Yadav P, Pankuch M, McCorkindale J, Mitra RK, Rouse L, Khelashvili G, Mittal BB, Das IJ. Dosimetric evaluation of high-Z inhomogeneity with modern algorithms: A collaborative study. Phys Med 2023; 112:102649. [PMID: 37544030 DOI: 10.1016/j.ejmp.2023.102649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/12/2023] [Accepted: 07/31/2023] [Indexed: 08/08/2023] Open
Abstract
PURPOSE To evaluate modern dose calculation algorithms with high-Z prosthetic devices used in radiation treatment. METHODS A bilateral hip prosthetic patient was selected to see the effect of modern algorithms from the commercial system for plan comparisons. The CT data with dose constraints were sent to various institutions for dose calculations. The dosimetric parameters, D98%, D90%, D50% and D2% were compared. A water phantom with an actual prosthetic device was used to measure the dose using a parallel plate ionization chamber. RESULTS Dosimetric variability in PTV coverage was significant (>10%) among various treatment planning algorithms. The comparison of PTV dosimetric parameters, D98%, D90%, D50% and D2% as well as organs at risk (OAR) have large discrepancies compared to our previous publication with older algorithms (https://doi.org/10.1016/j.ejmp.2022.02.007) but provides realistic dose distribution with better homogeneity index (HI). Backscatter and forward scatter attenuation of the prosthesis was measured showing differences <15.7% at the interface among various algorithms. CONCLUSIONS Modern algorithms dose distributions have improved greatly compared to older generation algorithms. However, there is still significant differences at high-Z-tissue interfaces compared to the measurements. To ensure accuracy, it's important to take precautions avoiding placing any prosthesis in the beam direction and using type C algorithms.
Collapse
Affiliation(s)
- Poonam Yadav
- Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Mark Pankuch
- Northwestern Medicine Chicago Proton Center, 4455 Weaver Parkway, Warrenville, IL 60555, USA
| | - John McCorkindale
- Department of Radiation and Cellular Oncology, Northwestern Medicine 1000 N Westmoreland Rd, Lake Forest, IL 60045, USA
| | - Raj K Mitra
- Department of Radiation Oncology, Ochsner Health System, New Orleans, LA 7012, USA
| | - Luther Rouse
- Philips Healthcare, 100 Park Ave, Beachwood, OH 44122, USA
| | - Gocha Khelashvili
- Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Bharat B Mittal
- Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Indra J Das
- Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA.
| |
Collapse
|
2
|
Shaw M, Lye J, Alves A, Lehmann J, Sanagou M, Geso M, Brown R. Measuring dose in lung identifies peripheral tumour dose inaccuracy in SBRT audit. Phys Med 2023; 112:102632. [PMID: 37406592 DOI: 10.1016/j.ejmp.2023.102632] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/25/2023] [Accepted: 06/21/2023] [Indexed: 07/07/2023] Open
Abstract
PURPOSE Stereotactic Body Radiotherapy (SBRT) for lung tumours has become a mainstay of clinical practice worldwide. Measurements in anthropomorphic phantoms enable verification of patient dose in clinically realistic scenarios. Correction factors for reporting dose to the tissue equivalent materials in a lung phantom are presented in the context of a national dosimetry audit for SBRT. Analysis of dosimetry audit results is performed showing inaccuracies of common dose calculation algorithms in soft tissue lung target, inhale lung material and at tissue interfaces. METHODS Monte Carlo based simulation of correction factors for detectors in non-water tissue was performed for the soft tissue lung target and inhale lung materials of a modified CIRS SBRT thorax phantom. The corrections were determined for Gafchromic EBT3 Film and PTW 60019 microDiamond detectors used for measurements of 168 SBRT lung plans in an end-to-end dosimetry audit. Corrections were derived for dose to medium (Dm,m) and dose to water (Dw,w) scenarios. RESULTS Correction factors were up to -3.4% and 9.2% for in field and out of field lung respectively. Overall, application of the correction factors improved the measurement-to-plan dose discrepancy. For the soft tissue lung target, agreement between planned and measured dose was within average of 3% for both film and microDiamond measurements. CONCLUSIONS The correction factors developed for this work are provided for clinical users to apply to commissioning measurements using a commercially available thorax phantom where inhomogeneity is present. The end-to-end dosimetry audit demonstrates dose calculation algorithms can underestimate dose at lung tumour/lung tissue interfaces by an average of 2-5%.
