1
|
Bandiaky ON, Clouet R, Le Bars P, Soueidan A, Le Guehennec L. Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study. J Prosthodont 2023; 32:846-853. [PMID: 36627825 DOI: 10.1111/jopr.13639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 12/12/2022] [Accepted: 12/18/2022] [Indexed: 01/12/2023] Open
Abstract
PURPOSE This study aimed to compare the marginal and internal fit of five-unit zirconia-based fixed dental prostheses (FDPs) fabricated using digital scans and conventional impressions. MATERIALS AND METHODS Nine master models with three zirconia abutments were scanned with an intraoral scanner (test group), and nine conventional impressions (control group) of these same models were also made. The stone casts from these impressions were scanned with a laboratory extraoral scanner (D700, 3Shape, Copenhagen, Denmark). A total of 18 five-unit zirconia-based FDP frameworks (test group, n = 9; control group, n = 9) were manufactured. Marginal and internal fit (in μm) were evaluated using the replica method under micro-computed tomography. Analysis of variance (one-way ANOVA) and Kruskal-Wallis tests were used to compare continuous variables across two groups. A level of p < 0.05 was accepted as statistically significant. RESULTS The mean ± standard deviation of the marginal fit was 95.03 ± 12.74 μm in the test group and 106.02 ± 14.51 μm in the control group. The lowest marginal mean value was observed in the test group, with a statistically significant difference compared to the control group (F = 14.56, p < 0.05). The mean ± standard deviation of the internal fit was 103.61 ± 9.32 and 106.38 ± 7.64 μm, respectively, in the test and control groups, with no statistically significant difference (F = 1.56, p > 0.05). The mean values of both groups were clinically acceptable. CONCLUSIONS The five-unit zirconia-based FDPs fabricated with digital scans showed better fit than those in the conventional impression group. Within the limitations of this study, these results are encouraging, and continued progress in the digital field should allow for more accurate long-span restorations.
Collapse
Affiliation(s)
- Octave Nadile Bandiaky
- Nantes University, Oniris, Univ Angers, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, Nantes, France
| | - Roselyne Clouet
- Department of Prosthetic Dentistry, Nantes University, CHU Nantes, Nantes, France
| | - Pierre Le Bars
- Department of Prosthetic Dentistry, Nantes University, CHU Nantes, Nantes, France
| | - Assem Soueidan
- Department of Periodontology, Nantes University, Oniris, Univ Angers, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, Nantes, France
| | - Laurent Le Guehennec
- Department of Prosthodontics, Nantes University, Oniris, Univ Angers, CHU Nantes, INSERM, Regenerative Medicine and Skeleton, Nantes, France
| |
Collapse
|
2
|
Maravić T, Mazzitelli C, Mancuso E, Del Bianco F, Josić U, Cadenaro M, Breschi L, Mazzoni A. Resin composite cements: Current status and a novel classification proposal. J ESTHET RESTOR DENT 2023; 35:1085-1097. [PMID: 36924395 DOI: 10.1111/jerd.13036] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 03/18/2023]
Abstract
OBJECTIVES Currently, a classification of resin cements that includes relatively recently formulated ("universal") cements is lacking. Furthermore, the terminology used to define different resin cements in the scientific reports is inconsistent. Accordingly, this work aims to: (i) propose a novel classification of resin composite cements; (ii) disambiguate the term "universal cements" and (iii) present an overview of the properties of these cements. METHODS An analysis of peer-reviewed literature (PubMed search), as well as market research on definitive resin composite cements were performed. RESULTS A tendency toward simplified and versatile luting materials was observed both in the scientific literature and on the dental market with the advent of self-adhesive/one-step resin cements. However, additional priming procedures were necessary to improve their bonding performance in certain clinical situations. Hence, several cements that can be applied both in adhesive and self-adhesive mode were introduced. These cements are associated with a universal adhesive resin, that can be used as a tooth and/or restorative material primer, without the need for other priming systems, regardless of the substrate. These systems should be considered truly universal. Therefore, we hereby suggested a new classification of resin-based cements: (1) adhesive/multi-step; (2) self-adhesive/one-step; (3) universal cements (one- or multi-step). Despite promising in vitro results, clinical trials and long-track laboratory studies are necessary to confirm the reliability of the universal cements. CONCLUSIONS This review presented the current advances in the field of resin-based cements, which are reflected in the proposed classification. The term "universal cement" was disambiguated, which will help standardize the terminology used in published research. CLINICAL SIGNIFICANCE The classification of resin-based cements and a better understanding of the proper terminology will help standardize the terminology in published research, as well as improve the understanding of the clinical practitioners of the different indications and possible modalities of use of the available cements.
Collapse
Affiliation(s)
- Tatjana Maravić
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Edoardo Mancuso
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Federico Del Bianco
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Uroš Josić
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Milena Cadenaro
- Department of Medical Sciences, University of Trieste, Trieste, Italy
- Department of Surgery, Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna - Alma Mater Studiorum, Bologna, Italy
| |
Collapse
|
3
|
Shihabi S, Chrcanovic BR. Clinical outcomes of tooth-supported monolithic zirconia vs. porcelain-veneered zirconia fixed dental prosthesis, with an additional focus on the cement type: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:5755-5769. [PMID: 37626273 PMCID: PMC10560185 DOI: 10.1007/s00784-023-05219-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 08/15/2023] [Indexed: 08/27/2023]
Abstract
PURPOSE To compare the failure rates and the prevalence of technical complications between full-coverage tooth-supported monolithic zirconia (MZ) and porcelain-veneered zirconia (PVZ) fixed dental prosthesis, based on a systematic literature review. METHODS An electronic search was performed in three databases, supplemented by hand searching. Several statistical methods were used. RESULTS Seventy-four publications reported 6370 restorations (4264 PVZ; 2106 MZ; 8200 abutment teeth; 3549 patients), followed up until 152 months. A total of 216 prostheses failed, and survival was statistically significant different between groups. PVZ had higher occurrence of complications than MZ; the difference was especially greater for either minor or major chipping. The difference in prevalence of either minor or major chipping was statistically significant for PVZ prostheses between cementation with glass ionomer and adhesive resin cement (higher), adhesive resin and resin-modified glass ionomer cement (RMGIC, higher), and between RMGIC (higher) and glass ionomer cement. For MZ the difference was significant only for minor chipping between RMGIC (higher) and adhesive resin cement. Abutment teeth to PVZ prostheses more often lost vitality. Decementation was not observed with RMGIC. Air abrasion did not seem to clinically decrease the decementation risk. The 5-year difference in the occurrence of minor or major chipping between MZ and PVZ prostheses was statistically significant, but nor for catastrophic fracture. CONCLUSION Tooth-supported PVZ prostheses present higher failure and complication rates than MZ prosthesis. The difference in complications is striking when it comes to chipping. CLINICAL RELEVANCE Awareness of the outcome differences between different types of zirconia prostheses is important for clinical practice.
