1
|
Fernandes V, Fidalgo-Pereira R, Edwards J, Silva F, Özcan M, Carvalho Ó, Souza JCM. Fitting of Different Intraradicular Composite Posts to Oval Tooth Root Canals: A Preliminary Assessment. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2520. [PMID: 38893784 PMCID: PMC11174052 DOI: 10.3390/ma17112520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 04/30/2024] [Accepted: 05/15/2024] [Indexed: 06/21/2024]
Abstract
The purpose of the present study was to perform a preliminary analysis of the fitting of different fiber-reinforced composite (GFRC) posts to tooth root canals and determine the resin cement layer thickness. The following GFRC posts were assessed: bundle posts (Rebilda GTTM, VOCO, Germany), sleeve system (SAPTM, Angelus Ind, Brazil), and accessory posts (ReforpinTM, Angelus, Brazil). Twenty-four freshly extracted mandibular single-rooted pre-molars were endodontically treated and divided into six groups, according to the type of GFRC post and resin cement (self-adhesive or conventional dual-cured). Then, specimens were cross-sectioned and inspected by optical microscopy regarding the cement layer thickness and presence of defects such as pores, voids, or fissures were assessed. Bundle and accessory posts revealed a regular distribution of resin cement with a lower number of voids than found with sleeve systems. The sleeve system posts showed poor fitting at the apical portion of the root canals. The type of resin cement did not affect the thickness of the interface, although both bundle and accessory posts allow a better distribution of resin cement and fibers. The present preliminary study reveals interesting insights on the fitting of bundle and accessory posts to root dentin and resin cement layer thickness in oval-shape root canals. The sleeve system posts showed adequate fitting only at the coronal portion of the canals.
Collapse
Affiliation(s)
- Valter Fernandes
- University Institute of Health Sciences (IUCS), Cooperativa Ensino Superior Universitário (CESPU), 4585-116 Gandra, Portugal
| | - Rita Fidalgo-Pereira
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505 Viseu, Portugal
| | - Jane Edwards
- University Institute of Health Sciences (IUCS), Cooperativa Ensino Superior Universitário (CESPU), 4585-116 Gandra, Portugal
| | - Filipe Silva
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal; (F.S.); (Ó.C.)
- LABBELS—Associate Laboratory, University of Minho, 4710-057 Braga, Portugal
| | - Mutlu Özcan
- Clinic for Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland;
| | - Óscar Carvalho
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal; (F.S.); (Ó.C.)
- LABBELS—Associate Laboratory, University of Minho, 4710-057 Braga, Portugal
| | - Júlio C. M. Souza
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505 Viseu, Portugal
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal; (F.S.); (Ó.C.)
- LABBELS—Associate Laboratory, University of Minho, 4710-057 Braga, Portugal
| |
Collapse
|
2
|
Barros APO, Costa JLDSG, de Melo AC, Galvani LD, Dantas AAR, Kuga MC. Evaluation of bond strength in customizing fiber post using translucent resins photoactivated by different light-emitting diodes. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:408-413. [PMID: 38779204 PMCID: PMC11108413 DOI: 10.4103/jcde.jcde_14_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/15/2024] [Accepted: 02/26/2024] [Indexed: 05/25/2024]
Abstract
Aims The objective of the study was to evaluate two translucent resin composite systems for customizing light-polymerized fiber posts with light-emitting diode (LED) curing units regarding adhesion using conventional cement at 24 h and 6 months. Settings and Design This was an experimental in vitro study. Methods Forty roots were prepared and divided into four groups (n = 10): ZV-Z350 resin and LED Valo; ZR-Z350 resin and LED Radii-Cal; OV-Opallis resin and LED Valo; and OR-Opallis resin and LED Radii-Cal. The fiber post was customized and cemented with conventional resin cement and was photoactivated by two different sources. Statistical Analysis Used The data were subjected to two-way ANOVA and Tukey's post hoc tests (P = 0.05). The data regarding the pattern of adhesive failures were described in terms of the frequency of occurrence in each third of the postspace. Results Both at 24 h and 6 months, bond strength among groups was similar, regardless of the analyzed postspace 3rd (P > 0.05). Adhesive failure Type 4 was the most frequent in all thirds. Conclusions Customizing the fiber post with Z350 and Opallis has the same effect on bond strength and adhesive failure pattern, regardless of the LED curing units used for photopolymerization.
Collapse
Affiliation(s)
- Antonia Patricia O. Barros
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University – UNESP, Araraquara, SP, Brazil
| | - Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University – UNESP, Araraquara, SP, Brazil
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais – UFMG, Belo Horizonte, MG, Brazil
| | | | - Lucas David Galvani
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University – UNESP, Araraquara, SP, Brazil
| | - Andrea Abi Rached Dantas
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University – UNESP, Araraquara, SP, Brazil
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University – UNESP, Araraquara, SP, Brazil
| |
Collapse
|
3
|
Alkhalidi EF, Ahmad ZA. Bond Strength of New Fiber Post-system (Rebilda GT). Open Access Maced J Med Sci 2022. [DOI: 10.3889/oamjms.2022.10174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIM: The aim of this in vitro study is to determine the push-out bond strength of bundle glass fiber post (Rebilda GT) and tapered glass fiber post (Rebilda fiber post).
