1
|
Bezerra A, Gonçalves G, Alves LC, Stamfor T, De Brito O, Monteiro GQ. Bacterial Adhesion and In Situ Biodegradation of Preheated Resin Composite Used as a Luting Agent for Indirect Restorations. Oper Dent 2024; 49:725-737. [PMID: 39420222 DOI: 10.2341/23-132-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/06/2024] [Indexed: 10/19/2024]
Abstract
OBJECTIVE To evaluate surface roughness and bacterial adhesion after in situ biodegradation of the cementation interface of indirect restorations cemented with preheated resin composite. METHODS AND MATERIALS Resin composite blocks (Z250XT/3M ESPE) were cemented to bovine enamel (7 × 2.5 × 2 mm) using preheated microhybrid resin composites: (1) Filtek Z100 (3M ESPE) (Z100); (2) Gradia Direct X (GC America) (GDX); and (3) Light-cured resin cement RelyX Veneer (3M ESPE) (RXV) (n=21). The resin composites were preheated on a heating device (HotSet, Technolife) at 69°C for 30 minutes. Disk-shaped specimens (7 × 1.5 mm) were made for biodegradation analysis with the luting agents (n=25). The in situ phase consisted of 20 volunteers' using an intraoral palatal device for 7 days. Each device had six cylindrical wells for the blocks and the disk-shaped specimens. Biodegradation was evaluated through surface roughness (Ra), scanning electron microscopy (SEM) micromorphological analysis, and colony-forming unit (CFU) count. The film thickness of the luting agents was also measured under stereomicroscopy. RESULTS Increased surface roughness was observed after the cariogenic challenge without differences between the luting agents. Higher variation and surface flaws suggestive of particulate detachment were observed for Z100. No differences were observed in CFU counts. CONCLUSIONS All materials underwent surface biodegradation, and the surface roughness of the resin cements was similar to or lower than that of the preheated resin composites. The resin composites' film thickness was thicker than that of the resin cement. Clinicians should be aware of these factors when choosing the use of preheated resin composite since it can lead to reduced longevity of the cementation interface and, therefore, restorations.
Collapse
Affiliation(s)
- Alca Bezerra
- Ana Luisa Cassiano Alves Bezerra, MSc, Universidade de Pernambuco, Recife, Pernambuco, Brazil
| | - Gga Gonçalves
- Gabriel Gazzoni Araújo Gonçalves, PhD, Keizo Asami Institute/ Universidade Federal de Pernambuco, Recife, Pernambuco, Brazil
| | - L C Alves
- Luiz Carlos Alves, Keizo Asami and Aggeu Magalhães Institute/-Universidade Federal de Pernambuco, Recife, Pernambuco, Brazil
| | - Tcm Stamfor
- TThayza Christina Montenegro Stamford, PhD, Universidade Federal de Pernambuco, Recife, Pernambuco, Brazil
| | - Off De Brito
- Oscar Felipe Fonseca De Brito, PhD, Universidade Federal de Pernambuco, Recife, Pernambuco, Brazil
| | - GQdeM Monteiro
- *Gabriela Queiroz de Melo Monteiro, PhD, Universidade de Pernambuco, Recife, Pernambuco, Brazil
| |
Collapse
|
2
|
Chiodera G, Monterubbianesi R, Tosco V, Papini O, Orsini G, Putignano A. Application of Bulk-Fill Composite to Simplify the Cementation of Indirect Restorations: The COMBO Technique. Dent J (Basel) 2024; 12:239. [PMID: 39195083 DOI: 10.3390/dj12080239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 06/19/2024] [Accepted: 07/05/2024] [Indexed: 08/29/2024] Open
Abstract
This article proposes a technique to simplify the cementation of indirect restorations by exploiting the advantageous properties of bulk-fill composites (BFCs). The proposed technique consists of using a thin layer of a high-viscosity (HV) BFC in the interproximal margins of the preparation and applying low-viscosity (LV) resin luting agents (RLAs) to the rest of the prepared surface. The application of the HV BFC limits the extrusion of the LV RLAs in the interproximal area, deviating the excesses of LV RLAs only on the vestibular and lingual side. This deviation allows the management and control of the excess material in complicated interproximal spaces, simplifying the cementation procedure of indirect restorations and achieving a reliable final result in terms of removing excess in a safe and repeatable way. This technical report provides an alternative clinical approach for cementing indirect restorations using the consistency and viscosity of different RLAs.