Collapse
Affiliation(s)
| | - Bruno Ramos Chrcanovic
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21 Malmö, Sweden
| |
Collapse
|
4
|
Breschi L, Josic U, Maravic T, Mancuso E, Del Bianco F, Baldissara P, Mazzoni A, Mazzitelli C. Selective adhesive luting: A novel technique for improving adhesion achieved by universal resin cements. J ESTHET RESTOR DENT 2023; 35:1030-1038. [PMID: 36971211 DOI: 10.1111/jerd.13037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/22/2022] [Accepted: 03/08/2023] [Indexed: 03/29/2023]
Abstract
OBJECTIVE We aimed to introduce the concept of "Selective adhesive luting-SAL" which is explained through clinical steps and supported by preliminary laboratory evidence. CLINICAL CONSIDERATIONS Cementation with rubber dam is difficult to perform in case of short abutment teeth and/or subgingival crown margins. By means of universal resin cements/universal adhesive systems, which can be employed in self-adhesive as well as adhesive luting procedures, this paper presents a novel technique allowing clinicians to perform reliable cementation where rubber dam isolation is difficult. The SAL technique entails the application of a universal adhesive system only on easily accessible abutment surfaces, enabling simultaneous adhesive and self-adhesive luting in different portions of the abutment. The SAL clinical workflow is explained through prosthodontic rehabilitation of maxillary right central incisor affected by microdontia and restored with a lithium-disilicate crown. Furthermore, our laboratory microshear bond strength study supports the rationale behind SAL application demonstrating higher bond strength even when the adhesive resin is placed only on one portion of the cementation substrate. CLINICAL SIGNIFICANCE This article advocates the application of SAL technique in clinical situations where effective adhesive luting is uncertain, since it can improve the adhesion between the tooth and universal resin cements.
Collapse
Affiliation(s)
- Lorenzo Breschi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Uros Josic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Tatjana Maravic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Edoardo Mancuso
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Federico Del Bianco
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Paolo Baldissara
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Annalisa Mazzoni
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
5
|
Abd Alraheam I, Al-Asmar A, Hasan N, Asoleihat F, Alkayed A. Clinical evaluation of cemented and adhesively resin-bonded monolithic and partially layered zirconia and lithium disilicate crowns. Saudi Dent J 2023; 35:508-514. [PMID: 37520593 PMCID: PMC10373076 DOI: 10.1016/j.sdentj.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 04/03/2023] [Accepted: 04/10/2023] [Indexed: 08/01/2023] Open
Abstract
Purpose Zirconia and lithium disilicate crowns are very popular dental restorations. The cement type and layering technique used can profoundly affect the clinical performance of these crowns.This retrospective study is designed to investigate the success rate of cemented and adhesively bonded monolithic and partially layered zirconia and lithium disilicate crowns placed in faculty practice settings. Materials and Methods Patients who had received zirconia or lithium disilicate crowns at the faculty practice were invited for clinical examination. The examiner used the modified United States Public Health Service (MUSPHS) evaluation criteria to evaluate the crowns. The crowns were either glass ionomer cemented zirconia (GIC-Zr), resin-bonded zirconia (Adh-Zr), or resin-bonded lithium disilicate (Adh-LD). The crowns were also divided into monolithic and layered groups. Inferential analysis was used to examine the differences through bivariate analysis using t-testing and one-way ANOVA. Results Thirty-five patients, with a combined total of 218 single crowns, agreed to participate in the study. No statistically significant differences in the quality outcome variables considered were found between the groups, except for marginal adaptation, where Adh-Zr achieved significantly higher scores compared to GIC-Zr and Adh-LD. Layered zirconia and lithium disilicate crowns have significantly higher quality outcomes in terms of anatomic form, marginal adaptation, and color match compared to monolithic zirconia and lithium disilicate crowns. Conclusions Conventionally cemented zirconia and adhesively bonded zirconia and lithium disilicate crowns are reliable treatment options with high short-term success rates. Clinical studies with longer follow-up times are needed to investigate their long-term success rates.
Collapse
Affiliation(s)
- Islam Abd Alraheam
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Aya Al-Asmar
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Noor Hasan
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Firas Asoleihat
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| | - Awni Alkayed
- Department of Restorative Dentistry, University of Jordan, Amman, Jordan
| |
Collapse
|
6
|
Pyo SW, Park K, Daher R, Kwon HB, Han JS, Lee JH. Comparison of the clinical outcomes of resin-modified glass ionomer and self-adhesive resin cementations for full-coverage zirconia restorations. J Dent 2023:104558. [PMID: 37230241 DOI: 10.1016/j.jdent.2023.104558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 05/17/2023] [Accepted: 05/22/2023] [Indexed: 05/27/2023] Open
Abstract
OBJECTIVES Both resin-modified glass ionomer cement (RMGIC) and self-adhesive resin cement (SAC) may be suitable for cementation of full-coverage zirconia restorations. This retrospective study aimed to investigate the clinical outcomes of zirconia-based restorations cemented with RMGIC and compare them with those cemented with SAC. METHODS Cases of full-coverage zirconia-based restorations cemented with either RMGIC or SAC between March 2016 and February 2019 were evaluated in this study. The clinical outcomes of the restorations were analyzed according to the type of cement used. In addition, cumulative success and survival rates were evaluated according to the cement and abutment types. Non-inferiority, Kaplan-Meier, and Cox hazard tests were conducted (α=.05). RESULTS A total of 288 full-coverage zirconia-based restorations (natural teeth, 157; implant restorations, 131) were analyzed. Loss of retention occurred in only one case; a single-unit implant crown cemented with RMGIC, which decemented 4.25 years post-restoration. RMGIC was non-inferior to SAC in terms of loss of retention (<5%). For single-unit natural tooth restorations, the four-year success rates in the RMGIC and SAC groups were 100% and 95.65%, respectively (p=.122). For single-unit implant restorations, the four-year success rates in the RMGIC and SAC groups were 95.66% and 100%, respectively (p=.365). The hazard ratios of all the predictor variables, including cement type, were not significant (p>.05). CONCLUSIONS Cementation of full-coverage zirconia restorations of both natural teeth and implants using RMGIC and SAC yields satisfactory clinical outcomes. Furthermore, RMGIC is non-inferior to SAC in terms of cementation success. CLINICAL SIGNIFICANCE Cementation with RMGIC or SAC for full-coverage zirconia restorations has favorable clinical outcomes in both natural teeth and implants. Both RMGIC and SAC have advantages in the cementation of full-coverage zirconia restorations to abutments with favorable geometries.
