1
|
Bueno FL, Badaró MM, Pagnano VO, Curylofo PA, Oliveira VDC, Macedo AP, Watanabe E, Paranhos HDFO, Silva-Lovato CH. Effect of disinfectants on multispecies biofilm, the physical and mechanical properties of polymethyl methacrylate, and the corrosion of cobalt chromium alloy. J Prosthet Dent 2024; 132:603.e1-603.e8. [PMID: 39019725 DOI: 10.1016/j.prosdent.2024.06.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 06/20/2024] [Accepted: 06/22/2024] [Indexed: 07/19/2024]
Abstract
STATEMENT OF PROBLEM The optimal disinfection protocol that controls adverse effects and promotes effective antimicrobial action on removable prostheses is unclear. PURPOSE This in vitro study investigated the effect of disinfectant solutions on the biological, physical, mechanical, and chemical properties of removable prosthesis materials. MATERIAL AND METHODS Specimens of polymethyl methacrylate (PMMA) and cobalt chromium (Co-Cr) alloy were immersed in distilled water (PMMA) or artificial saliva (Co-Cr) as the control and in 0.25% sodium hypochlorite (NaOCl0.25%), 0.5% chloramine T (CT0.5%), and 0.15% Triclosan (TR0.15%). The antibiofilm activity was evaluated by microbial load and cell metabolisms of the mixed biofilm. Physical (color change, sorption, solubility, and surface roughness), mechanical (hardness, flexural, and impact strength), and chemical (corrosion) properties were analyzed before and after simulating a 5-year immersion. Laser confocal microscopy, scanning electron microscopy (SEM), and dispersive energy spectroscopy (EDS) complemented the analyses. The data were analyzed by using the Mann-Whitney U test, Kruskal-Wallis with Dunn posttests, 1-way ANOVA, and repeated measures ANOVA (α=.05). RESULTS All solutions were effective against bacteria, but only NaOCl0.25% eliminated Candida spp. TR0.15%, and CT0.5% increased cell metabolisms. For interaction (time and solution), there was a reduction in PMMA hardness in the control and TR0.15%. Color, sorption, solubility, and flexural strength did not change. CT0.5% and TR0.15% were similar for impact resistance. CT0.5% caused the lowest roughness. NaOCl0.25% showed the greatest corrosive potential. Dark spots were seen under SEM in Co-Cr stored with NaOCl0.25% and TR0.15%. EDS indicated different proportions of oxygen, cobalt, chromium, and molybdenum. CONCLUSIONS NaOCl0.25% had the best antimicrobial action. CT0.5% and TR0.15% have potential. Hardness and roughness changes were clinically acceptable, and the other properties remained unchanged. All the solutions caused color changes. NaOCl0.25% was unsatisfactory for use with Co-Cr, CT0.5% was intermediate, and TR0.15% was suitable.
Collapse
Affiliation(s)
- Frank Lucarini Bueno
- PhD student, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Mauricio Malheiros Badaró
- Adjunct Professor, Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianopolis, SC, Brazil.