MATERIALS AND METHODS: Twenty freshly extracted human single rooted premolar teeth were used, all teeth were endodontically treated, after 24 h from obturation the gutta-percha removed leaving 5 mm apically to ensure clinically acceptable apical seal. Finally, all canals were flushed with 2 ml NaOcl 5.25% and 2 ml distilled water, respectively, then the canals were dried using paper points. The roots were divided randomly into two sets with ten roots for each group according to post-type. Group A: Rebilda fiber posts were used. Group B: Rebilda GT bundle fiber posts were used. The posts were inserted into the canals according to the manufacturer instructions. All specimens were stored for 72 h in an incubator. Slices of 2 mm thickness were cut from the roots at different levels (cervical, middle, and apical thirds), bond strength was determined using universal testing machine at a speed of 0.5 mm/min.
RESULTS: One-way analysis of variance and Tukey HSD tests showed that the (bundle fiber) Rebilda GT fiber post had bond strength higher than that of the Rebilda fiber post in all regions. (p < 0.05), also the cervical area showed higher bond strength in both groups than the middle and the apical areas, respectively.
CONCLUSIONS: The bundle glass fiber post (Rebilda GT) showed bond strength higher than the taper glass fiber (Rebilda fiber) post in all regions (apical, middle, and cervical). The cervical region showed higher bond strength than the middle and the apical thirds.
Collapse
|
4
|
Lins RBE, Cordeiro JM, Rangel CP, Antunes TBM, Martins LRM. The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study. Restor Dent Endod 2019; 44:e37. [PMID: 31799165 PMCID: PMC6875538 DOI: 10.5395/rde.2019.44.e37] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 09/15/2019] [Accepted: 09/15/2019] [Indexed: 11/29/2022] Open
Abstract
Objectives This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.
Collapse
Affiliation(s)
- Rodrigo Barros Esteves Lins
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| | - Jairo Matozinho Cordeiro
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Carolina Perez Rangel
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
| | | | | |
Collapse
|
5
|
Pang NS, Jung BY, Roh BD, Shin Y. Comparison of Self-Etching Ceramic Primer and Conventional Silanization to Bond Strength in Cementation of Fiber Reinforced Composite Post. MATERIALS 2019; 12:ma12101585. [PMID: 31096562 PMCID: PMC6567077 DOI: 10.3390/ma12101585] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 05/14/2019] [Accepted: 05/14/2019] [Indexed: 11/23/2022]
Abstract
Various mechanical and chemical surface treatments have been proposed to improve the retention of fiber-reinforced composite post (FRCP), but the results are still controversial. The bond strength and durability of a self-etching ceramic primer, which was recently released as an alternative to etching and silane, are not yet known. This study aimed to compare and evaluate the push-out bond strength of different surface treatments of FRCPs after an artificial aging procedure. Four groups (n = 10) were established to evaluated FRCP surface treatments (dentin adhesive bonding; silane and adhesive bonding; hydrofluoric acid, silane and adhesive bonding; and a self-etching ceramic primer). They were bonded with dual-curing rein cement (Multilink N) and stored in distilled water at 37 °C for 30 days, then thermal cycled for 7500 cycles. After being sectioned into 1 mm thickness, each coronal and apical part was evaluated for its the push-out bond strength by a universal testing machine. Each debonded specimen was observed by an optical microscope and divided according to the failure modes. The results showed that silane treatment significantly improved push-out bond strength, but the self-etching ceramic primer did not do so. Additional hydrofluoric acid treatment or the adhesive bonding agent alone did not significantly improve the retention of FRCPs. Cohesive failure of the luting material was found most frequently in all groups.
Collapse
Affiliation(s)
- Nan-Sim Pang
- Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| | - Bock-Young Jung
- Department of Advanced General Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| | - Byoung-Duck Roh
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| | - Yooseok Shin
- Department of Conservative Dentistry, Oral Science Research Center and Microscope center, College of Dentistry, Yonsei University, Seoul 03722, Korea.
| |
Collapse
|
6
|
Farid F, Rostami K, Habibzadeh S, Kharazifard M. Effect of cement type and thickness on push-out bond strength of fiber posts. J Dent Res Dent Clin Dent Prospects 2019; 12:277-282. [PMID: 30774794 PMCID: PMC6368945 DOI: 10.15171/joddd.2018.043] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Accepted: 11/10/2018] [Indexed: 11/09/2022] Open
Abstract
Background. This study investigated the effect of the thickness of two resin cements on push-out bond strength of fiber posts to root dentin.