Collapse
Affiliation(s)
- Se-Wook Pyo
- Clinical Assistant Professor, Department of Prosthodontics, Gangnam Severance Hospital, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Koungjin Park
- Graduate Student, Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - René Daher
- Senior Lecturer, Division of Cariology and Endodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Ho-Beom Kwon
- Dean and Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jung-Suk Han
- Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jae-Hyun Lee
- Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.; Program Director and Assistant Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea..
| |
Collapse
|
7
|
Rauch A, Lorenz L, Reich S, Hahnel S, Schmutzler A, Schierz O. Long-term survival of monolithic tooth-supported lithium disilicate crowns fabricated using a chairside approach: 15-year results. Clin Oral Investig 2023:10.1007/s00784-023-05023-0. [PMID: 37083987 DOI: 10.1007/s00784-023-05023-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Accepted: 04/11/2023] [Indexed: 04/22/2023]
Abstract
OBJECTIVES To investigate the clinical performance of chairside fabricated tooth-supported posterior single crowns from lithium disilicate ceramic. MATERIALS AND METHODS Thirty-four crowns (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) were inserted between 2006 and 2007 and again evaluated after 15 years. Survival and success rates were calculated according to Kaplan-Meier, and the quality of the crowns was evaluated by using modified United States Public Health (USPHS) criteria. RESULTS Twenty-two crowns were available for recall; six patients were defined as dropouts. The mean observation period was 15.2 years (± 0.2). Six failures occurred (1 technical/5 biological) resulting in a survival rate of 80.1%. The success rate was 64.2%. The roughness of the crowns increased (p = 0.021) and the majority of adhesive gaps were discolored (p = 0.001) in comparison to baseline. The color, tooth, and crown integrity remained stable over the follow-up period (p ≥ 0.317). CONCLUSION The fabrication of tooth-supported lithium disilicate crowns using a chairside approach yielded acceptable long-term survival and success rates. Due to discoloration, the long-term use of dual-cure self-adhesive resin cements might result in unpleasing esthetic results. CLINICAL RELEVANCE The performance of posterior lithium disilicate single crowns revealed excellent to good clinical quality and an acceptable number of events after 15 years of clinical service.
Collapse
Affiliation(s)
- Angelika Rauch
- Department of Dental Prosthetics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
- Department of Prosthodontics and Materials Science, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany.
| | - Lea Lorenz
- Department of Prosthodontics and Materials Science, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany
| | - Sven Reich
- Department of Prosthodontics and Biomaterials, Centre of Implantology, Faculty of Medicine, RWTH University Hospital, Pauwellsstr. 30, 52074, Aachen, Germany
| | - Sebastian Hahnel
- Department of Dental Prosthetics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Anne Schmutzler
- Department of Dental Prosthetics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Oliver Schierz
- Department of Prosthodontics and Materials Science, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany
| |
Collapse
|
8
|
Alenezi A, Alkhudhayri O, Altowaijri F, Aloufi L, Alharbi F, Alrasheed M, Almutairi H, Alanazi A, Yehya M, Al Asmari D. Secondary caries in fixed dental prostheses: Long-term clinical evaluation. Clin Exp Dent Res 2023; 9:249-257. [PMID: 36433888 PMCID: PMC9932257 DOI: 10.1002/cre2.696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 11/15/2022] [Accepted: 11/18/2022] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVES Even with excellent fixed dental prostheses (FDPs), there will be a substantial risk of biological complications, such as caries, if proper oral hygiene is not maintained. This study aimed to evaluate the risks of developing secondary caries with FDPs in relation to the patient oral hygiene status. MATERIAL AND METHODS Clinical and radiographic examinations were performed for patients to collect data related to their FDP complications and oral hygiene status. The main clinical parameter analyzed was secondary caries. Complications such as a fracture, debonding, or the need for endodontic therapy were also analyzed. The interval survival rate and the cumulative survival rate of FDPs from the time of treatment to the time of follow-up were analyzed. RESULTS A total of 423 patients (with a total of 1116 FDPs) were examined in this study, with a mean age of 43.7 years and a mean follow-up time of 7 years. Regarding complications, secondary caries was detected in 94 FDPs (8.4%), fracture (or chipping) in 85 (7.6%) cases, need for endodontic treatment in 42 cases (3.7%), and debonding in four (0.3%) cases. Secondary caries was found in nine out of 219 FDPs (4%) in patients with good oral hygiene, 35 out of 634 FDPs (5.5%) in patients with fair oral hygiene, and 50 out of 272 FDPs (18.4%) in patients with poor oral hygiene (p ≤ .001). CONCLUSIONS Good oral hygiene has a great influence on reducing the risk of secondary caries in patients with FDPs. The occurrence of secondary caries is a common complication in patients with poor oral hygiene.
Collapse
Affiliation(s)
- Ali Alenezi
- Department of Prosthodontics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Omar Alkhudhayri
- Interns' Clinics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Fahad Altowaijri
- Interns' Clinics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Lina Aloufi
- Interns' Clinics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Fatimah Alharbi
- Interns' Clinics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Maha Alrasheed
- Interns' Clinics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Hind Almutairi
- Interns' Clinics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Abdulltif Alanazi
- Department of Restorative DentistryPrince Sultan Military Medical CityRiyadhSaudi Arabia
| | - Mohammed Yehya
- Department of Prosthodontics, College of DentistryQassim UniversityBuraydahSaudi Arabia
| | - Dhafer Al Asmari
- Department of Periodontology, College of DentistryQassim UniversityBuraydahSaudi Arabia
| |
Collapse
|
9
|
Schmitter M, Bömicke W, Behnisch R, Lorenzo Bermejo J, Waldecker M, Rammelsberg P, Ohlmann B. Ceramic Crowns and Sleep Bruxism: First Results from a Randomized Trial. J Clin Med 2022; 12:jcm12010273. [PMID: 36615073 PMCID: PMC9821737 DOI: 10.3390/jcm12010273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/21/2022] [Accepted: 12/27/2022] [Indexed: 12/31/2022] Open
Abstract
Background: This randomized clinical trial was conducted to assess whether sleep bruxism (SB) is associated with an increased rate of technical complications (ceramic defects) in lithium disilicate (LiDi) or zirconia (Z) molar single crowns (SCs). Methods: Adult patients were classified as affected or unaffected by SB based on structured questionnaires, clinical signs, and overnight portable electromyography (BruxOff) and block randomized into four groups according to SB status and crown material (LiDi or Z): LiDi-SB (n = 29), LiDi-no SB (n = 24), Z-SB (n = 23), and Z-no SB (n = 27). Differences in technical complications (main outcome) and survival and success rates (secondary outcomes) one year after crown cementation were assessed using Fisher’s exact test with significance level α = 0.05. Results: No technical complications occurred. Restoration survival rates were 100% in the LiDi-SB and LiDi-no SB groups, 95.7% in the Z-SB group, and 96.3% in the Z-no SB group (p > 0.999). Success rates were 96.6% in the LiDi-SB group, 95.8% in the LiDi-no SB group (p > 0.999), 91.3% in the Z-SB group, and 96.3% in the Z-no SB group (p ≥ 0.588). Conclusions: With a limited observation time and sample size, no effect of SB on technical complication, survival, and success rates of molar LiDi and Z SCs was detected.
