Jiang Y, Long H, Soo SY, Mavani H, Tew IM. Accuracy of Complete-Arch Scans Obtained by Intraoral Scanner and Smartphone Three-Dimensional Scanning Applications With Different Smartphone Position Setups: An In Vitro Study. Cureus 2024; 16:e63471. [PMID: 39077296 PMCID: PMC11286105 DOI: 10.7759/cureus.63471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/29/2024] [Indexed: 07/31/2024] Open
Abstract
INTRODUCTION The high cost of intraoral scanners (IOS) for complete-arch scans makes them less accessible for many dental practitioners. As a viable alternative, smartphone scanner applications (SMP) provide comparable scanning capabilities at a significantly low cost. However, there is limited data on the accuracy of SMP, especially when used in various smartphone positions. This study aimed to compare the three-dimensional (3D) and linear accuracy of complete-arch scans acquired by an IOS and SMP (KIRI Engine, KIRI Innovations, Guangdong, China) at three shooting angles (0°, 45°, and 90° for SMP_3A) and two shooting angles (30° and 60° for SMP_2A). METHODS A stone dental cast was scanned with a laboratory scanner as a reference, with 11 scans performed by an IOS, SMP_2A, and SMP_3A. In 3D analysis, trueness and precision were evaluated through superimposition with the reference scan and within each group, respectively, using the best-fit algorithm of Geomagic Wrap software (3D Systems, Inc., Rock Hill, SC). Trueness in linear discrepancy was assessed by comparing the occlusal-cervical and mesiodistal dimensions of reference teeth (canine, premolar, and molar), intercanine width, and intermolar width on the digital casts to measurements of the stone cast, while precision was measured using the coefficient of variance. Differences between groups were analyzed using the Friedman test, followed by the Dunn-Bonferroni post hoc test with a significance level set at 0.05. RESULTS IOS exhibited significantly lower trueness than SMP_2A (p = 0.003) with significantly greater width discrepancies on canines (p = 0.001) and molars (p < 0.001). Discrepancy patterns differed among the three scanning methods. The IOS showed greater discrepancies on the occlusal surfaces of posterior teeth. While SMP_3A demonstrated higher variation on the palatal surfaces and interproximal areas of posterior teeth. For precision, SMP_3A (p = 0.028) and SMP_2A (p = 0.003) showed a significantly lower precision in 3D analysis, but a comparable reproducibility in linear measurement to IOS. CONCLUSION TRIOS IOS (3Shape, Copenhagen, Denmark) exhibited lower trueness in 3D and linear accuracy analyses for complete-arch scans. The positions of the smartphone significantly enhanced trueness at the undercut region. SMP_2A and SMP_3A can be a potential alternative for precise linear measurement in complete-arch scans with selective use.
Collapse
Affiliation(s)
- Yuhao Jiang
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| | - Hu Long
- Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, CHN
| | - Suet Yeo Soo
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| | - Hetal Mavani
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| | - In Meei Tew
- Department of Restorative Dentistry, The National University of Malaysia, Kuala Lumpur, MYS
| |
Collapse
|
2
|
Generalova AN, Vikhrov AA, Prostyakova AI, Apresyan SV, Stepanov AG, Myasoedov MS, Oleinikov VA. Polymers in 3D printing of external maxillofacial prostheses and in their retention systems. Int J Pharm 2024; 657:124181. [PMID: 38697583 DOI: 10.1016/j.ijpharm.2024.124181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 04/12/2024] [Accepted: 04/28/2024] [Indexed: 05/05/2024]
Abstract
Maxillofacial defects, arising from trauma, oncological disease or congenital abnormalities, detrimentally affect daily life. Prosthetic repair offers the aesthetic and functional reconstruction with the help of materials mimicking natural tissues. 3D polymer printing enables the design of patient-specific prostheses with high structural complexity, as well as rapid and low-cost fabrication on-demand. However, 3D printing for prosthetics is still in the early stage of development and faces various challenges for widespread use. This is because the most suitable polymers for maxillofacial restoration are soft materials that do not have the required printability, mechanical strength of the printed parts, as well as functionality. This review focuses on the challenges and opportunities of 3D printing techniques for production of polymer maxillofacial prostheses using computer-aided design and modeling software. Review discusses the widely used polymers, as well as their blends and composites, which meet the most important assessment criteria, such as the physicochemical, biological, aesthetic properties and processability in 3D printing. In addition, strategies for improving the polymer properties, such as their printability, mechanical strength, and their ability to print multimaterial and architectural structures are highlighted. The current state of the prosthetic retention system is presented with a focus on actively used polymer adhesives and the recently implemented prosthesis-supporting osseointegrated implants, with an emphasis on their creation from 3D-printed polymers. The successful prosthetics is discussed in terms of the specificity of polymer materials at the restoration site. The approaches and technological prospects are also explored through the examples of the nasal, auricle and ocular prostheses, ranging from prototypes to end-use products.