Collapse
Affiliation(s)
- Maddison Shaw
- Australian Clinical Dosimetry Service, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia; School of Health and Biomedical Sciences, RMIT University, Melbourne, Australia.
| | - Jessica Lye
- Australian Clinical Dosimetry Service, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia; Olivia Newton John Cancer Wellness and Research Centre, Austin Health, Australia
| | - Andrew Alves
- Australian Clinical Dosimetry Service, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia
| | - Joerg Lehmann
- Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, Australia; School of Science, RMIT University, Melbourne, Australia; School of Mathematical and Physical Sciences, University of Newcastle, Australia; Institute of Medical Physics, University of Sydney, Australia
| | - Masoumeh Sanagou
- Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia
| | - Moshi Geso
- School of Health and Biomedical Sciences, RMIT University, Melbourne, Australia
| | - Rhonda Brown
- Australian Clinical Dosimetry Service, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia
| |
Collapse
|
3
|
Yamada T, Nakano H, Tanabe S, Sakai T, Tanabe S, Oka T, Sakai H, Oshikane T, Nakano T, Ohta A, Kanazawa T, Kaidu M, Ishikawa H. Verification of Qfix Encompass™ couch modeling using the Acuros XB algorithm and HypeArc™ using a high-spatial-resolution two-dimensional diode array. Med Dosim 2023; 48:261-266. [PMID: 37455221 DOI: 10.1016/j.meddos.2023.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/15/2023] [Accepted: 06/20/2023] [Indexed: 07/18/2023]
Abstract
We modeled the Qfix Encompass™ immobilization system and further verified the calculated dose distribution of the AcurosXB (AXB) dose calculation algorithm using SRS MapCHECKⓇ (SRSMC) in the HyperArc™ (HA) clinical plan. An Encompass system with a StereoPHAN™ QA phantom was scanned by SOMATOM go.Sim and imported to an Eclipse™ treatment planning system to create a treatment plan for Encompass modeling. The Encompass modeling was performed in the StereoPHAN with a pinpoint ion chamber for 6 MV and 6 MV flattening filter free (6 MV FFF), and 2 × 2 cm2, 4 × 4 cm2, and 6 × 6 cm2 irradiation field sizes. The dose calculation algorithm used was AXB ver. 15.5 with a 1.0 mm calculation grid size. The Hounsfield unit (HU) values of the Encompass modeling were set to 400, -100, -200, and -300 for Encompass, and -400, -600, -700, and -800 for the Encompass base. We evaluated the dose distribution after Encompass modeling by SRSMC using gamma analysis in 12 patients. We adopted HU values of -200 for Encompass, -800 for Encompass base for 6 MV, and -200 for Encompass and -700 for Encompass. Base for 6 MV FFF was adopted as the HU values for the Encompass modeling based on the measurement results. The proposed Encompass modeling resulted in a mean pass rate evaluation >98% for both 6 MV and 6 MV FFF when the 1%/1 mm criterion was used, demonstrating that the proposed HU value can be adopted to calculate more accurate dose distributions.
Collapse
Affiliation(s)
- Takumi Yamada
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Osaka, 565-0871, Japan.