Collapse
Affiliation(s)
- Marc Schmitter
- Department of Prosthodontics, University of Würzburg, Pleicherwall 2, 97070 Würzburg, Germany
| | - Wolfgang Bömicke
- Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
- Correspondence: ; Tel.: +49-622-156-6052
| | - Rouven Behnisch
- Institute of Medical Biometry, University of Heidelberg, Im Neuenheimer Feld 130.3, 69120 Heidelberg, Germany
| | - Justo Lorenzo Bermejo
- Institute of Medical Biometry, University of Heidelberg, Im Neuenheimer Feld 130.3, 69120 Heidelberg, Germany
| | - Moritz Waldecker
- Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Peter Rammelsberg
- Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Brigitte Ohlmann
- Department of Prosthodontics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| |
Collapse
|
10
|
Benli M, Turkyilmaz I, Martinez JL, Schwartz S. Clinical performance of lithium disilicate and zirconia CAD/CAM crowns using digital impressions: A systematic review. Prim Dent J 2022; 11:71-76. [PMID: 36533368 DOI: 10.1177/20501684221132941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
PURPOSE The purpose of this systematic review was to compare the clinical performance of lithium disilicate (LDS) and zirconia (Z) single crowns manufactured by computer-aided design/computer-aided manufacturing (CAD/CAM) systems using intraoral optical scanners (IOS). MATERIALS AND METHODS An electronic search for articles published between January 2012 and January 2022 in the English language was performed with the Medline/Pubmed database under the guidelines of Preferred Reporting Items for Systemic Reviews and Meta-analysis (PRISMA). The specific search terms used were "zirconia", "lithium disilicate", "CAD/CAM", "intraoral optical scanner", and "survival". RESULTS The initial electronic search resulted in 278 articles. Most of the resulting articles were excluded, six clinical studies addressing the clinical outcomes of Z and LDS crowns fitted the inclusion criteria and were selected for review. Of these six studies, three were randomised controlled trials, two were retrospective studies, and one was a prospective study. To quantify the clinical performance of the crowns several parameters were recorded, including fractures, endodontic complications, periodontal complications, technical complications, aesthetic complications, and biological complications. It was noted that the most common technical complication of Z and LDS crowns was chipping at a rate of 1.4% and 5% respectively. Regarding Z crowns, aesthetic concerns were the most frequently observed complication. CONCLUSION The outcomes of this systematic review indicate that Z and LDS crowns display a similar incidence of periodontal and endodontic complications when compared to metal-ceramic crowns, suggesting that these all-ceramic materials are viable alternatives. The incidence of chipping was higher in LDS crowns compared to other materials, while Z crowns were inferior in terms of aesthetics.
Collapse
Affiliation(s)
- Merve Benli
- Researcher, University of Pittsburgh, School of Dental Medicine, Department of Oral Biology, Pittsburgh, USA; Assistant Professor, Istanbul University, School of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | - Ilser Turkyilmaz
- Professor, New York University College of Dentistry, Department of Prosthodontics, New York, USA
| | | | | |
Collapse
|
11
|
A Review on Risk Management of Coronavirus Disease 19 (COVID-19) Infection in Dental Practice: Focus on Prosthodontics and All-Ceramic Materials. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4030028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: A novel β-coronavirus infection (COVID-19) was first detected in Wuhan city, spreading rapidly to other countries and leading to a pandemic. Dental professionals and patients are exposed to a high risk of COVID-19 infection, particularly in the prosthodontic practice, because of the bio-aerosol produced during teeth preparation with dental handpieces and the strict contact with oral fluids during impression making. This paper aimed to provide an overview to limit the risk of transmission of COVID-19 infections during prosthetic procedures in dental offices. Methods: An electronic search was conducted on the electronic databases of PubMed/Medline, Google Scholar, Embase, Scopus, Dynamed, and Open Grey with the following queries: (COVID-19) AND/OR (SARS-CoV-2) AND/OR (Coronavirus) AND/OR (contaminated surface) AND/OR (cross-infection) AND/OR (Prosthodontics) AND/OR (dental ceramic) AND/OR (glass-ceramic). A manual search was performed as well. Results: From the 1023 collected records, 32 papers were included. Conclusions: Dental offices are at high risk of spreading SARS-CoV-2 infection due to the close contact with patients and continuous exposure to saliva during dental procedures. Therefore, pre-check triages via telephone, decontamination, the disinfection of impressions, the sterilization of scanner tips, and the use of specific personal protective equipment, dental high-speed handpieces with dedicated anti-retraction valves, and effective mouthwashes are strongly recommended.