Collapse
Affiliation(s)
- Alla N Generalova
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia; Federal Scientific Research Center "Crystallography and Photonics" of the Russian Academy of Sciences, 119333 Moscow, Russia.
| | - Alexander A Vikhrov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Anna I Prostyakova
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Samvel V Apresyan
- Institute of Digital Dentistry, Medical Institute, Peoples' Friendship University of Russia (RUDN University), Miklukho-Maklaya 6, 117198 Moscow, Russia
| | - Alexander G Stepanov
- Institute of Digital Dentistry, Medical Institute, Peoples' Friendship University of Russia (RUDN University), Miklukho-Maklaya 6, 117198 Moscow, Russia
| | - Maxim S Myasoedov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| | - Vladimir A Oleinikov
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry of the Russian Academy of Sciences, Miklukho-Maklaya 16/10, 117997 Moscow, Russia
| |
Collapse
|
3
|
Farook TH, Ahmed S, Giri J, Rashid F, Hughes T, Dudley J. Influence of Intraoral Scanners, Operators, and Data Processing on Dimensional Accuracy of Dental Casts for Unsupervised Clinical Machine Learning: An In Vitro Comparative Study. Int J Dent 2023; 2023:7542813. [PMID: 38033456 PMCID: PMC10686707 DOI: 10.1155/2023/7542813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 10/28/2023] [Accepted: 10/31/2023] [Indexed: 12/02/2023] Open
Abstract
Purpose This study assessed the impact of intraoral scanner type, operator, and data augmentation on the dimensional accuracy of in vitro dental cast digital scans. It also evaluated the validation accuracy of an unsupervised machine-learning model trained with these scans. Methods Twenty-two dental casts were scanned using two handheld intraoral scanners and one laboratory scanner, resulting in 110 3D cast scans across five independent groups. The scans underwent uniform augmentation and were validated using Hausdorff's distance (HD) and root mean squared error (RMSE), with the laboratory scanner as reference. A 3-factor analysis of variance examined interactions between scanners, operators, and augmentation methods. Scans were divided into training and validation sets and processed through a pretrained 3D visual transformer, and validation accuracy was assessed for each of the five groups. Results No significant differences in HD and RMSE were found across handheld scanners and operators. However, significant changes in RMSE were observed between native and augmented scans with no specific interaction between scanner or operator. The 3D visual transformer achieved 96.2% validation accuracy for differentiating upper and lower scans in the augmented dataset. Native scans lacked volumetric depth, preventing their use for deep learning. Conclusion Scanner, operator, and processing method did not significantly affect the dimensional accuracy of 3D scans for unsupervised deep learning. However, data augmentation was crucial for processing intraoral scans in deep learning algorithms, introducing structural differences in the 3D scans. Clinical Significance. The specific type of intraoral scanner or the operator has no substantial influence on the quality of the generated 3D scans, but controlled data augmentation of the native scans is necessary to obtain reliable results with unsupervised deep learning.