Methods. Sixty decoronated single-rooted teeth were endodontically treated. The specimens were then randomly allocated to two groups (n=30); group 1: drill size 90 w, matching the size of fiber posts used; group 2: drill size 110, larger than the posts. The specimens in each group were divided into 2 subgroups (n=15); subgroup SE, in which the posts were cemented with self-etch Panavia F2.0 and subgroup SA, in which self-adhesive Panavia cement was used. After 72 hours, 2 slices with 1 mm of thickness were prepared from the mid-root of each specimen. Push-out bond strength test was performed in a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with two-way ANOVA and t-test.
Results. The mean bond strengths of the posts cemented in matched-size spaces for SE and SA groups were 4.02±1.6 and 4.12±2.3 MPa, respectively. For posts cemented in oversized spaces, the values were 4.9±2.3 and 2.8±1.3 MPa, respectively. In matched-size spaces, there was no significant difference between the two groups.
Conclusion. The results of this study suggested that increasing the cement thickness would reduce the bond strength of fiber posts to root dentin when self-adhesive cements are used; however, self-etch adhesives were not affected.
Collapse
Affiliation(s)
- Farzaneh Farid
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Khadijeh Rostami
- DDS, School of Dentistry, International Branch, Tehran University of Medical Sciences, Tehran, Iran
| | - Sareh Habibzadeh
- Department of Prosthodontics, School of Dentistry, International Branch, Tehran University of Medical Sciences, Tehran, Iran
| | | |
Collapse
|
7
|
CONTE T, ANDRADE GSD, GADONSKI AP, SANTIN DC, NAUFEL FS. Evaluation of the effect of chlorhexidine and sodium hypochlorite in adhesive cementation of fiber posts - in vitro study. REVISTA DE ODONTOLOGIA DA UNESP 2019. [DOI: 10.1590/1807-2577.02019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Abstract Introduction The attachment of fiberglass posts is achieved through an adhesive process. Failures in adhesion may occur due to the hydrolytic degradation of the adhesives, or to the degradation of the collagen fibres of the hybrid layer by intrinsic enzymes. Objective To evaluate the effect of chlorhexidine and sodium hypochlorite treatment on bond strength to dentin. Material and method Thirty bovine roots were randomly distributed into 3 groups (n=10): a) Control, b) 2% Chlorhexidine, and c) 5% Sodium Hypochlorite. Next, RelyX® ARC resin cement was used to cement the post. Each specimen resulted in samples from the three root thirds that were submitted to the pushout test (MPa) at 24 hours and 12 months. Bond strength values were analysed using the Kolmogorov-Smirnov, 3-way ANOVA and Tukey tests. The fracture mode of the pin was also analysed using stereomicroscopy. Result There were no significant differences between treatments at the immediate time (p=0.0644) or in the interaction of factors (p=0.1935). After one year, the experimental groups showed no significant differences in bond strength in relation to the control group, with the exception of the cervical third of the chlorohexidine group in which there was a significant loss of adhesion. As for the fracture mode, there was a predominance of the mixed type in all groups and thirds. Conclusion The use of chlorhexidine or hypochlorite provides neither benefits nor losses in the adhesive bond strength of fiberglass posts. However, there is an influence of the root thirds, with the worst bond strength in the apical third.
Collapse
Affiliation(s)
- Tainara CONTE
- UNIOESTE – Universidade Estadual do Oeste do Paraná, Brasil
| | | | | | | | | |
Collapse
|
8
|
Effect of Anatomical Customization of the Fiber Post on the Bond Strength of a Self-Adhesive Resin Cement. Int J Dent 2017; 2017:5010712. [PMID: 28785281 PMCID: PMC5530420 DOI: 10.1155/2017/5010712] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Accepted: 06/08/2017] [Indexed: 11/18/2022] Open
Abstract
AIM The aim of the study was to evaluate, by means of the push-out test, the effect of the anatomical customization of the fiber post on the bond strength of a self-adhesive resin cement. METHODS Twelve endodontically treated, human, upper central incisors were randomly divided into two groups (n = 6): control (glass fiber posts cemented with Relyx® U200) and customized (glass fiber posts anatomically customized with translucent composite resin cemented with Relyx U200). The roots were sectioned into three slices, cervical, middle, and apical, and photographed with a digital camera attached to a stereomicroscopic loupe. The images were analyzed by software, for evaluation of the cement line. The slices were subsequently submitted to the push-out test until the post had completely extruded, and the fracture mode was analyzed with a stereomicroscopic loupe. RESULTS The results showed significant differences between the groups in the different root thirds in relation to the area occupied by air bubbles (p < 0.05). Bond strength, when all the thirds are considered, was 8.77 ± 4.89 MPa for the control group and 16.96 ± 4.85 MPa for the customized group. CONCLUSION The customized group showed greater bond resistance than the control group and a more uniform cement layer.