St. Carlo Hospital, Dental Clinic, University of Milan, Milan, Italy
| | - Grazia Tommasato
- Unit of Oral Surgery, Department of Biomedical, Surgical, and Dental Sciences, St. Paolo and St. Carlo Hospital, Dental Clinic, University of Milan, Milan, Italy
| | - David Palombo
- Unit of Oral Surgery, Department of Biomedical, Surgical, and Dental Sciences, St. Paolo and St. Carlo Hospital, Dental Clinic, University of Milan, Milan, Italy
| | - Dario Scarnò
- Unit of Oral Surgery, Department of Biomedical, Surgical, and Dental Sciences, St. Paolo and St. Carlo Hospital, Dental Clinic, University of Milan, Milan, Italy
| | - Marco Zaniboni
- Private Practice in Milan and Bassano del Grappa (VI), Milan, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical, and Dental Sciences, Dental Clinic, IRCCS Istituto Ortopedico Galeazzi, University of Milan, Milan, Italy
| |
Collapse
|
18
|
Gallego L, Sicilia A, Sicilia P, Mallo C, Cuesta S, Sanz M. A retrospective study on the crestal bone loss associated with different implant surfaces in chronic periodontitis patients under maintenance. Clin Oral Implants Res 2018; 29:557-567. [DOI: 10.1111/clr.13153] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/16/2018] [Indexed: 01/21/2023]
Affiliation(s)
- Luis Gallego
- Section of Periodontology; Faculty of Medicine and Health Sciences; University Clinic of Odontology; University of Oviedo; Oviedo Spain
| | - Alberto Sicilia
- Section of Periodontology; Faculty of Medicine and Health Sciences; University Clinic of Odontology; University of Oviedo; Oviedo Spain
| | - Pelayo Sicilia
- International University of Cataluña (UIC); Barcelona Spain
| | - Carmen Mallo
- Section of Periodontology; Faculty of Medicine and Health Sciences; University Clinic of Odontology; University of Oviedo; Oviedo Spain
| | - Susana Cuesta
- Section of Periodontology; Faculty of Medicine and Health Sciences; University Clinic of Odontology; University of Oviedo; Oviedo Spain
| | - Mariano Sanz
- Periodontology; Faculty of Odontology; University Complutense of Madrid; Madrid Spain
| |
Collapse
|
19
|
Does Oral Implant Design Affect Marginal Bone Loss? Results of a Parallel-Group Randomized Controlled Equivalence Trial. BIOMED RESEARCH INTERNATIONAL 2018; 2018:8436437. [PMID: 29610765 PMCID: PMC5831983 DOI: 10.1155/2018/8436437] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 01/01/2018] [Indexed: 11/17/2022]
Abstract
Objective To test whether or not the modified design of the test implant (intended to increase primary stability) has an equivalent effect on MBL compared to the control. Methods Forty patients were randomly assigned to receive test or control implants to be installed in identically dimensioned bony beds. Implants were radiographically monitored at installation, at prosthetic delivery, and after one year. Treatments were considered equivalent if the 90% confidence interval (CI) for the mean difference (MD) in MBL was in between −0.25 and 0.25 mm. Additionally, several soft tissue parameters and patient-reported outcome measures (PROMs) were evaluated. Linear mixed models were fitted for each patient to assess time effects on response variables. Results Thirty-three patients (21 males, 12 females; 58.2 ± 15.2 years old) with 81 implants (47 test, 34 control) were available for analysis after a mean observation period of 13.9 ± 4.5 months (3 dropouts, 3 missed appointments, and 1 missing file). The adjusted MD in MBL after one year was −0.13 mm (90% CI: −0.46–0.19; test group: −0.49; control group: −0.36; p = 0.507). Conclusion Both implant systems can be considered successful after one year of observation. Concerning MBL in the presented setup, equivalence of the treatments cannot be concluded. Registration This trial is registered with the German Clinical Trials Register (ID: DRKS00007877).
Collapse
|
20
|
Starch-Jensen T, Christensen AE, Lorenzen H. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis. EJOURNAL OF ORAL MAXILLOFACIAL RESEARCH 2017; 8:e2. [PMID: 28496962 PMCID: PMC5423307 DOI: 10.5037/jomr.2017.8102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2017] [Accepted: 03/28/2017] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. RESULTS The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. CONCLUSIONS A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level.
Collapse
Affiliation(s)
- Thomas Starch-Jensen
- Department of Oral and Maxillofacial Surgery, Aalborg University Hospital, AalborgDenmark
| | - Ann-Eva Christensen
- Unit of Epidemiology and Biostatistics, Aalborg University Hospital, AalborgDenmark
| | - Henning Lorenzen
- Department of Oral and Maxillofacial Surgery, Aalborg University Hospital, AalborgDenmark
| |
Collapse
|