Collapse
|
12
|
Harouny R, Hardan L, Harouny E, Kassis C, Bourgi R, Lukomska-Szymanska M, Kharouf N, Ball V, Khairallah C. Adhesion of Resin to Lithium Disilicate with Different Surface Treatments before and after Salivary Contamination—An In-Vitro Study. Bioengineering (Basel) 2022; 9:bioengineering9070286. [PMID: 35877337 PMCID: PMC9312288 DOI: 10.3390/bioengineering9070286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/15/2022] [Accepted: 06/23/2022] [Indexed: 11/25/2022] Open
Abstract
The salivary contamination occurring at the try-in procedures of lithium disilicate (LDS) can jeopardize their bond strength. Various laboratory reports have concluded that applying 37% phosphoric acid (H3PO4) could be considered as a predictable way of removing salivary contaminants. An experimental method that consists of sealing the intaglio of the ceramic restorations with a layer of cured adhesive could allow consequent time saving for dental practitioners. It is, besides, necessary to establish an optimal decontamination protocol. Hence, this study aimed to determine the most efficient surface treatment, before and after salivary contamination, by comparing the adhesion between resin and LDS. In order to do so, five groups of ten specimens (n = 10) each underwent the different types of surface treatments before bonding, followed by 2500 cycles in the thermocycler. A shear bond strength (SBS) test was then conducted on a universal testing machine (YLE GmbH Waldstraße Bad König, Germany), followed by a fracture-type analysis on an optical microscope (Olympus BX53, Shinjuku, Tokyo, Japan). Statistical analysis was set with a level of significance of α = 0.05. The surface treatment significantly affected the SBS results. The decontamination with HF (12.59 ± 2.71 MPa) and H3PO4 (13.11 ± 1.03 MPa) obtained the highest values, silanizing only before contamination obtained intermediate values (11.74 ± 3.49 MPa), and silanizing both before and after the salivary contamination (10.41 ± 2.75 MPa) along with applying a bonding agent before contamination (9.65 ± 1.99 MPa) resulted in the lowest values. In conclusion, H3PO4 proved to be efficient, thus, allowing the practitioner to avoid the clinical use of HF; it can, therefore, be considered as a valid alternative. Presilanization and resilanization of specimens, along with applying a bonding agent before contamination, did not yield satisfying results.
Collapse
Affiliation(s)
- Ryan Harouny
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (R.H.); (L.H.); (E.H.); (C.K.); (R.B.); (C.K.)
- Craniofacial Research Laboratory, Division of Biomaterials, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (R.H.); (L.H.); (E.H.); (C.K.); (R.B.); (C.K.)
| | - Elie Harouny
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (R.H.); (L.H.); (E.H.); (C.K.); (R.B.); (C.K.)
| | - Cynthia Kassis
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (R.H.); (L.H.); (E.H.); (C.K.); (R.B.); (C.K.)
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (R.H.); (L.H.); (E.H.); (C.K.); (R.B.); (C.K.)
| | | | - Naji Kharouf
- Department of Endodontics, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France;
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Vincent Ball
- Department of Endodontics, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France;
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
- Correspondence:
| | - Carlos Khairallah
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (R.H.); (L.H.); (E.H.); (C.K.); (R.B.); (C.K.)
| |
Collapse
|
13
|
Prospective Clinical Evaluation of Posterior Third-Generation Monolithic Zirconia Crowns Fabricated with Complete Digital Workflow: Two-Year Follow-Up. MATERIALS 2022; 15:ma15020672. [PMID: 35057389 PMCID: PMC8780337 DOI: 10.3390/ma15020672] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/06/2022] [Accepted: 01/13/2022] [Indexed: 12/11/2022]
Abstract
Clinical studies on the behavior of posterior translucent monolithic zirconia restorations are lacking. We assessed the clinical outcome and survival rate of posterior third-generation monolithic zirconia crowns over a 2-year period. A total of 24 patients, requiring 30 posterior full-contour restorations were selected. All abutments were scanned, and crowns were milled and cemented with a self-adhesive dual cure cement. Crowns were assessed using the California Dental Association’s criteria. Gingival status was assessed by evaluating the gingival index, plaque index, periodontal probing depth of the abutments and control teeth, and the margin index of the abutment teeth. Statistical analyses were performed using the Friedman and the Wilcoxon signed-rank tests. During the 2-year follow-up, no biological or mechanical complications were observed, and the survival and success rate was 100%. All restorations ranked as satisfactory throughout the follow-up period. The gingival index and plaque index were worse at the end of the 2-year follow-up. The margin index was stable during the 2 years of clinical service. No significant differences were recorded in periodontal parameters between crowns and control teeth. Third-generation monolithic zirconia could be a reliable alternative to posterior metal–ceramic and second-generation monolithic zirconia posterior crowns.
Collapse
|
14
|
Comparison of Bond Strength in the Different Class of Resin Cements to Cast and CAD/CAM Co-Cr Alloys. Int J Dent 2022; 2021:7843979. [PMID: 34987585 PMCID: PMC8720600 DOI: 10.1155/2021/7843979] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 11/13/2021] [Indexed: 11/17/2022] Open
Abstract
Objectives Despite the widespread use of resin cements in cementing dental restorations, their bond strength to CAD/CAM base metal alloys is not widely studied. This study aimed to evaluate the microshear bond strength (μSBS) between cobalt-chrome (Co-Cr) alloys fabricated using casting or CAD/CAM methods with three types of resin cements. Materials and Methods Fifty Co-Cr blocks were prepared with CAD/CAM or casting technique. Specimens were divided using primer or not and bonded to three types of resin cements: Panavia F2, RelyX Unicem, and Duo-Link. The differences between the mean μSBS values were analyzed using the two-way ANOVA test and Tukey analysis (α = 0.05). The mode of failure was evaluated using a stereomicroscope. In addition, the specimens were examined by scanning electron microscopy (SEM) based on two received signals: backscattered electrons (SEB) and secondary electrons (SEs). One intact alloy specimen in each group was analyzed by energy-dispersive X-ray spectroscopy (EDX). Results Most of the specimens in the no-primer group were prematurely debonded. Statistical analyses showed that the interaction between the alloy substrate and cement type was significant (p=0.001). The bond strength of Panavia F2 was significantly higher than Duo-Link in the CAD/CAM group (p=0.001). SEM evaluation confirmed the difference in grain structures, while EDX showed no remarkable difference in the chemical composition of the alloy substrates. Conclusion Alloy fabrication technique may influence the bond strength of resin cements. In the CAD/CAM group, cement containing MDP molecules exhibited higher strength than the etch-and-rinse one.