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Tatsuya Sakai
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Shunpei Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Tetsuya Oka
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Hironori Sakai
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Tomoya Oshikane
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Toshimichi Nakano
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, 951-8122, Japan
| | - Atsushi Ohta
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Tsutomu Kanazawa
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, Niigata, 951-8520, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, 951-8122, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, 951-8122, Japan
| |
Collapse
|
4
|
Yadav P, DesRosiers CM, Mitra RK, Srivastava SP, Das IJ. Variability of Low-Z Inhomogeneity Correction in IMRT/SBRT: A Multi-Institutional Collaborative Study. J Clin Med 2023; 12:jcm12030906. [PMID: 36769553 PMCID: PMC9918128 DOI: 10.3390/jcm12030906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/14/2023] [Accepted: 01/17/2023] [Indexed: 01/25/2023] Open
Abstract
Dose-calculation algorithms are critical for radiation treatment outcomes that vary among treatment planning systems (TPS). Modern algorithms use sophisticated radiation transport calculation with detailed three-dimensional beam modeling to provide accurate doses, especially in heterogeneous medium and small fields used in IMRT/SBRT. While the dosimetric accuracy in heterogeneous mediums (lung) is qualitatively known, the accuracy is unknown. The aim of this work is to analyze the calculated dose in lung patients and compare the validity of dose-calculation algorithms by measurements in a low-Z phantom for two main classes of algorithms: type A (pencil beam) and type B (collapse cone). The CT scans with volumes (target and organs at risk, OARs) of a lung patient and a phantom build to replicate the human lung data were sent to nine institutions for planning. Doses at different depths and field sizes were measured in the phantom with and without inhomogeneity correction across multiple institutions to understand the impact of clinically used dose algorithms. Wide dosimetric variations were observed in target and OAR coverage in patient plans. The correction factor for collapsed cone algorithms was less than pencil beam algorithms in the small fields used in SBRT. The pencil beam showed ≈70% variations between measured and calculated correction factors for various field sizes and depths. For large field sizes the trends of both types of algorithms were similar. The differences in measured versus calculated dose for type-B algorithms were within ±10%. Significant variations in the target and OARs were observed among various TPS. The results suggest that the pencil beam algorithm does not provide an accurate dose and should not be considered with small fields (IMRT/SBRT). Type-B collapsed-cone algorithms provide better agreement with measurements, but still vary among various systems.
Collapse
Affiliation(s)
- Poonam Yadav
- Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Colleen M. DesRosiers
- Department of Radiation Oncology, Indiana University Health, Indianapolis, IN 46202, USA
| | - Raj K. Mitra
- Department of Radiation Oncology, Ochsner Health System, New Orleans, LA 70121, USA
| | - Shiv P. Srivastava
- Department of Radiation Oncology, Dignity Health System, Phoenix, AZ 85013, USA
| | - Indra J. Das
- Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
- Correspondence: ; Tel.: +1-312-926-6448 or +1-215-385-4523
| |
Collapse
|
5
|
Huang YY, Yang J, Liu YB. Planning issues on linac-based stereotactic radiotherapy. World J Clin Cases 2022; 10:12822-12836. [PMID: 36568990 PMCID: PMC9782937 DOI: 10.12998/wjcc.v10.i35.12822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/20/2022] [Accepted: 11/14/2022] [Indexed: 12/14/2022] Open
Abstract
This work aims to summarize and evaluate the current planning progress based on the linear accelerator in stereotactic radiotherapy (SRT). The specific techniques include 3-dimensional conformal radiotherapy, dynamic conformal arc therapy, intensity-modulated radiotherapy, and volumetric-modulated arc therapy (VMAT). They are all designed to deliver higher doses to the target volume while reducing damage to normal tissues; among them, VMAT shows better prospects for application. This paper reviews and summarizes several issues on the planning of SRT to provide a reference for clinical application.