Collapse
Affiliation(s)
| | - Saif Ahmed
- Department of Electrical and Computer Engineering, North South University, Dhaka, Bangladesh
| | - Jamal Giri
- Adelaide Dental School, The University of Adelaide, Adelaide, Australia
| | - Farah Rashid
- Adelaide Dental School, The University of Adelaide, Adelaide, Australia
| | - Toby Hughes
- Adelaide Dental School, The University of Adelaide, Adelaide, Australia
| | - James Dudley
- Adelaide Dental School, The University of Adelaide, Adelaide, Australia
| |
Collapse
|
4
|
Dudley J, Pellew J, Jamayet NB. Prosthetic management of an ocular defect utilizing a novel threaded iris fabrication technique. Clin Case Rep 2023; 11:e7287. [PMID: 37273667 PMCID: PMC10235795 DOI: 10.1002/ccr3.7287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 01/11/2023] [Accepted: 04/19/2023] [Indexed: 06/06/2023] Open
Abstract
The conservative prosthodontic construction of an ocular prosthesis utilizing our novel threaded iris fabrication technique required high time and prosthodontic resource inputs and produced a lifelike aesthetic result. Abstract Patients with ocular defects frequently present with significant local anatomical deficiencies and complex histories and require extensive time and resource inputs to treat. This case report describes the conservative management of an ocular defect completed in a postgraduate prosthodontics clinical residency program utilizing a novel threaded iris fabrication technique.
Collapse
Affiliation(s)
- James Dudley
- Adelaide Dental SchoolThe University of AdelaideSouth AustraliaAdelaideAustralia
| | - Jane Pellew
- Adelaide Dental SchoolThe University of AdelaideSouth AustraliaAdelaideAustralia
| | - Nafij Bin Jamayet
- School of DentistryInternational Medical UniversityKuala LumpurMalaysia
| |
Collapse
|
5
|
Tareq A, Faisal MI, Islam MS, Rafa NS, Chowdhury T, Ahmed S, Farook TH, Mohammed N, Dudley J. Visual Diagnostics of Dental Caries through Deep Learning of Non-Standardised Photographs Using a Hybrid YOLO Ensemble and Transfer Learning Model. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:5351. [PMID: 37047966 PMCID: PMC10094335 DOI: 10.3390/ijerph20075351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/16/2023] [Accepted: 03/29/2023] [Indexed: 06/19/2023]
Abstract
BACKGROUND Access to oral healthcare is not uniform globally, particularly in rural areas with limited resources, which limits the potential of automated diagnostics and advanced tele-dentistry applications. The use of digital caries detection and progression monitoring through photographic communication, is influenced by multiple variables that are difficult to standardize in such settings. The objective of this study was to develop a novel and cost-effective virtual computer vision AI system to predict dental cavitations from non-standardised photographs with reasonable clinical accuracy. METHODS A set of 1703 augmented images was obtained from 233 de-identified teeth specimens. Images were acquired using a consumer smartphone, without any standardised apparatus applied. The study utilised state-of-the-art ensemble modeling, test-time augmentation, and transfer learning processes. The "you only look once" algorithm (YOLO) derivatives, v5s, v5m, v5l, and v5x, were independently evaluated, and an ensemble of the best results was augmented, and transfer learned with ResNet50, ResNet101, VGG16, AlexNet, and DenseNet. The outcomes were evaluated using precision, recall, and mean average precision (mAP). RESULTS The YOLO model ensemble achieved a mean average precision (mAP) of 0.732, an accuracy of 0.789, and a recall of 0.701. When transferred to VGG16, the final model demonstrated a diagnostic accuracy of 86.96%, precision of 0.89, and recall of 0.88. This surpassed all other base methods of object detection from free-hand non-standardised smartphone photographs. CONCLUSION A virtual computer vision AI system, blending a model ensemble, test-time augmentation, and transferred deep learning processes, was developed to predict dental cavitations from non-standardised photographs with reasonable clinical accuracy. This model can improve access to oral healthcare in rural areas with limited resources, and has the potential to aid in automated diagnostics and advanced tele-dentistry applications.
Collapse
Affiliation(s)
- Abu Tareq
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - Mohammad Imtiaz Faisal
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - Md. Shahidul Islam
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - Nafisa Shamim Rafa
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - Tashin Chowdhury
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - Saif Ahmed
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - Taseef Hasan Farook
- Adelaide Dental School, The University of Adelaide, Adelaide, SA 5005, Australia
| | - Nabeel Mohammed
- Department of Electrical and Computer Engineering, North South University, Dhaka 1229, Bangladesh (S.A.)