| | - Valéria Oliveira Pagnano
- Associate Professor, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Patrícia Almeida Curylofo
- PhD student, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Viviane de Cássia Oliveira
- Specialized Laboratory Technician, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Ana Paula Macedo
- Specialized Laboratory Technician, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Evandro Watanabe
- Associate Professor, Department of Restorative Dentistry, School of Dentistry of Ribeirao Preto, University of São Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Helena de Freitas Oliveira Paranhos
- Full Professor, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| | - Cláudia Helena Silva-Lovato
- Full Professor, Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirao Preto, University of Sao Paulo (USP), Ribeirao Preto, SP, Brazil
| |
Collapse
|
2
|
Muacevic A, Adler JR, Alshehri T, Abdelrahman Z. Cytotoxicity of Commercially Pure Titanium (cpTi), Silver-Palladium (Ag-Pd), and Nickel-Chromium (Ni-Cr) Alloys Commonly Used in the Fabrication of Dental Prosthetic Restorations. Cureus 2022; 14:e31679. [PMID: 36561578 PMCID: PMC9763053 DOI: 10.7759/cureus.31679] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2022] [Indexed: 11/21/2022] Open
Abstract
INTRODUCTION The longevity of dental implants is affected by the ability to avoid any hypersensitivity or corrosive reactions in the oral cavity. The aim of the current study was to evaluate the cytotoxic effect of commercially pure titanium (cpTi), silver-palladium (Ag-Pd), and nickel-chromium (Ni-Cr) on human gingival fibroblast (HGF). METHODS The sample size used was 10 discs from each alloy used with dimensions of 4x3mm. The HGF was derived from healthy patients subjected to gingivectomy procedures. Of the specimens, 50% were incubated in artificial saliva and the other half in Dulbecco's Modified Eagle medium (DMEM). The extract of each alloy in both media was collected and applied on HGF. After 24 hours the morphology of the HGF cells was examined to detect any apoptosis or cell death. Also, cell viability was evaluated by the use of a 3-(4,5-dimethyl thiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. Statistical analysis was performed using students' t-test and two-way ANOVA with a significance level of p<0.05. RESULTS In the case of morphological examination of HGF and MTT assessment, only cpTi alloy specimens didn't display any cytotoxic effect. Ni-Cr was the most cytotoxic alloy of the three. Also, MTT activities of all three alloys were decreased when they were incubated in artificial saliva. CONCLUSION cpTi exhibited the highest corrosion resistance in comparison to Ag-Pd and Ni-Cr alloys. Ag-Pd alloys showed acceptable resistance to corrosion that is due to the passivity effect. Also, artificial saliva increased the cytotoxic effect of the tested alloys more than DMEM.
Collapse
|
3
|
Hubkowska K, Kubisztal J, Pająk M, Łosiewicz B, Czerwiński A. Effect of the Alloying Metal on the Corrosion Resistance of Pd-Rich Binary Alloys with Pt, Rh, and Ru in Sulfuric Acid. MATERIALS (BASEL, SWITZERLAND) 2021; 14:2923. [PMID: 34071575 PMCID: PMC8198221 DOI: 10.3390/ma14112923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/17/2021] [Accepted: 05/25/2021] [Indexed: 11/17/2022]
Abstract
The paper presents the study of the corrosion resistance of electrodeposited Pd and its binary alloys with Pt, Rh, and Ru on a polycrystalline Au substrate. The corrosion resistance was tested in 0.5 M sulfuric acid at room temperature using potentiodynamic polarization and electrochemical impedance spectroscopy techniques. The morphology/composition and work function values were determined by scanning electron microscopy/energy-dispersive X-ray spectroscopy and scanning Kelvin probe, respectively. The obtained results revealed that the Pd electrode is the most resistant to corrosion, whereas the Pd-Ru electrode is the most susceptible to dissolution. It was found that the corrosion resistance of Pd-binary alloys decrease in the following order: Pd > Pd-Pt > Pd-Rh > Pd-Ru. This effect was assigned mainly to the difference in surface roughness factor of tested electrodes.
Collapse
Affiliation(s)
- Katarzyna Hubkowska
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland; (M.P.); (A.C.)
| | - Julian Kubisztal
- Institute of Materials Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 75 Pulku Piechoty 1A, 41-500 Chorzow, Poland; (J.K.); (B.Ł.)
| | - Małgorzata Pająk
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland; (M.P.); (A.C.)
| | - Bożena Łosiewicz
- Institute of Materials Engineering, Faculty of Science and Technology, University of Silesia in Katowice, 75 Pulku Piechoty 1A, 41-500 Chorzow, Poland; (J.K.); (B.Ł.)
| | - Andrzej Czerwiński
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland; (M.P.); (A.C.)