Collapse
Affiliation(s)
- Yang-Yang Huang
- School of Nuclear Science and Engineering, East China University of Technology, Nanchang 330013, Jiangxi Province, China
- Department of Radiotherapy, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou 450014, Henan Province, China
| | - Jun Yang
- Department of Radiotherapy, The Third Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Yi-Bao Liu
- School of Nuclear Science and Engineering, East China University of Technology, Nanchang 330013, Jiangxi Province, China
| |
Collapse
|
6
|
Lobb E, Plypoo A. Limits for the therapeutic application of the analytical anisotropic algorithm in the context of ablative lung radiotherapy near the minima of lung density and tumor size. J Appl Clin Med Phys 2022; 23:e13634. [PMID: 35533238 PMCID: PMC9278665 DOI: 10.1002/acm2.13634] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 04/05/2022] [Accepted: 04/15/2022] [Indexed: 11/29/2022] Open
Abstract
Purpose To systematically investigate the performance of the analytical anisotropic algorithm (AAA) within the extremes of small tumor volumes and near‐minimum lung and tumor tissue densities in order to identify combinations of these parameters where the use of AAA could result in a therapeutically unacceptable loss of tumor coverage on an energy and fractionation‐specific basis. Methods Clinically appropriate volumetric modulated arc therapy (VMAT) treatment plans were generated with AAA for 180 unique combinations of lung density (0.05–0.30 g/cm3), tumor density (0.30–1.00 g/cm3), tumor diameter (0.5–2.5 cm), and beam energy (6 and 10 MV) and recomputed using the AcurosXB algorithm. Regression analysis was used to identify the strongest predictors of a reduction in biologically effective dose at a clinically relevant level (100 Gy BED10) for commonly utilized 1–5 fraction treatment regimens. Measurements were performed within a phantom mimicking the lower extremes of lung and tumor densities to validate AcurosXB as the approximate ground truth within these scenarios. Results The strongest predictors of a statistically significant reduction in tumor coverage were lung density ≤0.15 g/cm3, tumor diameter ≤10 mm, tumor density equal to 0.30 g/cm3, and a beam energy of 10 MV. Overestimation of clinical target volume (CTV) D95% and CTV V100Gy (BED10) by AAA can exceed 30%–40% in some scenarios. Measurements supported AcurosXB as highly accurate even for these challenging scenarios. Conclusions The accuracy of AAA rapidly diminishes near the minima of clinical lung density, particularly in combination with small tumors and when using a photon energy of 10 MV. The magnitude of the effect can be more dramatic than previously reported data suggests and could potentially compromise the ablative qualities of treatments performed within these environments, particularly with less aggressive fractionation approaches.
Collapse
Affiliation(s)
- Eric Lobb
- Department of Radiation Oncology, Ascension NE Wisconsin - St. Elizabeth Hospital, Appleton, Wisconsin, USA
| | - Ahpa Plypoo
- Department of Radiation Oncology, Ascension NE Wisconsin - St. Elizabeth Hospital, Appleton, Wisconsin, USA
| |
Collapse
|
7
|
Webster M, Tanny S, Joyce N, Herman A, Chen Y, Milano M, Usuki K, Constine L, Singh D, Yeo I. New dosimetric guidelines for linear Boltzmann transport equations through comparative evaluation of stereotactic body radiation therapy for lung treatment planning. J Appl Clin Med Phys 2021; 22:115-124. [PMID: 34783438 PMCID: PMC8664148 DOI: 10.1002/acm2.13464] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 09/30/2021] [Accepted: 10/08/2021] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To propose guidelines for lung stereotactic body radiation therapy (SBRT) when using Acuros XB (AXB) equivalent to the existing ones developed for convolution algorithms such as analytic anisotropic algorithm (AAA), considering the difference between the algorithms. METHODS A retrospective analysis was performed on 30 lung patients previously treated with SBRT. The original AAA plans, which were developed using dynamic conformal arcs, were recalculated and then renormalized for planning target volume (PTV) coverage using AXB. The recalculated and renormalized plans were compared to the original plans based on V100% and V90% PTV coverage, as well as V105%, conformality index, D2cm , Rx/Dmax , R50, and Dmin . These metrics were analyzed nominally and on variations according to RTOG and NRG guidelines. Based on the relative difference between each metric in the AAA and AXB plans, new guidelines were developed. The relative differences in our cohort were compared to previously documented AAA to AXB comparisons found in the literature. RESULTS AAA plans recalculated in AXB had a significant reduction in most dosimetric metrics. The most notable changes were in V100% (4%) and the conformality index (7.5%). To achieve equal PTV coverage, AXB required an average of 1.8% more monitor units (MU). This fits well with previously published data. Applying the new guidelines to the AXB plans significantly increased the number of minor violations with no change in major violations, making them comparable to those of the original AAA plans. CONCLUSION The relative difference found between AAA and AXB for SBRT lung plans has been shown to be consistent with previous works. Based on these findings, new guidelines for lung SBRT are recommended when planning with AXB.