| | - James Dudley
- Adelaide Dental School, The University of Adelaide, Adelaide, SA 5005, Australia
| |
Collapse
|
6
|
Farook TH, Rashid F, Alam MK, Dudley J. Variables influencing the device-dependent approaches in digitally analysing jaw movement-a systematic review. Clin Oral Investig 2023; 27:489-504. [PMID: 36577849 DOI: 10.1007/s00784-022-04835-w] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Accepted: 12/19/2022] [Indexed: 12/29/2022]
Abstract
BACKGROUND To explore the digitisation of jaw movement trajectories through devices and discuss the physiological factors and device-dependent variables with their subsequent effects on the jaw movement analyses. METHODS Based on predefined eligibility criteria, the search was conducted following PRISMA-P 2015 guidelines on MEDLINE, EBSCO Host, Scopus, PubMed, and Web of Science databases in 2022 by 2 reviewers. Articles then underwent Cochrane GRADE approach and JBI critical appraisal for certainty of evidence and bias evaluation. RESULTS Thirty articles were included following eligibility screening. Both in vitro experiments (20%) and in vivo (80%) devices ranging from electronic axiography, electromyography, optoelectronic and ultrasonic, oral or extra-oral tracking, photogrammetry, sirognathography, digital pressure sensors, electrognathography, and computerised medical-image tracing were documented. 53.53% of the studies were rated below "moderate" certainty of evidence. Critical appraisal showed 80% case-control investigations failed to address confounding variables while 90% of the included non-randomised experimental studies failed to establish control reference. CONCLUSION Mandibular and condylar growth, kinematic dysfunction of the neuromuscular system, shortened dental arches, previous orthodontic treatment, variations in habitual head posture, temporomandibular joint disorders, fricative phonetics, and to a limited extent parafunctional habits and unbalanced occlusal contact were identified confounding variables that shaped jaw movement trajectories but were not highly dependent on age, gender, or diet. Realistic variations in device accuracy were found between 50 and 330 µm across the digital systems with very low interrater reliability for motion tracing from photographs. Forensic and in vitro simulation devices could not accurately recreate variations in jaw motion and muscle contractions.
Collapse
Affiliation(s)
- Taseef Hasan Farook
- Adelaide Dental School, The University of Adelaide, Adelaide, South Australia, 5005, Australia.
| | - Farah Rashid
- School of Dental Sciences, Universiti Sains Malaysia, Kota Bharu, 16150, Malaysia
| | | | - James Dudley
- Adelaide Dental School, The University of Adelaide, Adelaide, South Australia, 5005, Australia
| |
Collapse
|
7
|
Unkovskiy A, Spintzyk S, Beuer F, Huettig F, Röhler A, Kraemer-Fernandez P. Accuracy of capturing nasal, orbital, and auricular defects with extra- and intraoral optical scanners and smartphone: An in vitro study. J Dent 2021; 117:103916. [PMID: 34875273 DOI: 10.1016/j.jdent.2021.103916] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 11/29/2021] [Accepted: 12/02/2021] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVES This in vitro study compares the scanning accuracy of various stationary and portable as well as extra- and intraoral devices for capturing oncological defects. METHODS A 3D-printed model of a nasal, orbital, and auricular defect, as well as one of an intact auricle, were digitalized (n = 7 per device) with a stationary optical scanner (Pritiface), a portable extraoral optical scanner (Artec Space Spider), two intraoral scanners (Trios 4 and Primescan), and a smartphone (iPhone 11 Pro). For the reference data, the defect models were digitalized using a laboratory scanner (D2000). For quantitative analysis, the root mean square error value for trueness and precision and mean deviations in millimeters were obtained for each defect type. The data were statistically analyzed using two-way ANOVA and Tukey multiple comparison test. For qualitative analysis, a colorimetric map was generated to display the deviation within the defect area and adjacent tissue. RESULTS Statistically significant interactions were found in the trueness and precision for defect and scanner type. CONCLUSION The Primescan and Artec Space Spider scanners showed the highest accuracy for most defect types. Primescan and Trios 4 failed to capture the orbital defect. The iPhone 11 Pro showed clinically acceptable trueness but inferior precision. CLINICAL SIGNIFICANCE The scanning devices may demonstrate varying accuracy, depending on the defect type. A portable extraoral optical scanner is an universal tool for the digitization of oncological defects. Alternatively, an intraoral scanner may be employed in maxillofacial prosthetics with some restrictions. Utilizing a smartphone in maxillofacial rehabilitation should be considered with caution, because it provides inconsistent accuracy.