| |
Collapse
|
4
|
Sun D, Frankel GS, Brantley WA, Heshmati RH, Johnston WM. Electrochemical impedance spectroscopy study of corrosion characteristics of palladium-silver dental alloys. J Biomed Mater Res B Appl Biomater 2021; 109:1777-1786. [PMID: 33817975 DOI: 10.1002/jbm.b.34837] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 02/02/2021] [Accepted: 03/06/2021] [Indexed: 01/01/2023]
Abstract
Electrochemical impedance spectroscopy (EIS) has been used to obtain insight into corrosion processes for three Pd-Ag alloys, and compare their behavior with an Au-Pd alloy. Five specimens of each alloy received clinically-appropriate simulated porcelain-firing heat treatment. EIS testing was performed at ambient temperature, using 0.09% NaCl, 0.9% NaCl and Fusayama solutions. EIS data are presented as Bode plots. At the open-circuit potential (OCP), the data fit a modified Randles equivalent electrical circuit with a constant phase element (CPE), and the charge-transfer resistance (RCT ) and the two CPE parameters (CPE-T and CPE-P) were determined. The area-normalized capacitance of the double layer (Cdl ) was also calculated. The EIS data at two relevant elevated potentials in the passive range were also found to fit well a modified Randles equivalent circuit with different values for the charge transfer resistance and CPE parameters. At the OCP no significant effect on RCT was found for the alloys and electrolytes, and both alloy and electrolyte significantly affected CPE-P. In vitro corrosion was controlled by charge transfer and charge accumulation processes, and the behavior differed at the elevated potentials compared to the OCP. Significant effects were found for alloy, electrolyte, and alloy/electrolyte interaction on Cdl at the OCP. The EIS parameters at elevated potentials indicate that the Pd-Ag alloys should have satisfactory clinical corrosion resistance. The EIS analyses yielded information about in vitro corrosion of these alloys that cannot be obtained from potentiodynamic polarization testing.
Collapse
Affiliation(s)
- Desheng Sun
- Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - Gerald S Frankel
- Department of Materials Science and Engineering, College of Engineering, The Ohio State University, Columbus, Ohio, USA
| | - William A Brantley
- Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - Reza H Heshmati
- Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - William M Johnston
- Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
5
|
Liang Q, Ge S, Liu C, Quan X, Tan B, Xu K, Zou H. The effect of composite PHB coating on the biological properties of a magnesium based alloy. J Biomater Appl 2021; 35:1264-1274. [PMID: 33632006 DOI: 10.1177/0885328221998040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Magnesium alloys have been widely investigated as biodegradable cardiovascular temporal implants due to their better mechanical properties and biocompatibility, but the rapid degradation limited its application. In this study, the anodic oxidation-Cu structure was used to improve the adhesive strength and stability between poly-β-hydroxybutyrate (PHB) and magnesium alloys, and the effects of anodic oxidation magnesium alloys with copper film and PHB film (MACP) on human umbilical vein endothelial cells (HUVECs), blood compatibility and antibacterial properties were investigated in this research. As the result, the MACP structure had a stable structure and better corrosion resistance, and significant antibacterial properties. The coating would not affect the original excellent biocompatibility of the magnesium alloy. It was indicated that MACP was a potential surface modification strategy for vascular stents candidate material.