Collapse
Affiliation(s)
- Matthew Webster
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Sean Tanny
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Neil Joyce
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Amy Herman
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Yuhchyau Chen
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Michael Milano
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Kenneth Usuki
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Louis Constine
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Deepinder Singh
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| | - Inhwan Yeo
- Department of Radiation OncologyUniversity of RochesterRochesterNew YorkUSA
| |
Collapse
|
8
|
Dwivedi S, Kansal S, Shukla J, Bharati A, Dangwal VK. Dosimetric evaluation of different planning techniques based on flattening filter-free beams for central and peripheral lung stereotactic body radiotherapy. Biomed Phys Eng Express 2021; 7. [PMID: 34638107 DOI: 10.1088/2057-1976/ac2f0d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 10/12/2021] [Indexed: 11/11/2022]
Abstract
This study aimed to dosimetrically compare and evaluate the flattening filter-free (FFF) photon beam-based three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) for lung stereotactic body radiotherapy (SBRT). RANDO phantom computed tomography (CT) images were used for treatment planning. Gross tumor volumes (GTVs) were delineated in the central and peripheral lung locations. Planning target volumes (PTVs) was determined by adding a 5 mm margin to the GTV. 3DCRT, IMRT, and VMAT plans were generated using a 6-MV FFF photon beam. Dose calculations for all plans were performed using the anisotropic analytical algorithm (AAA) and Acuros XB algorithms. The accuracy of the algorithms was validated using the dose measured in a CIRS thorax phantom. The conformity index (CI), high dose volume (HDV), low dose location (D2cm), and homogeneity index (HI) improved with FFF-VMAT compared to FFF-IMRT and FFF-3DCRT, while low dose volume (R50%) and gradient index (GI) showed improvement with FFF-3DCRT. Compared with FFF-3DCRT, a drastic decrease in the mean treatment time (TT) value was observed with FFF-VMAT for different lung sites between 57.09% and 60.39%, while with FFF-IMRT it increased between 10.78% and 17.49%. The dose calculation with Acuros XB was found to be superior to that of AAA. Based on the comparison of dosimetric indices in this study, FFF-VMAT provides a superior treatment plan to FFF-IMRT and FFF-3DCRT in the treatment of peripheral and central lung PTVs. This study suggests that Acuros XB is a more accurate algorithm than AAA in the lung region.
Collapse
Affiliation(s)
- Shekhar Dwivedi
- Department of Medical Physics, Tata Memorial Centre, Homi Bhabha Cancer Hospital and Research Centre, Mullanpur & Sangrur, India.,Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, India
| | - Sandeep Kansal
- Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, India
| | - Jooli Shukla
- Department of Physics, Dr Bhimrao Ambedkar University, Agra, India
| | - Avinav Bharati
- Department of Radiation Oncology, Dr Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India
| | | |
Collapse
|
9
|
Hickling SV, Veres AJ, Moseley DJ, Grams MP. Implementation of free breathing respiratory amplitude-gated treatments. J Appl Clin Med Phys 2021; 22:119-129. [PMID: 33982875 PMCID: PMC8200514 DOI: 10.1002/acm2.13253] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 03/17/2021] [Accepted: 03/25/2021] [Indexed: 12/25/2022] Open
Abstract
Purpose The purpose of this study was to provide guidance in developing and implementing a process for the accurate delivery of free breathing respiratory amplitude‐gated treatments. Methods A phase‐based 4DCT scan is acquired at time of simulation and motion is evaluated to determine the exhale phases that minimize respiratory motion to an acceptable level. A phase subset average CT is then generated for treatment planning and a tracking structure is contoured to indicate the location of the target or a suitable surrogate over the planning phases. Prior to treatment delivery, a 4DCBCT is acquired and a phase subset average is created to coincide with the planning phases for an initial match to the planning CT. Fluoroscopic imaging is then used to set amplitude gate thresholds corresponding to when the target or surrogate is in the tracking structure. The final imaging prior to treatment is an amplitude‐gated CBCT to verify both the amplitude gate thresholds and patient positioning. An amplitude‐gated treatment is then delivered. This technique was commissioned using an in‐house lung motion phantom and film measurements of a simple two‐field 3D plan. Results The accuracy of 4DCBCT motion and target position measurements were validated relative to 4DCT imaging. End to end testing showed strong agreement between planned and film measured dose distributions. Robustness to interuser variability and changes in respiratory motion were demonstrated through film measurements. Conclusions The developed workflow utilizes 4DCBCT, respiratory‐correlated fluoroscopy, and gated CBCT imaging in an efficient and sequential process to ensure the accurate delivery of free breathing respiratory‐gated treatments.