Collapse
|
15
|
Josic U, Sebold M, Lins RBE, Savovic J, Mazzitelli C, Maravic T, Mazzoni A, Breschi L. Does immediate dentin sealing influence postoperative sensitivity in teeth restored with indirect restorations? A systematic review and meta-analysis. J ESTHET RESTOR DENT 2021; 34:55-64. [PMID: 34859939 PMCID: PMC9300029 DOI: 10.1111/jerd.12841] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/21/2021] [Accepted: 11/09/2021] [Indexed: 12/22/2022]
Abstract
Objective This study comprehensively reviewed clinical trials that investigated the effect of immediate dentin sealing (IDS) technique on postoperative sensitivity (POS) and clinical performance of indirect restorations. Materials and methods The systematic review was conducted according to the preferred reporting items for systematic reviews and meta‐analyses statement, and was guided by the PICOS strategy. Clinical trials in which adult patients received at least one indirect restoration cemented with IDS approach and one restoration cemented following the delayed dentin sealing (DDS) were considered. Results Following title screening and full‐text reading, four studies met the inclusion criteria and were included for qualitative synthesis, while two studies were selected for quantitative synthesis. According to Risk of bias‐2 tool, two studies were classified as “some concerns” for the outcome POS. No statistically significant differences were found between teeth restored with indirect restorations using the IDS and DDS approach for POS (p > 0.05), neither at the baseline (very low certainty of evidence according to GRADE) nor after 2 years of follow‐up (low certainty of evidence according to GRADE). Conclusion There is low‐certainty evidence that IDS does not reduce POS in teeth restored with indirect restorations. Clinical significance There is no clinical evidence to favor IDS over DDS when restoring teeth with indirect restorations.
Collapse
Affiliation(s)
- Uros Josic
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna.,Clinic for Pediatric and Preventive Dentistry, School of Dental Dedicine, University of Belgrade, Belgrade, Serbia
| | - Maicon Sebold
- Department of Restorative Dentistry, Operative Dentistry Devision, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | - Rodrigo B E Lins
- Department of Restorative Dentistry, Operative Dentistry Devision, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil.,Dentistry Course, State University of Paraiba, Araruna, Brazil
| | - Jelena Savovic
- Population Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK
| | - Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna
| | - Tatjana Maravic
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna
| |
Collapse
|
16
|
Indergård JA, Skjold A, Schriwer C, Øilo M. Effect of cementation techniques on fracture load of monolithic zirconia crowns. Biomater Investig Dent 2021; 8:160-169. [PMID: 34693294 PMCID: PMC8530494 DOI: 10.1080/26415275.2021.1990764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Aim The aim of this study was to evaluate the effect of cement on the fracture load of monolithic zirconia crowns with different yttria content (3 and 5 mol%). Methods A total of 62 monolithic zirconia crowns, 40 3Y-zirconia crowns (Prettau® Zirconia, Zirkonzahn) and 22 5Y-zirconia crowns (Prettau® 4 Anterior®, Zirkonzahn) were produced to a shallow chamfer molar preparation. The 3Y-crowns were divided into four groups and attached to composite abutment duplicates (SDR® flow+, Dentsply DeTrey GmbH) using the following four cementation techniques; (1) Self-adhesive resin-based cement, (2) Pre-treatment with air-abrasion and self-adhesive resin-based cement, (3) Zinc phosphate cement, (4) Glass-ionomer cement. The 5Y-crowns were divided into two groups and attached to the duplicates with; (1) Self-adhesive resin-based cement, or (2) Air-abrasion pre-treatment and self-adhesive resin-based cement. All crowns were loaded axially (0.5 mm/min) on the occlusal surface until fracture occurred. Results Among the 3Y-zirconia groups, the zinc phosphate cement group fractured at lower loads compared to the resin-based cement groups, with and without air-abrasion, (p < .012). Among the 5Y-groups the air-abraded crowns fractured at statistically significant lower loads compared to the untreated crowns (p < .028). Load at fracture values were significantly different between the two zirconia materials (p < .001), with fracture loads ranging from 3873 to 7500 N in the 3Y-groups, and 2100 to 4948 N in the 5Y-groups. Conclusions Resin-based cementation increased the fracture load compared to non-adhesive cementation. The 3Y-crowns fractured at almost twice the loads of the 5Y-crowns. Pre-treatment with air abrasion reduced the strength of the 5Y-crowns only, showing the importance of differentiating the treatment of the two materials.
Collapse
Affiliation(s)
- Janne Angen Indergård
- Faculty of Medicine, Department of Clinical Dentistry, University of Bergen, Bergen, Norway
| | - Anneli Skjold
- Faculty of Medicine, Department of Clinical Dentistry, University of Bergen, Bergen, Norway
| | - Christian Schriwer
- Faculty of Medicine, Department of Clinical Dentistry, University of Bergen, Bergen, Norway
| | - Marit Øilo
- Faculty of Medicine, Department of Clinical Dentistry, University of Bergen, Bergen, Norway
| |
Collapse
|
17
|
Effect of Different Surface Treatments of Lithium Disilicate on the Adhesive Properties of Resin Cements. MATERIALS 2021; 14:ma14123302. [PMID: 34203752 PMCID: PMC8232589 DOI: 10.3390/ma14123302] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 06/08/2021] [Accepted: 06/11/2021] [Indexed: 01/30/2023]
Abstract
The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF −90 s group (17.71 MPa), while the lowest values were observed in the 5% HF −20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as β (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.
Collapse
|
18
|
Papadopoulos I, Fuller J. Restoration of localised erosive wear using a combination of dental materials: a conservative approach. Br Dent J 2021; 230:294-300. [PMID: 33712779 DOI: 10.1038/s41415-021-2697-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Accepted: 08/17/2020] [Indexed: 11/09/2022]
Abstract
Objectives To present the treatment approach for the restoration of localised anterior erosive wear using a combination of dental materials.Clinical considerations A patient presented in a private dental practice concerned about the aesthetics of his anterior teeth. The patient's history and clinical examination revealed erosive wear on the labial and palatal aspects of his maxillary central incisors and right lateral incisor. The formulated treatment plan was to restore the teeth in a conservative way. A diagnostic wax-up was performed and confirmed with the patient with chairside mock-up. The treatment provided included direct composite restorations, replacement of a porcelain-fused-to-metal crown on his left lateral incisor with a porcelain-fused-to-zirconia crown, and lithium disilicate ceramic veneers on the worn labial surfaces of the central incisors and the right lateral incisor. The preparations for the ceramic veneers were carried out with the aid of the diagnostic mock-up, thus minimising the need for tooth removal of the worn teeth.Conclusions Pre-operative planning for tooth surface loss cases can help to ensure that little or no remaining tooth structure is removed during the restorative procedures. A strict bonding protocol is crucial to ensure longevity of the restorations.