Collapse
Affiliation(s)
- Alexey Unkovskiy
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Dental Materials and Biomaterial Research, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; Department of Dental Surgery, Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street, 19с1, 119146 Moscow, Russian Federation.
| | - Sebastian Spintzyk
- Section Medical Materials Science and Technology, Tübingen University Hospital, Osianderstr. 2-8, 72076 Tuebingen, Germany; ADMiRE Lab-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, 9524 Villach
| | - Florian Beuer
- Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Dental Materials and Biomaterial Research, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
| | - Fabian Huettig
- Department of Prosthodontics at the Centre of Dentistry, Oral Medicine and Maxillofacial Surgery with Dental School, Tuebingen University Hospital, Osianderstr. 2-8, Tbingen 72076, Germany
| | - Ariadne Röhler
- Section Medical Materials Science and Technology, Tübingen University Hospital, Osianderstr. 2-8, 72076 Tuebingen, Germany
| | - Pablo Kraemer-Fernandez
- Department of Prosthodontics at the Centre of Dentistry, Oral Medicine and Maxillofacial Surgery with Dental School, Tuebingen University Hospital, Osianderstr. 2-8, Tbingen 72076, Germany
| |
Collapse
|
8
|
Jamayet NB, Farook TH, Al-Oulabi A, Johari Y, Patil PG. Digital workflow and virtual validation of a 3D-printed definitive hollow obturator for a large palatal defect. J Prosthet Dent 2021; 129:798-804. [PMID: 34635339 DOI: 10.1016/j.prosdent.2021.08.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Revised: 07/31/2021] [Accepted: 08/02/2021] [Indexed: 11/19/2022]
Abstract
This clinical report describes how a hollow obturator prosthesis was designed and fabricated for an 82-year-old partially edentulous patient with a large palatal defect. Computer-aided design (CAD) was used to design, articulate, and align the mandibular denture with the obturator prosthesis. The prosthesis was printed, adjusted chairside, rescanned, and made hollow by using a CAD software program. The prosthesis was printed in resin with a dental 3D printer. Quantitative evaluations of clinical (prosthesis dimensions, rest, and occlusal vertical dimensions) and virtual (surface area, volume, weight, interpoint mismatches, spatial overlap) parameters found that the 3D-printed prosthesis required an additional 5% chairside modification. The greatest differences in volume (24.7% less) and weight (22.2% less) were observed when the modified obturator bulb was made hollow via CAD. Hollowing the bulb, therefore, reduced the spatial overlap in volume by 16.8%.
Collapse
Affiliation(s)
- Nafij Bin Jamayet
- Senior Lecturer in Prosthodontics, Division of Restorative Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia.
| | - Taseef Hasan Farook
- Research Fellow, Maxillofacial Prosthetic Service, Prosthodontic Unit, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
| | - Ayman Al-Oulabi
- Clinical Fellow, Prosthodontic Unit, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
| | - Yanti Johari
- Senior Lecturer in Prosthodontics, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kota Bharu, Kelantan, Malaysia
| | - Pravinkumar G Patil
- Senior Lecturer in Prosthodontics, Division of Restorative Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia
| |
Collapse
|
9
|
Kois JC, Kois DE, Zeitler JM, Martin J. Digital to Analog Facially Generated Interchangeable Facebow Transfer: Capturing a Standardized Reference Position. J Prosthodont 2021; 31:13-22. [PMID: 34605582 DOI: 10.1111/jopr.13437] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/24/2021] [Indexed: 12/01/2022] Open
Abstract
Although the evolution of digital technology continues to improve patient data acquisition, the ability to both standardize the recording of the maxillary occlusal plane and capture the necessary dynamic data for dento-facial analysis remains elusive. This article describes step-by-step techniques to position the maxilla on an articulator using the natural head position and a facial reference system (Kois Facial Reference Glasses) for both analog and digital workflows. A photographic technique will be presented that captures the natural head position and allows the clinician to align a 2D reference photograph with the maxillary intraoral digital scan and the virtual articulator. Using this reference photograph, the clinician can record and communicate to the technician the maxillary arch position in relationship with the facial references, as well as transfer the additively manufactured casts in the same facial orientation for mounting and analysis either virtually or on an analog articulator. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- John C Kois