Collapse
Affiliation(s)
- Quan Liang
- Chongqing University of Technology, Chongqing, China
| | - Shuping Ge
- School of Chemistry and Chemical Engineering Chongqing University of Technology Chongqing, China
| | - Chenyu Liu
- Chongqing University of Technology, Chongqing, China
| | - Xuejun Quan
- Chongqing University of Technology, Chongqing, China
| | - Binbin Tan
- Department of Neurosurgery and Key Laboratory of Neurotrauma, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China
| | - Kai Xu
- China Coal Mining Group Chongqing Research Institute Co. LTD., Chongqing, China
| | - Hanyan Zou
- Chongqing Institute for Food and Drug Control, Chongqing, China
| |
Collapse
|
6
|
Tufekçi E, Mitchell JC, Olesik JW, Brantley WA, Monaghan P, Johnston WM. ICP-MS measurements of elemental release from two palladium alloys into a corrosion testing medium for different solution volumes and agitation conditions. J Prosthet Dent 2021; 128:522-528. [PMID: 33597079 DOI: 10.1016/j.prosdent.2020.12.038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 12/02/2020] [Accepted: 12/03/2020] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM The in vivo release of Pd from palladium alloys into the oral environment and sensitivity reactions by patients has been of concern. However, little information is available about the variation in elemental release from different palladium alloys. PURPOSE The purpose of this in vitro study was to compare the elemental release into a corrosion-testing medium from a high-palladium alloy (Freedom Plus, 78Pd-8Cu-5Ga-6In-2Au) and a Pd-Ag alloy (Super Star, 60Pd-28Ag-6In-5Sn) under different conditions. MATERIAL AND METHODS Alloys were cast into Ø12×1-mm-thick disks, subjected to simulated porcelain-firing heat treatment, polished, and ultrasonically cleaned in ethanol. Three specimens of each alloy were immersed for 700 hours in a solution for in vitro corrosion testing (ISO Standard 10271) that was maintained at 37 °C. Two solution volumes (125 mL and 250 mL) were used, and the solutions were subjected to either no agitation or agitation. Elemental compositions of the solutions were analyzed by using inductively coupled plasma-mass spectroscopy (ICP-MS). Concentrations of released elements from each alloy for the 2 solution volumes and agitation conditions were compared by using the restricted maximum likelihood estimation method with a 4-way repeated-measures ANOVA, the Satterwhite degrees of freedom method, a lognormal response distribution, and the covariance structure of compound symmetry. RESULTS For the 4 combinations of solution volume and agitation conditions, the mean amount of palladium released was 3 orders of magnitude less for the Pd-Ag alloy (0.009 to 0.017 μg/cm2 of alloy surface) compared with the Pd-Cu-Ga alloy (17.9 to 28.7 μg/cm2). Larger mean amounts of Sn, Ga, Ag, and In (0.29 to 0.39, 0.57 to 0.83, 0.71 to 1.08, and 0.91 to 1.25 μg/cm2, respectively) compared with Pd were released from the Pd-Ag alloy. Smaller amounts of Cu, Ga, and In (4.8 to 9.9, 5.9 to 12.8, and 4.2 to 9.5 μg/cm2, respectively) compared with Pd were released from the Pd-Cu-Ga alloy. The Ru released was much lower for the Pd-Ag alloy (0.002 μg/cm2) than the Pd-Cu-Ga alloy (0.032 to 0.053 μg/cm2). Statistically significant differences (P<.001) in elemental release were found for the factors of alloy and element and the alloy×element interaction. Significant differences were found for the solution volume (P=.022), solution volume×element interaction (P=.022), and alloy×solution volume×element interaction (P=.004). No significant effect was found for agitation condition. CONCLUSIONS The relative amounts of released elements from each alloy were not proportional to the relative amounts in the composition. The amounts of Pd and Ga released from the Pd-Cu-Ga alloy were consistent with the breakdown of a Pd2Ga microstructural phase and perhaps some dissolution of the palladium solid solution matrix. Precipitates, rather than the palladium solid solution matrix, appeared to undergo greater dissolution in the Pd-Ag alloy. The Pd-Ag alloy should have lower risk of adverse biological reactions than the Pd-Cu-Ga alloy.
Collapse
Affiliation(s)
- Eser Tufekçi
- Professor, Department of Orthodontics, Virginia Commonwealth University, School of Dentistry, Richmond, Va; Formerly, Section of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
| | - John C Mitchell
- Professor and Associate Dean, College of Dental Medicine, Midwestern University, Glendale, Ariz; Formerly, Department of Geological Sciences, The Ohio State University, Columbus, Ohio
| | - John W Olesik
- Research Scientist, Trace Element Research Laboratory, School of Earth Sciences, The Ohio State University, Columbus, Ohio
| | - William A Brantley
- Professor Emeritus, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.
| | - Peter Monaghan
- Sherman Dental Associates, Evanston, Ill; Formerly, Section of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
| | - William M Johnston
- Professor Emeritus, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
7
|
Mechanical Durability of Engineered Superhydrophobic Surfaces for Anti-Corrosion. COATINGS 2018. [DOI: 10.3390/coatings8050162] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|