Collapse
Affiliation(s)
- Ioannis Papadopoulos
- Clinical Lecturer in Prosthodontics, Barts and The London Institute of Dentistry, Queen Mary University of London, London, UK; Specialist Prosthodontist, Dental Beauty Dulwich, London, UK.
| | - Jennifer Fuller
- Specialist Registrar in Restorative Dentistry, Barts NHS Trust, Royal London Dental Hospital, London, UK
| |
Collapse
|
19
|
Clinical performance of CAD-CAM crowns provided by predoctoral students at the University of Toronto. J Prosthet Dent 2021; 127:729-736. [PMID: 33423821 DOI: 10.1016/j.prosdent.2020.09.048] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 09/23/2020] [Accepted: 09/23/2020] [Indexed: 11/21/2022]
Abstract
STATEMENT OF PROBLEM The clinical success of monolithic lithium disilicate glass-ceramic (LDGC) crowns manufactured with computer-aided design and computer-aided manufacturing (CAD-CAM) technology provided by predoctoral students has not been fully investigated. PURPOSE The purpose of this retrospective clinical study was to evaluate the performance of laboratory-fabricated monolithic posterior LDGC CAD-CAM crowns provided by predoctoral students at the University of Toronto. Specific patient- and provider-related factors were also investigated. MATERIAL AND METHODS A sample of posterior LDGC CAD-CAM crowns (IPS e.max) provided by predoctoral students was evaluated. Crown preparations were made according to specific criteria, and crowns were milled in an in-house laboratory by using the CEREC Bluecam system. The crowns were cemented with Rely-X Unicem (3M ESPE) and Calibra Universal (Dentsply Sirona) resin cements. Clinical assessments of the crowns and supporting periodontal structures were performed following the modified California Dental Association (CDA) criteria. Intraoral photographs and periapical and bitewing radiographs were obtained for further assessment by 2 evaluators. Descriptive statistics, McNemar, t test, log rank (Mantel-Cox) tests, Pearson chi-squared tests, simple logistic regression, odds ratios, and Kaplan Meier survival analyses were performed (α=.05). RESULTS A total of 189 patients receiving 210 crowns (108 premolar and 102 molar) were examined with a follow-up period of up to 6 years. Altogether, 28 complications were observed (12 technical, 11 biological, and 5 esthetic). No significant association was found between patient age, sex, periodontal condition, tooth type, tooth vitality, cement type, and crown longevity. However, significantly lower survival and success rates were found for mandibular crowns than for maxillary crowns (P=.029). The provider's experience had no significant effect on the clinical performance of LDGC CAD-CAM crowns. The 6-year cumulative survival rate was 93.0%, and the success rate was 86.4%. CONCLUSIONS The ease of use of the CAD-CAM system and clinical performance of LDGC suggest that this technology should be used in the dental school setting by predoctoral students.
Collapse
|
20
|
Influence of Low-Pressure Plasma on the Surface Properties of CAD-CAM Leucite-Reinforced Feldspar and Resin Matrix Ceramics. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10248856] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The introduction of new ceramic materials for dental restorations is currently a reality; however, little information is available on their surface treatment for the bonding process. Furthermore, surface treatment with plasma on ceramic materials has been recently introduced, although not many studies are available. The aim of this study was to evaluate the surface properties of a leucite-reinforced feldspar ceramic (LIC) and resin matrix ceramic (RMC) after low-pressure plasma treatment. From each material, 48 discs were prepared and subject to surface treatment. The LIC group was treated by hydrofluoric acid (HF) (LIC-HF), plasma with oxygen (LIC-O2), and plasma with argon (LIC-Ar). The RMC group was treated by sandblasting with alumina (RMC-SB), plasma with oxygen (RMC-O2), and plasma with argon (RMC-Ar). The groups whose surfaces were not subjected to treatment were considered as the control group. Surface wettability and roughness was analyzed. The results showed significant differences among the treatments for both ceramics regarding wettability and roughness. Plasma treatments increased the wettability and had a very low effect on the roughness. Plasma treatments achieved similar values for both surface properties in each ceramic group with no differences between both treatments. Plasma treatment seems to be a promising alternative for ceramic surface treatments since it increased the surface energy of the ceramics analyzed and hardly affects the roughness. Further studies are necessary to evaluate the effect of plasma treatment on the bond strength of ceramics.
Collapse
|
21
|
Babiuc I, Păuna MR. Surgical extrusion to provide a ferrule for restoring a tooth with a compromised prognosis: A clinical report. J Prosthet Dent 2020; 126:616-621. [PMID: 33172649 DOI: 10.1016/j.prosdent.2020.06.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 06/16/2020] [Accepted: 06/16/2020] [Indexed: 11/26/2022]
Abstract
A surgical extrusion technique was used to provide a ferrule for a tooth with significant tooth structure loss and an oblique coronal fracture. The maxillary lateral incisor was surgically repositioned coronally to provide sufficient dentinal wall for a good prognosis of the restorative treatment. The procedure is conservative and relatively straightforward and can be performed rapidly with minimal patient discomfort.
Collapse
Affiliation(s)
- Iuliana Babiuc
- Assistant Professor, Department of Removable Prosthodontics, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania.
| | - Mihaela-Rodica Păuna
- Professor, Department of Removable Prosthodontics, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, Bucharest, Romania
| |
Collapse
|
22
|
Moriya Y, Komine F, Honda J, Kusaba K, Kitani J, Matsumura H. Effect of luting agent type on fracture loads of implant-supported ceramic premolar prostheses. Dent Mater J 2020; 39:869-876. [PMID: 32448848 DOI: 10.4012/dmj.2019-216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
To investigate the effect of luting agent type on fracture loads of implant-supported ceramic prostheses in premolar region. Ninety-nine implant-abutment complexes were divided into three different implant-supported prostheses: monolithic yttria-partially stabilized zirconia (Y-PSZ) restorations (MPZ specimens), porcelain layered on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations (PLZ specimens), and monolithic lithium disilicate ceramic restorations (MLD specimens). Implant-supported prostheses were luted with adhesive resin luting agent (RLA), glass ionomer cement (GIC), or zinc phosphate cement (ZPC). For MPZ and MLD specimens, fracture loads were significantly higher for RLA group than for GIC and ZPC groups. For PLZ specimens, fracture loads did not significantly differ in relation to luting agent. Fracture loads were significantly higher for MPZ specimens than for other test specimens, regardless of luting agent. Use of an adhesive resin luting agent is recommended for placement of premolar implant-supported monolithic Y-PSZ and lithium disilicate ceramic prostheses.