- Founder and Director Kois Center, Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry University of Washington, Private Practice, Seattle, Washington
| | - Dean E Kois
- Private practice, Faculty Kois Center, Seattle, Washington
| | | | | |
Collapse
|
10
|
Gibelli D, Palamenghi A, Poppa P, Sforza C, Cattaneo C, De Angelis D. Improving 3D-3D facial registration methods: potential role of three-dimensional models in personal identification of the living. Int J Legal Med 2021; 135:2501-2507. [PMID: 34241673 PMCID: PMC8523506 DOI: 10.1007/s00414-021-02655-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 06/27/2021] [Indexed: 11/29/2022]
Abstract
Personal identification of the living from video surveillance systems usually involves 2D images. However, the potentiality of three-dimensional facial models in gaining personal identification through 3D-3D comparison still needs to be verified. This study aims at testing the reliability of a protocol for 3D-3D registration of facial models, potentially useful for personal identification. Fifty male subjects aged between 18 and 45 years were randomly chosen from a database of 3D facial models acquired through stereophotogrammetry. For each subject, two acquisitions were available; the 3D models of faces were then registered onto other models belonging to the same and different individuals according to the least point-to-point distance on the entire facial surface, for a total of 50 matches and 50 mismatches. RMS value (root mean square) of point-to-point distance between the two models was then calculated through the VAM® software. Intra- and inter-observer errors were assessed through calculation of relative technical error of measurement (rTEM). Possible statistically significant differences between matches and mismatches were assessed through Mann–Whitney test (p < 0.05). Both for intra- and inter-observer repeatability rTEM was between 2.2 and 5.2%. Average RMS point-to-point distance was 0.50 ± 0.28 mm in matches, 2.62 ± 0.56 mm in mismatches (p < 0.01). An RMS threshold of 1.50 mm could distinguish matches and mismatches in 100% of cases. This study provides an improvement to existing 3D-3D superimposition methods and confirms the great advantages which may derive to personal identification of the living from 3D facial analysis.
Collapse
Affiliation(s)
- Daniele Gibelli
- Dipartimento Di Scienze Biomediche Per La Salute, LAFAS, Laboratorio Di Anatomia Funzionale Dell'Apparato Stomatognatico, Università Degli Studi Di Milano, Via Mangiagalli 31, 20133, Milano, Italy.
| | - Andrea Palamenghi
- Dipartimento Di Scienze Biomediche Per La Salute, LAFAS, Laboratorio Di Anatomia Funzionale Dell'Apparato Stomatognatico, Università Degli Studi Di Milano, Via Mangiagalli 31, 20133, Milano, Italy.,Dipartimento Di Scienze Biomediche Per La Salute, LABANOF, Laboratorio Di Antropologia E Odontologia Forense, Università Degli Studi Di Milano, Via Mangiagalli 37, 20133, Milano, Italy
| | - Pasquale Poppa
- Dipartimento Di Scienze Biomediche Per La Salute, LABANOF, Laboratorio Di Antropologia E Odontologia Forense, Università Degli Studi Di Milano, Via Mangiagalli 37, 20133, Milano, Italy
| | - Chiarella Sforza
- Dipartimento Di Scienze Biomediche Per La Salute, LAFAS, Laboratorio Di Anatomia Funzionale Dell'Apparato Stomatognatico, Università Degli Studi Di Milano, Via Mangiagalli 31, 20133, Milano, Italy
| | - Cristina Cattaneo
- Dipartimento Di Scienze Biomediche Per La Salute, LABANOF, Laboratorio Di Antropologia E Odontologia Forense, Università Degli Studi Di Milano, Via Mangiagalli 37, 20133, Milano, Italy
| | - Danilo De Angelis
- Dipartimento Di Scienze Biomediche Per La Salute, LABANOF, Laboratorio Di Antropologia E Odontologia Forense, Università Degli Studi Di Milano, Via Mangiagalli 37, 20133, Milano, Italy
| |
Collapse
|