Collapse
Affiliation(s)
| | - Riccardo Monterubbianesi
- Department of Clinical Sciences and Stomatology, Università Politecnica delle Marche, 60126 Ancona, Italy
| | - Vincenzo Tosco
- Department of Clinical Sciences and Stomatology, Università Politecnica delle Marche, 60126 Ancona, Italy
| | | | - Giovanna Orsini
- Department of Clinical Sciences and Stomatology, Università Politecnica delle Marche, 60126 Ancona, Italy
| | - Angelo Putignano
- Department of Clinical Sciences and Stomatology, Università Politecnica delle Marche, 60126 Ancona, Italy
- National Institute of Health and Science of Aging (INRCA), 60124 Ancona, Italy
| |
Collapse
|
3
|
Bueno T, Masoud N, Akkus A, Silva I, McPherson K, Furuse AY, Rizzante F. Effects of pre-heating on physical-mechanical-chemical properties of contemporary resin composites. Odontology 2024:10.1007/s10266-024-00953-x. [PMID: 38797796 DOI: 10.1007/s10266-024-00953-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 05/09/2024] [Indexed: 05/29/2024]
Abstract
This research assessed the effects of pre-heating on the physical-mechanical-chemical properties of different resin composites. For this, resin composites were evaluated in 6 levels: Admira/ADM, Vitra/VIT, Filtek Supreme/FS, Filtek Supreme Flowable/FSF, Filtek One/FO, and Filtek Bulk Fill Flowable/FBF; temperature was evaluated in 4 levels using a composite heater: room temperature/22 ºC, 37 ºC, 54 ºC, and 68 ºC. Response variables were: degree of conversion/DC, flexural strength/FS and color stability/ΔE (immediately after light curing/LC, after 7 days of dark-dry-storage, and after 24 h and 3 days of artificial aging in water at 60 ºC). Data were subjected to 2-way ANOVA (DC and FR) and 3-way repeated measurements ANOVA (ΔE), all followed by Tukey's test (α = 5%). DC were similar (FBF, FS, and FSF) or increased (ADM, FO, and VIT) as the temperature increased. Results of FR were unchanged or increased for all composites except VIT and ADM. High-viscosity composites (VIT and FS) showed higher FR values than low-viscosity composite (FSF). For bulk-fill composites, FBF and FO showed similar results, but lower than high-viscosity composites. Results of color stability showed acceptable values up to 3 days aging except for ADM and FSF. ΔE was not influenced by pre-heating and, overall, ΔE: FS < VIT < FO < FSF < ADM < FBF. Only VIT and FS showed ΔE ≤ 3.3 (clinical threshold). Therefore, the effects of pre-heating depend on the material. The tested materials generally showed similar or enhanced properties after pre-heating (except ADM and VIT).
Collapse
Affiliation(s)
| | - Nivien Masoud
- Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, OH, USA
| | - Anna Akkus
- Lubrizol Advanced Materials, Inc, Brecksville, OH, USA
| | - Italo Silva
- Department of Macromolecular Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Karen McPherson
- Department of Reconstructive and Rehabilitation Sciences, James B. Edwards College of Dental Medicine, Department of Oral Rehabilitation, Medical University of South Carolina, 173 Ashley Ave, BSB 550E, Charleston, SC, 29425, USA
| | - Adilson Yoshio Furuse
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - Fabio Rizzante
- Department of Reconstructive and Rehabilitation Sciences, James B. Edwards College of Dental Medicine, Department of Oral Rehabilitation, Medical University of South Carolina, 173 Ashley Ave, BSB 550E, Charleston, SC, 29425, USA.
| |
Collapse
|
4
|
Elkady M, Abdelhakim SH, Riad M. Impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity; a randomized controlled clinical trial. BMC Oral Health 2024; 24:453. [PMID: 38622629 PMCID: PMC11017642 DOI: 10.1186/s12903-024-04170-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 03/20/2024] [Indexed: 04/17/2024] Open
Abstract
BACKGROUND This clinical study was conducted aiming to evaluate the impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity. METHODS A total of 105 eligible, consenting adults were recruited. Patients had posterior teeth suffering from proximal decay with no signs of irreversible pulpitis. Patients were prepared for Class II restorations and restored with bulk-fill resin composite. Patients were randomized into three groups of 35 patients according to the number of preheating cycles for the resin composite syringe used; group I: no preheating; control group at room temperature, group II: Resin composite preheated once, and group III: Resin composite preheated ten cycles. Patients were assessed for postoperative dentin hypersensitivity using the visual analogue scale (VAS) at three-time intervals: day one, one week and by the end of one month after restorative treatment. Statistical analysis was performed; ANOVA with a single factor was used to test for significance at a p value ≤ 0.05. For nonparametric data, the Kruskal‒Wallis test was used to compare the three testing groups. Friedman's test was used to study the changes within each group. Dunn's test was used for pairwise comparisons when the Kruskal‒Wallis test or Friedman's test was significant. RESULTS The scores of the three groups through the three time intervals were almost zero except for the first day where VAS scores were recorded with maximum score of 3 for groups I and II. Groups II and III; there was no statistically significant change in hypersensitivity scores by time with P-values 0.135 and 0.368, respectively. However, for group I there was a significant difference from VAS score recorded on first day and the two following time intervals. CONCLUSION The repeated preheating cycles of bulk-fill resin composite prior to curing had no adverse effect on the patients regarding postoperative dentin hypersensitivity. This information could be of utmost significance, as the same resin composite syringe can undergo numerous preheating cycles clinically before it is completely consumed with the advantage of improvement on the handling properties. TRIAL REGISTRATION The protocol of the current study was registered at www. CLINICALTRIALS gov , with the identification number NCT05289479 on 21/03/2022. All procedures involving human participants were performed in accordance with the ethical standards of the Research Ethics Committee of the Faculty of Dentistry, Minia University, Egypt, under the approval number 73/440 on 11/09/2020.