Collapse
Affiliation(s)
| | - Andrew J Veres
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| | | | - Michael P Grams
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
10
|
Sanguineti G, Pellini R, Vidiri A, Marzi S, D'Urso P, Terrenato I, Farneti A, Fuga V, Ungania S, Landoni V. Stereotactic body radiotherapy for T1 glottic cancer: dosimetric data in 27 consecutive patients. TUMORI JOURNAL 2021; 107:514-524. [PMID: 33821713 DOI: 10.1177/03008916211000440] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
AIM Because the clinical feasibility of stereotactic body radiotherapy (SBRT) for early glottic cancer (T1) is controversial, we report dosimetric results in 27 consecutive patients from a prospective phase I and II study that started in 2017. METHODS In our approach, only the parts of the true vocal cord containing cancer and those immediately adjacent are planned to be treated to 36 Gy and 30 Gy, respectively, in 3 fractions. Several dosimetric metrics for both target volumes and organs at risk were extracted from individual plans and results were compared to those achieved by other authors in a similar setting. RESULTS Proper coverage was reached at planning in 2/3 of planning treatment volume 30 Gy, but only 4 planning treatment volume 36 Gy; conversely, the maximum dose objective was met for most of the patients on either arytenoid cartilage, but this was not the case for 51.9% and 96.3% of cricoid and thyroid cartilages, respectively. Our dosimetric results are similar to if not better than those achieved by others. CONCLUSION SBRT in 3 fractions for T1 glottic lesions is dosimetrically challenging. Clinical validation is awaited.
Collapse
Affiliation(s)
- Giuseppe Sanguineti
- Department of Radiation Oncology, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Raul Pellini
- Department of Head and Neck Surgery, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Antonello Vidiri
- Department of Radiology, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Simona Marzi
- Department of Physics, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Pasqualina D'Urso
- Department of Radiation Oncology, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Irene Terrenato
- Department of Statistics, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Alessia Farneti
- Department of Radiation Oncology, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Valentina Fuga
- Department of Radiation Oncology, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Sara Ungania
- Department of Physics, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| | - Valeria Landoni
- Department of Physics, IRCCS Regina Elena National Cancer Institute, Rome, Italy
| |
Collapse
|
11
|
Howard ME, Herman MG, Grams MP. Methodology for radiochromic film analysis using FilmQA Pro and ImageJ. PLoS One 2020; 15:e0233562. [PMID: 32437474 PMCID: PMC7241712 DOI: 10.1371/journal.pone.0233562] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Accepted: 05/07/2020] [Indexed: 11/23/2022] Open
Abstract
Radiochromic film (RCF) has several advantageous characteristics which make it an attractive dosimeter for many clinical tasks in radiation oncology. However, knowledge of and strict adherence to complicated protocols in order to produce accurate measurements can prohibit RCF from being widely adopted in the clinic. The purpose of this study was to outline some simple and straightforward RCF fundamentals in order to help clinical medical physicists perform accurate RCF measurements. We describe a process and methodology successfully used in our practice with the hope that it saves time and effort for others when implementing RCF in their clinics. Two RCF analysis software programs which differ in cost and complexity, the commercially available FilmQA Pro package and the freely available ImageJ software, were used to show the accuracy, consistency and limitations of each. The process described resulted in a majority of the measurements across a wide dose range to be accurate within ± 2% of the intended dose using either FilmQA Pro or ImageJ.
Collapse
Affiliation(s)
- Michelle E. Howard
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Michael G. Herman
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Michael P. Grams
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, United States of America
| |
Collapse
|