Collapse
Affiliation(s)
- Yuta Moriya
- Major in Fixed Prosthodontics, Nihon University Graduate School of Dentistry
| | - Futoshi Komine
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Junichi Honda
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Kosuke Kusaba
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| | - Jin Kitani
- Major in Fixed Prosthodontics, Nihon University Graduate School of Dentistry
| | - Hideo Matsumura
- Department of Fixed Prosthodontics, Nihon University School of Dentistry
| |
Collapse
|
23
|
Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2020; 124:274-349. [PMID: 32811666 DOI: 10.1016/j.prosdent.2020.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 06/23/2020] [Accepted: 06/24/2020] [Indexed: 01/20/2023]
Abstract
This comprehensive review of the 2019 restorative dental literature is offered to inform busy dentists regarding remarkable publications and noteworthy progress made in the profession. Developed by the Scientific Investigation Committee of the American Academy of Restorative Dentistry, each author brings discipline-specific expertise to 1 of 8 sections of the report: (1) prosthodontics; (2) periodontics, alveolar bone, and peri-implant tissues; (3) implant dentistry; (4) dental materials and therapeutics; (5) occlusion and temporomandibular disorders; (6) sleep-related breathing disorders; (7) oral medicine and oral and maxillofacial surgery; and (8) dental caries and cariology. The report targets important information likely to influence day-to-day dental treatment decisions. Each review is not intended to stand alone but to update interested readers so that they may visit source material when greater detail is desired. As the profession moves toward evidence-based clinical decision-making, an incredible volume of potentially valuable dental literature continues to increase. It is the intention of this review and its authors to provide assistance in negotiating the extensive dental literature published in 2019. It is our hope that readers find this work useful in the clinical management of dental patients.
Collapse
|
24
|
Woo ES, Goldstein G, Choi M, Bromage TG. In vitro shear bond strength of 2 resin cements to zirconia and lithium disilicate: An in vitro study. J Prosthet Dent 2020; 125:529-534. [PMID: 32354421 DOI: 10.1016/j.prosdent.2020.02.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 02/10/2020] [Accepted: 02/11/2020] [Indexed: 10/24/2022]
Abstract
STATEMENT OF PROBLEM There is little evidence on how the multiple layers of zirconia (ZrO2) or glazed material will affect the shear bond strength (SBS) of different resin cements. PURPOSE The purpose of this in vitro study was to compare the SBS of 2 resin cements with the different layers of a monolithic polychromatic ZrO2 ceramic, both glazed and nonglazed, and a lithium disilicate (LDS) ceramic. MATERIAL AND METHODS One hundred and sixty-eight composite resin cylinders and 48 monolithic polychromic ZrO2 plates were prepared. Twenty-four were milled and sintered, and 24 were milled and sintered and had a glaze cycle applied with no liquid glaze. These plates and 12 LDS plates were mounted in autopolymerized acrylic resin. Bonding surfaces were polished, airborne-particle abraded, and cleaned ultrasonically. The different layers (cubic, hybrid, and tetragonal) of the ZrO2 plates were identified and marked. The plates were assigned to 2 cement groups: a self-adhesive, autopolymerized resin cement, and a dual-polymerizing, adhesive resin cement (DPRC). Bonding surfaces were cleaned and treated according to the cement manufacturer's instructions. Three composite resin cylinders were luted to the ZrO2 plates at the appropriate layer, and 2 cylinders were luted to each LDS plate. The specimens were stored in a moist environment for 24 hours at 37 °C. The SBS test was performed with a universal testing machine. Visual inspections of the debonded surfaces were compared under magnification. The data were analyzed with a 2-way ANOVA and a subsequent Student t test (α=.05). RESULTS The 2-way ANOVA found no difference among luting agent and LDS and ZrO2. The SBSs of the nonglazed tetragonal and cubic layer to the ZrO2 were higher than to the surface exposed to a glazing cycle (P=.001). The bonded surfaces were examined tactilely and under ×3.5 magnification, followed by light and scanning electron microscopy and recorded as either adhesive, cohesive, or mixed. Almost all failures in the glazed ZrO2 were mixed and cohesive. However, more adhesive failures were observed in the DPRC group of nonglazed ZrO2. CONCLUSIONS No differences were found between the 2 luting agents for the LDS. For the ZrO2 cubic and tetragonal layers, the DPRC had higher bond strengths to the nonglazed surfaces.
Collapse
Affiliation(s)
- Evelyn Seungmin Woo
- Adjunct Clinical Assistant Professor, Department of Prosthodontics, New York University College of Dentistry, New York, N.Y
| | | | - Mijin Choi
- Clinical Associate Professor, Director Advanced Education Program in Prosthodontics, Department of Prosthodontics, New York University College of Dentistry, New York, N.Y
| | - Timothy G Bromage
- Professor, Department of Biomaterials and Department of Basic Science and Craniofacial Biology, New York University College of Dentistry, New York, N.Y
| |
Collapse
|
25
|
Effect of Incisal Porcelain Veneering Thickness on the Fracture Resistance of CAD/CAM Zirconia All-Ceramic Anterior Crowns. Int J Dent 2019; 2019:6548519. [PMID: 31534456 PMCID: PMC6732585 DOI: 10.1155/2019/6548519] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 05/21/2019] [Indexed: 11/17/2022] Open
Abstract
Statement of Problem. In some clinical situations, the vertical length of either a prepared tooth or an implant abutment is short, while the occlusal clearance to be restored by a porcelain crown is large. Incisal thickness of the veneering porcelain should be considered to prevent mechanical failure of the crown. Purpose. The aim of this study is to evaluate the effect of two different incisal veneering porcelain thickness on the fracture resistance of the anterior all-ceramic CAD/CAM zirconia crown system as compared with the conventionally used metal ceramic crown system. Method. CAD/CAM zirconia all-ceramic and metal ceramic crowns were fabricated on the prepared dies with standardized dimensions and designs using standardized methods according to the manufacturer’s instructions. All crowns were then adhesively luted with resin-based cement (Multilink cement system), subjected to thermal cycling and cyclic loading, and were loaded until fracture using the universal testing machine to indicate the fracture resistance for each crown material in each veneering thickness. Results. Statistical analysis was carried out, and the results showed that the fracture resistance of the nickel-chromium metal ceramic group was significantly higher than that of the CAD/CAM zirconia all-ceramic group. Also, the fracture resistance of crowns with 1.5 mm incisal veneering thickness was significantly higher than those with 3 mm incisal veneering thickness in both groups. Furthermore, there was no significant difference in the fracture mode of the two groups where 50% of the total specimens demonstrated Mode II (veneer chipping), while 35% demonstrated Mode I (visible crack) and only 15% demonstrated Mode III (bulk fracture). Conclusion. High failure load values were demonstrated by the specimens in this study, which suggest sufficient strength of both incisal veneering thickness in both crown systems to withstand clinical applications; however, the fracture patterns still underline the requirement of a core design that support a consistent thickness of the veneering ceramic, and it is recommended to conduct long-term prospective clinical studies to confirm findings reported in the present study.
Collapse
|