Collapse
Affiliation(s)
- Mahmoud Elkady
- Conservative Dentistry Department, Faculty of Dentistry, Assiut University, Assiut, Egypt
| | | | - Mona Riad
- Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt.
| |
Collapse
|
5
|
Alshabib A, AlDosary K, Algamaiah H. A comprehensive review of resin luting agents: Bonding mechanisms and polymerisation reactions. Saudi Dent J 2024; 36:234-239. [PMID: 38420009 PMCID: PMC10897588 DOI: 10.1016/j.sdentj.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 03/02/2024] Open
Abstract
The field of dentistry is constantly evolving and increasingly embracing minimally invasive approaches. One such approach, which is bonding to the tooth structure, particularly enamel, has been shown to offer the most predictable outcomes. However, there are instances where significant tooth loss may limit treatment options for a restorative dentist. In these scenarios, indirect restoration might be the preferred treatment option. This literature review provides a comprehensive examination of the currently available resin luting agents and their bonding requirements. It provides valuable insights for dental professionals seeking an in-depth understanding of the current state of the field and the future prospects of dental adhesion.
Collapse
Affiliation(s)
- Abdulrahman Alshabib
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Khalid AlDosary
- Dental Department, King Abdulaziz University Hospital, King Saud University, Riyadh, Saudi Arabia
| | - Hamad Algamaiah
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
6
|
Yamaguchi S, Li H, Imazato S. Materials informatics for developing new restorative dental materials: A narrative review. FRONTIERS IN DENTAL MEDICINE 2023. [DOI: 10.3389/fdmed.2023.1123976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Materials informatics involves the application of computational methodologies to process and interpret scientific and engineering data concerning materials. Although this concept has been well established in the fields of biology, drug discovery, and classic materials research, its application in the field of dental materials is still in its infancy. This narrative review comprehensively summarizes the advantages, limitations, and future perspectives of materials informatics from 2003 to 2022 for exploring the optimum compositions in developing new materials using artificial intelligence. The findings indicate that materials informatics, which is a recognized and established concept in the materials science field, will accelerate the process of restorative materials development and contribute to produce new insights into dental materials research.
Collapse
|
7
|
Intrapulpal temperature changes during the cementation of ceramic veneers. Sci Rep 2022; 12:12919. [PMID: 35902776 PMCID: PMC9334278 DOI: 10.1038/s41598-022-17285-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 07/22/2022] [Indexed: 12/03/2022] Open
Abstract
Adhesive cementation of ceramic veneers may increase pulpal temperature (PT) due to the combined effect of heat generated by the curing unit and the exothermic reaction of the luting agent (LA). PT increase may induce pulpal damage. The aim was to determine the PT rise during the luting of ceramic veneers (CV) of different thicknesses with light- or dual-curing (LC, DC) adhesive cements as well as pre-heated restorative resin-based composites (PH-RBC). For this a thermocouple sensor was positioned in the pulp chamber of a prepared maxillary central incisor. LC, DC adhesive cements and PH-RBCs heated to 55 °C were used for the luting of CVs of 0.3, 0.5, 0.7, and 1.0 mm thicknesses. The exothermic reaction of LAs added significantly to the thermal effect of the curing unit. PT change ranged between 8.12 and 14.4 °C with the investigated combinations of LAs and ceramic thicknesses (p ≤ 0.01). The increase was inversely proportional to the increasing CV thicknesses. The highest rise (p ≤ 0.01) was seen with the polymerization of PH-RBCs. Temperature changes were predominantly influenced by the composition of the LA, which was followed by CV thickness.
Collapse
|